tcl air conditioner - trade depot · pdf filetcl air-conditioner division is one of the core...
TRANSCRIPT
TCL Air Conditioner2016-2017 Catalogue
www.tcl.com
hao.tcl.com
Australia- Distributed by ENERGROUP PTY LTDTel: +61 (07) 3890 8993
Email: [email protected] Web: www.tclair.com.au
New Zealand- Distributed by Trade Depot LimitedTel: +64 (09) 2982 535
Email: [email protected]
Web: www.tradedepot.co.nz
Total RevenueIn 2015, TCL took great efforts in its brand,
product and marketing. Its sales revenue
reached 16.51 Billion USD (104.5 Billion RMB).
16.51Billion USD
Brand ValueTCL is the Most Internationalized Enterprise in
China. TCL Brand Value in 2015 is as high as
10.88 Billion USD (71.03 Billion RMB).
10.88 Billion USD
Founded in 1981, TCL is one of the largest consumer electronics enterprises in
China with a global presence.
TCL owns five listed companies:
TCL Corporation ( SZ.000100 )
TCL Multimedia Technology ( 01070.HK )
TCL Communication Technology ( 02618. HK )
TCL Display Technology ( 00334.HK )
Tonly Electronics ( 01249. HK )
01 02
T C L CorporationAn Emerging Power in China’s Wave of Globalization
TCL owns professional R&D, manufacturing, market-
ing teams and perfect after-sales service. Currently,
it has established 5 Production Bases in Zhong-
shan, Wuhan and Huizhou. The total production
capacity of TCL Air Conditioner has reached 10
Million sets per year.
Since 2001 when got involved in overseas markets,
TCL Air Conditioner has become a well known
brand with the most rapid growth in the export
sales volume. In 2015, TCL air conditioners was
sold to 165 countries and regions in the world,
and the sales Volume is more than 5 mililion sets.
Strong Industry Ability Total Sales Volume
Zhongshan 2nd Base
Zhongshan 1st Base TCL-De’Longhi JV Wuhan Base TCL-Rechi Compressor JV
TCL air-conditioner division is one of the core industries in TCL Corporation, which was
established in 1999. It is also one of the leading air conditioner manufacturers in China,
producing all kinds of residential air conditioners, commercial air conditioners, portable
air conditioners, dehumidifiers and compressors.
TCL Air Conditioner
TCL also owns the brand of
Alcatel & Thomson
03 04
TCL Wi-Fi ControlYou can easily control your air conditioner anywhere
with your mobile phone and a Wifi Connection.
(Optional for inverter)
With DRED function
A unit installed with a DRED device allows
you to participate in incentive programs
applicable to your region, such as the
ENERGEX QLD Positive Payback Program.
ICON GUIDE
Payback
Environment
Friendly
Refrigerant
High Efficient
Inner-grooved
Copper Tube
10-hour
Automatic
Power Off
±0.1℃ Precise
Temperature
Control
Quiet Operation
Independent
Dehumidification
Anti-cold Air IoniserExtra-low noise
Timer Mode Auto-protectionAuto restart
Global Power
Supply Design
(Plug)
Chord ResponseWIFI Control
Wide Voltage
Range
180°
Sine Wave
Easy Cleaning
Filter
TitanGold
The core components such as compres-
sors are purchased from top 3 brands in the
industry, so that we can provide reliable
products to customers.
Leading Components
The evaporator used in TCL TitanGold air conditioners can be
made of the TitanGold hydrophilic AL foil so that the fast-flowing
condensate can bring dusts and dirts leave on the evaporator
quickly without water and dust as well as dirt remaining on the
surface of evaporator. Due to the clean evaporator surface, the
indoor environment can be kept clean and healthy.
Self-cleaning function of TitanGold
Compared with normal air conditioners, TCL TitanGold air conditioner attenuate more slowly.
8-Year TitanGold Life, Efficient and Saving Energy
Normal Fin
TitanGold Fin
Power Consumption Comparison Energy efficiency rateRunning time
Titan-gold air conditioner
Ordinary Class-A air conditioner
0
3.63.43.23.02.82.62.4
1 1.5 2 2.5 3 3.5
NanoTiO
Compressor
Outdoor motor Electronic expansion valve
Indoor motor
4-way Valve Copper Pipe Aluminum FoilF illve Pipe
Steel
PCB
Fan
05 06
(Optional )
TCL DC motor uses magnetic force to operate the compres-
sor. This dramatically reduces energy consumption com-
pared to conventional non-inverter motors. A DC inverter AC
automatically slows down and operates at minimum suitable
capacity after reaching the set temperature.
TCL AC adopts of inverter tech and
optimized air duct & cross flow fan,
so that consumer can enjoy super
quietness
With our advanced technology, TCL AC
deliveres cool and comfortable experi-
ence more quickly than before.
TCL DC inverter AC varies the rotation speed of the
compressor, providing a precise method of maintain-
ing the set temperature. The temperature fluctuation is
controlled within ±0.5℃.
DC Inverter
Compressor
Outdoor DC motor
Electronic expansion valve
Indoor vane DC motor
Indoor DC motor
Full 5D DC Inverter (Certain models) Air Conditioner
Fast Cooling
Precise Temperature Control
High Efficiency & Saving Energy
High Efficiency
Saving Energy
Quiet Operation
Turbo
Inverter
Non-Inverter
Inverter Air Conditioner
Normal Air Conditioner
Temperature Setting
07 08
KE SeriesSplit Air Conditioner
BY SeriesSplit Air Conditioner
09 10
Specification of R410A Fixed Speed Wall SplitTAC-24CHSA/BY4 TAC-24CHSA/KC4 TAC-18CHSA/BY4TAC-12CHSA/BY4
Hi-wall split fixed speed
220-240V~50Hz
TAC-09CHSA/BY4
7000
7000
3.25
2.0
3.339
2.0
45-52
61
9.5/9.2
2100/2100
16/17
2900/3100
2250
Rotary
GMCC
1240*325*250
900*805*360
16
54
1317*422*338
1031*835*447
23
60
43/94/110
7000
7000
3.25
2.0
3.339
2.0
39-50
58
9.5/9.2
2100/2100
16/17
2900/3100
2020
Rotary
GMCC
1186×340×260
900*805*360
17
54
1265×415×338
1031*835*447
23
60
47/100/115
1033*313*202
902*650*307
13.5
45
1103*400*300
1027*705*433
18.5
49
55/124/146
898*280*200
820*605*300
9
34
995*365*298
965*650*438
12.5
37
75/160/180
898*280*200
760*552*256
9
29
995*365*298
863*605*376
12.5
32
95/198/235
1550
Rotary
GMCC
1100
Rotary
GMCC
1080
Rotary
GMCC
7.0/6.8
1500/1500
10.8/12.4
2050/2200
3.9/3.8
860/860
6.1/6.1
1150/1150
3.4/3.1
720/700
4.9/4.3
1080/1000
Cooling
Heating
Cooling
Heating
Indoor
Outdoor
Power supply
Rated current
Rated input
Max Current
Max Power input
5,000
5,000
3.30
2.0
3.270
2.0
37-48
57
3,300
3,300
3.68
2.5
3.736
2.5
36-42
58
2,700
2,700
3.66
2.5
3.944
3.0
35-42
55
W
W
W/W
W/W
dB(A)
dB(A)
A
W
A
W
mm
mm
kg
kg
mm
mm
kg
kg
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor (without pipe)
GramR410A
20'/40'GP/40'HQ
Type
Brand
Net dimensions
(W x H x D)
Net weight
Packing dimensions
(W x H x D)
Loading Capacity
Type
Rated cooling capacity
Rated heating capacity
AEER for cooling
Energy star for cooling
ACOP for heating
Energy star for heating
Model No.
Electrical Data
Compressor
Others
Refrigerant
Compressor
Gross weight
Noise Level
Due to ongoing product development, specifications are subject to change without notice.
{New design}
Due to ongoing product development, specifications are subject to change without notice.
220-240V~/50Hz/1P
8.30(3.4~11.8)
8.30(3.4~12.8)
1815(750~2450)
1815(750~2650)
14.5/14.5
3000/3000
220-240V~/50Hz/1P 220-240V~/50Hz/1P220-240V~/50Hz/1P
2.5(1.0-5.0)
2.9(1.0-6.0)
520(220-1000)
590(220-1250)
5.0/6.0
1000/1250
R410A/2.52kg
GMCC
1400/1550
1240*325*250
900*805*360
20
62
1317*422*338
1031*925*447
23
65
43/94/96
900*280*202
760*552*256
11
34
985*365*298
863*598*376
13
36
95/198/222
R410A/1100kg
GMCC
750/750
W
W
W/W
W/W
dB(A)
dB(A)
2300(1000-2800)
2600(1000-3800)
4.263
4.0
4.328
4.0
30-42
53
6850(3200-8200)
6900(3500-9000)
3.824
3.0
3.799
3.0
36-54
60
2,450
2,500
/
5.0-6.0
/
4.5-5.0
/
/
3,200
3,200
/
4.5-5.0
/
3.5-4.0
/
/
A
A
W
W
A
W
Gram
brand
m3/h
mm
mm
kg
kg
mm
mm
kg
kg
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Rated cooling capacity
Rated heating capacity
AEER for cooling
Energy star for cooling
ACOP for heating
Energy star for heating
Indoor sound pressure level
Outdoor sound power level
Rated input
Rated current
Power supply
Electrical Data
Model. 4 star 9000btu split type 3 star 24000btu split type 5 star 9000btu split type 4 star 12000btu split type
Refrigerant
Compressor brand
Indoor air circulation Cooling/heating
Max current cooling/heating
Max input cooling/heating
Cooling
Heating
Cooling
Heating
Others
Refrigerating System
Net dimensions
(W x H x D)
20'/40'GP/40'HQ Loading Capacity
Gross weight
(W x H x D)
Packing dimensions
Net weight
These two models will be available in
May,2016, the specification will be subject to
the MEPS report and update without notice in
advance
Specification of R410A Inverter high Efficiency Split
A
W
A
W
Specification of Window Type Air ConditionerTAC-CW13
18~31
TAC-CW09
230V~ 50Hz, 1Ph
4100
3600
3.28
3.30
1250
1090
5.4
4.7
1600
1400
8.5
7.5
GMCC
weiling
50-54
57-61
R410A:900
20-30
660x680x430
740x795x468
51/55
102/215/225
10~18
600×560×380
682×617×410
33/37
135/285/342
230V~ 50Hz, 1Ph
2600
2400
3.30
3.3
790
730
3.4
3.2
1400
1000
7.1
4.9
GMCC
weiling
47-51
55-59
R410A:720
Ph-V-Hz
dB(A)
g
℃
℃
m2
mm
mm
Kg
Power supply
Cooling Capacity
Heating Capacity
EER
COP
Cooling rated power input
Heating rated power input
Cooling rated current
Heating rated current
Cooling Max. input consumption
Heating Max. input consumption
Cooling Max. current
Heating Max. current
Compressor Brand
Model No.
Indoor noise level
Outdoor noise level
Refrigerant type
Operation temp
Ambient temp (cooling/heating)
Application area
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Qty’per 20’ /40’ /40'HQ
W
W
W
A
A
Fan motor Brand
W/W
18-45/-7~27
Due to ongoing product development, specifications are subject to change without notice.
Specification of R410A Normal Inverter SplitTAC-28CHSA/KCIFOTAC-24CHSA/KCIFOTAC-18CHSA/KCIFO
Hi-wall split inverter
220-240V~50Hz
TAC-12CHSA/KCIFOTAC-09CHSA/KCIFO
7800(2200~9000)
8000(2400~10000)
3.43
2.0
21℃~52℃
3.44
2.0
-15℃~24℃
38-50
60
10.2(2.6-14.9)
11.0(3.1-17.6)
2350(540-3100)
2400(640-3650)
14.9/17.6
3100/3650
R410A/2.7kg
Rotary
HIGHLY
1186x340x260
900x805x360
16
64
1265x415x338
1031x925x447
21
68
47/100/115
1186x340x260
900x805x360
16
60
1265x415x338
1031x925x447
21.5
64
47/100/115
1033x313x202
780x290x605
12
36
1103x400x300
883x412x653
17
39
70/155/185
898x280x200
760x551x256
9.5
28
995x365x298
863x361x590
13.5
31
95/198/220
800x280x183
760x551x256
8.5
28
885x366x278
863x361x590
12
31
98/203/230
mm
mm
kg
kg
mm
mm
kg
kg
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor(without pipe)
Net dimensions
(W x H x D)
Packing dimensions
(W x H x D)
Loading Capacity 20'/40'GP/40'HQ
R410A/2.15kg
Rotary
HIGHLY
R410A/1.40kg
Rotary
RECHI
R410A/1000g
Rotary
GMCC
R410A/930g
Rotary
GMCC
9.4(1.9-13.5)
9.6(1.7-14.5)
2050(400-2800)
2100(350-2900)
13.5/14.5
2800/2900
6.7(1.4-10.3)
6.9(1.4-10.9)
1480(300-2300)
1540(300-2450)
10.3/10.9
2300/2450
5.0(1.3~5.3)
5.0(1.3~7.6)
840(290~1150)
840(290~1400)
5.3/7.6
1150/1400
3.6(1.3~6.0)
3.6(1.3~6.7)
670(290~1300)
680(290~1500)
6.0/6.7
1300/1500
Cooling
Heating
Cooling
Heating
Running current
Rated input
Max current cooling/heating
Max input cooling/heating
Type
BrandCompressor
7000(2000~8000)
7500(2000~8500)
3.38
2.0
21℃~52℃
3.41
2.0
-15℃~24℃
42-49
60
5000(1500~5700)
5200(1500~6500)
3.429
2.0
21℃~52℃
3.99
3.0
-15℃~24℃
42-51
55
3200(1050~3700)
3200(1050~4500)
3.765
3.0
21℃~52℃
4.167
3.5
-15℃~24℃
35-41
53
2500(1000~3100)
2600(1000~3800)
4.126
3.5
21℃~52℃
4.43
4.0
-15℃~24℃
31-41
51
W
W
W/W
℃
W/W
℃
dB(A)
dB(A)
V
A
A
W
W
A
W
Gram
Indoor
OutdoorNoise Level
Rated cooling capacity
Rated heating capacity
Tested AEER for cooling
Energy star for cooling
Outdoor Operating Temperature Range for cooling
Tested ACOP for heating
Energy star for heating
Outdoor Operating Temperature Range for heating
Type
Model No.
Electrical Data
Refrigerating System
Others
Refrigerant
Gross weight
Net weight
Due to ongoing product development, specifications are subject to change without notice.
KC SeriesSplit Air Conditioner
G SeriesWindow Tyoe Air Conditioner
11 12
3.2kw-T1TAC-12CHSA/JAIFOM
12000btu Mining Area split inverter
3200(950-3800)
820(290-1330)
4.6(1.3-6.1)
4.11
3.5
3200(950-4200)
800(290-1700)
4.4(1.3-7.8)
4.14
3.5
1.1
1330/1700
6.1/7.8
34-45
55
R410A/1200g
4.5/1.9
900×280×202
985×365×298
14
42
17
45
95/198/222
W
W
A
W/W
W
W
A
W/W
L/h
W
A
dB(A)
dB(A)
g
MPa
mm
mm
Capacity
Input
Rated current
AEER
Star rating
Capacity
Input
Rated current
ACOP
Star rating
Moisture Removal
Max. input consumption cooling/heating
Max. current cooling/heating
Indoor noise level
Outdoor noise level
Refrigerant type (Units pre-charged for 5m pipe run)
Design pressure
Dimension(W*H*D)
Packing (W*H*D)
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
20/40GP/40HQ
Cooling
Description
Heating
Model No.
Indoor unit
Net Weight
Gross Weight
Loading Quantity
Due to ongoing product development, specifications are subject to change without notice.
Specification of R410A DC Inverter High static pressure duct
Reverse cycle & split
Remote Controller & Wall controller
TCB-60D1HRA/DV3
60
50~150
60000(18000)
5650
10.7
3.19
66000(20000)
6150
11.6
3.22
49-59
65
R410A
Mitsubishi
7.8
7.8+1.3(30M)
4.2/1.5
380-415V~3N /50Hz
342~438
10000
18.9
3/8''
3/4''
15
35
5
54
1515x492x790
1185x1390x395
77
136
1575X935X630
1270x1500x440
97
149
TCB-48D1HRA/DV
60
50~150
48000(14000)
4380
19
3.2
52000(15400)
4750
20.6
3.25
47-57
63
R410A
Mitsubishi
4.2
2.52+1.3(30M)
4.2/1.5
220-240V~/50Hz
198~253
7600
38.3
3/8''
3/4''
15
35
5
54
1200×380×590
950×1270×340
65
132
1410×445×695
1135×1380×440
66
145
TCB-42D1HRA/DV
60
50~150
42000(12000)
3750
16.3
3.20
46000(13200)
4050
17.6
3.33
47-57
63
R410A
Mitsubishi
4.2
4.2+1.3(30M)
4.2/1.5
220-240V~/50Hz/
198~253
7200
36.4
3/8''
3/4''
15
35
5
54
1200×380×590
950×1270×340
61
132
1410×445×695
1135×1380×440
66
145
TCA-26D1HRA/DV
60
50~100
26000(7600)
2350
10.2
3.23
28600(8400)
2625
11.4
3.2
45-54
60
R410A
Mitsubishi
2.52
2.52+0.6(20M)
4.2/1.5
220-240V~/50Hz/
198~253
3200
16.2
3/8''
5/8''
10
30
5
54
1200×300×800
900×790×360
45
62
1405×390×890
1031×835×447
50
70
mm
mm
kg
kg
mm
mm
kg
kg
Btu/h(W)
W
A
W/W
Btu/h(W)
W
A
W/W
dB(A)
dB(A)
Brand
kg
kg
MPa
Inches
Inches
m
m
m
g/m
V
W
A
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Type
Compressor
Charged volume(5m)
Charged volume(xxM)
Liquid
Gas
Gross weight
Packing dimensions (W x H x D)
Net dimensions (W x H x D)
Net weight
Others
Max. height drop (high head)
Max. length of connecting pipe
Max. pipe length with standard charge
Refrigerant charge with long pipe
Standard
Type
Control type
Static pressure
Cooling capacity
Heating capacity
Model No.
Design pressure
Refrigerant type/Quantity
Indoor noise level(sound pressure level)
Outdoor noise level(sound power levle)
Range
Capacity
Input
Current
AEER
Capacity
Input
Current
ACOP
Connections
Electrical Data
Connecting Pipe
Voltage Range
Max. Power
Max. Current
Power supply
Due to ongoing product development, specifications are subject to change without notice.
Pa
DUCTUnits
High Efficiency & Energy Saving SpecificallyDesigned for Mining ApplicationsFeatures TAC-12CHSA/JAIFOM
1. Customized dust proof control system for optimum performance often required in Portable
building and Mining applications.
2. Unit will start up in outside ambient temperatures not exceeding 60 degrees Celsius and can
operate in temperatures not exceeding 57 degrees Celsius.
3. Unit is designed to accommodate 20 meters pipe run for more application flexibibity.
11 12
Mining Ari Conditioner