technicl i nforma t ion lamp data - light tubes · technicl i nforma t ion lamp data - light tubes...

7
198 TECHNICAL INFORMATION Lamp Data - Light tubes Light tubes Light tubes produce light when a starter generates an electrical pulse, which starts a discharge of gas in the tube. This discharge generates ultraviolet light that is transformed into visible light when it meets the fluorescent coating (light powder) in the tubes glass wall. Different light powders dictate the spectral characteristics. A current through the tube limits/increases the discharge process and so defines the luminous efficacy. Ljuskälledata – Lysrör Figure Type ILCOS ZVEI Base Wattage (W) Lumen(lm)* Luminous eff. (lm/W)** Colour temp. (K) Item. no. T5, Tube Ra>80 Economic lifetime 19000 hr FDH T16 G5 14 1200 96 2700 77000336 3000 77000335 4000 77000337 21 1900 100 2700 77000338 3000 77000339 4000 77000340 28 2600 104 2700 77000342 3000 77000343 4000 77000344 35 3300 104 2700 77000346 3000 77000347 4000 77000348 49 4300 100 2700 77000391 3000 77000390 4000 77000393 24 1750 83 3000 77000351 4000 77000381 39 3100 90 3000 77000384 4000 77000385 54 4450 93 3000 77000398 4000 77000388 80 6150 80 2700 77000395 4000 77000396 T5, Tube for cold surroundings Ra>80 Economic lifetime 19000 hr 54 4850 93 3000 77009010 4000 77009009 80 6800 88 3000 77009014 4000 77009015 T5, ”longlife” tube Ra>80 Economic lifetime 48000 hr 28 2600 104 3000 77000800 4000 77000805 49 4300 100 3000 77000804 4000 77000812 54 4450 93 3000 77000813 4000 77000810 80 6150 88 3000 77000811 4000 77000809 T5, Tube ECO 21 000 hr FDH T16 G5 13 1150 91 3000 77000323 4000 77000403 20 1650 83 3000 77000400 25 2600 103 3000 77000331 4000 77000407 32 3100 98 3000 77000333 4000 77000408 45 4100 92 3000 77000332 4000 77000409 50 4450 92 3000 77000354 73 6300 84 3000 77000355 4000 77000417 T8, Tube Ra>80 Economic lifetime 17000 hr (HF) 12000 hr (F) FD T26 G13 15 1000 67 2700 77000079 3000 77000080 4000 77000081 18 1350 75 2700 77000274 3000 77000275 4000 77000276 30 2450 82 2700 77000233 3000 77000324 4000 77000322 36 3350 93 2700 77000277 3000 77000278 4000 77000279 58 5200 90 2700 77000280 3000 77000281 4000 77000282 Miniature tube Economic lifetime 8000 hr FD T16 G5 8 400 50 2700 77000329 3000 77000298 4000 77000299 * Lumen values for T5 at 25ºC. Maximum luminance value is at 35ºC and is 10 - 14% higher. **Luminous efficacy is at maximum lumen values.

Upload: others

Post on 21-Mar-2020

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TECHNICL I NFORMA T ION Lamp Data - Light tubes · TECHNICL I NFORMA T ION Lamp Data - Light tubes ... HIT˝CRI MT HIT G12 ... HIT-CRI G12 35 3600 80+ 3000 77000310 70 7300 80+ 3000

198

Technical informaTion Lamp Data - Light tubes

Light tubesLight tubes produce light when a starter generates an electrical pulse, which starts a discharge of gas in the tube. This discharge generates ultraviolet light that is transformed into visible light when it meets the fluorescent coating (light powder) in the tubes glass wall.

Different light powders dictate the spectral characteristics. A current through the tube limits/increases the discharge process and so defines the luminous efficacy.

Ljuskälledata – Lysrör

Figure Type ILCOS ZVEI Base Wattage (W) Lumen(lm)* Luminous eff.(lm/W)** Colour temp. (K) Item. no.

T5, TubeRa>80

Economic lifetime 19000 hr

FDH T16 G5

14 1200 962700 770003363000 770003354000 77000337

21 1900 1002700 770003383000 770003394000 77000340

28 2600 1042700 770003423000 770003434000 77000344

35 3300 1042700 770003463000 770003474000 77000348

49 4300 1002700 770003913000 770003904000 77000393

24 1750 83 3000 770003514000 77000381

39 3100 90 3000 770003844000 77000385

54 4450 93 3000 770003984000 77000388

80 6150 80 2700 770003954000 77000396

T5, Tube for cold surroundings

Ra>80Economic lifetime

19000 hr

54 4850 933000 77009010

4000 77009009

80 6800 883000 77009014

4000 77009015

T5, ”longlife” tubeRa>80

Economic lifetime 48000 hr

28 2600 104 3000 770008004000 77000805

49 4300 100 3000 770008044000 77000812

54 4450 93 3000 770008134000 77000810

80 6150 88 3000 770008114000 77000809

T5, TubeECO

21 000 hrFDH T16 G5

13 1150 91 3000 770003234000 77000403

20 1650 83 3000 77000400

25 2600 103 3000 770003314000 77000407

32 3100 98 3000 770003334000 77000408

45 4100 92 3000 770003324000 77000409

50 4450 92 3000 77000354

73 6300 84 3000 770003554000 77000417

T8, TubeRa>80

Economic lifetime 17000 hr (HF)12000 hr (F)

FD T26 G13

15 1000 672700 770000793000 770000804000 77000081

18 1350 752700 770002743000 770002754000 77000276

30 2450 822700 770002333000 770003244000 77000322

36 3350 932700 770002773000 770002784000 77000279

58 5200 902700 770002803000 770002814000 77000282

Miniature tubeEconomic lifetime

8000 hrFD T16 G5 8 400 50

2700 770003293000 770002984000 77000299

* Lumen values for T5 at 25ºC. Maximum luminance value is at 35ºC and is 10 - 14% higher. **Luminous efficacy is at maximum lumen values.

Page 2: TECHNICL I NFORMA T ION Lamp Data - Light tubes · TECHNICL I NFORMA T ION Lamp Data - Light tubes ... HIT˝CRI MT HIT G12 ... HIT-CRI G12 35 3600 80+ 3000 77000310 70 7300 80+ 3000

199

Technical informaTionLamp Data - Compact light tubes

Compact light tubesA compact light tube is in reality just an ordinary tube that has been bent around on itself so you only need one lamp per fitting. There are two principle types. One has built-in starter (2 pin) and the other does not (4 pin). Note that for HF ballast or integrated emergency lighting you should always use 4 pin compact tubes as the HF ballast and emergency light units have their own ”starter” built in.

Lamp data – Compact light tubes

Figure Type ILCOS ZVEI Base Wattage(W) Lumen (lm) Luminous eff.

(lm/W)Colour temp.

(lm/W) Item no.

TC-S

Compact light tubes2 limb short

2 pinRa>80

Economic lifetime 10000 hr

FSD-I TC-S G23

7 400 572700 770003013000 77000318

9 600 673000 770003174000 77000286

11 900 822700 770002913000 77000316

TC-S

EL

Compact light tubes2 limb short

4 pinRa>80

Economic lifetime 13000 hr

FSD-E TC-SEL 2G7

7 400 572700 770001594000 77001040

9 600 672700 770001604000 77000294

11 900 823000 770004064000 77000295

TC-L

Compact light tubes2 limb long

Ra>804 pin

Economic lifetime 20000 hr (HF)15000 hr (F)

FSD-E TC-L 2G11

18 1250 692700 770001223000 770000564000 77000120

24 1800 752700 770001233000 770001214000 77000058

28 2700 963000 251032574000 25103258

36 2900 812700 770001243000 770000844000 77000086

FSDH-L TC-L 2G11

40 3500 87 3000 770000954000 77000096

55 4850 88 3000 770001364000 77000137

80 6500 81 3000 251033964000 25103397

TC-D

Compact light tubes4 limb, 2 pin

Ra>80Economic lifetime

10000 hr

FSQ-I TC-D

G24d-1

10 600 602700 770000153000 770000164000 77000017

13 900 692700 770000223000 770000194000 77000026

G24d-2 18 1200 672700 770000093000 770000104000 77000011

G24d-3 26 1800 692700 770002213000 770002194000 77000222

TC-D

EL

Compact light tubes4 limb, 4 pin

Ra>80Economic lifetime

13000 hr

FSQ-E TC-DEL

G24q-1

10 600 602700 770000973000 770000184000 77000098

13 900 692700 770000993000 770000024000 77000100

G24q-2 18 1200 672700 770000123000 770000134000 77000014

G24q-3 26 1800 692700 770002203000 770002174000 77000218

TC-R

Compact light tubes6 limb, 4 pin

Ra>80Economic lifetime

13000 hr

TC-R GR14q

14 1050 743000 77001208

4000 77001209

17 1250 74

3000 77001210

4000 77001211

Page 3: TECHNICL I NFORMA T ION Lamp Data - Light tubes · TECHNICL I NFORMA T ION Lamp Data - Light tubes ... HIT˝CRI MT HIT G12 ... HIT-CRI G12 35 3600 80+ 3000 77000310 70 7300 80+ 3000

200

Technical informaTion Lamp Data - Compact light tubes

Compact light tubesA compact light tube is in reality just an ordinary tube that has been bent around on itself so you only need one lamp per fitting. There are two principle types. One has built-in starter (2 pin) and the other does not (4 pin). Note that for HF ballast or integrated emergency lighting you should always use 4 pin compact tubes as the HF ballast and emergency light units have their own “starter” built in.

Lamp data – Circular tube

Figure Type ILCOS ZVEI Base Wattage (W) Lumen (lm) Luminous eff. (lm/W) Colour temp. (K) Item no.

T16�R T5 circular tube16 mmRa>80

Economic lifetime16000 hr

FCH T16-R 2GX13

22 18002700 770010003000 770010014000 77001003

40 32002700 770010053000 770010074000 77001009

55 42002700 770010113000 770010134000 77001015

Lamp data – Compact light tube

Figure Type ILCOS ZVEI Base Wattage (W) Lumen (lm) Luminous eff.(lm/W) Colour temp. (K) Item no.

TC-T

Compact light tubes6 limb, 2 pin

Ra>80Economic lifetime

10000 hr

FSM-I TC-T

GX24d-1 13 900 692700 770002523000 770002564000 77000253

GX24d-2 18 1200 692700 770002553000 770002544000 77000251

G24d-3 26 1800 692700 770004313000 770004294000 77001045

TC-T

EL

Compact light tubes6 limb, 4 pin

Ra>80Economic lifetime

13000 hr

FSM-E TC-TEL

GX24q-2 18 1200 672700 770001693000 770001734000 77000166

GX24q-3 26 1800 692700 770001703000 770001744000 77000165

GX24q-3 32 2400 752700 770001713000 770003194000 77000320

GX24q-4 42 3200 762700 770003653000 770003664000 77000367

GX24q-5 57 4300 752700 770003793000 770003684000 77000363

2G8-1 120 9000 75 3000 770003614000 77000362

TC-D

D/E

Compact light tubes2D, 2 pin

Economic lifetime 12000 hr

FS-I TC-DDGR8 16 1050 65 2700 77000139

GR8 28 2050 73 2700 77000178

FS-E TC-DD GRZ10d 18 1200 2700 77000146

Compact light tubes2D, 4 pin

Economic lifetime 12000 hr

FS-E TC-DD/E

GR10q 16 1050 65 2700 77000140

GR10q 28 2050 73 2700 77000184

GR10q 38 2850 75 2700 77000183

Page 4: TECHNICL I NFORMA T ION Lamp Data - Light tubes · TECHNICL I NFORMA T ION Lamp Data - Light tubes ... HIT˝CRI MT HIT G12 ... HIT-CRI G12 35 3600 80+ 3000 77000310 70 7300 80+ 3000

201

Technical informaTionLamp Data - Metal halide

Metal halideMetal halide lights produce light by starting an electrical discharge in argon gas between primary and secondary electrodes. This causes ionisation in the discharge tube so the discharge between the electrodes starts. This requires a high starting voltage. For this reason an external starter is used that gives start pulses of 1.5 – 4 kV. It can take up to 10 min. before the light has reached full light flux. Ceramic versions give more stable colour temperatures and color rendering throughout their lifetime.

Supplier definitions – Metal Halide

Figure ILCOS ZVEI BaseWattage

(W)GE Osram* Philips** Iwasaki Sylvania

HIT�CRIMT HIT G12

35 CMH 35/T HCI-T 35 CDM-T 3570 CMH 70 T HCI-T 70 CDM-T 70 MHT 70 HSI-T 70

150 ARC 150 HCI-T 150 CDM-T 150 CMI-T 150HIT�DE

MDHIT-DE

RX7s 70 CMH 70 TD HCI-TS 70 CDM-TD 70 HSI-TD 70150 ARC 150 HCI-TS CDM-TD 150 HSI-TD 150

Fc2 250 ARC 250 HQI-TS 250 MHN-TD 250 HSI-TD 250

MT HIT E40150 HCI-TT CDO-TT MT 150250 ARC 250/T HQI-T 250 HPI-T 250 MT 250 HSI-T 250400¹ ARC 400/T HQI-T 400 HPI-T plus 400 MT 400 HSI-T 400

HME

ME HIEE27

70 HQI-E 70 CDO-ET 70 MT 70 HSI-MP100 MXR 100 HQI-E 100 CDO-ET 100 HSI-MP 100150 HQI-E 150 MT 150

E40 250 ARC 250/D HQI-E 250 HPI-E 250 MT 250 HSI-S 400400¹ ARC 400/D HQI-E 400 HPI-E 400 MT 400 HSI-S 400

*Osram definition with Ceramic burner = HCI with Quartz burner= HQI. ** Philips definition with ceramic burner = CD, with Quartz burner = HPI.

Figure Type ILCOS ZVEI Base Wattage (W) Beam angleLight strength

(cd)Colour temp. (K) Item no.

HIPAR30

PAR 30 MR HIPAR 30 E2735

10 37000 3000 4188630 7000 3000 41887

7010 55000 3000 4162140 10000 3000 41620

HIPAR 51 HIPAR 51 GX1020 25 4000 2910 40314120 40 1700 2910 403140

Lamp data – Metal halide

Figure Type ILCOS ZVEI Base Wattage (W) Lumen (lm)* (Ra) Colourrendering Colour temp. (K) Item no.

HIT�CRI MiniatureSingle ended

CeramicMT HIT-CRI G12

35 3600 80+ 3000 77000310

70 7300 80+ 3000 770002646800 90+ 4200 77000314

150 13000 80+ 3000 7700026514500 90+ 4200 77000309

HIT-TC-CRI PGJ5 20 1650 85 3000 77001196

HIT�DE

Double endedCeramic MD

HIT-DE- CRI

RX7s70 6800 80+ 3000 77000266

6500 90+ 4200 77000312

150 14500 80+ 3000 7700026714400 90+ 4200 77000308

HIT�DEDouble ended

Quartz MD HIT-DE RX7s 70 5700 80+ 4000 77000182150 12000 80+ 4000 77000181

Fc2 250 20000 80+ 4200 77000112Tube formed

Ceramic MT HIT-CRI E27 70 7000 80+ 3000 77000106E40 150 14500 80+ 3000 77001039

Tube formedQuartz MT HIT E40

250 20000 90 5200 77000148400** 34000 60+ 4000 77001047400* 42000 65+ 3500 77001047400* 35000 90 5200 770001101000 8500 90 7250 770001181000 110000 65 3500 770001262000 180000 90 7250 770001152000 240000 65 4400 770001192000 210000 65 3800 77001204

HME

Elliptical formedDiffuse Ceramic**

ME HIE-CRI E27 70 6700 80+ 3000 77000106ME HIE-CRI E27 150 13700 90 3000 77000108

Elliptical formedDiffuse Quartz ME HIE

E27

100 7900 80 2900 77000023100 7700 80 4000 77001064150 11600 70 2900 77001060150 11500 80+ 4000 77001042

E40 400* 34000 90 5300 77000127400** 26000 90 5500 77000127

* Can be used with both Sodium (HS) and Metal Halide (HI) ballast. Lumen values are shown Sodium values. ** With Metal Halide ballast. *** Can be used in open luminaires.

Page 5: TECHNICL I NFORMA T ION Lamp Data - Light tubes · TECHNICL I NFORMA T ION Lamp Data - Light tubes ... HIT˝CRI MT HIT G12 ... HIT-CRI G12 35 3600 80+ 3000 77000310 70 7300 80+ 3000

202

Technical informaTion Lamp Data - High intensity sodium

High intensity sodiumHigh intensity sodium lamps do not require secondary electrodes. The Xenon gas is ionised with the help of an external starting ignitor that also starts the discharge of sodium vapour. Beyond this starting the operation is as with metal halide lamps.

Supplier definitions – Sodium lamps

Figure ILCOS ZVEI BaseWattage

(W)GE Osram Philips Iwasaki Sylvania

HSTST HST

E27 70 LU70/90/T NAV T 70 SON-T 70 SHP-T 70

E40

100 LU 100/..T NAV T 100 SON-T 100 NHT 100 SHP-T 100150 LU150/..T NAV T 150 SON-T 150 NHT 150 SHP-T 150250 LU250./T NAV T 250 SON-T 250 NHT 250 SHP-T 250400 LU400./T NAV T 400 SON-T 400 NHT 400 SHP-T 4001000 LU1000/T NAV T 1000 SON-T 1000 NHT 1000 SHP-T 1000

HSE

SE HSE

E2750 LU50/90/D NAV E 50 SON-E 50 NH 50 SHP-S 5070 LU70/90/D NAV E 70 SON-E 70 NH 70./HV/. SHP-S 70

E40

100 LU 100/..D NAV E 100 SON-E 100 NH 100 F SHP-S 100150 LU150/..D NAV E 150 SON-E 250 NH 150.. SHP-S 150250 LU250/..D NAV E 250 SON-E 250 NH 250.. SHP-S 250400 LU400/..D NAV E 400 SON-E 400 NH 400.. SHP 400

1000 LU1000/.D NAV E 1000 SON-E 1000 NH 1000

Lamp data – High intensity sodium

Figure Type ILCOS ZVEI Base Wattage (W) Lumen (lm) Luminous eff.(lm/W)

Colour temp. (K) Item no.

HSTTube formed

StandardRa=25Clear

ST HST

E27 70 5900 84 2000 77001017

E40

150 14500 97 2000 77001019250 27000 108 2000 77001021400 48000 120 2000 77001023

1000 130000 130 2000 770002061000 130000 130 2000 77001205

HSTTube formed

Long lifeHigh Output

Ra=25Clear

ST HST

E2750 4400 88 2000 7700021270 6500 93 2000 77000213

E40

100 10000 100 2000 77000214150 17500 117 2000 77000215250 33000 132 2000 77000216400 55500 139 2000 77000378600 90000 150 2000 77000377

HIT-DE Tube formedDouble ended SD HST-DE Rx7s

70 6800 96 2000 77001070150 15000 100 2000 77001069

HSE Elliptical formedStandardRa=25Diffuse

SE HSE

E2750 3500 70 2000 7700102770 5600 80 2000 77001029

E40

150 14000 93 2000 77001031250 25000 100 2000 77001033400 47000 117 2000 77001035

1000 120000 120 2000 77000116

HSEElliptical formed

Long lifeHigh Output

Ra=25Diffuse

SE HSE

E2750 3500 70 2000 7700000370 5600 80 2000 77000001

E40

100 9500 95 2000 77000226150 17000 113 2000 77000227250 32000 128 2000 77000228400 54000 135 2000 77000225

CityLightRa>50

STM HST E27 80 5600 70 3000 77001037SEM HSE PG12-3 80 6000 75 3000 77001036

Page 6: TECHNICL I NFORMA T ION Lamp Data - Light tubes · TECHNICL I NFORMA T ION Lamp Data - Light tubes ... HIT˝CRI MT HIT G12 ... HIT-CRI G12 35 3600 80+ 3000 77000310 70 7300 80+ 3000

203

Technical informaTionLamp Data - Incandescent halogen lamp

Incandescent halogen lampFrom a light technical point of view halogen lamps function in the same way as normal incandescent lamps. The difference lies in the fact that a halogen is added to prevent the vaporised tungsten from settling on the bulb and blackening it, but instead returns to the electrode. Since the problem of blackening is eliminated, smaller glass bulbs can be used, which are also stronger. This means that higher intensity in the lamp is possible. This raised pressure produces less vaporisation of the filament and so an even higher temperature The result is a significantly higher luminous efficacy compared to conventional incandescent lamps.

Lamp data – Low voltage halogen burner

Figure Type ILCOS ZVEI Base Wattage (W) Lumen (lm) Luminous eff. (lm/W) Colour temp. (K) Item no.

QT9 2 pin burnerUV blocked HSG QT9 G4

5 60 12 2900 7700035610 130 13 2900 7700018620 300 15 3000 77000199

QT12 2 pin burnerUV blocked HSG QT12 GY6,35

20 300 15 2900 7700019635 600 17 3000 7700019450 910 18 3000 7700019175 1450 19 3000 77000189

Lamp data – Low voltage reflector lamp

Figure Type ILCOS ZVEI Base Wattage (W) Beam angle Intensity (cd) Colour temp. (K) Item no.

QR�CBC

Cold light lampwith front glass

4000hrHRGI QR-CBC

GU5,351mm

20 10 5000 2900 7700003020 36 780 2900 7700002920 60 350 2900 7700104335 10 8000 3000 7700003335 24 3100 3000 7700003235 36 1500 3000 7700003135 60 700 3000 7700104150 10 1200 3000 7700003750 24 4400 3000 7700003650 36 2200 3000 7700003550 60 11000 3000 77000034

GU4

35mm

20 10 4500 2900 77001034QR�CBC

Miniature4000hr HRGI QR-CBC

20 36 700 2900 7700103235 10 8000 2900 7700103035 36 1350 2900 77001028

QR�CBC

AluminisedReflector

With front glass3000hr

HRGI QR-CBCGU5,351mm

20 10 3000 2900 7700046020 36 480 2900 7700046135 10 6000 2900 7700105035 36 1000 3000 7700046450 36 1450 3000 77000459

Lamp data – 230V reflector lamp

Figure Type ILCOS ZVEI Base Wattage (W) Beam angle Intensity (cd) Colour temp.

(K) Item no.

LEDspot GU10LED spot light

40 000h GU10 8 25 1900 3000 77001214

LED spot light40 000h GU10 8 40 950 3000 77001217

LEDspot GU10_2

CFL spot light15 000h GU10 7 45 70 2700 3800639

CFL spot light15 000h GU10 9 45 110 2700 3800640

CFL spot light15 000h GU10 11 45 125 2700 3800672

Page 7: TECHNICL I NFORMA T ION Lamp Data - Light tubes · TECHNICL I NFORMA T ION Lamp Data - Light tubes ... HIT˝CRI MT HIT G12 ... HIT-CRI G12 35 3600 80+ 3000 77000310 70 7300 80+ 3000

204

Technical informaTion Lamp Data - Incandescent halogen lamp

Incandescent halogen lampsIncandescent halogen lamps work in exactly the same way as ordinary incandescent lamps. The difference lies in the fact that a halogen is added, which prevents the vaporised tungsten from settling on the bulb and blackening it, but instead returns to the electrode. Since the problem of blackening is eliminated, smaller glass bulbs can be used which are stronger. This means that pressure is raised in the lamp. Increased pressure produces less vaporisation of the filament and so an even higher temperature is possible. The result is a significantly higher luminous efficacy compared to conventional incandescent lamps.

Lamp data – 230V halogen PAR lamp

Figure Type ILCOS ZVEI Base Wattage (W) Beam angle Intensity (cd) Colour temp. (K) Item no.

QPAR16Halo PAR16 CB HAG QPAR 16 GZ10 50 40 750 3000 77001026

Halo PAR16 Al GU10 50 40 800 3000 77001024

QPAR20 Halo PAR 20Cool Beam

HAG QPAR 20 E27 50 10 3200 3000 7700102250 30 1100 3000 77001020

Halo PAR 20Alu reflektor

HAG QPAR 20 E27 50 10 3000 3000 7700042550 30 1000 3000 77000426

QPAR20 Halo PAR 30Cool Beam

HAG QPAR 30 E27 75 10 7500 3000 7700101875 30 2400 3000 77001016

Halo PAR30Alu reflektor

HAG QPAR 30 E27 75 10 6900 3000 7700014275 30 2200 3000 77000143

Lamp data – 230V halogen tube

Figure Type ILCOS ZVEI BaseWattage

(W)Length (mm) Lumen (lm) Colour temp. (K) Item no.

HIT-DEHalogen

tube-double endedHDG QPAR 16 R7s

100 74,9 1600 3000 77000411150 74,9 2500 3000 77000413200 114,2 3200 3000 77000416300 114,2 5000 3000 77000414500 114,2 9500 3000 77000054