Parameter Name Parameter Name in CME Power Control Switch PWRCTRLSW Filter Length for UL RX_LEV ULLEVFILTLEN Filter Length for DL RX_LEV DLLEVFILTLEN Filter Length for UL Qual. ULQUAFILTLEN Filter Length for DL Qual. DLQUAFILTLEN MR. Compensation Allowed MRCOMPREG UL MR. Number Predicted ULPREDLEND DL MR. Number Predicted DLPREDLEND MAX Down Adj.Value Qual.Zone 0 MAXSTEP0 MAX Down Adj.Value Qual.Zone 1 MAXSTEP1 MAX Down Adj.Value Qual.Zone 2 MAXSTEP2 MAX Down Adj. PC Value by Qual. QUALSTEP MAX Up Adj. PC Value by RX_LEV MAXVALADJRX MAX Up Adj. PC Value by Qual. MAXADJPCVAL UL Qual. Bad Trig Threshold ULQUALBADTRIG UL Qual. Bad UpLEVDiff ULQUALBADUPLEV DL Qual. Bad Trig Threshold DLQUALBADTRIG DL Qual. Bad UpLEVDiff DLQUALBADUPLEV BTS PC Class BTSPWRNUM AMR PC Interval AMRPCADJPERIOD AMR Filter Length for UL RX_LEV AMRULLEVFTLEN AMR Filter Length for DL RX_LEV AMRDLLEVFTLEN AMR Filter Length for UL Qual AMRULQUAFTLEN AMR Filter Length for DL Qual. AMRDLQUAFTLEN AMR MR. Compensation Allowed AMRMRCOMPREG AMR UL MR. Number Predicted AMRULPREDLEND AMR DL MR. Number Predicted AMRDLPREDLEND AMR UL RX_LEV Upper Threshold AMRULSSHTHRED AMR UL RX_LEV Lower Threshold AMRULSSLTHRED AMR UL Qual. Upper Threshold AMRULQHTHRED AMR UL Qual. Lower Threshold AMRULQLOWTHRED AMR DL RX_LEV Upper Threshold AMRDLSSHTHRED AMR DL RX_LEV Lower Threshold AMRDLSSLTHRED AMR DL Qual. Upper Threshold AMRDLQHTHRED AMR DL Qual. Lower Threshold AMRDLQLTHRED AMR MAX Down Adj. Value Qual. Zone 0 AMRMAXSTEP0 AMR MAX Down Adj. Value Qual. Zone 1 AMRMAXSTEP1 AMR MAX Down Adj. Value Qual. Zone 2 AMRMAXSTEP2 AMR MAX Down Adj. PC Value by Qual. AMRQUALSTEP AMR MAX Up Adj. PC Value by RX_LEV AMRMAXVALADJRX AMR MAX Up Adj. PC Value by Qual. AMRMAXADJPCVAL AMR UL Qual. Bad Trig Threshold AMRULQUALBADTRIG AMR UL Qual. Bad UpLEVDiff AMRULQUALBADUPLEV AMR DL Qual Bad Trig Threshold AMRDLQUALBADTRIG AMR DL Qual Bad UpLEVDiff AMRDLQUALBADUPLEV AMR BTS PC Class AMRBTSPWRNUM PC Interval PCADJPERIOD UL RX_LEV Upper Threshold ULSSHIGHTHRED UL RX_LEV Lower Threshold ULSSLOWTHRED UL Qual. Upper Threshold ULQHIGHTHRED UL Qual. Lower Threshold ULQLOWTHRED DL RX_LEV Upper Threshold DLSSHIGHTHRED DL RX_LEV Lower Threshold DLSSLOWTHRED DL Qual. Upper Threshold DLQHIGHTHRED DL Qual. Lower Threshold DLQLOWTHRED

Upload: naeem4u4

Post on 09-Sep-2014

154 views

Category:

Documents


16 download

TRANSCRIPT

Page 1: Template

Parameter Name Parameter Name in CME Proposed Value

Power Control Switch PWRCTRLSW PWR2

Filter Length for UL RX_LEV ULLEVFILTLEN 4

Filter Length for DL RX_LEV DLLEVFILTLEN 4

Filter Length for UL Qual. ULQUAFILTLEN 4

Filter Length for DL Qual. DLQUAFILTLEN 4

MR. Compensation Allowed MRCOMPREG Yes

UL MR. Number Predicted ULPREDLEND 0

DL MR. Number Predicted DLPREDLEND 0

MAX Down Adj.Value Qual.Zone 0 MAXSTEP0 4

MAX Down Adj.Value Qual.Zone 1 MAXSTEP1 2

MAX Down Adj.Value Qual.Zone 2 MAXSTEP2 2

MAX Down Adj. PC Value by Qual. QUALSTEP 4

MAX Up Adj. PC Value by RX_LEV MAXVALADJRX 16

MAX Up Adj. PC Value by Qual. MAXADJPCVAL 8

UL Qual. Bad Trig Threshold ULQUALBADTRIG 4

UL Qual. Bad UpLEVDiff ULQUALBADUPLEV 5

DL Qual. Bad Trig Threshold DLQUALBADTRIG 4

DL Qual. Bad UpLEVDiff DLQUALBADUPLEV 5

BTS PC Class BTSPWRNUM 16

AMR PC Interval AMRPCADJPERIOD 3

AMR Filter Length for UL RX_LEV AMRULLEVFTLEN 4

AMR Filter Length for DL RX_LEV AMRDLLEVFTLEN 4

AMR Filter Length for UL Qual AMRULQUAFTLEN 4

AMR Filter Length for DL Qual. AMRDLQUAFTLEN 4

AMR MR. Compensation Allowed AMRMRCOMPREG YES

AMR UL MR. Number Predicted AMRULPREDLEND 0

AMR DL MR. Number Predicted AMRDLPREDLEND 0

AMR UL RX_LEV Upper Threshold AMRULSSHTHRED 25

AMR UL RX_LEV Lower Threshold AMRULSSLTHRED 15

AMR UL Qual. Upper Threshold AMRULQHTHRED 1

AMR UL Qual. Lower Threshold AMRULQLOWTHRED 3

AMR DL RX_LEV Upper Threshold AMRDLSSHTHRED 30

AMR DL RX_LEV Lower Threshold AMRDLSSLTHRED 20

AMR DL Qual. Upper Threshold AMRDLQHTHRED 1

AMR DL Qual. Lower Threshold AMRDLQLTHRED 3

AMR MAX Down Adj. Value Qual. Zone 0 AMRMAXSTEP0 4

AMR MAX Down Adj. Value Qual. Zone 1 AMRMAXSTEP1 2

AMR MAX Down Adj. Value Qual. Zone 2 AMRMAXSTEP2 2

AMR MAX Down Adj. PC Value by Qual. AMRQUALSTEP 4

AMR MAX Up Adj. PC Value by RX_LEV AMRMAXVALADJRX 16

AMR MAX Up Adj. PC Value by Qual. AMRMAXADJPCVAL 8

AMR UL Qual. Bad Trig Threshold AMRULQUALBADTRIG 4

AMR UL Qual. Bad UpLEVDiff AMRULQUALBADUPLEV 5

AMR DL Qual Bad Trig Threshold AMRDLQUALBADTRIG 4

AMR DL Qual Bad UpLEVDiff AMRDLQUALBADUPLEV 5

AMR BTS PC Class AMRBTSPWRNUM 16

PC Interval PCADJPERIOD 3

UL RX_LEV Upper Threshold ULSSHIGHTHRED 25

UL RX_LEV Lower Threshold ULSSLOWTHRED 15

UL Qual. Upper Threshold ULQHIGHTHRED 1

UL Qual. Lower Threshold ULQLOWTHRED 3

DL RX_LEV Upper Threshold DLSSHIGHTHRED 30

DL RX_LEV Lower Threshold DLSSLOWTHRED 20

DL Qual. Upper Threshold DLQHIGHTHRED 1

DL Qual. Lower Threshold DLQLOWTHRED 3

C2
Faisal Tasleem: PC-II is available for whole South network, except Karachi BSCs
Page 2: Template

Parameter Name Parameter Name in CME Proposed Value

Power Control Switch PWRCTRLSW PWR2

Filter Length for UL RX_LEV ULLEVFILTLEN 4

Filter Length for DL RX_LEV DLLEVFILTLEN 4

Filter Length for UL Qual. ULQUAFILTLEN 4

Filter Length for DL Qual. DLQUAFILTLEN 4

MR. Compensation Allowed MRCOMPREG Yes

UL MR. Number Predicted ULPREDLEND 0

DL MR. Number Predicted DLPREDLEND 0

MAX Down Adj.Value Qual.Zone 0 MAXSTEP0 4

MAX Down Adj.Value Qual.Zone 1 MAXSTEP1 2

MAX Down Adj.Value Qual.Zone 2 MAXSTEP2 2

MAX Down Adj. PC Value by Qual. QUALSTEP 4

MAX Up Adj. PC Value by RX_LEV MAXVALADJRX 16

MAX Up Adj. PC Value by Qual. MAXADJPCVAL 8

UL Qual. Bad Trig Threshold ULQUALBADTRIG 4

UL Qual. Bad UpLEVDiff ULQUALBADUPLEV 5

DL Qual. Bad Trig Threshold DLQUALBADTRIG 4

DL Qual. Bad UpLEVDiff DLQUALBADUPLEV 5

BTS PC Class BTSPWRNUM 16

AMR PC Interval AMRPCADJPERIOD 3

AMR Filter Length for UL RX_LEV AMRULLEVFTLEN 4

AMR Filter Length for DL RX_LEV AMRDLLEVFTLEN 4

AMR Filter Length for UL Qual AMRULQUAFTLEN 4

AMR Filter Length for DL Qual. AMRDLQUAFTLEN 4

AMR MR. Compensation Allowed AMRMRCOMPREG YES

AMR UL MR. Number Predicted AMRULPREDLEND 0

AMR DL MR. Number Predicted AMRDLPREDLEND 0

AMR UL RX_LEV Upper Threshold AMRULSSHTHRED 25

AMR UL RX_LEV Lower Threshold AMRULSSLTHRED 15

AMR UL Qual. Upper Threshold AMRULQHTHRED 1

AMR UL Qual. Lower Threshold AMRULQLOWTHRED 3

AMR DL RX_LEV Upper Threshold AMRDLSSHTHRED 30

AMR DL RX_LEV Lower Threshold AMRDLSSLTHRED 20

AMR DL Qual. Upper Threshold AMRDLQHTHRED 1

AMR DL Qual. Lower Threshold AMRDLQLTHRED 3

AMR MAX Down Adj. Value Qual. Zone 0 AMRMAXSTEP0 4

AMR MAX Down Adj. Value Qual. Zone 1 AMRMAXSTEP1 2

AMR MAX Down Adj. Value Qual. Zone 2 AMRMAXSTEP2 2

AMR MAX Down Adj. PC Value by Qual. AMRQUALSTEP 4

AMR MAX Up Adj. PC Value by RX_LEV AMRMAXVALADJRX 16

AMR MAX Up Adj. PC Value by Qual. AMRMAXADJPCVAL 8

AMR UL Qual. Bad Trig Threshold AMRULQUALBADTRIG 4

AMR UL Qual. Bad UpLEVDiff AMRULQUALBADUPLEV 5

AMR DL Qual Bad Trig Threshold AMRDLQUALBADTRIG 4

AMR DL Qual Bad UpLEVDiff AMRDLQUALBADUPLEV 5

AMR BTS PC Class AMRBTSPWRNUM 16

PC Interval PCADJPERIOD 3

C2
Faisal Tasleem: PC-II is available for whole South network, except Karachi BSCs
Page 3: Template

UL RX_LEV Upper Threshold ULSSHIGHTHRED 25

UL RX_LEV Lower Threshold ULSSLOWTHRED 15

UL Qual. Upper Threshold ULQHIGHTHRED 1

UL Qual. Lower Threshold ULQLOWTHRED 3

DL RX_LEV Upper Threshold DLSSHIGHTHRED 30

DL RX_LEV Lower Threshold DLSSLOWTHRED 20

DL Qual. Upper Threshold DLQHIGHTHRED 1

DL Qual. Lower Threshold DLQLOWTHRED 3

Page 4: Template

Parameter Name Parameter Name in CME Proposed Value

Power Control Switch PWRCTRLSW PWR3

HwIII Number of lost MRs allowed MRMissNumber 5

HwIII Up Link Power Control Adjust Period PwrCtrlULAdjPeriod 3

HwIII Down Link Power Control Adjust Period PwrCtrlDLAdjPeriod 2

HwIII Signal Channel Discard MR Number SdMrCutNum 1

HwIII Traffic Channel Discard MR Number TchMrCutNum 3

HwIII DL RexLev Exponent Filter Length DLRexLevExponentFilterLen 3

HwIII DL Rex Qual. Exponent Filter Length DLRexQualExponentFilterLen 3

HwIII DL RexLev Slide Window DLRexLevSlideWindow 1

HwIII DL Rex Qual. Slide Window DLRexQualSlideWindow 1

HwIII DL RexLev Adjust Factor DLRexLevAdjustFactor 4

HwIII DL Rex Qual. Adjust Factor DLRexQualAdjustFactor 4

HwIII DL RexLev Upper Threshold DLRexLevHighThred 30

HwIII DL RexLev Lower Threshold DLRexLevLowthred 20

HwIII DL FS Rex Qual. Upper Threshold(dB) DLFSRexQualHighThred 18

HwIII DL FS Rex Qual. Lower Threshold(dB) DLFSRexQualLowThred 18

HwIII DL HS Rex Qual. Upper Threshold(dB) DLHSRexQualHighThred 20

HwIII DL HS Rex Qual. Lower Threshold(dB) DLHSRexQualLowThred 20

HwIII DL AFS Rex Qual.Upper Threshold(dB) DLAFSRexQualHighThred 16

HwIII DL AFS Rex Qual.Lower Threshold(dB) DLAFSRexQualLowThred 16

HwIII DL AHS Rex Qual.Upper Threshold(dB) DLAHSRexQualHighThred 18

HwIII DL AHS Rex Qual. Lower Threshold(dB) DLAHSRexQualLowThred 18

HwIII DL MAX DownStep(dB) DLMAXDownStep 6

HwIII DL MAX UpStep (dB) DLMAXUpStep 8

HwIII UL RexLev Exponent Filter Length ULRexLevExponentFilterLen 3

HwIII UL Rex Qual.Exponent Filter Length ULRexQualExponentFilterLen 3

HwIII UL RexLev Slide Window ULRexLevSlideWindow 1

HwIII UL Rex Qual. Slide Window ULRexQualSlideWindow 1

HwIII UL RexLev Adjust Factor ULRexLevAdjustFactor 4

HwIII UL Rex Qual.Adjust Factor ULRexQualAdjustFactor 4

HwIII UL RexLev Upper Threshold ULRexLevHighThred 25

HwIII UL RexLev Lower Threshold ULRexLevLowThred 15

HwIII UL FS Rex Qual. Upper Threshold(dB) ULFSRexQualHighThred 18

HwIII UL FS Rex Qual. Lower Threshold(dB) ULFSRexQualLowThred 18

HwIII UL HS Rex Qual.Upper Threshold(dB) ULHSRexQualHighThred 20

HwIII UL HS Rex Qual.Lower Threshold(dB) ULHSRexQualLowThred 20

HwIII UL AFS Rex Qual.Upper Threshold(dB) ULAFSRexQualHighThred 16

HwIII UL AFS Rex Qual.Lower Threshold(dB) ULAFSRexQualLowThred 16

HwIII UL AHS Rex Qual.Upper Threshold(dB) ULAHSRexQualHighThred 18

HwIII UL AHS Rex Qual.Lower Threshold(dB) ULAHSRexQualLowThred 18

HwIII UL MAX DownStep(dB) ULMAXDownStep 6

HwIII UL MAX UpStep(dB) ULMAXUpStep 8

III Power Control Optimized Enable III Power Control Optimized Enable YES

III UL Filter Adjust Factor III UL Filter Adjust Factor 3

III DL Filter Adjust Factor III DL Filter Adjust Factor 3

III UL RexLev Protect Factor III UL RexLev Protect Factor 10

III UL RexQual Protect Factor III UL RexQual Protect Factor 75

C2
Faisal Tasleem: PCIII is available only for Karachi BSCs in South
Page 5: Template

III DL RexLev Protect Factor III DL RexLev Protect Factor 10

III DL RexQual Protect Factor III DL RexQual Protect Factor 75

Page 6: Template

Parameter Name Parameter Name in CME

Current HO Control Algorithm HOCTRLSWITCH

No Dl Mr.Ul Qual HO Limit NODLMRHOQUALLIMIT

Edge HO UL RX_LEV Threshold ULEDGETHRES

Edge HO DL RX_LEV Threshold DLEDGETHRES

Intracell F-H HO Stat Time INFHHOSTAT

Intracell F-H HO Last Time INFHHOLAST

F2H HO Threshold INHOF2HTH

H2F HO Threshold INHOH2FTH

Inter-layer HO Threshold HOTHRES

Inter-layer HO Hysteresis LEVHOHYST

Filter Length for Ncell RX_LEV NCELLFLTLEN

Penalty Time after BQ HO TIMEBQPUNISH

Penalty Time after TA HO TIMETAPUNISH

UtoO HO Received Level Threshold UTOORECTH

DL Qual. Threshold DLQUALIMIT

UL Qual. Threshold ULQUALIMIT

MR.Preprocessing BTSMESRPTPREPROC

Intracell HO Allowed INTRACELLHOEN

Concentric Circles HO Allowed CONHOEN

Min UL Level on Candidate Cell HOCDCMINUPPWR

Min DL Level on Candidate Cell HOCDCMINDWPWR

Co-BSC/MSC Adj COBSCMSCADJEN

Assign Optimum level threshold OPTILEVTHRES

DL Qual. Limit for AMR FR DLQUALIMITAMRFR

UL Qual. Limit for AMR FR ULQUALIMITAMRFR

DL Qual. Limit for AMR HR DLQUALIMITAMRHR

UL Qual. Limit for AMR HR ULQUALIMITAMRHR

TA Threshold TALIMIT

Filter Parameter A1 FLTPARAA1

Filter Parameter A2 FLTPARAA2

Filter Parameter A3 FLTPARAA3

Filter Parameter A4 FLTPARAA4

Filter Parameter A5 FLTPARAA5

Filter Parameter A6 FLTPARAA6

Filter Parameter A7 FLTPARAA7

Filter Parameter A8 FLTPARAA8

Filter Parameter B FLTPARAB

No Dl Mr.HO Allowed NODLMRHOEN

Cons.No Dl Mr.HO Allowed Limit NODLMRHOALLOWLIMIT

Min Interval for TCH Hos TCHHOMININTV

Min Interval for SDCCH Hos SDHOMININTV

Min Interval for Consecutive HOs CONTHOMININTV

Min Interval for Emerg. HO NEWURGHOMININTV

Page 7: Template

Inter-BSC SDCCH HO ALLowed INRBSCSDHOEN

Penalty Allowed PENALTYEN

Min Power Level For Directed Retry MINPWRLEVDIRTRY

SDCCH HO Allowed SIGCHANHOEN

Intracell F-H HO Allowed INTRACELLFHHOEN

Load Handover Support LOADHOEN

MS Fast Moving HO Allowed QCKMVHOEN

Rx_Level_Drop HO Allowed RXQCKFALLHOEN

PBGT HO Allowed PBGTHOEN

Level HO Allowed LEVHOEN

Edge HO Allowed/Fringe HO allowed FRINGEHOEN

BQ HO Allowed BQHOEN

TA HO Allowed TAHOEN

Interference HO Allowed INTERFHOEN

Quick Handover Enable QUICKHOEN

Concentric Circles ATCB HO Allowed/ATCB HO switch ATCBHOEN

Inter-RAT Out BSC Handover Enable INTERRATOUTBSCHOEN

Inter-RAT In BSC Handover Enable INTERRATINBSCHOEN

Allow Incoming BSC Handover at Iur-g INTERRATIURGINBSCHOEN

Inter-RAT Cell Reselection Enable INTERRATCELLRESELEN

Handover Algorithm I Edge HO Watch Time EDGESTAT1

Handover Algorithm I Edge HO Valid Time EDGELAST1

Allowed MR Number Lost MRMISSCOUNT

Filter Length for TCH Level DATASTRFLTLEN

Filter Length for TCH Qual DATAQUAFLTLEN

Filter Length for SDCCH Level SIGSTRFLTLEN

Filter Length for SDCCH Qual SIGQUAFLTLEN

Filter Length for TA TAFLTLEN

Penalty Level after HO Fail FAILSIGSTRPUNISH

Penalty Level after BQ HO SSBQPUNISH

Penalty Level after TA HO SSTAPUNISH

Penalty Time after AMR TCHF-H HO Fail TIMEAMRFHPUNISH

RscPenaltyTimer RSCPENALTYTIMER

UmPenaltyTimer UMPENALTYTIMER

CfgPenaltyTimer PENALTYTIMER

Filter Length for SDCCH MEAN_BEP MBSIGNLEN

Filter Length for TCH MEAN_BEP MBTRAFFLEN

Filter Length for SDCCH CV_BEP CBSIGNLEN

Filter Length for TCH CV_BEP CBTRAFFLEN

Filter Length for SDCCH REP_QUANT RQSIGNLEN

Filter Length for TCH REP_QUANT RQTRAFFLEN

Filter Length for SDCCH NBR_RCVD_BLOCK NRBSDCCHFFLEN

Filter Length for TCH NBR_RCVD_BLOCK NRBTCHFFLEN

MS Power Prediction after HO PWRPREDICTEN

UL to OL HO Allowed ULTOOLHOALLOW

Page 8: Template

OL to UL HO Allowed OLTOULHOALLOW

RX_LEV for UO HO Allowed RECLEVUOHOALLOW

RX_QUAL for UO HO Allowed RECQUALUOHOALLOW

TA for UO HO Allowed TAFORUOHOALLOW

Enhanced Concentric Allowed ENIUO

UtoO Traffic HO Allowed UTOOTRAFHOALLOW

Assign Optimum Layer OPTILAYER

TA Pref. of Imme-Assign Allowed IMMASSTAALLOW

Pref. Subcell in HO of Intra-BSC HOALGOPERMLAY

OtoU HO Received Level Threshold OTOURECEIVETH

TA Threshold of Assignment Pref. OPTITATHRES

TA Threshold of Imme-Assign Pref. IMMASSTATHRES

Incoming-to-BSC HO Optimum Layer ACCESSOPTILAY

Edge HO UL RX_LEV Threshold ULEDGETHRES

Edge HO DL RX_LEV Threshold DLEDGETHRES

Page 9: Template

Proposed Value

Urban Rural

HOALGORITHM1 HOALGORITHM1

60 60

8 8

8 8

5 5

4 4

30 30

10 10

40 40

1 1

6 6

15 15

30 30

30 30

60 70

60 70

BSC_Preprocessing BSC_Preprocessing

NO NO

YES YES

0 (For KHI & Hyderabad) for rest make it 10

0 (For KHI & Hyderabad) for rest make it 15

NO NO

20

60 70

60 70

60 70

60 70

255 255

10 10

10 10

10 10

10 10

10 10

10 10

10 10

10 10

0 0

NO NO

8 8

2 2

2 2

4 4

4 4

C3
Faisal Tasleem: HW HO-I settings for Karachi and Hyderabad City only
D3
Faisal Tasleem: HW HO-I settings for Karachi and Hyderabad City only
Page 10: Template

NO NO

YES YES

16 16

NO NO

YES YES

NO NO

NO NO

NO NO

YES YES

YES YES

YES YES

YES YES

YES YES

YES YES

NO NO

NO NO

NO NO

NO NO

NO NO

NO NO

4 4

3 3

4 4

4 4

4 4

2 2

2 2

4 4

30 30

63 63

63 63

30 30

5 5

10 10

255 255

2 2

6 6

2 2

6 6

2 2

6 6

2 2

6 6

No No

YES YES

Page 11: Template

YES YES

YES YES

No No

No No

YES YES

NO NO

System Optimization System Optimization

No No

System Optimization System Optimization

20 20

63 63

0 0

Underlaid subcell Underlaid subcell

8 8

8 8

Page 12: Template

COMMENTS

IF CELL IUO TYPE="CONCENTRC"

IF CELL IUO TYPE="CONCENTRC"

IF CELL IUO TYPE="CONCENTRC"

Page 13: Template

IF CELL IUO TYPE="CONCENTRC"

IF CELL IUO TYPE="CONCENTRC"

Page 14: Template

IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"IF CELL IUO TYPE="CONCENTRC"

Page 15: Template

Parameter Name Parameter Name in CME

HOCTRLSWITCH Current HO Control Algorithm

Edge HO UL RX_LEV Threshold ULEDGETHRES

Edge HO DL RX_LEV Threshold DLEDGETHRES

F2H HO Threshold INHOF2HTH

Inter-layer HO Threshold HOTHRES

Inter-layer HO Hysteresis LEVHOHYST

Filter Length for SDCCH Level SIGSTRFLTLEN

Filter Length for Ncell RX_LEV NCELLFLTLEN

Penalty Level after HO Fail FAILSIGSTRPUNISH

RscPenaltyTimer RSCPENALTYTIMER

UmPenaltyTimer UMPENALTYTIMER

CfgPenaltyTimer PENALTYTIMER

DL Qual. Threshold DLQUALIMIT

UL Qual. Threshold ULQUALIMIT

Intracell HO Allowed INTRACELLHOEN

Min UP Power on HO Candidate Cell HOCDCMINUPPWR

Min DL Power on HO Candidate Cell HOCDCMINDWPWR

Co-BSC/MSC Adj COBSCMSCADJEN

RX_LEV for UO HO Allowed RECLEVUOHOALLOW

RX_QUAL for UO HO Allowed RECQUALUOHOALLOW

TA for UO HO Allowed TAFORUOHOALLOW

Enhanced Concentric Allowed ENIUO

UtoO Traffic HO Allowed UTOOTRAFHOALLOW

Assign Optimum Layer OPTILAYER

Pref. Subcell in HO of Intra-BSC HOALGOPERMLAY

Assign Optimum level threshold OPTILEVTHRES

DL Qual. Limit for AMR FR DLQUALIMITAMRFR

UL Qual. Limit for AMR FR ULQUALIMITAMRFR

DL Qual. Limit for AMR HR DLQUALIMITAMRHR

UL Qual. Limit for AMR HR ULQUALIMITAMRHR

TA Threshold TALIMIT

Filter Parameter A1 FLTPARAA1

Filter Parameter A2 FLTPARAA2

Filter Parameter A3 FLTPARAA3

Filter Parameter A4 FLTPARAA4

Filter Parameter A5 FLTPARAA5

Filter Parameter A6 FLTPARAA6

Filter Parameter A7 FLTPARAA7

Filter Parameter A8 FLTPARAA8

Filter Parameter B FLTPARAB

No Dl Mr.HO Allowed NODLMRHOEN

No Dl Mr.Ul Qual HO Limit NODLMRHOQUALLIMIT

Cons.No Dl Mr.HO Allowed Limit NODLMRHOALLOWLIMIT

Min Interval for TCH Hos TCHHOMININTV

Min Interval for SDCCH Hos SDHOMININTV

Min Interval for Consecutive HOs CONTHOMININTV

Page 16: Template

Min Interval for Emerg. HO NEWURGHOMININTV

Inter-BSC SDCCH HO ALLowed INRBSCSDHOEN

Penalty Allowed PENALTYEN

MR.Preprocessing BTSMESRPTPREPROC

Min Power Level For Directed Retry MINPWRLEVDIRTRY

SDCCH HO Allowed SIGCHANHOEN

Intracell F-H HO Allowed INTRACELLFHHOEN

Load Handover Support LOADHOEN

MS Fast Moving HO Allowed QCKMVHOEN

Rx_Level_Drop HO Allowed RXQCKFALLHOEN

PBGT HO Allowed PBGTHOEN

Level HO Allowed LEVHOEN

Edge HO Allowed/Fringe HO allowed FRINGEHOEN

BQ HO Allowed BQHOEN

TA HO Allowed TAHOEN

Concentric Circles HO Allowed CONHOEN

Interference HO Allowed INTERFHOEN

Intracell F-H HO Stat Time INFHHOSTAT

Intracell F-H HO Last Time INFHHOLAST

H2F HO Threshold INHOH2FTH

Quick Handover Enable QUICKHOEN

Concentric Circles ATCB HO Allowed/ATCB HO switch ATCBHOEN

Handover Algorithm I Edge HO Watch Time EDGESTAT1

Handover Algorithm I Edge HO Valid Time EDGELAST1

Allowed MR Number Lost MRMISSCOUNT

Filter Length for TCH Level DATASTRFLTLEN

Filter Length for TCH Qual DATAQUAFLTLEN

Filter Length for SDCCH Qual SIGQUAFLTLEN

Filter Length for TA TAFLTLEN

Penalty Level after BQ HO SSBQPUNISH

Penalty Time after BQ HO TIMEBQPUNISH

Penalty Level after TA HO SSTAPUNISH

Penalty Time after TA HO TIMETAPUNISH

Penalty Time after AMR TCHF-H HO Fail TIMEAMRFHPUNISH

Filter Length for SDCCH MEAN_BEP MBSIGNLEN

Filter Length for TCH MEAN_BEP MBTRAFFLEN

Filter Length for SDCCH CV_BEP CBSIGNLEN

Filter Length for TCH CV_BEP CBTRAFFLEN

Filter Length for SDCCH REP_QUANT RQSIGNLEN

Filter Length for TCH REP_QUANT RQTRAFFLEN

Filter Length for SDCCH NBR_RCVD_BLOCK NRBSDCCHFFLEN

Filter Length for TCH NBR_RCVD_BLOCK NRBTCHFFLEN

MS Power Prediction after HO PWRPREDICTEN

UL to OL HO Allowed ULTOOLHOALLOW

OL to UL HO Allowed OLTOULHOALLOW

TA Pref. of Imme-Assign Allowed IMMASSTAALLOW

OtoU HO Received Level Threshold OTOURECEIVETH

UtoO HO Received Level Threshold UTOORECTH

Page 17: Template

TA Threshold of Assignment Pref. OPTITATHRES

TA Threshold of Imme-Assign Pref. IMMASSTATHRES

Incoming-to-BSC HO Optimum Layer ACCESSOPTILAY

Edge HO UL RX_LEV Threshold ULEDGETHRES

Edge HO DL RX_LEV Threshold DLEDGETHRES

Page 18: Template

Proposed Value

Urban Rural

HOALGORITHM1 HOALGORITHM1

8 8

8 8

30 30

40 40

1 1

2 2

6 6

30 30

5 5

10 10

255 255

60 70

60 70

NO NO

0 (For KHI & Hyderabad) for rest make it 10

0 (For KHI & Hyderabad) for rest make it 15

NO NO

YES YES

No No

No No

YES YES

No No

System Optimization System Optimization

System Optimization System Optimization

20 20

60 70

60 70

60 70

60 70

10 10

10 10

10 10

10 10

10 10

10 10

10 10

10 10

0 0

NO NO

60 60

8 8

2 2

2 2

4 4

C3
Faisal Tasleem: HW HO-I settings for Karachi and Hyderabad City only
D3
Faisal Tasleem: HW HO-I settings for Karachi and Hyderabad City only
Page 19: Template

4 4

NO NO

YES YES

BSC_Preprocessing BSC_Preprocessing

16 16

NO NO

YES YES

NO NO

NO NO

NO NO

YES YES

YES YES

YES YES

YES YES

YES YES

YES YES

YES YES

5 5

4 4

10 10

NO NO

NO NO

4 4

3 3

4 4

4 4

4 4

2 2

4 4

63 63

15 15

63 63

30 30

30 30

2 2

6 6

2 2

6 6

2 2

6 6

2 2

6 6

No No

YES YES

YES YES

No No

20 20

30 30

Page 20: Template

63 63

0 0

Underlaid subcell Underlaid subcell

8 8

8 8

Page 21: Template

COMMENTS

IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"

Page 22: Template

IF CELL TYPE="CONCENTRC"

IF CELL TYPE="CONCENTRC"

IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"

Page 23: Template

IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"IF CELL TYPE="CONCENTRC"

Page 24: Template

Parameter Name Parameter Name in CME

CS RACH Min. Access Level RACHACCLEV

Cell Reselect Hysteresis Parameter CRH

Radio Link Timeout(SACCH period(480ms)) RLT

AFR Radio Link Timeout AFRDSBLCNT

AHR Radio Link Timeout AHRDSBLCNT

T3212 T3212

Paging Times PAGTIMES

AFR SACCH Multi-Frames AFRSAMULFRM

CCCH Blocks Reserved for AGCH BSAGBLKSRES

NCC Permitted NCCPERMIT

Interfere Band Stat Algorithm Type INTERBANDSTATALGO

TCH Rate Adjust Allow TCHAJFLAG

Speech Version SPEECHVERSION

AMR ACS[F] ACTCDSETF

Layer of The Cell LAYER

DL PC Allowed DNPCEN

Interference Calculation Period INTERPERIOD

UL PC Allowed UPPCEN

Tx-Integer TX

Random Access Error Threshold RANERRTHRED

SACCH Multi-Frames SAMULFRM

RACH Busy Threshold RACHBUSYTHRED

AHR SACCH Multi-Frames AHRSAMULFRM

Assignment Cell Load Judge Enable ASSLOADJUDGEEN

MS MAX Retrans MSMAXRETRAN

Additional Reselect Parameter Indication ACS

Wait for REL Indication AMR FR WAITFORRELINDAMRFR

T3109 for AMR HR WAITFORRELINDAMRHR

FR Use Downlink DTX FRDLDTX

FR Uplink DTX FRULDTX

HR Use Downlink DTX HRDLDTX

HR Uplink DTX HRULDTX

TCH Immediate Assignment IMMASSEN

Directed Retry DIRECTRYEN

SDCCH Dynamic Allocation Allowed SDDYN

Multi-Frames in a Cycle on the Paging CH BSPAMFRAMS

T200 SDCCH T200SDCCH

T200 FACCH/F T200FACCHF

T200 FACCH/H T200FACCHH

T200 SACCH TCH SAPI0 T200SACCT0

T200 SACCH TCH SAPI3 T200SACCH3

T200 SACCH SDCCH T200SACCHS

T200 SDCCH SAPI3 T200SDCCH3

Use LAPDm N200 N200PARASWITCH

Use IMM ASS Retransmit Parameter IMMASSRESENDEN

Max Delay of IMM ASS Retransmit IMMASSMAXDELAYTIME

Max Transmit Times of IMM ASS IMMASSMAXSENDNUM

Page 25: Template

Directed Retry Load Access Threshold DTLOADTHRED

Immediate Assignment Optimized IMMASSCBB

Short Message Uplink Disabled UPSENDSMDIS

Short Message Downlink Disabled DNSENDSMDIS

Allow Reassign REASSEN

Idle SDCCH Threshold N1 IDLESDTHRES

Cell SDCCH Channel Maximum CELLMAXSD

TCH Minimum Recovery Time MINRESTIMETCH

Interf. Priority Allowed INTERFPRIALLOW

Active CH Interf. Meas.Allowed CHANINTERMESALLOW

Allocation TRX Priority Allowed TRXPRIALLOW

AMR TCH/H Prior Allowed AMRTCHHPRIORALLOW

Interference Band Threshold 0 INTERFTHRES0

Interference Band Threshold 1 INTERFTHRES1

Interference Band Threshold 2 INTERFTHRES2

Interference Band Threshold 3 INTERFTHRES3

Interference Band Threshold 4 INTERFTHRES4

Interference Band Threshold 5 INTERFTHRES5

MS_TXPWR_MAX_CCH FMSMAXOPCC

Chain Neighbor Cell ISCHAINNCELL

Adjacent Cell Inter-layer HO Hysteresis INTELEVHOHYST

Drop Optimize Err Ind[T200 timeout] DROPCTRLERRINDT200

Drop Optimize Err Ind[unsolicited DM response] DROPCTRLERRINDDMRSP

Drop Optimize Err Ind[sequence error] DROPCTRLERRINDSEQERR

Drop Optimize Conn Fail[radio link fail] DROPCTRLCONNFAILRLFAIL

Drop Optimize Conn Fail[HO access fail] DROPCTRLCONNFAILHOACCFAIL

Drop Optimize Conn Fail[OM intervention] DROPCTRLCONNFAILOM

Drop Optimize Conn Fail[resource not available]DROPCTRLCONNFAILRRNOTAVL

Drop Optimize Conn Fail[other] DROPCTRLCONNFAILOTHER

Drop Optimize Release Indication DROPCTRLRELIND

Drop Optimize ABIS Link Failure DROPCTRLABISCONNFAIL

Drop Optimize Equipment Failure DROPCTRLEQUIPFAIL

Drop Optimize Forced Handover Failure DROPCTRLFORCHOFAIL

Drop Optimize No MR for Long Time DROPCTRLNOMR

Drop Optimize Resource Check DROPCTRLRESCHK

Drop Optimize Into-BSC Handover Timeout DROPCTRLINBSCHO

Drop Optimize Out-BSC Handover Timeout DROPCTRLOUTBSCHOT8

Drop Optimize Intra-BSC Handover Timeout DROPCTRLINTRABSCOUTHO

Drop Optimize Intra-Cell Handover Timeout DROPCTRLINTRACELLHO

CRO CRO

MAX TA MAXTA

RX LEV access min RXMIN

Cell Priority CMEPRIOR

Encryption Algorithm ENCRY

Page 26: Template

Proposed Value

-105

6

32

32

32

60

2

32

0

1111111

IBAN-I

YES

1111010

00110011

3 for MACRO & 2 for MICRO

YES

20

YES

TX_32

180

32

16

32

DISABLE

4_Times

COMPUL0

34000ms

26000ms

Yes

Shall Use

Yes

Shall Use

No

Yes

Yes

2 Multiframe Period

60

50

50

150

200

60

60

OFF

NO

4

2

Page 27: Template

85

No

No

No

Yes

2

80

60

Yes

Yes

Yes

ON

110

105

98

92

87

85

5 for 900BCCH cells & 0 for 1800 BCCH cells

No

67

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

0

63

8

PRIOR-1

11000000

Page 28: Template

Parameter Name Parameter Name in CME

Radio Link Timeout(SACCH period(480ms)) RLT

AFR Radio Link Timeout AFRDSBLCNT

AHR Radio Link Timeout AHRDSBLCNT

T3212 T3212

SACCH Multi-Frames SAMULFRM

Paging Times PAGTIMES

AFR SACCH Multi-Frames AFRSAMULFRM

CCCH Blocks Reserved for AGCH BSAGBLKSRES

SDCCH Dynamic Allocation Allowed SDDYN

Interfere Band Stat Algorithm Type INTERBANDSTATALGO

Speech Version SPEECHVERSION

AMR ACS[F] ACTCDSETF

Layer of The Cell LAYER

DL PC Allowed DNPCEN

CS RACH Min. Access Level RACHACCLEV

Cell Reselect Hysteresis Parameters CRH

Interference Calculation Period INTERPERIOD

UL PC Allowed UPPCEN

TX-integer TX

Random Access Error Threshold RANERRTHRED

RACH Busy Threshold RACHBUSYTHRED

AHR SACCH Multi-Frames AHRSAMULFRM

Assignment Cell Load Judge Enable ASSLOADJUDGEEN

MS MAX Retrans MSMAXRETRAN

Additional Reselect Parameter Indication ACS

NCC Permitted NCCPERMIT

TCH Rate Adjust Allow TCHAJFLAG

DL DTX DLDTX

UL DTX ULDTX

TCH Immediate Assignment IMMASSEN

Directed Retry DIRECTRYEN

BS-PA-MFRAMS #N/A

T200 SDCCH(5ms) T200SDCCH

T200 FACCH/F(5ms) T200FACCHF

T200 FACCH/H(5ms) T200FACCHH

T200 SACCH TCH SAPI0(10ms) T200SACCT0

T200 SACCH TCH SAPI3(10ms) T200SACCH3

T200 SACCH SDCCH(10ms) T200SACCHS

T200 SDCCH SAPI3(5ms) T200SDCCH3

Use LAPDm N200 N200PARASWITCH

Use IMM ASS Retransmit Parameter IMMASSRESENDEN

Max Delay of IMM ASS Retransmit IMMASSMAXDELAYTIME

Max Transmit Times of IMM ASS IMMASSMAXSENDNUM

Directed Retry Load Access Threshold DTLOADTHRED

Immediate Assignment Opt IMMASSCBB

Short Message Uplink Disabled UPSENDSMDIS

Short Message Downlink Disabled DNSENDSMDIS

Page 29: Template

Allow Reassign REASSEN

Idle SDCCH Threshold N1 IDLESDTHRES

Cell SDCCH Channel Maximum CELLMAXSD

TCH Minimum Recovery Time MINRESTIMETCH

Interf. Priority Allowed INTERFPRIALLOW

Active CH Interf. Meas.Allowed CHANINTERMESALLOW

Allocation TRX Priority Allowed TRXPRIALLOW

AMR TCH/H Prior Allowed AMRTCHHPRIORALLOW

Interf. Band Threshold 0 (-dBm) INTERFTHRES0

Interf. Band Threshold 1 (-dBm) INTERFTHRES1

Interf. Band Threshold 2 (-dBm) INTERFTHRES2

Interf. Band Threshold 3 (-dBm) INTERFTHRES3

Interf. Band Threshold 4 (-dBm) INTERFTHRES4

Interf. Band Threshold 5 (-dBm) INTERFTHRES5

MS_TXPWR_MAX_CCH FMSMAXOPCC

Chain Neighbor Cell ISCHAINNCELL

Adjacent Cell Inter-layer HO Hysteresis INTELEVHOHYST

Drop Optimize Err Ind[T200 timeout] DROPCTRLERRINDT200

Drop Optimize Err Ind[unsolicited DM response] DROPCTRLERRINDDMRSP

Drop Optimize Err Ind[sequence error] DROPCTRLERRINDSEQERR

Drop Optimize Conn Fail[radio link fail] DROPCTRLCONNFAILRLFAIL

Drop Optimize Conn Fail[HO access fail] DROPCTRLCONNFAILHOACCFAIL

Drop Optimize Conn Fail[OM intervention] DROPCTRLCONNFAILOM

Drop Optimize Conn Fail[resource not available] DROPCTRLCONNFAILRRNOTAVL

Drop Optimize Conn Fail[other] DROPCTRLCONNFAILOTHER

Drop Optimize Release Indication DROPCTRLRELIND

Drop Optimize ABIS Link Failure DROPCTRLABISCONNFAIL

Drop Optimize Equipment Failure DROPCTRLEQUIPFAIL

Drop Optimize Forced Handover Failure DROPCTRLFORCHOFAIL

Drop Optimize No MR for Long Time DROPCTRLNOMR

Drop Optimize Resource Check DROPCTRLRESCHK

Drop Optimize Into-BSC Handover Timeout DROPCTRLINBSCHO

Drop Optimize Out-BSC Handover Timeout DROPCTRLOUTBSCHOT8

Drop Optimize Intra-BSC Handover Timeout DROPCTRLINTRABSCOUTHO

Drop Optimize Intra-Cell Handover Timeout DROPCTRLINTRACELLHO

Cell Reselect Offset CRO

MAX TA MAXTA

Minum Access RXLEV RXMIN

Cell Priority CMEPRIOR

Encryption Algorithm ENCRY

Page 30: Template

Proposed Value

32

32

32

60

32

2

32

0

YES

Interference Band Measurement Algorithm I

101111

11001100

3 for MACRO & 2 for MICRO

YES

-105

6

20

YES

32

180

16

32

DISABLE

4

NO

1111111

YES

Yes

Shall Use

NO

YES

2 Multiframe Period

60

50

50

150

200

60

60

No

NO

4

2

85

No

No

No

Page 31: Template

Yes

2

80

60

Yes

Yes

Yes

Yes

110

105

98

92

87

85

5 for 900BCCH cells & 0 for 1800 BCCH cells

0

67

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

0

63

8

PRIOR-1

11000000

Page 32: Template

Parameter Name Parameter Name in CME

Inter-cell HO Hysteresis INTERCELLHYST

PBGT HO Threshold PBGTMARGIN

BQ HO Margin BQMARGIN

Adjacent Cell Inter-layer HO Hysteresis INTELEVHOHYST

Min access level offset MINOFFSET

Page 33: Template

Proposed Value(6000) Proposed Value(6900)

4 64

68 68

69 69

67 67

15 (For KHI & Hyderabad) for rest make it 0