15
OHA MANAGEMENT RS-OHA: D1-D3 (Qecc) 192k bit/s for regenerator section management MS-OHA: D4-D12 (Qecc) 576k bit/s for multiplexer section management STM1 is the reference level for the section overhead. In STMxx the SOH is a STM1 SOH repeated xx times, however only the first STM1 is used for some bytes i.e. the D-bytes. Consequently Qecc capacity is the same for STM1 and STM16. SETTING UP AC1 OHA (SR1) See MA-196 pp.60-61 Fig. 35 Cable Connector Pin Numbers and Coding Pins. SR1 Slot 17, 11 or 5 Slot 15, 9 or 3 Management - Ethernet 32 Aggregate STM1 1 12 F-interface, V.28 2 13 Sync. 11 Tributaries 6-10 17-21 Tributaries - shared 22 User Channels (V.11) 23,24 29,30 Power Supply F-interface 27 33 EOW 28 24 For V.28 the following AC1 connector can be used for 9600k baud: V.28 Connector position 2, 13 Pin Pin Pin 1 8 15 2 9 \ENABLE 16 3 V.28_IN 10 17 V.28_OUT 4 11 18 GND 5 12 19 6 13 20 7 GND 14 GND 21 V.28 cable description: SHORT DB9 FEMALE TO PC (DTE) V.28 2,13 DB9 MALE TO MODEM(DCE) RxD 2 17 3 TxD 3 3 2 GND 5 7,9,14,18 5 # manage "show AC1_30 .AC1_XX provisionedEquipment \ \ENABLE must be tied to GND in order to Remove pins 3,4,6 and 7 on the AC1 AC1 PDH 2Mbit: 1-21 AC1 PDH 2Mbit: 1-21 V.28 OHA V.28 OHA

Upload: lynmuel-uy

Post on 02-Apr-2015

172 views

Category:

Documents


13 download

TRANSCRIPT

Page 1: Tellabs OHA Setup

OHA MANAGEMENTRS-OHA: D1-D3 (Qecc) 192k bit/s for regenerator section managementMS-OHA: D4-D12 (Qecc) 576k bit/s for multiplexer section managementSTM1 is the reference level for the section overhead. In STMxx the SOH is a STM1 SOH repeated xx times, however only the first STM1 is used for some bytes i.e. the D-bytes. Consequently Qecc capacity is the same for STM1 and STM16.

SETTING UP AC1 OHA (SR1)See MA-196 pp.60-61

Fig. 35 Cable Connector Pin Numbers and Coding Pins.

SR1 Slot 17, 11 or 5 Slot 15, 9 or 3Management - Ethernet 32Aggregate STM1 1 12F-interface, V.28 2 13Sync. 11Tributaries 6-10 17-21Tributaries - shared 22User Channels (V.11) 23,24 29,30Power Supply F-interface 27 33EOW 28 24

For V.28 the following AC1 connector can be used for 9600k baud:V.28 Connector position 2, 13

Pin Pin Pin1 8 152 9 \ENABLE 163 V.28_IN 10 17 V.28_OUT4 11 18 GND5 12 196 13 207 GND 14 GND 21

V.28 cable description:SHORT DB9 FEMALE

TO PC (DTE)V.282,13

DB9 MALETO MODEM(DCE)

RxD 2 17 3TxD 3 3 2GND 5 7,9,14,18 5

# manage "show AC1_30 .AC1_XX provisionedEquipment \rack 12 subrack 7 slot 9 adm1qOEE ohaConfiguration all attr"|grep v28

v28-NextSetup = "msTTPBidirectional ""12-7-9-1""" v28-NextTimingMode = oversampled v28-CurrentSetup = "msTTPBidirectional ""12-7-9-1""" v28-CurrentTimingMode = oversampled v28-PossibleSetup = {"rsTTPBidirectional ""12-7-9-2""",

In this example the use of MS OHA for DCN is disabled. (RS OHA is used by default)# manage "show AC1_30 .AC1_XX eCCConfiguration currentECCConfig"

currentECCConfig = { }

\ENABLE must be tied to GND in order to enable V.28

Remove pins 3,4,6 and 7 on the AC1 connector

AC1

PDH 2Mbit: 1-21

AC1

PDH 2Mbit: 1-21

V.28 OHAV.28 OHA

Page 2: Tellabs OHA Setup

Cable assemblies:User channelsV.28 channel One per module 9P DSUB WK-103X-10.0-01 REAR DATACOM 9P DSUB

25P DSUB WK-104X-01.0-01 REAR DATACOM 25P DSUBV.11 channel One per module Open ended

2x4 twisted pair AWG26stranded

WK-076Y-03.0-11 AC1, USERCH/MONITOR 3,0M

NOTE: Turn off flow control on relevant DCE and DTE's, i.e. terminal servers.TEX cards can only route in VC12 OH. The VC12 OH is low BW typically 4800 baud and tied to the VC12.The AC1 ADM has one V.28 interface only. East or West access can be configured in SW.If several hops must be routed a TEX card can provide the second V.28 interface.Alternatively V.11 can be used. Up to 3 V.11 interfaces can be accessed per card.

Page 3: Tellabs OHA Setup

SETTING UP AC4 OHA2See MA-124 pp. 83 and 145

OHA2 AUX Panel

The OHA2 AUX panel is available in 4 versions supporting different combinations of EOW, V.11 and V.28. These are CM4079, CM4079-1, CM4079-2, and CM4079-3.

Number Short DescriptionCM4079 OHA Panel for EOW/V.11 User ChannelsCM4079-1 OHA Panel for V.28/V.11 User ChannelsCM4079-2 OHA Panel for one EOW Channel and one

V.28/V.11 User ChannelCM4079-3 OHA Panel for DMTF- EOW and V.11

and V.28 User Channels

Connector 1-4 is DB15 male (DIN 41652) - cable DB15 female.Connector SYNC is DB9 male (DIN 41652).

Details - see below.

User Channel Connector

CM4079 CM4079-1 CM4079-2 CM4079-3

1 1 EOW voice, ch. 1, V.11EOW mgt., ch. 1, V.11 User ch. 1, V.28 EOW voice, ch. 2,

V.112 2 EOW voice, ch. 2, V.11 User ch. 1, V.28

EOW mgt., ch. 2, V.11 User ch. 2, V.28 EOW mgt., ch. 2, V.11 User ch. 2, V.283 User channel 3, V.11 (OHA2 only)4 User channel 4, V.11 (OHA2 only)

SYNC Two 120 ohm T3 synchronization inputs and two 120 ohm T4 synchronization outputs

With respect to interface and transport protocol the table above translates into:User Channel

ConnectorCM4079 CM4079-1 CM4079-2 CM4079-3

1 CH1, V.11, RS422 CH1, V.28, RS232 CH1, V.28, RS232 CH1, V.11, RS4222 CH2, V.11, RS422 CH2, V.28, RS232 CH2, V.11, RS422 CH2, V.28, RS2323 CH3, V.11, RS422 CH3, V.11, RS422 CH3, V.11, RS422 CH3, V.11, RS4224 CH4, V.11, RS422 CH4, V.11, RS422 CH4, V.11, RS422 CH4, V.11, RS422

SYNC Two 120 ohm T3 synchronization inputs and two 120 ohm T4 synchronization outputs

V.11 provides balanced communication, which is typical in telecommunication. V.28 provides unbalanced communication. V.28 can be converted to V.11 by the use of an RS232 to RS422 converter i.e. 222n9 from Patton Electronics.

4079

4079-1

Page 4: Tellabs OHA Setup
Page 5: Tellabs OHA Setup

4079-2

4079-3

OHA2 MODULE CM4054See MA124 pp187The OHA module provides, through two of the 18 STM-n interfaces:

A 64k bit/s User channel.A 576k bit/s User channel.

When using the OHA2 module it is possible to route the User channels between two of the 18 STM-n connections.Routing means that the User channel inputs from one STM-n interface are sent to the User Channel outputs of another STM-n interface via a buffer on the OHA2 module.The OHA2 module handles four STM-n interfaces - the two aggregate interfaces and two selectable tributary interfaces.Two of the four interfaces have User channel access on the OHA AUX panel, the other two interfaces are routed.The OHA module is configured by using the 12 DIP switches located on the card. Via the DIP switches it is possible to locate User channels either in the regenerator or in the multiplexer section of the STM-n SOH. The 576k bit/s user channels are located in DCCm (D4 - D12).

Page 6: Tellabs OHA Setup

TERMSERV - AC4 (OHA2 - NSC)V.28 to V.11 cable

Patton 222N9m with DB9 MALE Connector TO DS700

DB15 FEMALETO AC4

AC44079

Rx+ 2 Tx(4)Tx+ 4 Rx(4)Rx- 9 Tx(2)Tx- 11 Rx(2)GND SHIELD GND

AC4 - F2500 (OHA2 -NSC) SHORT DB15 FEMALE

TO AC4(OHA)DB9 FEMALETO F2500

F2500

RxD 9 2 TxTxD 11 3 RxGND 1 5 GGND

TRMSERV - AC4 (OHA2 - NSC)SHORT DB25 FEMALE

TO DS700DB15 FEMALE

TO AC4AC4

RxD 2 9TxD 3 11GND 7 1

TRMSERV - AC4 (OHA1 - BCS)SHORT DB25 FEMALE

TO DS700DB15 FEMALE

TO AC4AC4

RxD 2 4TxD 3 2GND 7 1

Page 7: Tellabs OHA Setup

FOCUS ESW DOWNLOAD ROM TFTP SERVERConfigure a TFTP server on NT or Unix and place the desired ESW images in the default directory.Create a TFTP load description file called "SCRIPT.ADM/CMC/ATX" with contents similar to the following:

AC1_30SCRIPT.ADM; serverdir=;SystemFile = ADQ30V84.BIN,98.02.13-11:34SystemFile = AD130V59.BIN,98.02.13-11:34;SystemFile = LMC30V69.BIN,98.02.13-11:34;DataFile= TABLFILE.LMC,01.01.08-20:56Action= RunCode

AC1_48SCRIPT.ADM; serverdir=SystemFile = AD148V19.BIN,00.06.12-11:40;SystemFile = LMC48V42.BIN,00.07.12-12:06;DataFile = TABLFILE.LMC,01.01.04-09:31Action = RunCode

TABLFILE.LMCLMC48V42.BIN,11LMC48V42.BIN,12LMC48V42.BIN,25LMC48V42.BIN,26LMC48V42.BIN,27LMC48V42.BIN,28LMC48V42.BIN,29LMC48V42.BIN,30LMC48V42.BIN,31LMC48V42.BIN,32LMC48V42.BIN,33LMC48V42.BIN,34LMC48V42.BIN,61LMC48V42.BIN,62LMC48V42.BIN,63LMC48V42.BIN,64LMC48V42.BIN,65

AC4_45SCRIPT.CMCSystemFile = CMC45V13.BIN,99.12.04-23:32SystemFile = SIM45V21.BIN,00.06.07-17:54SystemFile = SPM45V14.BIN,00.06.07-19:51SystemFile = SYN45V09.BIN,99.08.25-18:40DataFile = TABLFILE.LMC,00.06.07-15:47

TABLFILE.LMCSIM45V21.BIN, 7 SIM45V21.BIN, 8 SPM45V14.BIN, 6 SYN45V09.BIN, 10 SPM45V14.BIN, 38

On a Unix host the CASE of file names is significant. Similarly read access to "world" must be granted on the files. The date written in the SCRIPT.ADM/CMC/ATX file does not need to correspond to the actual file date. Line separation can be newline (UNIX) or carriage return and newline (WINDOS). TABLFILE.LMC is a text file specifying ESW module compatibility list. This file is not necessary in order to change the AC1 ADM module only.AC1 N-cards (AD130) does not support download of the LMC fileOn AC1 main and sub type needs to be re-entered if a Flash erase has been done - even if they are correctThe presence of OSI connectivity does by no means imply IP connectivity. I.e. embedded channels will only transport OSI packets. IP connectivity must therefore be ensured in advance. Test by downloading a file without clearing the file system first. LAN interface speed may need to be set. Make sure the image matches the module: BOOT: No 'SYSTEMFILE' for ADMQ in script-file!!! – 0.

SAMPLE PROCEDUREThe following AC1 example will clear Flash memory (the file system) and load new ESW from a TFTP server.The TFTP directory (/usr/tftpboot) contains:-rwxrwxrwx 1 root system 1077438 Jan 3 21:39 AD148V19.BIN-rwxrwxrwx 1 root system 1075685 Jan 3 21:39 ADQ48V53.BIN-rwxrwxrwx 1 root system 542304 Jan 3 21:39 LMC48V42.BIN

Page 8: Tellabs OHA Setup

-rwxrwxrwx 1 root system 160 Jan 8 19:32 SCRIPT.ADM-rwxrwxrwx 1 root system 291 Jan 4 20:16 TABLFILE.LMC

Configure a standard terminal (i.e. Hyperterm) to 9600 baud, 8 data bits, 1 stop bit, no parity and no flow-control. Attach the terminal to the Craft interface of the Focus element (below an AC1). Reset the NE. DSC Communications A/S Selftest Module ADM-1 Current Reset Cause: Hard reset. Provoke reset. RAM wire test PASSED Interrupt test PASSED Check Main board EEPROM PASSED PLD configuration OK. Not loaded PASSED Check Opto board EEPROM PASSED Check Flash board EEPROM PASSED BootPROM checksum PASSED FLASH PROM Check PASSED Ethernet loop back int. PASSED SAP Check PASSED STP Check PASSED HSCX Check PASSED Voltage Check PASSED Check Main Configuration PASSED Check Opto Configuration PASSED Check Flash Configuration PASSED Extended RAM Wire Test PASSED

Press ESC a couple of times during the self-test.DSC Communications A/S Selftest Module ADM-1 A C C E S S C O N T R O L ============================== <1> Enter Password <CTRL-B> Enter Flash EEPROM Setup <CTRL-L> Enter System SW Setup <CTRL-G> Start System Software

Enter Password

Press (1) and login to the NE.

Enter password "cre84dsc"DSC Communications A/S Selftest Module ADM-1 T E S T M E N U =================== <1> Select test\sequence <2> Set Parameters for tests <3> Status information <4> Setup sequence <5> HW Setup Main board <6> HW Setup Opto board <7> HW Setup Flash board <CTRL-C> Enter Command mode <CTRL-F> Enter Bootclient Setup <CTRL-L> Enter System SW Setup <CTRL-R> Run selected test\sequence <CTRL-G> Start system software SelectSelected test: 1 (Default) RAM Wire TestParameter status: Loop - N Error message - Y Halt on error - Y

Choose (5) for HW Setup Main board and press (N) for next page.EEPROM Hardware Setup - Main board 2 of 109 Boot Mode 0 System(0), Local pROBE(1), Remote pROBE(3), LoadFile(4), LoadScript(5)10 Default BaudRate 9600 Format: (ddddd) in Decimal11 Default Gateway IP 172.19.51.254 Format: (ddd.ddd.ddd.ddd) in IP12 Primary Network IP 172.19.51.211 Format: (ddd.ddd.ddd.ddd) in IP13 Primary Network Subnetmask 255.255.255.0 Format: (ddd.ddd.ddd.ddd) in IP14 Secondary Network IP 0.0.0.0 Format: (ddd.ddd.ddd.ddd) in IP15 Secondary Network Subnetmask 0.0.0.0 Format: (ddd.ddd.ddd.ddd) in IP16 Enable Poll of Primary Networkdriver Y Y or N17 Enable Poll of Secondary Networkdriver N Y or N(P)revius Page, (N)ext Page, (E)dit, (G)o Page and <CR> to Exit

Page 9: Tellabs OHA Setup

Press (E) to edit. Enter the line number and type the value subsequently. Change:

Boot Mode to LoadScript (5),Default Gateway IP (to the gateway IP address)Primary Network IP (assign a load state IP address to the NE)Primary Network Subnetmask (assign the IP subnet-mask defined by the gateway)

Press (N) for next.EEPROM Hardware Setup - Main board 3 of 1018 Ethernet Address 00:a0:82:10:0b:65 Format: (xx:xx:xx:xx:xx:xx) in Hex19 TFTP Host IP 172.19.51.88 Format: (ddd.ddd.ddd.ddd) in IP20 - 5V Conversion Factor 8 Format: (d)21 Neg 5V Max Voltage 5450 - 5V Max Voltage (dddd) in mV22 Neg 5V Min Voltage 4750 - 5V Min Voltage (dddd) in mV23 Pos 5V Conv Factor 8 + 5V Conversion Factor (d)24 Pos 5V Max Voltage 5250 + 5V Max Voltage (dddd) in mV25 Pos 5V Min Voltage 4750 + 5V Min Voltage (dddd) in mV26 Pos 3V Conv Factor 4 + 3V Conversion Factor (d)

(P)revius Page, (N)ext Page, (E)dit, (G)o Page and <CR> to Exit

Change TFTP Host IP (19) to the address of your TFTP server.

Press CR to return to the main menu:DSC Communications A/S Selftest Module ADM-1 T E S T M E N U =================== <1> Select test\sequence <2> Set Parameters for tests <3> Status information <4> Setup sequence <5> HW Setup Main board <6> HW Setup Opto board <7> HW Setup Flash board <CTRL-C> Enter Command mode <CTRL-F> Enter Bootclient Setup <CTRL-L> Enter System SW Setup <CTRL-R> Run selected test\sequence <CTRL-G> Start system software SelectSelected test: 1 (Default) RAM Wire TestParameter status: Loop - N Error message - Y Halt on error - Y

Press Ctrl-F for BootClient Setup. (If you want to erase flash memory/storage)Install C-bus-NiLan: 128.1.0.0pSOS has been (re)startedBootClient Mode: 127, HwMaintype: 2 - Next Sw:'AD148V19.BIN'File A: File state:1 Sw state:1 Name:'AD148V19.BIN'File B: File state:1 Sw state:0 Name:'LMC48V42.BIN'INITIALIZE Disc-system ? YesDiscparams: Type=4, Column=1, Row=2Discparams: Start=1000000, Size=400000, Access=1000000Discparams: Sectors=64, ChgLogSectors=2, Files=100, DirDepth=9++FlashCL: Flash memory is being prepared for disksystem. nSectorGroups(HEX): 40................................................................-Calc_NumberOfBlocks:15494** Forced INIT_VOL ** * Init_vol now *+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-* Init_vol OK *+-* Verify_vol OK *+- Files: 1 BITMAP.SYS 2048 Bytes, 8 Blocks, 1996.10.09 - 09:01 2 FLIST.SYS 13312 Bytes, 52 Blocks, 1996.10.09 - 09:01Creating file:'CODEFILE.SYS'+-+-+-Creating file:'TABLFILE.SYS'+-+-+-+-+-+-+-+-+-+-+- ** Re-enter SelfTest ** +-

Page 10: Tellabs OHA Setup

Press CR to return to the login menu:DSC Communications A/S Selftest Module ADM-1 A C C E S S C O N T R O L ============================== <1> Enter Password <CTRL-B> Enter Flash EEPROM Setup <CTRL-L> Enter System SW Setup <CTRL-G> Start System Software

Enter Password

Press Ctrl-L to verify correct NSAP address.Press Ctrl-G to restart the NE:Install C-bus-NiLan: 128.1.0.0pSOS has been (re)startedBootClient Mode: 5, HwMaintype: 2 - Next Sw:''File A: File state:0 Sw state:0 Name:''File B: File state:0 Sw state:0 Name:''Host IP address = 172.19.51.88Release label = ADM1_BOOT_04.01 ** Download Script **Discparams: Type=4, Column=1, Row=2Discparams: Start=1000000, Size=400000, Access=1000000Discparams: Sectors=64, ChgLogSectors=2, Files=100, DirDepth=9++-Calc_NumberOfBlocks:15494+-* Verify_vol OK *+- Files: 1 BITMAP.SYS 2048 Bytes, 8 Blocks, 1996.10.09 - 09:01 2 FLIST.SYS 13312 Bytes, 52 Blocks, 1996.10.09 - 09:01 4 CODEFILE.SYS 22 Bytes, 1 Blocks, 1996.10.09 - 09:01 5 TABLFILE.SYS 10 Bytes, 1 Blocks, 1996.10.09 - 09:01Type Script filename:<Timeout>TFTP-task initialized!Requesting 'SCRIPT.ADM' from host (172.19.51.88) ..Remote host and download file found: SCRIPT.ADM.TFTP download completed!File 'CODEFILE.SYS' already exists!!No file selected!+-+-+-Deleting 'AD148V19.BIN'+-+-+-Requesting 'AD148V19.BIN' from host (172.19.51.88) ..Remote host and download file found: AD148V19.BINCreating file:'DOWNLOAD.TMP'Loading: 1053 Kb<+-++*>-+-+-+-+-TFTP download completed!Download to flashprom PASSEDVerifying code..........................................Load from disc completed!Verify code PASSEDRename 'DOWNLOAD.TMP' to 'AD148V19.BIN'+-+-+-+-+-+-+-+-+-Rename file PASSED+-+-+-+-+-+-Copying pSOS 39bc bytes from 3f0f8 to be9b00 Done!Copying pHILE c4de bytes from 62170 to bed500 Done!Copying pREPC 6547 bytes from 6e650 to bf9a00 Done!Copying PASSED (Next addr: bfff80)+-+-+-..........................................Load from disc completed!Loading PASSEDTransfering control to the loaded code-image at:690422

+-+-+-+-Install C-bus-NiLan: 128.1.0.0

pSOS has been (re)started DSC Communications A/S Selftest Module ADM-1 Current Reset Cause: Hard reset. Provoke reset. RAM wire test PASSED Interrupt test PASSED Check Main board EEPROM PASSED PLD configuration OK. Not loaded PASSED Check Opto board EEPROM PASSED Check Flash board EEPROM PASSED BootPROM checksum PASSED FLASH PROM Check PASSED Ethernet loop back int. PASSED SAP Check PASSED STP Check PASSED HSCX Check PASSED Voltage Check PASSED Check Main Configuration PASSED Check Opto Configuration PASSED

Page 11: Tellabs OHA Setup

Check Flash Configuration PASSED Extended RAM Wire Test PASSEDInstall C-bus-NiLan: 128.1.0.0

pSOS has been (re)started

BootClient Mode: 0, HwMaintype: 2 - Next Sw:'AD148V19.BIN'File A: File state:1 Sw state:1 Name:'AD148V19.BIN'File B: File state:0 Sw state:0 Name:''Host IP address = 172.19.51.88Release label = ADM1_BOOT_04.01

** RUN System Software **Discparams: Type=4, Column=1, Row=2Discparams: Start=1000000, Size=400000, Access=1000000Discparams: Sectors=64, ChgLogSectors=2, Files=100, DirDepth=9++-Calc_NumberOfBlocks:15494+-* Verify_vol OK *+- Files: 1 BITMAP.SYS 2048 Bytes, 8 Blocks, 1996.10.09 - 09:01 2 FLIST.SYS 13312 Bytes, 52 Blocks, 1996.10.09 - 09:01 4 CODEFILE.SYS 34 Bytes, 1 Blocks, 2000.06.12 - 11:43 5 TABLFILE.SYS 22 Bytes, 1 Blocks, 2000.06.12 - 11:42 8 ECCCONF.CUR 804 Bytes, 4 Blocks, 1991.07.01 - 00:00 6 AD148V19.BIN 1077438 Bytes, 4209 Blocks, 2000.06.12 - 11:42 7 ECCCONF.DAT 804 Bytes, 4 Blocks, 1991.07.01 - 00:00Copying pSOS 39bc bytes from 3f0f8 to be9b00 Done!Copying pHILE c4de bytes from 62170 to bed500 Done!Copying pREPC 6547 bytes from 6e650 to bf9a00 Done!Copying PASSED (Next addr: bfff80)Selected file OK! (AD148V19.BIN)...............................................Load from disc completed!Loading PASSEDTransfering control to the loaded code-image at:690422+-Install C-bus-NiLan: 128.1.0.0

pSOS has been (re)started

USING TFTP IN IP MODESubsequent to network file load the NE accepts tftp requests. Since tftp does not support remote file listing this means the file name must be known in advance (wildcards are not supported). The following example shows retrieval of the NE database from an AC1:# cd /tmp# touch DATAB.DAT# chmod 666 DATAB.DAT# tftp 130.11.2.125 -get DATAB.DAT -mode binary (where IP address is the NE)

FOCUS-2-140Point-to-point 2-way communication channel merged into the optical line code. By means of the FOCUSNM200 tools the following options can be selected:1. RS232 V.24/V.28 serial asynchronous channel, with a sampling rate depending on the LTU line speed. See the module specific specifications.2. RS232 V.24/V.28 serial asynchronous channel. 9600 or 19200k bit/s. 1 start bit, 9 data bits. 1 start bit received => next 9 bits will be transmitted.

The Destination Address is a set of four (or five) parameters, which define the physical location of each NE (module):Network IDRack IDRack TypeSub Rack IDSub Rack TypeModule PositionModule Group

Sub Rack Type = SlimRack ID = is user-definable (from 1 to 254) but the same for all sub racks in a slim rackRack Type = 5, 6 or 8Sub Rack IDs = 1 to 8 inclusive (depending upon the rack type)Module Position = positions are numbered from left to right in each sub rack, starting with 1Module Group = not applicable for modules in slim sub racks