Customer Ref.: Email dated 25/02/2015Oracle: TC-141639-01-00 DOCUMENT TITLE Page 1 of 1
TECHNICAL CLARIFICATION Date: 03/03/2015
Technical Engineer: Technical Manager:
Serial No
CUSTOMER REQUIREMENTS MESC CLARIFICATIONFINAL
DECISION BYPURCHASER
1
GASCO Doc. No. DOD-600512-PL-800-15-00-002 Rev. 0 Item no. 4.5 in the BOQ refers color identification of Brown & Blue for 2-core and also refers to Cl. 9.2.43 of DGS-1511-036 Rev. 1.
As per Cl. 9.2.43 of DGS-1511-036 Rev. 1, color identification for 2-core is Red & Black and same has been provided by MESC. Customer to confirm the requirement.
2DGS-1511-036 Rev. 1 Cl. 9.2.1 & GASCO Doc. No. DOD-600512-PL-800-15-00-002 Rev. 0 Item no. 4.1~4.4 refers BS 5308.
BS 5308 is obsolete and replaced by BS EN 50288-7. None of the international laboratory provide type test certificate with BS 5308 standard. Hence MESC offer as per BS EN 50288-7. All electrical, dimensional and technical parameters are as per BS EN 50288-7 500V grade.
3GASCO Doc. No. DOD-600512-PL-800-15-00-002 Rev. 0 Item no. 4.6~4.9 refer color identification of Brown & Blue for 5-core & above.
MESC has provided color identification as per Cl. 9.2.48 of DGS-1511-036 Rev. 1, White core with Black number printing and the last core being Green/Yellow for 5-core & above.
4DGS-1630-029 Rev. 1 Cl. 10.2.2 refers inner sheath of lead sheath to EEMUA 133.
MESC has provided lead sheath as per IEC 60502-1 which supersedes EEMUA 133.