1Features
2WorkingScheme
6TracksAnchorageSystems
3Sections
4Elements
5TracksandCoverings
7StackingSchemes
8TrolleysandTracks
9IdeasforPlanning
MAXPARETEHSPHighSoundProofingMATIC
Features
MAXPARETE HSP MATIC - Features - 1
MAXPARETE HSP MATIC operable partition represents the ideal solution in order to dynamically close rooms high up to more than 10 meters, assuring a perfect sound proofing.
MAXPARETE HSP MATIC consists of independent elements (ready for home automation) covered with high density chipboard panels 16/18 mm thick that can be finished with a wide variety of finishings. The elements slide by ball bearing trolleys in a track fixed only to the ceiling. This system eliminates floor guides or floor attachments which are antiaesthetic and encumber the way.
As the elements are manually set in their position by operators, a series of motorized mechanisms housed in the elements start to operate the rubber seals and lock the element. The last element of the wall has one more moving telescopic mechanism, with a side sliding. The mobile head closes the gap horizontally, locking both mechanically and acoustically and self-adapting if surrounding concrete walls are not perfectly vertical.
A starting jamb with a touch-button commander is always necessary.
Pass doors of different measures may be fitted to any intermediate panel (except for the telescopic closure panel) of the MAXPARETE HSP MATIC manoeuvrable walls without altering the normal functionality.
Technical Characteristics
Standard elements are 106 / 110 mm thick for sound insulation up to 50 dB. Thickness is 126 mm for higher insulation.
FinishingsMAXPARETE HSP MATIC is available in a wide choice of finishings:
Aluminium natural profiles
Panels surfaces in:- Raw standard chipboard or raw fire-resistant chipboard to be covered by customer with upholstery, cloth, carpet, etc.- Raw melamine paper on fire-resistant chipboard- Standard colours melamine paper on fire-resistant chipboard- Standard colours High Pressure Laminate on normal or fire-resistant chipboard- Standard vinyl coverings on normal or fire-resistant chipboard- Wood coverings (Mahogany, Tanganika, Douglas, Elm, Mansonia, Ash, Pine, Oak, Teak, Chestnut and others on request) on normal or fire-resistant chipboard
Sound ProofingWhen closed the operable partition is perfectly aligned, without fissures and mechanical parts in view. MAXPARETE HSP MATIC allows a sound proofing (Rw index) from 41 to 57 dB according to the types.
The materials used for the supply are tested according to UNI EN ISO 717-1 and UNI EN ISO 10140-2 standards. The test report (if demanded) is available within 30 days maximum prior to the delivery of the partitions, evidencing the conformity to the soundproofing requests and is attached to the transport documents.
MAXPARETE HSP MATIC - Features - 2
More, the customer can assist to the tests with at least a 15 days warning.
Fire Reaction- High Pressure Laminate on fire-resistant chipboard: Class 1 (UNI 9174) - Class B,s1-d0 (EN 13501-1)- Melamine paper on fire-resistant chipboard: Class 1 (UNI 9174) - Class B,s2-d0 (EN 13501-1)- Wood coverings with fireproof paint on fire-resistant chipboard: Class 1 (UNI 9174)- Raw melamine paper on fire-resistant chipboard: Class B,s2-d0 (EN 13501-1)
Resistance to ShocksUNE 41956-1 compliant
Electronic controlThe control is operated by independent and “intelligent” units set into each element, feeded by a 24 or 48 Vdc line (electric contacts are in view and accessible; it is necessary to feed in low-tension to match the 2006/42/CE European Committee Directive). Elements communicate by a one-wire BUS and have no needs of calibration or particular operations during installation. You can change the position, add or remove one or more elements (i.e., multiple dispositions) without any need of new programming (elements automatically self-update). Telescopic element has ALWAYS safety bars that interrupt working in case of danger / obstacles. In case of secondary partition trees (partitions originating from a main one), the element of the main partition with the “T” jamb will show a secondary control (the same kind of key-selector) that will control the secondary tree.
The system allows linking with building systems (lights, air conditioning, etc.) by an external controlled module: particularly if the building systems are yet to be done or to be modified, they can be planned to be also controlled by systems embedded into Maxparete wall (i.e. light switches, thermostats, etc.) In case of lack of electrical feeding, all elements have a manual unlock system, moved by a small removable hexagonal key, given apart.
InstallationInstallation is quick and easy; the customer is only required to supply a standard 220 Vac power point near the power supply unit. The power supply unit (usually placed above the starting jamb) has to be kept available for inspection and extraordinary maintenance.
MaintenanceNo ordinary maintenance is necessary.
Weights2The weight of the partition is 45/70 kg /m . according to the finishing of the surface and the sound proofing
level.
Laboratory TestsThe very high performance of MAXPARETE HSP MATIC sound proofing, the fire tests, the quality of the materials and of the productive process are verified and tested by the main European Laboratories.
MAXPARETE HSP MATIC has obtained sound proofing and fire reaction certificates from CSI and Ministero dell'Interno homologation for the fire reaction.
Features
MAXPARETE HSP MATIC - Features - 3
Features
Elements
STANDARD ELEMENTThe standard element represents the typical element used to close the different rooms. Elements are locked in shut position by means of two movable seals which are simultaneously hand or electrically operated by a control inserted in the rabbet; the seals are pushed against the floor and the rail, so that the wall space is hermetically closed. The width of the elements is between 700 and 1200 mm (between 700 and 1250 mm only for elements with coverings in High Pressure Laminate). By request we can supply elements with greater width.
For elements with 55 dB and 57 dB sound proofing thickness increases from 106 / 110 to 126 mm.
SELF-BEARING STANDARD ELEMENTOnce the element is put in position and locked, it can lighten his weight the overhanging structure. This way, the load-bearing structures are burdened by the elements weight only during sliding operations (i.e. only one element at a time). It is very important that each element is correctly placed in position perfectly perpendicular and aligned with others before locking. The standard width of the elements is between 700 and 1200 mm (between 700 and 1250 mm in case of coverings in High Pressure Laminate). By request we can supply elements with greater width. It is not possible to produce self-bearing expander elements and self-bearing elements with pass doors inserted.
EXPANDER ELEMENTThe opening and closing manoeuvres of the walls are effectuated by means of the expander element, always installed laterally. This one is the first one to be unlocked when you need to open the partitions and stack the elements and the last one to be locked when you need to close them. The expander element is produced in two versions - MONODIRECTIONAL and MULTIDIRECTIONAL - with variable width between 850 and 1650 mm.
For elements with 55 dB and 57 dB sound proofing thickness increases from 145 to 166 mm.
ELEMENT WITH GLAZED VISION PANELFollowing the standard element characteristics it is possible to insert in each element a glazed vision panel with different measures and finishings. Also in this case elements are locked in shut position by means of two movable seals which are simultaneously hand operated by a control inserted in the rabbet; the seals are pushed against the floor and the rail, so that the wall space is hermetically closed. Elements width is as previously stated for standard elements.
Every element is 106 / 110 mm thick and is not available in 55 and 57 dB versions.
SINGLE PASS DOOR ELEMENTPass doors may be fitted to any intermediate element except for the telescopic closure element. The elements where we can insert a pass door have a fixed width of 1220 mm and allow a pass door wing of 900 with an height of 2120 mm. The thickness of the pass doors is 106 mm. By request we can supply elements with special measures.
This type of elements is not available in 55 and 57 dB versions.
MAXPARETE HSP MATIC - Features - 4
DOUBLE PASS DOOR ELEMENTFor the series with double ball bearing trolleys we can also supply a double pass door. This couple of elements has a standard total width of 2140 or 2340 mm and allows the insertion of 1800 mm doors with an height of 2120 mm. Pass door thickness is 106 mm. By request we can supply elements with special measures.
Double pass door are also available as "compact modules", i.e. with a standard total width of 2140 mm and 1800 mm doors with an height of 2120 mm.
This type of elements is not available in 55 and 57 dB versions.
PASS DOOR ELEMENT INSERTED IN THE WALLIn order to guarentee the passage between two or more rooms partitioned by MAXPARETE HSP MATIC, we can produce a pass door element inserted in the wall. This type of element has no trolleys and is laterally fixed to one of the existing walls. Pass door element is 3000 mm high maximum and with a wing 106 mm thick and 900 mm maximum width.
This type of elements is not available in 55 and 57 dB versions.
Features
MAXPARETE HSP MATIC - Features - 5
Features
Tracks
Tracks are in EN AW 6005/A high resistance aluminium. The manoeuvre of the panels is easy and you can do it without effort. The ball bearing trolleys slide with precision in the aluminium track. The different typologies and the different utilization ways of the tracks are shown here below:
TRACK TYPE 100Suitable for monodirectional stacking scheme - Utilizing 1 trolley type 10 for heights up to 3,5 m
TRACK TYPE 800Suitable for multidirectional stacking scheme - Utilizing 2 trolleys type 80 for heights up to 6,5 m
TRACK TYPE 1000Suitable for multidirectional stacking scheme- Utilizing 2 trolleys type 1000 for heights from 6,5 m
MAXPARETE HSP MATIC - Sheet 2.1 - Rev.01
WorkingScheme
Sections
Standard Element - Vertical Section
MAXPARETE HSP MATIC - Sheet 3.1 - Rev. 01
Sections
Horizontal Section Standard Element
MAXPARETE HSP MATIC - Sheet 3.2 - Rev. 02
106 m
m
Aluminium Profile
Soft PVC Profile(by request)
Soft Rubber Profile
Finishing Profile
"VISIBLE" VERTICAL ALUMINIUM TRIMS
"NOT VISIBLE" VERTICAL ALUMINIUM TRIMS
Aluminium Profile
Soft Rubber Profile
Finishing Profile
Soft PVC Profile(by request)
110 m
m
Sections
Seal and Movement Standard Element
MAXPARETE HSP MATIC - Sheet 3.3 - Rev. 01
CENTRAL MOVEMENT GROUP
UPPER SEAL GROUP
LOWER SEAL GROUP
Trolley/s
MOTORE-P MTI 24V
Sections
Standard Element with Extra Cross-bars - for heights more than 3060 mm
MAXPARETE HSP MATIC - Sheet 3.4 - Rev. 01
Sections
Standard Element without Frame - for heights less than 3060 mm
MAXPARETE HSP MATIC - Sheet 3.5 - Rev. 01
M1
M2
RXTX
Sections
Self-bearing Standard Element - only for heights less than 3500 mm
MAXPARETE HSP MATIC - Sheet 3.6 - Rev. 01
Multiple ElasticAdjustable Parts
M1
M2
RXTX
Sections
Vertical Uprights - Horizontal Section - Thickness 106 mm
MAXPARETE HSP MATIC - Sheet 3.7 - Rev. 03
Finishing Profile
PVC Profile
Aluminium Profile
Commander
100 mm (minimum)
110 m
m
Sections
Element with Glazed Vision Panel - Horizontal Section
MAXPARETE HSP MATIC - Sheet 3.8 - Rev. 01
Aluminium Profile
Aluminium Profile
Double Glasses
Double Glasses
Curtain
Sections
MAXPARETE HSP MATIC - Sheet 3.9 - Rev. 01
Element with Glazed Vision Panel - Vertical Section
Aluminium Profile
Double Glasses
Sections
Standard HSP Element 55 dB - Sections
MAXPARETE HSP MATIC - Sheet 3.10 - Rev. 03
Covering Panel - Th. 18 mm
Sound Absorber
Sound Proof Sheet
Horizontal Cross Section
Vertical Cross Section
126
126
Sections
MAXPARETE HSP MATIC - Sheet 3.11 - Rev. 03
Expander Element 55 dB - Sections
Horizontal Cross SectionVertical Cross Section
126
166
Sections
MAXPARETE HSP MATIC - Sheet 3.12 - Rev. 03
Standard HSP Element 57 dB - Sections
Covering Panel - Th. 18 mm
Sound Absorber
Sound Proofing Sheet
Horizontal Cross Section
Vertical Cross Section
126
126
Sections
Panel Joint - Vertical Section
In case of elements with two or more overlapping panels, the panel joint may be with tongue or with aluminium profile.
18 mmUpper Panel
Lower Panel
Flap for panel junction
18 mm
6 m
m
Upper Panel
Lower Panel
Panel Joint Profile(in Aluminium)
Panel Joint
MAXPARETE HSP MATIC - Sheet 3.13 - Rev. 01
Elements
MAXPARETE HSP MATIC - Sheet 4.1 - Rev. 02
Elements
Standard Element ExpanderElement
Element withglazed vision
panel- single glass -
Element withglazed vision
panel- double glass -
Double Pass Door Elementdoor thickness 106 mm
Pass Door Elementdoor thickness
106 mm
Pass Door ElementInserted in the Wall
Elements
MAXPARETE HSP MATIC - Sheet 4.2 - Rev. 02
Standard Element
Width of Standard Elements between 700 and 1200 mm (between 700 and 1250 mm only for elements with finishings in High Pressure Laminate)
Emergency Control
Elements
MAXPARETE HSP MATIC - Sheet 4.3 - Rev. 02
Expander Element
Emergency Control
110
SERIES
STROKE 100 mm
STROKE 170 mm
200 mmSTROKE
STROKE 250 mm
STROKE 300 mm
S
100
170
200
250
300
The expander element is produced in two versions - MONODIRECTIONAL and BIDIRECTIONAL - with variable width (850 mm min / 1650 mm max) and with stroke from 100 to 300 mm.
Elements with 200 and 300 mm stroke are non standard.
F
260
330
360
410
460
146
95
0 m
m
Elements
MAXPARETE HSP MATIC - Sheet 4.4 - Rev. 01
10 mm
Element with Glazed Vision Panel - Single Glass
Width as specified for standard elementsControl height may vary according to glass dimensions
Aluminium Glass Fixing(in MDF for non standard glass thickness)
Single Glass
Emergency Control
23
5 m
m
56
0 m
mm
inim
um
200 mmminimum
200 mmminimum
22
0 m
mm
inim
um
Elements
MAXPARETE HSP MATIC - Sheet 4.5 - Rev. 01
38 mm
Element with Glazed Vision Panel - Double Glass
Aluminium Glass Fixing(in MDF for non standard glass thickness)
Double Glass
23
5 m
m
200 mmminimum
200 mmminimum
22
0 m
mm
inim
um
56
0 m
mm
inim
um
Emergency Control
Width as specified for standard elementsControl height may vary according to glass dimensions
Elements
MAXPARETE HSP MATIC - Sheet 4.6 - Rev. 02
Pass Door Element - Door thickness 106 mm
STANDARD DIMENSIONS
Elementwidth
1220 mm
Doorheight
2120 mm
Doorwidth
900 mm
Emergency Control
Sliding bar
Elements
MAXPARETE HSP MATIC - Sheet 4.7 - Rev. 04
Double Pass Door Element - Door thickness 106 mm
Sliding bar
EmergencyControl
Elementwidth
2 x 1170 mm2 x 1070 mm
Doorheight
2120 mm2120 mm
Doorwidth
1800 mm1800 mm
Modules
StandardCompact
STANDARD MEASURES
Elements
MAXPARETE HSP MATIC - Sheet 4.8 - Rev. 02
Pass Door Element inserted in the Wall
Maximum door width: 900 mmMaximum height under the track: 3000 mm
Elements
MAXPARETE HSP MATIC - Sheet 4.9 - Rev. 00
Commander
TracksandCoverings
Track Type 100
MAXPARETE HSP MATIC - Sheet 5.1 - Rev. 02
Suitable for MONODIRECTIONAL stacking schemeutilizing 1 trolley type 10 for heights up to 3,5 m
150 m
m m
inim
um
101 mm
80 m
m
EN AW 6005/Aaluminium track
140 mm minimum
TracksandCoverings
Track Type 100 - With Covering
MAXPARETE HSP MATIC - Sheet 5.2 - Rev. 03
Suitable for MONODIRECTIONAL stacking schemeutilizing 1 trolley type 10 for heights up to 3,5 m
Track covering with the samefinishings as the operable partition
Fixing screws arealways suggested
EN AW 6005/Aaluminium track
Gasket
106 mm
Fin
ishin
g P
anel
Aco
ust
ic b
arr
ier
TracksandCoverings
Track Type 800
MAXPARETE HSP MATIC - Sheet 5.3 - Rev. 02
EN AW 6005/Aaluminium track
170 m
m m
inim
um
101 mm
107 m
m
140 mm minimum
Suitable for MULTIDIRECTIONAL stacking schemeutilizing 2 trolleys type 80 for heights up to 6,5 m
TracksandCoverings
Track Type 800 - With Covering
MAXPARETE HSP MATIC - Sheet 5.4 - Rev. 03
Suitable for MULTIDIRECTIONAL stacking schemeutilizing 2 trolleys type 80 for heights up to 6,5 m
Fixing screws arealways suggested
Track covering with the samefinishings as the operable partition
EN AW 6005/Aaluminium track
106 mm
Gasket
Fin
ishin
g P
anel
Aco
ust
ic b
arr
ier
TracksandCoverings
Track Type 1000
MAXPARETE HSP MATIC - Sheet 5.5 - Rev. 02
Suitable for MULTIDIRECTIONAL stacking schemeutilizing 2 trolleys type 1000 for heights from 6,5 m
200 m
m m
inim
um
117 m
m
140 mm minimum
118 mm
EN AW 6005/Aaluminium track
MAXPARETE HSP MATIC - Sheet 6.1 - Rev. 02
TracksAnchorageSystems
Track Anchorage with Iron Profile
Welding
Iron Profile(properly dimensioned)
MAXPARETE HSP MATIC - Sheet 6.2 - Rev. 02
TracksAnchorageSystems
Track Anchorage with Rawplugs
M8 Screw min.(Rawplugs properly
dimensioned)
Reinforced Concrete Slab
MAXPARETE HSP MATIC - Sheet 6.3 - Rev. 01
TracksAnchorageSystems
Track Anchorage with Rawplugs and Tensioners
Intermediate Plate
45° Min.
Square
50/1
00 m
m M
ax
Tensioner
Iron Tensioner
MAXPARETE HSP MATIC - Sheet 6.4 - Rev. 01
TracksAnchorageSystems
Track Anchorage with Rawplugs and Stiffenings Plates
Stiffening Plate
Counterplate
Intermediate Plate(if applicable)
MAXPARETE HSP MATIC - Sheet 6.5 - Rev. 01
TracksAnchorageSystems
Suspended Track Anchorage
"C" Profile
MAXPARETE HSP MATIC - Sheet 7.1 - Rev. 01
StackingSchemes
Stacking Scheme “1MON”
Distended Wall
Stacking Schemeon the wall axis
Only for Walls high < 3500 mm
MAXPARETE HSP MATIC - Sheet 7.2 - Rev. 01
StackingSchemes
Stacking Scheme “1BAT”
Distended Wall
Stacking Schemeon the wall axis
Only for Walls high < 3000 mm
MAXPARETE HSP MATIC - Sheet 7.3 - Rev. 01
StackingSchemes
Stacking Scheme “2PDN”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.4 - Rev. 01
StackingSchemes
Stacking Scheme “2PAR”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.5 - Rev. 01
StackingSchemes
Stacking Scheme “2FAS”
Distended Wall
Stacking Schemeout the wall axis
150 mm
MAXPARETE HSP MATIC - Sheet 7.6 - Rev. 01
StackingSchemes
Stacking Scheme “2FAL”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.7 - Rev. 01
StackingSchemes
Stacking Scheme “2FAM”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.8 - Rev. 01
StackingSchemes
Stacking Scheme “2PDR”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.9 - Rev. 01
StackingSchemes
Stacking Scheme “2AL1”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.10 - Rev. 01
StackingSchemes
Stacking Scheme “2AL2”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.11 - Rev. 01
StackingSchemes
Stacking Scheme “1K-01”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.12 - Rev. 01
StackingSchemes
Stacking Scheme “1K-02”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.13 - Rev. 01
StackingSchemes
Stacking Scheme “1K-03”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.14 - Rev. 01
StackingSchemes
Stacking Scheme “1K-04”
Distended Wall
Stacking Schemeout the wall axis
MAXPARETE HSP MATIC - Sheet 7.15 - Rev. 01
StackingSchemes
Stacking Scheme “1K-05”
Distended Wall
Stacking Schemeout the wall axis
TrolleysandTracks
Series 100 - Trolleys and Tracks
MAXPARETE HSP MATIC - Sheet 8.1 - Rev. 02
TrolleysandTracks
Series 800 - Trolleys and Tracks
MAXPARETE HSP MATIC - Sheet 8.2 - Rev. 02
TrolleysandTracks
Series 1000 - Trolleys and Tracks
MAXPARETE HSP MATIC - Sheet 8.3 - Rev. 02
IdeasforPlanning
Which space do I need to divide?
Which supporting structures do I need?
How many operable partitions do I need?
Which type of activity will be hold in the desired premises?
How much room is available to stack the movable wall elements?
MAXPARETE HSP - Planning - 1
Oddicini Industrie S.p.A. offers a wide range of versions of MAXPARETE HSP MATIC operable partitions, each one featuring its own range of options.
Before consulting your Oddicini agent we suggest you a planning that allows you to make the right choices and enables us to supply you with the product that best suit your requirements.
If you have to divide a specific area, you need to decide how many spaces you wish to create and their volumes. Once examined the existing space carefully, you should consider the elements that might interfere with the installation or the movement of the partitions, such as windows, columns, airconducts or pieces of furniture. You should assess if all the spaces you will create are suitably equipped with the services necessary for your activities. Is there a sufficient lighting system? Air conditioning? Electricity? All these considerations could lead to variations in the division you originally planned.
Most types of operable partitions are likely to depend on the load bearing elements (concrete soffits or ceilings) of the building. A verification of the soffit structure available or expected is necessary so to make sure it is fit for the anchorage of the system. In order to establish if the structure is adequate to support an operable partition it is sometimes advisable to consult a professional i.e. a structural engineer or an architect. In case the bearing structure was proved to be not suitable, there are self-supporting versions of the operable partitions adapted to transfer part of the total weight of the system to the floor so to lighten the weight applied to the soffit.
Estimate how many partitions will be necessary and their approximate dimensions; your Oddicini agent will help you at a second stage to precisely assess your requirements.
The answer to this question will enable us to determine the required level of acoustic performances. A classroom will require, for instance, a lesser need for acoustic insulation than a concert hall. The higher is the demand for acoustic insulation, the more expensive will be the operable partition.
It often happens that a high soundproofing is requested without taking into consideration the soundproofing of the area as a whole. The walls of a room where an operable partition is installed should not have a soundproofing level not lesser than the partition itself. For more specific details on acoustic performances, please ask for Oddicini Technical Anthology or our cd-rom.
The position of the stacking area can enormously influence the final layout of the operable partition. Decide the areas where the wall elements will be stacked and parked when the partition is not in use.
Typically these are stored at one of the two extremities of the partition. If there is enough space, the elements of the partition can be moved in a dedicated area of collection by means of additional parts of track.
IdeasforPlanning
MAXPARETE HSP - Planning - 2
Do I need special finishes?
Do I need special features?
The price of MAXPARETE HSP MATIC is influenced by the type of finish. The standard finishes include melamine, high pressure laminates (HPL), and various types of chipboard.
Special vinyl or fabric coverings and wood veneers of different essences are also available upon request.
Verify the safety features and standards to which the premises must conform to the required class of fire reaction and fire resistance of the partitions, the required number and dimensions of pass doors and/or emergency exits.