technical catalogue switch disconnectors -...

20
Australian Distributor: Bridex Australia Pty Ltd Telephone: 02.9986.1711 Fax: 02.99861766 T T e e c c h h n n i i c c a a l l C C a a t t a a l l o o g g u u e e Switch Disconnectors Sizes 25 to 200A, 250 to 1000A, 1250 to 3150A Switch Fuses Sizes 32A, 63A, 125A, 200A, 315A, 400A, 630A, 800A

Upload: lynguyet

Post on 26-Jun-2018

312 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

Australian Distributor: Bridex Australia Pty Ltd

Telephone: 02.9986.1711 Fax: 02.99861766

TTeecchhnniiccaall CCaattaalloogguuee

Switch Disconnectors Sizes 25 to 200A, 250 to 1000A, 1250 to 3150A

Switch Fuses Sizes 32A, 63A, 125A, 200A,

315A, 400A, 630A, 800A

Page 2: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

2

Website: www.bridex.com.au Email: [email protected]

Contents

Switch Disconnectors (Sizes 25A, 40A, 63A, 125 & 200A) ...................................3

Switch Disconnectors (Sizes 250A, 400A, 630A, 800A & 1000A).........................4

Switch Disconnectors (Sizes 1250A, 1600A, 1800A, 2500A & 3500A) .................5

Switch Disconnectors Drawing Diagrams 1...........................................................6

Switch Disconnectors Drawing Diagrams 2...........................................................7

Switch Disconnector Accessories .........................................................................8

Switch Fuses Sizes 32A and 63A .......................................................................10

Switch Fuses Sizes 125A and 200A ...................................................................12

Switch Fuses Sizes 315A and 400A ...................................................................14

Switch Fuses Sizes 630A and 800A ...................................................................16

Switch Fuses Drawing Diagrams 1 ...............................................................18

Switch Fuses Drawing Diagrams 2 ...............................................................19

Switch Fuse Accessories.................................................................................20

Page 3: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

3

Switch Disconnectors (Sizes 25A, 40A, 63A, 125 & 200A)

ASTA Certified to IEC 947-3

Tested by TCA Lane Cove, Sydney

Switch Sizes Sizes 25, 40 and 63 Size 125 Size 200 Switch Size 25 40 63 125 200 3-Pole Catalog No. CSSD25D1 CSSD40D1 CSSD63K3 CSSD125D1 CSSD200D1 4-Pole Catalog No. CSSD25D4 CSSD40D4 CSSD63D4 CSSD125D4 CSSD200D4 Rated Insulation Voltage 660V 660V 660V 660V 1000V Rated Operational Voltage 660V 660V 660V 660V 660V Rated Thermal Current (AC21 at 660V AC)

Open 40°C Ambient 25A 40A 63A 125A 250A Encl 40°C Ambient 25A 40A 63A 125A 200A Encl 60°C Ambient 25A 32A 50A 100A 175A (D21 at 220V Open 40°C Ambient 25A 40A 63A - 200A Rated Operational Current AC22/AC23 at 415V 25/25A 40/25A 63/63A 125/75A 250/200A AC22/AC23 at 660V 25/16A 40/25A 63/30A 80/35A 250/200A DC22/DC23 at 220V 25/-A 40/-A 40/-A 50/50A 200/200A Rated Operational Power AC23 at 415V 7.5kW 11kW 25kW 37kW 100kW Fused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating 40A 50A 80A 125A 200A Maximum Peak Let Through (protected with back up fuses) 4.5kA 5kA 8kA 10kA 40kA

Short Circuit Making (peak) 1.53kA 1.7kA 2.55kA 4.25kA 40kA Short Time Withstand 0.1 second 1.3kA 1.4kA 1.9kA 2.5kA 30kA 1.0 second 0.9kA 1.0kA 1.5kA 2.5kA 24kA AC Breaking Capacity p.f. 0.35/415V 250A 320A 500A 600A 1600A DC Breaking Capacity 220V (3p in series L/R=15mS) 160A* 160A* 160A* 200A* 1260A**,***

Capacitor Rating 415V - - - 50KVAr 90KVAr Rated Capacitor Duty Ic - - - 80A 135A Mechanical/Electrical Endurance (at rated operational Current p.f.0.65)

40k/5k operations

40k/5k operations

40k/5k operations

40k/5k operations

10k/1k operations

Weight 3-Pole 0.2kg 0.2kg 0.3kg 0.3kg 4.5kg 4-Pole 0.25kg 0.25kg 0.4kg 0.4kg 5.4kg Notes: * L/R = 2.5mS ** With one pole when tested at 48/110V DC *** Two poles in series.

Page 4: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

4

Switch Disconnectors (Sizes 250A, 400A, 630A, 800A & 1000A) ASTA Certified to IEC 947-3

Tested by TCA Lane Cove, Sydney

Switch Sizes Sizes 250 and 400 Size 630 and 800 Size 1000 Switch Size 250 400 630 800 1000 3-Pole Catalog No. CSSD250D1 CSSD400D1 CSSD630K3 CSSD800K3 CSSD1000K3 4-Pole Catalog No. CSSD250D4 CSSD400D4 CSSD630K4 CSSD800K4 CSSD1000K4 Rated Insulation Voltage 1000V 1000V 1000V 1000V 1000V Rated Operational Voltage 660V 660V 660V 660V 660V

Rated Thermal Current (AC21 at 660V AC)

Open 40°C Ambient 315A 500A 630A 800A 1000A Encl 40°C Ambient 250A 400A 630A 720A 1000A Encl 60°C Ambient 220A 350A 500A 600A 900A (D21 at 220V Open 40°C Ambient 250A 400A 630A 800A 1000A Rated Operational Current AC22/AC23 at 415V 315/250A 500/400A 630/630A 800/700A 1000/800A AC22/AC23 at 660V 315/250A 500/400A 630/420A 800/420A - DC22/DC23 at 220V 250/250A 400/400A 400/630A** 500/630A** - Rated Operational Power AC23 at 415V 130kW 200kW 315kW 350kW 400kW Fused Short Circuit Current 100kA 100kA 80kA 80kA 50kA With Back Up Fuse Rating 250A 400A 630A 800A 800A Maximum Peak Let Through (protected with back up fuses) 40kA 40kA - - -

Short Circuit Making (peak) 40kA 40kA 50kA**** 50kA**** 105kA Short Time Withstand 0.1 second 30kA 35kA 35kA 40kA 60kA 1.0 second 24kA 24kA 24kA 24kA 50kA AC Breaking Capacity p.f. 0.35/415V 2000A 3200A 5040A 5760A 6400A DC Breaking Capacity 220V (3p in series L/R=15mS) 1260A** 1600A** 1600A** 2000A** 1900A**

Capacitor Rating 415V 110KVAr 250KVAr 300KVAr 350KVAr 630KVAr Rated Capacitor Duty Ic 170A 400A 450A 500A 900A

Mechanical/Electrical Endurance (at rated operational Current p.f.0.65)

10k/1k operations

10/1k operations

10k/0.5k operations

10k/0.5k operations

10k/0.5k operations

Weight 3-Pole 4.5kg 4.5kg 5.2kg 5.4kg 11.5kg 4-Pole 5.4kg 5.4kg 6.1kg 6.5kg 15kg Notes: ** Two Poles in Series **** Distance between terminal bolts and insulator of the busbar, 2 x pole distance.

Page 5: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

5

Switch Disconnectors (Sizes 1250A, 1600A, 1800A, 2500A & 3500A) ASTA Certified to IEC 947-3

Tested by TCA Lane Cove, Sydney

Switch Sizes Size 1250 Sizes 1600 and 1800 Sizes 2500 and 3150 Switch Size 1250 1600 1800 2500 3150 3-Pole Catalog No. CSSD1250K3 CSSD1600K3 CSSD1800K3 CSSD2500K3 CSSD3150K34-Pole Catalog No. CSSD1250K4 CSSD1600K4 CSSD1800K4 CSSD2500K4 CSSD3150K4 Rated Insulation Voltage 1000V 1000V 1000V 1000V 1000V Rated Operational Voltage 660V 660V 660V 660V 660V

Rated Thermal Current (AC21 at 660V AC)

Open 40°C Ambient 1250A 1600A 1800A 2500A 3150A Encl 40°C Ambient 1250A 1600A 1600A 2300A 2700A Encl 60°C Ambient 1000A 1250A 1250A - - (D21 at 220V Open 40°C Ambient 1250A 1600A 1600A 1600A 1600A Rated Operational Current AC22/AC23 at 415V 1250/800A 1600/800A 1600/800A 1600/-A 1000/-A AC22/AC23 at 660V - DC22/DC23 at 220V - Rated Operational Power AC23 at 415V 400kW 400kW 400kW 400kW 400kW Fused Short Circuit Current 50kA 50kA* 50kA* 50kA* 50kA* With Back Up Fuse Rating 1000A 1250A 1250A 1250A 1250A

Maximum Peak Let Through (protected with back up fuses) - - - - -

Short Circuit Making (peak) 105kA 105kA 105kA 105kA 105kA Short Time Withstand 0.1 second 60kA 60kA 60kA 110kA 110kA 1.0 second 50kA 50kA 50kA 80kA 80kA AC Breaking Capacity p.f. 0.35/415V 6400A 6400A 6400A 6400A 6400A

DC Breaking Capacity 220V (3p in series L/R=15mS) 1900A** 2600A** 2600A** 2600A** 2600A**

Capacitor Rating 415V - - - - - Rated Capacitor Duty Ic - - - - - Mechanical/Electrical Endurance (at rated operational Current p.f.0.65)

10k/0.5k operations

10k/0.5k operations

10k/0.5k operations

6k/0.5k operations

6k/0.5k operations

Weight 3-Pole 11.5kg 15.6kg 15.6kg 36.2kg 36.2kg 4-Pole 15.0kg 20.0kg 20.0kg 45.4kg 45.4kg Notes: * With back up circuit breaker time delayed 0.5 second maximum ** Two poles in series

Page 6: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

6

Switch Disconnectors Drawing Diagrams 1 Switch Disconnectors: Dimensions (mm)

CSSD25,40 D1/D4 CSSD25, 40 D1/C1 CSSD25, 40 D4/C4 CSSD25, 40 C1/C4

CSSD63K3 CSSD63K3/C3 CSSD63C3

Handle CSSDZX104

Handle CSSDZX104

CSSD125D1 CSSD63D3, 125D4 CSSD125D1/C1 CSSD63D4, 125D4/C4 CSSD125C1/C4

Handle CSSDZX104

Page 7: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

7

Switch Disconnectors Drawing Diagrams 2 Switch Disconnectors Dimensions (mm)

TYPE a b c d CSSD1000K3 343 278 80 12 CSSD1000K4 423 358 80 12 CSSD1250K3 343 278 80 12 CSSD1250K4 423 358 80 12 CSSD1600K3 461 396 139 16 CSSD1600K4 600 535 139 16 CSSD1800K3 461 396 139 16 CSSD1800K4 600 535 139 16 Handle: YASDB16 Shaft : CSSFZK9

L = 255mm

TYPE a b c d e f g h CSSD200D1 211 151 46 25 12.5 180 15.0 11.0 CSSD200D4 257 197 46 25 12.5 180 15.0 11.0 CSSD250D1 211 151 46 25 12.5 180 15.0 11.0 CSSD250D4 257 197 46 25 12.5 180 15.0 11.0 CSSD400D1 211 151 46 25 12.5 180 15.0 11.0 CSSD400D4 257 197 46 25 12.5 180 15.0 11.0 CSSD630K3 244 183 62 40 19.0 185 17.5 13.5 CSSD630K4 306 245 62 40 19.0 185 17.5 13.5 CSSD800K3 260 199 70 40 19.0 185 17.5 13.5 CSSD800K4 330 269 70 40 19.0 185 17.5 13.5 Handle: YASDB16 Shaft : CSSFZK9

L = 255mm

TYPE a b CSSD2500K3 468 403 CSSD2500K4 607 542 CSSD3150K3 468 403 CSSD3150K4 607 542 Handle: YASDA8 Shaft : CSSFZK41

L = 325mm

Page 8: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

8

Switch Disconnector Accessories

EXTENDED SHAFTS

Shaft Dimension Switch Size Length (mm) Catalog No.

5 mm square CSSD25 ....... 125 150 CSSDZS37

12 mm square CSSD200 ..... 1600 250 CSSDFZK41

12 mm square CSSD200 ..... 3150 465 CSSDFZK44

AUXILLIARY CONTACTS

Switch Size No. Poles Catalog No.

CSSD25 D1 3-pole CSSDZX49 CSSD40 D1 3-pole CSSDZX49 CSSD63 D4 4-pole CSSDZX87 CSSD63 K3 3-pole CSSDZX79 CSSD125 D1 3-pole CSSDZX52

CSSD25 D1 3-pole CSSDZX50 CSSD40 D1 3-pole CSSDZX50 CSSD63 D4 4-pole CSSDZX88

CSSD63 K3 3-pole CSSDZX80

CSSD125 D1 3-pole CSSDZX53

CSSD200 to CSSD400 3-pole CSSDZX34

CSSD630 to CSSD3150 3-pole CSSDZX35

CSSD630 to CSSD3150 3-pole CSSDZX36

Terminal Shrouds CSSD125 D1 3-pole CSSDZX9 CSSD200 D1 3-pole CSSDZX11

CSSD250 D1 3-pole CSSDZX31 CSSD400 D1 3-pole CSSDZX31 CSSD630 K3 3-pole CSSDZX93 CSSD800 K3 3-pole CSSDZX112

CSSD1000 K3 3-pole CSSDZX102 CSSD1250 K3 3-pole CSSDZX102 CSSD125 D4 4-pole CSSDZX59

CSSD200 D4 4-pole CSSDZX64 CSSD250 D4 4-pole CSSDZX32 CSSD400 D4 4-pole CSSDZX32 CSSD630 K4 4-pole CSSDZX94 CSSD800 K4 4-pole CSSDZX112

CSSD1000 K4 4-pole CSSDZX102

CSSD1250 K4 4-pole CSSDZX102

Page 9: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

9

Changeover Mechanisms CSSD25 to CSSD125 CSSDZW6

CSSD200 to CSSD800 CSSDZW11

CSSD1000 to CSSD3150 CSSDZW12

Locking Attachment

CSSD25 to CSSD125 CSSDZW16

CSSD200 to CSSD3150 CSSDZW5

Handles

ON – OFF CSSD25 to CSSD125 CSSDZX104 ON – OFF CSSD200 to CSSD800 YASDB16 ON – OFF CSSD1000 to CSSD3150 YASDA8 ON - OFF - ON CSSD25 to CSSD125 YASDB37

ON - OFF - ON CSSD200 to CSSD3150 YASDA6

Page 10: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

10

Switch Fuses Sizes 32A and 63A Catalogue Nos: CSSF32GI and CSSF63GI

ASTA Certified to IEC 947-3

Tested by TCA Lane Cove, Sydney

Switch Sizes Sizes 32 and 63 BS Pattern Catalog No. CSSF32GI CSSF63GI Rated Insulation Voltage 750V 750V Rated thermal current & operational In free air 660V 32A 63A current AC22 Ambient temp. 40°C In enclosure (no ventilation) 660V 32A 63A free mounting position. note (1) In enclosure (solid links) 660V 40A 75A

Rated Operational voltage 500V 660V Rated operational current in categories 220V 32A 63A AC23 and AC3. Time interval between 380V 32A 63A operations 20 seconds in AC3. 415V 32A 63A 660V - 40A Rated operational current DC23 Two poles in series 110V - 63A Two poles in series 220V - 63A Three poles in series 440V - 30A

Rated operational power in categories 220V 7.5kW 15kW AC23 and AC3. Time interval 380V 11kW 30kW between operations 415V 15kW 30kW 20 seconds in AC3 note (2) 500V 15kW 30kW 660V - 30kW

Rated breaking capacity 500V 300A 500A AC23.COSø = 0.35 660V - 350A Rated breaking capacity 110V - 300A DC, L/R = 15mS 220V - 250A 440V - - Rated fused short circuit current R.M.S. Value 500V 50kA 50kA and making capacity on Peak Value 500V 105kA 105kA fault level ......... R.M.S. Value 660V 50kA 50kA Peak Value 660V 105kA 105kA ........with back up fuses of rating 35A 63A Maximum peak let through current 660V 6kA 10KA (4) Rated short-time withstand current 1sec 660V 15kA 2kA Rated capacitor power note (3) 380V 15kVAr 30kVAr 415V 16kVAr 32kVAr

Page 11: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

11

Mechanical / Electrical endurance 3-pole switch fuses 20000/1500 20000/1500 at rated current PF 0.65 operations operations Fuse types BS pattern BS88 A2-A3 A2-A3 distance of fixing holes 73mm 73mm Weight 3-pole switch fuses 1.6kg 1.6kg Notes: (1) Ambient temperature 60°C, derating 20% mounting on 'ceiling', derating 10% on 'wall', horizontal 8%. (2) Some fuse links limit these figures further. Starting current characteristics must be considered separately. (3) The capacitor rating of the switch fuse is limited by the fuse link. (4) UC-415V at 660V max peak let through is 8kA.

Page 12: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

12

Switch Fuses Sizes 125A and 200A Catalogue Nos: CSSF100GI and CSSF200B3

ASTA Certified to IEC 947-3

Tested by TCA Lane Cove, Sydney

Switch Sizes

Size 125

Size 200

BS Pattern Catalog No. CSSF100GI CSSF200B3 Rated Insulation Voltage 750V 750V Rated thermal current & operational In free air 660V 125A 200A current AC22 Ambient temp. 40°C In enclosure (no ventilation) 660V 115A 200A free mounting position. note (1) In enclosure (solid links) 660V 125A 280A

Rated Operational voltage 660V 660V Rated operational current in categories 220V 115A 200A AC23 and AC3. Time interval between 380V 115A 200A operations 20 seconds in AC3. 415V 115A 200A 660V 115A 200A Rated operational current DC23 Two poles in series 110V 63A 200A Two poles in series 220V 125A 200A Three poles in series 440V 100A 200A

Rated operational power in categories 220V 37kW 57kW AC23 and AC3. Time interval 380V 55kW 100kW between operations 415V 60kW 110kW 20 seconds in AC3 note (2) 500V 75kW 140kW 660V 55kW 180kW

Rated breaking capacity 500V 800A 3200A AC23.COSø = 0.35 660V 500A 3200A Rated breaking capacity 110V 500A 1600A DC, L/R = 15mS 220V 400A 1200A 440V - 1200A Rated fused short circuit current R.M.S. Value 500V 80kA 100kA and making capacity on Peak Value 500V 175kA 220kA fault level ......... R.M.S. Value 660V 50kA 100kA Peak Value 660V 105kA 220kA ........with back up fuses of rating 125A 200A Maximum peak let through current 660V 18kA 40KA Rated short-time withstand current 1sec 660V 5kA 8kA Rated capacitor power note (3) 380V 50kVAr 90kVAr 415V 55kVAr 100kVAr

Page 13: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

13

Mechanical / Electrical endurance 3-pole switch fuses 15000/1000 10000/1000 at rated current PF 0.65 operations operations Fuse types BS pattern BS88 A2-A4 B1-B2 distance of fixing holes 94mm 111mm Weight 3-pole switch fuses 2.1kg 6.9kg Notes: (1) Ambient temperature 60°C, derating 20% mounting on 'ceiling', derating 10% on 'wall', horizontal 8%. (2) Some fuse links limit these figures further. Starting current characteristics must be considered separately. (3) The capacitor rating of the switch fuse is limited by the fuse link.

Page 14: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

14

Switch Fuses Sizes 315A and 400A

Catalogue Nos: CSSF315B3 and CSSF400B3

ASTA Certified to IEC 947-3

Tested by TCA Lane Cove, Sydney

Switch Sizes Sizes 315 and 400 BS Pattern Catalog No. CSSF315B3 CSSF400B3 Rated Insulation Voltage 750V 750V Rated thermal current & operational In free air 660V 315A 400A current AC22 Ambient temp. 40°C In enclosure (no ventilation) 660V 290A 345A free mounting position. note (1) In enclosure (solid links) 660V 400A 450A

Rated Operational voltage 660V 660V Rated operational current in categories 220V 315A 400A AC23 and AC3. Time interval between 380V 315A 400A operations 20 seconds in AC3. 415V 315A 400A 660V 315A 400A Rated operational current DC23 Two poles in series 110V 315A 400A Two poles in series 220V 315A 400A Three poles in series 440V 300A 400A

Rated operational power in categories 220V 90kW 110kW AC23 and AC3. Time interval 380V 160kW 210kW between operations 415V 180kW 230kW 20 seconds in AC3 note (2) 500V 220kW 280kW 660V 290kW 330kW

Rated breaking capacity 500V 3200A 3200A AC23.COSø = 0.35 660V 3200A 3200A Rated breaking capacity 110V 1600A 1600A DC, L/R = 15mS 220V 1600A 1600A 440V 1600A 1600A Rated fused short circuit current R.M.S. value 500V 100kA 100kA and making capacity on Peak value 500V 220kA 220kA fault level ......... R.M.S. value 660V 100kA 50kA Peak value 660V 220kA 105kA ........with back up fuses of rating 315A 400A Maximum peak let through current 660V 45kA 45KA Rated short-time withstand current 1sec 660V 10kA 10kA Rated capacitor power note (3) 380V 145kVAr 180kVAr 415V 160kVAr 200kVAr

Page 15: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

15

Mechanical / Electrical endurance 3-pole switch fuses 10000/1000 10000/1000 at rated current PF 0.65 operations operations Fuse types BS pattern BS88 B1-B3 B1-B4 distance of fixing holes 111mm 111mm Weight 3-pole switch fuses 7.3kg 7.8kg Notes: (1) Ambient temperature 60°C, derating 20% mounting on 'ceiling', derating 10% on 'wall', horizontal 8%. (2) Some fuse links limit these figures further. Starting current characteristics must be considered separately. (3) The capacitor rating of the switch fuse is limited by the fuse link.

Page 16: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

16

Switch Fuses Sizes 630A and 800A Catalogue Nos: CSSF630B3 and CSSF800B3

ASTA Certified to IEC 947-3

Tested by TCA Lane Cove, Sydney

Switch Sizes Sizes 630 and 800 BS Pattern Catalog No. CSSF630B3 CSSF800B3 Rated Insulation Voltage 750V 750V Rated thermal current & operational In free air 660V 630A 800A current AC22 Ambient temp. 40°C In enclosure (no ventilation) 660V 560A 720A free mounting position. note (1) In enclosure (solid links) 660V 700A 900A Rated Operational voltage 660V 660V Rated operational current in categories 220V 630A 800A AC23 and AC3. Time interval between 380V 630A 800A operations 20 seconds in AC3. 415V 630A 800A 660V 630 720A Rated operational current DC23 Two poles in series 110V 630A 720A Two poles in series 220V 630A 800A Three poles in series 440V 630A 800A Rated operational power in categories 220V 180kW 200kW AC23 and AC3. Time interval 380V 315kW 350kW between operations 415V 340kW 380kW 20 seconds in AC3 note (2) 500V 400kW 470kW 660V 540kW 600kW Rated breaking capacity 500V 5040A 6400A AC23.COSø = 0.35 660V 5040 6400A Rated breaking capacity 110V 3200A 3200A DC, L/R = 15mS 220V 2500A 2500A 440V 2500A 2500A Rated fused short circuit current R.M.S.value 500V 80kA 80kA and making capacity on Peakvalue 500V 175kA 175kA fault level ......... R.M.S.value 660V 50kA 50kA Peakvalue 660V 105kA 105kA ........with back up fuses of rating 630A 800A Maximum peak let through current 660V 50kA 65kA Rated short-time withstand current 1sec 660V 16kA 16kA Rated capacitor power note (3) 380V 250kVAr 310kVAr 415V 270kVAr 340kVAr

Page 17: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

17

Mechanical / Electrical endurance 3-pole switch fuses 6000/1000 6000/500 at rated current PF 0.65 operations operations Fuse types BS pattern BS88 C1-C2 C1-C3 distance of fixing holes 133, 184mm 133, 184mm Weight 3-pole switch fuses 15.5kg 17.0kg

Notes: (1) Ambient temperature 60°C, derating 20% mounting on 'ceiling', derating 10% on 'wall', horizontal 8%. (2) Some fuse links limit these figures further. Starting current characteristics must be considered separately. (3) The capacitor rating of the switch fuse is limited by the fuse link.

Page 18: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

18

Switch Fuses Drawing Diagrams 1 Switch Fuses: Dimensions (mm)

CSSF32G1 CSSF63G1 Handle: YASDB20 Shaft: CSSFZS13 L = 185mm

CSSF100G1 Handle: YASDB20 Shaft: CSSFZS13 L = 165mm

CSSF200B3 Handle: YASDB16 Shaft: CSSFZS41 L = 255mm

Page 19: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

19

Switch Fuses Drawing Diagrams 2 Switch Fuses: Dimensions (mm)

CSSF315B3 CSSF400B3 Handle: YASDB16 Shaft: CSSFZK41 L = 255mm

CSSF630B3 CSSF800B3 Handle: YASDA8/YASDB16 Shaft: CSSFZK41 L = 255mm

Page 20: Technical Catalogue Switch Disconnectors - BRIDEXbridex.com.au/download/control/C_S_Technical_Catalogue.pdfFused Short Circuit Current 50kA 50kA 50kA 50kA 100kA With Back Up Fuse Rating

20

Switch Fuse Accessories

Extended Shafts Shaft Dimension Switch Size Length (mm) Catalog No.

6mm square 32A to 125A 150mm CSSFZS13

430mm CSSFZS31

12mm square 200A to 800A 250mm CSSFZK41 465mm CSSFZK44

Auxiliary Contacts 32A to 63A CSSFZX46 125A CSSFZX1

200 to 800A CSSFZX34

32A to 63A CSSFZX32

125A CSSFZX16

200 to 800A CSSFZX36 Terminal shrouds Poles Switch Type No. required Catalog No.

3-poles CSSF100GI 2 CSSZX8

3-poles CSSF200B3 2 CSSFZX70

CSSF250B3

3-poles CSSF315B3 2 CSSFZX72 CSSF400B3

3-poles CSSF630B3 6 CSSFZX104 CSSF800B3

Changeover Mechanisms Switch Type Catalog No. 32A to 125A CSSFZW1

200A to 400A CSSFZW12/1

630A to 800A CSSFZW12

Locking Attachment ETSF200 to 800A CSSDZW5