tender documentamp or tri-amp mode, bi-amp or tri-amp, transducer high frequency dual 50 w, 8 ohm...

27
T T E E N N D D E E R R D D O O C C U U M M E E N N T T (NIT No. : RGNUL/CMW/4 Dated: 08/03/2016 VOLUME – 2 (Construction and Maintenance Wing) Rajiv Gandhi National University of Law, Punjab, Patiala ARCHITECT/ CONSULTANTS: M/s Kothari Associates Pvt. Ltd. G – 65, Connaught Circus, New Delhi 110001 011 23325040, 011 23324598, Fax: 011 23712001 SERVICE CONSULTANT M/s MAPLE CONSULTANTS New Delhi, Ph. No. 9650390211 Email: [email protected] Furnishing for 1000 Seater Auditorium with Supplying Installation Testing & Commissioning (SITC) of Audio Visual System, Stage/General Lighting &, Acoustic Treatment Works etc. at RGNUL Punjab at Patiala

Upload: others

Post on 31-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 1 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

TTEENNDDEERR DDOOCCUUMMEENNTT (NIT No. : RGNUL/CMW/4

Dated: 08/03/2016

VOLUME – 2

(Construction and Maintenance Wing) Rajiv Gandhi National University of Law, Punjab, Patiala ARCHITECT/ CONSULTANTS: M/s Kothari Associates Pvt. Ltd.

G – 65, Connaught Circus, New Delhi 110001 011 23325040, 011 23324598, Fax: 011 23712001 SERVICE CONSULTANT M/s MAPLE CONSULTANTS New Delhi, Ph. No. 9650390211 Email: [email protected]

Furnishing for 1000 Seater Auditorium with Supplying Installation Testing & Commissioning (SITC) of Audio Visual System, Stage/General

Lighting &, Acoustic Treatment Works etc. at RGNUL Punjab at Patiala

Page 2: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 2 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

RRGGNNUULL,, PPUUNNJJAABB (Construction and Maintenance Wing)

TTTEEENNNDDDEEERRR DDDOOOCCCUUUMMMEEENNNTTT

TTTEEENNNDDDEEERRR NNNOOO...

:::

RRRGGGNNNUUULLL///CCCMMMWWW/// 000444

NAME OF WORK ::: Furnishing for 1000 Seater Auditorium with SITC of Audio Visual System, Stage / General Lighting &, Acoustic Treatment Works etc. at RGNUL Punjab at Patiala

TIME LIMIT ::: 4 MONTHS

EARNEST MONEY

:::

Rs 100000.00 LAC

LAST DATE AND TIME OF RECEIPT OF TENDERS

::: 31/03/2016 (UPTO 11:00 A.M.)

DATE AND TIME OF OPENING OF TENDERS ( TECHNICAL BID)

::: 01/04/2016 (AT 11:30 A.M.)

COST OF TENDER ::: Rs. 10000/-

PROCESSING FEE

::: RS. 5750/-

DATE AND TIME OF OPENING OF TENDERS ( FINANCIAL BID)

::: 05/04/2016 (AT 11:00 A.M.)

Page 3: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 3 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

******CCCOOONNNTTTEEENNNTTTSSS****** 59-8259-82

Page 4: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 4 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

(BILL OF QUANTITIES)

Page 5: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 5 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

NOTES:‐

1. ApprovedEquivalents,wherevermentionedaresubjecttotheapprovalbyRGNULbeforeexecution.

2. Successful bidder will justify his quoted rates dulysupportedwith thePrice list/MRPof thecompany forvariousmaterialsandlabourcomponent.

3. The bidder shall give the comprehensive onsitewarranty of all the equipments for the period of 3years.

4. Scaffolding shallbe suppliedby theUniversity freeofcost. However details of scaffolding required withdetails shall be submitted by the bidders with fulljustificationalongwithperiod forwhichscaffolding isrequired.PeriodofscaffoldingshallbeapprovedbytheEngineer‐in‐charge.Incasethebidderfailstocompletetheworkwithintheapprovedschedulethan,thebidderhas to make his own arrangement or same shall beprovidedforaspecificperiodforwhichamountshallbecalculated by the Engineer In Charge for deductionfrom the bill. No extension in time limit shall beprovided on this account. The bidders should quotetheirrateskeepinginmindthat,thescaffoldingshallbeprovided by the RGNUL. It is further added that,scaffoldingforminorworkswillnotbemadeavailablespecially, for suchworks arrangements like Ladder&Staging(Ghori)shallbemadebythebidderhimself.Itishowevermadeclearthat,thebidderwilltakealltheprecautions not to damage/theft of the scaffolding.Anyhow, if any damage is done, the same shall berestored to its original shape& size by the executingagency.

Page 6: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 6 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

Sr.No. Audio Visual System For Auditorium (Size 37407mm x

31890mm)-1000 Pax Qty. Unit. Approved

Make Rate Amount

ASoundReinforcementSystem‐MainSystem‐ Left&Right

1 SITC of Leftnstallation line array - Configuration 3-way, bi-amp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200 W, 16 ohm 8" woofers, 2" voice coils, neodymium magnet assemblies, weather resistant cone,Frequency Response 80 Hz - 20 kHz,Nominal Impedance,HF: 16 ohms ,LF bi-amp mode: 8 ohms, LF tri-amp mode: 16 ohms (x2),Sensitivity (1 W @ 1 m) HF: 106 dB LF: 97 dB,Continuous Power Capacity HF: 100 W ,LF bi-amp mode: 400 W, LF tri-amp mode: 200 W (x2),Recommended Power HF: 200 W, LF bi-amp mode: 800 W, LF tri-amp mode: 400 W (x2),Maximum Output (dB SPL at 1 m) Continuous / Peak,HF: 126 dB / 132 dB , LF: 122 dB / 128 dB ,Nominal Coverage Horizontal 140 degrees ,Vertical: dependent on number of elements used.

8 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

2 SITC of Right Installation line array - Configuration 3-way, bi-amp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200 W, 16 ohm 8" woofers, 2" voice coils, neodymium magnet assemblies, weather resistant cone,Frequency Response 80 Hz - 20 kHz,Nominal Impedance,HF: 16 ohms ,LF bi-amp mode: 8 ohms, LF tri-amp mode: 16 ohms (x2),Sensitivity (1 W @ 1 m) HF: 106 dB LF: 97 dB,Continuous Power Capacity HF: 100 W ,LF bi-amp mode: 400 W, LF tri-amp mode: 200 W (x2),Recommended Power HF: 200 W, LF bi-amp mode: 800 W, LF tri-amp mode: 400 W (x2),Maximum Output (dB SPL at 1 m) Continuous / Peak,HF: 126 dB / 132 dB , LF: 122 dB / 128 dB ,Nominal Coverage Horizontal 140 degrees ,Vertical: dependent on number of elements used. 8 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

3 SITC of Fly-bar for line array & subwoofer , available in black or white

2 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

4 SITC of Pullback bar for line array . For use when pulling back the bottom of the array is necessary to achieve the desired angle, available in black or white.

2 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

5 SITC of 8000W Amplifier using FAST channel combining technology. 4 channels, 1200 watts/ch at 8Ω, 2000 watts/ch at 4Ω, 1600 watts/ch at 2Ω.

4 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

A-2 Subwoofer System

6 SITC of Subwoofer having a Configuration 2 x 18" vented subwoofer Transducer 8 ohm, 18" woofer with a 4" voice coil, ceramic magnet assembly, Frequency Response 31.4 Hz to 240 Hz @ ±3 dB (without processing),Nominal Impedance 4 ohms, Power Capability Continuous: 1700 W, Recommended Power 3000 to 4000 W, Sensitivity 101.5 dB 4 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

Page 7: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 7 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

@ 1 W / 3.3' (1 m),Maximum Output Continuous: 134.5 dB, Peak: 140.5 dB with Mounting Accessories.

7 SITC of 8000W Amplifier using FAST channel combining technology. 4 channels, 1200 watts/ch at 8Ω, 2000 watts/ch at 4Ω, 1600 watts/ch at 2Ω.

2 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

A-3 Powered Stage Monitor System

8 SITC of powered stage monitor having a configuration of 12” Woofer; 1.75” diaphragm compression driver Stage Monitor speaker with Frequency Response (-6 dB) 52 Hz - 18 kHz,Nominal Coverage (-6 dB) 75° conical DMT,Maximum SPL1 131 dB peak,Power Output2 1000 W continuous Class D (500 W LF, 500 W HF) 2000 W peak,Input Impedance XLR / ¼": 40 kΩ balanced / 20 kΩ unbalanced XLR / ¼" MIC mode: 2260Ω balanced RCA: 10 kΩ with complete accesorries. 2 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

A-4 Analog Audio Mixing Console,Digital signal processor , Control room and Green room monitoring

9 SITC of Digital Audio Mixer with 32 inputs (24 mic/line, 6 line in, 1 stereo USB playback), 4-band full parametric EQ, variable high-pass and low-pass filters on all input channels, Gate, compressor and delay on all input channels, 6 professional quality stereo DSP processors plus a pitch corrector, 1/3 octave graphic equalization and 6-band PEQ plus limiters, delay and notch filters on main and aux. outputs, 8 sub-groups with 4-band full parametric EQ, variable high-pass and low-pass filters, compressor. May be linked for stereo, Monitor mixes: 14 mono mixes may be paired for stereo. Two pairs of the auxes can drive wired In Ear Monitors (IEM) directly, 8 DCA groups, 8 mute groups, 8 subgroups, Remote control via mobile devices. Wi-Fi interface included. 1 Nos

Soundcraft, Allen &

Heath/QSC

10 SITC of Ladies Green room -monitoring system Two-way, 6.5" Surface Mount, Weather-resistant,Foreground/Background Loudspeaker with 70/100V transformer & 8Ω bypass, includes mounting hardware, Available in black or white. 2 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

11 SITC of Gents Green room - monitoring system Two-way, 6.5" Surface Mount, Weather-resistant,Foreground/Background Loudspeaker with 70/100V transformer & 8Ω bypass, includes mounting hardware, Available in black or white. 2 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

12 SITC of 2 channels, 185 watts/ch at 8Ω, 280 watts/ch at 4Ω, 430 watts/ch at 2Ω, 300 watts/ch at 70V

1 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

13 SITC of Projection room - monitoring system 1000W active, portable loudspeaker system; 8-inch woofer; 1.75-inch compression driver; 105 degree conical waveguide; Tilt-Direct™ dual angle pole socket, DSP.

1 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

14 SITC of Powder coated steel yoke for mounting the K8 vertically or Horizontally to structures.

1 Nos

QSC /Renkus

Heinz/Meyer Sound/D&B

Page 8: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 8 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

15 SITC of Digital Signal processor with 24 I/O + USB, POTS and VoIP simultaneously,Input Frequency Response 20Hz to 20kHz @ +21dBu :+0.05dB/-0.5dB,Input THD+N @ 1KHz:@ +21 dBu Sensistivity & +21 dBu input ,Input to Input Crosstalk @1kHz:>110dB Typical, 90dB Max,Input Dynamic Range:@ +21 dBu Sensitivity-> 109.5dB,Input Common Mode Noise Rejection:@ +10 dBu Sensitivity:56.5,Input Impedance (balanced):5K Ohms Nominal,Input Sensitivity Range (1dB Steps):-39 dBu min to +21 dBu max,Sampling Rate:48kHz. 1 Nos

Biamp/Toa/QSC

A-5 Microphone System

16 SITC of 10 Channel Frequency-agile True diversity UHF Wireless system with automatic frequency scan Receiver with one ATW-T220 Handheld Transmitter

4 Nos

Audio Technica/Beyerdynamic/Shrue/Senn

heiser

17 SITC of UHF Wireless system with 10 selectable frequencies with frequency scan feature. Ships with ATW-T210 UniPak® transmitter

4 Nos

Audio Technica/Beyerdynamic/Shrue/Senn

heiser

18 SITC of UHF Antennae Distribution system, Supports Upto 4 Wireless Receivers

2 Nos

Audio Technica/Beyerdynamic/Shrue/Senn

heiser

19 SITC of UHF Wide Band Drectional Antennae Pair

2 Nos

Audio Technica/Beyerdynamic/Shrue/Senn

heiser

20 SITC of 30 Mt RF Antenna Cable with BNC- BNC connectors RG8- type cable

4 Nos

Audio Technica/Beyerdynamic/Shrue/Senn

heiser

21 SITC of Closed Back Monitoring Headphones

1 Nos

Audio Technica/Beyerdynamic/Shrue/Senn

heiser

22 SITC of Cardiod Dynamic Microphone

4 Nos

Audio Technica/Beyerdynamic/Shrue/Senn

heiser

23 SITC of Cardiod dynamic instrument microphone

4 Nos

Audio Technica/Beyerdynamic/Shrue/Senn

heiser

24 SITC of 16.46",Cardiod Condenser Gooseneck microphone with RFI shielding

2 Nos

Audio Technica/Beyerdynamic/Shrue/Senn

heiser

25 SITC of Gooseneck Microphone Desk Stand With Switch

2 Nos

Audio Technica/ Beyerdyna

mic/Shrue/Sennheiser

26 SITC of Cardioid Condenser Hanging Microphone with element Fixed-charge back plate, permanently polarized condenser, Polar Pattern Cardioid ,Frequency Response 30-20,000 Hz ,Low Frequency Roll-OFF 80 Hz, 18 dB/octave,Impedance Phantom: 200 ohms Battery: 270 ohms,MAXIMUM INPUT SOUND LEVEL Phantom: 133 dB, 1 kHz at 1% T.H.D. Battery: 123 dB SPL, 1 kHz at 1% T.H.D.Dynamic range (typical) Phantom: 109 dB, 1 kHz at 6 Nos

Audio Technica/ Beyerdyna

mic/Shrue/Sennheiser

Page 9: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 9 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

Max SPL Battery: 99 dB, 1 kHz at Max SPL,SIGNAL-TO-NOISE RATIO 70 dB, 1 kHz at 1 Pa.

27 SITC of Headphone:- Headphone with frequency response 20hz -28khz ,impedance 75ohm ,sensitivity 92dB/mW.

1 Nos

Audio Technica/Beyerdynamic/Shrue/Sennheiser/AKG

28 SITC of Digital Multimedia Lectern with 22" Interactive tablet monitor , Bold, stylish, and robust design, RMS available as an option ,Compatible with all operating systems, multimedia, equipment and teaching materials.Edupen Pro interactive software includes CPU with i7 processor , 1TB HDD , 4GB RAM & Pre Loaded Windows OS 10. 2 Nos

AHA /Oceanz

29 SITC of Stage Box Microphone :-Stage Box complete with Neutrik XLR Connector single 12 Nos Custom

30 SITC of Stage Box Speaker :- Stage Box complete with Neutrik Speakon Connector single 4 Nos Custom

B Video Projection System

1 SITC of Projector 3-chip DLP Projector with Brightness 12500 ANSI lumens ,Contrast 2500:1 ,Native resolution 1920 x 1200 WUXGA , Illumination Dual 450W NSH,Standard inputs Twin DisplayPort input card,Dual-link DVI,optional Dual-link DVI ,Dual 3G SD/HD-SDI Video decoder, Twin HDMI, Analog (5 BNC). 1 Nos

Christie / Sony /NEC

2 SITC of Projector Lens Appropriate Lens to project an image size of 180" (h) x 288" (W) from a throw distance of 30.4 mtr to 50.9mtr . 1 Nos

Christie / Sony /NEC

3 SITC of Projection Screen Low Noise Motorized Professional Projection Screen with matt white fabric of size 180" (h) x 288" (W) with - black drop with IR remote (Reputed brand to be got approved by RGNUL before execution) 1 Nos Custom

4 SITC of Approprite MS Mount for mounting the projector as required as site. 1 Nos Custom

5 SITC of HD Wireless Presentation System with HD Wireless Presentation System, 64 Simulteneous Log-ins, Quad View, Audio Out port 1 Nos

Christie / Oceanz/

WOW

6 SITC of Digital Media HD Recorder inputs VGA / DVI Up to 1366 x 768 ,2 Output Line Level L/R RCA (unbalanced) , DVI ,VGA (RGBHV). Incoading MPEG - 4, Recording - Capture From Camera and VGA input . Live Streming - MPEG 4.RS-232 Control. Access through web browsers. 1 Nos.

Media point /Approved

EQ

7 SITC of PC with 17" TFT Monitor (Any standrd PC) with 500 Gb HDD nad 2 GB RAM & Window XP/7/8/8.1. 1 Nos.

HP/Dell/Sony

8 SITC of PTZ Camera with Full HD 1080p resolution2MP CMOS sensor, 60FPS ,15x optical zoomWide Pan/Tilt/Zoom mechanism ,Connectivity: 3G-SDI, DVI & Component with Joystic Control. 2 Nos.

Lumens/Vivotek / Sony

9 SITC of DVI to HDMi Converter

1 Nos. Crestron/Lightware/AMX

10 SITC of 2x1 DVI Switcher

1 Nos. Crestron/Lightware/AMX

Page 10: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 10 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

11 SITC of HDD Base DVD recorder with Plays any region PAL or NTSC DVD-Video, DVD-Audio, DVD-RAM, DVD+R, DVD-R, and Video CD, Plays audio CD, DVD audio, DiVX, DVD-R, DVD+R, DVD+RW, DVD-RW, and MP3 CD-R & CD-RW, Records in PAL or NTSC, Internal 320GB Hard Disk Drive. 1 Nos.

Sony/Denon/Panasonic/Samsung

12 SITC of Multimedia Hub with HDMI, VGA and Audio input Connectivity . Auto switching single hdmi output . 3 Nos.

Oceanz/Crestron/AMX

13 SITC of Active Wall Plate − HDMI & Computer Graphics with Ethernet, Bidirectional RS−232 & Stereo Audio HDBaseT Transmitter 2 Nos

Crestron/Lightware/AMX

14 SITC of HDMI, Bidirectional RS-232 & IR over Extended Range HDBaseT Twisted Pair Receiver

2 Nos Crestron/Lightware/AMX

15 SITC of 8x8 DigitalMedia Switcher with card.

1 Nos Crestron/Lightware/AMX

16 SITC of HDMI over Twisted Pair Transmitter

2 Nos Crestron/Lightware/AMX

17 SITC of HDMI over Twisted Pair Receiver

2 Nos Crestron/Lightware/AMX

18 SITC of HDMI Audio De-Embedder

1 Nos Crestron/Lightware/AMX

C Control System

1 SITC of Control system processor with 8 port IR I/O or 8 IR/Serial output ports and 8-wire RJ45 jack Ethernet port;2-way device control and monitoring, all ports support RS-232 ,RS-422 or RS-485 also. 1 Nos

Crestron / AMX

2 SITC of Wi Fi Access Point.

1 Nos

D link /Approved

EQ

3 SITC of I-PAD with Software 1 Nos Apple

4 SITC of Din Rail High Voltage Switch. 1 Nos

Crestron / AMX

5 SITC of IR Probes 7 Nos

Crestron / AMX

6 SITC of Control port expansion solution using a single 3-Series Control Card. 1 Nos

Crestron / AMX

7 SITC of 8 port Network Switch

1 Nos

D link /Approved

EQ

D Cable and Connectors

1 SITC of 2.5 Sqmm x 2 core (80/0.20mm) ATC copper Conductor, NCFR- LHC- LSZH Insulated Cores, Vasiform Sheathed Telecom Speaker Cables.

500 Mtr.

Klearcom/ Belden/

Kannare/ Kreppen

2 SITC of 4.0 Sqmm x 2 core (128/0.20mm) ATC copper Conductor, NCFR- LHC- LSZH Insulated Cores, Vasiform Sheathed Telecom Speaker Cables.

200 Mtr.

Klearcom/ Belden/

Kannare/ Kreppen

3 SITC of 18 AWG -24/0.20mm x 2 core ATC Copper Conductor, PVC Insulated, 90 % ATC Copper Braid Shielded, PVC Sheathed Microphone Cable

300 Mtr.

Klearcom/ Belden/

Kannare/ Kreppen

4 SITC of CAT - 6 STP 4 pair Cable - 0.58mm Bare copper , HDPE insulated, ATC Copper Braid Sheilded, PVC Sheathed overall.

600 Mtr.

Klearcom/ Belden/

Kannare/ Kreppen

5 SITC of VGA Cable - 3 coaxial (7/.16mm) ATC Copper Sheilded + 7 Single( 7/0.16mm) cores PVC Sheathed Overall.

30 Mtr.

Klearcom/ Belden/

Kannare/ Kreppen

Page 11: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 11 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

6 SITC of Coaxial Cable for microphone anteena.

150 Mtr.

Klearcom/ Belden/

Kannare/ Kreppen

7 SITC of Patch Cables as required

1 Lot.

Kramer /Approved

EQ

8 SITC of Complete Connectors as required.

1 Lot. Neutrick / Amphenol

9 SITC of 4 Core , 1.5 Sqmm Power cable , No. of strands 48,size of strength 0.2mm ,14 Amp.

150 Mtr.

Havells / Polycab/RR

Kable

10 SITC of Equipment Rack (22"w x 22"d) :-Equipment rack 42U with front glass door, power distribution box, internal fans and lights, wheels etc complete with standard accessories complete as required. 1 Nos. Custom

11 SITC of HD Class 25mm PVC Conduit with Nominal Wall Thickness 2.5mm ,Nominal length 4 meter , 1000 Nos. Akg /Jindal

12 SITC of HD Class 32mm PVC Conduit with Nominal Wall Thickness 2.7mm ,Nominal length 4 meter , 200 Nos. Akg /Jindal

STAGE LIGHTING AND FURNISHING Sr.No

. Item Description Qty. Unit. Approved

Make Rate Amount

A Stage Furnishing

1

SITC of Motorised Main curtain:- Motor: 1 HP Industrial ( Crompton/ Remi/Bharat Bijlee/ equivalent.Air Brake Contactors: 2 nos. (Siemens/ equivalent. Micro Switches for auto Stop: 2 nos.Push Button(one no. near stage & one no. in control room): 3 Position for forward, reverse and stop position.Steel Wire Rope : 3mm Fixing Rail, Brackets and sliding arrangement: in MS Runners, Master Runner and Pulleys: MS Cloth: Velvet/ Crushed of approved quality and colour by architect. Curtain Operation: Horizontal Sliding sideways and overlapping of 900 mm in closed position. (Size:- 175 sq m). Includes curtain control panel to be fixed in control room and 1.5 Sqmm , 4 Core Power Cabling (Makes:-RR Kable/ Polycab/Havells) including MS conduit 1.6 mm thick ISI marked(Makes:-GUPTA/AKG/BEC) from curtain to curtain control panel.(Also require provision for manual control from stage).

1 Nos.

Canara/Oceanz Acoustics/Satan

2

SITC of Motorised rear curtain:Motor: 1 HP Industrial ( Crompton/ Remi/Bharat Bijlee/equivalent. Air Brake Contactors: 2 nos. (Siemens/ equivalent. Micro Switches for auto Stop: 2 nos. Push Button(one no. near stage & one no. in control room): 3 Position for forward, reverse and stop position. Steel Wire Rope : 3mm Fixing Rail, Brackets and sliding arrangement: in MS Runners, Master Runner and Pulleys: MS Cloth: Velvet/ Crushed of approved quality in matt black colour, approved by architect. Curtain Operation: Horizontal Sliding sideways and overlapping of 900 mm in closed position.(Size:-175 sq m).Includes curtain control panel to be fixed in control room and 1.5 Sqmm , 4 Core Power Cabling (Makes:-RR Kable/Polycab/Havells) including MS conduit 1.6 mm thick ISI marked(Makes:-GUPTA/AKG/BEC) from curtain to curtain control panel.(Also require provision for manual control from stage)

1 Nos.

Canara/Oceanz Acoustics/Satan

Page 12: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 12 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

3

SITC of Cyclorama : - MS. Frame structure: 35mm dia MS. Pipe Frame structure with 25 mm MS pipe Ribs between the frame pipes. Structure to be raised from stage floor - 150 to 200 mm; back wall clearance as per drawings. MS Frame structure to be well supported from back wall and /or ceiling. Screen Fabric : White Matt Fabric. Screen to be made in 16:9 ratio format as per the maximum screen size possible on the stage with minimum 200mm black border on all sides for fixing of Eyelets on all sides. Cyclorama to be stretched and tightened from all sides securely using cotton ropes. (Size:-132 Sq m)

1 Nos.

Canara/Oceanz Acoustics/Satan

4

SITC of Stage wings:-Black colour Glazed cotton fire retardant fabric / as approved. Pivoted tube of dia 32mm, with center pivot position. Bottom weights for fabric stretch to be installed appropriately.

4 Nos.

Canara/Oceanz Acoustics/Satan

5

SITC of Frill with bars:-Main front frill bar and subsequent frill bars made of 42 dia MS Pipe Duly supported from the ceiling grid. Frill be stitched in double gathering size as per drawing.( 1 mtr. H x 12 mtr, W)

3 Nos.

Canara/Oceanz Acoustics/Satan

6 SITC of Steel structural grid :- Made out of MS Angle/Pipe in welded construction duly supported from ceiling structure/grid Size - as per drawing. (115 Sq Mtr)

1 Nos.

Canara/Oceanz Acoustics/Satan

7

SITC of Light bars :- Fixed Bar of GI PIPE 50mm B class (Jindal or equivalent). Duly supported from ceiling with MS angles. Suitable no. of 15A sockets as per the Bar position to be provided at 250mm c/c by welding the socket boxes on bar. Lights with c clamps will be hung on the bars and wiring will be done in the sockets. (Size : 17.5 Mtr.)

4 Nos.

Canara/Oceanz Acoustics/Satan

8

SITC of Props bars :- Bar of GI PIPE 50mm B class (Jindal or equivalent) of suitable size, with 6mm rope wire to lift the suitable size /Props/ Sets/ Mic (Load Capicity-400Kg Max. approx.)(Size : 17.5 Mtr.)

4 Nos.

Canara/Oceanz Acoustics/Satan

B Stage Lighting

1

SITC of PRO LED PAR 10Wx18 * Diecast Body*180W* super Bright 10W 4-in-1 RGBW Leds*Tianxin Grade 'A' leds * 18pcs* LCD Display *8 Ch DMX ,Auto&Master Slave*20 deg * High Quality Main PCB with imported Regulator IC * Driver IC which protects the main PCB * Continuos & Steady Electric Current for LED's * True 200W Power Supply * High Quality Double Layer LED PCB with Heavy Duty Aluminium extrusion plate(For FOH)

4 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

2

SITC of PROFILE SPOT LIGHT*360 *Quality profile spot *HPL-575 *With Beam shapers * Bulb:HLP Lamp * Powerful than 1000 watts light * More Brightness & Power Saving * High Pressure Cast Aluminium Case* Infrared Reflectors & Double lens * Homogeneous Focala * Low temperature and light body * Size : 225x425x520mm(For FOH)

4 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

3

SITC of LED WASH 1000 * 7 Ch DMX * 8Wx24 RGB 3 in1 * Auto & DMX * More than 60 degree wash *Wash Effect* Tianxion LED's * Superb Brightness with linear adjustment * Warm Light effects * Size : 400x230x175mm(For FOH)

4 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

4

SITC of STAGE SPOT 1000PC Spot Light* High Quality PC Convex lens * Sturdy Body *1000 Watt (CP-70) Lamp* Heavy Duty Aluminium Diecast* High Efficiency*Higher Brightness*High Quality Lenses(For FOH)

4 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

Page 13: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 13 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

5

SITC of PRO LED PAR 10Wx18 * Diecast Body*180W* super Bright 10W 4-in-1 RGBW Leds*Tianxin Grade 'A' leds * 18pcs* LCD Display *8 Ch DMX ,Auto&Master Slave*20 deg * High Quality Main PCB with imported Regulator IC * Driver IC which protects the main PCB * Continuos & Steady Electric Current for LED's * True 200W Power Supply * High Quality Double Layer LED PCB with Heavy Duty Aluminium extrusion plate(On Stage)

10 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

6

SITC of LED WASH 1000 * 7 Ch DMX * 8Wx24 RGB 3 in1 * Auto & DMX * More than 60 degree wash *Wash Effect* Tianxion LED's * Superb Brightness with linear adjustment * Warm Light effects * Size : 400x230x175mm (For Cyclorama)(On Stage)

6 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

7

SITC of Profile Spot Light *360 *Quality profile spot *HPL-575 *With Beam shapers * Bulb:HLP Lamp * Powerful than 1000 watts light * More Brightness & Power Saving * High Pressure Cast Aluminium Case* Infrared Reflectors & Double lens * Homogeneous Focala * Low temperature and light body * Size : 225x425x520mm(On Stage)

4 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

8

SITC of STAGE SPOT 1000PC Spot Light* High Quality PC Convex lens * Sturdy Body *1000 Watt (CP-70) Lamp* Heavy Duty Aluminium Diecast* High Efficiency*Higher Brightness*High Quality Lenses(On Stage)

4 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

9

SITC of PRO FOG-2000DMX Fog Machine *3000 watts *40000 Cubic Ft per minute *With Remote *With DMX* Manual Controller Electronic thermo switch* Time and Throw Control*Heat up time:10 mins* tank Capacity :2L* Dimension: 53.5x25x14.5cm(On Stage)

2 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

10

SITC of LED MYSTIC * 3 in 1 effect * 8 x 3 White LEDS * 200mW RG Laser * 100mW Green * 200mW Red * 3W RGBWA LED * 24 x 3 watts R(8) G(8) B (8)*Music Controlled Programme * Versatile Grating and Burst Effects * Long Lifespan LED's*Low Heat, Low Power(On Stage)

2 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

11

SITC of 6PACK 2KW Dimmer Pack *6 Ch. *2kW per channel *LCD Display *Direct Dimming*Industry Standard Dimming System * 3 phase operation with Over Voltage Shut Down * DMX512 and analog 0-10V DC inputs*Digital USITT * Digital auto frequency tracking 45Hz-65Hz* Built in Sequnce Mode and Speed Control* Dual Raytech /Pulsar input connectors for analog input* High Quality RFI/EMI suppression

3 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

12

SITC of DMX Controller *12 x 16 ch. *Shape generator *32 banks of 8 scenes *Fixture Library *Independent Seq & Fixture Speed *Programmable Auto delay* Built in Shape Generator* LCD Display for parameters and Menu* Direct Access for scenes and sequence* Single Multi Fixtures Selection *Sync sweep & wave effects *18 faders *Isolated DMX512 output

1 Nos.

Raytech/Zero 88/Strand /Canara/Oceanz Acoustics

13

SITC of Stage Control Desk *72 Channel DMX Stage controller *18 Channel Analog Output *Group Patch Multipple Lights on a single fader* Individual Flash buttons* Fully Programmable non-volatile EEROM Memory* LCD Display*10 pattern sequence* Smooth Alpha Faders* Fully Isolated DMX Output

1 Nos.

Raytech/Zero 88/Strand /Canara/Oceanz Acoustics

14

SITC of DMX Splitter *1 In / 4 Outs *LED showing faulty ch. *With Opto isolated ouput*Each zone having upto 32 devices* Status indication on each zone for Powersupply and DMX

1 Nos. Raytech/Zero 88/Strand

Page 14: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 14 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

15 SITC of GI Lights Clamps for suspending above lights from the light bar, Black Powder coated.

44 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

16 SITC of Solid 3 pole Male/female cable XLR Connectors with with locking ring and coaxial shell.

50 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

17 SITC of DMX Cable with 18 AWG -24/0.20mm x 2 core ATC Copper Conductor, PVC Insulated, 90 % ATC Copper Braid Shielded, PVC Sheathed control Cable.

44 Nos.

Satan/Clay Paky/ Robe/Canara/Oceanz Acoustics

18

SITC of Stage light Points : Light point wiring from patch panel on one side of stage wall to various stage light fixtures with 2.5 sqmm 3 core PVC insulated and PVC sheathed ISI mark cable (Makes:-RR Kable/Polycab/Havells) of suitable size including drop length from light bar to stage floor including MS conduit 1.6 mm thick ISI marked(Makes:-GUPTA/AKG/BEC) includes MS box approximate size 5" x 3 " with modular plate(Make:-Northwest-convex/Legrand-Myrius) and ISI mark 15 Amp. socket and top for each light.

44 Nos. Custom

19

SITC of Cabling for control cable for stage lighting from control to dimmer pack (Stage to control room) .18 AWG -24/0.20mm x 2 core ATC Copper Conductor, PVC Insulated, 90 % ATC Copper Braid Shielded, PVC Sheathed control Cable , Dmx inter wiring connection for patch panel to dimmer and dimmer to control room with required connector including conduiting.

1 Job Job

DIGITAL SIGNAGE SYSTEM

Sr.No. Item Description Qty. Unit. Approved Make

A For Prefunction Area

1

SITC of Flat Panel Display size 84" Diagonal Resolution 3840x2160, Display Colors 1.07B, Brightness 350cd/m2, Contrast Ratio 1600:1, Viewing Angle 178deg H/V, Backlight type LED, Refresh Rate 60Hz, Response Time 5ms, Complete with Wall/Floor Mounting hardware as required.

1 Nos Christie /Barco/Planar

B For VIP Area

1

SITC of 42” LED Commercial Monitor with Full HD 1920 x 1080p Native Resolution, ,IPS Panel Technology ,Direct LED Backlit Display ,Brightness of 300 cd/m2 ,Supports Portrait & Landscape Modes ,Embedded Media Player ,Inputs Include HDMI, RGB & USB ,Wide 178° x 178° Viewing Angle ,Remote Control via RS-232C & Networkrequired.

1 Nos Samsung /LG / Hyundai

Page 15: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 15 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

C For Green Room Area

1

SITC of 42” LED Commercial Monitor with Full HD 1920 x 1080p Native Resolution, ,IPS Panel Technology ,Direct LED Backlit Display ,Brightness of 300 cd/m2 ,Supports Portrait & Landscape Modes ,Embedded Media Player ,Inputs Include HDMI, RGB & USB ,Wide 178° x 178° Viewing Angle ,Remote Control via RS-232C & Network

2 Nos Samsung /LG / Hyundai

D Stage Monitor

1

SITC of Flat Panel Display size 84" Diagonal Resolution 3840x2160, Display Colors 1.07B, Brightness 350cd/m2, Contrast Ratio 1600:1, Viewing Angle 178deg H/V, Backlight type LED, Refresh Rate 60Hz, Response Time 5ms, Complete with Wall/Ceiling Mounting hardware as required.

2 Nos Christie /Barco/Planar

2 SITC of 1:2 HDMI Distribution Amplifier 1 Nos Crestron/Lightware/AMX

3 SITC of HDMI over Twisted Pair Transmitter 5 Nos Crestron/Lightware/AMX

4 SITC of HDMI over Twisted Pair Receiver 5 Nos Crestron/Lightware/AMX

GENERAL LIGHTING

Sr.No. Item Description Qty. Unit. Approved Make

1

SITC of Alume XXL Fixed Dark with 26W, 3000°K LED, 20° reflector, white finish. 1-10V Dimmable power supply. 22(on UPS)+100

122 Nos. iGuzzini, IBL, Led Linear, Oceanz

2 SITC of Accent recessed Wall LED Step luminaire with 3W, 3000°K and electronic control gear.

140 Nos. Crompton/Philips/Wipro

3 SITC of Digital Dimmer for the above Lights with Control Panel and Universal/Automatic Interface

1 Nos. Crestron/Amx/Oceanz

4

SITC of 2.5 Sqmm ,2 core power cable (Makes:-RR Kable/Polycab/Havells) for Electrical wiring for above light including MS conduit 1.6 mm thick ISI marked(Makes:GUPTA/AKG/BEC),Bends, j box etc On Surface

500 Mtr. approved make

5

SITC of 2.5 Sqmm ,2 core power cable(Makes:-RR Kable/Polycab/Havells) for Electrical wiring for step lights including MS conduit 1.6 mm thick ISI marked(Makes:GUPTA/AKG/BEC),Bends, j box etc.Recessed in steps or laying surface on wall by floor cutting(cheasiling) & restoration in original shape(good to funish).

400 Mtr. approved make

6 SITC of control cable from 26W led light (item no.1) to digital dimmer in control room including heavy gauge PVC conduit pipe 25 mm

400 MTR. approved make

Page 16: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 16 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

UPS AND PANEL

Sr.No. Item Description Qty. Unit. Approved Make

UPS 20 KVA

1

SUPPLYING, testing & commissioning of 20 KVA True Online double conversion and fully Microprocessor Controlled UPS system with IGBT Rectifier including RS 485 Modbus Communication port with inbuilt galvanic and electronic isolation at the output with accessories and suitable Power Management software in each UPS as per specification Suitable for AV SYSTEM

1 NOS Numeric/ Emerson/ APC

UPS SYSTEM ALONG WITH SMF BATTERY BACKUP USING 12V BATTERIES OF APPROVED MAKE EQVT MAKE, DISCONNECTOR FOR BATTERY PROTECTION, MS RACK, INTERLINKS AND DC CABLE UPTO 5 MTRS FROM UPS TO BATTERIES.

12vdc, 42Ahx30 Nos./UPS / as per vender calculation

including Supplying , testing & commissioning of APPROVED MAKES 20 KVA 3PH-3PH TRUE ONLINE UPS SYSTEM (Standalone) ALONG WITH SMF BATTERY OF 12V-26 AH-30 NOS FOR UPTO 30 MIN. BACK-UP BATTERY AS PER APPROVED MAKE , UPS- APPROVED MODEL WITH MS RACK,INTERLINKS AND DC CABLE UPTO 5 MTRS FROM UPS TO BATTERIES.

SPECIAL FEATURES :

IGBT BASED RECTIFIER AND INVERTER

INPUT VOLT 415V - 15% + 10%, THREE PHASE 4 WIRE

OUTPUT VOLT 415V +/- 1%, THREE PHASE 4 WIRE

OVERALL EFFICEINCY UPTO 94%

OUTPUT FREQUENCY 50 HZ +/- 0.1 HZ

Page 17: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 17 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

INPUT POWER FACTOR >0.99, CURRENT HARMONICS <3%

OUTPUT POWER FACTOR 0.9 LAGGING

INBUILT ISOLATION TRANSFORMER

SUPPLYING OF BATTERY ACCESSORIES

a) Battery Rack for 20 KVA UPS

b)Battery Interconnecting Links for 20 KVA UPS

c) Battery to UPS Cable (Maximum 5 meters) for 20 KVA UPS

d) Battery Fuse Box for 20 KVA UPS.

e) INSTALLATION AND COMMISSIONING OF 20 KVA UPS WITH BATTERY AND ACCESSORIES

2 CABLE TRAY

Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

Makes as per Volume.1

300 mm width X 50 mm depth X 1.6 mm thickness

700 Mtr.

600 mm width X 75 mm depth X 2.0 mm thickness

150 Mtr.

3 ANGLE/FLAT IRON AND STEEL SHEET FOR SUPPORTING

50 mm X 50 mm X 6 mm angle iron 100 kg

40 mm X40 mm X 6 mm angle iron 100 kg

40 mm X 3 mm flat iron 200 kg

PIPE

4

Supply and erection of double walled corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation (making necessary trench), placing the pipe in position and back filling with excavated soil etc. of the required size.

Double walled corrugated (DWC) HDPE pipe 63/ 51mm (outer/ inner dia.)

50 Mtr.

Double walled corrugated (DWC) HDPE pipe90/76mm(outer/ inner dia.)

20 Mtr.

Page 18: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 18 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

Double walled corrugated (DWC) HDPE pipe 120/103.5mm (outer/ inner dia.)

20 Mtr.

Double walled corrugated (DWC) HDPE pipe 160/ 136mm(outer/ inner dia.)

20 Mtr.

FLOOR PANELS

5

Supply only, Testing and commissioning of indoor type cubicle pattern L T Switch-Board with a rupturing capacity of 50 KA at 415 V or as called for in individual items, openable in front and back suitable for 3 phase, 4 wire, 50Hz AC supply at an ambient temperature of 45 C. The cubicle should be weather proof, dust proof vermin proof, well ventilated and enclosure protection shall be IP-54 as per IS 2147-1962.or as per CPWD specifications, ( Part IV - Sub-station) and IS: 8623 The cubicle should be front operated, floor mounted, free standing with compartments in tier formation, extensible on both sides. The panel to be provided with PVC Sleeved TPN Electrolytic Al. ( CD 0.8A/sq.mm. ) Bus Bar and PVC insulated solid interconnections and also provided with 50x6mm. horizontal GI Earth Bus Bars in each section.(as per drawing- enclosed) - AV SYSTEM at AUDITORIUM Note:-all mccb should be thermal magnetic type and minimum 25 ka rating.(Schneider/L&T/Seimens)

ETE/ONIDA/ NEPTUNE/KRYPTON (Panel builder should be CPRI approved)

A) Incoming

i) 1 Nos. 125 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle connected from Main audi panel

PROTECTION INSTRUMENT

i) 1 set of phase indication lights.

ii) 1 sets of indication lights, breaker ON-OFF etc.

iii) multi function meter with RS485 port

iv) 1set of CT's

iv) Bus bar :- 200 Amps TP&N 50 kA aluminum conductor bus bar (PVC Heat-shrinkable busbar insulation) supported by DMC / FRP insulators.

OUTGOING-on indication light with 2 amp MCB for each outgoing

i) 3 Nos. 32 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle.

ii )3 nos 40 amp DP RCBO,100ma

iii) 1 6 Nos. 32 Amps, 10 ka, SPN MCB

Page 19: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 19 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

iv)1 no 10 watt LED light with switch &16a switch +16 amp socket

1 set

6

Supply only, Testing and commissioning of indoor type cubicle pattern L T Switch-Board with a rupturing capacity of 50 KA at 415 V or as called for in individual items, openable in front and back suitable for 3 phase, 4 wire, 50Hz AC supply at an ambient temperature of 45 C. The cubicle should be weather proof, dust proof vermin proof, well ventilated and enclosure protection shall be IP-54 as per IS 2147-1962.or as per CPWD specifications, ( Part IV - Sub-station) and IS: 8623 The cubicle should be front operated, floor mounted, free standing with compartments in tier formation, extensible on both sides. The panel to be provided with PVC Sleeved TPN Electrolytic Al. ( CD 0.8A/sq.mm. ) Bus Bar and PVC insulated solid interconnections and also provided with 50x6mm. horizontal GI Earth Bus Bars in each section.(as per drawing- enclosed)) - VENTILATION PANEL ON DG at AUDITORIUM Note:-all mccb should be thermal magnetic type and minimum 25 ka rating.(Schneider/L&T/Seimens)

ETE/ONIDA/ NEPTUNE/KRYPTON (Panel builder should be CPRI approved)

A) Incoming

i) 1 Nos. 260 Amps TPN MCCB adjustable Thermal magnetic release with with rotary handle connected from Main audi panel

PROTECTION INSTRUMENT

i) 1 set of phase indication lights.

ii) 1 sets of indication lights, breaker ON-OFF etc.

iii) multi function meter with RS485 port

iv) 1set of CT's

iv) Bus bar :- 300 Amps TP&N 50 kA aluminum conductor bus bar (PVC Heat-shrinkable busbar insulation) supported by DMC / FRP insulators.

OUTGOING-on indication light with 2 amp MCB for each outgoing

i) 5 Nos. 100 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle.

ii) 3 Nos. 63 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle.

iii) 2 Nos.25 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle.

Page 20: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 20 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

iv)1 no 10 watt LED light with switch &16a switch +16 amp socket

1 set

7

Supply only, Testing and commissioning of indoor type cubicle pattern L T Switch-Board with a rupturing capacity of 50 KA at 415 V or as called for in individual items, openable in front and back suitable for 3 phase, 4 wire, 50Hz AC supply at an ambient temperature of 45 C. The cubicle should be weather proof, dust proof vermin proof, well ventilated and enclosure protection shall be IP-54 as per IS 2147-1962.or as per CPWD specifications, ( Part IV - Sub-station) and IS: 8623 The cubicle should be front operated, floor mounted, free standing with compartments in tier formation, extensible on both sides. The panel to be provided with PVC Sleeved TPN Electrolytic Al. ( CD 0.8A/sq.mm. ) Bus Bar and PVC insulated solid interconnections and also provided with 50x6mm. horizontal GI Earth Bus Bars in each section.(as per drawing- enclosed)) - AC PANEL ON NORMAL SUPPLY at AUDITORIUM Note:-all mccb should be thermal magnetic type and minimum 25 ka rating.(Schneider/L&T/Seimens)

ETE/ONIDA/ NEPTUNE/KRYPTON (Panel builder should be CPRI approved)

A) Incoming

i) 1 Nos. 200 Amps TPN MCCB adjustable Thermal magnetic release with with rotary handle connected from Main audi panel

PROTECTION INSTRUMENT

i) 1 set of phase indication lights.

ii) 1 sets of indication lights, breaker ON-OFF etc.

iii) multi function meter with RS485 port

iv) 1set of CT's

iv) Bus bar :- 300 Amps TP&N 50 kA aluminum conductor bus bar (PVC Heat-shrinkable busbar insulation) supported by DMC / FRP insulators.

OUTGOING-on indication light with 2 amp MCB for each outgoing

i) 2 Nos. 160 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle.

ii) 2 Nos. 32 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle.

iii)1 no 10 watt LED light with switch &16a switch +16 amp socket

1 set

Page 21: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 21 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

8

Supply only, Testing and commissioning of indoor type cubicle pattern L T Switch-Board with a rupturing capacity of 50 KA at 415 V or as called for in individual items, openable in front and back suitable for 3 phase, 4 wire, 50Hz AC supply at an ambient temperature of 45 C. The cubicle should be weather proof, dust proof vermin proof, well ventilated and enclosure protection shall be IP-54 as per IS 2147-1962.or as per CPWD specifications, ( Part IV - Sub-station) and IS: 8623 The cubicle should be front operated, floor mounted, free standing with compartments in tier formation, extensible on both sides. The panel to be provided with PVC Sleeved TPN Electrolytic Al. ( CD 0.8A/sq.mm. ) Bus Bar and PVC insulated solid interconnections and also provided with 50x6mm. horizontal GI Earth Bus Bars in each section.(as per drawing- enclosed)) - AC PANEL ON DG SUPPLY at AUDITORIUM Note:-all mccb should be thermal magnetic type and minimum 25 ka rating.(Schneider/L&T/Seimens)

ETE/ONIDA/ NEPTUNE/KRYPTON (Panel builder should be CPRI approved)

A) Incoming

i) 1 Nos. 200 Amps TPN MCCB adjustable Thermal magnetic release with with rotary handle connected from Main audi panel

PROTECTION INSTRUMENT

i) 1 set of phase indication lights.

ii) 1 sets of indication lights, breaker ON-OFF etc.

iii) multi function meter with RS485 port

iv) 1set of CT's

iv) Bus bar :- 300 Amps TP&N 50 kA aluminum conductor bus bar (PVC Heat-shrinkable busbar insulation) supported by DMC / FRP insulators.

OUTGOING-on indication light with 2 amp MCB for each outgoing

i) 2 Nos. 160 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle.

ii) 3 Nos. 32 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle.

iii) 1 No.25 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle.

iv)1 no 10 watt LED light with switch &16a switch +16 amp socket

1 set

Page 22: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 22 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

9

Supply only, Testing and commissioning of indoor type cubicle pattern L T Switch-Board with a rupturing capacity of 50 KA at 415 V or as called for in individual items, openable in front and back suitable for 3 phase, 4 wire, 50Hz AC supply at an ambient temperature of 45 C. The cubicle should be weather proof, dust proof vermin proof, well ventilated and enclosure protection shall be IP-54 as per IS 2147-1962.or as per CPWD specifications, ( Part IV - Sub-station) and IS: 8623 The cubicle should be front operated, floor mounted, free standing with compartments in tier formation, extensible on both sides. The panel to be provided with PVC Sleeved TPN Electrolytic Al. ( CD 0.8A/sq.mm. ) Bus Bar and PVC insulated solid interconnections and also provided with 50x6mm. horizontal GI Earth Bus Bars in each section.(as per drawing- enclosed)) - UPS PANEL at AUDITORIUM-CONTROL ROOM Note:-all mccb should be thermal magnetic type and minimum 25 ka rating.(Schneider/L&T/Seimens)

ETE/ ONIDA/ NEPTUNE / KRYPTON (Panel builder should be CPRI approved)

A) Incoming

i) 3 Nos. 100 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle connected from Main audi panel -1 for normal supply and second for DG supply

ii) 2 nos 4 pole 125 amp contactor with interlocking

iii) 1 no 100 amp ,4pole bypass switch

Iv) 1 Nos. 100 Amps TP MCCB adjustable Thermal magnetic release with 200 amp neutral link with rotary handle

PROTECTION INSTRUMENT

i) 1 set of phase indication lights.

ii) 3 sets of indication lights, breaker ON-OFF etc.

iii) 1 no multi function meter with RS485 port

iv) 1set of CT's

v) Bus bar :- 300 Amps 4 pole 50 kA aluminum conductor bus bar (PVC Heat-shrinkable busbar insulation) supported by DMC / FRP insulators.

OUTGOING-on indication light with 2 amp MCB for each outgoing

i) 5 Nos. 63 Amps TPN MCCB adjustable Thermal magnetic release with rotary handle.

ii)1 no 10 watt LED light with switch &16a switch +16 amp socket

1 Set

Page 23: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 23 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

Item Description Unit Approx

Qty. Approved makes

Auditorium Ceiling Treatment

1 Acoustic Treatment for Auditorium Ceiling (Color - White): Providing & fixing in position, Acoustical ceiling tiles should have Humidity Resistance (RH) of 95%, NRC 0.90, Color - White, material - fibre glass, Fire Performance UK Class 0 / Class 1 in module size of 600 x 600 x 20mm with coating on the face of the tile, suitable for Green Building application, with Recycled content of 66% GW & 74% RW%. The tile shall be laid on 24 mm wide T - section flanges color White having rotary stitching on all T sections i.e. the Main Runner 1200 mm & Cross Tees 600 mm with a web height of 32mm and a load carrying capacity of 15.34Kgs/M2. All G.I. Sections have a Galvanizing of 120 grams per M2 (min. coating 0.3 mm) & passed through 500 hrs of Salt test. Grid system comprise main runner spaced at 1200mm centers securely fixed to the structural soffit with suitable hangers ( to be approved by Engineer in charge) .Flush fitting 1200mm long cross tees to be interlock b/w main runners at 600mm centre perform 600 x 600mm module. perimeter trim to be of wall angles size 3000 x 19 x19 mm scared to wall at 450mm max. centers. Using T grid system including cost of required cut-outs, suspension system, decorative moldings / finishing- items & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. All Makes and models of all items/samples should be approved by the consultant prior to the installation. (Approx coverage 50% of the ceiling). Hangers spacing should not exceed 1200mm c/c both ways unless otherwise approved by Engineer in charge.

Sq. m 464 Armstrong/ Oceanz Acoustics/ Hunter

Douglas/ Ecophon/ Dexune

Page 24: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 24 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

2 POP Ceiling: Providing and Fixing, Plaster of Paris false ceiling shall be 12 mm thick POP layer fixed on G.I. press metal section with suspension system which include G.I. hangers. Additional frame work shall have to be done for providing trap door, cutouts for A.C. grills, openings for smoke and heat detection and lights etc. All material to be approved by the Acoustic Consultant prior to installation. The exposed plaster of Paris surface shall be painted with approved shade of Plastic Emulsion paint. (Approx coverage 50% of the ceiling). All G.I. press metal sections / material / P O P to be got approved from Engineer in charge before execution as shop drawing to be submitted by the agency .

Sq. m 529 Custom

3 Acoustic Treatment for Under Balcony Ceiling (Color -White): Acoustic Treatment for Auditorium Ceiling (Color - White): Providing & fixing in position, Acoustical ceiling tiles should have Humidity Resistance (RH) of 95%, NRC 0.90, Color - White, material - fibre glass, Fire Performance UK Class 0 / Class 1 in module size of 600 x 600 x 20mm with coating on the face of the tile, suitable for Green Building application, with Recycled content of 66% GW & 74% RW%. The tile shall be laid on 24 mm wide T - section flanges color White having rotary stitching on all T sections i.e. the Main Runner 1200 mm & Cross Tees 600 mm with a web height of 32mm and a load carrying capacity of 15.34Kgs/M2. All G.I. Sections have a Galvanizing of 120 grams per M2 (min. coating 0.3 mm) & passed through 500 hrs of Salt test. Grid system comprise main runner spaced at 1200mm centers securely fixed to the structural soffit with suitable hangers ( to be approved by Engineer in charge) .Flush fitting 1200mm long cross tees to be interlock b/w main runners at 600mm centre perform 600 x 600mm module. perimeter trim to be of wall angles size 3000 x 19 x19 mm scared to wall at 450mm max. centers. Using T grid system including cost of required cut-outs, suspension system, decorative moldings / finishing- items & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. All Makes and models of all items/samples should be approved by the consultant prior to the installation. (Approx coverage 50% of the ceiling). Hangers spacing should not exceed 1200mm c/c both ways unless otherwise approved by Engineer in charge.

Sq. m 185 Armstrong/ Oceanz Acoustics/ Hunter

Douglas/ Ecophon/ Dexune

Stage Ceiling Treatment

4 Acoustic Treatment for StageCeiling : Providing and fixing of magnesite bonded woodwool panels made with superfine wood fibres & gypsum, were patented with magnesite cement, edge profiles consist of Radius, Chamfer, Tongue-Groove & H-Spline groove, having density 400kg/m3, Acoustic NRC upto 0.90, eco-friendly, Fire Ratings - Non-combustibility At 750 oC, Thermal Resistance, Water Vapour Diffusion Resistant, size 600 x 600/ 1200/ 2400 x 25 mm installed on Strut C-system requires unfastening and refastening of fasteners. All material to be approved by the Acoustic Consultant prior to installation. The Strut C-System framework consisting of CC10 Channels fixed at 600mm centres, Long edges chamfer and kerfed for H-Spline; Thickness 38 mm installed on Strut C-system with H-Spline.

Sq. m 109 Armstrong/ Oceanz Acoustics/ Hunter

Douglas/ Ecophon/ Dexune

Auditorium Walls Treatment

Page 25: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 25 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

5 Acoustic Treatment for Low Frequency Absorption for Audi both sides & back Wall: Providing and Fixing Channeled Woodworks perforated panels of width 128mm, thickness of 18mm and length 2440 mm or as required by the Architect/ acoustic consultant, made of a high density particle board substrate with a laminated facing as per the approved shade/ species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern 13/3 (12.8% perforation rate) . The panels shall provide a minimum sag resistance of RH90 and a fire rating 0.85 NRC. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. Installation of Woodwork perforated panels on GI Channels of section 50mm x 50mm on GI pipe frame factored at Sl. No. 10. GI panels fixed horizontally at spacing of 600mm center to centre and screwed aluminum extruded keel for channeled wood works with 50mm thick thermal banded polyester non-woven wadding Mikron fiber of 1000 gm/sqm. The mikron fiber to be held in position with chicken wire mesh. The final color of the material and design horizontal orvertical to be approved by the consultant and the architect both to ensure the final looks of the installation is as per the design intended for, contractor to take a final sign off before start of work . The panels shall be mounted on special aluminum splines using clips. All Makes and models of all items/samples should be approved by the consultant prior to the installation.

Sq. m 462 Armstrong/ Oceanz Acoustics/ Hunter

Douglas/ Ecophon/ Dexune

6 Acoustic Diffusion for side walls: Providing and fixing MLS design Diffusion panels of width 600 mm, length 1200mm and thicknes 38mm, made of Rubber solid wood, density board, finish with original wood texture/ required color, frequency range 500Hz-4000Hz, Environmental performance grade: E1(GB). Installation of MLS Diffusion panels on GI Channels of section 50mm x 50mm on GI pipe frame factored at Sl. No. 10. GI panels fixed horizontally at spacing of 600mm center to centre and screwed aluminum extruded keel for channeled wood works with 50mm thick thermal banded polyester non-woven wadding Mikron fiber of 1000 gm/sqm. The mikron fiber to be held in position with chicken wire mesh. The final color of the material and design horizontal orvertical to be approved by the consultant and the architect both to ensure the final looks of the installation is as per the design intended for , contractor to take a final sign off before start of work . The panels shall be mounted on special aluminum splines using clips. All Makes and models of all items/samples should be approved by the consultant prior to the installation.

nos. 32 Armstrong/ Oceanz Acoustics/ Hunter

Douglas/ Ecophon/ Dexune

7 Acoustic Treatment for Mid & High Frequency Absorption for Audi both sides & back Wall: Providing and fixing Acoustical Wall Paneling’ with square edges made of fiber glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire-resistant fabric with an option of colors as per the choice of the Architect/Acoustic consultant of size 2100x600 mm providing a minimum sound absorption level of 0.95 NRC. Installation of Acoustic Fabric panels on GI frame work of section 50mm x 50mm on GI pipe frame factored at Sl. No. 10. GI panels fixed horizontally at spacing of 600mm center to centre and screwed aluminum extruded keel for channeled wood works. 6mm thick BWP ply (Duro/ century / Green) to be fixed on the frame work. Wall panel impellers shall be fixed to the GI frame using self taping screws. Wall panel impellers and construction adhesives as per the instructions lay down by the manufacturer. All makes and models of all items/samples should be approved by the consultant prior to the installation.

Sq. m 482 Armstrong/ Oceanz Acoustics/ Hunter

Douglas/ Ecophon/ Dexune

Stage Walls Treatment

Page 26: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 26 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

8 Acoustic Treatment for Stage both Sides & Back wall: Providing and fixing of magnesite bonded woodwool panels made with superfine wood fibres & gypsum, were patented with magnesite cement, edge profiles consist of Radius, Chamfer, Tongue-Groove & H-Spline groove, having density 400kg/m3, Acoustic NRC upto 0.90, eco-friendly, Fire Ratings - Non-combustibility At 750 oC, Thermal Resistance, Water Vapour Diffusion Resistant, size 600x600/1200/2400x25mm installed on Strut C-system requires unfastening and refastening of fasteners . The Strut C-System framework consisting of CC10 Channels fixed at 600mm centres, Long edges chamfer and kerfed for H-Spline; Thickness 38 mm installed on Strut C-system with H-Spline. To be fixed on GI frame work of section 50mm x 50mm on GI pipe frame factored at Sl. No. 10. GI Frame in fill with 50mm thick thermal banded polyester non-woven wadding Mikron fiber of 1000 gm/sqm. The mikron fiber to be held in position with chicken wire mesh. All material to be approved by the Acoustic Consultant prior to installation.

Sq. m 260 Armstrong/ Oceanz Acoustics/ Hunter

Douglas/ Ecophon/ Dexune

9 Skirting: Providing & fixing 150 mm Skirting out of 12 mm thick BWP ply board of reputed make . with 1.5 mm laminate (Duro/ century / Green) of approved shade, to be fixed as per the drawings on framework of 50 X 50 mm GI frame fixed at 300(v) x 600(h)mm (or wherever required as per design drawing) centre jointed with each other with GI cleats & drive all screws. The Framework to be supported on the wall at the interval of 1800mm centre to centre with 40x40x5mm angle cleats / fasteners of required length (MS anchor fasteners of size 65mm x 10 mm dia.) The entire work to be executed as per the drawings /Acoustic consultant, instructions of the Engineer-in-change. All Makes and models of all items/samples should be approved by the consultant prior to the installation.

RM 160 Custom

GI Frame behind Wall paneling

10 Providing & fixing of GI Frame consisting of 16 gauge GI Pipe 50 x 50 mm, fixed horizontally between the two vertical columns at all partition walls of the Auditorium. Both ends of the pipes should have suitable metal plate welded for holding. Gap between two horizontal pipes should be 1 mts. Pipes to be fixed firmly with approx. size fasteners to hold the weight of wall frame & wall panels properly. Complete with all accessories as required at site. All Makes and models of all items/samples should be approved by the consultant prior to the installation.

RM 1500 Custom

Acoustic Doors

11 Acoustic Door [2000 (W) x 2550 (H)] : Providing and fixing of teakwood door 75mm (nominal) along with fire and smoke Intumescent seal strip of size 12mm x 4mm for 120 minutes fire rated and Rw rating acoustic door with minimum 75mm thickness having infill of 45mm thick resin bonded fibreglass of 48 kg/m3 density sandwiched by two 12mm thick non- combustible fire rated boards (edge to edge on internal hardwood frame) and cladded with 6mm thick commercial ply facing and 3mm sheet rubber interlayer and finished with 1mm thick laminate/as per architect. All material to be approved by the Acoustic Consultant prior to installation. The board shall be Resistant to vermin, mould growth, minor impact, abrasion and short term water attack and shall be off-white in color with a smooth surface suitable to receive most forms of decoration. Should include door closer, coordinator, Panic Bar, 5” Ball Bearing Hinges(SS) (4 nos. for each leaf of door) and Door Handle as per architect both for single and double doors. Excludes the cost of external Automatic Drop down seals & perimeter seals (approved make - CCE italy/ Lorient).

nos 12 Custom

Flooring

Page 27: TENDER DOCUMENTamp or tri-amp mode, Bi-amp or Tri-amp, Transducer High Frequency Dual 50 W, 8 ohm 1" exit, 1.75" titanium diaphragm, neodymium magnet assembly, Low FrequencyDual 200

Page 27 of 27

CONTRACTOR/CONTRACTING AGENCY WITNESS REGISTRAR

12 Stage Flooring: Providing and fixing 75x19 mm teakwood plank (900mm long) flooring with tongue and groove joints (concealed screwing and minimum length 1.5m), comprising 75x12mm BWP ply board (Duro/ century / Green) 600mm x 600mm centre to centre support locations including providing and applying a coat of ready mixed primer and a coat of Fire resistant paint both of approved brand and manufacturer over exposed surfaces . Entire work to be done complete as per drawings, specifications and direction of Engineer-in-Charge including melamine polishing of teak wood planks after filling wood filler and sand papering up to smooth finish in natural colour. Stage Floor - Moulding : Providing and fixing 145x50mm teakwood moulding as per architect on the edges of stage wooden flooring including melamine polishing of teak wood planks after filling wood filler and sand papering up to smooth finish in natural colour.The final color of the material and design horizontal orvertical to be approved by the consultant and the architect both to ensure the final looks of the installation is as per the design intended for , contractor to take a final sign off before start of work All Makes and models of all items/samples should be approved by the consultant prior to the installation.

Sq. m 174 Custom

Annual Maintenance Contract

1. Additional Two year Annual Maintenance contract (AMC) after completion of three year warranty period For the complete Audio, Video, Acoustic and Lightning of Auditorium

Lot 1