Introduction to CISHChromogenic In Situ Hybridization. Uses chromogen(digoxigenin)-labeled DNA
Probes.
Allows visualization of cellular DNA and can be performed on a tissue section.
Used to quantify the number of gene copies
in cells in a tissue section and demonstrates gene status in tumors.
![Page 3: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/3.jpg)
Available CISH detection kitsGene amplification
Chromosome translocations Deletions Aneuploidy
![Page 4: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/4.jpg)
Can be performed on:FFPE tissues
Blood or bone marrow smears
Metaphase chromosome spreads
Fixed cells
![Page 5: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/5.jpg)
Concordance between IHC, FISH and CISH
Most IHC/CISH studies show concordance between 80 and 100%.
FISH/CISH concordance rates between 90 and 100%.
Generally most IHC/CISH and FISH/CISH studies demonstrate concordance data above 80%.
![Page 6: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/6.jpg)
What is HER2?HER2 (human epidermal growth factor receptor
2) is a protein that plays an important role in cell growth, multiplication, and survival.
Normal cells contain two copies of the HER2 gene and make amounts of HER2 to allow normal cell growth and division.
Some cancer cells, however, contain many more copies of the HER2 gene and in turn produce too much HER2 protein.
This “over expression” of HER2 receptors results in a cancer that is “HER2+.” About 20% to 25% of breast cancer tumors are HER2+ (HER2-positive).
![Page 7: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/7.jpg)
Why HER2 matters
HER2+ cancers grow faster and spread faster than other cancer cells, and they need
to be treated differently..
![Page 8: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/8.jpg)
Methods of HER2 TestingImmunohistochemistry (IHC)
IHC detects the presence of the HER2 protein in tissue samples
Fluorescence in situ hybridization (FISH) Uses fluorescent DNA probes to identify increased copies of the HER2 gene Chromogenic in situ hybridization
(CISH) Allows detection of gene amplification using conventional peroxidase on FFPE tissues
![Page 9: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/9.jpg)
HER2 CISH Kit
Zymed's SPoT-light HER2 CISH Kit is a standardized kit for 20 tests.
HER2 probe purchased separately SPoT-light HER2 probes are stored at -
20oC.
![Page 10: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/10.jpg)
HER2 CISH KitAdditional Materials Required
Super frost/ plus slides
Positive tissue control: FFPE tissue section with HER2 gene amplification
Distilled water Xylene
70%, 85%, 95% and 100% ethanol and 100% methanol.
30% hydrogen peroxide.
Cover slips and rubber cement
![Page 11: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/11.jpg)
HER2 CISH Kit: Equipment Required
Timer Pipettes and
pipette tips Slide rack Slide warmer oven 37 oC incubator
Coplin jars and staining jars
PCR thermal cycler with a slide block
Water bath (capable of reaching 100 oC)
Bright field microscope
![Page 12: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/12.jpg)
CISH step by step
Specimen Preparation
Heat Pretreatment Enzyme digestion Denaturation and
Hybridization
Overnight Incubation
Stringent WashImmunodetectionCounterstaining
![Page 13: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/13.jpg)
Specimen Preparation for CISH1
Fixation and sectioning of tissueTissue should be fixed in 10% neutral buffered
formalin for 12-24 hours prior to paraffin embedding
Tissue sections should be 4-5mm thick and mounted on Super frost/Plus microscope slides
Baking and deparaffinisation Sections should be baked at 60 oC for 15
minutes prior to deparaffinisation or overnight at 37 oC.
![Page 14: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/14.jpg)
Heat Pretreatment2
Coplin jar containing heat pretreatment buffer is heated to 98 oC-100 oC in the water bath
Slides are then placed in the coplin jar and heated at 100 oC for 15 minutes
Slides are then placed in distilled water at Room Temperature
![Page 15: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/15.jpg)
Enzyme digestion3
Tissue is digested with pepsin (provided in Zymed CISH kit)
10 min digestion recommended for most tissues However,
Digestion depends on tissue fixation, type of tissue, decalcification
![Page 16: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/16.jpg)
Denaturation and Hybridization4
Denaturation of probe is performed at 94- 95 oC for 5 minutes in a PCR thermal cycler with slide block
Hybridization must be for at least 12 hours to a maximum of 72 hours at 37 oC
![Page 17: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/17.jpg)
Stringent Wash5
Insufficient wash may lead to high DAB background
Wash must be performed in SSC buffer at 75-80C for 5 min. Do not exceed 80C.
Washes performed at higher temperatures than recommended may result in a complete loss of CISH signal
![Page 18: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/18.jpg)
Immunodetection6
Between immunodetection steps, slides are washed with PBS , pH7.4
Washes are 3 x 2 minutes
Important to keep pH range between pH 7.0-7.5, otherwise may affect staining
Insufficient or lack of washing may lead to high DAB background
![Page 19: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/19.jpg)
Counterstaining7
Requires 1 dip only in Harris haemotoxylin
Strong counterstaining is not recommended as it may mask HER2 signals in nucleus
![Page 20: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/20.jpg)
Evaluation of HER2 Gene Status by CISH
Normal 1-2 copies of the HER2 gene
present per nucleus
![Page 21: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/21.jpg)
Evaluation of HER2 Gene Status by CISH
Low Amplification
6-10 copies of the HER2 gene or a small HER2 gene cluster, present per nucleus in >50% cancer cells.
Amplification
>10 copies, or large clusters of the HER2 gene present in >50% cancer cells
![Page 22: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/22.jpg)
FISH disadvantages advantages CISH
FISHModern expensive
fluorescence microscope with filters
Fluroscence fades quickly (photographic record required )
Morphological features difficult to visualize
CISHBright field
microscope usedPermanent recordHistological analysis
similar to immunohistochemistry
![Page 23: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/23.jpg)
Becoming a CISH Reference Laboratory
Roche invited expression of interest from Labs with experience and/or interest to set-up a CISH service.
Before engaging in a contract with Roche, a certification process was compulsory to be completed by Pathologist(s) and Scientist(s)
![Page 24: Technical Advances](https://reader036.vdocuments.net/reader036/viewer/2022062312/55503425b4c9059f318b501f/html5/thumbnails/24.jpg)