technical profile §undyne - kelair pumps · 2019-11-14 · technical profile gsa/gsi frame i...

4
Technical Profile GSA/GSI frame I Magnet drive end suction centrifugal pumps to ASME B73.3 / ISO 2858 / DIN. EN 22858: 1993 A versatile range of general seice pumps designed to cover a wide duty and application base using the minimum of pump models by maximising interchangeability of components. ailable within the range is the GSA (ASME standard pump) and the GSI (ISO DIN standard pump). A GSL option is available for temperatures down to -100 ° C / -1S0 ° F. The GSA/ (ASME) and GSI (ISO) product covers a hydraulic range that is split between three frame sizes, Frames 0, I, & II. The pumps are offered with a range of Synchronous Magnet Drives rated to match prime mover peormance, hence specifications of all denominations can be catered r. This range is based on sizes conforming to ANSI & ISO peormance and dimensional standards. The standard materials of construction are Stainless Steel with silicon carbide internal bearings. Peormance of the GSA/GSI frame I pumps 80 2900 min- 1 60 @ @ 250 200 E 40 \ I\ �1 150 ' @ " \ 100 20 0 0 4 6 2 3 8 10 4 5 6 8 10 20 30 40 60 Pump model Reference GSA GSI 1 2 3 1.5 X 1 X 6H 50-32-160H 3 X 1.5 X 6H 65-50-160H 3 X 2 X 6 80-65-160 CE@ ' �I I ' \ u 50 0 20 30 40 50 80 100 100 200 400 Reference GSA GSI 4 5 6 1.5 X 1 X 8 50-32-200 3 X 1.5 X 8H 65-40-200H 80-50-200 §undyne Design range limits The GSA/GSI pump is designed to operate from -40 ° C up to +260 ° C/ - 40 ° F up to +500 ° F without the need r any ancillary cooling medium. Design working pressure is 18.9 bar/ 275 psi. Solids handling The unit is capable of handling solids up to 5% w/w with 150 microns. Options Materials of construction Weed pas Alloy 20, Alloy C, Alloy B Internal bearings SiC/ Carbon Gaskets PTFE/ Graphite Other options casing drains flanged or screwed Jacketed pump casing Coupling housing drain Large range of pump protection

Upload: others

Post on 21-Apr-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Technical Profile §undyne - Kelair Pumps · 2019-11-14 · Technical Profile GSA/GSI frame I Magnet drive end suction centrifugal pumps to ASME B73.3 / ISO 2858 / DIN. EN 22858:

Technical Profile

GSA/GSI frame I Magnet drive end suction centrifugal pumps

to ASME B73.3 / ISO 2858 / DIN. EN 22858: 1993

A versatile range of general service pumps designed to cover a

wide duty and application base using the minimum of pump

models by maximising interchangeability of components.

Available within the range is the GSA (ASME standard

pump) and the GSI (ISO DIN standard pump). A GSL option

is available for temperatures down to -100°C / -1S0°F.

The GSA/ (ASME) and GSI (ISO) product covers a hydraulic range that is split between three frame sizes, Frames 0, I, & II. The pumps are offered with a range of Synchronous Magnet Drives rated to match prime mover performance, hence specifications of all denominations can be catered for.

This range is based on sizes conforming to ANSI & ISO performance and dimensional standards.

The standard materials of construction are Stainless Steel with silicon carbide internal bearings.

Performance of the GSA/GSI frame I pumps

80

2900 min-1

60

@ ............ I\.. @ � r-,... .....

250

200

E

'g 40 \ I\ �1 150 ¢:Cl)

::c: G) ' @ "\ "C

RI Cl)

100 ::c:

20

� 00

� U::: 4 6

2 3

8 10

4 5 6 8 10

20 30 40 60

Pump model

Reference GSA GSI 1 2 3

1.5 X 1 X 6H 50-32-160H

3 X 1.5 X 6H 65-50-160H

3 X 2 X 6 80-65-160

CE@

j_' �I

I "3' '

� \.::, I/ u

50

0

20 30 40 50 80 100

100 200 400

Reference GSA GSI 4 5 6

1.5 X 1 X 8 50-32-200

3 X 1.5 X 8H 65-40-200H

80-50-200

§undyne

Design range limits The GSA/GSI pump is designed to

operate from -40°C up to +260°C / -

40°F up to +500°F without the need

for any ancillary cooling medium.

Design working pressure is 18.9 bar/

275 psi.

Solids handling The unit is capable of handling solids

up to 5% w/w with 150 microns.

Options

Materials of construction Wetted parts Alloy 20,

Alloy C, Alloy B

Internal bearings SiC / Carbon

Gaskets PTFE / Graphite

Other options casing drains flanged or screwed

Jacketed pump casing

Coupling housing drain

Large range of pump protection

Page 2: Technical Profile §undyne - Kelair Pumps · 2019-11-14 · Technical Profile GSA/GSI frame I Magnet drive end suction centrifugal pumps to ASME B73.3 / ISO 2858 / DIN. EN 22858:
Page 3: Technical Profile §undyne - Kelair Pumps · 2019-11-14 · Technical Profile GSA/GSI frame I Magnet drive end suction centrifugal pumps to ASME B73.3 / ISO 2858 / DIN. EN 22858:
Page 4: Technical Profile §undyne - Kelair Pumps · 2019-11-14 · Technical Profile GSA/GSI frame I Magnet drive end suction centrifugal pumps to ASME B73.3 / ISO 2858 / DIN. EN 22858:

HMD Kontro GSA/GSI F1 1.0 5/12 A4 Eng.

Sundyne Headquarters:Sundyne, LLC 14845 West 64th AvenueArvada, Colorado 80007USA1-866-SundynePhone: 1.303.425.0800Fax: 1.303.425.0896www.sundyne.com

Sundyne China:Building 1, No. 879 Shen Fu RoadXinZhuang Industrial ZoneMin Hang DistrictShanghai, China 201108Phone: +8621 5055 5005Fax: +8621 5442 5265

Sundyne France:Sundyne International S.A.13-15, Boulevard Eiffel - B.P. 3021604 Longvic CedexFrancePhone: +33 380 38 33 00Fax: +33 380 38 33 66

Sundyne Spain:Sundyne Marelli Bombas, S.R.L.Ctra. Madrid-Toledo, Km.30.845200 IllescasToledo, SpainPhone: +34 925 53 45 00Fax: +34 925 51 16 00

Sundyne United Kingdom:Sundyne HMDKontro Sealless Pumps, Ltd.Marshall RoadHampden Park Industrial EstateEastbourne East Sussex, BN22 9ANUnited KingdomPhone: +44 1323 452000Fax: +44 1323 503369Email: [email protected]

Worldwide Sales HeadquartersUnit 2 Harvington Business ParkHampden Park Industrial EstateBrampton RoadEastbourne East Sussex, BN22 9BNUnited KingdomPhone: +44(0) 1323 452125

All information provided issubject to change without notice.© 2013 Sundyne, LLC All Rights Reserved. Other logosand trade names are property oftheir respective owners.

COMPRESSORS

PUMPS

GENUINE PARTS

SERVICE