technical data px200n - ebs sp. z o.o. · sms sm s / csd internet tcp/ip udp tcp/ip, rs 232 surgard...

2
PX200N Technical Data PX200N parameters Transmission channels GPRS, SMS, PSTN Inputs 8 (NO/NC) + 1 SAB (NO/NC) Phone input compatible with DTMF standard YES Outputs 1 (OC, max. load 100mA) 1 relay output (NO/NC, max. load 1A) Output functions (ways of control) - unavailable GSM signal - from server or through SMS - incoming CLIP - in reaction on inputs Power output +12V YES (max. load 200mA) Serial interface RS232 / RS485 (lines: RxD, TxD, RTS, CTS) transmission speed up to 115200bps Quantity of system events stored in history 5000 GPRS/SMS transmission security AES encryption Status LEDs (functions) 4 LEDs (GSM signal level, device state, DTMF communication) Configuration Remote: GPRS, SMS, CSD Local: PC through RS232 (required cable: LX-PROG) Remote firmware update YES Supported modems - Cinterion MC55, MC55i, MC56 (previously Siemens) - Wavecom Q55 - Simcom SIM300C, SIM340C Power supply parameters - PCB (without casing) Voltage supply 18VAC (acceptable: 16-20V AC ) Power consumption (average / max) 80mA/300mA@18V AC Power supply parameters - PCB in metal casing Voltage supply 230V AC (acceptable: 190-250V AC ) Power consumption (average / max) 3W/20W@230V AC Charging module functions (in version PCB in metal casing) - protection against reverse battery connection - AC failure signalization - low battery/no battery signalization - protection against short circuit battery output - polymer fuse Backup battery connection YES, lead-acid 12V Battery charging current max. 220mA Threshold of signaling low AC voltage (at secondary / at primary) 13.5V AC / 160V AC (with EBS transformer) Threshold of signaling low battery voltage 11V DC Dimensions PCB: 146 x 73 x 35mm PCB in metal casing: 255 x 255 x 90mm REAL TIME GPRS TRANSMITTER www.ebs.pl [email protected] +48 22 812 05 05

Upload: vukiet

Post on 20-May-2018

252 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Technical Data PX200N - EBS Sp. z o.o. · sms sm s / csd internet tcp/ip udp tcp/ip, rs 232 surgard protocol surgard protocol gprs/sms/csd pstn public ip opened port sms module …

PX200NTechnical Data

PX200N parameters

Transmission channels GPRS, SMS, PSTN

Inputs 8 (NO/NC) + 1 SAB (NO/NC)

Phone input compatible with DTMF standard YES

Outputs1 (OC, max. load 100mA)

1 relay output (NO/NC, max. load 1A)

Output functions (ways of control)

- unavailable GSM signal - from server or through SMS - incoming CLIP - in reaction on inputs

Power output +12V YES (max. load 200mA)

Serial interface RS232 / RS485 (lines: RxD, TxD, RTS, CTS) transmission speed up to 115200bps

Quantity of system events stored in history 5000

GPRS/SMS transmission security AES encryption

Status LEDs (functions) 4 LEDs (GSM signal level, device state, DTMF communication)

ConfigurationRemote: GPRS, SMS, CSD

Local: PC through RS232 (required cable: LX-PROG)

Remote firmware update YES

Supported modems

- Cinterion MC55, MC55i, MC56 (previously Siemens)

- Wavecom Q55

- Simcom SIM300C, SIM340C

Power supply parameters - PCB (without casing)

Voltage supply 18VAC (acceptable: 16-20VAC )

Power consumption (average / max) 80mA/300mA@18VAC

Power supply parameters - PCB in metal casing

Voltage supply 230VAC (acceptable: 190-250VAC )

Power consumption (average / max) 3W/20W@230VAC

Charging module functions(in version PCB in metal casing)

- protection against reverse battery connection - AC failure signalization - low battery/no battery signalization - protection against short circuit battery output - polymer fuse

Backup battery connection YES, lead-acid 12V

Battery charging current max. 220mA

Threshold of signaling low AC voltage (at secondary / at primary) 13.5VAC / 160VAC (with EBS transformer)

Threshold of signaling low battery voltage 11VDC

DimensionsPCB: 146 x 73 x 35mm

PCB in metal casing: 255 x 255 x 90mm

real Time gprs TransmiTTer

www.ebs.plo f f i c e @ e b s . p l+48 22 812 05 05

Page 2: Technical Data PX200N - EBS Sp. z o.o. · sms sm s / csd internet tcp/ip udp tcp/ip, rs 232 surgard protocol surgard protocol gprs/sms/csd pstn public ip opened port sms module …

PX200N transmitters are modern devices used for the real time packet data transfer through GSM networks via GPRS and SMS channels. Moreover devices are equipped with DTMF input ena-bling telephone line simulation and communication with control panel’s dialer.

PX200N transmitters are used mainly as the transfer module from security systems. Devices co-operate with all of the most popular alarm systems. Usage of the packet data transfer (GPRS) allows to reduce the alarm system functioning costs.

The possibility of PX200N application is much broader. They can be applied everywhere where there exists a necessity to collect information and send them over distance in real time. Thanks to the intuitive and flexible configuration they may be applied in systems with specific requirements ex. energy consumption measurement systems, vending machines control systems, meteorological station, elevator systems and many others.

PX200N transmitters are offered independently or in sets with metal casing, AC ada-pter and accumulator. Support for devices in monitoring station is carried out by Monito-ring System Receiver OSM.2007. It is offered in the form of independent receiver ensuring complete transfer reliability thanks to redundancy, which protects receiving system if part of the system is damaged, or as a server software for Windows.

» remote configuration and firmware upgrade comfortable servicing and time savings

» modem sleep mode elimination of unsuccessful transfer in the absence of AC power and low battery voltage, extension of battery cycle life

» encryption of transmitted data by aes standard full data transfer safety

» Complex telephone line simulation circuit and DTmF receiving (ContactiD, ademco express) flexible co-operation with alarm control panels equipped with dialer and telephone exchanges of various manufacturers

» sending of text messages of any desired content to the 5 defined cellphone numbers immediate signification of the alarm situations occurrence

» system event history evidence up to 5000 events enabling to diagnose of possible problems

» Device status monitor diagnostic mode for the installer

» authorization for configuration and steering text messages protection against unauthorized device access

» reduced power consumption extension of device operating time on backup power supply

» automatic lock of inputs protection against generating needless costs

» possibility of setting priority for psTn or gprs channel adapting the device to the individual needs

» gsm/gprs connection control automatic retrieving of the connection with the monitoring station

» sent text messages quantity control, incoming messages retransmission supervision over transmission costs

» embedded rs232/rs485 serial interface co-operation with industrial devices

» steering via Clip costless output connection

» reserve server servicing transmission protection in case of a server damage

» modem choice between three leading manufacturers adapting the device to the individual preferences

PX200N

INP

UTS

OU

TPU

TS

SM

S

SM

S/C

SD

INTE

RN

ET

TCP

/IP U

DP

TCP/IP, RS 232 SurGard Protocol

SurGard Protocol

GPRS/SMS/CSD

PSTN

PUBLIC IPOPENED PORTSMS MODULE

OSM.2007MONITORINGSYSTEM RECEIVERGSM/GPRS/INTERNET

CELLPHONES

RS

232

/ R

S 4

85

XML Protocol

DTM

F: C

onta

ctID

, Ade

mco

Exp

ress GSM

PROVIDERSTATIONMONITORING

RECEIVER MLR2

MONITOREDOBJECTS