tender package drawings in order of ......tender package drawings in order of arrangement:...
TRANSCRIPT
TENDER PACKAGE DRAWINGS IN ORDER OF ARRANGEMENT:ARCHITECTURAL DRAWINGS (9 PAGES)ELECTRICAL DRAWINGS (6 PAGES)MECHANICAL DRAWINGS (15 PAGES)
MOODY PARK
CENTURY HOUSE
NEW WESTMINSTER LAWN
BOWLING CLUB
MOODY PARK
POOL
P
R
I
N
C
E
S
S
S
T
S
I
X
T
H
A
V
E
N
U
E
S
E
V
E
N
T
H
S
T
H
A
M
I
L
T
O
N
S
T
E
I
G
H
T
H
A
V
E
N
U
E
E
I
G
H
T
H
S
T
1
0
T
H
S
T
N
A
N
A
I
M
O
S
T
S
E
V
E
N
T
H
A
V
E
H
A
M
I
L
T
O
N
S
T
K
I
N
G
S
T
O
N
S
T
E
I
G
H
T
H
A
V
E
N
U
E
N
I
N
T
H
S
T
S
I
X
T
H
A
V
E
N
U
E
E
I
G
H
T
H
S
T
E
I
G
H
T
H
S
T
E
D
I
N
B
U
R
G
H
S
T
SCOPE OF
WORK
PROJECT DIRECTORY
ARCHITECT
IREDALE ARCHITECTURE
220 - 12 WATER STREET
VANCOUVER BC
V6B 1A5
T: 604.736.5581
F: 604.736.5585
CONTACT: KENDALL B. JESSIMAN
CENTURY HOUSE
AIR CONDITIONING SYSTEM ADDITION
620 EIGHTH STREET, NEW WESTMINSTER, BC V3M 3S6
PROJECT No. 19028
25 MAR 2019 | ISSUED FOR TENDER
CE
NT
UR
Y H
OU
SE
AIR
C
ON
DIT
IO
NIN
G S
YS
TE
M A
DD
IT
IO
N
620 E
IG
HT
H S
TR
EE
T, N
EW
W
ES
TM
IN
ST
ER
, B
C V
3M
3S
6
PR
OJE
CT
N
o. 19028
25
M
AR
2
01
9 | IS
SU
ED
F
OR
T
EN
DE
R
RE
DA
LE
AR
CH
TE
CT
UR
E
I
I
22
0 - 1
2 W
ate
r S
tre
et V
an
co
uve
r, B
C V
6B
1
A5
60
4 - 7
36
- 5
58
1 V
an
co
uve
r V
icto
ria
CLIENT
CITY OF NEW WESTMINSTER
511 ROYAL AVENUE
NEW WESTMINSTER BC
V3L 1H9
T: 604.527.4597
C: 604.841.7870
CONTACT: WAYNE WERBOVETSKI
LOCATION PLAN
N
SCALE: N.T.S.
PROJECT STATISTICS
LEGAL DESCRIPTION:
MOODY SQUARE PLAN 2620
SCOPE:
THIS IS AN AIR-CONDITIONING PROJECT
THAT INVOLVES FAIRLY COMPLEX ARRAY
OF HEAT PUMPS OR SPLIT SYSTEM,
CONDENSING UNITS, STANDALONE
UNITS ON THE INSIDE AND UNITS
OUTSIDE AND WALL PENETRATIONS
AND FURRED OUT WALLS, ETC.
ELECTRICAL
E-0 DRAWING LIST, MECH. SCHEDULEAND SINGLE LINE
E-1 PARTIAL POWER PLAN - BASEMENT
E-2 PARTIAL POWER PLAN -LEVEL 1
E-2 PARTIAL POWER PLAN - ROOFE-4 PANEL SCHEDULESE-5 ELECTRICAL SPECIFICATION
MECHANICAL
M0.01 DRAWING NOTES AND SYMBOL SCHEDULE
M0.02 MECHANICAL SCHEDULES
M0.03 HVAC ROOF PLAN
M0.04 HVAC LEVEL 1 PLAN
M0.05 HVAC BASEMENT PLAN
M1.01 HVAC WILLOW ROOM RENOVATION PLAN
M1.02 HVAC MAPLE ROOM RENOVATION PLAN
M1.03 HVAC KITCHEN AREA RENOVATION PLAN
M1.04 HVAC SPRUCE ROOM RENOVATION PLAN
M1.05 HVAC OFFICE AREA RENOVATION PLAN
M1.06 HVAC ROOF NORTH RENOVATION PLAN
M1.07 HVAC ROOF SOUTH RENOVATION PLAN
M1.08 HVAC CEDAR, ARBUTUS & BIRCH PLAN
M2.01 MECHANICAL DETAILS
M3.01 MECHANICAL SPECIFICATION
ELECTRICAL
ACUMEN ENGINEERING
650-2700 PRODUCTION WAY
BURNABY BC
V5A 4X1
T: 778 328 9138
F: 604.676.9545
CONTACT: Aleksandr Gordeyev
MECHANICAL
AME GROUP
CONSULTANT MECHANICAL ENGINEERS
1100-808 WEST HASTINGS STREET
VANCOUVER BC
V6C 2X4
T: 604 684 5995
F: 604.684.5993
CONTACT: Andrew Miltimore
ARCHITECTURAL
A000 COVER SHEET, LOCATION PLAN,
DRAWING LIST
A100 NOTES AND WALL PENETRATION
DETAILS
A101 BASEMENT - FLOOR PLANS -
WILLOW, DARTS, MAPLE
(BILLIARDS) ROOMS
A102 LEVEL 1 - FLOOR PLAN
A103 ROOF PLAN
A104 BASEMENT- PARTIAL FLOOR PLAN
- WILLOW, DARTS, MAPLE
(BILLIARDS) ROOMS
A105 LEVEL 1 - PARTIAL FLOOR PLANS -
CEDAR AND SPRUCE ROOMS
A106 LEVEL 1 - PARTIAL FLOOR PLANS -
KITCHEN/ COOLER/ STORAGE/
ELECTRICAL, MANAGER'S/
PROGRAMMER'S/ PEER
COUNSEL'S OFFICES
A107 ROOF-PARTIAL PLANS -
STORAGE/ CEDAR ROOMS AND
LOUNGE AREA
DRAWING LIST
NOTE: THIS IS NOT AN EXHAUSTIVE LIST. IF IN DOUBT, CONTACT THE CONSULTANT FOR CLARIFICATION
ARCH ARCHITECTURAL
PLAM PLASTIC LAMINATE
ALT ALTERNATE
ALUM ALUMINUM
FIN FINISH OR FINISHED
POLY POLY VAPOUR BARRIER
ANOD ANODIZED
PREFIN PREFINISHED
PT PRESSURE TREATED
BLDG BUILDING
PNTD PAINTED
BLK BLOCK
GALV GALVANIZED
REINF REINFORCED, REINFORCEMENT
GWB GYPSUM WALLBOARD
REQ'D REQUIRED
CONC CONCRETE
HC HANDICAPPED
RO ROUGH OPENING
CONT CONTINUOUS
COORD COORDINATE (WITH)
HORIZ HORIZONTAL
SIM SIMILAR
SPEC SPECIFICATION
COL COLUMN
INT INTERIOR
C/W COMPLETE WITH
STRUCT STRUCTURAL
DBL DOUBLE
MAX MAXIMUM
MECH MECHANICAL
THK THICK
DTL DETAIL
DWG DRAWING
MIN
TYP TYPICAL
EA EACH
MTL METAL
U/G UNDERGROUND
UNO UNLESS NOTED OTHERWISE
NTS NOT TO SCALE
U/S UNDERSIDE
VB VAPOUR BARRIER
ELEC ELECTRICAL
OC ON CENTRE
VERT VERTICAL
O/H OVERHEAD
WDW WINDOW
WP WATERPROOF(ING)
EXIST EXISTING
BLKG BLOCKING
CAULK CAULKING LA LIQUID APPLIED
MEMB MEMBRANE
MINIMUM
PLY PLYWOOD
SHEATH SHEATHING
SEAL SEALANT
ELEV DRAWING ELEVATION
PNT PAINT
INSUL INSULATION
FIN FLR FINISHED FLOOR
BP BUILDING PAPER
NOTE: THIS IS NOT AN EXHAUSTIVE LIST. IF IN DOUBT, CONTACT THE CONSULTANT FOR CLARIFICATION
VR VAPOUR RETARDER
LIST OF ABBREVIATIONS
ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION
PERIM PERIMETER
EXT EXTERIOR
P&S PEEL & STICK
REMOVE AND REINSTALL EXISTING
BRICK CLADDING AND MAKE GOOD
SURROUNDING AREA
BUILDING PAPER OVER
FLASHING
LIQUID APPLIED
WATER PROOFING TO
EXTEND DOWN 6"
OVER WOOD
SHEATHING RO LINER
NEW GALVANIZED
PANEL TRIM
NEW SPRAYED ON (CLOSED
CELL) INSULATION
EXIST WALL ASSEMBLY
NEW MECH VENT
NEW 2X BLOCKING
LIQUID APPLIED WATER
PROOFING ON WOOD
SHEATHING
& SEAL TO PREFIN MTL
HEAD FLASH
SCALE:
1
A100
3/32" = 1'-0"
TYP. WALL PENETRATION - BRICK CLADDING
RE
MO
VE
S
UF
FIC
IE
NT
D
RY
W
ALL
TO
A
LLO
W F
OR
IN
ST
ALLA
TIO
N O
F
BLO
CK
IN
G A
ND
C
LO
SU
RE
S.
PA
TC
H/ R
EP
AIR
T
O M
AT
CH
E
XIS
TIN
G
RE
MO
VE
+ R
EIN
ST
ALL S
UF
FIC
IE
NT
BR
IC
K C
LA
DD
IN
G T
O A
LLO
W F
OR
CLO
SU
RE
S. P
AT
CH
/ R
EP
AIR
TO
M
AT
CH
E
XIS
TIN
G
NOTE: FOR 1HR FRR WALLS
OPENING MUST BE BOXED IN WITH
5/8" TYPE X GWB.
PROVIDE FIRE STOPPING AT
PENETRATIONS
General Notes
1. This drawing is prepared from archival information and
from limited site review. Actual conditions may vary. The
contractor shall verify site conditions and dimensions prior
to start of construction. The contractor shall report any
variations that affect the scope or setting out of the work
and obtain direction from the consultants.
2. Patch and Make good all existing finish where affected
by new work.
3. Drawings to be read in conjunction with mechanical,
electrical and structural drawings.
4. Remove and reinstall existing CCTV camera, lighting
equipments and fire exit signs needed to complete work.
NOTE:
FOR 1HR FRR WALLS
OPENING MUST BE BOXED IN WITH 5/8" TYPE X GWB.
PROVIDE FIRE STOPPING AT PENETRATIONS
5. Where an existing surface material is re-instated to match theexisting material, refinish the entire wall and/ or ceiling surfacesto match existing finish and colour.
6. All roofing, patching, penetrations and tie-ins are to becompleted by a RCABC approved contractor.
PROVIDE NEW VENTILATOR
LOUVRE PER MECHANICAL
SEAL TOP EDGE OF
SHEATHING PAPER
LIQUID APPLIED WATER
PROOFING ON WOOD
SHEATHING
EXIST POLY VB
SEAL NEW POLY VB TO
EXIST POLY VB
EXIST WALL ASSEMBLY
REMOVE SUFFICIENT
WOOD SIDING IN AREA
AFFECTED TO ALLOW
CLOSURES, PATCH
AND REPAIR TO MATCH
EXISTING ADJACENT
FINISH
AB SHEATH PAPER LAP
& SEAL TO PREFIN MTL
HEAD FLASH
NEW PLY BLOCKING AS
REQUIRED
LIQUID APPLIED
WATER PROOFING
ON WOOD
SHEATHING
PREFIN MTL SILL
FLASH C/W 1" END
DAM
CUT BACK EXIST GWB
AND MAKE GOOD,
PROVIDE NEW GWB
TO MATCH EXIST,
EXIST WALL ASSEMBLY
LIQUID APPLIED WATER
PROOFING ON WOOD
SHEATHING ON
3/8" X 4" PT PLY SPACER
EX
IS
T W
AL
L A
SS
EM
BL
Y
SEAL NEW POLY VB TO
FRAMING & AB SHEATH
FOR AB CONTINUITY
FILLET CAULK
REMOVE/ CUT AND
RE-INSTALL WALL
FINISHES IN AREA
AFFECTED (MATCH
ADJACENT FINISH)
SCALE:
2
A100
3/32" = 1'-0"
TYP. WALL PENETRATION - WOOD CLADDING
HEAD SILL JAMB
L-1
24"X12"
L-1
24"X12"
REMOVE SUFFICIENT DRY WALL
TO ALLOW FOR INSTALLATION OF
BLOCKING AND CLOSURES.
PROVIDE NEW GWB, PATCH
AND REPAIR TO MATCH ADJACENT
EXISTING
3/8" ROD & CAULK
FIRE DAMPER
MECHANICAL
DUCT
FIRE DAMPER
MECHANICAL
DUCT
PREFIN MTL HEAD FLASH
C/W 1" END DAM
MECHANICAL
DUCT
REMOVE/ CUT AND RE-INSTALL
WALL FINISHES IN AREA
AFFECTED (MATCH ADJACENT
FINISH)
3/4"X 3" CEDAR WOOD
TRIM, PAINT TO MATCH
ADJACENT TRIM
COLOUR
REMOVE AND REINSTALL EXIST
STUCCO AND MAKE GOOD
SURROUNDING AREA
LIQUID APPLIED WP ON WOOD SHEATHING
LIQUID APPLIED
WATER PROOFING ON
WOOD SHEATHING
NEW GALVANIZED
METAL
NEW SPRAYED ON (CLOSED
CELL) INSULATION
EXIST WALL ASSEMBLY
NEW MECH VENT
NEW 2X BLOCKING
LIQUID APPLIED WATER
PROOFING ON WOOD
SHEATHING
SCALE:
3
A100
N.T.S.
TYP. WALL PENETRATION - STUCCO CLADDING
RE
MO
VE
S
UF
FIC
IE
NT
D
RY
W
ALL
TO
A
LLO
W F
OR
IN
ST
ALLA
TIO
N O
F
BLO
CK
IN
G A
ND
C
LO
SU
RE
S. P
AT
CH
AN
D R
EP
AIR
T
O M
AT
CH
A
DJA
CE
NT
EX
IS
TIN
G A
S N
EE
DE
D
RE
MO
VE
S
UF
FIC
IE
NT
S
TU
CC
O
TO
A
LLO
W F
OR
C
LO
SU
RE
S.
PA
TC
H A
ND
R
EP
AIR
T
O M
AT
CH
E
XIS
TIN
G
KEYED STUCCO JOINT
PREFIN MTL HEAD
FLASH C/W 1" END DAM, TYP.
1"
Revision
1 20 Mar 2019 Issued for Review for Tender
2 25 Mar 2019 Issued for Tender
I:\PROJECTS\Year 2019\19028 - New West City - Century House AC system addition-archKJ\DWGS\Phase 6 Bidding\19128-6-A-Century House-AC Sys Add.dwg
220 - 12 Water Street
Vancouver, BC V6B 1A5
604 - 736 - 5581
IREDALE
A R C H I T E C T U R E
Vancouver Victoria
iredale.ca
CENTURY HOUSE
AC SYSTEM ADDITION
620 EIGHTH STREET,
NEW WESTMINSTER, BC
SA BL KBJ
19028
25 MAR 2019 6
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
Definitions:
1."making good" and/or "make good" shall be defined as preparing new surfaces which are identical to adjacent surfaces (with similar
backing materials), and finished off in such a manner that there are absolutely no visible traces (at a distance of 600mm / 2 feet)
between existing work and the work of new patching. "making good" therefore, extends to the complete re-finishing of entire surface
areas as is necessary, to junction points or inside or outside corners of walls, partitions and ceilings.
2. "making good" for painting refers to satisfactorily preparing finish surfaces for paint, so that newly patched surfaces are
indistinguishable from immediately adjacent existing finishes of similar materials.
3. "patch and paint" for painting shall mean "make good".
4. "re & re" shall mean, remove, safely store and reinstall in a proper functional condition. Make good areas affected by this work.
NOTES AND
WALL PENETRATION
DETAILS
3/32" = 1'-0"
A100
B DC EA F LG H J K
2
1
3
5
4
6
7
8
9
10
11
12
UP
CRAWL SPACE
STAIR#1
STAIR#2
CORR. ELECT.
B02
STORAGE
PARK ATTNDT.
WOMENS
CORR.
MENS
WEIGHT ROOM
MAPLE ROOM (BILLIARDS)
STORAGE ROOM
POTTERY
ELEV.
STORAGE ROOM
DARTS ROOM
LAUNDRY
FURNACE ROOM
KILN
MULTI-PURPOSE
DAMP STORAGE
WILLOW ROOM
STORAGE ROOM
CRAWL SPACE
W/C
CLG. HT.
7'-7"
CLG. HT.
7'-2"
CLG. HT.
6'-8"
CLG. HT.
7'-8"
CLG. HT.
7'-8"
CLG
. H
T.
6'-11 3/4"
CLG. HT.
6'-8"
CLG. HT.
7'-4 1/2"
CLG. HT.
7'-4 1/2"
CLG. HT.
7'-7 1/2"
CLG. HT.
7'-9 1/2"
EXIST. TRACK LIGHTING
EXIST. BULKHEAD
SCALE:
1
A101
3/32" = 1'-0"
BASEMENT FLOOR PLAN
RF
GR
RF
GS
RF
GR
RF
GS
C
C
RF
GR
RF
GS
C
EQ. EQ.
EQ. EQ.
RF
GR
RF
GS
RF
GR
RF
GS
C
RFGR
RFGS
C
X
4X
X
X X
1 TON
1-1/2 T
ON
1-1/2 T
ON
64"
38"
1
A104
2
A104
CU-5
CU-4
64"
38"
EXIST.PNL 'X'
EXIST.PNL 'A'
SCALE:
B
A101
NTS
BILLIARDS ROOM
SCALE:
A
A101
NTS
CRAWL SPACE OUTSIDE WILLOW RM.
A
A101
B
A101
Revision
1 20 Mar 2019 Issued for Review for Tender
2 25 Mar 2019 Issued for Tender
I:\PROJECTS\Year 2019\19028 - New West City - Century House AC system addition-archKJ\DWGS\Phase 6 Bidding\19128-6-A-Century House-AC Sys Add.dwg
220 - 12 Water Street
Vancouver, BC V6B 1A5
604 - 736 - 5581
IREDALE
A R C H I T E C T U R E
Vancouver Victoria
iredale.ca
CENTURY HOUSE
AC SYSTEM ADDITION
620 EIGHTH STREET,
NEW WESTMINSTER, BC
SA BL KBJ
19028
25 MAR 2019 6
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
BASEMENT
FLOOR PLANS - WILLOW,
DARTS, MAPLE
(BILLIARDS) ROOMS
3/32" = 1'-0"
A101
N
DCBA E F G H J K L
1
2
3
4
5
6
7
8
9
10
11
12
OPEN TO BELOW
YOUTH
OFFICE
YOUTH
OFFICE
EXISTING FOYER
KITCHEN
MENS WOMENS
UPPER LOUNGE
FLEX OFFICE
LOUNGE
RECEPTION
JANITOR
CORR.
CO
RR
.
COMPUTER/STUDY
MANAGER
FLEX OFFICE
RA
MP
D
N
ENTRY
ELECT.STORAGE
OFFICE
COOLER
KITCHEN
WOMENS
MENS
LOUNGE
FIR ROOM
DOUGLAS ROOM
STORAGE
CEDAR ROOM
BIRCH ROOM
ARBUTUS ROOM
SPRUCE ROOM
OFFICE/RECEPTION
MANAGER
PROGRAMMER
SENIOR PEER COUN.
ELEVATOR
BARRIER-FREE W/C
STORAGE
JANITOR
STORAGE
RA
MP
U
P
DECK
WOMENS
MENS
STORAGE
STORAGE
OAK ROOM
CLG. HT.
8'-0"
CLG. HT.
7'-3"
CLG. HT.
8'-0"
CLG. HT.
8'-0"
CLG. HT.
8'-0"
CLG. HT.
7'-9"
CLG. HT.
7'-11"
CLG. HT.
8'-0"
CLG. HT.
8'-0"
CLG. HT.
8'-0"
EXIST.
BULKHEAD
CLG. HT.
9'-8"
CLG. HT.
7'-8"
CLG. HT.
7'-10"
FREEZER
EXIST. WINDOW BULKHEAD
HWT
OVEN
CLG. HT.
7'-10"
SCALE:
1
A102
3/32" = 1'-0"
LEVEL 1 FLOOR PLAN
C
RF
GS
RF
GR
EXISTING BB
HEATER
EXISTING BB
HEATER
EXISTING BB
HEATER
1/2 TON
1/2 TON
1/2 TON
AC
LIN
E R
OU
TIN
G
EXISTING BASEBOARD
EX
IS
TIN
G B
AS
EB
OA
RD
EXISTING BASEBOARD
1"
C
RF
GR
RF
GS
FIRE DAMPER
SEE DETAIL 4/M2.01
FIRE DAMPER
1
A105
2
A105
CU-2
CU-1
2
A106
CU-3
1
A106
5'-2"
5'
EXT R
EXIST. PNL 'Z'
APPROX. LOCATION OFEXISTING ELEC. ROOM(B13) IN BASEMENT
J
EXIST. PNL 'B'
EXIST. PNL 'W'EXIST. PNL 'W'
J
J
C
A102
SCALE:
C
A102
NTS
CEDAR AND BIRCH ROOM
M
A102
SCALE:
M
A102
NTS
SPRUCE ROOM - EXTERIOR
SCALE:
D
A102
NTS
ARBUTUS ROOM
SCALE:
F
A102
NTS
ELECTRICAL ROOM
SCALE:
K
A102
NTS
MANAGER'Ss ROOM
SCALE:
H
A102
NTS
PEER COUNSEL's ROOM
SCALE:
J
A102
NTS
PROGRAMMER's ROOM
SCALE:
L
A102
NTS
SPRUCE ROOM - WINDOW SIDE
L
A102
D
A102
SCALE:
E
A102
NTS
RAMP TO KITCHEN
6'-1"
VE
RIF
Y W
/ M
EC
HA
NIC
AL
7'-4"
VERIFY W/ MECHANICAL
4"
78"
36"
SCALE:
G
A102
NTS
REMOVE FORCED FLOW HEATER
NOTE:
PATCH/ REPAIR OPENING AFTER REMOVAL OF
FORCE FLOW HEATER AND ADD GWB, AS
NEEDED, PATCH AND FINISH WITH PAINT TO
MATCH ADJACENT, AS PER OWNER
18"±
6"
DRAWING LEGEND:
AREA NOT IN SCOPE OF WORK
DEMOLISH OR REMOVE EXISTING
1. ALL EXISTING SURFACES AFFECTED BY THE WORK TO BE
PREPARED FOR RE-PAINTING IN ACCORDANCE WITH MPI
STANDARDS.
2. ALL LABOUR, MATERIALS AND PRODUCTS TO COMPLY WITH
THE REQUIREMENTS OF THE BC BUILDING CODE, 2012 EDITION,
AND ALL OTHER APPLICABLE CODES, STANDARDS AND
BYLAWS.
3. PATCH AND REPAIR AND FINISH TO MATCH ADJACENT FINISHES
IN AREAS AFFECTED.
4. MUST COORDINATE WITH MECHANICAL AND ELECTRICAL. AS
REQUIRED
GENERAL NOTES
GENERAL DEMOLITION NOTES
1. ALL DIMENSIONS TO BE CONFIRMED ON SITE PRIOR TO ANY
EXECUTION OF WORK.
2. GC TO ALLOW FOR RELOCATION OF ACCESSORIES,
APPLIANCES, EQUIPMENT, GARBAGE BINS, ETC. AS
REQUIRED BY SCOPE OF WORK, TYP.
3. PATCH AND MAKE GOOD EXISTING WALLS/ COLUMNS AND
ALL AREAS AFFECTED BY WORK.
4. COORDINATE LOCATION OF STRUCTURE PRIOR TO ANY
WORK.
NEW L-1, LOUVRE
PER MECHANICAL
HEAD FLASHING,
SEE DETAIL 2/A100
EXISTING LOUVRE
SILL FLASHING,
SEE DETAIL 2/A100
EXIST. WOOD TRIM
SCALE:
1
A102
1/8" = 1'-0"
PARTIAL ELEVATION - LOUVRE [L-1] - SPRUCE ROOM
Revision
1 20 Mar 2019 Issued for Review for Tender
2 25 Mar 2019 Issued for Tender
I:\PROJECTS\Year 2019\19028 - New West City - Century House AC system addition-archKJ\DWGS\Phase 6 Bidding\19128-6-A-Century House-AC Sys Add.dwg
220 - 12 Water Street
Vancouver, BC V6B 1A5
604 - 736 - 5581
IREDALE
A R C H I T E C T U R E
Vancouver Victoria
iredale.ca
CENTURY HOUSE
AC SYSTEM ADDITION
620 EIGHTH STREET,
NEW WESTMINSTER, BC
SA BL KBJ
19028
25 MAR 2019 6
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
N
LEVEL 1
PARTIAL FLOOR PLAN
3/32" = 1'-0"
A102
B13 ELEC.
EXISTINGCU UNITYOUTHCENTRE
APPROX. LOCATION OF EXISTINGELEC. ROOM B13 IN BASEMENT
APPROX. LOCATION OF 5" DIA.PIPE PENETRATION FORELECTRICAL CONDUITS, REFERTO DETAIL 3/A107
DC E F G H J K L
1
2
3
4
5
6
7
8
9
10
11
12
BA
SCALE:
1
A103
3/32" = 1'-0"
ROOF PLAN
HV-1
HV-2
HV-3
1
A107
2
A107
EXISTING PARKS BUILDING
GENSET
ELECT.
GAS METERS
Revision
1 20 Mar 2019 Issued for Review for Tender
2 25 Mar 2019 Issued for Tender
I:\PROJECTS\Year 2019\19028 - New West City - Century House AC system addition-archKJ\DWGS\Phase 6 Bidding\19128-6-A-Century House-AC Sys Add.dwg
220 - 12 Water Street
Vancouver, BC V6B 1A5
604 - 736 - 5581
IREDALE
A R C H I T E C T U R E
Vancouver Victoria
iredale.ca
CENTURY HOUSE
AC SYSTEM ADDITION
620 EIGHTH STREET,
NEW WESTMINSTER, BC
SA BL KBJ
19028
25 MAR 2019 6
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
ROOF PLAN
3/32" = 1'-0"
A103
N
MAPLE ROOM (BILLIARDS)
DARTS ROOM
STORAGE ROOM
CLG. HT.
6'-8"
CLG. HT.
7'-8"
CLG. HT.
7'-8"
CLG
. H
T.
6'-1
1 3
/4
"
CLG. HT.
6'-8"
CLG. HT.
7'-4 1/2"
CLG. HT.
7'-4 1/2"
CU-5
RF
GR
RF
GS
RF
GR
RF
GS
C
RFGR
RFGS
C
AC-7
AC-6
AC-8
ALL REFRIGERANT, CONDENSATE,
POWER AND CONTROL LINES ARE
TO RUN INSIDE BULK HEAD TIGHT
TO UNDERSIDE OF CEILING
X
4X
X
X X
6'-0" HIGH CHAIN-LINK
FENCE WITH
LOCKABLE GATE
1 TON
1-1
/2
T
ON
1-1
/2
T
ON
EXISTING BASEBOARD HEATER
6" CONCRETE
PAD
64"
38"
EXIST.PNL 'A'
NEW BULKHEAD - 12" DEEP X 7 3/4" WIDE, AS
TIGHT AS NEEDED FOR MECHANICAL /
ELECTRICAL, CONFIRM WITH ARCHITECT,
PATCH / REPAIR/ PAINT AS NEEDED
NEW WALL PENETRATIONS 8"X8" PER DETAIL3/A100 (SIM.), GC TO CONFIRM PENETRATIONTHRU. CONC. WALL OR WOOD FRAME.COORDINATE WITH MECH/ ELEC. CONDUITS TO
AC UNITS CLG. MTD., TO BE VERIFIED ON SITE
NEW BULKHEAD - 16" DEEP X 7 3/4"
WIDE, AS TIGHT AS NEEDED FOR
MECHANICAL / ELECTRICAL, CONFIRM
WITH ARCHITECT
4
A105
3
A104
3
A104
SIM.
SIM.
7 3/4"
BULKHEAD
7 3
/4
"
BU
LK
HE
AD
NEW WALL PENETRATIONS 4"X4" PER DETAIL3/A100 (SIM.), GC TO CONFIRM PENETRATIONTHRU. CONC. WALL OR WOOD FRAME.COORDINATE WITH MECH/ ELEC. CONDUITS TO
AC UNITS CLG. MTD., TO BE VERIFIED ON SITE
NOTE: HOLES IN CONCRETE WALLS
MIN. 1" DIA. LARGER THAN
INSULATED PIPES
NOTE: LOCATE FENCE MIN. 3'-0"
CLEAR OF MECHANICAL EQUIPMENT.
PROVIDE 3'-0" WIDE FENCE GATE.
18'-11"
43
'-1
0"
STAIR#2
WILLOW ROOM
W/C
CLG. HT.
7'-7"
CLG. HT.
7'-2"
CLG. HT.
7'-9 1/2"
EXIST. TRACK LIGHTING
EXIST. BULKHEAD
CU-4
RF
GR
RF
GS
RF
GR
RF
GS
C
AC-9 AC-10
C
RF
GR
RF
GS
C
AC-11
6" CONCRETE
PAD
NEW WALL PENETRATION
4"X4" PER MECHANICAL /
ELECTRICAL CONDUITS TO
AC UNITS CLG. MTD., TO BE
COORDINATED ON SITE
PROVIDE/ INSTALL
NEW 6'-0" HIGH CHAIN-LINK
FENCE WITH LOCKABLE
GATE
EQ. EQ.
EQ. EQ.
64"
38"
NEW BULKHEAD - 12" DEEP X 7 3/4" WIDE, AS
TIGHT AS NEEDED FOR MECHANICAL /
ELECTRICAL, CONFIRM WITH ARCHITECT
7"
NEW WALL PENETRATION
4"X4" PER MECHANICAL /
ELECTRICAL CONDUITS TO AC UNITS
WALL MTD., COORDINATE ON SITE
NEW 22 ga PREFINISHED
METAL FLASHING BREAK
SHAPE TO HOUSE
MECHANICAL / ELECTRICAL
CONDUITS
4
A104
3
A104
SIM.
4
A104
EX
IS
TIN
G B
ULK
HE
AD
36'-4 1/4"
17'-1"
7 3/4"
4
A104
SIM.
NOTE: ALL MECHANICAL LINES/
ELECTRICAL CONDUITS TO BE
LOCATED ON EXTERIOR WALL
NOTE: HOLES IN CONCRETE WALLS
MIN. 1" DIA. LARGER THAN
INSULATED PIPES
NOTE: LOCATE FENCE MIN. 3'-0"
CLEAR OF MECHANICAL EQUIPMENT.
PROVIDE 3'-0" WIDE FENCE GATE.
4
A105
4"
CLR.
7'-0" M
IN
. C
LE
AR
AN
CE
,
GC
T
O C
ON
FIR
M O
N S
IT
E
EXISTING
EXISTING
NEW AC UNIT (TYP.) WALL MTD. PER
MECH. DWGS. BULKHEAD TO HOUSE
ALL ELECTRICAL CONDUITS , MECH.
AS TIGHT AS POSSIBLE TO CEILING.
GC TO CONFIRM ON SITE BEFORE
INSTALLING AC UNIT C/W BULKEAD
12"
CLR.
WRAP TIGHT WITH
1
2
"
GYPSUM BOARD
EXISTING CEILING
7 3/4"
22ga PRE-FINISHED METAL
FLASHING BRAKE SHAPE
SHROUD TO BE MIN 12"H
AND COVER PIPES
COMPLETELY, CONFIRM
SIZE WITH MECH/ ELEC.
MECH.
PIPING/
ELEC.
CONDUITS
INSTALL NEW AC UNIT
(TYP.) WALL MTD. PER
MECH. DWGS. WITH
CLEARANCES PER MECH.
SPECS.
GC TO CONFIRM ON SITE
BEFORE INSTALLING
RE & RE WOOD CLADDING
AS NEEDED TO INSTALL
METAL ENCLOSURE TO
RUN CONDUITS THROUGH
WALL PENETRATION TO
AC UNIT, WALL MOUNTED
AS LOCATED PER MECH.
DWGS. AS TIGHT AS
POSSIBLE.
GC TO CONFIRM WITH
MECH.ON SITE BEFORE
INSTALLING
1
2
" CAULK ALL AROUND (TYP)
4"
CLR.
12"±
6"
CLR.
12"
CLR.
4"X4" WALL
PENETRATION
PER MECH.
DWGS.
CUT / REPAIR OPENING,
TO BE REINFORCED PER
STRUCTURAL
1"
1"
FASTEN SHROUD TO
CONCRETE WITH BOLTS
WITH 1"+ OVERLAP
Revision
1 20 Mar 2019 Issued for Review for Tender
2 25 Mar 2019 Issued for Tender
I:\PROJECTS\Year 2019\19028 - New West City - Century House AC system addition-archKJ\DWGS\Phase 6 Bidding\19128-6-A-Century House-AC Sys Add.dwg
220 - 12 Water Street
Vancouver, BC V6B 1A5
604 - 736 - 5581
IREDALE
A R C H I T E C T U R E
Vancouver Victoria
iredale.ca
CENTURY HOUSE
AC SYSTEM ADDITION
620 EIGHTH STREET,
NEW WESTMINSTER, BC
SA BL KBJ
19028
25 MAR 2019 6
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
N
SCALE:
2
A104
1/4" = 1'-0"
PARTIAL FLOOR PLANS - WILLOW ROOM
SCALE:
1
A104
1'-0" = 1/4"
PARTIAL FLOOR PLANS - DARTS, MAPLE (BILLIARDS) ROOMS
SCALE:
3
A104
N.T.S.
TYP. BULKHEAD DETAIL - WILLOW/ MAPLE Rooms
BASEMENT
FLOOR PLANS - WILLOW,
DARTS, MAPLE
(BILLIARDS) ROOMS
3/32" = 1'-0"
A104
SCALE:
4
A104
N.T.S.
METAL ENCLOSURE SECTION/ WALL PENE.- WILLOW Rm.
CEDAR ROOM
BIRCH ROOM
ARBUTUS ROOM
JANITOR
DECK
EXISTING
BASEBOARD
HEATER
EXISTING
BASEBOARD
HEATER
EXISTING
BASEBOARD
HEATER
3
A105
REMOVE AC UNIT/ WINDOW
SHAKER, PATCH & REPAIR
INSTALL NEW GLAZING TO
MATCH ADJACENT
GLAZING TO BE TINTED,
TYPICAL, VERIFY WITH OWNER
GLAZING TO BE TINTED,
TYPICAL, VERIFY WITH OWNER
REMOVE AC UNIT/ WINDOW
SHAKER, PATCH & REPAIR
INSTALL NEW GLAZING TO
MATCH ADJACENT
CORR.
LOUNGE
SPRUCE ROOM
CLG. HT.
9'-8"
CLG. HT.
7'-8"
CLG. HT.
7'-10"
EXIST. WINDOW BULKHEAD
CLG. HT.
7'-10"
R-1
L-1
S-1 S-1
S-1
C
RF
GS
RF
GR
DRAIN AC-7 CONDENSATE TO SINK
UPSTREAM OF P-TRAP, RUN THE PIPING UP
THE WALL, THROUGH THE SOFFIT INTO THE
ATTIC SPACE.REFER TO MECHANICAL DWGS.
COORDINATE
FINAL LOCATION
ON SITE
ALL OUTDOOR REFRIGERANT,
POWER AND CONTROL LINES
ARE TO RUN INSIDE FURRED
OUT PORTION OF EXTERIOR
WALL; INSIDE LINES ARE TO
RUN WITHIN CEILING PLENUM
AC-5
SUPPLY
INTAKE
CU-3
EXISTING BB
HEATER
EXISTING BB
HEATER
EXISTING BB
HEATER
PROVIDE NEW 6"
CONCRETE PAD
EXISTING
ACCESS
HATCH
16"±.
CUT OPEN GWB, AS NEEDED, PATCH/ REPAIR/
PAINT. REMOVE ACCESSORIES ON WALL AND
RE-INSTALL AFTER PATCH/ REPAIR AND
PAINTING - WALL FROM CORNER TO CORNER
AND FLOOR TO CLG.
ADD
3
4
" PLYWOOD C/W
SUPPORT FOR AC-5.
EXTEND PLYWOOD
C/W SUPPORTS
AROUND AC-5 FOR
SERVICING
EXTEND
PLYWOOD
PLATFORM
TO HATCH
5'-2"
5'
EXIST. PNL 'Z'
NEW WALL PENETRATION PER
MECHANICAL / ELECTRICAL
CONDUITS TO AC UNITS CLG. MTD.,
TO BE COORDINATED ON SITE
TO BE COVERED WITH 22 ga
PREFINISHED SHEET METAL
ENCLOSURE ON EXTERIOR
SIDE(3"X6") SITE VERIFY, SEE
DETAIL 4/A106
NEW WALL PENETRATION
(24"X12") PER MECHANICAL, TO
BE COORDINATED ON SITE.
SEE ARCH. DETAIL 2/A100
6'-1
"
VE
RIF
Y W
/ M
EC
HA
NIC
AL
7'-4"
VERIFY W/ MECHANICAL
2
A100
CUT OPENINGS FOR NEW
MECHANICAL DIFFUSERS,
PER MECHANICAL
CUT OPENINGS FOR NEW
MECHANICAL DIFFUSERS,
PER MECHANICAL
NOTE: LOCATE FENCE MIN. 3'-0"
CLEAR OF MECHANICAL EQUIPMENT.
PROVIDE 3'-0" WIDE FENCE GATE.
4
A105
2'-0"
2'-0 1/2"
10'-7"
SITE VERIFY
7'-2"
SITE VERIFY
BASE BOARD HEATER
REMOVE AC UNIT C/W
PLYWOOD, PATCH & REPAIR
INSTALL NEW GLAZING TO
MATCH ADJACENT
BASE BOARD HEATER BASE BOARD HEATER
REMOVE AC UNIT C/W PLYWOOD,
PATCH & REPAIR INSTALL NEW
GLAZING TO MATCH ADJACENT
3'-4"
SITE VERIFY
3'-4"
SITE VERIFY
2'-6"
GLAZING TO BE TINTED/
WITH FILM, TYPICAL, TO
BE CONSISTENT
GLAZING TO BE TINTED/
WITH PURPLE FILM TO
MATCH ADJACENT,
TYPICAL, TO BE
CONSISTENT
EXIST.
PURPLE FILM
EXIST. PURPLE FILM EXIST.
PURPLE FILM
EXIST.
PURPLE
FILM
5'-4"
NO FILMNO FILM NO FILM NO FILM NO FILM
NO FILMNO FILM
8'-6"
CEILING
FINISH FLOOR
NO FILM NO FILM
4
A105
CU-2
PAD MOUNTED ON
DURA-BLOCK
CONCRETE
PAD
5'-4"
3'-2"
1'-0"
1'-0"
1'-0"
1'-0"
CU-3
CU-4
CU-5
TYP. CONC SLAB DETAIL
1/2" = 1'-0"
3
A104
6"
COMPACTED SAND
OR PROVIDE 3/4" FREE DRAINING
GRAVEL; 95% PROCTOR
2X6 PT BLOCKING ON STAKE
SOFTEN ALL EDGES
GRADE LEVEL
TYP. CONC SLAB SECTION
1/2" = 1'-0"
4
A104
INSTALLATION NOTES:
1. FOR AIR CONDITIONING EQUIPMENT CONCRETE SLABS ON GRADE,
PROVIDE, 6" GALVANIZED STEEL MESH REINFORCED CONCRETE SLAB,
6" GRAVEL FILL COMPACTED TO 95% DENSITY OVER COMPACTED SUB
BASE. ALL EXCAVATION TO BE COMPLETED BY HAND, UNDER
SUPERVISION OF THE CITY ARBORIST, AS REQUIRED BY CITY OF NEW
WESTMINSTER.
2. CONCRETE TO BE 30 MPa MIN.
Revision
1 20 Mar 2019 Issued for Review for Tender
2 25 Mar 2019 Issued for Tender
I:\PROJECTS\Year 2019\19028 - New West City - Century House AC system addition-archKJ\DWGS\Phase 6 Bidding\19128-6-A-Century House-AC Sys Add.dwg
220 - 12 Water Street
Vancouver, BC V6B 1A5
604 - 736 - 5581
IREDALE
A R C H I T E C T U R E
Vancouver Victoria
iredale.ca
CENTURY HOUSE
AC SYSTEM ADDITION
620 EIGHTH STREET,
NEW WESTMINSTER, BC
SA BL KBJ
19028
25 MAR 2019 6
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
SCALE:
2
A105
1/4" = 1'-0"
PARTIAL FLOOR PLAN - SPRUCE
SCALE:
1
A105
1/4" = 1'-0"
PARTIAL FLOOR PLAN - CEDAR
SCALE:
3
A105
1/4" = 1'-0"
PARTIAL ELEVATION - GLAZING REPLACEMENT- CEDAR/ BIRCH ARBUTUS RMS.
LEVEL 1
PARTIAL FLOOR PLANS -
CEDAR AND SPRUCE ROOMS
1/4" = 1'-0"
A105
N
ENTRY
OFFICE/RECEPTION
MANAGER
PROGRAMMER
SENIOR PEER COUN.
RA
MP
U
P
CLG. HT.
8'-0"
CLG. HT.
8'-0"
CLG. HT.
8'-0"
CLG. HT.
8'-0"
HRV-1 (A)
AC-1
HRV-2 (A)
HRV-3 (A)
FF-1
HRV-2 (B)
HRV-1 (B)
HRV-3 (B)
CEILING
MOUNTED
PROVIDE 6" CONCRETE
SLAB TO MATCH WIDTH
OF CHIMNEY
PROTRUSION AND
EXTENT OUT TO BE
FLUSH WITH SIDEWALK
1/2 TON
1/2 TON
1/2 TON
AC
LIN
E R
OU
TIN
G
EXISTING BASEBOARD
EX
IS
TIN
G B
AS
EB
OA
RD
EXISTING BASEBOARD
AC-2
CU-2
AC-3
CONFIRM W/ ELECTRICALCONSULTANT FOR SIZE ANDTYPE OF SURFACE MOUNTRACEWAY WIREMOLD
REMOVE EXISTING ENTRANCE FORCE FLOWHEATER C/W WIRING OVER THE DOUBLE DOORS
ENTERING FROM THE MAIN ENTRY.
INSTALL SURFACE MOUNT RACEWAY WIREMOLDWIRING ON WALL/CEILING AT NEW LOCATION OFFF-1 ABOVE THE ENTRANCE. REFER TOELECTRICAL DRAWINGS.
REMOVE / REINSTALL
EXISTING EXIT SIGN FROM
THE CEILING ABOVE THE
ENTRANCE AT NEW LOCATION
PER ELECTRICAL DWGS.
REFER TO WALL PENETRATIONDETAIL 4/A106, COORDINATEWITH MECH/ ELEC
REFER TO WALL PENETRATIONDETAIL 4/A106, COORDINATEWITH MECH/ ELEC
REFER TO WALL PENETRATIONDETAIL 4/A106, AND PIPE CHASEON EXTERIOR WALL
REFER TO WALL PENETRATION DETAIL4/A106, AND PIPE CHASE ON EXTERIORWALL COORDINATE WITH MECH/ ELEC
REFER TO WALL PENETRATIONDETAIL 4/A106, AND PIPE CHASECOORDINATE WITH MECH/ ELEC
4"
78"
36"
1
A100
TYP.
3
A106
TYP.BULKHEADDETAIL
1
A100
TYP.
INFILL OPENING
REFER TO WALL PENETRATIONDETAIL 1/A100, COORDINATEWITH MECH/ ELEC
2'-0"
3'-0"
8'-10"
3'-3"
24"
2'-2"
24"
1
A100
TYP.
1
A100
TYP.
NOTE: LOCATE FENCE MIN. 3'-0"
CLEAR OF MECHANICAL EQUIPMENT.
PROVIDE 3'-0" WIDE FENCE GATE.
4
A105
18"±
6"
RA
MP
D
N
ELECT.STORAGE
OFFICE
COOLER
KITCHEN
BARRIER-FREE W/C
CLG. HT.
7'-3"
CLG. HT.
7'-9"
CLG. HT.
7'-11"
CLG. HT.
8'-0"
CLG. HT.
8'-0"
CLG. HT.
8'-0"
EXIST.
BULKHEAD
FREEZER
HWT
OVEN
1"
S-1
L-1
AC-4
CU-1
C
RF
GR
RF
GS
WALL MOUNTED
CONDENSING UNIT, C/W
VIBRATION ISOLATION.
INSTALL 1" CLEAR OF
THE RWL
ALL REFRIGERANT,
CONDENSATE, POWER
AND CONTROL LINES
ARE TO RUN INSIDE
BULK HEAD TIGHT TO
UNDERSIDE OF CEILING
EF-1
FIRE DAMPER
SEE DETAIL 4/M2.01
CONTRACTOR TO
FIRESTOP ALL
PENETRATIONS THROUGH
FIRE RATED WALLS C/W
TYPE X GWB.
PAINT ALL NEW WORK
AFFECTED BY NEW DUCT/
INSULATION/ COVERS
WALLS PATCHING AND
MAKE GOOD
TYPICAL NEW WALL
PENETRATION DETAIL,
SEE 4/ A105 (SIM. TO
STUCCO WALL) AND
DETAIL 4/A106, SIM.
FIRE DAMPER
EXIST.
ACCESS
HATCH
SURFACE MOUNTED WIREMOLD TOOUTSIDE UNIT. FINISHED AND PAINTEDTO MATCH ADJACENT WALL COLOURS,GC TO CONFIRMREFER TO ELECTRICAL DRAWINGS.
REFER TO WALL PENETRATIONSECTION 3/A100, AND PLANDETAIL 4/A106 (SIM.)COORDINATE WITH MECH/ ELEC
EXIST. RWL
INSTALL NEW WALL WALL MTD. AC PER
MECHANICAL / ELECTRICAL CONDUITS , TO BE
COORDINATED ON SITE. ADD WIREMOLD AS
NEEDED TO COVER ELEC. AND PAINT TO
MATCH ADJACENT, CONFIRM W/ ARCH.
3
A100
10' (VERIFY W/MECH.)
ROUTE PIPING AROUND
EXISTING LIGHT FIXTURES
PER ELEC./ MECH.
INFILL OPENING
OF REMOVED
FORCE FLOW
HEATER, USE
TYPE 'X' GWB
NEW
BULKHEAD
AS TIGHT AS
POSS.
3
A106
TYP.
6'-0"
9'-2"
6'-5"
5'-6"
8'-8"
NOTE:ALL DIMENSIONS TO BE SITE VERIFIEDWITH EXISTING CONDITIONS IN ALLDRAWINGS
7'-0
" M
IN
. C
LE
AR
AN
CE
,
GC
T
O C
ON
FIR
M O
N S
IT
E
EXISTING
NEW AC UNIT (TYP.) WALL MTD. PER
MECH. DWGS. BULKHEAD TO HOUSE
ALL ELECTRICAL CONDUITS , MECH.
AS TIGHT AS POSSIBLE TO CEILING.
GC TO CONFIRM WITH MECH./ ARCH.
BEFORE INSTALLING BULKEAD
12"
CLR.
WRAP TIGHT WITH
1
2
"
GYPSUM BOARD
EXISTING CEILING
4"
EXISTING
SHROUD TO COVER PIPES
COMPLETELY, CONFIRM
SIZE WITH MECH/ ELEC.
ME
CH
.
PIP
IN
G/
EL
EC
.
CO
ND
UIT
S
RE & RE BRICK/ WOOD/
STUCCO CLADDING AS REQD.
TO INSTALL METAL
ENCLOSURE TO RUN
CONDUITS THROUGH WALL
PENETRATION TO
MECH/ELEC, AS INDICATED
AS TIGHT AS POSSIBLE.
GC TO CONFIRM WITH
MECH.ON SITE BEFORE
INSTALLING
4"-6"
PER
MECH./
ELEC.
6"-12" PER MECH./ELEC.
CLR.
4"X4" WALL
PENETRATION
PER MECH.
DWGS.
CUT / REPAIR OPENING,
TO BE REINFORCED PER
STRUCTURAL
22GA PRE-FINISHED
METAL FLASHING BRAKE
SHAPE
1
2
" CAULK ALL AROUND
(TYP)
FASTEN SHROUD TO
CONCRETE WITH BOLTS
WITH 1"+ OVERLAP
EX
IS
T W
AL
L A
SS
EM
BL
Y
EX
IS
T W
AL
L A
SS
EM
BL
Y
Revision
1 20 Mar 2019 Issued for Review for Tender
2 25 Mar 2019 Issued for Tender
I:\PROJECTS\Year 2019\19028 - New West City - Century House AC system addition-archKJ\DWGS\Phase 6 Bidding\19128-6-A-Century House-AC Sys Add.dwg
220 - 12 Water Street
Vancouver, BC V6B 1A5
604 - 736 - 5581
IREDALE
A R C H I T E C T U R E
Vancouver Victoria
iredale.ca
CENTURY HOUSE
AC SYSTEM ADDITION
620 EIGHTH STREET,
NEW WESTMINSTER, BC
SA BL KBJ
19028
25 MAR 2019 6
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
SCALE:
2
A106
1/4" = 1'-0"
PARTIAL FLOOR PLAN - MANAGER'S/ PROGRAMMER'S/ PEER COUNSEL'S OFFICES
SCALE:
1
A106
1/4" = 1'-0"
PARTIAL FLOOR PLAN - KITCHEN/ COOLER/ STORAGE/ ELECTRICAL
LEVEL 1
PARTIAL FLOOR PLANS -
KITCHEN/ COOLER/ STORAGE/
ELECTRICAL, MANAGER'S/
PROGRAMMER'S/ PEER
COUNSEL'S OFFICES
1/4" = 1'-0"
A106
SCALE:
3
A106
3/32" = 1'-0"
TYP. BULKHEAD DETAIL - OFFICES
N
SCALE:
4
A106
3/32" = 1'-0"
TYP. METAL ENCLOS. PLAN DETAIL - EXTERIOR
HV-1
HV-2
RA UP
SA
SA DOWN
RA
SA
EXISTING RTU ROOF
CURB TO REMAIN,
RE & RE
1
RA
EXISTING RTU ROOF
CURB
EXISTING RTU ROOF
CURB TO REMAIN,
RE & RE
1
5' MIN. DISTANCE
SA
RA
SA
6' MIN. DISTANCE
HV-1
HV-2
RA UP
SA
SA DOWN
RA
SA
REMOVE EXISTING
ROOF TOP UNIT
EXISTING RTU ROOF CURB TO
REMAIN, PATCH AND REPAIR
ROOF AS NECESSARY TO
HOUSE NEW UNIT, SEE DETAIL
PER MECH.
REMOVE EXISTING
ROOF TOP UNIT
EXISTING RTU ROOF
CURB TO REMAIN,
PATCH AND REPAIR
ROOF AS NECESSARY
TO HOUSE NEW UNIT,
SEE DETAIL PER MECH.
REMOVE POWER WIRING AND RACEWAY FROM EXISTING HV-2 PER ELECTRICAL.
PROVIDE NEW FEEDERS FOR HV-2 PER ELECTRICAL AS APPROVED
REMOVE POWER WIRING AND RACEWAY FROM EXISTING HV-1 PER ELECTRICAL.
PROVIDE NEW FEEDERS FOR HV-1 PER ELECTRICAL AS APPROVED
1
1
HV-1
HV-3
USE OR MODIFY
EXISTING RTU ROOF
CURB TO HOUSE
NEW HV-3
1
REMOVE POWER WIRING AND RACEWAY FROM EXISTING HV-3 PER ELECTRICAL.
PROVIDE NEW FEEDERS FOR HV-3 PER ELECTRICAL AS APPROVED
REMOVE EXISTING
ROOF TOP UNIT
EXISTING RTU ROOF
CURB TO REMAIN,
PATCH AND REPAIR
ROOF AS
NECESSARY TO
HOUSE NEW UNIT,
SEE DETAIL PER
MECH.
1
PROVIDE ROOF CURB ADAPTOR KIT TO UTILIZE EXISTING ROOF CURB.
CONTRACTOR TO SEAL AND WEATHER PROOF AND UNUSED EXISTING
OPENING. REFER TO DETAIL ON MECHANICAL DRAWINGS.
PATCH ROOF ON CURBS C/W FLASHING AND COUNTER FLASHING 12" AND
RE & RE.
REFER TO MECHANICAL AND ELECTRICAL DRAWINGS.
EXISTING RTU ROOF CURB TO REMAIN, PATCH AND REPAIR ROOF
MEMBRANE C/W PLYWOOD, AS NECESSARY TO HOUSE NEW RAISED UNIT.
ROOF CURB TO BE WEATHER RESISTANT AND INSULATED.
1. ACOUSTICAL INSULATIONS REPLACEMENT WITHIN THE EXISTING
ROOF CURBS, REINFORCING THE EXISTING ROOF CURBS.
2. ROOF CURB TO BE RCABC STANDARDS
1
KEYED NOTES:
E F G H J
6
7
8
9
BA
5
6
B13 ELEC.
APPROX. LOCATION OF EXISTINGELEC. ROOM B13 IN BASEMENT
APPROX. LOCATION OF 5" DIA.PIPE PENETRATION FORELECTRICAL CONDUITS, REFERTO DETAIL 3/A107
G H J
3
4
Scale: N.T.S
TYP. GOOSENECK PENETRATION DETAIL
3
TYPICAL ROOF
ASSEMBLY
COUNTER FLASHING
BACK DRAFT DAMPER
SEAL ALL SHEET
METAL AND MAKE
WATER TIGHT WITH
HIGH VELOCITY DUCT
SEALER
1/2"X1/2" BIRDSCREEN
3
0
°
24"
12"
Revision
1 20 Mar 2019 Issued for Review for Tender
2 25 Mar 2019 Issued for Tender
I:\PROJECTS\Year 2019\19028 - New West City - Century House AC system addition-archKJ\DWGS\Phase 6 Bidding\19128-6-A-Century House-AC Sys Add.dwg
220 - 12 Water Street
Vancouver, BC V6B 1A5
604 - 736 - 5581
IREDALE
A R C H I T E C T U R E
Vancouver Victoria
iredale.ca
CENTURY HOUSE
AC SYSTEM ADDITION
620 EIGHTH STREET,
NEW WESTMINSTER, BC
SA BL KBJ
19028
25 MAR 2019 6
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
SCALE:
1
A107
1/4" = 1'-0"
PARTIAL ROOF PLAN - STORAGE/ CEDAR ROOMS
SCALE:
2
A107
1/4" = 1'-0"
PARTIAL ROOF PLAN - LOUNGE AREA
ROOF
PARTIAL PLANS -
STORAGE/ CEDAR ROOMS
AND
LOUNGE AREA
1/4" = 1'-0"
A107
SCALE:
3
A107
1/4" = 1'-0"
PARTIAL ROOF PLAN - PIPE PENETRATION
N
POWER, LOW TENSION AND LIGHT SYMBOL SCHEDULE
DUPLEX G.F.C.I. RECEPTACLE OUTLET 5-20R
PULLBOX
NON FUSABLE DISCONNECT SWITCH
DIRECT HARD WIRE CONNECTION TO DEVICE
ELECTRIC MOTOR
DOUBLE OR THREE PHASE JUNCTION BOX
SINGLE PHASE JUNCTION BOX
DUPLEX RECEPTACLE OUTLET
DRAWING LIST
E-0 - DRAWING LIST, MECH. SCHEDULE AND SINGLE LINEE-1 - PARTIAL POWER PLAN - BASEMENTE-2 - PARTIAL POWER PLAN - LEVEL 1E-2 - PARTIAL POWER PLAN - ROOFE-4 - PANEL SCHEDULESE-5 - ELECTRICAL SPECIFICATION
TOTAL DRAWINGS: 6
BUILDING SITE INFORMATION:
CIVIC ADDRESS:620 EIGHTH STREET, NEW WESTMINSTER, BC
LEGAL DESCRIPTION:PID
DESIGN INTENT:
PROVIDE ELECTRICAL ENGINEERING FOR COMPLIMENTARYPOWER FOR MECHANICAL EQUIPMENT.AS PER MECHANICAL CONSULTANT, INTERLOCK BETWEENNEW MECHANICAL UNITS AND THE EXISTING FIRE ALARMSYSTEM IS NOT REQUIRED.
100A
(80)
200A
(200)
DISHWASHER
42 CCTPNL A
200A-2P
42 CCTPNL B1-42
42 CCTPNL B43-84
30 CCTPNL W
30 CCTPNL X
30 CCTPNL Y
42 CCTPNL Z
400A2P
400A 120/208V 1PHASE 3 WIRE BUSS
100A
(100)
200A
(175)
100A
(100)
XXA
(XX)200A-2P
42 CCTPNL B
400A3P
400A 120/208V 3PHASE 4 WIRE BUSS
200A-2P
42 CCTPNL A
200A-2P
42 CCTPNL C
200A
(150)80A-3P50A-3P
HV-3HV-2 HV-1
35M
MC
-3#
3AW
G+
BO
ND
(C
U)
27M
MC
-3#
4AW
G+
BO
ND
(C
U)
53M
MC
-3#
2/0A
WG
+B
ON
D (
CU
)
M UTILITY C/T'S & METERING
400A2P
120/208V100kW
GENSETA.T.S.
400A3P
M UTILITY C/T'S & METERING
1200A 120/208V 3PHASE 4 WIRE SECONDARY BUS
200A3P
M UTILITY METERING
EXISTING CENTURY HOUSEEXISTING YOUTH CENTRE
TO EXISTING PARK &RECREATIONS BUILDING
TO W/R. BUILDING INSPLASH PARK
200A3P
M UTILITY METERING
200A3P
M UTILITY METERING
200A3P
M UTILITY METERING
EXISTING OUTDOOR UNIT SUBSTATION
EXISTING CENTURY HOUSEELECTRICAL ROOM
EXISTING YOUTH CENTREELECTRICAL ROOM B13
200A-2P
1200A3P
SCALE:
1
E-0
N.T.S.
POWER SINGLE LINE DIAGRAM
ELECTRICAL PANEL BOARD
F FUSIBLE DISCONNECT SWITCH
EXISTING DEVICES SHOWN IN GRAY COLOUR OR EXIST.
NEW DEVICES AND FEEDERS SHOWN IN BLACK COLOUR.
FUSE
DISCONNECT SWITCH
BREAKER
KEY NOTES:
EXISTING DISTRIBUTION PANEL A IN YOUTH CENTRE IS POW-R-LINE -1ABY EATON. CONTACT THE MANUFACTURER FOR LISTED REQUIREDBREAKERS.
PROVIDE HEAVY DUTY FUSED DISCONNECT SWITCH 200A 120/208V 3PHASE 1HD324N BY EATON OR APPROVED EQUAL.
1
1
22
PROJECT NO.
DRAWING TITLE:DATE
CHECKED BYDRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
SEAL:
CONSULTANT:
7268
FEB. 07, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.G.A.G.
DESCRIPTIONDATEREV.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
INFORMATION CONTAINED ON THESE DOCUMENTS IS PART OF ACUMENENGINEERING LTD. INSTRUMENTS OF SERVICE, AND ACUMEN ENGINEERING LTD.
SHALL RETAIN OWNERSHIP THEREOF. SUCH INFORMATION SHALL NOT BE USED FORANY PURPOSE OTHER THAN FOR THE CONSTRUCTION/IMPLEMENTATION OF THE
REFERENCED PROJECT. ANY OTHER USE, REUSE OR MODIFICATION OF THEDOCUMENTS WITHOUT THE ACUMEN ENGINEERING LTD. PRIOR WRITTEN CONSENT
WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO THE CONSULTANT. PAYMENT OF ALL SUMS DUE TO ACUMEN
ENGINEERING LTD. UP TO THE DATE OF THE INTENDED USE OF THIS DRAWING IS ACONDITION PRECEDENT TO THE USE THEREOF.
DRAWING LIST,
MECH.SCHEDULE
AND SINGLE LINE
E-0
2019.02.26 ISSUED FOR COORDINATION1.2019.03.20 ISSUED FOR TENDER2.
GENERAL NOTES FOR DRAWINGS E-0 - E-4 :
1. THE INFORMATION SHOWN ON THE DRAWINGS IS THE RESULT OF INFORMATION OBTAINED FROM AVAILABLE RECORD DRAWINGSAND FIELD SURVEYS. THE CONTRACTOR MUST INCLUDE IN THEIR TENDER FOR THE DISCONNECTION AND REMOVAL OF ALLELECTRICAL DEVICES, FEEDERS AND BRANCH WIRING AND RACEWAYS REQUITED TO FACILITATE THE DEMOLITION WORK ASDESCRIBED ON ALL OF THE DRAWINGS ( ARCHITECTURAL, MECHANICAL, ELECTRICAL, HAZMAT REPORT) WHETHER SHOWN HERE ORNOT. CLAIMS FOR EXTRA COSTS RELATED TO THIS DEMOLITION WORK WILL NOT BE ACCEPTED. ALL REMOVED EQUIPMENT NOTREQUESTED BY THE OWNER SHALL BE DISPOSED OF BY THE CONTRACTOR.
2.UNLESS REQUIRED TO BE REMOVED BY THE DEMOLITION WORK, ALL EXISTING DEVICES SHOWN ARE TO BE RETAINED ANDPROTECTED FROM DAMAGE.
3.CONTRACTOR IS TO CONFIRM ALL EXISTING CIRCUITS AND RECORD ASSOCIATED PANELS ON THE RECORD DRAWINGS IN RED INK.
4. CIRCUIT NUMBERS ARE SHOWN TO INDICATE THE INTENT OF THE POWER CONNECTION. ACTUAL NUMBERS MAY CHANGE DUE TOSITE CONDITION.
5. COORDINATE LOCATION OF ALL POWER OUTLET INSTALLATION WITH THE OWNER PRIOR ROUGH-IN.
6. CONFIRM ROUTING OF ALL SURFACE RACEWAYS, FEEDERS, AND CONDUITS WITH THE OWNER'S REPRESENTATIVE BEFOREINSTALLATION. OBTAIN APPROVAL IN WRITING.
7. CONTRACTOR TO ALLOW IN TENDER BID FOR AFTER HOURS AND WEEKEND WORK IN OPERATIONAL BUILDING AREAS. SCHEDULEWORKS WITH THE OWNER IN ADVANCE TO MINIMIZE DISRUPTION.
8. POWER WIRING IN RACEWAY FROM PANEL A (CENTURY HOUSE) TO CU-4 AND CU-5 IS BY TECK CABLE IN BULKHEADS FOLLOW TONEW MECHANICAL PIPES IN THIS PROJECT.
9. POWER WIRING FROM PANEL A (CENTURY HOUSE) TO INDOOR UNITS AC-6 - AC-11 IS BY TECK CABLE IN ENCLOSED BULKHEADSAND SURFACE MOUNT WIREMOLD 500/700 SERIES OR EQUAL WITH WIRING ON WALL/CEILING SURFACE TO 15A-2P SURFACE MOUNTDISCONNECT SWITCH IN WIREMOLD BACK BOX WITH COVER PLATE.
10. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION RELATED TO DIV.26 SCOPE OF WORK AND WIRING ROUTES.
11. REFER TO PANEL SCHEDULE ON DRAWING E-4 FOR NEW BREAKER SIZE AND LOCATION.
12. PROVIDE UPDATED TYPEWRITTEN PANEL DIRECTORIES WITH BREAKER SIZE, POLES AND ROOM DESIGNATION IN ALL PANEL AS PERDRAWING E-4.
13. INSOLATED GREEN BONDING WIRE SHALL BE INSTALLED IN ALL EMT AND WIREMOLD RACEWAYS.
DCBA E F G H J K L
1
2
3
4
5
6
7
8
9
10
11
12
CU-4A-6,8
AC-11A-9,11
AC-10A-9,11
AC-9A-9,11
CU-5A-10,12
AC-8A-9,11
AC-7A-9,11
AC-6A-9,11
SCALE:
1
E-1
1'-0" = 3/32"
PARTIAL POWER PLAN - BASEMENT
EXIST.PNL 'A'CENTURYHOUSE
EXIST.PNL 'X'
NEW 200A-3PDISCONNECTSWITCH WITH150A FUSESFOR HV-1
EXIST. FIREALARM PANELYOUTH CENTRE
J
4
3
SCALE:
2
E-1
1'-0" = 1/2"
YOUTH CENTRE ELEC. ROOM LAYOUT
EXIST. 400A120/208V 3PHGUTTER BELOW.
EXIST.PNL 'B'YOUTHCENTRE
EXIST.PNL 'C'YOUTHCENTRE
EXIST.PNL 'A'YOUTHCENTRE
EXIST. ACCESSCONTROL PANELYOUTH CENTRE
2
E-1
APPROX. CONDUITROUTES TO ROOF.
RELOCATE EXIST. BIX BLOCK, RECEPTACLES, EXTEND EMTCONDUIT AND WIRING FOR SECURITY AND COMM. EQUIPMENTCLOSE TO F.A. PANEL. PROVIDE ADDITIONAL BIX BRACKETS ASREQUIRED.
PROJECT NO.
DRAWING TITLE:DATE
CHECKED BYDRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
SEAL:
CONSULTANT:
7268
FEB. 07, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.G.A.G.
DESCRIPTIONDATEREV.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
INFORMATION CONTAINED ON THESE DOCUMENTS IS PART OF ACUMENENGINEERING LTD. INSTRUMENTS OF SERVICE, AND ACUMEN ENGINEERING LTD.
SHALL RETAIN OWNERSHIP THEREOF. SUCH INFORMATION SHALL NOT BE USED FORANY PURPOSE OTHER THAN FOR THE CONSTRUCTION/IMPLEMENTATION OF THE
REFERENCED PROJECT. ANY OTHER USE, REUSE OR MODIFICATION OF THEDOCUMENTS WITHOUT THE ACUMEN ENGINEERING LTD. PRIOR WRITTEN CONSENT
WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO THE CONSULTANT. PAYMENT OF ALL SUMS DUE TO ACUMEN
ENGINEERING LTD. UP TO THE DATE OF THE INTENDED USE OF THIS DRAWING IS ACONDITION PRECEDENT TO THE USE THEREOF.
PARTIAL POWER PLAN
BASEMENT
E-1
2019.02.26 ISSUED FOR COORDINATION1.2019.03.20 ISSUED FOR TENDER2.
DCBA E F G H J K L
1
2
3
4
5
6
7
8
9
10
11
12
CU-3Z-40,42
AC-5(CU-3)
FF-1B-56,58
EXEF-1B-60
T R
CU-1W-28,30
AC-4(CU-1)
CU-2B-82,84
AC-1(CU-2)
AC-2(CU-2)
AC-3(CU-2)
HRV-1(A) HRV-1(B)
HRV-2(A)
HRV-2(B)
HRV-3(A) HRV-3(B)
B13 ELEC.IN BSMT.
SCALE:
1
E-2
1'-0" = 3/32"
PARTIAL POWER PLAN - LEVEL 1
EXIST.PNL 'Z'
APPROX. LOCATION OFEXISTING ELEC. ROOMB13 IN BASEMENT
2
J
J
J
3
3
3
B-80 B-80
B-80
B-80
KEY NOTES:
REMOVE EXISTING ENTRANCE FORCE FLOW HEATER AND ASSOCIATED WIRING TO THE SOURCE(PANEL B). PROVIDE SURFACE MOUNT RACEWAY WIREMOLD 500/700 SERIES OR APPROVED EQUALWITH WIRING TO NEW LOCATION OF FF-1 ABOVE THE ENTRANCE. ALLOW FOR ALL REQUIREDPARTS TO INSTALL COMPLETE WIREMOLD 500/700 SERIES RACEWAY ON WALL/CEILING .
RELOCATE DOWN EXISTING EXIT SIGN FROM THE CEILING ABOVE THE ENTRANCE TO PANELBETWEEN THE CEILING AND THE ENTRANCE DOOR. EXTEND SURFACE MOUNT RACEWAYWIREMOLD 500/700 SERIES OR APPROVED EQUAL WITH WIRING TO NEW LOCATION OF EXIT SIGN.EXIT SIGN SHALL BE VISIBLE AFTER INSTALLATION OF NEW FORCE FLOW HEATER.
PROVIDE SURFACE MOUNT RACEWAY WIREMOLD 500/700 SERIES OR APPROVED EQUAL WITHWIRING FOR SMART COMFORT CONTROLLER POWER SUPPLY 120V/12V C/W DOUBLE GANGE BACKBOX AND BLANK COVER PLATE FOR THE POWER SUPPLY. PROVIDE WIREMOLD RACEWAY FOR LVWIRING BETWEEN POWER SYPPLY AND HRV UNITS. LV WIRING IS BY DIV.25. COORDINATEADDITIONAL REQUIREMENTS AND EXACT MOUNT LOCATION WITH THE OWNER AND MECHANICALCONSULTANT/CONTRACTOR BEFORE TO ROUGH-IN.HRV-1(A) - HRV-3(B) PROVIDED BY DIV.25 AND SHOWN FOR REFERENCE ONLY.
FEEDERS FOR CU-1, CU-2, CU-3 TO BE SURFACE MOUNTED WIREMOLD 500/700 SERIES ORAPPROVED EQUAL WITH TRANSITION BY TECK CABLE TO OUTSIDE UNIT. TECK CABLE IN ENCLOSEDBULKHEADS AND IN ATTIC SPACE.
DISCONNECT EXIST. POWER OUTLET FOR AC UNIT AND MAKE SAFE WIRING. TRACE EXISTINGCIRCUIT TO THE SOURCE (DIST. PANEL) AND UPDATE TYPEWRITTEN DIRECTORY AND RECORDCIRCUIT NUMBER ON AS-BUILT DRAWINGS ACCORDINGLY.
1
2
EXIST. PNL 'B'(DOUBLE TUB)
EXIST.PNL 'W'
EXIST.PNL 'W'
3
4
4
4
4
EXIST. ELEC. RM. INCENTURY HOUSE
1
APPROX. ROUTE FORSURFACE MOUNTEDRACEWAYS BELOWSKYLIGHT.
5
5
5
PROJECT NO.
DRAWING TITLE:DATE
CHECKED BYDRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
SEAL:
CONSULTANT:
7268
FEB. 07, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.G.A.G.
DESCRIPTIONDATEREV.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
INFORMATION CONTAINED ON THESE DOCUMENTS IS PART OF ACUMENENGINEERING LTD. INSTRUMENTS OF SERVICE, AND ACUMEN ENGINEERING LTD.
SHALL RETAIN OWNERSHIP THEREOF. SUCH INFORMATION SHALL NOT BE USED FORANY PURPOSE OTHER THAN FOR THE CONSTRUCTION/IMPLEMENTATION OF THE
REFERENCED PROJECT. ANY OTHER USE, REUSE OR MODIFICATION OF THEDOCUMENTS WITHOUT THE ACUMEN ENGINEERING LTD. PRIOR WRITTEN CONSENT
WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO THE CONSULTANT. PAYMENT OF ALL SUMS DUE TO ACUMEN
ENGINEERING LTD. UP TO THE DATE OF THE INTENDED USE OF THIS DRAWING IS ACONDITION PRECEDENT TO THE USE THEREOF.
PARTIAL POWER PLAN
LEVEL 1
E-2
2019.02.26 ISSUED FOR COORDINATION1.2019.03.20 ISSUED FOR TENDER2.
KEY NOTES:
REMOVE POWER WIRING AND RACEWAY FROM EXISTING HV-1, HV-2, ANDHV-3 TO THE SOURCE (DISTRIBUTION PANELS). CONTRACTOR IS TOIDENTIFY THE POWER SOURCE FOR HV-3 AND REPORT FINDINGS TOCONSULTANT.
PROVIDE NEW FEEDERS FOR HV-1, HV-2, AND HV-3 C/W ROOF CONDUITSUPPORT BLOCKS (DURA-BLOK ROOF SUPPORT BY EATON OR APPROVEDEQUAL) AS REQUIRED.
PROVIDE HVAC MAINTENANCE DUPLEX GFCI RECEPTACLES AT +750 MMAFTER FINISHED ROOF WITH WEATHER PROOF COVER AS PER CEC 26-702.
1
DCBA E F G H J K L
1
2
3
4
5
6
7
8
9
10
11
12
HV-3A-21,23,25YOUTHCENTRE
HV-1REFERTO SLD.
HV-2A-27,29,31YOUTHCENTRE
B13 ELEC.
EXISTINGCU UNITYOUTHCENTRE
SCALE:
1
E-3
1'-0" = 3/32"
PARTIAL POWER PLAN - ROOF
APPROX. LOCATION OFEXISTING ELEC. ROOMB13 IN BASEMENT
SUGGESTED FEEDER ROUTES ONROOF FOR HV-1, HV-2, HV-3.HEAVY GALVANIZED EMT CONDUITSYSTEM WITH RAIN-TIGHTCONNECTORS, COUPLINGS ANDWEATHER PROOF PULL BOXES.QUANTITY AS REQUIRED. ALLOWFOR ELEVATIONS CHANGES ANDADDITIONAL ELECTRICALEQUIPMENT SUCH AS SUPPORTBLOCKS ON ROOF, ETC. TO FORMCOMPLETE ELECTRICAL RACEWAYSYSTEM.
+750MM AFR5-20R A-39YOUTHCENTRE
WP
+750MM AFR5-20R A-37YOUTHCENTRE
WP
2
2
2
1
1
1
3
3
3
PROJECT NO.
DRAWING TITLE:DATE
CHECKED BYDRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
SEAL:
CONSULTANT:
7268
FEB. 07, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.G.A.G.
DESCRIPTIONDATEREV.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
INFORMATION CONTAINED ON THESE DOCUMENTS IS PART OF ACUMENENGINEERING LTD. INSTRUMENTS OF SERVICE, AND ACUMEN ENGINEERING LTD.
SHALL RETAIN OWNERSHIP THEREOF. SUCH INFORMATION SHALL NOT BE USED FORANY PURPOSE OTHER THAN FOR THE CONSTRUCTION/IMPLEMENTATION OF THE
REFERENCED PROJECT. ANY OTHER USE, REUSE OR MODIFICATION OF THEDOCUMENTS WITHOUT THE ACUMEN ENGINEERING LTD. PRIOR WRITTEN CONSENT
WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO THE CONSULTANT. PAYMENT OF ALL SUMS DUE TO ACUMEN
ENGINEERING LTD. UP TO THE DATE OF THE INTENDED USE OF THIS DRAWING IS ACONDITION PRECEDENT TO THE USE THEREOF.
PARTIAL POWER PLAN
ROOF
E-3
2019.02.26 ISSUED FOR COORDINATION1.2019.03.20 ISSUED FOR TENDER2.
PROJECT NO.
DRAWING TITLE:DATE
CHECKED BYDRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
SEAL:
CONSULTANT:
7268
FEB. 07, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.G.A.G.
DESCRIPTIONDATEREV.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
INFORMATION CONTAINED ON THESE DOCUMENTS IS PART OF ACUMENENGINEERING LTD. INSTRUMENTS OF SERVICE, AND ACUMEN ENGINEERING LTD.
SHALL RETAIN OWNERSHIP THEREOF. SUCH INFORMATION SHALL NOT BE USED FORANY PURPOSE OTHER THAN FOR THE CONSTRUCTION/IMPLEMENTATION OF THE
REFERENCED PROJECT. ANY OTHER USE, REUSE OR MODIFICATION OF THEDOCUMENTS WITHOUT THE ACUMEN ENGINEERING LTD. PRIOR WRITTEN CONSENT
WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO THE CONSULTANT. PAYMENT OF ALL SUMS DUE TO ACUMEN
ENGINEERING LTD. UP TO THE DATE OF THE INTENDED USE OF THIS DRAWING IS ACONDITION PRECEDENT TO THE USE THEREOF.
SCHEDULES
E-4
2019.02.26 ISSUED FOR COORDINATION1.2019.03.20 ISSUED FOR TENDER2.
1.0 GENERAL PROVISIONS
1.01 THE GENERAL CONDITIONS OF THE CONTRACT SHALL FORM ANINTEGRAL PART OF THE SPECIFICATION.
1.02 PROVIDE ALL LABOUR AND MATERIALS NECESSARY FOR ACOMPLETE AND OPERATING SYSTEM AS INDICATED ON THEDRAWINGS AND/OR SPECIFIED HEREIN. ANY WORK ANDMATERIAL, EVEN IF NOT SHOWN OR SPECIFIED THAT ISOBVIOUSLY NECESSARY OR REASONABLY IMPLIED TO COMPLETETHE WORK TO BE PROVIDED AS IF IT WAS BOTH SHOWN ANDSPECIFIED.
1.03 ALL ELECTRICAL WORK AND MATERIAL SHALL CONFORM WITHTHE CURRENT RELEVANT AND/OR APPLICABLE BUILDING CODE,ELECTRICAL SAFETY ACT OF THE JURISDICTION, CURRENTPURSUANT REGULATION (ELECTRICAL CODE REGULATION,ELECTRICAL SAFETY BULLETINS, ETC) AND TO THE SATISFACTIONOF THE AUTHORITY HAVING JURISDICTION AND THE DESIGNPROFESSIONAL. FOR THE PURPOSE OF THIS SPECIFICATIONINTERPRETATION OF THE WORD "CODE" SHALL MEAN ALL CODES,REGULATIONS AND REQUIREMENTS AS STATED ABOVE.
1.04 VISIT THE SITE AND ASCERTAIN CONDITIONS AFFECTING THEWORK BEFORE SUBMITTING A TENDER QUOTE.
1.05 APPLY FOR ALL PERMITS, SERVICES, FEES AND INSPECTIONS ANDPAY FOR ALL FEES TO THE AUTHORITIES HAVING JURISDICTION.INCLUDE ALL COST IN TENDER QUOTE.
1.06 OBTAIN APPROVALS FROM THE ELECTRICAL INSPECTIONAUTHORITY AND NOTIFY THE ENGINEER OF ANY CHANGESREQUESTED BY THE INSPECTION AUTHORITY.
1.07 WHERE DOUBT EXISTS AS TO THE MEANING OF THE DRAWINGSOR SPECIFICATIONS, OBTAIN CLARIFICATION PRIOR TO TENDER.
1.08 SHOP DRAWINGS FOR ELECTRICAL EQUIPMENT/ MATERIALSSHALL BE SIGNED, DATED, STAMPED BY BOTH GC/EC ANDSUBMITTED FOR REVIEW BY ENGINEER BEFORE MANUFACTURINGAND INSTALLATION CAN PROCEED.
1.09 INCLUDE ALL FEDERAL, PROVINCIAL AND MUNICIPAL TAXES FORTHE WORK IN THE TENDER PRICE.
1.10 ALL MATERIALS USED SHALL BE NEW, OF THE TYPE SPECIFIED,AND APPROVED BY CERTIFICATION AGENCY RECOGNIZED BYAUTHORITY BARING JURISDICTION, AND FREE FROM DEFECTS.
1.11 ALL ELECTRICAL EQUIPMENT INSTALLED OR CONNECTED SHALLBE IDENTIFIED BY MEANS OF BLACK LAMICOID LABELS c/wMINIMUM 3/8" WHITE LETTERING.
1.12 CLEAN ALL EQUIPMENT DURING CONSTRUCTION AND AGAIN ONCOMPLETION OF THE CONTRACT.
1.13 REMOVE ALL SURPLUS MATERIALS, CUTTINGS, PACKAGING ANDDEBRIS FROM THE SITE DURING THE PROGRESS AND AT FINALCOMPLETION OF THE WORK.
1.14 THE OWNER RESERVES THE RIGHTS OF TRIAL OR TEMPORARYUSAGE PRIOR TO ACCEPTING THE INSTALLATION.
1.15 EXECUTE ALL WORK IN A WORKMANLIKE MANNER, TO PRESENT ANEAT MECHANICAL APPEARANCE.
1.16 COORDINATE WITH ALL TRADES AND ARRANGE EQUIPMENT INPROPER RELATION WITH OTHER APPARATUS, DUCTS, PIPES, ETC.AND WITH BUILDING CONSTRUCTION AND ARCHITECTURALFINISHES.
1.17 ALL RECEPTACLE COVER PLATES, SWITCH COVER AND EXHAUSTFAN SWITCH COVERS TO BE c/w DYMOTAPE LABELS INDICATINGPANEL NAME AND CIRCUIT NUMBERS (EXCEPT FOR RESIDENTIALDWELLING UNITS ONLY).
1.18 BUILDING ENVELOPE PENETRATION OF ANY ELECTRICALCOMPONENT (i.e. CONDUIT, BOXES, CABLES, ETC.) SHALL BEEXECUTED SO INTEGRITY OF ASSEMBLY IS NOT COMPROMISED.PROVIDE FOR ADEQUATE SEALING, COVERS, GASKETS, CAPS,ETC. COORDINATE WORK AND REQUIREMENTS WITH ALL OTHERRELEVANT CONTRACTORS, ARCHITECT, ENVELOPE CONSULTANTAND OTHER RELEVANT CONSULTANTS AND CONTRACTORS.
1.20 LIABILITY AND EXCLUSIONS
.1 ACUMEN ENGINEERING LTD. DRAWINGS, SPECIFICATIONS ANDOTHER DOCUMENTS PERTAIN TO ELECTRICAL SCOPE OFWORK ONLY.
.2 TASKS WHICH ARE NOT PART OF ELECTRICAL SCOPE OF WORKEVEN IF MENTIONED IN THESE DOCUMENTS ARE INDICATEDONLY FOR REFERENCE AND COORDINATION PURPOSES ONLY.
.3 WORK PERFORMED BY CONTRACTOR NOT SPECIFICALLYIDENTIFIED AS PART OF THE SCOPE OF WORK SHALL BEPERFORMED WITH A CLEAR UNDERSTANDING THAT ACUMENENGINEERING LTD., AND ANY AGENTS OR EMPLOYEES OFACUMEN ENGINEERING LTD. ARE NOT IN ANY WAY LIABLE NORRESPONSIBLE FOR THIS WORK.
.4 GENERALLY THE SCOPE OF WORK IS LIMITED TO DIV. 26 OFNATIONAL MASTER SPECIFICATION.
.5 SPECIFICALLY, ACUMEN ENGINEERING LTD. DOES NOTPROVIDE ANY ENGINEERING/CONSULTING SERVICES RELATEDTO BUILDING ENVELOPE, WATERPROOFING AND ANY OTHERNON-ELECTRICAL COMPONENTS. THIS APPLIES TO BUT IS NOTLIMITED TO ALL AND ANY ELECTRICAL PENETRATIONS ANDINSTALLATIONS THROUGHOUT OR WITHIN BUILDINGENVELOPE.
2.0 CONDUIT, WIRE AND CONNECTIONS
2.01 DRAWINGS ARE SCHEMATIC ONLY. CONDUIT RUNS SHOWNINDICATE POINTS TO BE JOINED. REFER TO MECHANICALDRAWINGS FOR ADDITIONAL INFORMATION ABOUT POWERWIRING IN ENCLOSED BULKHEADS. RUNS MAY BE ALTERED BYTHE CONTRACTOR TO SUIT ACTUAL FIELD CONDITIONS AND WITHAPPTOVAL BY THE OWNER'S REPRESENTATIVE. ELECTRICALDRAWINGS ONLY GIVE INDICATION OF FEATURES OF OTHERTRADES. ARCHITECTURAL, STRUCTURAL AND MECHANICALDRAWINGS GOVERN WHERE THESE ARE INVOLVED.
2.02 WIRING DEVICES IN FINISHED AREAS SHALL BE SURFACEMOUNTED WIREMOLD 500/700 SERIES AND FOR ALL UNFINISHEDAREAS (CRAWL SPACE) MAY BE SURFACE MOUNTED IN CONDUITS.
2.03 A WARNING SIGN SHALL BE PLACED NEAR ALL MOTORS WITH THEFOLLOWING WORDING: "DO NOT SERVICE UNTIL DISCONNECTSARE LOCKED OFF".
2.04 FINAL CONNECTIONS TO MOTORS SHALL BE WITH MIN. 18" LONGFLEX CONDUIT, PROVIDE DISCONNECTS AS PER CODEREQUIREMENTS.
2.05 UNLESS OTHERWISE NOTED, USE MINIMUM #12 RW90 GREENBOND WIRE IN ALL WIREMOLD RACEWAYS. INCREASE WIREGAUGE ACCORDING TO LOAD AND DISTANCE.
2.06 TEST SYSTEM AND RECORD SAME FOR THE ENGINEER'S
APPROVAL:.1 VOLTAGE DROP.2 PHASE BALANCE.3 INSULATION RESISTANCE.4 GROUND RESISTANCE
2.07 ALL WIRE AND CABLE SHALL BE COPPER, 98% CONDUCTIVITY,COLOUR CODED, NEW AND MARKED AS PER CODEREQUIREMENTS AND INSTALLED IN RACEWAYS. WIRES SHALL BERATED MIN. 600V TYPE TWH OR R90X-LINK. RW90 SHALL BE USEDFOR UNDERGROUND RACEWAY INSTALLATIONS.
2.08 ALL WIRING SHALL BE SIZED AS PER CODE MINIMUM ALLOWABLEWIRE SIZE IS #12 AWG. USE MINIMUM #14 GTF FOR LIGHT FIXTURECONNECTIONS. CONDUCTORS #8 AND LARGER TO BE STRANDED.ALL WIRES INSTALLED IN CONDUIT SHALL BE PULLED IN AT THESAME TIME. ONLY APPROVED PULLING LUBRICANT SHALL BEUSED. COLOUR CODE CONDUCTORS WITH DIFFERENT COLOURSFOR EACH PHASE, NEUTRAL, GROUND AND BOND WIRES ASREQUIRED BY CODE.
2.09 MAXIMUM VOLTAGE DROP SHALL BE AS PER CODEREQUIREMENTS.
2.10 ALL CONDUITS, CABLES AND WIRES, ETC., TO BE RATED FT4 ANDFT6 FOR PLENUM AND AS REQUIRED BY THE CODE.
2.11 ALL WIRE CONNECTIONS TO BE SECURELY FASTENED BY MEANSOF APPROVED CONNECTORS.
2.12 ALL NON-CURRENT CARRYING METAL PARTS SHALL BEGROUNDED AND/OR BONDED IN ACCORDANCE WITH THE CODE.
2.13 THE BUILDING STRUCTURAL STEEL SHALL BE BONDED TO THEGROUND SYSTEM.
2.14 OPENINGS IN ALL ELECTRICAL METAL BOXES SHALL BE PUNCHEDOR CUT. BURNING OF HOLES IS NOT PERMITTED.
2.15 INSTALL ALL CONDUITS, ETC. TO ACCOUNT FOR EXPANSION ANDINSTALL APPROVED EXPANSION JOINTS WHERE REQUIRED.
2.16 RACEWAYS SHALL BE RIGID METAL CONDUITS, EMT OR FLEXIBLECONDUIT AS SHOWN ON THE DRAWINGS, ALL CONDUIT INSTALLEDIN CONCRETE FLOOR SHALL BE RIGID P.V.C. OR RIGIDGALVANIZED STEEL CONDUIT c/w BOND CONDUCTOR.
2.17 EMT COUPLINGS AND CONNECTORS TO BE T & B STEEL, TAPE ALLJOINTS FOR ALL IN-SLAB INSTALLATIONS. STEEL SHALL BE USEDABOVE GRADE.
2.18 USE OF RUNNING THREADS IS NOT PERMITTED.
2.19 ALL CONDUITS MUST BE SECURELY FASTENED WITH APPROVEDCLIPS AND SCREWS IN PARTITIONS AND CADDY CLIPS IN CEILING.NAILS ARE NOT ACCEPTED.
2.20 SEE ARCHITECTURAL DRAWINGS. EXPOSED EMT CONDUITS SHALLRUN PARALLEL TO BUILDING LINES AND BE PAINTED OUT TOMATCH WALL FINISH. WHERE CONDUITS ARE RUN EXPOSED ONEXISTING SURFACES PAINT TO MATCH WALL FINISH.
2.21 PROVIDE OUTLET BOXES FOR CONNECTING TO DEVICES ANDEQUIPMENT AS REQUIRED OR AS INDICATED ON DRAWINGS.LOCATIONS OF OUTLETS MAY BE CHANGED UP TO 15'-0" WITHOUTEXTRA CHARGE PROVIDED THAT INSTRUCTIONS FOR CHANGEARE ISSUED BEFORE INSTALLATION OF THE OUTLET.
2.22 ALL CONDUIT, CONDUCTORS, WIRES, ETC. TO BE LABELED ININDELIBLE INK AT PANEL AND JUNCTION BOXES INDICATINGDEVICE FED, PANEL NAME AND CIRCUIT NUMBER
2.23 PRIOR TO INSTALLATION OF ANY CONDUIT IN CONCRETE SLABS,CONTRACTOR SHALL COORDINATE LAYOUT AND REQUIREMENTSWITH STRUCTURAL ENGINEER.
2.24 ALL EMPTY CONDUITS SHALL BE C/W APPROVED FORAPPLICATION PULL STRINGS.
3.0 DISTRIBUTION EQUIPMENT
3.01 LIGHTING AND POWER PANELS TO BE CIRCUIT BREAKER TYPEAND AS SHOWN ON DRAWINGS: PANELS TO BE OF DEAD FRONTTYPE, CODE GAUGE STEEL ENCLOSURE. FINISHED FACTORYPAINT ASA GRAY 61 ENAMEL. FIT WITH PLASTIC COVERED TYPEDDIRECTORY IN FRAME ON INSIDE OF DOOR COVER. DIRECTORY TOINDICATE CIRCUITS SERVED AS PER FINAL WIRING CONNECTIONS.PANELS TO BE WITH BOLT-ON BREAKERS, MULTI-POLE BREAKERSTO HAVE COMMON TRIP (NO TIE HANDLE WILL BE ACCEPTED).
3.02 PROVIDE LOCK ON DEVICES ON BREAKERS FOR THE FOLLOWINGSYSTEMS..1 FIRE ALARM SYSTEM.2 INTRUSION ALARM SYSTEM.3 EXIT LIGHTS.4 NIGHT LIGHTS
3.03 MAIN DISTRIBUTION CENTRES SHALL BE AS DETAILED ON THEDRAWINGS.
3.04 ALL ELEMENTS OF ELECTRIC POWER DISTRIBUTION SYSTEMSHALL BE RATED FOR PROPER VOLTAGE AND AVAILABLE FAULTLEVELS. OVER CURRENT PROTECTION DEVICES SHALL BEAPPROVED AND MARKED AS BREAKERS OR BREAKER/FUSESCOMBINATION IN SERIES. SHOP DRAWINGS SHALL CLEARLYIDENTIFY THE COMPLIANCE WITH THIS REQUIREMENT.
3.05 PROVIDE DRIP SHIELDS TO ADEQUATELY DEFLECT WATER FROMALL ELECTRICAL EQUIPMENT.
3.06 DISCONNECT SWITCHES SHALL BE SWITCHMATIC HEAVY-DUTYENCLOSED SAFETY SWITCHES OR EQUAL. DISCONNECTSWITCHES SHALL HAVE THE OPERATING HANDLE INTERLOCKEDWITH THE SWITCH COVER, STEEL REINFORCED FUSE CLIPS, AQUICK-MAKE, QUICK-BREAK MECHANISM AND SHALL BEHORSEPOWER RATED FOR 100% LOADING.
3.07 LABEL METER CENTER FUSIBLE DISCONNECTS AND INDICATE THEMAXIMUM PERMISSIBLE RATING OF THE FUSE IN EACHRESPECTIVE DISCONNECT.
3.08 ENSURE THAT THE SERVICE EQUIPMENT BEARS EVIDENCE OF"SUITABLE FOR SERVICE ENTRANCE".
3.09 CONTRACTOR TO PROVIDE SHOCK/FLASH PROTECTION MARKINGON ALL ELECTRICAL EQUIPMENT AS PER C.E.C. RULE 2-306.
6.0 FIRE STOPPING OF SERVICE PENETRATION AND FIRERESISTANT ASSEMBLIES
6.01 ALL ELECTRICAL WIRES, CABLES, NONCOMBUSTIBLE RACEWAYS,OUTLET BOXES AND OTHER SIMILAR SERVICES THAT PENETRATEFIRE WALL, FIRE SEPARATION OR ASSEMBLY REQUIRED TO HAVEA FIRE RESISTANCE RATING OR FIRE SEPARATION, SHALL BESEALED BY FIRE STOP SYSTEM WHICH HAS AN "F" AND/OR "FT"RATING NOT LESS THAN REQUIRED FIRE PROTECTION RATING OFFIRE SEPARATION.
6.02 "F" AND "FT" RATINGS SHALL BE DETERMINED BY FIRE TESTMETHOD CAN4-S115-M "STANDARD METHOD OF FIRE TESTS OF
FIRE STOP SYSTEMS". SEE CURRENT BUILDING CODE, FIRESTOPPING OF SERVICE PENETRATIONS.
6.03 CONTRACTOR SHALL ONLY USE LISTED MATERIALS ANDMETHODS AS LISTED AND INDICATED IN "ULC LIST OF EQUIPMENTAND MATERIALS VOLUME 2, BUILDING CONSTRUCTION" (NO.40U18 FIRE SEPARATION).
6.04 SERVICE PENETRATION AND FIRE STOPPING OF SERVICEPENETRATION IN FIRE SEPARATION AND FIRE RATED ASSEMBLIESSHALL COMPLY WITH THE CURRENT BUILDING CODE.
6.05 PROVIDE FOR FIRE STOPS IN CONCEALED SPACES AS REQUIREDBY THE CURRENT BUILDING CODE.
6.06 ALL FIRE RESISTANCE RATED ASSEMBLIES (i.e. WALLS CEILINGS,ETC.) WHICH CONTAIN PANEL BOARDS, BACK BOXES, ETC. SHALLBE c/w FIRE RATED BACKING TO MAINTAIN THE INTEGRITY OF THEFIRE RESISTANCE.
6.07.1 CONTRACTOR SHALL EMPLOY QUALIFIED FIRESTOP
PROFESSIONAL ENGINEER TO PROVIDE THE DESIGN OF ANDREVIEWS FOR FIRESTOP INSTALLATIONS.
.2 CONTRACTOR SHALL PROVIDE FIRESTOP PROFESSIONALENGINEER LETTERS; ASSURANCE OF PROFESSIONAL DESIGNAND COMMITMENT OF FIELD REVIEW (SCHEDULE B-1),SUMMARY OF DESIGN AND FIELD REVIEW REQUIREMENTS(SCHEDULE B-2), AT THE INSTALL STAGE OF THECONSTRUCTION.
.3 BEFORE SUBSTANTIAL PERFORMANCE CAN BE GRANTEDCONTRACTOR SHALL PROVIDE FIRESTOP PROFESSIONALENGINEER LETTER OF ASSURANCE OF PROFESSIONAL FIELDREVIEW AND COMPLIANCE (SCHEDULE C-B).
.4 ALL COSTS RELATED TO THE ABOVE REQUIREMENTS SHALL BEINCLUDED IN THE CONTRACTOR BASE BID.
7.0 EMERGENCY LIGHTING
7.01 ALL EXIT SIGN LIGHTS MUST BE CONNECTED TO BOTH NORMALPOWER SOURCE AND APPROVED EMERGENCY POWER SOURCE.
8.0 FINAL ACCEPTANCE
8.01 SUBMIT TO THE ENGINEER UPON COMPLETION OF THECONTRACT, TWO MARKED UP SETS OF RECORD DRAWINGS ANDTHREE SETS OF MAINTENANCE MANUALS FOR SERVICE,DISTRIBUTION, PANELS, LIGHT FIXTURES, LAMPS, EXITS,EMERGENCY UNITS, EMERGENCY HEADS, AND FIRE ALARMEQUIPMENT.
8.02 DELIVER TO THE ENGINEER CERTIFICATE OF APPROVAL AND FINALINSPECTION FROM AUTHORITIES HAVING JURISDICTION PRIOR TOFINAL OCCUPANCY. THESE MUST BE PROVIDED THREE WORKINGDAYS BEFORE ENGINEERS FINAL OCCUPANCY REVIEW.
8.03 SUBMIT TO THE ENGINEER A COPY OF CERTIFICATE VERIFYINGTHAT EMERGENCY LIGHTING SYSTEM HAS BEEN TESTED UNDERFULL LOAD AS PER CODE REQUIREMENTS.
8.04 AFTER WORK IS COMPLETED, FURNISH TO OWNER A WRITTENGUARANTEE THAT FOR TWO YEARS FROM DATE OF ACCEPTANCE,ANY DEFECTS IN MATERIALS OR WORKMANSHIP WILL BECORRECTED AT NO COST TO THE OWNER. SUBMIT COPY OFGUARANTEE TO ENGINEER.
8.05 SUBMIT COPIES OF FIRE ALARM VERIFICATION AND TESTINGREPORT TO THE ENGINEER PRIOR TO FINAL ACCEPTANCE. THESEMUST BE PROVIDED THREE WORKING DAYS BEFORE ENGINEERSFINAL OCCUPANCY REVIEW.
11.0 SEISMIC RESTRAINTS
11.01
.1 PROVIDE ALL MATERIALS AND LABOUR NECESSARY TO SUPPLY ANDINSTALL SEISMIC RESTRAINTS FOR ALL ELECTRICAL EQUIPMENT,LIGHT FIXTURES, BATTERY PACKS, CONDUITS, RACEWAYS, BUSDUCTS, ETC. TO CONFORM WITH BUILDING CODE AND ALL OTHERAPPLICABLE REGULATIONS.
.2 CONTRACTOR SHALL RETAIN AND PAY FOR SEISMIC ENGINEER TODESIGN AND INSPECT THE SEISMIC RESTRAINTS OF THEELECTRICAL SYSTEM COMPONENTS COVERED UNDER DIVISION 26FOR THIS CONTRACT.
.3 THE SEISMIC ENGINEER RETAINED BY CONTRACTOR SHALLPROVIDE FOR THE FOLLOWING:
- SIGNED AND SEALED LETTERS OF ASSURANCE OFPROFESSIONAL DESIGN AND COMMITMENT FOR FIELD REVIEWAND SUMMARY OF DESIGN AND FIELD REVIEW AS REQUIRED BYTHE BRITISH COLUMBIA BUILDING CODE (SCHEDULE B1 AND B2,POINT 6.5).
- CERTIFIED DETAILED DRAWINGS OF SEISMIC RESTRAINT.
- DETAILED SPECIFICATION FOR SEISMIC RESTRAINTS.
- WRITTEN REPORTS OF SITE REVIEWS.
- SIGNED AND SEALED LETTER OF ASSURANCE OFPROFESSIONAL FIELD REVIEW AND COMPLIANCE. (SCHEDULEC-B)
.4 SUBSTANTIAL COMPLETION WILL NOT BE CONSIDERED WITHOUTTHE SUBMISSION OF THE ABOVE DOCUMENTS.
.5 ALL THE ABOVE DOCUMENTS SHALL BE SUBMITTED TO THEELECTRICAL ENGINEER FOR FURTHER DISTRIBUTION AND FILES.
.6 IMMEDIATELY AFTER CONTRACT AWARD, CONTRACTOR SHALLSEND A LETTER TO THE ELECTRICAL ENGINEER CONFIRMINGRETAINMENT OF SEISMIC ENGINEER FOR THE SERVICES ASDESCRIBED IN THIS SPECIFICATION.
.7 SEISMIC ENGINEER SHALL BE A REGISTERED PROFESSIONALENGINEER IN THE ASSOCIATION OF PROFESSIONAL ENGINEERSAND GEOSCIENTISTS OF BRITISH COLUMBIA, AND SHALL HAVE AMINIMUM OF 2 YEARS EXPERIENCE IN THIS FIELD.
.8 SEISMIC ENGINEER SHALL HAVE ENGINEER'S PROFESSIONALLIABILITY INSURANCE, MINIMUM AS FOLLOWS:
$500,000.00 EACH LOSS
$1,000,000.00 PER POLICY PERMIT.
.9 THE CONTRACTOR SHALL COOPERATE WITH THE SEISMICENGINEER AND SHALL PROMPTLY SUPPLY SUCH INFORMATION,INCLUDING WEIGHTS OF EQUIPMENT AND BASE FRAME ORMOUNTING PLATE LAYOUTS, AS REQUESTED BY THE SEISMICENGINEER NECESSARY TO SUPPORT THE DESIGN AND DETAILSFOR SEISMIC RESTRAINT.
11.02
.1 THE FOLLOWING REQUIREMENTS ARE MINIMUM BUT ARE NOTEXHAUSTIVE. CONTRACTOR SHALL OBTAIN AND MEET DETAILSPECIFICATION AND REQUIREMENTS FROM SEISMIC ENGINEER. INNO CIRCUMSTANCES SHALL SEISMIC RESTRAINTS BE LESSSTRINGENT THAN AS REQUIRED BY THE FOLLOWINGSPECIFICATION AND SEISMIC ENGINEER.
.2 ACCEPTABLE ANCHOR BOLT MANUFACTURERS ARE HILTI, RAMSET,AND UCAN. OTHER MANUFACTURERS MAY BE USED SUBJECT TO
THE APPROVAL BY THE SEISMIC ENGINEER.
.3 SLACK CABLE RESTRAINTS SHALL UTILIZE EITHER GALVANIZED ORSTAINLESS STEEL STRANDED CABLE. THE INSTALLATION SHALLUSE CLAMPS, THIMBLES, SHACKLES AND OTHER ASSOCIATEDHARDWARE CORRECTLY SIZED FOR THE DIAMETER OF THE CABLESPECIFIED BY THE SEISMIC ENGINEER.
.4 SELECT VIBRATION ISOLATORS TO PROVIDE A NATURALFREQUENCY NOT GREATER THAN ONE THIRD OF THE EQUIPMENT'SLOWEST FORCING FREQUENCY.
.5 USE "LION" CHAIN, GALVANIZED STEEL WIRES OR AIRCRAFT CABLEFOR LUMINAIRE HANGERS.
.6 ALL SEISMIC RESTRAINT COMPONENTS EXPOSED TO THE WEATHERSHALL BE STAINLESS STEEL CONSTRUCTION OR PROTECTEDAGAINST CORROSION EITHER BY HOT-DIPPED GALVANIZING,TWO-COAT EPOXY PAINT SYSTEM, OR OTHER COATINGACCEPTABLE TO THE SEISMIC ENGINEER.
.7 NOTWITHSTANDING THE ABOVE, GAUGES OR SIZES SMALLER THANINDICATED BELOW WILL NOT BE ACCEPTED FOR SEISMICRESTRAINTS:
- #14 AWG WIRE
- 1/16" DIA AIRCRAFT CABLE
- #3 LION CHAIN
11.03
.1 PROVIDE SEISMIC RESTRAINTS INCLUDING ANCHOR BOLTS, SLACKCABLE BRACES AND MISCELLANEOUS FRAMING ANDCONNECTIONS.
.2 SEISMIC RESTRAINTS MAY BE OMITTED FROM THE FOLLOWINGINSTALLATIONS:
A) CONDUITS LESS THAN 1 1/4" DIAMETER.
.3 EQUIPMENT MANUFACTURER SHALL BE RESPONSIBLE FORENSURING THAT THE EQUIPMENT HAS ADEQUATE STRENGTH FORSEISMIC RESTRAINT AND ANCHORAGE OF THE EQUIPMENTFRAMING. MANUFACTURERS REPORT CONFIRMING THE ABOVESHALL BE SUBMITTED TO THE ELECTRICAL ENGINEER.
.4 PROVIDE TRANSVERSE AND LONGITUDINAL SEISMIC RESTRAINTANCHORAGE OR BRACING TO CABLE TRAYS, CONDUITS ANDBUSWAYS. ON VERTICAL BUS WAYS PROVIDE FOR LATERALRESTRAINT GUIDES AT EACH FLOOR PENETRATION AND SPACEDNOT MORE THAN 20' (REFER TO SEISMIC ENGINEER FORDIRECTIONS).
.5 SEISMIC RESTRAINTS SHALL BE INSTALLED AT LEAST 3" CLEARFROM OTHER EQUIPMENT, PIPING, DUCTS OR OTHERINSTALLATIONS.
.6 INSTALL SEISMIC RESTRAINT CABLE BRACES SO THAT THEY ARENOT VISIBLY SLACK. AT STEEL TRUSSES, CONNECT BRACES TOTOP CHORDS AT PANEL POINTS.
.7 FOR TRANSFORMERS, PROVIDE FOR VIBRATION ISOLATORS, ANDSEISMICALLY RATED SPRING ISOLATORS, OR USE SNUBBERS WITHRESILIENT BUSHINGS OR OTHER PROVISION, SUCH AS TO MAINTAINVIBRATION ISOLATION TOGETHER WITH SEISMIC RESTRAINT.
.8 FOR SUSPENDED EQUIPMENT, SUCH AS TRANSFORMERS, PROVIDECABLE OR RIGID BRACES TO RESTRAIN EQUIPMENT AGAINSTSEISMIC LOADS.
.9 PROVIDE SUB-FRAMES WHERE REQUIRED FOR ADEQUATESUPPORT OF THE EQUIPMENT FOR SEISMIC RESTRAINT ANDANCHORAGE TO THE BUILDING STRUCTURE.
.10 FOR LUMINAIRES INSTALLED IN SUSPENDED ACOUSTICAL, METALPAN OR COFFER CEILING SYSTEMS, INDEPENDENTLY SUPPORTLIGHT FIXTURES FROM STRUCTURE USING CABLES, WIRES ORCHAINS.
.11 FOR POWER GENERATION SYSTEMS, SEISMIC RESTRAINT SHALL BEINSTALLED ON GENERATOR SET, FUEL DAY TANK, BATTERY BANK,BATTERY CHARGER, MUFFLER, CONTROL PANELS AND CABINETS,AND ANY OTHER COMPONENT WHICH FORMS PART OF THE POWERGENERATION INSTALLATION.
.12 CO-ORDINATE WITH OTHER RELEVANT TRADES OR DIVISIONS FORTHE INSTALLATION OF HOUSEKEEPING PADS AS SPECIFIED ORSHOWN ON THE DRAWINGS.
.13 WHERE DRILLING OF THE STRUCTURE IS REQUIRED FORANCHORAGE DETAILS, THE DRILLING SHALL BE SUBJECT TO THEAPPROVAL OF THE STRUCTURAL ENGINEER.
12.00 DIV. 26 EXCLUSIONS
12.01 THE FOLLOWING WORK IS EXCLUDED FROM DIV. 26 SCOPE OFWORK BUT HAS TO BE DONE TO FACILITATE THE INSTALLATION OFELECTRICAL SYSTEMS AND/OR IS AFFECTED BY ELECTRICALINSTALLATIONS. THIS WORK HAS TO BE PERFORMED UNDER THEDIRECTION OF OTHER RELEVANT PROFESSIONAL SUCH AS ANARCHITECT, MECHANICAL, CIVIL, BUILDING ENVELOPE, ETC,ENGINEER. THIS WORK SHALL BE PERFORMED UNDER OTHERRELEVANT SPECIFICATION SECTIONS (OTHER THAN DIV. 26).CONTRACTOR SHALL COORDINATE DIV. 26 WORK WITH ALL OTHERRELEVANT WORK. FOR DIRECTIONS, GUIDANCE, SPECIFICATIONREGARDING THIS WORK, CONTRACTOR SHALL CONTACTRELEVANT PROFESSIONALS (NOT ELECTRICAL).
12.02 NON-EXHAUSTIVE LIST OF EXCLUSIONS:
.1 WATERPROOFING OF NON-ELECTRICAL COMPONENTS LIKEBUILDING ENVELOPE, WALLS, ROOF, ETC.
.2 X-RAYS FOR CUTTING, CORING, PATCHING.
.3 CONTROL WIRING UNLESS SPECIFIED IN THIS SECTION.
.4 ALL CIVIL CONCRETE, EXCAVATION OR BACKFILL WORK INCLUDINGSHORING AND BEDDING.
.5 COVERS FOR PULL PITS.
.6 PRECAST AND/OR CAST IN PLACE CONCRETE PRODUCTS SUCH ASPULLBOXES, LIGHT POLE BASES, TRANSFORMER CONCRETE PADS,ETC.
.7 DUCT DRAINAGE AND ASSOCIATED BACKWATER VALVES.
.8 BACKING.
.9 PAINTING UNLESS SPECIFIED IN THIS SECTION.
.10 FIRE RATED DRYWALL ENCLOSURES FOR PANELBOARD AND LIGHTFIXTURES.
.11 CUTTING, PATCHING OR CORING.
.12 TEMPORARY LIGHTING UNLESS SPECIFICALLY DETAILED AS PARTOF DIV. 26 WORK.
13.00 RENOVATION AREA SPECIFICATIONS
.01 CONTRACTOR IS TO ENSURE THAT A MINIMUM OF DISRUPTIONOCCURS TO THE OWNERS PRIMARY BUSINESS DURING THEIRNORMAL HOURS OF OPERATION. THIS MAY INVOLVE THECONTRACTORS WORK BEING PERFORMED ON EVENINGS,WEEKENDS, AND/OR HOLIDAYS. THE CONTRACTOR SHALL INCLUDEALL COSTS OF THIS PROVISION IN THEIR BASE TENDER QUOTE. NOALLOWANCE WILL BE SUBSEQUENTLY BE MADE FOR FAILURE TOINCLUDE THESE COSTS IN BASE TENDER QUOTE.
.02 CONTRACTOR SHALL REWIRE, EXTEND WIRES, CONDUITS, ETC. ORINSTALL NEW FOR ANY RELOCATED ELECTRICAL DEVICES ASSHOWN ON THE DRAWINGS AND/OR AS REQUIRED.
.03 ALL ELECTRICAL DEVICES SHOWN ON THE DRAWINGS AND/OR ASREQUIRED SHALL BE NEW UNLESS OTHERWISE NOTED.
.04 ALL MODIFIED/NEW ELECTRICAL SYSTEMS SHALL BE FULLYOPERATIONAL AFTER RENOVATION IS COMPLETE AND BEACCEPTED BY THE CONSULTANT AND OWNER.
.05 ALL REMOVED AND UNUSED ELECTRICAL DEVICES FROM THERENOVATED AREAS SHALL BE TURNED OVER TO OWNER UNLESSOTHERWISE NOTED. INTERM STORAGE LOCATION OF THESEDEVICES SHALL BE COORDINATED WITH THE OWNER AND STOREDSECURELY TO PREVENT DAMAGE.
.06 CONTRACTOR SHALL RELOCATE, REWIRE, OR REROUTE ALL WIRINGWHICH PASSES THROUGH RENOVATED AREAS TO ENSURE PROPEROPERATION OF ALL ELECTRICAL SYSTEMS OUTSIDE OF RENOVATEDAREAS.
.07 ANY FIXTURES, WIRING DEVICES, ETC. DAMAGED DURING ANDAFTER REMOVAL SHALL BE REPLACED WITH NEW APPROVEDEQUIPMENT AT CONTRACTOR'S COST.
.08 CONTRACTOR IS RESPONSIBLE FOR ADEQUATE PROTECTION OFEQUIPMENT, FURNITURE, ETC. (PLASTIC COVERS, MOVEMENT OFOWNER FURNITURE, ETC.) DURING THE EXECUTION OF THE WORK.
.09 CONTRACTOR IS RESPONSIBLE FOR CLEANING UP THE WORK AREAEACH DAY BEFORE LEAVING THE JOB SITE.
.10 ALL MATERIALS SHALL BE SUPPLIED AND INSTALLED AS SPECIFIEDAND/OR SHOWN ON THE DRAWINGS.
.11 CONTRACTOR TO CONFIRM ALL LOCATIONS OF EXISTINGEQUIPMENT, WIRING, CIRCUIT NUMBERS, ETC.
.12 ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALLCUTTING, PATCHING AND PAINT FOR ALL AREAS AFFECTED BY THERENOVATION. FINAL FINISHES SHALL MATCH EXISTING AND ISSUBJECT TO FINAL APPROVAL BY THE CITY. SHOULD THE CITYASSESS THAT THE COLORS OR FINISHES DO NOT MATCH, THECONTRACTOR WILL BE REQUIRED TO PAINT ENTIRE WALL AND/ORCEILING.
14.00 FIELD REVIEW DEFINITION
.01 FIELD REVIEW ARE :
- CONDUCTED SPECIFICALLY AND ONLY FOR THE SCOPE OF WORKFOR WHICH THE CONSULTANT IS RESPONSIBLE;
- A REVIEW CONDUCTED AT THE SITE OF THE IMPLEMENTATION ORCONSTRUCTION OF THE ENGINEERING WORK;
- CONDUCTED AT INTERVALS APPROPRIATE TO THE STAGE OF THECONSTRUCTION/IMPLEMENTATION;
- PERFORMED BY THE CONSULTANT WHEN CONSIDERED AT THECONSULTANT'S PROFESSIONAL DISCRETION TO BE NECESSARYTO BECOME FAMILIAR WITH THE PROGRESS AND QUALITY OF THEWORK;
- TO DETERMINE THAT THE WORK IS IN GENERAL CONFORMITYWITH THE CONSTRUCTION CONTRACT DOCUMENTS; AND
- RECORDED IN WRITING AND COMMUNICATED TO THE CLIENT, ANDCONTRACTOR.
.02 FIELD REVIEWS DO NOT:
- PROVIDE SUPERVISION OF THE IMPLEMENTATION OR CONSTRUCTIONWORK;
- DIRECT OR HAVE CONTROL OVER THE CONTRACTOR'S WORK;
- HAVE ANY RESPONSIBILITY FOR THE CONSTRUCTION MEANS,METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES SELECTEDBY THE CONTRACTOR NOR FOR THE CONTRACTOR'S SAFETYPRECAUTIONS OR PROGRAMS IN CONNECTION WITH THE WORK.(THESE RIGHTS AND RESPONSIBILITIES ARE SOLELY THOSE OF THECONTRACTOR IN ACCORDANCE WITH THE CONTRACT DOCUMENTS);
- GUARANTEE THAT THE PERFORMANCE OF THE CONTRACTOR IS INACCORDANCE WITH THE CONTRACT DOCUMENTS OR ANYAPPLICABLE LAWS, CODES, RULES OR REGULATIONS;
- GUARANTEE THAT ALL DEFICIENT WORK WILL BE IDENTIFIED BY THEFIELD REVIEWER (THE REVIEWER MAY REJECT NON-CONFORMINGWORK, BUT WILL LEAVE THE MEANS AND METHODS FOR ACHIEVINGWHAT IS REQUIRED TO THE CONTRACTOR OR OTHERS WHO ARETASKED WITH IMPLEMENTING OR CONSTRUCTING THE WORK); AND,
- INSPECT THE WORK OR SAFETY AT A CONTRACTOR-CONTROLLEDSITE OR A SITE MANAGED BY OTHERS, AND DOES NOT REVIEW THESAFETY PROGRAMS.
DIV. 26 SPECIFICATION
PROJECT NO.
DRAWING TITLE:DATE
CHECKED BYDRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
SEAL:
CONSULTANT:
7268
FEB. 07, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.G.A.G.
DESCRIPTIONDATEREV.
650-2700 PRODUCTION WAY
BURNABY, BC V5A 4X1
PH.604.676.9545
ACUMENENGINEERING.CA
INFORMATION CONTAINED ON THESE DOCUMENTS IS PART OF ACUMENENGINEERING LTD. INSTRUMENTS OF SERVICE, AND ACUMEN ENGINEERING LTD.
SHALL RETAIN OWNERSHIP THEREOF. SUCH INFORMATION SHALL NOT BE USED FORANY PURPOSE OTHER THAN FOR THE CONSTRUCTION/IMPLEMENTATION OF THE
REFERENCED PROJECT. ANY OTHER USE, REUSE OR MODIFICATION OF THEDOCUMENTS WITHOUT THE ACUMEN ENGINEERING LTD. PRIOR WRITTEN CONSENT
WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO THE CONSULTANT. PAYMENT OF ALL SUMS DUE TO ACUMEN
ENGINEERING LTD. UP TO THE DATE OF THE INTENDED USE OF THIS DRAWING IS ACONDITION PRECEDENT TO THE USE THEREOF.
ELECTRICAL
SPECIFICATION
E-5
2019.02.26 ISSUED FOR COORDINATION1.2019.03.20 ISSUED FOR TENDER2.
ROOM TEMPERATURE SENSOR
STRAINER
BACKFLOW PREVENTOR (BFP)
BALANCING VALVE
THERMOMETER
PUMP
AIR VOLUME (L/s)
GRILLE TYPE
NECK / GRILLE SIZE
PRESSURE SENSOR
FLOW SWITCH
EQUIPMENT / FIXTURE TYPE
DRAWING REVISION
DETAIL NUMBER
DRAWING NUMBER
V
SANITARY SEWER ABOVE GRADE
SANITARY VENT
SANITARY SEWER BELOW GRADE
DOMESTIC HOT WATER RECIRC. (DHWR)
DOMESTIC HOT WATER (DHW)
DOMESTIC COLD WATER (DCW)
EXHAUST AIR DUCT DOWN
EXHAUST AIR DUCT UP
RETURN AIR DUCT UP
RETURN AIR DUCT DOWN
SUPPLY OR OUTDOOR AIR DUCT DOWN
SUPPLY OR OUTDOOR AIR DUCT UP
DIRECTION OF FLOW
PIPE DROP
PIPE RISE
PIPE TEE UP
PIPE CLEAN-OUT
ISOLATION VALVE (NORMALLY OPEN)
CHECK VALVE
2-WAY CONTROL VALVE
ISOLATION VALVE (NORMALLY CLOSED)
PIPE UNION
SAN
GENERAL NOTE
SAN
PIPING SYSTEM MONITORING
DUCTWORK
EQUIPMENT TAGS
DUCT OR PIPE CAP-OFF
RETURN OR EXHAUST AIR GRILLE
FIRE DAMPER - HORIZONTAL (FD)
FIRE DAMPER - VERTICAL (FD)
BALANCING DAMPER (BD)
ACOUSTIC INSULATION
TURNING VANES
DEMOLITION EXISTING NEW
V
SAN
SAN
V
SAN
SAN
NC
NO
DEMOLITION EXISTING NEW
PIPE TEE DOWN
FD
FD
FITTINGS AND VALVES
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CHWS
CHWR
CONDENSATE DRAINC
CHWS
CHWR
C
CHWS
CHWR
C
SYMBOL SCHEDULE
T
FS
PIPE TEMPERATURE SENSOR
T
NC
NO
NC
NO
T
FS
T
P
-
M-
-
-
-
-
-
-
-
M-
-
-
-
-
-
-
FD
FD
FD
FD
T
FS
T
P
-
M-
-
-
-
-
-
-
P
MECHANICAL RENOVATION NOTES:
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE
DRAWINGS, DIAGRAMS, SCHEMATICS AND AS DESCRIBED IN THE
SPECIFICATIONS.
2. THE MECHANICAL PLANS ARE DIAGRAMMATIC IN NATURE AND DO NOT
ATTEMPT TO SHOW ALL REQUIRED OFFSETS. REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS FOR ADDITIONAL CONSTRUCTION DETAILS.
3. COORDINATE THE DRAWINGS WITH THE SPECIFICATIONS AND IN CASES
WHERE CONFLICTS OCCUR THE MOST STRINGENT REQUIREMENT SHALL
APPLY.
4. CONTRACTOR TO COORDINATE ALL MECHANICAL WORK WITH THAT OF
OTHER TRADES TO ENSURE PROPER AND ADEQUATE INTERFACE WITH
THE WORK OUTLINED FOR THIS PROJECT.
5. CONTRACTOR TO PROVIDE NEC (NATIONAL ELECTRICAL CODE)
CLEARANCE HORIZONTAL AND VERTICAL REQUIREMENTS FOR ALL
INSTALLED EQUIPMENT. OFFSET MECHANICAL WORK AS REQUIRED TO
MEET THIS REQUIREMENT.
8. REFER TO PRE-PROJECT HAZARDOUS MATERIAL'S ASSESSMENT REPORT
FOR INFORMATION REGARDING ASBESTOS ABATMENT.
9. MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEATING
OR COOLING DURING THE CONSTRUCTION PROCESS. A WRITTEN LETTER
FROM THE OWNER IS REQUIRED TO DO SO.
10. ALL DUCTWORK SIZES ARE SHOWN AS INSIDE CLEAR. ADD APPROPRIATE
DIMENSION FOR INSULATION OR DUCT LINER TO OBTAIN "TOTAL DUCT
SIZE".
11. MAXIMUM FLEXIBLE DUCT LENGTH SHALL BE NO LONGER THAN 3' UNLESS
OTHERWISE NOTED FOR THE SPECIFIC APPLICATION.
12. INSTALL ALL MECHANICAL WORK AS HIGH AS POSSIBLE TIGHT TO
STRUCTURE.
13. CONTRACTOR TO ALLOW AND PROVIDE FOR METAL DUCTWORK
TRANSITIONS BETWEEN ALL EQUIPMENT AND DUCT CONNECTIONS.
14. PROVIDE DIFFUSERS AND GRILLE COMPATIBLE WITH ARCHITECTURAL
CEILING TYPES. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING
TYPES.
15. COORDINATE EXACT LOCATIONS OF ALL ROOM THERMOSTATS AND/OR
ROOM TEMPERATURE SENSORS WITH THE DESIGN ARCHITECT BEFORE
FINAL INSTALLATION.
16. CONTRACTOR TO SUPPLY AND INSTALL VOLUME DAMPER FOR EACH
SUPPLY, RETURN AND EXHAUST DUCTWORK RUN WITH TWO OR MORE
OPENINGS ASSOCIATED WITH THE BRANCH. REFER TO THE DRAWINGS
FOR ADDITIONAL VOLUME DAMPERS LOCATIONS AND REQUIREMENTS.
17. BALANCING TO BE DONE BY BASE BUILDING APPROVED BALANCING
AGENCIES. LIST. PROVIDE 2 COPIES OF BALANCE REPORT TO OWNER AND
1 COPY TO ENGINEER. WHEN BALANCING THE AIR FLOW SYSTEM THE
VOLUME DAMPER ON THE DIFFUSER IS ONLY TO BALANCE A MAXIMUM OF
10% OF THE AIR FLOW RATE. THE REMAINING AIR FLOW IS TO BE
BALANCED UPSTREAM OF THE DIFFUSER ON THE BRANCH VOLUME
DAMPERS.
18. PROVIDE 1" THICK DUCTWORK LINER ON ALL TRANSFER AIR DUCTS.
19. REPORT TO THE ENGINEER ANY DISCREPANCIES WHICH WILL PREVENT
THE WORK FROM BEING INSTALLED AS SHOWN.
ON-SITE SERVICES (NEW)
PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL EXERCISE
PROPER PRECAUTIONS TO VERIFY THE ROUTING, INVERT LEVELS, AND
SLOPES SHOWN ON THE DRAWING AND BE RESPONSIBLE FOR ERRORS
AND ALL EXTRA COSTS OF EXTRA WORK RESULTING FROM FAILURE TO
EXERCISE SUCH PRECAUTIONS.
ONSITE SERVICES (EXISTING)
PRIOR TO COMMENCING WORK THE CONTRACTOR SHALL LOCATE AND
EXPOSE ANY UTILITY SERVICES CROSSING THE ROUTING OF NEW
SERVICES. ENSURE THAT THESE SERVICES REMAIN OPERATIONAL AND
ARE NOT DAMAGED DURING OPERATIONS. RECORD THE LOCATION AND
TYPE OF SERVICE.
20. CONTRACTOR TO RETAIN AND PAY FOR A SEISMIC ENGINEER REGISTERED
WITH ENGINEERS AND GEOSCIENTISTS OF BRITISH COLUMBIA TO DESIGN
AND UNDERTAKE FIELD REVIEW TO SEISMIC RESTRAINT OF ALL
MECHANICAL EQUIPMENT. PROVIDE SIGNED AND SEALED DRAWINGS AND
SCHEDULES.
21. FOR EQUIPMENT CONCRETE SLABS ON GRADE, PROVIDE, 6" GALVANIZED
STEEL MESH REINFORCED CONCRETE SLAB, 6" GRAVEL FILL COMPACTED
TO 95% DENSITY OVER COMPACTED SUB BASE. ALL EXCAVATION TO BE
COMPLETED BY HAND UNDER SUPERVISION OF THE CITY ARBORIST. AS
REQUIRED BY CITY OF NEW WESTMINSTER.
22. INSTALLATION OF MECHANICAL CURBS AND PENETRATIONS TO BE
UNDERTAKEN BY A RCABC CERTIFIED ROOFING CONTRACTOR. AS
REQUIRED BY CITY OF NEW WESTMINSTER.
23. CONTRACTOR TO ALLOW FOR TRANSPORTATION OF OWNER SUPPLIED
EQUIPMENT FROM CITY OF NEW WESTMINSTER STORAGE YARD TO SITE.
24. ALL EXTERIOR REFRIGERANT LINES TO BE FINISHED IN PVC JACKETING,
REFER TO SPEC.
25. CONTRACTOR TO NOTE ALL MAJOR MECHANICAL EQUIPMENT FOR
PROJECT HAS BEEN PURCHASED BY OWNER AND ASSIGNED TO THE
PROJECT. PURCHASING INVOICE HAS BEEN ATTACHED FOR CONTRACTOR
CLARIFICATION ON PURCHASED EQUIPMENT, ACCESSORIES & RELATED
COSTS. CONTRACTOR TO NOTE THAT THE EQUIPMENT WARRANTY WILL BE
CARRIED BY CONTRACTOR, THEREFORE ANY ADDITIONAL COST FOR
WARRANTY SHALL BE INCLUDED.
1. CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND VERIFYING ACTUAL ONSITE CONDITIONS AND EQUIPMENT LOCATIONS
PRIOR TO ANY AND ALL DEMOLITION WORK AND/OR EQUIPMENT REMOVAL.
2. CONTRACTOR TO INCLUDE ALL CUTTING AND PATCHING THAT IS REQUIRED TO INSTALL ALL NEW MECHANICAL SYSTEMS AS
REQUIRED TO MEET THE SITE CONDITIONS AS SHOWN ON THE DRAWINGS. PATCHING SHALL MEET THE AESTHETIC
CONDITIONS WHICH WAS THE CONDITION PRIOR TO ANY CUTTING BEING PREFORMED. ALL FINISHING TO MATCH EXISTING AND
COMPLY WITH FIRE RESISTANCE RATED ASSEMBLIES. REFINISH ENTIRE WALL OR CEILING SURFACES WITH FINISHES TO MATCH
EXISTING.
3. CONTRACTOR TO PROPERLY SEAL AND REPAIR ANY AND ALL DAMAGE THAT IS A RESULT OF REMOVAL OR DEMOLITION OF
MECHANICAL EQUIPMENT. THIS INCLUDES BUT IS NOT LIMITED TO WALL, DOOR, CEILINGS, ECT.
4. THE EXISTING FACILITIES MECHANICAL SYSTEMS SHALL REMAIN OPERATIONAL DURING THE CONSTRUCTION AND
RENOVATION PERIOD. CONTRACTOR TO COORDINATE CONSTRUCTION ACTIVITIES AND PHASING WITH OWNER TO MINIMIZE
DISRUPTIONS TO OWNERS OPERATIONS AND ACCESS, AND TO ENSURE SAFETY OF THE USERS. PROVIDE ALL MEASURES
REQUIRED TO PREVENT HAZARDS TO PEOPLE AND DAMAGE TO ITEMS REMAINING INCLUDING BUT NOT LIMITED TO DAMAGE
FROM DUST AND HEAT.
5. DURING REMOVAL OF ITEMS SO INDICATED, CAUTION SHOULD BE USED TO PREVENT DAMAGE TO ANY EQUIPMENT HAVING
SALVAGE VALUE. ALL REUSABLE SALVAGED MATERIAL SHALL REMAIN THE PROPERTY OF THE OWNER AND BE RETAINED FOR
THEIR INSPECTION. ONLY ITEMS AGREED BY THE OWNER SHALL BE DISPOSED OF BY THE CONTRACTOR.
6. CONTRACTOR IS TO UNINSTALL AND STORE ALL SUPPLY AIR DIFFUSERS UNTIL INSTALLATION IN NEW LOCATION.
7. GIVE BASE BUILDING A MINIMUM 24 HOURS NOTICE OF ANY SERVICE SHUTDOWN.
8. ALL PENETRATIONS THROUGH PARTITIONS AND FIRE RATED ASSEMBLIES ARE TO BE FIRE STOPPED WITH A ULC APPROVED
FIRE STOPPING DETAIL. ALL OPENINGS THROUGH FIRE RATED CEILING AND WALL ASSEMBLIES TO BE CONSTRUCTED TO
MAINTAIN THE FIRE RESISTANCE RATING OF THE ASSEMBLY. AS REQUIRED BY CITY OF NEW WESTMINSTER.
GENERAL RENOVATION NOTES:
UPRIGHT SPRINKLER HEAD
PENDANT SPRINKLER HEAD
FIRE EXTINGUISHER
FIRE PROTECTION
FEFEFE
620 EIGHTH STREET
NEW WESTMINSTER BC, CANADA
V3M 3S2
CIVIC ADDRESS
SCALE:
1
M0.01
NTS
SITE PLAN
PROJECT SCOPE OF WORK
AREA
TRUE NORTH
MECHANICAL DRAWING LIST
DRAWINGS NO.
M0.01
M0.02
M0.03
M0.04
M0.05
M1.01
M1.02
M1.03
M1.04
M1.05
M1.06
M1.07
M1.08
M2.01
M3.01
DESCRIPTION
DRAWING NOTES AND SYMBOL SCHEDULE
MECHANICAL SCHEDULES
HVAC ROOF PLAN
HVAC LEVEL 1 PLAN
HVAC BASEMENT PLAN
HVAC WILLOW ROOM RENOVATION PLAN
HVAC MAPLE ROOM RENOVATION PLAN
HVAC KITCHEN AREA RENOVATION PLAN
HVAC SPRUCE ROOM RENOVATION PLAN
HVAC OFFICE AREA RENOVATION PLAN
HVAC ROOF NORTH RENOVATION PLAN
HVAC ROOF SOUTH RENOVATION PLAN
HVAC CEDAR, ARBUTUS & BIRCH PLAN
MECHANICAL DETAILS
MECHANICAL SPECIFICATION
SCALE
N.T.S.
N.T.S.
1'-0" = 3/32"
1'-0" = 3/32"
1'-0" = 3/32"
1'-0" = 1/4"
1'-0" = 1/4"
1'-0" = 1/4"
1'-0" = 1/4"
1'-0" = 1/4"
1'-0" = 1/4"
1'-0" = 1/4"
1'-0" = 1/4"
N.T.S.
N.T.S.
DRAWING NOTES AND SYMBOL SCHEDULE
M0.01
AS NOTED
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
MECHANICAL MOTORLIST
UNIT NUMBER
CU-1
CU-2
CU-3
CU-4
CU-5
AC-6
AC-7
AC-8
AC-9
AC-10
AC-11
HV-1
HV-2
HV-3
HRV-1
HRV-2
HRV-3
EF-1
FF-1
QTY
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
SUPPLIER / INSTALL / WIRE CODES:
M = MECHANICAL
E = ELECTRICAL
G = GENERAL CONTRACTOR
S = SUPPLIED BY
I = INSTALLED BY
C = CONNECTED BY
STARTER CODES:
MAN = MANUAL STARTER
HOA = MAGNETIC STARTER W/ HAND/OFF/AUTO
SWITCH W/ AUX. CONTACTS
MAG = MAGNETIC STARTER C/W AUX STATUS CONTACTS
MRR = MOTOR RATED RELAY, 24 VAC COIL
& MOTOR PROTECTION SWITCH
PCS = PACKAGED CONTROL SYSTEM
VFD = VARIABLE FREQUENCY DRIVE
RVS = REDUCED VOLTAGE STARTER
WS = WALL SWITCH
CP = CONTROL PANEL
EMERGENCY POWER CODES:
VP = VITAL POWER
DVP = DELAYED VITAL POWER
CP = CONDITIONAL POWER
NP = NORMAL POWER
UNIT DESCRIPTION
AIR CONDITIONING UNIT
AIR CONDITIONING UNIT
AIR CONDITIONING UNIT
AIR CONDITIONING UNIT
AIR CONDITIONING UNIT
INDOOR EVAPORATOR UNIT
INDOOR EVAPORATOR UNIT
INDOOR EVAPORATOR UNIT
INDOOR EVAPORATOR UNIT
INDOOR EVAPORATOR UNIT
INDOOR EVAPORATOR UNIT
AIR HANDLING UNIT
AIR HANDLING UNIT
AIR HANDLING UNIT
HEAT RECOVERY VENTILATOR
HEAT RECOVERY VENTILATOR
HEAT RECOVERY VENTILATOR
EXHAUST FAN
FORCE FLOW HEATER
UNIT LOCATION
KITCHEN
OFFICE
ADJACENT TO SPRUCE ROOM
ADJACENT TO WILLOW ROOM
ADJACENT TO MAPLE ROOM
MAPLE ROOM
MAPLE ROOM
MAPLE ROOM
WILLOW ROOM
WILLOW ROOM
WILLOW ROOM
ROOF
ROOF
ROOF
MANAGERS OFFICE
PROGRAMMERS OFFICE
PEER COUNSEL OFFICE
ELECTRICAL ROOM
ENTRANCE
CONTROL DEVICE CODES:
AQUA = PUMP CONTROLLED BY AQUASTAT
BMS = BLDG MANAGEMENT SYSTEM
ES = END SWITCH
ET = LINE VOLTAGE T'STAT
FA = FIRE ALARM
FAP = FIRE ALARM PANEL
FS = FLOW SWITCH
GS = GAS SENSOR
H = HUMIDITY SENSOR
I = INTERLOCK, SEE NOTES
LIGHT = WIRED TO LIGHT SWITCH
LS = LEVEL SWITCH
OS = OCCUPANT SENSOR
PS = PRESSURE SWITCH
R. STAT = REVERSE ACTING THERMOSTAT
TC = TIME CLOCK
T = LOW VOLTAGE T'STAT OR SENSOR
TS = TAMPER SWITCH
VS = VARIABLE SPEED SWITCH
WS = WALL SWITCH
ELECTRICAL LOAD
10.3 MCA
16.9 MCA
23 MCA
29 MCA
29 MCA
0.36 FLA
0.36 FLA
0.30 FLA
0.36 FLA
0.36 FLA
0.30 FLA
112 MCA
45 MCA
61 MCA
100 W
100 W
100 W
16W
2000 W
ELECTRICAL LOAD CODES:
BHP = BREAK HORSEPOWER
FLA = UNIT FULL LOAD AMPS
HP = UNIT OR MOTOR HORSE POWER
PH = POWER PHASE
MCA = MINIMUM CIRCUIT AMPS
VOLT = REQUIRED SUPPLY VOLTAGE
MISCELLANEOUS CODES:
FFCP = FIRE FIGHTERS CONTROL PANEL
FRAC = FRACTIONAL HORSEPOWER
INT = INTEGRAL PART OF UNIT
VOLT
208
208
208
208
208
208
208
208
208
208
208
208
208
208
120
120
120
120
208
PH
1
1
1
1
1
1
1
1
1
1
1
3
3
3
1
1
1
1
1
S
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
EQUIPMENT
I
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
C
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
STARTER
S
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
GENERAL NOTES:
A. ALL FIRE ALARM DEVICES WIRED BY ELECTRICAL
B. CONTROL PANELS ARE SHIPPED LOOSE & REQUIRE FIELD WIRING
C. PCS EQUIPMENT REQUIRES SINGLE SOURCE POWER CONNECTION, UNLESS
NOTED OTHERWISE
D. CP, VFD EQUIPMENT REQUIRES POWER WIRING TO AND FROM CONTROL PANEL
TO CONTROLLED EQUIPMENT
NOTES:
1.
2.
3.
4.
I
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SINGLE POINT POWER CONNECTION.
INDOOR UNIT TO BE POWERED BY OUTDOOR UNIT.
REFER TO MANUFACTURER'S CUT SHEETS FOR FURTHER DETAILS
CONTROL BY REVERSE ACTING THERMOSTAT
C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TYPE
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
S
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
DISCONNECT
I
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
C
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
CONTROL
S
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
-
I
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
-
C
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
-
TYPE
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
INT
DDC
DDC
DDC
INT
INT
INT
INT
INT
NOTES
1,2,3
1,2,3
1,2,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3,4
1,3
HEAT RECOVERY VENTILATOR
EQUIPMENT TAG
HRV-1 (A/B)
HRV-2 (A/B)
HRV-3 (A/B)
NOTES:
1
2
4
QTY
1
1
1
C/W 12DC POWER SUPPLY
PROVIDE RAIN COVER FOR OUTDOOR PENETRATION
C/W SMART COMFORT CONTROLLER
SERVICE
MANAGER OFFICE
PROGRAMMER OFFICE
PEER COUNSEL OFFICE
LOCATION
MANAGER OFFICE
PROGRAMMER OFFICE
PEER COUNSEL OFFICE
MANUFACTURER
LUNOS
LUNOS
LUNOS
MODEL
E^2
E^2
E^2
AIRFLOW
CFM
25
25
25
ELEC
(V/PH/HZ)
120/1/60
120/1/60
120/1/60
NOTES
ALL
ALL
ALL
UNIT HEATER (ELECTRIC)
EQUIPMENT
TAG
FF-1
NOTES:
1
QTY
1
INTEGRATED THERMOSTAT
LOCATION
ENTRANCE CEILING
MANUFACTURER
QMARK
TYPE
FORCE FLOW
MOUNTING
TYPE
SURFACE MOUNT
MODEL
CDF-548
AIR FLOW
(CFM)
300
HGT CAP
(MBH)
6.8
ELEC
(V/PH/CYC)
208/1/60
NOTES
ALL
FANS
EQUIPMENT
TAG
EF-1
NOTES:
1
2
3
QTY
1
ACOUSTIC LINED CABINET.
REFER TO MOTORLIST FOR ELECTRICAL REQUIREMENTS
CONTROLLED BY REVERSE ACTING THERMOSTAT
SERVICE
ELECTRICAL ROOM
LOCATION
ELECTRICAL ROOM
TYPE
EXHAUST
MANUFACTURER
GREENHECK
MODEL
SP-A70
AIR FLOW
(CFM)
70
E. S. P.
(IN.WG)
0.1
FAN
(RPM)
-
DRIVE
TYPE
DIRECT
SOUND LEVEL
(SONES)
0.3
WEIGHT
(LBS)
12.0
NOTES
ALL
DIFFUSERS AND GRILLES
EQUIPMENT
TAG
S-1
R-1
L-1
NOTES:
DESCRIPTION/TYPE
CEILING SUPPLY GRILLE
SURFACE MOUNTED RETURN GRILLE
EXTERIOR LOUVRE
1. LOUVRE SHALL HAVE MINIMUM 50% FREE AREA.
2. LOUVRE FINISH TO ARCHITECT'S SELECTION
3. COMPLETE WITH 12MM (1/2") BIRD SCREEN.
4. COLOUR OF PRODUCT TO BE SELECTED BY THE ARCHITECT DURING THE SHOP DRAWINGS SUBMITTAL PROCESS.
5. PROVIDE DIFFUSERS AND GRILLES WITH BORDER STYLES THAT ARE COMPATIBLE
WITH ADJACENT WALLS AND CEILING SYSTEMS. REFER TO ARCHITECTURAL DRAWINGS
MANUFACTURER
EH PRICE
EH PRICE
EH PRICE
MODEL NUMBER
520
535
DE439
INSTALLATION
SURFACE MOUNT
SURFACE MOUNT
EXTERIOR WALL
NOTES
5
5
1,2,3,4
AIR HANDLING UNIT
TAG
QUANTITY
LOCATION
MANUFACTUER
SYSTEM TYPE
MODEL
SUPPLY FAN
NORMAL VOLUME (CFM)
MINIMUM OUTDOOR AIR (CFM)
EXTERNAL STATIC (IN. WG)
FAN TYPE
BREAK HORSE POWER (HP)
HEATING
HEATING TYPE
CAPACITY (MBH)
EAT (DEG. F)
LAT (DEG. F)
PRESSURE (NATURAL GAS)
STAGES
COOLING
SENSIBLE CAPACITY (MBH)
TOTAL CAPACITY (MBH)
STAGES
EAT DB (DEG. F)
EAT WB (DEG. F)
LAT DB (DEG. F)
LAT WB (DEG. F)
ELECTRICAL
POWER (VOLT/PHASE/HZ)
MCA (A)
FILTERS
MAIN FILTER
DIMENSIONS
LXWXH (INCH)
WEIGHT
EXISTING UNIT (LBS)
NEW UNIT (LBS)
NOTES
NOTES:
1
2
3
4
5
HV-1
1
SOUTH ROOF
TRANE
RTU
YSH240G3RV-01
8,000
975
1.5
CENTRIFUGAL
7.6
NATURAL GAS
280.0
70.0
102.0
2.5
MODULATING 2.5:1
200
255
2
80
67
60
58
208/3/60
112.0
20"x25"x2"
10.14' x 7.02' x 4.68
2,650
2,388
ALL
100% ECONOMIZER CAPABILITY
SINGLE POINT POWER CONNECTION TO UNIT
THE UNIT WILL BE COMPLETED WITH A 24V TERMINAL STRIP FOR DDC CONNECTIONS
STAINLESS STEEL HEAT EXCHANGERS FOR THE GAS SECTION
SEE ATTACHED CUT SHEETS AND SPECIFICATIONS FOR FURTHER INFORMATION
HV-2
1
SOUTH ROOF
TRANE
RTU
YSC092H3-ZA-C1
3,000
225
1.5
CENTRIFUGAL
2.6
NATURAL GAS
160.0
70.0
119.0
4.5
2.0
74
94
2
80
67
60
58
208/3/60
45.0
20"x25"x2"
4.44' x 7.39' x 3.91'
2,600
1,182
ALL
HV-3
1
NORTH ROOF
TRANE
RTU
YSD150G3RV-D0
5,000
560
1.0
CENTRIFUGAL
3.7
NATURAL GAS
280.0
70.0
121.0
2.5
MODULATING 2.5:1
120
148
2
80
67
60
58
208/3/60
61.0
20"x25"x2" / 20"x20"x2"
8.89' x 5.90' x 4.35'
1,815
1,864
ALL
AIR CONDITIONING UNIT
EQUIPMENT TAG
EVAPORATOR
AC-1
AC-2
AC-3
AC-4
AC-5
AC-6
AC-7
AC-8
AC-9
AC-10
AC-11
NOTES: EVAP = INDOOR UNIT
1 AC-1 TO AC-5 TO BE POWERED BY CONDENSING UNIT. AC-6 TO 11 TO BE CONNECTED TO SEPARATE FEED
2 WIRED WALL MOUNTED REMOTE CONTROLLER
3 PROVIDE PACKAGED CONDENSATE PUMP.
4 REFRIGERANT AND SUCTION LINES SIZE BY MANUFACTURER.
5 INDOOR UNIT POWER BY OUTDOOR UNIT
6 PROVIDE MOUNTING BASE FOR OUTDOOR UNIT ON DURA BLOCKS
7 C/W ENABLE + DISABLE INTERFACE BOARD.
8 SEE ATTACHED CUT SHEETS AND SPECIFICATIONS FOR FURTHER INFORMATION
CONDENSER
CU-2
CU-2
CU-2
CU-1
CU-3
CU-5
CU-5
CU-5
CU-4
CU-4
CU-4
QTY
1
1
1
1
1
1
1
1
1
1
1
LOCATION
EVAPORATOR
MANAGER OFFICE
PROGRAMMER OFFICE
PEER COUNSEL OFFICE
KITCHEN
SPRUCE ROOM CEILING
MAPLE ROOM
MAPLE ROOM
MAPLE ROOM
WILLOW ROOM
WILLOW ROOM
WILLOW ROOM
TYPE
WALL MOUNT
WALL MOUNT
WALL MOUNT
WALL MOUNT
FAN COIL
WALL MOUNT
WALL MOUNT
WALL MOUNT
WALL MOUNT
WALL MOUNT
WALL MOUNT
MANUFACTURER
TRANE-SAMSUNG
TRANE-SAMSUNG
TRANE-SAMSUNG
TRANE-SAMSUNG
TRANE-SAMSUNG
TRANE-SAMSUNG
TRANE-SAMSUNG
TRANE-SAMSUNG
TRANE-SAMSUNG
TRANE-SAMSUNG
TRANE-SAMSUNG
EVAP. MODEL
AJ007JNADCHAA
AJ007JNADCHAA
AJ007JNADCHAA
AR12KSWSJWKNCV
AC030MNHDCH/AA
AM018FNTDCH
AM018FNTDCH
AM012FNTDCH
AM018FNTDCH
AM018FNTDCH
AM018FNTDCH
TOTAL CLG CAP (MBH)
7
7
7
13.6
30
18
18
12
18
18
18
EFFY(SEER)
18
18
18
22.0
18.4
18.9
18.9
18.9
18.9
18.9
18.9
COND. MODEL NO.
AJ024JCJ3CH/AA
AJ024JCJ3CH/AA
AJ024JCJ3CH/AA
AR12KSWSJWKXCV
AC030JXADCH/AA
AM048NXMDCR/AA
AM048NXMDCR/AA
AM048NXMDCR/AA
AM048NXMDCR/AA
AM048NXMDCR/AA
AM048NXMDCR/AA
COND. WEIGHT (LBS)
143
143
143
81
154
214
214
214
214
214
214
COND. ELEC
(MCA)
16.9
16.9
16.9
10.3
23.0
29.0
29.0
29.0
29.0
29.0
29.0
(V/PH/HZ)
1/208/60
1/208/60
1/208/60
1/208/60
1/208/60
1/208/60
1/208/60
1/208/60
1/208/60
1/208/60
1/208/60
O/A TEMP. (DEG. F)
SUMMER DB
95
95
95
95
95
95
95
95
95
95
95
RM SETPOINT
DEG F
74
74
74
74
74
74
74
74
74
74
74
NOTES
ALL
ALL
ALL
1,2,3,4,5,7,8
ALL
1,2,3,4,6,7,8
1,2,3,4,6,7,8
1,2,3,4,6,7,8
1,2,3,4,6,7,8
1,2,3,4,6,7,8
1,2,3,4,6,7,8
OWNER SUPPLIED EQUIPMENT - ASSIGNED TO THE PROJECT
AIR HANDLING UNIT
TAG
NOTES:
NOTES:
1
2
3
HV-1
ALL
PROVIDE ROOF CURB ADAPTOR KIT TO UTILIZE EXISTING ROOF CURB.
CONTRACTOR TO SEAL AND WEATHER PROOF AND UNUSED EXISTING
OPENING.
"NEW UNIT WEIGHT" + "ROOF CURB ADAPTOR WEIGHT" SHALL NOT EXCEED
THE WEIGHT OF THE EXISITNG UNIT.
CONTRACTOR TO RETAIN STRUCTURAL CONSULTANT REGISTERED IN
BRITISH COLUMBIA IF THE "NEW UNIT WEIGHT" + "ROOF CURB ADAPTOR WEIGHT
" EXCEEDS THE EXISITNG UNIT WEIGHT.
HV-2
ALL
HV-3
ALL
CONTRACTOR SCOPE
OWNER SUPPLIED EQUIPMENT - ASSIGNED TO THE PROJECT
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
MECHANICALSCHEDULES
M0.02
AS NOTED
SCALE:
1
M0.03
1'-0" = 3/32"
HVAC ROOF PLAN
HV-1
HV-2
HV-3
2
M1.07
2
M1.06
TRUE NORTH
KEY PLAN
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
HVAC ROOF PLAN
M0.03
AS NOTED
SCALE:
1
M0.04
1'-0" = 3/32"
HVAC LEVEL 1 PLAN
1
M1.03
1
M1.05
CU-2
CU-1
1
M1.04
CU-3
1
M1.08
TRUE NORTH
KEY PLAN
HVAC LEVEL 1 PLAN
M0.04
AS NOTED
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
SCALE:
1
M0.05
1'-0" = 3/32"
HVAC BASEMENT PLAN
1
M1.02
1
M1.01
CU-5
CU-4
TRUE NORTH
KEY PLAN
M0.05
AS NOTED
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
HVAC BASEMENTPLAN
CU-4
T
38"x64" CONCRETE PAD
IMG
8087
IMG
2341
RF
GR
RF
GS
RF
GR
RF
GS
C
AC-9
AC-10
ALL REFRIGERANT, CONDENSATE,
POWER AND CONTROL LINES ARE
TO RUN INSIDE BULK HEAD TIGHT
TO CEILING/WALL
6' HIGH CHAIN-LINK FENCE WITH LOCKABLE GATE
DRAWING NOTES:
1. AC LINES TO RUN TIGHT TO CEILING WITHIN BULK HEAD IN
CORNER OF ROOM.
2. AC LINE ROUTING TO INCLUDE; REFRIGERANT, POWER,
CONDENSATE AND CONTROL LINES. LINE LOCATIONS ARE FOR
REFERENCE ONLY.
3. OUTDOOR PIPING TO BE SUPPORTED ON MI-FAB C5-B RUBBER
SUPPORTS.
4. CONDENSATE DRAIN LOCATION TO BE COORDINATED ON SITE.
5. INDOOR EVAPORATOR UNITS TO BE MOUNTED TIGHT TO
CEILING.
6. ALL LOW VOLTAGE CONTROL WIRING FOR AC UNITS AND HRV
TO BE DONE BY MECHANICAL. ALL WIRING TO BE RUN WITHIN
WIRE MOLD TO MATCH ELECTRICAL.
NEW PENETRATION TO BE COORDINATED ON SITE, TYP. OF 3
AC-11
DO ENABLE/ DISABLE
ALL 3 INDOOR UNIT ON
SINGLE ENABLE/DISABLE
AI TEMP
PAD MOUNTED ON 2@
DURA-BLOCK
ALL REFRIGERANT, CONDENSATE,
POWER AND CONTROL LINES ARE
TO FEED AC-10 AND AC-9 FROM
EXTERIOR. AC-9 AND AC-10 TO
FLUSH MOUNT TO WALL.
X X X X
AC UNITS TO BE MOUNTED ON
FACE OF BULKHEAD AND HAVE A
MINIMUM OF 4" CLEARANCE FROM
CEILING TO ALLOW FOR RETURN
AIR FLOW, TYP. OF 3
SCALE:
2
M0.01
NTS
IMAGE 8087
SCALE:
3
M0.01
NTS
IMAGE 2341
TRUE NORTH
KEY PLAN
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
HVACWILLOW ROOM
M1.01
1/4" = 1' - 0"
RENOVATION PLANSCALE:
1
M1.01
1'-0" = 1/4"
HVAC WILLOW ROOM RENOVATION PLAN
IMG
2531
SCALE:
2
M0.01
NTS
IMAGE 2531
CU-5
38x64" CONCRETE PAD
RF
GR
RF
GS
RF
GR
RF
GS
C
RFGR
RFGS
C
AC-7
AC-6
AC-8
ALL REFRIGERANT, CONDENSATE,
POWER AND CONTROL LINES ARE
TO RUN INSIDE BULK HEAD TIGHT
TO CEILING/WALL
T
X
4X
X
X X
DRAWING NOTES:
1. AC LINES TO RUN TIGHT TO CEILING WITHIN BULK HEAD IN
CORNER OF ROOM.
2. AC LINE ROUTING TO INCLUDE; REFRIGERANT, POWER,
CONDENSATE AND CONTROL LINES.LINE LOCATIONS ARE FOR
REFERENCE ONLY.
3. OUTDOOR PIPING TO BE SUPPORTED ON MI-FAB C5-B RUBBER
SUPPORTS.
4. CONDENSATE DRAIN LOCATION TO BE COORDINATED ON SITE.
5. INDOOR EVAPORATOR UNITS TO BE MOUNTED TIGHT TO
CEILING.
6. ALL LOW VOLTAGE CONTROL WIRING FOR AC UNITS AND HRV
TO BE DONE BY MECHANICAL. ALL WIRING TO BE RUN WITHIN
WIRE MOLD TO MATCH ELECTRICAL.
6' HIGH CHAIN-LINK FENCE
WITH LOCKABLE GATE
NEW PENETRATION TO BE COORDINATED ON SITE
NEW PENETRATION TO BE COORDINATED ON SITE
ENSURE EXISTING VENTILATOR REMAINS OPERATIONAL
AI TEMP
EXISTING BASEBOARD HEATER
DO ENABLE/ DISABLE
DO ENABLE/ DISABLE
DO ENABLE/ DISABLE
DO ENABLE/ DISABLE
AI TEMP
T
PAD MOUNTED ON 2@
DURA-BLOCK
AC UNITS TO BE MOUNTED ON
FACE OF BULKHEAD AND HAVE A
MINIMUM OF 4" CLEARANCE FROM
CEILING TO ALLOW FOR RETURN
AIR FLOW, TYP. OF 3
TRUE NORTH
KEY PLAN
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
HVACMAPLE ROOM
M1.02
1/4" = 1' - 0"
RENOVATION PLANSCALE:
1
M1.02
1'-0" = 1/4"
HVAC MAPLE ROOM RENOVATION PLAN
AC-4
DRAWING NOTES:
1. AC LINE ROUTING TO INCLUDE; REFRIGERANT, POWER,
CONDENSATE AND CONTROL LINES.
2. AC LINES TO RUN TIGHT TO CEILING WITHIN BULK HEAD IN
CORNER OF ROOM. LINE LOCATIONS ARE FOR REFERENCE
ONLY.
3. CONDENSATE DRAIN LOCATION TO BE COORDINATED ON SITE.
4. FINAL REVISION OF THE WALL MOUNT CONDENSER BRACKET
SHOP DRAWINGS SHALL BE COMPLETED WITH
MANUFACTURER'S BC REGISTERED ENGINEER'S SIGNED AND
SEALED SCHEDULE (FOR STRUCTURAL AND SEISMIC
DISCIPLINES)
5. INDOOR EVAPORATOR UNITS TO BE MOUNTED TIGHT TO
CEILING
6. ALL LOW VOLTAGE CONTROL WIRING FOR AC UNITS AND HRV
TO BE DONE BY MECHANICAL. ALL WIRING TO BE RUN WITHIN
WIRE MOLD TO MATCH ELECTRICAL.
7. PROVIDE FIRE DAMPER ACCESS PANEL AS REQUIRED. ACCESS
TO BE FROM ELECTRICAL ROOM
CU-1
C
RF
GR
RF
GS
WALL MOUNTED
CONDENSING UNIT, C/W
VIBRATION ISOLATION.
ALL REFRIGERANT,
CONDENSATE,
POWER AND
CONTROL LINES ARE
TO RUN INSIDE BULK
HEAD TIGHT TO
CEILING/WALL.
T
IMG
1748
SCALE:
2
M1.03
NTS
IMAGE 1748
T
R
FD
EF-1
FD
BDD
6"x6"
L-1
12"x12"
-
6"Ø
S-1
6"x6"
-
2@
1 TON
DO ENABLE/ DISABLE
AI TEMP
CONTRACTOR TO
FIRESTOP ALL
PENETRATIONS THROUGH
FIRE RATED WALLS
AC UNIT TO BE MOUNTED ON FACE
OF BULKHEAD AND HAVE A
MINIMUM OF 4" CLEARANCE FROM
CEILING TO ALLOW FOR RETURN
AIR FLOW
TRUE NORTH
KEY PLAN
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
HVACKITCHEN AREA
M1.03
1/4" = 1' - 0"
RENOVATION PLANSCALE:
1
M1.03
1'-0" = 1/4"
HVAC KITCHEN AREA RENOVATION PLAN
CU-3
IMG
8085
14
"x1
2"
14"x12"
T
C
1%
S
LO
PE
R-1
14"x14"
440
2@
S-1
8"x8"
220
4@
L-1
24"x12"
400
14"x12"
10
"Ø
8"Ø
8"Ø
12
"Ø
IMG
8086
IMG
8082
IMG
8083
IMG
8084
60"x62" CONCRETE PAD
RF
GS
RF
GR
DRAIN AC-7
CONDENSATE TO
SINK UPSTREAM
OF P-TRAP, REFER
TO DETAIL
1
M2.01
COORDINATE
FINAL LOCATION
ON SITE
10"Ø
ALL OUTDOOR
REFRIGERANT,
POWER AND
CONTROL LINES
ARE TO RUN
INSIDE FURRED
OUT PORTION OF
EXTERIOR WALL;
INSIDE LINES ARE
TO RUN WITHIN
CEILING PLENUM
8"Ø
8"Ø
12
"Ø
AC-5
36"X8.5" SUPPLY
36"x8.5" INTAKE
2-1/2 TON
DRAWING NOTES:
1. OUTDOOR PIPING TO BE SUPPORTED ON MI-FAB C5-B RUBBER
SUPPORTS.
2. ALL LOW VOLTAGE CONTROL WIRING FOR AC UNITS AND HRV
TO BE DONE BY MECHANICAL. ALL WIRING TO BE RUN WITHIN
WIRE MOLD TO MATCH ELECTRICAL.
AI TEMP
DO ENABLE/ DISABLE
TYP. OF 3
DO ENABLE/ DISABLE
EXISITNG
BASEBOARD HEATER
TYP. OF 3
PAD MOUNTED ON 2@
DURA-BLOCK
2% SLOPE
SCALE:
-
M1.04
NTS
IMAGE 8086
SCALE:
-
M1.04
NTS
IMAGE 8085
SCALE:
-
M1.04
NTS
IMAGE 8084
SCALE:
-
M1.04
NTS
IMAGE 8083
SCALE:
-
M1.04
NTS
IMAGE 8082
TRUE NORTH
KEY PLAN
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
HVACSPRUCE ROOM
M1.04
1/4" = 1' - 0"
RENOVATION PLANSCALE:
1
M1.04
1'-0" = 1/4"
HVAC SPRUCE ROOM RENOVATION PLAN
T
S
T
T
HRV-1 (A)
AC-1
HRV-2 (A)
AC-2
AC-3
HRV-3 (A)
FF-1
HRV-2 (B)
HRV-1 (B)
HRV-3 (B)
TO HRV-2 (B)
TO HRV-2 (A)
S
TO HRV-1 (B)
TO HRV-1 (A)
S
TO HRV-3 (B)
TO HRV-3 (A)
CU-2
DRAWING NOTES:
1. AC LINE ROUTING TO INCLUDE; REFRIGERANT, POWER,
CONDENSATE AND CONTROL LINES.
2. AC LINES TO RUN TIGHT TO WALL/CEILING WITHIN BULK HEAD IN
CORNER OF ROOM. LINE LOCATIONS ARE FOR REFERENCE
ONLY.
3. OUTDOOR PIPING TO BE SUPPORTED ON MI-FAB C5-B RUBBER
SUPPORTS.
4. CONDENSATE DRAIN LOCATION TO BE COORDINATED ON SITE.
5. INDOOR EVAPORATOR UNITS TO BE MOUNTED TIGHT TO
CEILING
6. ALL LOW VOLTAGE CONTROL WIRING FOR AC UNITS AND HRV
TO BE DONE BY MECHANICAL. ALL WIRING TO BE RUN WITHIN
WIRE MOLD TO MATCH ELECTRICAL.
CEILING
MOUNTED
SLAB TO MATCH WIDTH
OF CHIMNEY
PROTRUSION AND
EXTEND OUT TO BE
FLUSH WITH SIDEALK
PAD MOUNTED ON 2@
DURA-BLOCK
HRV TO BE CONNECTED TO
12VDC TRANSFORMER IN
WALL, ALL LOW VOLTAGE
CONTROL WIRING FOR HRV
TO BE DONE BY MECHANICAL.
TYPICAL OF 3.
HRV TO BE FLUSH ON
INTERIOR FINISHED WALL
AND PROTRUDE OUT
THROUGH ENVELOPE. REFER
TO DETAIL BY ARCHITECT
FOR PENETRATION DETAILS
AND LOCATION. TYP. OF 3
AC
LIN
E R
OU
TIN
G
AI TEMP
DO ENABLE/ DISABLE
DO ENABLE/ DISABLE
TYP. OF 3
TYP. OF 3
TYP. OF 3
EXISTING BASEBOARD
TYP. OF 3
AC UNITS TO BE MOUNTED ON
FACE OF BULKHEAD OR WALL AND
HAVE A MINIMUM OF 4"
CLEARANCE FROM CEILING TO
ALLOW FOR RETURN AIR FLOW,
TYP. OF 3
TRUE NORTH
KEY PLAN
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
HVACOFFICE AREA
M1.05
1/4" = 1' - 0"
RENOVATION PLANSCALE:
1
M1.05
1'-0" = 1/4"
HVAC OFFICE AREA RENOVATION PLAN
DRAWING NOTES:
PROVIDE ROOF CURB ADAPTOR KIT TO UTILIZE EXISTING
ROOF CURB. CONTRACTOR TO SEAL AND WEATHER
PROOF AND UNUSED EXISTING OPENING.
1
1. PROVIDE PRIME COATED (FOR RUST PROTECTION) NEW STEEL
SUPPORT (2" HIGH) TO MATCH EXISTING ROOF CURB
DIMENSIONS, STEEL FRAME C/W NEOPRENE GASKETS ON TOP
AND BOTTOM, TO SIT ON EXISTING ROOF CURB BETWEEN
EXISTING ROOF CURB AND NEW ROOF CURB ADAPTOR. ALLOW
REQUIRED OPENINGS ON STEEL SUPPORT FRAME FOR
ANCHORING OF THE NEW UNIT. FINAL REVISION OF THE CURB
ADAPTOR SHOP DRAWINGS SHALL BE COMPLETED WITH
MANUFACTURER'S BC REGISTERED ENGINEER'S SIGNED AND
SEALED SCHEDULE (FOR STRUCTURAL AND SEISMIC
DISCIPLINES)
2. ACOUSTICAL INSULATIONS REPLACEMENT WITHIN THE EXISTING
ROOF CURBS, REINFORCING THE EXISTING ROOF CURBS.
3. PROVIDE FLEXIBLE COUPLING BETWEEN RTU AND NEW
DUCTWORK.
4. CONTRACTOR TO ALLOW FOR REPLACEMENT OF GAS LINE AND
REGULATOR TO SUIT HV-3 REPLACEMENT.
5. FINAL FINISH OF ROOF CURB TO BE WEATHER RESISTANT AND
INSULATED.
6. CONTRACTOR TO ALLOW FOR SHEET METAL TRANSITIONS
BETWEEN HV-3 AND EXISTING DUCTWORK.
7. OUTDOOR PIPING TO BE SUPPORTED ON MI-FAB C5-B RUBBER
SUPPORTS
8. PROVIDE NEW INDOOR THERMOSTAT IN EXISTING LOCATION.
HV-1
DEMO EXISTING RTU
EXISTING RTU ROOF
CURB TO REMAIN
HV-3
EXISTING RTU ROOF
CURB
1
TRUE NORTH
KEY PLAN
TRUE NORTH
KEY PLAN
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
HVACROOF NORTH
M1.06
1/4 = 1' - 0"
RENOVATION PLANSCALE:
1
M1.06
1'-0" = 1/4"
HVAC ROOF NORTH DEMOLITION PLAN
SCALE:
2
M1.06
1'-0" = 1/4"
HVAC ROOF NORTH RENOVATION PLAN
HV-1
HV-2
31"X42" RA UP
16"x22" SA
21"X14" SA DOWN
30"X22" RA
46"X22" SA
DEMO EXISTING RTU
EXISTING RTU ROOF
CURB TO REMAIN
DEMO EXISTING RTU
EXISTING RTU ROOF
CURB TO REMAIN
HV-1
HV-2
31"X42" RA UP
16"x22" SA
21"X14" SA DOWN
30"X22" RA
46"X22" SA
EXISTING RTU ROOF
CURB
1
20"x23"
50"x23"
50"x24"
RA
EXISTING RTU ROOF
CURB
1
6' MIN DISTANCE
5' MIN DISTANCE
SA
RA
27"x47"
28"x47"
46"x22"
27"x30"
20"x23"
17"x32"
42"x12"
42"x32"
SA
DRAWING NOTES:
PROVIDE ROOF CURB ADAPTOR KIT TO UTILIZE EXISTING
ROOF CURB. CONTRACTOR TO SEAL AND WEATHER
PROOF AND UNUSED EXISTING OPENING.
1
1. PROVIDE PRIME COATED (FOR RUST PROTECTION) NEW STEEL
SUPPORT (2" HIGH) TO MATCH EXISTING ROOF CURB
DIMENSIONS, STEEL FRAME C/W NEOPRENE GASKETS ON TOP
AND BOTTOM, TO SIT ON EXISTING ROOF CURB BETWEEN
EXISTING ROOF CURB AND NEW ROOF CURB ADAPTOR. ALLOW
REQUIRED OPENINGS ON STEEL SUPPORT FRAME FOR
ANCHORING OF THE NEW UNIT. FINAL REVISION OF THE CURB
ADAPTOR SHOP DRAWINGS SHALL BE COMPLETED WITH
MANUFACTURER'S BC REGISTERED ENGINEER'S SIGNED AND
SEALED SCHEDULE (FOR STRUCTURAL AND SEISMIC
DISCIPLINES)
2. PROVIDE FLEXIBLE COUPLING BETWEEN RTU AND NEW
DUCTWORK.
3. CONTRACTOR TO ALLOW FOR REPLACEMENT OF GAS LINE AND
REGULATOR TO SUIT HV-1 & HV-2 REPLACEMENT.
4. FINAL FINISH OF ROOF CURB TO BE WEATHER RESISTANT AND
ACOUSTICALLY INSULATED.
5. PROVIDE ADEQUATE ROOF SUPPORTS FOR NEW DUCT WORK
COMPLETE WITH VIBRATION ISOLATION.CONTRACTOR TO
ALLOW FOR WIND UPLIFT EFFECT ON EXPOSED DUCT WORK.
6. CONTRACTOR TO ALLOW FOR RE-INSULATION OF EXISTING
OUTDOOR DUCTWORK.
8. PROVIDE NEW INDOOR THERMOSTAT IN EXISTING LOCATION.
TRUE NORTH
KEY PLAN
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
HVACROOF SOUTH
M1.07
1/4 = 1' - 0"
RENOVATION PLANSCALE:
1
M1.07
1'-0" = 1/4"
HVAC ROOF SOUTH DEMOLITION PLAN
SCALE:
2
M1.07
1'-0" = 1/4"
HVAC ROOF SOUTH RENOVATION PLAN
DO ENABLE/ DISABLE
DO ENABLE/ DISABLE
DO ENABLE/ DISABLE
EXISTING BASEBOARD HEATER
TYP. OF 3
EXISTING WINDOW MOUNTED
AC UNIT TO BE DEMOLISHED
TYP. OF 2
TRUE NORTH
KEY PLAN
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
HVAC CEDAR,ARBUTUS & BIRCH
M1.08
1/4" = 1' - 0"
RENOVATION PLANSCALE:
1
M1.08
1'-0" = 1/4"
HVAC CEDAR, ARBUTUS & BIRCH RENOVATION PLAN
DHWDCW
SCALE:
1
M2.01
NTS
CONDENSATE TIE-IN
V
VENT
FLOOR
LEVEL
C
TIE CONDENSATE DRAIN
INTO SINK SAN LINE
UPSTREAM OF P-TRAP
FROM CONDENSATE PUMP(S)
RE & RE DRYWALL TO MATCH
EXISITING
NOTE:
* SIESMIC RESTRAINTS AS PER
SPECIFICATIONS
INSULATED
SOLID DUCT
INSULATED
FLEX DUCT
CEILING
900 (36") (MAX.
STRETCHED)
S/A DIFFUSER
ATTACH DIFFUSER
TO DUCT TEE
END CAP
INSULATED DUCT TEE
(AIR CUSHION)
ATTACH TO STRUCTURE
AIR OUTLET/INLET SEE
SCHEDULE & DWG's FOR TYPE
TYPE A FIRE DAMPER
FUSIBLE LINK
FIRE RATED WALL
DUCT
ANGLE FRAME
TIE CLIPS
DETAIL NOTES
1. INSTALL IN ACCORDANCE WITH
MANUFACTURER
SPECIFICATIONS & SMACNA
RECOMMENDATIONS
BREAK AWAY
JOINT
SERVICE VALVES
INSULATION
MINI SPLIT HEAT PUMP OR AC
SYSTEM, AS SPEC'D, TO BE
INSTALLED ACCORDING TO ALL
APPLICABLE NATIONAL AND
LOCAL ELECTRICAL,
MECHANICAL AND BUILDING
CODES
WEATHERPROOF
FUSED DISCONNECT
PER NEC
INSTALL OUTDOOR UNIT PER
MANUFACTURER SPECIFICATIONS
WALL MOUNTED INDOOR UNIT
PER MANUFACTURER
SPECIFICATIONS
WALL HOLE SLEEVE
REFER TO MANUFACTURER FOR
MINIMUM INSTALLATION
CLEARANCES
REFRIGERANT LINE FLARED
CONNECTION
DRAIN LINE (INSULATE IN
UNCONDITIONED SPACE)
POWER AND CONTROL
WIRING (HIGH
VOLTAGE)
OUTDOOR UNIT TO BE
SUPPORTED FROM WALL ON
STEEL ANGLE FRAME c/w
SEISMIC RESTRAINT.
SCALE:
2
M2.01
NTS
SUPPLY AIR DIFFUSER
SCALE:
3
M2.01
NTS
DUCTLESS SPLIT SYSTEM DETAIL
SCALE:
4
M2.01
NTS
VERTICAL FIRE DAMPER DETAIL
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
MECHANICALDETAILS
M2.01
N.T.S.
COMMON WORKS
1. GENERAL
1.1 GENERAL SCOPE
'PROVIDE' SHALL MEAN SUPPLY AND INSTALL.
'CONSULTANT' SHALL MEAN AME GROUP CONSULTING PROFESSIONAL ENGINEERS
PROVIDE COMPLETE, FULLY TESTED AND OPERATIONAL SYSTEMS TO MEET THE REQUIREMENTS DESCRIBED
HEREIN AND IN COMPLETE ACCORD WITH APPLICABLE CODES AND ORDINANCES.
CONTRACT DOCUMENTS AND DRAWINGS ARE DIAGRAMMATIC. THEY ESTABLISH SCOPE, MATERIAL AND
INSTALLATION QUALITY BUT ARE NOT DETAILED INSTALLATION INSTRUCTIONS.
FOLLOW MANUFACTURERS' RECOMMENDED INSTALLATION INSTRUCTIONS, DETAILS AND PROCEDURES FOR
EQUIPMENT, SUPPLEMENTED BY REQUIREMENTS OF THE CONTRACT DOCUMENTS.
BEFORE SUBMITTING TENDER, VISIT AND EXAMINE THE SITE AND NOTE ALL CHARACTERISTICS AND FEATURES
AFFECTING THE WORK. NO ALLOWANCES WILL BE MADE FOR ANY DIFFICULTIES ENCOUNTERED OR ANY
EXPENSES INCURRED BECAUSE OF ANY CONDITIONS OF THE SITE OR ITEM EXISTING THEREON, WHICH IS
VISIBLE OR KNOWN TO EXIST AT THE TIME OF TENDER.
CLARIFICATIONS OR REQUESTS FOR ALTERNATE MATERIALS OR EQUIPMENT MUST BE SUBMITTED IN WRITING
TO THE CONSULTANT NO LATER THAN SEVEN (7) WORKING DAYS PRIOR TO THE MECHANICAL TRADES'
CLOSING TENDER DATE. APPROVAL OF REQUESTS SHALL ONLY BE GIVEN BY ADDENDUM.
MAKE REFERENCE TO ELECTRICAL, MECHANICAL, STRUCTURAL AND ARCHITECTURAL DRAWINGS WHEN
SETTING OUT WORK. CONSULT WITH RESPECTIVE DIVISIONS IN SETTING OUT LOCATIONS FOR DUCTWORK,
EQUIPMENT, AND PIPING, SO THAT CONFLICTS ARE AVOIDED AND SYMMETRICAL EVEN SPACING IS
MAINTAINED. JOINTLY WORK OUT ALL CONFLICTS ON SITE BEFORE FABRICATING OR INSTALLING ANY
MATERIALS OR EQUIPMENT.
1.2 CODE COMPLIANCE, PERMITS AND FEES
ALL WORK SHALL COMPLY WITH CURRENT EDITIONS OF THE NATIONAL, PROVINCIAL AND MUNICIPAL CODES,
STANDARDS, ACTS AND BYLAWS AND WILL MEET THE REQUIREMENTS OF THE AUTHORITY HAVING
JURISDICTION.
OBTAIN ALL PERMITS AND PAY ALL FEES APPLICABLE TO THE SCOPE OF WORK. CONTRACTOR SHALL
ARRANGE FOR INSPECTIONS OF THE WORK BY THE AUTHORITIES HAVING JURISDICTION AND SHALL PROVIDE
CERTIFICATES INDICATING FINAL APPROVAL.
1.3 TENDER PRICE BREAKDOWN
SUBMIT A TENDER PRICE BREAKDOWN WITHIN THIRTY (30) DAYS OF TENDER CLOSING AND BEFORE FIRST
PROGRESS CLAIM, IN A FORMAT AGREED TO WITH THE CONSULTANT. AS A MINIMUM INCLUDE EQUIPMENT,
MATERIALS AND LABOUR FOR MECHANICAL, PLUMBING, SHEET METAL, FIRE PROTECTION AND CONTROLS.
1.4 SUBMITTALS
COMPLY WITH DIVISION 1 - SUBMISSION AND CLOSEOUT PROCEDURES AND IN ADDITION THE FOLLOWING:
CONTRACTOR SHALL PROVIDE AND SUBMIT TO THE CONSULTANT ASSURANCE OF PROFESSIONAL DESIGN
AND COMMITMENT FOR FIELD REVIEW SCHEDULE B AND ASSURANCE OF PROFESSIONAL FIELD REVIEW AND
COMPLIANCE SCHEDULE C-B FOR SEISMIC ENGINEERING.
SHOP DRAWINGS: PROVIDE SHOP DRAWINGS FOR ALL EQUIPMENT AS ELECTRONIC FILES (FILE FORMAT: .DWG,
.DXF, PDF, OR COMPARABLE). WHEN MANUFACTURER'S CUT SHEETS APPLY TO A PRODUCT SERIES RATHER
THAN A SPECIFIC PRODUCT, THE DATA SPECIFICALLY APPLICABLE TO THE PROJECT SHALL BE HIGHLIGHTED
OR CLEARLY INDICATED BY OTHER MEANS. EACH SUBMITTED PIECE OF LITERATURE AND DRAWINGS SHALL
CLEARLY REFERENCE THE SPECIFICATION AND/OR DRAWING THAT THE SUBMITTAL IS TO COVER. GENERAL
CATALOGS SHALL NOT BE ACCEPTED AS CUT SHEETS TO FULFILL SUBMITTAL REQUIREMENTS.
CLOSEOUT SUBMITTALS: PROVIDE A MINIMUM OF TWO (2) MECHANICAL OPERATION AND MAINTENANCE
MANUALS AND ONE DIGITAL COPY, PREPARED BY THE TAB CONTRACTOR.
OPERATION AND MAINTENANCE MANUAL APPROVED BY, AND FINAL COPIES DEPOSITED WITH THE
CONSULTANT A MINIMUM OF 7-DAYS BEFORE FINAL INSPECTION.
OPERATION AND MAINTENANCE MANUAL TO INCLUDE BUT NOT LIMITED TO: LAYMAN'S DESCRIPTION OF THE
SYSTEMS AND ASSOCIATED CONTROLS; OPERATIONAL INSTRUCTIONS, SERVICING, MAINTENANCE,
OPERATION AND TROUBLE-SHOOTING INSTRUCTIONS FOR EACH ITEM OF EQUIPMENT; WARRANTIES;
EQUIPMENT MANUFACTURER'S PERFORMANCE DATASHEETS INDICATING POINT OF OPERATION AS LEFT
AFTER COMMISSIONING IS COMPLETE; TESTING, ADJUSTING AND BALANCING REPORTS.
RECORD DRAWINGS: CONSULTANT WILL PROVIDE 1 SET OF WHITE PRINTS AT CONTRACTORS COST TO MARK
CHANGES AS WORK PROGRESSES AND AS CHANGES OCCUR. USE DIFFERENT COLOUR WATERPROOF INK FOR
EACH SERVICE. DO NOT USE PENCIL OR BLACK INK. TRANSFER INFORMATION WEEKLY TO SHOW WORK AS
ACTUALLY INSTALLED. DRAWINGS SHALL BE AVAILABLE ON A WEEKLY BASIS FOR REVIEW BY THE
CONSULTANT.
IDENTIFY EACH DRAWING IN LOWER RIGHT HAND CORNER IN LETTERS AT LEAST 12 MM HIGH AS FOLLOWS: -
"AS BUILT DRAWINGS: THIS DRAWING HAS BEEN REVISED TO SHOW MECHANICAL SYSTEMS AS INSTALLED"
(SIGNATURE OF CONTRACTOR) (DATE).
SUBMIT TO CONSULTANT FOR APPROVAL AND MAKE CORRECTIONS AS DIRECTED.
SUBMIT COMPLETED CAD RECORD DRAWINGS WITH FINAL OPERATING AND MAINTENANCE MANUALS WITHIN
TWO (2) WEEKS OF SUBSTANTIAL COMPLETION. FAILURE TO SUBMIT DRAWINGS WILL RESULT IN THE WORK
BEING UNDERTAKEN BY THE OWNER AND DEDUCTED FROM THE CONTRACTOR'S HOLD BACK AMOUNT. COST
TO TRANSFER RECORD INFORMATION ONTO REPRODUCIBLE MEDIA & AUTO-CAD DISKS ARE THIS
CONTRACTOR'S RESPONSIBILITY. CONSULTANT WILL RELEASE DRAWINGS TO CONTRACTOR AFTER SIGNING
A COPYRIGHT FORM. SHOULD THE CONTRACTOR CHOOSE TO UTILISE THIS CONSULTANT FOR TRANSFERRING
AS BUILT INFORMATION, ALLOW $400 / SHEET FOR ALL DRAWINGS IN THE CONSTRUCTION SET. THIS WILL
COVER COSTS FOR DRAFTING TIME & PRINTING COSTS.
1.5 QUALITY OF WORK
ALL WORK SHALL BE BY QUALIFIED TRADESMEN WITH VALID PROVINCIAL TRADE QUALIFICATION
CERTIFICATES. SPOT CHECKS WILL BE MADE BY THE CONSULTANT. WORK WHICH DOES NOT CONFORM TO
STANDARDS MAY BE REJECTED BY THE CONSULTANT. THE CONTRACTOR SHALL REDO REJECTED WORK TO
THE ACCEPTED STANDARD AT NO COST TO THE OWNER.
1.6 DRAWINGS AND SPECIFICATIONS
SHOULD ANY DISCREPANCY APPEAR BETWEEN DRAWINGS AND SPECIFICATIONS OBTAIN WRITTEN
CLARIFICATION FROM THE CONSULTANT DURING THE TENDER PERIOD. WITHOUT A WRITTEN CLARIFICATION
THE BETTER QUALITY AND/OR GREATER QUANTITY OF WORK OR MATERIALS SHALL BE ESTIMATED,
PERFORMED AND FURNISHED WITHIN THE TENDERED PRICE.
1.7 CUTTING, PATCHING AND CORING
PROVIDE HOLES AND SLEEVES, CUTTING AND FITTING REQUIRED FOR MECHANICAL WORK. RELOCATE
IMPROPERLY LOCATED HOLES AND SLEEVES. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES.
OBTAIN WRITTEN APPROVAL FROM THE STRUCTURAL CONSULTANT BEFORE CUTTING OR BURNING
STRUCTURAL MEMBERS.
1.8 CONNECTIONS TO EXISTING SERVICES
MAINTAIN LIAISON WITH THE OWNER AND PROVIDE A MUTUALLY ACCEPTABLE SCHEDULE TO INTERRUPT,
REROUTE, OR CONNECT TO EXISTING BUILDING SERVICES WITH THE MINIMUM OF INTERRUPTION OF THOSE
SERVICES.
1.9 SELECTIVE DEMOLITION
REMOVE FROM SITE ALL EQUIPMENT, DUCTING OR PIPING WHICH IS NO LONGER REQUIRED BECAUSE OF
WORK UNDER THIS CONTRACT. EXCEPT AS OTHERWISE STATED, SALVAGEABLE MATERIALS FROM AREA OF
DEMOLITION SHALL BECOME THE PROPERTY OF THE OWNER AT HIS DISCRETION.
THE INTENT IS FOR A HAZ-MAT CONTRACTOR TO REMOVE ALL ASBESTOS CONTAINING MATERIAL PRIOR TO
THE PROPOSED PROJECT WORK TAKING PLACE. NOTIFY THE CONSULTANT IF ASBESTOS CONTAINING
MATERIAL IS SUSPECTED TO REMAIN ON SITE.
1.10 EQUIPMENT AND MATERIALS
WHERE TWO OR MORE PRODUCTS OF THE SAME TYPE ARE REQUIRED, PRODUCTS SHALL BE OF THE SAME
MANUFACTURER.
NOTIFY THE CONSULTANT IN WRITING TEN (10) DAYS PRIOR TO THE TENDER CLOSE, ANY MATERIALS OR
EQUIPMENT SPECIFIED WHICH IS NOT CURRENTLY AVAILABLE OR WILL NOT BE AVAILABLE FOR USE AS CALLED
FOR HEREIN. FAILING THIS, THE CONTRACT WILL ASSUME THAT THE MOST EXPENSIVE ALTERNATE HAS BEEN
INCLUDED IN THE TENDER PRICE.
ALL EQUIPMENT INSTALLED ON THIS PROJECT SHALL COMPLY WITH THE NATIONAL ENERGY CODE OF CANADA
FOR BUILDINGS - 2011, ASHRAE STANDARD 90.1 - 2010
1.11 DELIVERY, STORAGE AND HANDLING
STORE MATERIALS AND EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS IN A
CLEAN, DRY, WELL-VENTILATED AREA.
REPLACE DEFECTIVE OR DAMAGED MATERIALS WITH NEW.
1.12 FIRESTOPPING AND SMOKE SEALS
PROVIDE FIRESTOPPING SYSTEM(S) TO PROVIDE AND MAINTAIN A FIRE RESISTANCE RATING, AS INDICATED ON
DRAWINGS AND IN ACCORDANCE WITH UL, WH, ULC, CUL OR FM DESIGN DETAILS FOR ALL MECHANICAL WORK
IN DIVISIONS 21, 22, 23 AND 25
FOR RENOVATION PROJECTS, IN ADDITION TO THE NECESSARY NEW PENETRATIONS, PROVIDE THE
FIRESTOPPING FOR ALL EXISTING MECHANICAL ASSEMBLIES WHERE FIRESTOPPING IS DAMAGED,
DISCONTINUED OR ABSENT WITHIN THE CONSTRUCTION AREA.
ALL FIRESTOP SYSTEM INSTALLATIONS MUST MEET THE REQUIREMENTS OF CAN4-S115-M OR ULC S-115-M
TESTED ASSEMBLIES THAT PROVIDE A FIRE RATING
1.13 ACCESS DOORS
PROVIDE ACCESS DOORS FOR MAINTENANCE OR ADJUSTMENT OF ALL PARTS OF THE MECHANICAL SYSTEM.
PROVIDE 300 MM X 300 MM MINIMUM SIZE FOR INSPECTION AND HAND ACCESS.
600 MM X 600 MM MINIMUM SIZE, LARGER IF INDICATED ON DRAWINGS, WHERE ENTRY IS REQUIRED AND
ACCESS IS DIFFICULT.
1.14 ESCUTCHEONS AND PLATES
PROVIDE ESCUTCHEONS AND PLATES ON ALL PIPING AND DUCTWORK PASSING THROUGH FINISHED WALLS,
FLOORS, AND CEILINGS.
1.15 GUARANTEE / WARRANTY
FURNISH A WRITTEN GUARANTEE STATING THAT ALL WORK EXECUTED IN THIS CONTRACT WILL BE FREE FROM
DEFECTIVE WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF SUBSTANTIAL
PERFORMANCE.
1.16 BALANCING
THE APPROVED BALANCING AGENCIES ARE: WESTERN MECHANICAL; K.D. ENGINEERING, FLOTECH
MECHANICAL, BLUE COLLAR GROUP.
BALANCE TERMINAL BOXES, EXHAUST FANS AND AIR OUTLETS TO AIR QUANTITIES INDICATED ON THE
DRAWINGS AND IN THIS SPECIFICATION. WHERE OUTLET QUANTITIES ARE NOT INDICATED, DIVIDE BOX
CAPACITY EQUALLY AMONG ALL OUTLETS.
SUBMIT TWO (2) COPIES OF THE REPORT TO THE CONSULTANT WITHIN TWO (2) WEEKS AFTER SUBSTANTIAL
COMPLETION. FAILURE TO SUBMIT THE REPORT WITHIN THE SPECIFIED TIME WILL RESULT IN THE WORK
BEING DONE BY THE OWNER AND THE COSTS DEDUCTED FROM FINAL PAYMENT.
BALANCING SHALL BE PERFORMED TO THE FOLLOWING:
AIR-TERMINAL OUTLETS ±10%
AIR-CENTRAL EQUIPMENT ± 5%
CENTRAL EQUIPMENT ± 5%
PROVIDE A DROP TEST OF ALL FIRE DAMPERS AND A LETTER/CERTIFICATE CONFIRMING THIS WORK.
COOPERATE WITH THE BALANCING AGENCY AND MAKE ANY CORRECTIONS AS REQUIRED BY BALANCING
AGENCY.
PROVIDE BALANCING VALVES AND DAMPERS, PULLEYS, SHEAVES ETC. AS REQUESTED BY THE BALANCING
AGENCY AND/OR NECESSARY TO PROPERLY ADJUST OR CORRECT THE SYSTEMS TO DESIGN FLOWS,
WITHOUT ADDITIONAL COST TO OWNER.
1.17 FLASHING AND ROOF CURBS
PROVIDE CURBS, FLASH AND COUNTER FLASH AS REQUIRED WHERE MECHANICAL EQUIPMENT PASSES
THROUGH WEATHER OR WATERPROOFED WALLS, FLOORS AND ROOFS.
PROVIDE FACTORY ROOF CURBS FOR ALL ROOF MOUNTED EQUIPMENT UNLESS NOTED OTHERWISE.
1.18 SEISMIC CONTROL
PROVIDE SEISMIC RESTRAINTS FOR ALL REQUIRED EQUIPMENT, PIPING, AND DUCTWORK IN ACCORDANCE
WITH THE LATEST EDITION OF THE SEISMIC RESTRAINTS MANUAL FOR MECHANICAL SYSTEMS PRODUCED BY
SMACNA, AND THE LATEST EDITION OF THE ASHRAE APPLICATION HANDBOOK CHAPTER 49, SEISMIC
RESTRAINTS.
THE CONTRACTOR SHALL RETAIN THE SERVICES OF A QUALIFIED PROFESSIONAL SEISMIC ENGINEER (SEISMIC
ENGINEER) REGISTERED IN THE PROVINCE OF [ALBERTA] [BRITISH COLUMBIA]. THE SEISMIC ENGINEER SHALL
DESIGN AND REVIEW THE INSTALLATION OF ALL SEISMIC RESTRAINTS AS WELL AS MECHANICAL EQUIPMENT
AND MECHANICAL SYSTEM SUPPORTS. THE RESTRAINTS AND SUPPORTS SHALL BE SPECIFICALLY DESIGNED
TO FASTEN TO THE STRUCTURE INDICATED IN THE CONTRACT DOCUMENTS AND INSTALLED IN THE FIELD.
THE COMPLETE DESIGN FOR THESE SYSTEMS SHALL COMPLY WITH ALL APPLICABLE BUILDING CODE
REQUIREMENTS.
SEISMIC ENGINEER SHALL PROVIDE AND SUBMIT TO THE OWNER'S CONSULTANT ASSURANCE OF
PROFESSIONAL DESIGN AND COMMITMENT FOR FIELD REVIEW SCHEDULE B AND ASSURANCE OF
PROFESSIONAL FIELD REVIEW AND COMPLIANCE SCHEDULE C-B FOR SEISMIC ENGINEERING.
1.19 VIBRATION ISOLATION
PROVIDE NEOPRENE ISOLATORS FOR DEFLECTIONS 6MM (1/4”) AND UNDER.
PROVIDE EITHER NEOPRENE OR STEEL SPRING ISOLATORS FOR DEFLECTIONS BETWEEN 6MM AND 12MM (½”).
PROVIDE STEEL SPRING ISOLATORS FOR DEFLECTIONS OF 12MM (½”) AND OVER.
PROVIDE ADJUSTABLE LIMIT STOPS FOR SPRING ISOLATION MOUNTS ON EQUIPMENT WITH OPERATING
WEIGHTS SUBSTANTIALLY DIFFERENT FROM THE INSTALLED WEIGHTS
ALL SPRING ISOLATORS SHALL BE “OPEN SPRING” UNLESS OTHERWISE STATED. SEISMICALLY RATED HOUSED
SPRING ISOLATORS MAY BE USED IN LIEU PROVIDED THAT THEY MEET THIS PROJECT'S REQUIREMENTS FOR
SEISMIC RESTRAINT.
SELECT ISOLATORS IN ACCORDANCE WITH EQUIPMENT WEIGHT DISTRIBUTION TO ALLOW FOR AN AVERAGE
DEFLECTION MEETING OR EXCEEDING THE SPECIFIED DEFLECTION REQUIREMENTS AND SO THAT NO
ISOLATOR HAS A DEFLECTION LESS THAN 80% OF THE STATIC DEFLECTION SPECIFIED. A MINIMUM OF 4
ISOLATORS ARE REQUIRED FOR EACH PIECE OF EQUIPMENT, UNLESS SPECIFIED OTHERWISE.
1.20 SUBSTANTIAL AND TOTAL PERFORMANCE
PRIOR TO REQUESTING AN INSPECTION FOR SUBSTANTIAL PERFORMANCE, PROVIDE A COMPLETE LIST OF
ITEMS, WHICH ARE DEFICIENT.
A CERTIFICATE OF SUBSTANTIAL PERFORMANCE WILL NOT BE GRANTED UNLESS THE FOLLOWING ITEMS ARE
COMPLETED AND AVAILABLE TO THE OWNER'S CONSULTANT:
FINAL PLUMBING INSPECTION CERTIFICATE FROM THE AUTHORITY HAVING JURISDICTION.
FINAL GAS INSPECTION CERTIFICATE FROM THE AUTHORITY HAVING JURISDICTION.
SCHEDULE C-B FOR FIRE SUPPRESSION AND FIRE SPRINKLER MATERIALS AND TEST CERTIFICATE.
SCHEDULE C-B FOR SEISMIC ENGINEERING.
FIRE STOPPING AND FIRE DAMPER TEST LETTER
DRAFT OPERATING/MAINTENANCE MANUALS HAVE BEEN SUBMITTED FOR REVIEW.
ALL MECHANICAL SYSTEMS HAVE BEEN COMMISSIONED AND ARE CAPABLE OF OPERATION WITH ALARM
CONTROLS FUNCTIONAL AND AUTOMATIC CONTROLS IN OPERATION.
AIR SYSTEMS HAVE BEEN BALANCED WITH DRAFT REPORT SUBMITTED TO THE CONSULTANT.
OPERATING AND MAINTENANCE DEMONSTRATIONS HAVE BEEN PROVIDED TO THE OWNER.
RECORD DRAWINGS HAVE BEEN SUBMITTED.
ALL PREVIOUSLY IDENTIFIED DEFICIENCIES HAVE BEEN CORRECTED AND ACCEPTED.
PRIOR TO A TOTAL PERFORMANCE INSPECTION PROVIDE DECLARATION IN WRITING THAT SUBSTANTIAL
PERFORMANCE DEFICIENCIES HAVE BEEN CORRECTED AND FINAL TAB REPORTS AND O&M MANUALS HAVE
BEEN SUBMITTED.
THE CONSULTANT SHALL PROVIDE ONE (1) VISITATION FOR THE PURPOSE OF TOTAL PERFORMANCE
INSPECTION. SUBSEQUENT VISITATIONS IF REQUIRED SHALL BE AT THE EXPENSE OF THE CONTRACTOR.
1.21 MATERIALS AND EQUIPMENT
APPROVED EQUIVALENTS AND/OR ALTERNATIVES TO SPECIFIED PRODUCTS SHALL BE EQUAL TO THE
SPECIFIED PRODUCT IN EVERY RESPECT, OPERATE AS INTENDED, AND MEET THE SPACE, CAPACITY, AND
NOISE REQUIREMENTS OUTLINED. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ANY ADDITIONAL
LABOUR AND MATERIALS REQUIRED BY ANY TRADES OR OTHER CONTRACTORS TO ACCOMMODATE THE USE
OF OTHER THAN SPECIFIED MATERIALS OR EQUIPMENT. THE CONTRACTOR SHALL BEAR ANY AND ALL COSTS
FOR DESIGN/SYSTEM MODIFICATIONS TO ACCOMMODATE THE “ALTERNATE” EQUIPMENT. EXTRAS WILL NOT BE
APPROVED TO COVER SUCH WORK.
2. PRODUCTS
2.1 ACCEPTABLE MANUFACTURERS
LISTED MANUFACTURERS ARE ACCEPTABLE FOR THEIR ABILITY TO MEET THE GENERAL DESIGN INTENT,
QUALITY AND PERFORMANCE CHARACTERISTICS OF THE SPECIFIED PRODUCT. THE LIST DOES NOT ENDORSE
THE ACCEPTABILITY OF ALL PRODUCTS AVAILABLE FROM THE LISTED MANUFACTURERS/SUPPLIERS.
IT REMAINS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THE PRODUCTS SUPPLIED ARE EQUAL TO
THE SPECIFIED PRODUCTS IN EVERY RESPECT, OPERATE AS INTENDED, AND MEET THE PERFORMANCE
SPECIFICATIONS AND PHYSICAL DIMENSIONS OF THE SPECIFIED PRODUCT.
THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ANY ADDITIONAL WORK OR MATERIALS, TO
ACCOMMODATE THE USE OF EQUIPMENT FROM THE ACCEPTABLE MANUFACTURERS AND SUPPLIERS LISTED.
2.2 FIRESTOPPING AND SMOKE SEALS
USE THE SAME MANUFACTURER THROUGHOUT THE PROJECT AND COMPATIBLE MATERIALS FOR
RESTORATION WORK.
PROVIDE FILL MATERIAL COMPONENTS FOR EACH FIRESTOPPING SYSTEM AS NEEDED. USE ONLY
COMPONENTS SPECIFIED BY THE FIRESTOPPING MANUFACTURER FOR THE DESIGNATED
FIRE-RESISTANCE-RATED SYSTEMS.
ACCEPTABLE MANUFACTURERS: 3M, HILTI, AD FIREBARRIER, TREMCO
2.3 PIPE HANGERS AND SUPPORTS
PROVIDE HANGERS AND SUPPORTS TO SECURE EQUIPMENT IN PLACE, PREVENT VIBRATION, PROTECT
AGAINST DAMAGE FROM EARTHQUAKE, MAINTAIN GRADE, PROVIDE FOR EXPANSION AND CONTRACTION, AND
ACCOMMODATE INSULATION.
2.4 ACCESS DOORS
DRYWALL SURFACE: EXTRUDED ALUMINUM FRAME WITH GYPSUM BOARD INLAY AND STRUCTURAL CORNER
ELEMENTS. HINGE TO BE CONCEALED 2-POINT HINGE, NON-CORRODING WITH SCREWDRIVER OPERATED CAM
LATCH.
TILE SURFACE: UNIVERSAL DESIGN, STAINLESS STEEL DOOR (16GA) AND STAINLESS STEEL FRAME (18GA),
DOOR FLUSH TO FRAME, ROUNDED SAFETY CORNERS, CONTINUOUS CONCEALED HINGE, SCREWDRIVER
OPERATED CAM LATCH, #4 SATIN STAINLESS STEEL FINISH.
PLASTER WALLS AND CEILING: STEEL DOOR (14GA) AND STEEL FRAME (14GA), DOOR FLUSH TO FRAME EDGE,
EXPANSION CASING BEAD AND 75 MM WIDE GALVANIZED LATH SURROUND RECESSED 18 MM TO RECEIVE
PLASTER, CONTINUOUS CONCEALED HINGE, SCREWDRIVER OPERATED CAM LATCH, PRIME COAT GREY
PAINTED FINISH.
FIRE RATED WALLS NON-COMBUSTIBLE CONSTRUCTION: UNINSULATED STEEL DOOR (16GA) AND STEEL FRAME
(16GA), DOOR FLUSH TO FRAME EDGE, 25MM MOUNTING FRAME WITH MASONRY ANCHOR STRAPS,
CONCEALED SELF-CLOSING HINGE, FLUSH KEY LATCH, PRIME COAT GREY PAINTED FINISH, ULC RATED 2 HOUR
'B' LABEL.
FIRE RATED WALLS COMBUSTIBLE CONSTRUCTION: INSULATED STEEL DOOR (20GA) FOR MAXIMUM 250°C RISE
AFTER 30 MINUTES AND STEEL FRAME (16GA), DOOR FLUSH TO FRAME EDGE, 25MM MOUNTING FRAME WITH
MASONRY ANCHOR STRAPS, CONCEALED SELF-CLOSING HINGE, FLUSH KEY LATCH, PRIME COAT GREY
PAINTED FINISH, ULC RATED 1-1/2 HOUR 'B' LABEL.
FIRE RATED CEILINGS: 50MM INSULATED STEEL DOOR (16GA) AND STEEL FRAME (16GA), DOOR FLUSH TO
FRAME EDGE, 25MM MOUNTING FRAME WITH MASONRY ANCHOR STRAPS, CONCEALED UPSWING
SELF-CLOSING HINGE, L HANDLE LATCH, WHITE BAKED ENAMEL FINISH, SIZE 600MM X 600MM (24” X 24”) ULC
RATED 2 HOUR 'B' LABEL.
DUCTWORK: ULTRA LOW LEAKAGE TYPE, FLAT OVAL DESIGN, GALVANIZED STEEL FRAME (22GA), DOUBLE SKIN
GALVANIZED STEEL DOOR (22 GA) WITH 25MM INSULATION FULLY ENCLOSED IN PANEL, BULB TYPE SEAL
INTEGRALLY FASTENED TO DOOR, LEVER CAM LOCKS. PROVIDE STAINLESS STEEL IN LIEU OF GALVANIZED
STEEL IN STAINLESS STEEL DUCTWORK.
ACCEPTABLE MANUFACTURERS: MAXAM, ACUDOR, MILCOR, CAN.AQUA, MIFAB, BILCO, BAUCOPLUS
2.5 IDENTIFICATION
IDENTIFY PIPING WITH LABELS AND FLOW ARROWS. PROVIDE IDENTIFICATION AT 15M (50FT) MAXIMUM
INTERVALS, BEFORE AND AFTER PIPES PASSING THROUGH WALLS, AT ALL SIDES OF TEES, BEHIND ACCESS
DOORS. USE BRADY B-500 VINYL CLOTH LABELS FOR NON INSULATED PIPES AND B-350 FOR INSULATED PIPES.
PROVIDE 20MM (3/4”) DIAMETER BRASS TAGS, SECURE TO VALVE STEMS WITH KEY CHAIN. PROVIDE A VALVE
DIRECTORY AT ALL MECHANICAL ROOMS, IN THE O&M MANUALS AND A DIGITAL COPY CROSS REFERENCED
WITH ANY ASSOCIATED CONTROLS NOMENCLATURE.
EACH PIECE OF EQUIPMENT SHALL BE IDENTIFIED WITH ITS EQUIPMENT SCHEDULE IDENTIFICATION, E.G.
SUPPLY FAN SF-1, COOLING COIL CC-1, PUMP P-1 WITH LAMACOID PLATES HAVING 6MM (1/4”) MINIMUM LETTER
SIZE.
ACCEPTABLE MANUFACTURERS: BRADY
2.6 VIBRATION ISOLATION
NEOPRENE WASHER/BUSHING: A ONE PIECE MOLDED BRIDGE BEARING NEOPRENE WASHER/BUSHING. THE
BUSHING SHALL SURROUND THE ANCHOR BOLT AND HAVE A FLAT WASHER FACE TO AVOID METAL TO METAL
CONTACT. USE WASHER/BUSHING ONLY ON LIGHT-WEIGHT EQUIPMENT.
ACCEPTABLE MANUFACTURER: MASON HG HEMI GROMMET OR EQUAL
NEOPRENE PAD ISOLATORS: NEOPRENE OR NEOPRENE / STEEL / NEOPRENE PAD ISOLATORS. MINIMUM
STATIC DEFLECTION 2.5 MM (0.1") OR GREATER.
ACCEPTABLE MANUFACTURER: MASON WMSW OR EQUAL
RUBBER FLOOR MOUNTS: BRIDGE BEARING NEOPRENE MOUNTINGS. MINIMUM STATIC DEFLECTION OF 5MM
(0.2") OR GREATER AND ALL DIRECTIONAL SEISMIC CAPABILITY.
ACCEPTABLE MANUFACTURER: MASON RAA OR ND OR EQUAL
SPRING FLOOR MOUNTS: SPRING ISOLATORS BUILT INTO A DUCTILE IRON OR STEEL HOUSING TO PROVIDE ALL
DIRECTIONAL SEISMIC SNUBBING. THE SNUBBER SHALL BE ADJUSTABLE VERTICALLY AND ALLOW A MAXIMUM
OF 6MM (1/4") TRAVEL IN ALL DIRECTIONS BEFORE CONTACTING THE RESILIENT SNUBBING COLLARS. MOLDED
NEOPRENE CUP OR 1/4" (6MM) NEOPRENE ACOUSTICAL FRICTION PAD BETWEEN THE BASEPLATE AND THE
SUPPORT. SPRING DIAMETERS SHALL BE NO LESS THAN 0.8 OF THE COMPRESSED HEIGHT OF THE SPRING AT
RATED LOAD. SPRINGS SHALL HAVE A MINIMUM ADDITIONAL TRAVEL TO SOLID EQUAL TO 50% OF THE RATED
DEFLECTION.
ACCEPTABLE MANUFACTURER: MASON SSLFH OR EQUAL
SPRING HANGERS: HANGERS SHALL CONSIST OF RIGID STEEL FRAMES CONTAINING MINIMUM 32MM (1 1/4")
THICK NEOPRENE ELEMENTS AT THE TOP AND A STEEL SPRING SEATED IN A STEEL WASHER REINFORCED
NEOPRENE CUP ON THE BOTTOM. PROVIDE A COMBINATION RUBBER AND STEEL REBOUND WASHER AS THE
SEISMIC UPSTOP FOR SUSPENDED PIPING, DUCTWORK AND EQUIPMENT. RUBBER THICKNESS SHALL BE A
MINIMUM OF 6MM (1/4"). COLOUR CODED SPRINGS, RUST RESISTANT, PAINTED BOX TYPE HANGERS. TO
MAINTAIN STABILITY THE BOXES SHALL NOT BE ARTICULATED AS CLEVIS HANGERS NOR THE NEOPRENE
ELEMENT STACKED ON TOP OF THE SPRING.
ACCEPTABLE MANUFACTURER: MASON HD, HS OR EQUAL
ALTERNATE VIBRATION ISOLATION ACCEPTABLE MANUFACTURERS, KORFUND, VIBRO-ACOUSTICS
3. EXECUTION
3.1 PAINTING REPAIRS AND RESTORATION
DO PAINTING IN ACCORDANCE WITH DIVISION 09 - INTERIOR PAINTING. PRIME AND TOUCH UP MARRED
FINISHED PAINTWORK TO MATCH ORIGINAL. RESTORE TO NEW CONDITION, FINISHES WHICH HAVE BEEN
DAMAGED.
CLEAN EXPOSED BARE METAL SURFACES SUPPLIED UNDER DIVISIONS 21, 22, 23 AND 25. APPLY AT LEAST ONE
COAT OF CORROSION RESISTANT PRIMER PAINT TO ALL SUPPORTS AND EQUIPMENT FABRICATED FROM
FERROUS METAL.
3.2 DEMONSTRATION
SUPPLY TOOLS, EQUIPMENT, PERSONNEL TO DEMONSTRATE AND INSTRUCT THE OPERATING, AND
MAINTENANCE PERSONNEL IN OPERATING, CONTROLLING, ADJUSTING, TROUBLE-SHOOTING, AND SERVICING
OF ALL SYSTEMS AND EQUIPMENT DURING REGULAR WORK HOURS, PRIOR TO ACCEPTANCE.
3.3 FIRESTOPPING AND SMOKE SEALS
THE OWNER'S CONSULTANT SHALL CONDUCT MANDATORY DESTRUCTIVE REVIEWS FOR EACH TYPE OF
INSTALLATION. DESTRUCTIVE TESTING SHALL BE AT THE DISCRETION OF THE OWNER'S CONSULTANT AND
AUTHORITY HAVING JURISDICTION
ALLOW FOR DESTRUCTIVE TESTING OF 5% OF FIRE STOPPING APPLICATIONS. SHOULD INSTALLATIONS NOT
CONFORM TO MANUFACTURER'S LISTED ASSEMBLY, AN ADDITIONAL 25% OF INSTALLATIONS MAY BE
DESTRUCTIVELY TESTED AND SHOULD THERE BE MORE FAILURES, THE CONTRACTOR WILL BE RESPONSIBLE
TO REMOVE ALL FIRE STOPPING PRODUCTS AND REINSTALL PRODUCTS CORRECTLY, AT NO ADDITIONAL COST
TO THE PROJECT..
TAG ALL PENETRATIONS AND EVERY 3 METERS OF JOINT SEAL WITH PRINTED TAGS. TAGS SHALL INDICATE
PRODUCT, SYSTEM #, DATE INSTALLED, INSTALLED BY: (NAME AND PHONE NUMBER OF SUBCONTRACTOR)
AND RE-PENETRATED BY & DATE.
TAGS SHALL STATE: CAUTION! FIRESTOP - DO NOT REMOVE, PUNCTURE OR DISCONTINUE UNLESS PREPARED
TO RE-SEAL IMMEDIATELY WITH SPECIFIED PRODUCT
COMPLY WITH MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION OF THROUGH-PENETRATION JOINT
MATERIALS. WHERE POSSIBLE, USE METAL SLEEVES FOR FLOOR PENETRATIONS TO PREVENT/MITIGATE THE
CONSEQUENCES OF LEAKAGE OR FLOODING.
PERFORM UNDER THIS SECTION PATCHING AND REPAIRING OF FIRESTOP CAUSED BY CUTTING OR
PENETRATING OF EXISTING FIRESTOP SYSTEMS ALREADY INSTALLED BY OTHER TRADES.
3.4 PIPE HANGERS AND SUPPORTS
PIPE SUPPORT SPACING AND HANGER ROD DIAMETER SHALL BE:
PIPE SIZE: NPS 1/2 ROD DIAMETER 9MM (3/8”), SPACING 1.8M (6')
PIPE SIZE: NPS 3/4 TO 1½ ROD DIAMETER 9MM (3/8”), SPACING 2.4M (8')
3.5 ACCESS DOORS
PROVIDE ALL ACCESS DOORS REQUIRED TO ACCESS WORK INSTALLED BY DIVISIONS 21, 22, 23 AND 25. BE
RESPONSIBLE FOR COORDINATING LOCATIONS, CUTTING OPENING AND INSTALLING PANELS. ANY
SECONDARY SUPPORTS, BLOCKING ETC. WILL BE BY THE CEILING OR WALL CONTRACTOR. ENSURE THAT
EQUIPMENT IS WITHIN VIEW AND ACCESSIBLE FOR OPERATING, INSPECTING, ADJUSTING, SERVICING WITHOUT
USING SPECIAL TOOLS.
3.6 VIBRATION ISOLATION
NEOPRENE WASHER/BUSHING: ISOLATE VARIABLE FREQUENCY DRIVE CONTROLLER USING NEOPRENE
WASHER/BUSHING ISOLATORS OR SOFT GROMMETS SUCH THAT STRUCTURE BORNE NOISE TRANSMISSION TO
OCCUPIED SPACE IS LESS THAN AIRBORNE NOISE TRANSMISSION.
RUBBER FLOOR MOUNTS: MOUNT IN-LINE PUMPS ON TWO (2) RUBBER FLOOR MOUNT ISOLATORS UNDER EACH
SUPPORT FOOT. FOR EQUIPMENT MOUNTED ON A SLAB ON GRADE MOUNT ON RUBBER FLOOR MOUNT
ISOLATORS UNLESS OTHERWISE SPECIFIED. PROVIDE PROTECTION OF THE RUBBER ELEMENT FROM
CONTACT WITH OIL IN THE MECHANICAL ROOM.
SPRING FLOOR MOUNTS: ISOLATE ALL FLOOR OR PIER MOUNTED EQUIPMENT ON SPRING FLOOR MOUNT
ISOLATORS, UNLESS OTHERWISE SPECIFIED.
SPRING HANGERS: LOCATE ISOLATION HANGERS AS NEAR TO THE OVERHEAD SUPPORT STRUCTURE AS
POSSIBLE. INSTALLATION SHALL PERMIT HANGER BOX OR ROD TO MOVE THROUGH A 30 DEGREES ARC
WITHOUT METAL TO METAL CONTACT. ALL DISCHARGE DUCTWORK RUNS FOR A DISTANCE OF 15M (50') FROM
THE CONNECTED EQUIPMENT SHALL BE ISOLATED FROM THE BUILDING STRUCTURE BY MEANS OF SPRING
HANGERS. SPRING DEFLECTION SHALL BE A MINIMUM OF 19MM (0.75").
DIVISION 23 HVAC
1. GENERAL
1.1 GRILLES, LOUVRES AND DIFFUSERS
AIRFLOW TESTS AND SOUND LEVEL MEASUREMENT SHALL BE MADE IN ACCORDANCE WITH APPLICABLE ADC
EQUIPMENT TEST CODES, ASHRAE STANDARDS AND AMCA STANDARDS.
MANUFACTURER SHALL CERTIFY CATALOGUED PERFORMANCE AND ENSURE CORRECT APPLICATION OF AIR
OUTLET TYPES.
OUTSIDE LOUVERS SHALL BEAR AMCA SEAL FOR FREE AREA AND WATER PENETRATION.
PROJECT CONDITIONS: REVIEW REQUIREMENTS OF OUTLETS AS TO SIZE, FINISH AND TYPE OF MOUNTING
PRIOR TO SUBMITTING SHOP DRAWINGS AND SCHEDULES OF OUTLETS. POSITIONS INDICATED ARE
APPROXIMATE ONLY. CHECK LOCATIONS OF OUTLETS AND MAKE NECESSARY ADJUSTMENTS IN POSITION TO
CONFORM WITH ARCHITECTURAL FEATURES, SYMMETRY, AND LIGHTING ARRANGEMENT.
2. PRODUCTS
2.1 DUCTWORK AND ACCESSORIES
PROVIDE DUCTWORK CONSTRUCTED, REINFORCED, SEALED, AND INSTALLED TO WITHSTAND 1-½ TIMES THE
WORKING STATIC PRESSURE.
PROVIDE LOW PRESSURE DUCTWORK 500 PA (2” W.G.) FOR SUPPLY DUCTWORK AND PLENUMS ON SYSTEMS
WITHOUT TERMINAL MIXING BOXES OR AIR VALVES, SUPPLY DUCTWORK DOWNSTREAM FROM TERMINAL
MIXING BOXES OR AIR VALVES, OUTDOOR AIR DUCTWORK AND PLENUMS, RETURN AIR DUCTWORK AND
PLENUMS, EXHAUST AND RELIEF AIR DUCTWORK AND PLENUMS, UNLESS NOTED OTHERWISE.
LOW PRESSURE INSULATED FLEXIBLE DUCTWORK SHALL BE EQUAL TO THERMAFLEX TYPE M-KC.
PROVIDE MEDIUM PRESSURE DUCTWORK TO 1000 PA (4”W.G.) FOR SUPPLY AIR DUCTWORK DOWNSTREAM
FROM SUPPLY AIR HANDLING UNITS DISCHARGE, TO TERMINAL MIXING BOXES OR AIR VALVES, EXHAUST AND
RETURN AIR DUCTWORK DOWNSTREAM OF RETURN/EXHAUST AIR VALVES TO THE RETURN/EXHAUST FANS
AND DISCHARGE DUCTWORK FROM THE RETURN/EXHAUST FANS TO THE AIR HANDLING UNITS AND/OR RELIEF
OPENING.
2.2 DUCT SEALING
DUCT SEALING LOW PRESSURE DUCTWORK 500 PA (2” W.G.) AND UNDER SHALL BE SMACNA SEAL CLASS A.
SEAL ALL SUPPLY, RETURN AND EXHAUST DUCT JOINTS, LONGITUDINAL AS WELL AS TRANSVERSE JOINTS AS
FOLLOWS:
SLIP JOINTS: APPLY HEAVY BRUSH-ON HIGH PRESSURE DUCT SEALANT. APPLY SECOND APPLICATION AFTER
THE FIRST APPLICATION HAS COMPLETELY DRIED OUT. WHERE METAL CLEARANCE EXCEEDS 1.5 MM (1/16")
USE HEAVY MASTIC TYPE SEALANT.
FLANGED JOINTS: SOFT ELASTOMER BUTYL OR EXTRUDED FORM OF SEALANT BETWEEN FLANGES FOLLOWED
BY AN APPLICATION OF HEAVY BRUSH-ON HIGH PRESSURE DUCT SEALANT.
OTHER JOINTS: HEAVY MASTIC TYPE SEALANT.
DUCT SEALING MEDIUM PRESSURE DUCTWORK TO 1000 PA (4”W.G.) SHALL BE THE SAME AS 500 PA DUCTWORK
EXCEPT PROVIDE A COMBINATION OF WOVEN FABRICS AND SEALING COMPOUND FOLLOWED BY AN
APPLICATION OF HIGH PRESSURE DUCT SEALANT.
DUCT TAPES AS A SEALING METHOD ARE NOT PERMITTED, EXCEPT ON RESIDENTIAL DUCTWORK - MINIMUM 2
WRAPS OF 2” WIDE (50MM) FOIL DUCT TAPE IS ACCEPTABLE.
DO NOT INSULATE ANY SECTION OF THE DUCTWORK UNTIL IT HAS BEEN INSPECTED AND APPROVED OF DUCT
SEALANT APPLICATION, BY THE CONSULTANT.
2.3 DUCT HANGERS AND SUPPORTS
HANGERS AND SUPPORTS TO SMACNA STANDARDS.
STRAP HANGERS: OF SAME MATERIAL AS DUCT BUT NEXT SHEET METAL THICKNESS HEAVIER THAN DUCT.
MAXIMUM SIZE DUCT SUPPORTED BY STRAP HANGER: 500 MM.
HANGERS: GALVANIZED STEEL ANGLE WITH GALVANIZED STEEL RODS TO SMACNA.
TOGGLE HANGERS AND/OR STRAP HANGERS SHALL NOT BE USED.
POWER ACTUATED FASTENERS AND “DROP-IN” ANCHORS SHALL NOT BE USED.
2.4 PIPING
REFRIGERANT PIPING SHALL BE ACR COPPER.
PIPE CONNECTIONS UNLESS NOTED OTHERWISE SHALL BE: NPS 1½ AND LESS: SCREWED JOINT STEEL PIPING,
NPS 2: SCREWED JOINT FOR LIQUID SYSTEMS, WELD JOINT FOR AIR OR GAS SYSTEMS, NPS 2½ AND LARGER:
WELD OR FLANGED PIPING INCLUDING BRANCH CONNECTIONS.
USE DIELECTRIC TYPE COUPLINGS WHEN JOINING DISSIMILAR METAL PIPES.
2.5 VALVES
WHEREVER POSSIBLE ALL VALVES SHALL BE OF ONE MANUFACTURER.
GROOVED VALVES SHALL BE OF THE SAME MANUFACTURER AS THE ADJOINING COUPLINGS.
PROVIDE VALVES WITH MANUFACTURER'S NAME AND PRESSURE RATING CLEARLY MARKED ON OUTSIDE OF
BODY. ALL VALVES MUST BE SUITABLE IN ALL RESPECTS FOR SERVICE USED.
ALL VALVES SHALL HAVE A PROVINCIAL CRN NUMBER WHICH IS CURRENT.
2.6 DUCT INSULATION
EXPOSED RECTANGULAR DUCTS: EXTERNAL RIGID INSULATION, SERVICE TEMPERATURE 5°C TO 232°C (41°F
TO 450°F), MINERAL FIBER BOARD FOR LOW AND MEDIUM TEMPERATURE APPLICATIONS, ALL SERVICE
ALUMINUM FOIL-SCRIM KRAFT (FSK) VAPOUR BARRIER JACKET WITH GLASS FIBRE REINFORCEMENT, FACTORY
APPLIED. DENSITY 36KG/M3 (2.25 PCF), MINIMUM RSI 0.76/25MM (R 4.3/IN)
ROUND DUCTS AND CONCEALED RECTANGULAR DUCTS: EXTERNAL FLEXIBLE INSULATION, SERVICE
TEMPERATURE 5°C TO 232°C (41°F TO 450°F), GLASS FIBER OR MINERAL FIBER FLEXIBLE BLANKET FOR LOW
AND MEDIUM TEMPERATURE APPLICATIONS, ALL SERVICE ALUMINUM FOIL-SCRIM KRAFT (FSK) VAPOUR
BARRIER JACKET WITH GLASS FIBRE REINFORCEMENT, FACTORY APPLIED. DENSITY 12KG/M3 (0.75PCF),
MINIMUM RSI 0.49/25MM (R 2.8/IN) (INSTALLED)
ACOUSTIC LINING DUCTS: INTERNAL FLEXIBLE DUCT LINER, FLEXIBLE MINERAL FIBER BLANKET, FOR LOW AND
MEDIUM TEMPERATURE ACOUSTICAL APPLICATIONS, AIRSTREAM SURFACE FACED WITH A BLACK MAT
BONDED TO THE FIBREGLASS SUBSTRATE, AIR VELOCITY RATING 25.4 M/S (5,000 FT/MIN). DENSITY 24KG/M3
(1.5 PCF), MINIMUM RSI 0.74/25MM (R 4.2/IN)
ACOUSTIC LINING PLENUMS: INTERNAL RIGID DUCT LINER, RIGID MINERAL FIBER BOARD, FOR LOW AND
MEDIUM TEMPERATURE ACOUSTICAL APPLICATIONS, AIRSTREAM SURFACE FACED WITH A BLACK MAT
BONDED TO THE FIBREGLASS SUBSTRATE, AIR VELOCITY RATING 25.4 M/S (5,000 FT/MIN). DENSITY 48KG/M3 (3
PCF), MINIMUM RSI 0.76/25MM (R 4.3/IN)
2.7 DUCTWORK FINISH JACKETS
THERMOCANVAS JACKET: FIRE RATED, 170G (6 OZ) FIRE RETARDANT CANVAS JACKET FOR COVERING
MECHANICAL INSULATION INDOORS, 25/50 FIRE CLASS, PLAIN WAVE COTTON, NO DYES.
UTILITY FINISH: OVER RIGID INSULATION FOR RECTANGULAR DUCTWORK AND FLEXIBLE INSULATION FOR
ROUND DUCTWORK. APPLY CONTINUOUS METAL CORNER BEAD TO ALL CORNERS. ADHERE VAPOR RETARDER
TAPE OVER ALL JOINTS AND BREAKS IN VAPOR RETARDER, AND AT ALL CORNERS.
ALUMINUM JACKET: 51 MIL (22 GA.) THICK STUCCO OR SMOOTH ALUMINUM JACKETING WITH LONGITUDINAL
SLIP JOINTS AND 50MM (2") END LAPS WITH FACTORY APPLIED PROTECTIVE LINER ON INTERIOR SURFACE.
2.8 PIPING FINISH JACKETS
THERMOCANVAS JACKET: FIRE RATED, 170G (6 OZ) FIRE RETARDANT CANVAS JACKET FOR COVERING
MECHANICAL INSULATION INDOORS, 25/50 FIRE CLASS, PLAIN WAVE COTTON, NO DYES.
PVC FINISHING JACKET: WHITE, UV RESISTANT, FOR INDOOR OR OUTDOOR APPLICATIONS, 25/50 FIRE CLASS,
MINIMUM 0.50 MM (0.02”) THICK.
ALUMINUM JACKET: 0.51 MM (22 GA.) THICK STUCCO OR SMOOTH ALUMINUM JACKETING WITH LONGITUDINAL
SLIP JOINTS AND 50MM (2") END LAPS WITH FACTORY APPLIED PROTECTIVE LINER ON INTERIOR SURFACE.
2.9 GRILLES, LOUVRES AND DIFFUSERS
ACCEPTABLE MANUFACTURES FOR AIR TERMINALS: E.H. PRICE, TITUS, ANEMOSTAT, NAILOR.
ACCEPTABLE MANUFACTURERS FOR LOUVRES: AIROLITE, PENN, AIRSTREAM, WEST VENT, NAILOR, RUSKIN.
PROVIDE BAFFLES TO DIRECT AIR AWAY FROM WALLS, COLUMNS OR OTHER OBSTRUCTIONS WITHIN THE
RADIUS OF DIFFUSER OPERATION.
PROVIDE PLASTER FRAME FOR DIFFUSERS LOCATED IN PLASTER SURFACES AND ANTI-SMUDGE FRAMES OR
PLAQUES ON DIFFUSERS LOCATED IN ROUGH TEXTURED SURFACES SUCH AS ACOUSTICAL PLASTER.
PROVIDE 30 MM MARGIN FRAME ON GRILLES WITH COUNTERSUNK SCREW HOLES.
PROVIDE OPPOSED BLADE BALANCE DAMPER, ACCESSIBLE FROM GRILLE FACE ON ALL GRILLES LOCATED IN
DRYWALL CEILINGS OR BULKHEADS.
ALL GRILLES AND DAMPERS SHALL BE ALUMINUM IN WET AREAS (I.E. SHOWERS, AQUATIC AREAS,
DISHWASHING ETC.)
IN GYMNASIUM, AQUATIC CENTRES, FRONT BLADES SHALL BE FRONT PIVOTED, WELDED IN PLACE OR
SECURELY FASTENED TO BE IMMOBILE.
FABRICATE GOOSENECKS OF MINIMUM 1.3 MM (18 GA.) GALVANIZED STEEL. MOUNT ON MINIMUM 300 MM (12
IN.) HIGH CURB BASE WHERE SIZE EXCEEDS 225 MM X 225 MM (9 IN. X 9 IN).
REFER TO GRILLES AND DIFFUSER SCHEDULE FOR TYPES AND CAPACITIES.
2.10 EQUIPMENT
ALL EQUIPMENT SHALL BE CSA APPROVED FOR ITS INTENDED USE.
INLINE BELT DRIVEN EXHAUST FAN: WHEEL STATICALLY AND DYNAMICALLY BALANCED TO AMCA STANDARD,
TEFC MOTORS, PERMANENTLY LUBRICATED, HEAVY DUTY BEARINGS OR PILLOW BLOCK BALL BEARINGS.
BEARING SHALL BE SELECTED FOR A MINIMUM L10 LIFE IN EXCESS OF 100,000 HOURS. (EQUIVALENT TO L50
AVERAGE LIFE OF 500,000 HOURS). HEAVY GAUGE GALVANIZED STEEL HOUSING. RECTANGULAR
CONSTRUCTION INCLUDING RECTANGULAR DUCT MOUNTING COLLARS. DRIVE FRAME ASSEMBLIES SHALL BE
CONSTRUCTED OF HEAVY GAUGE STEEL AND MOUNTED ON VIBRATION ISOLATORS. ADJUSTABLE BELT DRIVE,
PULLEYS, AND KEYS OVERSIZED FOR A MINIMUM OF 150 PERCENT OF DRIVEN HORSEPOWER. PROVIDE A
MOTORIZED DAMPER TO PREVENT OUTSIDE AIR FROM ENTERING BACK INTO THE BUILDING WHEN FAN IS OFF.
PROVIDE A NEMA 4 DISCONNECT SWITCH WIRED FROM FAN MOTOR TO JUNCTION BOX.
ACCEPTABLE MANUFACTURERS: COOK, GREENHECK
CAPACITY AS SCHEDULED.
EXHAUST FAN: CEILING MOUNT, ENERGY STAR® RATED WITH BUILT-IN SPEED SELECTOR. THE MOTOR SHALL
BE TOTALLY ENCLOSED, FOUR POLE CONDENSER TYPE ENGINEERED TO RUN CONTINUOUSLY. POWER
RATING SHALL BE 120V/60HZ. HOUSING MATERIAL SHALL BE NO LESS THAN 26 GAUGE GALVANIZED STEEL
WITH RUST PROOF EPOXY AND
FORWARD CURVED CENTRIFUGAL WHEEL, GALVANIZED STEEL OR CALCIUM CARBONATE FILLED
POLYPROPYLENE, STATICALLY AND DYNAMICALLY BALANCED TO AMCA STANDARDS.
ACCEPTABLE MANUFACTURERS: PANASONIC
CAPACITY AS SCHEDULED.
HORIZONTAL CONCEALED FAN COIL: CABINET SHALL BE MADE OF HEAVY GAUGE GALVANIZED STEEL. THE
INTERIOR SURFACES SHALL BE LINED WITH 12MM (½") THICK STANDARD FIBERGLASS INSULATION. A HEAVY
GAUGE GALVANIZED STEEL PLENUM SHALL ENCLOSE THE BLOWER/MOTOR ASSEMBLY WITH BOTTOM OR
REAR RETURN. PROVIDE A DUCTED COLLAR FOR SUPPLY DUCT CONNECTION. PROVIDE DISPOSABLE
PLEATED FILTERS TO MERV 8 RATING.
ACCEPTABLE MANUFACTURERS: INTERNATIONAL ENVIRONMENTAL, TRANE, MCQUAY, WILLIAMS, ENVIRO TEC
CAPACITY AS SCHEDULED.
3. EXECUTION
3.1 DUCTWORK AND ACCESSORIES
FABRICATE DUCTWORK IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS - METAL AND
FLEXIBLE, NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS,
AND NFPA 90B STANDARD FOR THE INSTALLATION OF WARM AIR HEATING AND AIR-CONDITIONING SYSTEMS
PRIOR TO FABRICATION OF DUCTWORK, CHECK ALL CEILING SPACES AND HEIGHTS AND CONFLICTS WITH
OTHER TRADES.
DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS. FOR ACOUSTICALLY LINED OR INTERNALLY
INSULATED DUCTS ALLOW FOR INSULATION THICKNESS AND MAINTAIN INTERIOR CLEAR DIMENSIONS
INDICATED.
CONNECT OUTLET TERMINALS TO LOW PRESSURE DUCTS WITH 900MM (36”) MAXIMUM LENGTH OF STRETCHED
FLEXIBLE DUCT. HOLD IN PLACE WITH STRAP OR CLAMP, CAULK SEALED. DO NOT USE FLEXIBLE DUCT TO
CHANGE DIRECTIONS.
PROVIDE A FLEXIBLE CONNECTION WHERE LOW PRESSURE DUCTS ARE CONNECTED TO FAN EQUIPMENT,
TERMINAL BOXES OR ANY OTHER APPARATUS. JOINT SHALL BE SCREWED OR BOLTED FLEXIBLE GASKETED
JOINT, MINIMUM 50MM (2”) WIDE.
PROVIDE FIRE DAMPERS WHERE DUCTS CROSS FIRE SEPARATIONS. FIRE DAMPERS SHALL BE ULC LISTED
AND “DYNAMIC”; RATED TO CLOSE UNDER AIRFLOW. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE
SEPARATION RATINGS AND LOCATIONS.
PROVIDE BALANCING DAMPERS WHERE INDICATED ON DRAWINGS AND AT POINTS ON LOW PRESSURE
SUPPLY, RETURN AND EXHAUST DUCTS WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS.
MODIFY CEILING SYSTEM WHERE REQUIRED TO ACCOMMODATE GRILLES AND DIFFUSERS.
SIZE ROUND DUCTS, INSTALLED IN PLACE OF RECTANGULAR DUCTS, FROM ASHRAE TABLE OF EQUIVALENT
RECTANGULAR AND ROUND DUCTS. NO VARIATION OF DUCT CONFIGURATION OR SIZES PERMITTED EXCEPT
BY PERMISSION FROM THE CONSULTANT.
EXPOSED ROUND DUCTWORK TO BE SPIRAL LOCK SEAM TYPE ONLY.
PROVIDE DUCT HANGERS AND SUPPORTS IN ACCORDANCE WITH SMACNA MANUALS.
CONFIRM THE EXISTING BASE BUILDING STANDARDS PRIOR TO SUBMITTING TENDER.
DUCTWORK SHALL BE GALVANIZED STEEL UNLESS NOTED OTHERWISE.
3.2 DUCT HANGERS AND SUPPORTS
DUCT SUPPORT SHALL BE:
UP TO 750MM DUCT SIZE: ANGLE SIZE 25X25X3 MM WITH 6MM ROD SIZE
751 TO 1050MM DUCT SIZE: ANGLE SIZE 40X40X3 MM WITH 6MM ROD SIZE
1051 TO 1500MM DUCT SIZE: ANGLE SIZE 40X40X3 MM WITH 10MM ROD SIZE
1501 TO 2100MM DUCT SIZE: ANGLE SIZE 50X50X3 MM WITH 10MM ROD SIZE
2101 TO 2400MM DUCT SIZE: ANGLE SIZE 50X50X5 MM WITH 10MM ROD SIZE
2401 AND OVER DUCT SIZE: ANGLE SIZE 50X50X6 MM WITH 10MM ROD SIZE
UPPER HANGER ATTACHMENTS SHALL BE:
FOR CONCRETE: MANUFACTURED CONCRETE INSERTS.
FOR STEEL JOIST: MANUFACTURED JOIST CLAMP.
FOR STEEL BEAMS: MANUFACTURED BEAM CLAMPS.
3.3 DUCT INSULATION
INSTALL ALL DUCTWORK INSULATION TO THE THERMAL INSULATION ASSOCIATION OF CANADA BEST
PRACTICES GUIDE.
DUCT INSULATION MINIMUM THICKNESS TABLE (CLIMATIC ZONE 5)
NOTE (1): AIR TEMPERATURES 15°C TO 49°C (60°F TO 120°F).
NOTE (2): PROVIDE 38MM (1-½”) FLEXIBLE DUCT INSULATION ON ALL EXHAUST AIR DUCTWORK FROM OUTSIDE
WALL OR ROOF TO DAMPER BUT A MINIMUM OF 1.5 M (5 FT.) INSIDE BUILDING.
NOTE (3): MIXED AIR INCLUDES TEMPERED AIR DOWNSTREAM OF HEAT RECOVERY UNITS.
NOTE (4): PLENUMS LOCATED OUTSIDE THE BUILDING SHALL BE INSULATED TO THE VALUES LISTED IN THE
EXTERIOR COLUMN.
NOTE (5): PROVIDES 1 HOUR FIRE RATING. THICKNESS SHALL BE DOUBLED FOR 2 HOUR APPLICATIONS.
NOTE (6): FACTORY INSTALLED DUCTWORK AND PLENUMS PROVIDED WITH EQUIPMENT NEED NOT COMPLY
WITH THIS TABLE PROVIDED THEY MEET THE REQUIREMENTS OF THE RELEVANT CSA STANDARD FOR THAT
EQUIPMENT AND IS INSULATED TO RSI 0.58 (R3.3) OR GREATER. REFER TO NECB ARTICLE 5.2.12.1 FOR
RELEVANT CSA STANDARDS.
3.4 DUCT FINISHES TABLE
INDOORS CONCEALED; FACTORY FINISH
INDOORS EXPOSED IN MECHANICAL ROOM AND ELSEWHERE; CANVAS JACKET AS PER TIAC STANDARD CRF/1 -
CRD/1
INDOORS, EXPOSED IN UTILITY AREAS, PARKADE, ETC.; UTILITY FINISH AS PER TIAC CODE CRF/2 - CRD/2
INDOOR EXPOSED IN UTILITY AREAS, PARKADE, ETC. PROVIDE A UTILITY FINISH AS PER TIAC CODE CRF/2 AND
CRD/2
OUTDOORS; ALUMINUM JACKET AS PER TIAC CODE CRF/3 - CRD/3
3.5 PIPING FINISH SCHEDULE
INDOORS CONCEALED; FACTORY FINISH
INDOORS EXPOSED IN MECHANICAL ROOM AND ELSEWHERE; CANVAS JACKET
INDOORS, EXPOSED IN UTILITY AREAS, PARKADE, ETC.; PVC JACKET
OUTDOORS; ALUMINUM JACKET
3.6 GRILLES, LOUVRES AND DIFFUSERS
PAINT DUCTWORK VISIBLE BEHIND AIR OUTLETS MATTE BLACK.
ALL AIR OUTLETS MOUNTED IN A T-BAR CEILING SHALL BE SEISMICALLY RESTRAINED BY EITHER SECURE
ATTACHMENT TO SOLID DUCTWORK, WHICH IS BRACED AT THE OUTLET OR WIRE HANGERS ATTACHED TO
STRUCTURE. WIRE HANGERS SHALL BE A MINIMUM OF TWO (2) PER OUTLET AND ONE PER 1200 MM LENGTH.
AIR OUTLETS OTHER THAN T-BAR MOUNTING MUST BE SECURELY ATTACHED TO THE BUILDING ELEMENTS.
DIVISION 25 INTEGRATED AUTOMATION
1. GENERAL
1.1 SECTION SCOPE
PROVIDE A COMPLETE SYSTEM OF AUTOMATIC CONTROLS TO MATCH THE BASE BUILDING STANDARD WITH
REGARD TO CONTROL DEVICES, COMPONENTS, WIRING AND MATERIALS. ALL CONTROL WORK ASSOCIATED
WITH THE WORK OF DIVISIONS 22 AND 23.
NOT ALL REQUIRED POINTS SHOWN ON DRAWINGS, REFER TO SEQUENCE OF OPERATIONS FOR REQUIRED
NEW POINTS.
1.2 RELATED REQUIREMENTS
THIS SECTION OF THE SPECIFICATION FORMS PART OF THE CONTRACT DOCUMENTS AND IS TO BE READ,
INTERPRETED AND COORDINATED WITH ALL OTHER PARTS. FOR GENERAL CONDITIONS REFER TO HEATING,
VENTILATION AND AIR CONDITIONING (HVAC) SECTION.
1.3 CODE COMPLIANCE
ALL WORK SHALL COMPLY WITH CURRENT EDITIONS OF THE NATIONAL, PROVINCIAL AND MUNICIPAL CODES,
STANDARDS, ACTS AND BYLAWS AND WILL MEET THE REQUIREMENTS OF THE AUTHORITY HAVING
JURISDICTION.
1.4 ACCEPTABLE CONTRACTORS
ALL CONTROLS WORK IS TO BE DONE BY THE BASE BUILDING CONTRACTOR ESC.
1.5 EXAMINATION OF EXISTING SYSTEM
THIS PROJECT INVOLVES RENOVATION TO AN EXISTING CONTROL SYSTEM. THE CONTRACTOR SHALL
INSPECT THE SYSTEM PRIOR TO TENDER CLOSE AND INCLUDE IN HIS BID ALL CONTROL COMPONENTS
REQUIRED TO PROVIDE A FULLY OPERATIONAL SYSTEM INCLUDING REPLACEMENT OF EXISTING DEFECTIVE
COMPONENTS WHERE NOTED IN THE PROJECT DOCUMENTS.
1.6 DESIGN REQUIREMENTS
SUPPLY SUFFICIENT PROGRAMMABLE CONTROLLERS OF TYPES TO MEET PROJECT REQUIREMENTS.
QUANTITY AND POINTS CONTENTS AS REVIEWED BY CONSULTANT PRIOR TO INSTALLATION.
NOT ALL REQUIRED POINTS SHOWN ON DRAWINGS, REFER TO SEQUENCE OF OPERATIONS FOR ALL REQUIRED
POINTS.
PROVIDE UTILITY POWER TO EMCS AS INDICATED.
2. PRODUCTS
2.1 THERMOSTATS
ALL THERMOSTATS TO BE WALL MOUNTED [TO MATCH EXISTING BASE BUILDING MOUNTING HEIGHT] UNLESS
SPECIFICALLY NOTED OTHERWISE.
ALL THERMOSTATS, EXISTING AND NEW, ARE TO BE CALIBRATED PRIOR TO AIR BALANCING. CONTACT
BUILDING OWNER IF AN EXISTING THERMOSTAT NEEDS REPLACING.
2.2 CONTROL COMPONENTS
WHERE EXISTING DEVICES ARE RE-USED, VERIFY OPERATION AND RE-CALIBRATE AS REQUIRED.
REPORT ANY EXISTING CONTROL DEVICE WHICH NEED REPLACEMENT. REPLACEMENT WILL BE BY BUILDING
MANAGEMENT OR VIA CHANGE ORDER, AT THE DISCRETION OF THE OWNER.
3. EXECUTION
3.1 SEQUENCE OF OPERATION
.1 OFFICE HRV (NOT ON DDC)
.1 ADD: HRV'S WILL OPERATE AT LOW SPEED 24/7.
.2 ADD: UNIT TO BE CONTROLLED BY INTEGRAL SMART CONTROLLER.
.2 EXHAUST FANS (REVERSE-ACTING) (EF-1) (NOT ON DDC)
.1 ADD: FAN SHALL ENABLE WHEN TEMPERATURE RISES ABOVE SETPOINT 28°C (ADJUSTABLE).
.2 ADD: FAN SHALL DISABLE WHEN TEMPERATURE FALLS BELOW SETPOINT 28°C (ADJUSTABLE).
.3 ADD: FAN TO BE CONTROLLED BY LINE VOLTAGE REVERSE ACTING THERMOSTAT.
.3 ELECTRIC FORCE FLOW HEATER/UNIT HEATER (NOT ON DDC)
.1 ADD: SYSTEM TO BE TURN OFF AND TURN OFF THROUGH INTEGRATED THERMOSTAT.
.4 SPLIT AC (AC-1 TO AC-11)
.1 ADD: UNIT SHALL OPERATE IN OCCUPIED HOURS BASED ON A WEEKLY SCHEDULE
(PROGRAMMABLE).
.2 ADD: THE ROOM TEMPERATURE SETPOINT SHALL ALSO OPERATE ON A SCHEDULE. DEPENDING
ON THE ROOM USAGE (BASED ON DIFFERENT TIME SCHEDULES) THE SETPOINT SHALL BE
AUTOMATICALLY ADJUSTED TO MEET THE ROOM DEMANDS.
.3 ADD: THE COOLING SYSTEM SHALL COME ON WHEN THE ROOM TEMPERATURE FALLS 1°C
(ADJUSTABLE) BELOW THE ROOM TEMPERATURE SETPOINT AS SET BY THE ROOM THERMOSTAT.
.4 ADD: ONCE THE SPACE TEMPERATURE RISES BELOW THE ROOM TEMPERATURE SETPOINT THE
COOLING SYSTEM WILL TURN OFF. A MINIMUM RUN TIME OF 5 MINUTES (ADJUSTABLE) SHALL BE
SET TO AVOID COMPRESSOR SHORT CYCLING.
.5 ADD: ON A CALL FOR COOLING THE RESPECTIVE HEATING SYSTEM SERVING THAT ZONE IS TO BE
LOCKED OUT. (BASEBOARD, FAN COIL OR RTU)
.6 UNITS SHALL ENABLE/DISABLE USING THE PROVIDED SAMSUNG EXTERNAL CONTACT MODULE.
.5 RTU (HV-1, HV-2, HV-3)
.1 START-UP MODE:
.1 UNIT SHALL OPERATE IN OCCUPIED HOURS BASED ON A WEEKLY SCHEDULE
(PROGRAMMABLE).
.2 THE ROOM TEMPERATURE SETPOINT SHALL ALSO OPERATE ON A SCHEDULE. DEPENDING ON
THE ROOM USAGE THE SETPOINT SHALL BE AUTOMATICALLY ADJUSTED TO MEET THE ROOM
DEMANDS. FOR EXAMPLE THE SETPOINT SHALL BE SET TO 18°C WHEN THE ROOM IS BEING
USED FOR EXERCISE. THE SETPOINT SHALL CHANGE AT THE START OF THE SCHEDULED
PERIOD, BUT WILL REMAIN MANUALLY ADJUSTABLE AT THE ROOM THERMOSTAT.
.3 DELETE: THE SYSTEM SHALL INCORPORATE AN OPTIMUM START HEATING ROUTINE THAT
WILL START THE UNIT BEFORE AN OCCUPIED PERIOD TO HAVE THE SPACE AT THE SETPOINT
AT THE START OF OCCUPANCY.
.4 ADD: DURING HEATING MONTHS, HEATING OPTIMUM START CONTROLLER SHALL INITIATE
STARTUP PRIOR TO SCHEDULE TO BRING THE AVERAGE SPACE TEMPERATURE TO SETPOINT
IN THE MINIMUM AMOUNT OF TIME. MAXIMUM OPTIMUM START TIME SHALL BE 2 HOURS
(ADJUSTABLE) PRIOR TO SCHEDULED START. OUTDOOR AIR DAMPER SHALL BE CLOSED.
.5 ADD: DURING COOLING MONTHS, COOLING OPTIMUM START CONTROLLER SHALL INITIATE
STARTUP PRIOR TO SCHEDULE TO BRING THE AVERAGE SPACE TEMPERATURE TO SETPOINT
IN THE MINIMUM AMOUNT OF TIME. MAXIMUM OPTIMUM START TIME SHALL BE 3 HOURS
(ADJUSTABLE) PRIOR TO SCHEDULED START. IF THE OUTDOOR AIR TEMPERATURE IS 10ºC
BELOW THE AVERAGE SPACE TEMPERATURE AND THE SPACE TEMPERATURE IS 5ºC ABOVE
THE SETPOINT, THE DAMPERS SHALL BE SET TO FULL OUTDOOR AIR. IF FREE COOLING IS
NOT AVAILABLE AND THE OUTDOOR AIR TEMPERATURE IS GREATER THAN 16ºC, MECHANICAL
COOLING SHALL BE USED.
.2 OCCUPIED MODE:
.1 THE SUPPLY FAN SHALL RUN CONTINUOUSLY DURING OCCUPIED PERIODS. DELETE: ONCE
SUPPLY FAN OPERATION IS CONFIRMED, TEMPERATURE CONTROL SHALL BE ENABLED.
.2 ADD: ONCE THE SUPPLY FAN OPERATION IS CONFIRMED VIA CURRENT SENSOR, THE
MECHANICAL COOLING OR GAS HEATING SHALL BE ALLOWED TO OPERATE.
.3 THE SUPPLY AIR TEMPERATURE SHALL BE RESET DEPENDING ON THE VARIANCE OF THE
ROOM TEMPERATURE FROM THE ROOM TEMPERATURE SETPOINT.
.4 DELETE: HEATING AND FREE COOLING SHALL BE MODULATED IN SEQUENCE TO ACHIEVE THE
SUPPLY AIR TEMPERATURE SETPOINT. SIMULTANEOUS HEATING AND COOLING SHALL NOT
OCCUR AND THE TRANSITION FROM HEATING TO COOLING SHALL NOT EFFECT OCCUPANT
COMFORT.
.5 ADD: ON A CALL FOR COOLING, THE FACTORY ECONOMIZER SHALL MODULATE IN SEQUENCE
WITH THE MECHANICAL COOLING TO MAINTAIN THE COOLING TEMPERATURE SETPOINT. A
MINIMUM RUN TIME OF 5 MINUTES (ADJUSTABLE) SHALL BE SET TO AVOID COMPRESSOR
SHORT CYCLING.
.6 ADD: ON A CALL FOR COOLING FROM HV-2, THE BASEBOARD HEATERS SERVING THE BIRCH,
ARBUTUS AND CEDAR ROOMS ARE TO BE LOCKED OUT.
.7 ADD: ON A CALL FOR COOLING FROM HV-3, THE BASEBOARD HEATERS SERVING THE LOBBY
ARE TO BE LOCKED OUT.
.8 ADD: ON A CALL FOR HEATING, THE GAS HEATING SHALL CYCLE TO MAINTAIN THE HEATING
TEMPERATURE SETPOINT.
.9 IF THE OUTSIDE AIR TEMPERATURE IS MORE THAN THE ROOM TEMPERATURE THEN FREE
COOLING WILL BE DISABLED AND THE OUTSIDE AIR DAMPER SHALL BE AT MINIMUM POSITION.
.10 IF THE VENTILATION OVERRIDE BUTTON IN THE STORAGE ROOM IS PRESSED, THE OUTSIDE
AIR DAMPER WILL GO TO 100% OUTSIDE AIR (UNITS HV1 AND HV2 ONLY). THIS OVERRIDE WILL
LAST FOR 2 HOURS (ADJUSTABLE) BEFORE RESETTING. THE OVERRIDE WILL BE INDICATED
BY THE PUSHBUTTON LIGHTING UP.
.3 UNOCCUPIED MODE:
.1 THE MIXING DAMPERS SHALL BE IN FULL RE-CIRCULATION POSITION. THE SUPPLY FAN WILL
RUN ONLY IF THE SPACE TEMPERATURE IS BELOW THE NIGHT SET BACK TEMPERATURE
SETTING OF 17°C (ADJUSTABLE).
.2 IF THE ON OVERRIDE BUTTON ON THE WALL MOUNTED THERMOSTAT IS PRESSED, THE UNIT
WILL GO INTO OCCUPIED MODE. IF THE OFF OVERRIDE BUTTON IS PRESSED THE UNIT WILL
RETURN TO UNOCCUPIED MODE. THIS OVERRIDE WILL LAST FOR 2 HOURS (ADJUSTABLE)
BEFORE RESETTING. THE OVERRIDE WILL BE INDICATED BY THE WORD “ON” APPEARING ON
THE THERMOSTAT'S LCD DISPLAY FOR 10 SECONDS AFTER THE OVERRIDE HAS BEEN
ENABLED.
.4 ALARMS:
.1 SUPPLY FAN FAILURE ALARM
.2 DELETE: RETURN FAN FAILURE ALARM (HV-1 AND HV-2 ONLY)
.3 SUPPLY AIR TEMPERATURE OUT OF RANGE ALARM
.4 ROOM TEMPERATURE OUT OF RANGE ALARM
.6 ELECTRIC RADIANT PANELS
.1 OCCUPIED MODE:
.1 THE ELECTRIC RADIANT PANELS SHALL COME ON WHEN THE ROOM TEMPERATURE FALLS 1°C
(ADJUSTABLE) BELOW THE ROOM TEMPERATURE SETPOINT AS SET BY THE ROOM
THERMOSTAT.
.2 ONCE THE SPACE TEMPERATURE RISES ABOVE THE ROOM TEMPERATURE SETPOINT THE
ELECTRIC RADIANT PANEL WILL TURN OFF.
.3 ADD: ON A CALL FOR HEATING THE RESPECTIVE AC SYSTEM SERVING THAT ZONE IS TO BE
LOCKED OUT.
.2 UNOCCUPIED MODE:
.1 THE ELECTRIC RADIANT PANELS SHALL COME ON WHEN THE ROOM TEMPERATURE FALLS 1°C
(ADJUSTABLE) BELOW THE NIGHT SETBACK SETPOINT OF 17°C(ADJUSTABLE).
.2 ONCE THE SPACE TEMPERATURE RISES ABOVE THE NIGHT SETBACK SETPOINT THE
ELECTRIC RADIANT PANEL WILL TURN OFF.
.3 ADD: ON A CALL FOR HEATING THE RESPECTIVE AC SYSTEM SERVING THAT ZONE IS TO BE
LOCKED OUT.
.7 KITCHEN AIR SYSTEMS
.1 GENERAL:
.1 THE KITCHEN MAKE-UP AIR UNIT AND THE KITCHEN EXHAUST FAN ARE BOTH CONTROLLED BY
THE SAME MANUAL WALL SWITCH AND MUST BE TURNED ON AND OFF MANUALLY.
.2 THE DDC SYSTEM MONITORS THE KITCHEN ROOM TEMPERATURE AND THE STATUS OF THE
MAKE-UP AIR UNIT AND THE EXHAUST FAN.
.3 ADD: WHEN COOLING STATUS FROM KITCHEN AIR CONDITIONING SYSTEM IS ENABLED THE
MAKE-UP AIR UNIT HEATING SECTION IS TO BE LOCKED OUT.
.2 ALARMS:
.1 KITCHEN ROOM TEMPERATURE ALARM
.2 MAKE-UP AIR UNIT AND EXHAUST FAN STATUS NOT THE SAME
PROJECT NO.
DRAWING TITLE:
DATE
CHECKED BY
DRAWN BY
PROJECT TITLE:
SCALE
DRAWING NO.
CENTURY HOUSEAIR CONDITIONINGSYSTEM ADDITION
PROJECT ADDRESS:
COPYRIGHT RESERVEDThis drawing and design is the property of the designer to be used onlyfor the project named below. This page or any portion thereof shallonly be reproduced with express written permission.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS ANDREPORT ALL ERRORS AND OMISSIONS TO THE CONSULTANT PRIOR TOCOMMENCING THE WORK.
THESE DRAWINGS ARE NOT TO BE SCALED.
620 EIGHTH STREETNEW WESTMINSTER, BC
DESCRIPTION
2019.01.18
DATEREV.
ISSUED FOR COORDINATION1.
SEAL:
CONSULTANT:
108b-012-18
JAN 01, 2019
CALGARYT. 403-252-2333F. 403-253-3324710 - 1122 4TH STREET SWCALGARY, AB T2R 1M1
VICTORIAT. 250-382-5999F. 250-382-5998721 JOHNSON STVICTORIA, BC V8W 1M8
VANCOUVERT. 604-684-5995F. 604-684-59931100 - 808 W HASTINGS STVANCOUVER, BC V6C 2X4
A.J.M.
R.A.O.
2019.01.24 ISSUED FOR COORDINATION2.
2019.02.01 ISSUED FOR COORDINATION3.
2019.03.25 ISSUED FOR TENDER4.
MECHANICALSPECIFICATION
M3.01
N.T.S.