GRID BUBBLE DOOR CALLOUT WINDOW CALLOUT BUILDING SECTION SHEET NUMBER ROOM NUMBER WALL SECTION SHEET NUMBER DETAIL NUMBER SHEET NUMBER NORTH ARROW ELEVATION CALLOUTS REVISION CALLOUT CEILING HEIGHT MATCHLINE WALL TYPE DETAIL TICK BREAK LINE KEYNOTES BUILDING ELEVATION SHEET NUMBER SLOPE ARROWS INTERIOR ELEVATIONS SHEET NUMBER SLOPE ARROWS A 0 0 POINT ELEVATION ROOM FINISH TAG SUSMP AREA ALLOCATION STEP IN SLAB FACADE ELEVATION MARKER 1 A0.0 1 A0.0 1 A0.0 1 A0.0 0' - 0" 0 T.O.WALL T.O.WALL 0 000 ROOM NAME W - 000 D - 000 X 0:12 1 A0.0 0 CEILING HGT. ROOM NAME FLR. MATERIAL SUSMP +00.00' +0'-0" +0" SLOPE MEMB. MECH. MIN. MAS. MAX. LKR. LAV. LGTH SEE STRUCTURAL DRAWINGS SSD VERIFY IN FIELD VIF METAL MTL. BETWEEN BET. FINISH FLOOR F.F. I.I.C. HGT. I.D. INT. INV. I.P.S. INSUL. H.PT. HTR. H.W. H.C. HORIZ. HDR. GR. H.B. HWD. G.D. GYP. BD. GA. GALV. G.I. F.J. GL. WATERPROOF WP. IMPACT INSULATION CLASS TONGUE AND GROOVE TERRAZZO TOP OF CURB TOP OF WALL TELEPHONE URINAL TEMPERED THROUGH TOP OF PARAPET TOP OF PLATE TREAD TYPICAL UNLESS OTHERWISE NOTED WAINSCOT WATER CLOSET WITH VERTICAL VESTIBULE WATER HEATER WOOD VINYL COMPOSITION TILE HEIGHT INTERIOR INSULATION INSIDE DIAMETER IRON PIPE SIZE INVERT HIGH POINT HOT WATER HORIZONTAL HOLLOW CORE HEATER HEADER WAINS. W/ W.C. WD. WH. U.O.N. U. VEST. V.C.T. VERT. GRADE HOSE BIBB HARDWOOD GYPSUM BOARD GARBAGE DISPOSAL FLOOR JOIST GALVANIZED GALVANIZED IRON GAUGE GLASS T.O.PL. TEMP. T.O.P. THRU T. T.O.W. TERR. T & G T.O.C. TEL. TYP. DIM. F.D. FTG. F.S. F. GL. FLUOR. F.O.F. F.O.M. F.O.S. F.O.C. F.E.C. F.G. FIN. FLR. FLRG. F.H.C. EXH. E.J. EXP. EXT. EXIST. EA. ELEV. ELEC. ENCL. D.F. D.D. DIA. D.W. DR. D.S. DWG. DET. C.W. C.T. C.YD. CONT. C.O. COL. COM. CLG. CLO. CLR. CONC. C.L. C.B. CER. C.I.P. CEM. PLASTIC LAMINATE P.L. DIMENSION REINFORCING RISER RADIUS REQUIRED SOLID CORE SHEET RESILIENT ROOF DRAIN REFRIGERATOR ROUGH OPENING ROOM STRUCTURAL SUSPENDED SPECIFICATIONS STAINLESS STEEL SIMILAR SHEATHING SQUARE STANDARD STEEL SQUARE FOOT SOUND TRANSMISSION CLASS STORAGE S.C. FLOOR DRAIN FIRE EXTINGUISHER CABINET FOOTING FIXED GLASS FLOOR SINK FLUORESCENT FACE OF MASONRY FACE OF STUD FACE OF FINISH FACE OF CONCRETE FUEL GAS FLOORING FIRE HOSE CABINET FINISH FLOOR STRUCT. SPECS. SUSP. S.S. S.T.C. S.F. STOR. SHT. SIM. SHTG. STL. STD. SQ. EXHAUST EXPANSION EXTERIOR EXISTING EXPANSION JOINT ELEVATION ELECTRICAL ENCLOSURE EACH RD. REQ'D. R.O. REF. RM. REINF. RESIL. R. RAD. MOISTURE RESISTANT MASONRY OPENING MISCELLANEOUS MANHOLE NOT TO SCALE OBSCURE NOMINAL NUMBER NOT IN CONTRACT MANUFACTURER OPPOSITE OPENING OUTSIDE DIAMETER OVERFLOW OFFICE OVEN PLASTER PLYWOOD PARTITION PAIR PROPERTY LINE/PLATE ON CENTER OBSC. DRINKING FOUNTAIN DIAMETER DOOR DIMENSION DISHWASHER DOWNSPOUT DRAWING DOOR CUBIC YARD COLD WATER CERAMIC TILE CONTINUOUS DETAIL PLYWD. PART'N CLEAN OUT COMMON CONCRETE CEILING PL. PR. PLAS. OPP. OFF. OPG. O.D. OVFL. OV. O.C. CLEAR CLOSET COLUMN CENTER LINE CATCH BASIN CERAMIC CAST IRON PIPE CEMENT N.T.S. N.I.C. NOM. NO. M.O. M.R. MISC. M.H. MFG. BD. BLK. BM. BOT. BLKG. BLDG. A.F.F. A.F.S. LOCKER MINIMUM LAVATORY LENGTH MASONRY MAXIMUM MECHANICAL MEMBRANE BLOCKING BUILDING BOARD BLOCK BEAM BOTTOM ABOVE FINISH FLOOR ABOVE FINISH SURFACE CHANGE OF USE TO EXISTING MIXED USE BUILDING FROM 30 RESIDENTIAL UNITS INTO 30 GUESTROOMS. PARTITION WALL CHANGES TO FIRST FLOOR COMMERICIAL SPACES. FIRST FLOOR AND SUBTERRANEAN PARKING LEVEL TO REMAIN. PROJECT DESCRIPTION ZONING DATA ZONING DESIGNATION: C4 - 1VL - O (COMMERCIAL ZONE) ZONING INFORMATION: ZI - 2192 WEST LA TRANSPORTATION IMPROVEMENT AND MITIGATION ZI - 2256 WESTWOOD/PICO ZI - 2452 TRANSIT PRIORITY AREA IN THE CITY OF LOS ANGELES MAX. ALLOWABLE HEIGHT: 45' - 0" EXISTING HEIGHT TO REMAIN : 45' - 0" MAX. ALLOWABLE STORIES: 3 EXISTING STORIES TO REMAIN: 3 ALLOWABLE F.A.R.: 1.5: 1 REQUIRED YARDS: FRONT NONE EXISTING TO REMAIN: 3' - 0" DEDICATION SIDE COMMERCIAL: NONE EXISTING TO REMAIN: 19' - 0" RESIDENTIAL: 5' - 0" EXISTING TO REMAIN: 5' - 0" & 12' - 1" REAR 5' - 0" COMMERCIAL: NONE EXISTING TO REMAIN: NONE RESIDENTIAL: 15' - 0" EXISTING TO REMAIN: 15' - 3" LOT AREA (PER ZIMAS): 6,602.5 SF ALLOWABLE GUEST ROOM DENSITY: 6,602.5 / 200 = 33 PROPOSED GUEST ROOMS: 30 < 33; OK ALLOWABLE BUILDABLE AREA: 100' - 0" X 135' - 0" = 13,500 SF ALLOWABLE FLOOR AREA: 13,250 X 1.5 = 20,250 SF PROPOSED FLOOR AREA: 19,695 SF < 20,250 SF PROJECT NUMBER: SHEET NUMBER: PROJECT PHASE: SHEET NAME: SHEET ISSUE DATE: S T A T E O F CA L I F O R N I A L I C E N S E D A R C H I T E C T NO. C 9412 REN. 5-31-21 _ STEPHEN M. ALBERT C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt 2/7/2020 5:40:06 PM 19520 A0.00 WESTWOOD HOTEL 1936 WESTWOOD BLVD. LOS ANGELES, CA 90025 PRELIMIARY/CONCEPT DESIGN TITLE SHEET 02/05/2020 Revision N. Revision Desc. Revision Date WESTWOOD HOTEL 1936 WESTWOOD BLVD, LOS ANGELES, CA 900325 PROJECT MAP ABBREVIATIONS SYMBOLS PROJECT DATA DIRECTORY OWNER OWNER: TESS HALAVY IBEX LIMITED CONTACT: TESS HALAVY EMAIL: [email protected] TEL: 310 - 490 - 1902 ADDRESS: 12400 WILSHIRE BLVD. SUITE 230 LOS ANGELES, CA 90025 ARCHITECT COMPANY: THE ALBERT GROUP ARCHITECTS | ARCHITAG LLP CONTACT: STEVE ALBERT MEHRZAD RAFEEI EMAIL: [email protected] [email protected] TEL: (310) 820 - 8863 ADDRESS: 2032 STONER AVE, STUDIO A LOS ANGELES, CA 90025 SHEET INDEX ARCHITECTURAL A1.00 SITE PLAN A1.01 SUBTERRANEAN FLOOR A1.02 1ST FLOOR EXIST A1.05 2ND FLOOR EXIST A1.08 3RD FLOOR EXIST A1.11 ROOF PLAN A2.01 BUILDING SECTION A2.10 BUILDING ELEVATIONS A2.11 BUILDING ELEVATIONS ACC.1 DISABLED ACCESS NOTES ACC.2 DISABLED ACCESS NOTES ACC.3 DISABLED ACCESS NOTES ACC.4 DISABLED ACCESSIBILTY DETAILS ACC.5 DISABLED ACCESSIBILITY DETAILS ACC.6 DISABLED ACCESSIBILITY DETAILS ZONING MAP A0.00 TITLE SHEET A0.01 CODE COMPLIANCE A0.02 EXITING PLANS A0.03 ACCESSIBILITY DISTRIBUTION CONTRACTOR

Upload: others

Post on 04-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

GRID BUBBLE

DOOR CALLOUT

WINDOW CALLOUT

BUILDING SECTIONSHEET NUMBER

ROOM NUMBER

WALL SECTIONSHEET NUMBER

DETAIL NUMBERSHEET NUMBER

NORTH ARROW

ELEVATION CALLOUTS

REVISION CALLOUT

CEILING HEIGHTMATCHLINE

WALL TYPE

DETAIL TICK

BREAK LINE

KEYNOTES

BUILDING ELEVATIONSHEET NUMBER

SLOPE ARROWS

INTERIOR ELEVATIONSSHEET NUMBER

SLOPE ARROWS

A 0 0

POINT ELEVATION

ROOM FINISH TAG

SUSMP AREAALLOCATION

STEP IN SLAB

FACADE ELEVATIONMARKER

1

A0.0

1

A0.0

1

A0.0

1

A0.0

0'-0"

0

T.O.WALL

T.O.WALL

0

000

ROOM NAME

W-000

D-000

X

0:12

1

A0.0

0

CEILING HGT.

ROOM NAME

FLR. MATERIAL

SUSMP

+00.00'

+0'-0"

+0"

SLOPE

MEMB.MECH.

MIN.MAS.MAX.

LKR.

LAV.LGTH

SEE STRUCTURAL DRAWINGSSSD

VERIFY IN FIELDVIF

METALMTL.

BETWEENBET.

FINISH FLOORF.F.

I.I.C.

HGT.

I.D.INT.

INV.I.P.S.

INSUL.

H.PT.

HTR.H.W.

H.C.HORIZ.

HDR.

GR.

H.B.HWD.

G.D.GYP. BD.

GA.GALV.G.I.

F.J.

GL.

WATERPROOFWP.

IMPACT INSULATION CLASS

TONGUE AND GROOVETERRAZZO

TOP OF CURBTOP OF WALL

TELEPHONE

URINAL

TEMPEREDTHROUGH

TOP OF PARAPET

TOP OF PLATETREAD

TYPICAL

UNLESS OTHERWISE NOTED

WAINSCOTWATER CLOSET

WITH

VERTICALVESTIBULE

WATER HEATERWOOD

VINYL COMPOSITION TILE

HEIGHT

INTERIORINSULATION

INSIDE DIAMETER

IRON PIPE SIZEINVERT

HIGH POINT

HOT WATERHORIZONTALHOLLOW CORE

HEATERHEADER

WAINS.W/

W.C.WD.WH.

U.O.N.U.

VEST.V.C.T.

VERT.

GRADE

HOSE BIBBHARDWOOD

GYPSUM BOARDGARBAGE DISPOSAL

FLOOR JOIST

GALVANIZEDGALVANIZED IRON

GAUGE

GLASS

T.O.PL.

TEMP.T.O.P.

THRU

T.

T.O.W.

TERR.T & GT.O.C.

TEL.

TYP.

DIM.

F.D.

FTG.

F.S.

F. GL.

FLUOR.

F.O.F.

F.O.M.F.O.S.

F.O.C.

F.E.C.F.G.

FIN.FLR.FLRG.

F.H.C.

EXH.

E.J.

EXP.EXT.

EXIST.

EA.

ELEV.ELEC.

ENCL.

D.F.D.D.DIA.

D.W.DR.

D.S.DWG.

DET.

C.W.C.T.C.YD.

CONT.

C.O.COL.COM.

CLG.CLO.CLR.

CONC.

C.L.C.B.

CER.C.I.P.

CEM.

PLASTIC LAMINATEP.L.

DIMENSION

REINFORCING

RISERRADIUS

REQUIRED

SOLID CORESHEET

RESILIENTROOF DRAIN

REFRIGERATORROUGH OPENINGROOM

STRUCTURAL

SUSPENDED

SPECIFICATIONS

STAINLESS STEEL

SIMILARSHEATHINGSQUARESTANDARDSTEEL

SQUARE FOOT

SOUND TRANSMISSION CLASS

STORAGE

S.C.

FLOOR DRAIN

FIRE EXTINGUISHER CABINET

FOOTINGFIXED GLASS

FLOOR SINKFLUORESCENT

FACE OF MASONRYFACE OF STUDFACE OF FINISH

FACE OF CONCRETE

FUEL GAS

FLOORING

FIRE HOSE CABINETFINISHFLOOR

STRUCT.

SPECS.

SUSP.S.S.

S.T.C.

S.F.

STOR.

SHT.SIM.SHTG.

STL.STD.SQ.

EXHAUST

EXPANSIONEXTERIOR

EXISTING

EXPANSION JOINT

ELEVATIONELECTRICAL

ENCLOSURE

EACH

RD.

REQ'D.

R.O.REF.

RM.

REINF.RESIL.

R.RAD.

MOISTURE RESISTANTMASONRY OPENINGMISCELLANEOUSMANHOLE

NOT TO SCALE

OBSCURE

NOMINALNUMBERNOT IN CONTRACT

MANUFACTURER

OPPOSITE

OPENING

OUTSIDE DIAMETER

OVERFLOW

OFFICE

OVEN

PLASTERPLYWOOD

PARTITION

PAIR

PROPERTY LINE/PLATE

ON CENTEROBSC.

DRINKING FOUNTAIN

DIAMETERDOOR DIMENSION

DISHWASHERDOWNSPOUTDRAWING

DOOR

CUBIC YARD

COLD WATERCERAMIC TILE

CONTINUOUS

DETAIL

PLYWD.

PART'N

CLEAN OUT

COMMONCONCRETE

CEILING

PL.

PR.

PLAS.

OPP.

OFF.OPG.

O.D.

OVFL.OV.

O.C.

CLEARCLOSET

COLUMN

CENTER LINECATCH BASIN

CERAMICCAST IRON PIPE

CEMENT

N.T.S.

N.I.C.

NOM.NO.

M.O.M.R.

MISC.M.H.

MFG.

BD.BLK.

BM.BOT.

BLKG.

BLDG.

A.F.F.A.F.S.

LOCKER

MINIMUM

LAVATORYLENGTH

MASONRYMAXIMUMMECHANICALMEMBRANE

BLOCKING

BUILDING

BOARDBLOCK

BEAMBOTTOM

ABOVE FINISH FLOORABOVE FINISH SURFACE

CHANGE OF USE TO EXISTING MIXED USE BUILDING FROM 30 RESIDENTIAL UNITS INTO 30 GUESTROOMS. PARTITION WALL CHANGES TO FIRST FLOOR COMMERICIAL SPACES. FIRST FLOOR AND SUBTERRANEAN PARKING LEVEL TO REMAIN.

PROJECT DESCRIPTION

ZONING DATA

ZONING DESIGNATION: C4-1VL-O (COMMERCIAL ZONE)

ZONING INFORMATION: ZI-2192 WEST LA TRANSPORTATION IMPROVEMENT AND MITIGATION

ZI-2256 WESTWOOD/PICOZI-2452 TRANSIT PRIORITY AREA IN THE

CITY OF LOS ANGELES

MAX. ALLOWABLE HEIGHT: 45'-0"EXISTING HEIGHT TO REMAIN : 45'-0"

MAX. ALLOWABLE STORIES: 3EXISTING STORIES TO REMAIN: 3

ALLOWABLE F.A.R.: 1.5: 1

REQUIRED YARDS:FRONT NONE

EXISTING TO REMAIN: 3'-0" DEDICATION

SIDECOMMERCIAL: NONEEXISTING TO REMAIN: 19'-0"

RESIDENTIAL: 5'-0"EXISTING TO REMAIN: 5'-0" & 12'-1"

REAR 5'-0"COMMERCIAL: NONEEXISTING TO REMAIN: NONE

RESIDENTIAL: 15'-0"EXISTING TO REMAIN: 15'-3"

LOT AREA (PER ZIMAS): 6,602.5 SF

ALLOWABLE GUEST ROOM DENSITY: 6,602.5 / 200 = 33PROPOSED GUEST ROOMS: 30 < 33; OK

ALLOWABLE BUILDABLE AREA: 100'-0" X 135'-0" = 13,500 SFALLOWABLE FLOOR AREA: 13,250 X 1.5 = 20,250 SFPROPOSED FLOOR AREA: 19,695 SF < 20,250 SF

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:06 PM

19520

A0.00

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

TITLE SHEET

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

WESTWOOD HOTEL1936 WESTWOOD BLVD, LOS ANGELES, CA 900325

PROJECT MAP

ABBREVIATIONSSYMBOLS PROJECT DATADIRECTORYOWNER

OWNER: TESS HALAVYIBEX LIMITED

CONTACT: TESS HALAVYEMAIL: [email protected]: 310-490-1902ADDRESS: 12400 WILSHIRE BLVD. SUITE 230

LOS ANGELES, CA 90025

ARCHITECT

COMPANY: THE ALBERT GROUP ARCHITECTS | ARCHITAG LLP

CONTACT: STEVE ALBERTMEHRZAD RAFEEI

EMAIL: [email protected]@TAGARCH.NET

TEL: (310) 820-8863 ADDRESS: 2032 STONER AVE, STUDIO A

LOS ANGELES, CA 90025

SHEET INDEX

ARCHITECTURAL

A1.00 SITE PLAN

A1.01 SUBTERRANEAN FLOOR

A1.02 1ST FLOOR EXIST

A1.05 2ND FLOOR EXIST

A1.08 3RD FLOOR EXIST

A1.11 ROOF PLAN

A2.01 BUILDING SECTION

A2.10 BUILDING ELEVATIONS

A2.11 BUILDING ELEVATIONS

ACC.1 DISABLED ACCESS NOTES

ACC.2 DISABLED ACCESS NOTES

ACC.3 DISABLED ACCESS NOTES

ACC.4 DISABLED ACCESSIBILTY DETAILS

ACC.5 DISABLED ACCESSIBILITY DETAILS

ACC.6 DISABLED ACCESSIBILITY DETAILS

ZONING MAP

A0.00 TITLE SHEET

A0.01 CODE COMPLIANCE

A0.02 EXITING PLANS

A0.03 ACCESSIBILITY DISTRIBUTION

CONTRACTOR

Page 2: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

ACCESSIBLIBITY REQUIREMENTS

11B-224.2 REQUIRED GUEST ROOMS WITH MOBILITY FEATURES:

TABLE 224.2 (26-50 ROOMS):

WITHOUT ROLL IN SHOWER: 2WITH ROLL IN SHOWER: 1TOTAL: 3 MOBILITY ROOMS

PROPOSED GUEST ROOMS WITH MOBILITY FEATURES:

WITHOUT ROLL IN SHOWER: 4 > 2; OKWITH ROLL IN SHOWER: 3 > 1; OKTOTAL 7 > 3; OK MOBILITY ROOMS

11B-224.3 MIN. BEDS WITH ACCESSIBLITIY CLEARANCE:

+25 BEDS: 5% MIN.# OF BEDS: 54 BEDSREQUIRED BEDS WITH CLEARANCE: 3 BEDS

PROPOSED # OF BEDS WITH CLEARANCE: 46 BEDS

11B-224. 4 REQUIRED GUEST ROOMS WITH COMMUNICATION FEATURES:

TABLE 224.4 (26-50 ROOMS) (4) ROOMS

CBC 2019 11B-224 TRANSIENT LODGING GUEST ROOMS

PARKING TABULATION

PARKING REQUIRED (LAMC 12.21.A.4(b) for Guest Rooms)

PARKING PROVIDED

FIRST 30 GUEST ROOMS 1 PER ROOM 30X1 = 30 SPACES

30 - 60 GUEST ROOMS 1 PER 2 ROOMS OVER 30 ROOMS N/A

TOTAL GUEST ROOM PARKING REQUIRED 30 SPACES

SUBTERRANEAN - VEHICULAR 32 TOTAL SPACES 23 STD, 9 CMP; 1 ADA

ADA PARKING 26-50 SPACES 2 STD ADA SPACES

LONG TERM BICYCLE PARKING NONE REQ'D1 0

SHORT TERM BICYCLE PARKING NONE RED'D1 0

FIRST FLOOR - VEHICULAR 16 TOTAL SPACES 10 STD, 6 CMP; 1 VAN ADA

TOTAL VEHICULAR PARKING PROVIDED 48 TOTAL SPACES 33 STD, 15 CMP, 2 ADA

+60 GUEST ROOMS 1 PER 3 ROOMS OVER 60 ROOMS N/A

VAN PARKING AT LEAST 1 OF ADA SPACE 1 VAN ADA SPACE

TOTAL ADA PARKING REQUIRED 2 SPACES | 1 STD, 1 VAN

ADA PARKING REQUIRED (CBC 2019 11B-208.2)

BICYCLE PARKING REQUIRED (LAMC 12.21.A.16)

TOTAL BICYCLE PARKING REQUIRED 0

PARKING REQUIRED (LAMC 12.21.A.4(c) for Commercial Buildings)

RETAIL USE 1 PER 250 SF 695 / 250 = 3 SPACES

TOTAL COMMERCIAL PARKING REQUIRED 20 SPACES

TOTAL VEHICULAR PARKING REQUIRED 30+20 = 50 SPACES

1. LAMC 12.21.A.16 (c): BUILDINGS UNDERGOING A CHANGE OF USE SHALL NOT BE REQUIRED TO PROVIDE BICYCLE PARKING.

2. LAMC 12.21.4 NEW OR EXISTING AUTOMOBILE PARKING SPACES REQUIRED [...] MAY BE REPLACED BY BICYLE PARKING AT A RATIO OF ONE AUTOMOBILE PARKING SPACE FOR EVERY FOUR REQUIRED OR NON-REQUIRED BICYLE PARKING SPACE PROVIDED.

RESTAURANT (+1,000 SF) 1 PER 100 SF 1362 / 100 = 14 SPACES

RETAIL USE 1 PER 250 SF 684 / 250 = 3 SPACES

BICYCLE PARKING PROVIDED

LONG TERM BICYCLE PARKING 4 BICYCLE PER REQ'D VEHICLE SPACE2 8 BICYCLE PARKING

ALLOWABLE AREA & HEIGHT CALCULATION

FLOOR /

LEVEL

CONSTRUCTION

TYPE

BUILDING AREA

ALLOWABLE AREA CALCULATION Aa = {At + [ NS x If ] } x SaAa = ALLOWABLE BUILDING AREA (SQUARE FEET)At = TABULAR ALLOWABLE AREA FACTOR (NS, S1, OR S13R VALUE, AS

APPLICABLE) IN ACCORDANCE WITH TABLE 506.2.NS = TABULAR ALLOWABLE AREA FACTOR IN ACCORDANCE WITHTABLE

506.2 FOR NONSPRINKLERED BUILDING (REGARDLESS OF WHETHER THE BUILDING IS SPRINKLERED).

If = AREA FACTOR INCREASE DUE TO FRONTAGE (PERCENT) AS CALCULATED IN ACCORDANCE WITH SECTION 506.3.

Sa=FOR GROUP A, E, H, I, L AND R OCCUPANCIES, HIGH-RISE BUILDINGS, AND OTHER APPLICATIONS LISTED IN SECTION 1.11 REGULATED BY THE OFFICE OF THE STATE FIRE MARSHAL, ACTUAL NUMBER OF BUILDING STORIES ABOVE GRADE PLANE, NOT TO EXCEED TWO.NO INDIVIDUAL STORY SHALL EXCEED THE ALLOWABLE AREA (AA) AS DETERMINED BY EQUATION 5-2 USING THE VALUE OF SA = 1.

TYPE VA-FS At = 36,000 SF If=0

Aa = 36,000 SF

COMMERCIAL / A-2*, M1ST FL

TYPE VA-FS

RESIDENTIAL / R-1

2ND & 3RD FL

2019 CBC, SECTION 504&506

HEIGHT STORY

470' NS = 12,000 SF

Sa=1

ALLOWABLE AREA PER STORY

ALLOW

ABLE

EXIST

ING

ALLOW

ABLE

EXIST

ING

45'

TABLE 504.4TABLE 504.3

3

ALLOWABLE PROPOSED

SEC 506

Sa=2

TOTAL ALLOWABLE AREA Aa = [36,000] x 2

Aa = 72,000 SF

At = 34,500 If=0

Aa = 34,500

NS = 11,500

Sa=1

ALLOWABLE AREA PER STORY

Sa=1

TOTAL ALLOWABLE AREA

Aa = 34,500

2ND FLR= 8,212 SF

3RD FLR= 8,229 SF

TOTAL AREA= 16,441 SF

TOTAL AREA= 3,254 SF

370' 45' 3

1ST FLR= 3,254 SF

*ALLOWABLE HEIGHT, STORY, & BLDG AREA BASED ON MORE RESTRICTIVE A-2 OCCUPANCY

APPLICABLE BUILDING CODE:2019 CALIFORNIA BUILDING CODE WITH 2017 L.A. CITY AMENDMENTS2019 CALIFORNIA CODE OF REGULATIONS TITLE 24 PART 11 WITH L.A.

CITY AMENDMENTS2019 CALIFORNIA ELECTRICAL CODE WITH 2017 L.A. CITY AMENDMENTS2019 CALIFORNIA MECHANICAL CODE WITH 2017 L.A. CITY

AMENDMENTS2019 CALIFORNIA PLUMBING CODE WITH 2017 L.A. CITY AMENDMENTS2000 EDITION OF PLANNING AND ZONING CODE WITH CURRENT

AMENDMENTS

PROPOSED USE / OCCUPANCY TYPE:GUEST ROOM UNITS (R-1) RESTAURANT (A-2)RETAIL (M)PARKING & STORAGE (S-2)

PROPOSED CONSTRUCTION TYPE:V-A - 1ST FLOORV-A - 2ND & 3RD FLOOR*FULLY SPRINKLERED* (NFPA-13) TO ALL BUILDING AREA

PROPOSED GUEST ROOM DENSITY: 30 UNITS

EXISTING NO. OF STORIES: 3

PROJECT DATA & CODE SUMMARY

1. MAXIMUM EXIT ACCESS TRAVEL DISTANCE FOR R-2 OCCUPANCY, PER TABLE 1016.1, IS 250' WITH AN AUTOMATIC SPRINKLER SYSTEM

2. MAXIMUM EXIT ACCESS TRAVEL DISTANCE FOR S-2 OCCUPANCY, PER TABLE 1016.1, IS 400' WITH AN AUTOMATIC SPRINKLER SYSTEM

3. NOTED STAIR WIDTHS ARE TAKEN FROM INSIDE OF STINGER TO INSIDE OF STRINGER, NOT THE CLEAR WIDTH BETWEEN HANDRAILS, TYPICAL UNLESS OTHER NOTED.ALL PORTIONS OF THE MEANS OF EGRESS SHALL COMPLY WITH SECTION 1003 OF THE 2016 CBC.

4. REGARDLESS OF THE OCCUPANT LOAD SERVED, ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE.

5. CONTRACTOR SHALL CHALK OUT ALL NON-BEARING WALLS PRIOR TO FRAMING AND CONTACT OWNER/ARCHITECT FOR FIELD INSPECTION OF ADA CLEARANCES PRIOR TO FRAMING.

6. ALL DOORS TO BE A MINIMUM OF 3'-0" WIDE x 6'-8" HIGH MINIMUM (U.O.N., SEE PLANS FOR LARGER EGRESS WIDTHS) EGRESS DOOR, SEE SCHEDULE FOR FURTHER INFORMATION (HEIGHTS AND WIDTHS MAY VARY).

7. ALONG EGRESS PATH, MAINTAIN 44" MINIMUM WIDTH AT INTERIOR AND 48" MINIMUM AT EXTERIOR (U.O.N. FOR LARGER OCCUPANT LOADS) CLEAR WIDTH x 7'-6" MIN. CLEAR VERTICAL CLEARANCE CONTINUOUS.

8. PANIC HARDWARE SHALL BE INSTALLED ON ALL DOORS OPENING IN THE DIRECTION OF EGRESS TRAVEL.

9. THE SEPARATION DISTANCE OF THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL NOT BE LESS THAN ONE THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREAS SERVED, PER SECTION 1015.2.1 OF 2012 CBC, EXCEPTION 2.

EGRESS & ADA

CODE COMPLIANCE GENERAL NOTES

ACCESSIBLE ROOM COUNT & DISTRIBUTION

MOBILITY

0

ROOM TYPE

NO BALCONY

1W/ BALCONY

2 DBL

0

2

4

COUNT

3

2

11

8

6

KING

2 QUEEN

NO BALCONY

W/ BALCONY

NO BALCONY

30 7

TOTAL 5 1

TOTAL

TOTAL

19 2

COMM. DEVICE

1

1

1

1

1

2

2

5

CBC 2019 11B-224.1.3 RANGE OF ACCOMMODATIONS

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:07 PM

19520

A0.01

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

CODE COMPLIANCE

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

ROOM SCHEDULE

Count Name

7 ACC. BATH

1 BACK OF HOUSE

1 BAR

3 KING

2 KING + BALC.

1 KITCHEN

2 LOBBY

1 PARKING

1 RESTAURANT

2 RETAIL

3 STAIR A

3 STAIR B

1 TRASH & RECYCLING

6 TWO DOUBLE

11 TWO QUEEN

8 TWO QUEEN + BALC.

Page 3: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UPUP

3' - 8"3' -

8"

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

498 SF

TWO QUEEN +

BALC. R-1

110

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

404 SF

TWO QUEENR-1

111

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

467 SF

TWO QUEENR-1

112

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

473 SF

TWO QUEENR-1

113

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

453 SF

KINGR-1

114

3

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

404 SF

TWO QUEENR-1

115

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

403 SF

TWO DOUBLER-1

116

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

451 SF

TWO DOUBLER-1

117

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

396 SF

TWO DOUBLER-1

118

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

462 SF

KING + BALC.R-1

119

3

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

432 SF

TWO QUEEN +

BALC. R-1

120

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

443 SF

TWO QUEEN +

BALC. R-1

121

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

463 SF

TWO QUEEN +

BALC. R-1

122

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

493 SF

TWO QUEEN +

BALC. R-1

123

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

488 SF

TWO QUEEN +

BALC. R-1

124

4

1

200

EXIT SEPARATIO

N

82' - 7 25/32"

4' - 8"

EXIT ACCESS = 151'-9"

EXIT ACCESS = 132'-10"

EXIT ACCESS = 123'-9"

EX

IT A

CC

ES

S =

116'-5"

TOTAL FLOOR OCCUPANCY = 58

EGRESS ACCESS PATH

ACCESSIBLE EGRESS PATH

MAX LOAD:

REQ'D WIDTH:

FLOOR LOAD:

PROV'D WIDTH:

DOOR WIDTH:

STAIR A58

44"

58

44"

36"

MAX LOAD:

REQ'D WIDTH:

FLOOR LOAD:

PROV'D WIDTH:

DOOR WIDTH:

STAIR B58

44"

58

44"

36"

CBC 1017.2 EXIT ACCESS TRAVEL DISTANCE:

OCCUPANCY A, M, R = 250'-0" MAX. OCCUPANCY S-2 = 400'-0" MAX.

3' -

8"

3' - 8"

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

438 SF

TWO QUEENR-1

139

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

380 SF

TWO QUEENR-1

140

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

380 SF

TWO QUEENR-1

141

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

383 SF

TWO QUEEN +

BALC. R-1

138

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

448 SF

KING + BALC.R-1

137

3

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

501 SF

TWO QUEEN +

BALC. R-1

136

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

421 SF

TWO DOUBLER-1

135

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

451 SF

TWO DOUBLER-1

134

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

403 SF

TWO DOUBLER-1

133

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

404 SF

KINGR-1

132

3

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

405 SF

KINGR-1

131

3

1

200

EXIT SEPARATIO

N

82' - 8 25/32"

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

430 SF

TWO QUEENR-1

127

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

357 SF

TWO QUEENR-1

128

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

399 SF

TWO QUEENR-1

129

4

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

409 SF

TWO QUEENR-1

130

4

1

200

EXIT ACCESS = 143'-3"

EX

IT A

CC

ES

S =

124'-1"

TOTAL FLOOR OCCUPANCY = 57

EGRESS ACCESS PATH

ACCESSIBLE EGRESS PATH

MAX LOAD:

REQ'D WIDTH:

FLOOR LOAD:

PROV'D WIDTH:

DOOR WIDTH:

STAIR A57

44"

57

44"

36"

MAX LOAD:

REQ'D WIDTH:

FLOOR LOAD:

PROV'D WIDTH:

DOOR WIDTH:

STAIR B57

44"

57

44"

36"

CBC 1017.2 EXIT ACCESS TRAVEL DISTANCE:

OCCUPANCY A, M, R = 250'-0" MAX. OCCUPANCY S-2 = 400'-0" MAX.

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

10893 SF

PARKINGS-2

7

55

2

200

EXIT SEPARATIO

N

105' - 3"

EXIT ACCESS = 112'-7" < 250' -0"; OK

EXIT ACCESS = 99'-5" < 250'-0"; OK

MAX LOAD:

REQ'D WIDTH:

FLOOR LOAD:

PROV'D WIDTH:

DOOR WIDTH:

STAIR A61

44"

61

44"

36"

MAX LOAD:

REQ'D WIDTH:

FLOOR LOAD:

PROV'D WIDTH:

DOOR WIDTH:

STAIR B61

44"

61

44"

36"

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

96 SF

STORAGES-2

10

1

1

300

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

77 SF

RoomS-2

11

1

1

300

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

135 SF

RoomS-2

12

1

1

300

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

157 SF

LT BIKE STORAGES-2

6

1

1

300

TOTAL FLOOR OCCUPANCY = 61

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

366 SF

ELEC.

TRANSFORMER

VAULT

S-2

1

2

1

300

CBC 1017.2 EXIT ACCESS TRAVEL DISTANCE:

OCCUPANCY A, M, R = 250'-0" MAX. OCCUPANCY S-2 = 400'-0" MAX.

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

349 SF

LOBBYR-1

163

24

15

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

994 SF

RESTAURANTA-2

107

63

2

15

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

695 SF

RETAILM

108

12

1

60

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

684 SF

RETAILM

162

12

1

60

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

249 SF

BACK OF HOUSER-1

164

2

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

5447 SF

PARKINGS-2

165

28

1

200

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

88 SF

TRASH &

RECYCLING S-2

166

1

1

300

EXIT ACCESS = 43'-4"

EXIT ACCESS = 43'-4"

EXIT ACCESS = 77'-6"

EXIT ACCESS = 37'-10"

EX

IT A

CC

ES

S =

123'-10"

EXIT ACCESS = 30'-9"EXIT ACCESS = 131'-0"

MAX LOAD:

REQ'D WIDTH:

FLOOR LOAD:

PROV'D WIDTH:

DOOR WIDTH:

STAIR A0

44"

61

44"

36"

MAX LOAD:

REQ'D WIDTH:

FLOOR LOAD:

PROV'D WIDTH:

DOOR WIDTH:

STAIR B0

44"

61

44"

36"

TOTAL FLOOR OCCUPANCY = 170

CBC 1017.2 EXIT ACCESS TRAVEL DISTANCE:

OCCUPANCY A, M, R = 250'-0" MAX. OCCUPANCY S-2 = 400'-0" MAX.

TYPE:

LOAD FACTOR:

EXITS REQUIRED:

TOTAL OCCUPANTS:

368 SF

KITCHENA-2

173

2

1

200

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:11 PM

19520

A0.02

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

EXITING PLANS

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/16" = 1'-0"EXIT ROUTE 2ND FLOOR 1

SCALE:

1/16" = 1'-0"EXIT ROUTE 3RD FLOOR 2

SCALE:

1/16" = 1'-0"EXIT ROUTE SUBTERRANEAN FLOOR 3

SCALE:

1/16" = 1'-0"EXIT ROUTE 1ST FLOOR 4

Page 4: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

TWO QUEEN +

BALC.

TWO QUEEN

TWO QUEEN

TWO QUEEN

KING TWO QUEEN

TWO DOUBLE

TWO DOUBLE

TWO DOUBLE

KING + BALC.

TWO QUEEN +

BALC.

TWO QUEEN +

BALC.

TWO QUEEN +

BALC.TWO QUEEN +

BALC.

TWO QUEEN +

BALC.

COMMUNICATION FEATURES

MOBILITY FEATURES

TWO QUEEN

TWO QUEEN

TWO QUEEN

TWO QUEEN

KING

KING

TWO DOUBLE

TWO DOUBLE

TWO DOUBLE

TWO QUEEN +

BALC.

KING + BALC.

TWO QUEEN +

BALC.

TWO QUEEN

TWO QUEEN

TWO QUEEN

COMMUNICATION FEATURES

MOBILITY FEATURES

CBC 11B-224.5: ONE GUEST ROOM REQUIRED TO PROVIDE MOBILITY FEATURES SHALL ALSO PROVIDE COMMUNICATION FEATURES

ACCESSIBLE ROOM COUNT & DISTRIBUTION

MOBILITY

0

ROOM TYPE

NO BALCONY

1W/ BALCONY

2 DBL

0

2

4

COUNT

3

2

11

8

6

KING

2 QUEEN

NO BALCONY

W/ BALCONY

NO BALCONY

30 7

TOTAL 5 1

TOTAL

TOTAL

19 2

COMM. DEVICE

1

1

1

1

1

2

2

5

CBC 2019 11B-224.1.3 RANGE OF ACCOMMODATIONS PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:14 PM

19520

A0.03

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

ACCESSIBILITY

DISTRIBUTION

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/16" = 1'-0"ACC. 2ND FLOOR 1

SCALE:

1/16" = 1'-0"ACC. 3RD FLOOR 2

ROOM SCHEDULE

Count Name

7 ACC. BATH

1 BACK OF HOUSE

1 BAR

3 KING

2 KING + BALC.

1 KITCHEN

2 LOBBY

1 PARKING

1 RESTAURANT

2 RETAIL

3 STAIR A

3 STAIR B

1 TRASH & RECYCLING

6 TWO DOUBLE

11 TWO QUEEN

8 TWO QUEEN + BALC.

Page 5: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UPUP

WES

TWO

OD

BLV

D

ADJACENT BUILDING

ADJACENT BUILDING

N

100' -

0"

135' - 0"

EXIST DED.3' - 0"

116' - 8"

99' -

8"

5' - 0"

PARKING ENTRANCE

15' - 1"

RAMP DN TO SUB. PARKING

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:15 PM

19520

A1.00

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

SITE PLAN

02/05/2020

SCALE:

1/8" = 1'-0"SITE PLAN 1

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

Page 6: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

UP

1

1

1.7 7

8

9

9

AA

G

HH

B B

2 4 5

D

F

3 6

C

E

28' - 8" 29' - 8" 20' - 6" 47' - 9" 5' - 2"

131' - 9"

28' -

8"

24' -

0"

29' -

5"

17' -

7"

99' -

8"

19' -

0"

19' -

6"

19' -

4"

17' -

7"

19' - 9" 37' - 2" 25' - 2" 30' - 1" 19' - 7"

11' -

6"

14' -

10"

24' -

3"

P1 P2 P3 P4 P5 P6 P7 P8 P9 P10

P11

P12

P13

P14

P15

P16

P22

P23

P17 P18C1

D.2

A.2

G.3

A3.00

4

WES

TWO

OD

BLV

D

N

0' - 2" EXIST. DED.3' - 0"

135' - 0"

100' -

0"

23 STANDARD9 COMPACT

TOTAL 32 SPACES

D.9

D.10

ELEC.

TRANSFORMER

VAULT

22' - 9"

C7

C2 C3 C4

C5C6P19C8P20

P21

25' -

0"

25' -

0"

C9

157 SF

LT BIKE

STORAGE

6

10893 SF

PARKING

7

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:16 PM

19520

A1.01

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

SUBTERRANEAN FLOOR

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"00 EXIST SUBTERRANEAN 1

Page 7: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

UPUP

UP

1

1 1.5

1.7

1.7

2.3

2.3

4.3

4.3

5.1

5.1

7

7

8

8

9

9

AA

B.2

GG

HH

B

B.6

D.1

B.4

D

E

15' - 1" 4' - 8" 14' - 9" 29' - 4" 17' - 0" 31' - 4" 14' - 5" 8' - 3"

126' - 7"

19' -

0"

32' -

6"

26' -

2"

22' -

0"

19' - 9" 14' - 9" 29' - 4" 17' - 0" 31' - 4" 14' - 5" 5' - 2"

19' -

0"

15' -

10"

15' -

9"

15' -

9"

15' -

9"

17' -

7"

99' -

8"D.2

P10

P9

P7

P6

P5

P4

P1

P2

P3

C4

C5

C6

C1

C2

C3

WES

TWO

OD

BLV

D

N

D.9

D.10

695 SF

COMMERCIAL

3

684 SF

COMMERCIAL

4

5' - 0"

3' - 0"

1721 SF

RESTAURANT

2

KITCHEN

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:17 PM

19520

A1.02

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

1ST FLOOR EXIST

02/05/2020

SCALE:

1/8" = 1'-0"EXIST 1ST FLOOR 1

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

KEYNOTES

Key Value Keynote Text

Page 8: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

UPUP

UP

1

1 1.5

1.7

1.7

2.3

2.3

4.3

4.3

5.1

5.1

7

7

8

8

9

9

AA

B.2

GG

HH

B

B.6

D.1

B.4

D

E

D.2

15' - 1" 4' - 8" 14' - 9" 29' - 4" 17' - 0" 31' - 4" 14' - 5" 8' - 3"

126' - 7"

19' -

0"

32' -

6"

26' -

2"

22' -

0"

19' - 9" 14' - 9" 29' - 4" 17' - 0" 31' - 4" 14' - 5" 5' - 2"

19' -

0"

15' -

10"

15' -

9"

15' -

9"

15' -

9"

17' -

7"

99' -

8"

P10

P9

P7

P6

P5

P4

P1

P2

P3

C4

C5

C6

C1

C2

C3

WES

TWO

OD

BLV

D

N

D.9

D.10

D1

D1

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:18 PM

19520

A1.03

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

1ST FLOOR DEMO

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"DEMO 1ST FLOOR 1

KEYNOTES

Key Value Keynote Text

D1 REMOVE EXISTING PARTITION WALL

Page 9: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

UPUP

UP

A2.101

A2.10

A2.11

A2.11

1

2

2

1

1 1.5

1.7

1.7

2.3

2.3

4.3

4.3

5.1

5.1

7

7

8

8

9

9

AA

B.2

GG

HH

B

B.6

D.1

B.4

D

E

1

A2.01

2

A2.01

D.2

15' - 1" 4' - 8" 14' - 9" 29' - 4" 17' - 0" 31' - 4" 14' - 5" 8' - 3"

126' - 7"

19' -

0"

32' -

6"

26' -

2"

22' -

0"

19' - 9" 14' - 9" 29' - 4" 17' - 0" 31' - 4" 14' - 5" 5' - 2"

19' -

0"

15' -

10"

15' -

9"

15' -

9"

15' -

9"

17' -

7"

99' -

8"

P10

P9

P7

P6

P5

P4

P1

P2

P3

C4

C5

C6

C1

C2

C3

WES

TWO

OD

BLV

D

N

994 SF

RESTAURANT

107

695 SF

RETAIL

108

10 STANDARD6 COMPACT

16 TOTAL SPACES

D.9

D.10

7' -

11"

A3.00

1

684 SF

RETAIL

162

349 SF

LOBBY

163

BACK OF HOUSE

P8

5447 SF

PARKING

165

88 SF

TRASH &

RECYCLING

166

368 SF

KITCHEN

173

01

04

04

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:19 PM

19520

A1.04

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

1ST FLOOR PROPOSED

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"PROPOSED 1ST FLOOR 1

KEYNOTES

Key Value Keynote Text

01 NEW STOREFRONT SYSTEM

04 NEW WALLS

Page 10: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

UP

UP

UP

1.5 8

AA

G

H

B

3 6

36' - 11" 15' - 3" 15' - 3" 18' - 3" 25' - 10"

15' - 3" 111' - 6" 5' - 3"

3' - 0"

A.2A.2

G.3G.3

12' -

1"

82' -

9"

5' -

0"

13' -

4"

16' -

3"

13' -

3"

13' -

3"

13' -

3"

13' -

5"

26' - 8" 15' - 3" 14' - 0" 2' - 6" 14' - 0" 14' - 0" 2' - 6" 13' - 4" 4' - 0" 4' - 0" 4' - 6"2' - 0"

15' - 3" 110' - 3"

1' - 3"

5' - 3"

WES

TWO

OD

BLV

D

N

D.9

D.10

28' -

7"

20' -

2"

21' -

5"

12' -

7"

7' -

1"

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:21 PM

19520

A1.05

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

2ND FLOOR EXIST

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"EXIST 2ND FLOOR 1

KEYNOTES

Key Value Keynote Text

Page 11: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

UP

UP

UP

1.5 8

AA

G

H

B

3 6

A.2A.2

G.3G.3

36' - 11" 15' - 3" 15' - 3" 18' - 3" 25' - 10"

15' - 3" 111' - 6" 5' - 3"

3' - 0"

12' -

1"

82' -

9"

5' -

0"

13' -

4"

16' -

3"

13' -

3"

13' -

3"

13' -

3"

13' -

5"

26' - 8" 15' - 3" 14' - 0" 2' - 6" 14' - 0" 14' - 0" 2' - 6" 13' - 4" 4' - 0" 4' - 0" 4' - 6"2' - 0"

15' - 3" 110' - 3"

1' - 3"

5' - 3"

WES

TWO

OD

BLV

D

N

D.9

D.10

D7

D7

D7

D7

D7

D7

D7 D7 D7

D7

D7

D7

D7D7D7

D1

D3

D3

D3

D3

D2D2

D1

D8

D9 D9

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:22 PM

19520

A1.06

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

2ND FLOOR DEMO

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"DEMO 2ND FLOOR 1

KEYNOTES

Key Value Keynote Text

D1 REMOVE EXISTING PARTITION WALL

D2 PARTIAL REMOVAL OF PARTITION WALL

D3 REMOVE EXISTING PLUMBING FIXTURES

D7 REMOVE EXISTING KITCHEN FIXTURES,APPLIANCES & CASEWORK. PATCH &REPAIR WALL & FLOORING AS NEEDED

D8 REMOVE EXISTING DOOR; PATCH INOPENING TO MATCH SURROUNDING WALL

D9 EXISTING UNIT DOOR TO BE RELOCATED;PATCH WALL TO RETAIN FIRE RATING

Page 12: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

UP

UP

UP

A2.101

A2.10

A2.11

A2.11

1

2

2

1.5 8

AA

G

H

B

3 6

1

A2.01

2

A2.01

A.2A.2

G.3G.3

36' - 11" 15' - 3" 15' - 3" 18' - 3" 25' - 10"

15' - 3" 111' - 6" 5' - 3"

3' - 0"

12' -

1"

82' -

9"

5' -

0"

13' -

4"

16' -

3"

13' -

3"

13' -

3"

13' -

3"

13' -

5"

26' - 8" 15' - 3" 14' - 0" 14' - 0" 2' - 6" 13' - 4" 4' - 0" 4' - 0" 4' - 6"2' - 0"

15' - 3" 110' - 3"

1' - 3"

5' - 3"

WES

TWO

OD

BLV

D

N

A1.20

1

8' -

6"

16' - 6"

TWO QUEEN +

BALC.

TWO QUEEN

TWO QUEEN

TWO QUEEN

KING

TWO QUEEN

TWO DOUBLE TWO DOUBLE TWO DOUBLE

KING + BALC.

TWO QUEEN +

BALC.

TWO QUEEN +

BALC.

TWO QUEEN +

BALC.TWO QUEEN +

BALC.

TWO QUEEN +

BALC.

ACC. BATH

D.9

D.10

ACC. BATH ACC. BATH

A1.20

2

A3.00

2

19' -

10"

14' -

11"

201 202

E E

205203

204 206

NEW ENTRY COVER

0404

0404

04

06 06

0404

E

E

06

06

06 06

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:23 PM

19520

A1.07

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

2ND FLOOR PROPOSED

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"PROPOSED 2ND FLOOR 1

KEYNOTES

Key Value Keynote Text

04 NEW WALLS

06 UPDATE EXISTING THRESHOLD TOACCESSIBLE CODE COMPLIANCE ASNEEDED

Page 13: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

UPUPUP

1

1.5

1.5

8

8

B

B.6

A.2

G.3G.3

36' - 11" 15' - 3" 15' - 3" 18' - 3" 25' - 10"

13' -

4"

16' -

2"

13' -

4"

13' -

3"

13' -

3"

13' -

5"

26' - 8" 15' - 3" 14' - 0" 2' - 6" 14' - 0" 14' - 0" 2' - 6" 13' - 4" 4' - 0" 4' - 0"

1' - 3"

WES

TWO

OD

BLV

D

N

DBL HT SPACE

DBL HT SPACE

DBL HT SPACE

DBL HT SPACE

D.9

D.10

OPEN TO BELOW

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:24 PM

19520

A1.08

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

3RD FLOOR EXIST

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"EXIST 3RD FLOOR 1

KEYNOTES

Key Value Keynote Text

Page 14: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

1

1.5

1.5

8

8

B

B.6

A.2

G.3G.3

D.9

D.10

D7

D7

D7

D7

D7

D7

D7 D7

D7

D7

D7

D7D7D7

D7

D1 D1

D1D1D1

D3

D3

D3

D1

D8D8

D8

D1

D9 D9

D9 D9

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:26 PM

19520

A1.09

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

3RD FLOOR DEMO

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"DEMO 3RD FLOOR 1

KEYNOTES

Key Value Keynote Text

D1 REMOVE EXISTING PARTITION WALL

D3 REMOVE EXISTING PLUMBING FIXTURES

D7 REMOVE EXISTING KITCHEN FIXTURES,APPLIANCES & CASEWORK. PATCH &REPAIR WALL & FLOORING AS NEEDED

D8 REMOVE EXISTING DOOR; PATCH INOPENING TO MATCH SURROUNDING WALL

D9 EXISTING UNIT DOOR TO BE RELOCATED;PATCH WALL TO RETAIN FIRE RATING

Page 15: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

UP

UP

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

1

1.5

1.5

8

8

B

B.6

1

A2.01

2

A2.01

A.2

G.3G.3

D.9

D.10

TWO QUEEN

TWO QUEEN

TWO QUEEN

TWO QUEEN

KING

KING TWO DOUBLE TWO DOUBLE

TWO QUEEN +

BALC.

KING + BALC.

TWO QUEEN +

BALC.

TWO QUEEN

TWO QUEENTWO QUEEN

TWO DOUBLE

ACC. BATH ACC. BATH

ACC. BATH

A3.00

3

OPEN TO BELOW

17' -

2"

16' -

8"

A1.20

1Sim

A1.20

3

301 302

E E

305304

303 306

308 309

307

04 04

0404

06 06

0404

06

E E

E

06

04

04

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:27 PM

19520

A1.10

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

3RD FLOOR PROPOSED

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"PROPOSED 3RD FLOOR 1

KEYNOTES

Key Value Keynote Text

04 NEW WALLS

06 UPDATE EXISTING THRESHOLD TOACCESSIBLE CODE COMPLIANCE ASNEEDED

Page 16: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UPUP

1

A2.01

2

A2.01

WES

TWO

OD

BLV

D

N

ENCLOSE EXISTING COURTYARD

NEW WALL

EXISTING WALL TO REMAIN

PLAN LEGEND

EXISTING TO BE REMOVED

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:28 PM

19520

A1.11

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

ROOF PLAN

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"ROOF 1

KEYNOTES

Key Value Keynote Text

Page 17: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

4.3

G

B.4

F

3

E

G.3

2' - 0" 4' - 7" 7' - 2"

8' -

6"

18' -

5"

R 2' - 6"

+/-

28' -

0"

A1.20

4

36"X

48"

36"X

48"

36"X

48"

DO

UB

LE

DO

UB

LE

15' - 3"

0404

02

05

05

05

06

5.1

A

B.2

B

B.6

5

6

A.2

36"X

48"

36"X

48"

36"X

48"

QU

EE

NQ

UE

EN

A1.20

5

R 2' - 6"

10' -

6"

22' -

2"

+/-

33' -

2"

2' - 0"12' - 3"

+/- 14' - 9"

BALCONY

04

05

05

05

06

06

7 8 9

B.6

D.1

C

D.9

D.10

4' - 2 1/2" 13' - 4"

6' -

0"

2' - 0"

A1.20

4Sim

R 2' - 6"

36"X48" 36"X48" 36"X48"

36"X48" 36"X48"

QUEEN QUEEN

KING

7' -

2"

4' -

6"

5' -

6"

+/- 27' - 0 1/2"

8' - 6"

17' -

5"

16' -

11"

BALCONY

BALCONY

R 2' - 6"

0404

05 05

05 05 05

06

06

LEGEND

1-HOUR FIRE BARRIER (MIN REQ'D)

2-HOUR FIRE BARRIER (MIN REQ'D)

PLENUM/SOFFIT @ 8'-0" (7'-6" MIN.)

A4 0WALL TYPE TAG, TYP U.N.O. REFER TO AD.10

BATHROOM EXHAUST: ENERGY STAR COMPLIANT, DUCTED TO TERMINATE OUTSIDE THE BUILDING. FANS NOT FUNCTIONING AS A COMPONENT OF A WHOLE UNIT VENTILATION SYSTEM MUST BE HUMIDITY CONTROLLEDSMOKE DETECTOR [PER CBC 907.2.11.2]S

CARBON MONOXIDE DETECTOR [PER CBC 420.6]C

24" EXT18" INT

UNIT DOOR MENUEVERING CLEARANCES

PRIMARY | EXTERIOR

60

"4

8"

12"

18"

INTERIOR | W/IN GUEST ROOM

42

"4

2"

B.4

E

8' -

6"

1' -

5"

3' -

0"

1' -

6"

7' - 2"

2' - 1"

1' -

6"

3' -

0"

A.2

1' -

5"

5' -

0"

1' -

6"

10' -

6"

6' - 8"

1' -

6"

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:30 PM

19520

A1.20

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

ENLARGED PLANS

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/4" = 1'-0"ENLARGED DOUBLE ROOM 1

SCALE:

1/4" = 1'-0"ENLARGED QUEEN ROOM 2

SCALE:

1/4" = 1'-0"ENLARGED KING ROOM 3

SCALE:

1/2" = 1'-0"ACCESSIBLE BATHROOM 1 4

SCALE:

1/2" = 1'-0"ACCESSIBLE BATHROOM 2 5

KEYNOTES

Key Value Keynote Text

02 PATCH AND REPAIR TO MATCHSURROUNDING WALL; RETAIN FIRE RATINGAS NEEDED

04 NEW WALLS

05 36X48 ACCESSIBLE CLEARANCE ON EITHERSIDE OF BED

06 UPDATE EXISTING THRESHOLD TOACCESSIBLE CODE COMPLIANCE ASNEEDED

Page 18: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

00 EXISTSUBTERRANEAN

88' - 4 1/2"

EXIST 1ST FLOOR99' - 0"

EXIST 2ND FLOOR114' - 0"

EXIST 3RD FLOOR124' - 0"

ROOF134' - 0"

T.O. STAIR144' - 0"

2

A2.01

15' -

0"

10' -

0"

10' -

0"

00 EXISTSUBTERRANEAN

88' - 4 1/2"

EXIST 1ST FLOOR99' - 0"

EXIST 2ND FLOOR114' - 0"

EXIST 3RD FLOOR124' - 0"

ROOF134' - 0"

T.O. STAIR144' - 0"

1

A2.01

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:32 PM

19520

A2.01

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

BUILDING SECTION

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"LONGITUDINAL SECTION 1

SCALE:

1/8" = 1'-0"CROSS SECTION 2

Page 19: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

00 EXISTSUBTERRANEAN

88' - 4 1/2"

EXIST 1ST FLOOR99' - 0"

EXIST 2ND FLOOR114' - 0"

EXIST 3RD FLOOR124' - 0"

ROOF134' - 0"

T.O. STAIR144' - 0"

1

A2.01

10' -

0"

10' -

0"

10' -

0"

15' -

0"

00 EXISTSUBTERRANEAN

88' - 4 1/2"

EXIST 1ST FLOOR99' - 0"

EXIST 2ND FLOOR114' - 0"

EXIST 3RD FLOOR124' - 0"

ROOF134' - 0"

T.O. STAIR144' - 0"

9' -

0"

2

A2.01

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:35 PM

19520

A2.10

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

BUILDING ELEVATIONS

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"WESTWOOD BLVD 1

SCALE:

1/8" = 1'-0"ALLEY ENTRANCE 2

Page 20: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

00 EXISTSUBTERRANEAN

88' - 4 1/2"

EXIST 1ST FLOOR99' - 0"

EXIST 2ND FLOOR114' - 0"

EXIST 3RD FLOOR124' - 0"

ROOF134' - 0"

T.O. STAIR144' - 0"

2

A2.01

00 EXISTSUBTERRANEAN

88' - 4 1/2"

EXIST 1ST FLOOR99' - 0"

EXIST 2ND FLOOR114' - 0"

EXIST 3RD FLOOR124' - 0"

ROOF134' - 0"

T.O. STAIR144' - 0"

1

A2.01

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:38 PM

19520

A2.11

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

BUILDING ELEVATIONS

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/8" = 1'-0"SOUTH ELEVATION 1

SCALE:

1/8" = 1'-0"EAST ELEVATION 2

Page 21: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

UP

UP

UP

7 8 9

A

B

A.2

3' - 9" 8' - 3" 3' - 8"

15' - 8"

8' - 4"

6' -

8"

8' -

0"

5' - 2"

157 SF

LT BIKE

STORAGE

61/2

3/4

5/6

7/8

7 8 9

A

B

A.2

3' - 9" 4' - 7" 7' - 4"

3' - 9" 7' - 4" 4' - 7"

8' -

0"

8' - 4"

4' -

6" 6

' -

8"

15' - 8"

7 8 9

A

B

A.2

3' - 9" 8' - 3" 3' - 8"

5' - 7" 6' - 6" 3' - 7"

8' - 4"

15' - 8"

8' -

0"

6' -

8"

7 8

B

A.2

3' - 9" 8' - 3" 3' - 8" 8' - 4"

5' - 7" 6' - 6" 3' - 7"

15' - 8"

6' -

8"

8' -

0"

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:39 PM

19520

A3.00

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

ENLARGED STAIR 1

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

1/4" = 1'-0"STAIR 1 - SUB 4

SCALE:

1/4" = 1'-0"STAIR 1 - 1ST FLOOR 1

SCALE:

1/4" = 1'-0"STAIR 1 - 2ND FLOOR 2

SCALE:

1/4" = 1'-0"STAIR 1 - 3RD FLOOR 3

Page 22: T:Data01 PROJECTS19520-1936 Westwood Blvd. Hotel1 … · 2020. 5. 7. · accessiblibity requirements 11b-224.2 required guest rooms with mobility features: table 224.2 (26-50 rooms):

PROJECT NUMBER:

SHEET NUMBER:

PROJECT PHASE:

SHEET NAME:

SHEET ISSUE DATE:

ST

A

TE

OF CA L I FOR

NI A

LIC

ENSED ARCH ITECT

NO. C 9412

REN. 5-31-21

_

STEPHEN M.

ALBERT

C:\Users\eyang\Documents\19520-1936 Westwood Blvd.Hotel SD 3_tagarch2032.rvt

2/7/2020 5:40:41 PM

19520

A3.01

WE

ST

WO

OD

HO

TE

L

1936 W

ES

TW

OO

D B

LV

D.

LO

S A

NG

EL

ES

, C

A 9

0025

PRELIMIARY/CONCEPT

DESIGN

SECTION PERSPECTIVES

02/05/2020

Re

vis

ion N

.R

evis

ion D

esc.

Re

vis

ion

Da

te

SCALE:

Long Section Perspective 1

SCALE:

Cross Section Perspective 2