test & measurement radio communications audio visual · 2016-04-14 · test & measurement...

24
Update Catalogue Mid 06’ Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual Your Total Technology Resource // MOTOROLA TWO WAY RADIO SALES // SATELLITE PHONES // BROADBAND COMMUNICATIONS SOLUTIONS // POWER MEASUREMENT AND ANALYSIS // ENVIRONMENT, HEALTH & SAFETY // AUDIO VISUAL INTEGRATION // INFINITE PLANK TECHNOLOGY // DISPLAYS AND EVENTS // DIGITAL PRESENTATIONS // VIDEO WALLS

Upload: others

Post on 12-Mar-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

UpdateCatalogue Mid 06’

Test & Measurement Radio Communications Audio Visual

Test & Measurement

Radio Communications

Audio Visual

Your Total Technology Resource

// MOTOROLA TWO WAY RADIO SALES

// SATELLITE PHONES

// BROADBAND COMMUNICATIONS SOLUTIONS

// POWER MEASUREMENT AND ANALYSIS

// ENVIRONMENT, HEALTH & SAFETY

// AUDIO VISUAL INTEGRATION

// INFINITE PLANK TECHNOLOGY

// DISPLAYS AND EVENTS

// DIGITAL PRESENTATIONS

// VIDEO WALLS

Page 2: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

Test & Measurement

Visit our website - www.trcorporation.com

General Electronic Test EquipmentProbes & AccessoriesMegger DH2-6 Test Lead, 6 metre long for 10Amps Micro Ohm MetersMEG,DH2-6M AUDuplexhandspikes(2)withspringloadedhelicalcontactstestleadsuitablefor any 10AµΩ meters (like MEG,DLRO10, MEG,DLRO10X, CRO,DO7 and CHK,LMO5), Used for 4 terminal measurements with low resistance Ω meters, double, individually sprung, hardened and nickel plated, spike prods for good contact. Potential lead and spike marked for easy identification, suitable for use in potentially corrosive conditions. Body moulding resistant to aviation “Phosphate ester” fluids. Current rating: 20A max. Working voltage: 30Vac/dc. Resistance of leads: each lead 20mΩ maximum.

Hioki 9661-01 CCT-500A Clamp-on Sensors 500A, 500mVac OutputHIO,9661-01 CCT-500A AU500A rated, 500mVac fs output, jaw 46mmØ. Rated input current 500Aac, rated output current 0.5Vac, accuracy (at 45~66Hz). Amplitude ±0.5%rdg, ±0.2%f.s., fs is the 3196 range value, phase ±0.5° or less, frequency characteristics 66Hz to 5 kHz (±1%), max. Allowable input continuous 550 Arms (45~66Hz), max circuit voltage 600Vac rms (insulated wire). Dimensions 77w x 151h x 42dmm, cord 3m. Suitable for Hioki models: 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data logger/scope which takes up to 1.7mVac input.

Hioki 9669-CCT-1000A Clamp-on Sensors 1000A, 500mV AC outputHIO,9669-CCT-1000A AUJaw 55mmØ, 80mmx20mm busbar. Rated input current 1000Aac, rated output current 0.5Vac, accuracy (at 45~66Hz) amplitude ±1% rdg, ±0.01% fs, fs is the 3196 range value, phase ±1° or less, frequency characteristics 66Hz~5kHz (±1%), max. Allowable input continuous 1000A rms (45~66Hz), max circuit voltage 600Vac rms (insulated wire). Dimensions 99.5w x 188h x 42d mm, cord 3m. Suitable for Hioki models 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data logger/scope which takes up to 1.7mVac input.

Hioki Flexible Clamp-on Sensors 10Hz~20kHz, 500/5000AHIO,9667-FCT-5000A AU10Hz~20kHz, 500/5000A rated, 500mVac fs output, jaw 254mmØ max. Rated input current 500Aac, 5000Aac, rated output current 0.5 Vac, accuracy (at 45~66 Hz). Amplitude ±2% rdg ±1.2mV, fs is the 3196 range value. Phase ±1° or less. Frequency characteristics 10Hz~20kHz max. Allowable input continuous 10000Arms (45~66 Hz) max. Circuit voltage 1000Vac rms (insulated wire). Dimensions 254w x 86h x 30dmm. Sensor length 910mm. Suitable for Hioki models: 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data logger/scope which takes up to 1.7mVac input.

Programma EGIL Circuit Breaker AnalyserPRO,EGIL-CB ANALYZER AUOne main contact per phase. Three time channels are connected together on one side. Events at parallel contacts equipped with pre-insertion resistors are recorded and displayed simultaneously. Two separate time channels for measurement of auxiliary contacts. On-site hookup comes with ready-made multi-cable sets for both main and auxiliary contacts. Coil currents are measured automatically, presented together with other readings immediately after testing on the display window or via the built-in printer. A built-in sequencer (program unit) sets the instrument automatically for the next sequential breaker operation. Intended primarily for measuring travel (motion). Can be equipped with an optional serial interface (RS232C) for communication with a PC and the CABA Win Breaker Analysis Software.

Universal Technic Clamp-On AC/DC Current Probe 4000/7500AUNI,P75-3C HYBRID-DP AURanges 7,500A/1.5V & 4,000A/2V with hybrid power fitted for battery and external power supply, 3V operation. Safety sockets 4mm. Clamp is suitable for use with any instrument with an input range of 2Vac or dc, and an input impedance greater than 10kΩ. e.g. voltmeter, chart recorders, oscilloscopes, and power quality analysers.

Page 3: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

Call nowAustralia 800 63 65 - New Zealand 0800 83 473 - Malaysia 603 563 35

Test & Measurement

CHK,CR200 Clamp-on CT 200A~200mA, 2.2Ω Burden Class ICHK,CR200 AUCT 200A~200mA, 2.2W Burden Class I, IEC 185-1987. Suitable for any of the CHK Powermonic Power Quality Analyser like CHK,PM20, PM30 and PM30 Plus units. Suitable for power cables size diameter up to 50mm.

LEM Current Probe 10A~1A for LEM,TOPAS 1000 PQALEM,CURRENT PROBE10A AUCurrent Probe 10A~1A suitable for LEM Topas 1000 power quality analyser.

Hioki 3290 Clamp-On ac/dc HiTester with 20, 200 & 2000A RangesHIO,3290CLAMPONAC/DC AUCurrent Measurement at dc and from 1Hz ac~1000Hz. Current Clamp Hioki 9693 Clamp-on ac/dc sensor 2000A jaw opening 55mm (2.17”).

CHK,CR100s Clamp-On CT 100ACHK,CR100S AUSuitable for CHK power quality analysers like CHK PM20, PM30, PM30 Plus and PM40.

PowerMonic Power Quality AnalysersDesigned and Manufactured for Australia

Try our PowerView Demo analysis software athttp://www.gridsense.net/bin/gsn-pvdemo-35.exe

WEATHERPROOF & RUGGED PORTABLE & FIXED INSTALLATIONS REMOTE DATA COMMUNICATION EASY TO USE POWERFUL SOFTWARE

For more information please contactCHK GRIDSENSE PTY LTDTel: +61 (0)2 8878 7700 Email: [email protected]: +61 (0)2 8878 7788 Website: www.gridsense.net

Tables & graphs of 3 phase V, A, pf, dpf, kW, kVA, kVAr, THD, HarmonicPhase Angle, Individual harmonics up to 48th, frequency, total energy & tariffs

Motor starts-high speed RMSdisturbance capture

Transients-high speed Waveformdisturbance capture

Page 4: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

3

Test & Measurement

Visit our website - www.trcorporation.com

Hioki 9670 Thermal Printing Method Printer, Input RS232CHIO,9670 Printer AUUses stationary type, thermal printing method printer which prints date input via RS232C from a computer or the other host system. Convenient battery that makes easy to carry around. Provides high-speed printing with very little noise. Provides clear printing of 16 x 16 dots and 24 x 24 dots (as well as Japanese characters JIS Level I and II), and can print bar codes. Provides various settings such as enlarged-character printing. Graphics can be printed using bit images.

CATU C-8-36 Phasing Stick-Two pole Phase comparator for Indoor UseCAT,CL-8-36 PH STICK AUDetect differences in voltage between any 2 points of an installation indicated by LED’s. Enables assessment of the residual voltage induced by nearby live lines or circuits, and differentiates it from the one provided directly from a high voltage source. Features, range of voltages 2kV~36kV, high luminosity, compact 0.62m with probes dismounted, high dielectric quality insulating material, 2 x 1.25m elements with removable probes, connected via a high-insulation lead, max use distance 2.25m (with probe extenders), operation testing with a checking device.

Multimeters & ElectrometersFluke 87-2 Digital Insulation MultimeterFLU,87-2 MYA combined digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.

Fluke MultiMeter with BacklightFLU,177 AUGeneral purpose multimeter. True RMS voltage and current measurements, digital display with analog bargraph and backlight, manual and automatic ranging, display Hold and Auto Hold, frequency and capacitance measurements. Overvoltage category EN61010-1 CAT III 1000V/CAT IV 600V.

Fluke Logging MultimeterFLU,189 AUHigher end multimeter. PC interface for data exchange, internal memory allows stand-alone logging of up to 1000 measurements. Extremely fast readings true RMS AC + DC measurements, 100kHz ac bandwidth for voltage and current, dual display with bargraph and two-level backlight, min/max/average with real time clock and 250µs Fast Min-Max, Temperature measurement -200ºC~1350ºC, dBV/dBm with selectable reference. Overvoltage category EN 61010-1 (IEC 1010-1) CAT III 1000V/CAT IV 600V.

Hioki 3805 Multi Function Handy Type Digital MultimeterHIO,3805 AU9999 count display full scale for voltage range. Optional RS232C package for transferring data to a PC, True rms rectified, easy harmonic distortion check function, simultaneous 2-point temperature measurement, maximum, minimum, average value display, 4~20mA measurement value convert to 0-100 % display, for maintaining and serving industrial meter. Meets CAT III 600V requirements and CAT II 1kV requirements.

Page 5: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

4Call nowAustralia 800 63 65 - New Zealand 0800 83 473 - Malaysia 603 563 35

Test & Measurement

Function GeneratorsTektronix 3022/25MHz Arbitrary Function GeneratorTEK,AFG3022 AUDual channel function/arbitrary waveform generator. Frequency range1mHz ~25MHz sine, 12.5MHz square & pulse waveforms, 250 kHz triangle, ramp, noise & DC waveforms. Arbitrary waveform generation 12.5MHz. Gaussian noise to 25MHz. Output into 50Ω 10mV~10V P-P. AM, FM, FSK, and burst modulation. HPIB, USB, & LAN interfaces used with included software allows waveforms to be created on PC and imported into unit. Full screen display also allows display and editing of waveforms on unit itself.

Tektronix 3102/100MHz Arbitrary Function GeneratorTEK,AFG3102 AUDual channel function/arbitrary waveform generator. Frequency range 1mHz~100MHz sine, 12.5MHz square and pulse waveforms, and 250kHz triangle, ramp, noise, and DC waveforms. 12.5MHz Arbitrary waveform generation. Gaussian noise to 25MHz. Output into 50ohms 10mV~10V P-P. AM, FM, FSK, and burst modulation. HPIB, USB, and LAN interfaces used with included software allows waveforms to be created on PC and imported into unit. Full screen display also allows display and editing of waveforms onunititself.

Electrical CalibratorsGenrad 1433-20 Decade ResistorGR,1433-20 MYResistance range from 1mΩ~111MΩ. High accuracy 0.01% up to 10MΩ steps. Low temperature coefficient, 5 ppm/°C. Good frequency characteristics, excellent stability (10ppm/yr, 25ppm/3yrs), low zero resistance (<1 mO per decade). May be used for RTD simulation. Rack mount option.

Logic/Analysers/TestersAgilent/HP 1652B 80 Channel Logic AnalyserHP,1652B AU80 channels, maximum conventional timing rate 100 MHz, transitional timing rate 100MHz & glitch timing rate 50MHz. Memory depth/channel-normal 1KB. Channel to channel delay 4ns. Minimum recognizable glitch width 5ns. Setup/hold time 10ns. 2 scope channels. Bandwidth 100MHz. Simultaneous maximum sampling rate/Ch - 400 MSa/s. HPIB,RS232C. FDD.

Frequency Response AnalysersHP35670A 100kHz Spectrum AnalyserHP,35670A AUQuad channel 100 khz spectrum analyser. Up to 1600 line resolution. Displays frequency response, power spectrum, linear spectrum, coherence, cross spectrum, power spectral density, and time. Signal sources: Fixed & Swept sine, Arbitrary Waveform, Random noise, Chirp. Built-in disk drive. HPIB plotter interface. Bandwidth is 102.4, 51.2 and 25.6KHz for single, dual and quad channel measurements respectively.

RF & MicrowaveRF Signal GeneratorsAgilent/HP E4432B ESG-D3000A 3GHz RF Digital Signal GeneratorHP,ESG-D3000A MYRF signal generator with digital modulation facilities. Frequency range 250Hz~3GHz, resolution 0.01Hz. AM, FM, phase, and pulse modulation. Wideband AM modulation. DC~10 MHz. Internal modulation and pulse generator to 50kHz. Step sweep of frequency and power. Included option UN3 provides DECT, GSM, NADC, PDC, PHS, and TETRA standards. External analogue I and Q modulation inputs. Option 1E5 high stability reference 0.1 ppm/yr included.

Page 6: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual
Page 7: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

6Call nowAustralia 800 63 65 - New Zealand 0800 83 473 - Malaysia 603 563 35

Test & Measurement

Spectrum Analysers - High FrequencyAirmagnet Spectrum AnalyserAIR,AIRMAG SPEC AN AULaptop base spectrum analyser. Specifically identify sources of interference in all Wi-Fi bands 2.4~2.5GHz and 4.9~5.9GHz, and track them to their physical source. Automatic and real time identification of Bluetooth, cordless phones, microwaves, analog video cameras, RF jammers and more. Immediately “see” and name each device.

Rohde & Schwarz FSH3 Spectrum Analyser/Tracking Generator /Vector MeasurementsRS,FSH3-TG-V AUHandheld portable battery operated spectrum analyser 100kHz~3GHz. Resolution bandwidth 1kHz~1MHz. Less than -105dBm noise level(-114dBm typical). Colour liquid crystal display. Suitable for RF surveying applications. Includes Vector Transmission and Reflection Measurements option, tracking generator, VSWR bridge and distance to fault (DTF) options making it suitable for antenna and cable testing. 4h of continuous operation on battery power. Comes with cable for data transfer to PC.

Network Analysers/Antenna & Cable TestAnritsu Cable & Antenna Analyser 25M~4GHz incl RF Power MonitorANR,S331D-5 AUAntenna and cable test set. Frequency range 25M~4GHz, includes power monitor, capability 1M~3GHz, -50~20dBm. Measures return loss, SWR, cable loss, and distance to fault. Integral synthesized signal generator. Return loss range 0~60dB. SWR range 1~65. Distance to fault range 1197m. Insertion loss range -120~100dB. Cable loss range (one port) 0~30dB. Type N(f) port. RS232 interface for printer or PC. Analysis software discs included containing distance to fault and Smith chart tools. Complete with combination precision open/short/load , ac/dc adaptor, and 12Vdc car cigarette lighter adaptor. Battery operated with colour display.

Emerson Process Management 375 Field Communicator EME,375 MY Will configure, test, and diagnose your HART® and Foundation Fieldbus devices. Able to communicate with any device, by any manufacturer. Intrinsically safe. Easy upgrade over the Internet. Interfaces with AMS PC Suite Software.

EMC Test EquipmentSchaffner Modula-6100 Immunity Test SystemSFN,MODULA 6100 AUMultifunction generator to simulate electro-magnetic field interference effects for immunity testing in conformity with international, national and in house standards including the new IEC/EN standards. Generates Interference pulses such as burst and surge and power quality simulations.

Schaffner Automated Step TransformerSFN,INA-6502 AUIntegrated function unit to Modula system. Power line dips to 0%, 40%, 70% and 80%. Complies with EN/IEC 61000-4-11. Includes EUT power control switch.

Page 8: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

7

Test & Measurement

Visit our website - www.trcorporation.com

Power Meters - RFHP 8508A Vector VoltmeterHP,8508A AUNarrowband measuring technique gives a range of over 90dB and a sensitivity of 10µV to trace the smallest signal. Measures the phase difference between its two input channels with at least 0.1º resolution over a full 180°~-180° range, so they can be used for another complete set of measurements such as electrical length, phase distortion, or impedance. 100kHz~1GHz with high impedance inputs. 300kHz~2GHz with 50Ω inputs. Circuit probing to facilitate the design process. Easy programming for ATS’s. Narrowband measurement capability for high sensitivity applications.

Agilent Power Sensor 1nW~100mW, 10MHz~18GHzHP,E9300A AUPower sensor for HP EPM series power meters. E-series average power sensor. 10MHz~18GHz, 1nW~100mW (-60dBm~+20dBm).

Agilent Power Sensor 1µW~25W, 10MHZ~8GHzHP,E9300B AUPower sensor for HP EPM series power meters. E-series average power sensor. 10MHz~18 GHz, 1µW~25W (-30dBm~+44dBm).

HP 8485D Power Sensor 100pW~10uW, 50MHz~26.5GHzHP,8485D AUPower Sensor 100pW to 10uW, 50MHz to 26.5GHz.

Rohde & Schwarz Power Sensor for RS,FSH 10M~8GHzRS,FSH-Z1 AUPower sensor for RS,FSH 10M~8GHz.

RF AttenuatorsWeinschel 82-30-34, 30dB 1000W 3GHz Coaxial AttenuatorWEI,82-30-34 AU30dB 1000W 3GHz Coaxial Attenuator. DC to 3GHz.

Agilent/HP 8494/5B Attenuator Set 81dB x 1dBHP,8494/5B MYCoaxial step attenuator. DC: 18GHz. 0~11dB in 1dB steps. 11~81dB in 10dB steps. Type N(f) connectors. Comprises a connected set of types 8494B and 8495B.

TV Test EquipmentRohde & Schwarz EFA TV Test Receiver 43RS,EFA43 AUDVB-T test receiver, fully compatible with the ETS300 744 standard, receives, demodulates, decodes and analyzes OFDM (orthogonal frequency division multiplex) signals. All key parameters for demodulating the receive signal can be selected automatically or manually. Features, 7MHz SAW filter. 6MHz, 7MHz or 8MHz operating bandwidth. 2K or 8K OFDM modulation. QPSK, 16QAM or 64QAM constellation diagram. 1/2, 2/3, 3/4, 5/6 or 7/8 code rate. 1/4, 1/8, 1/16 or 1/32 guard interval. Hierarchical demodulation. Reed-Solomon error correction 204/188.

Promax TV Explorer Prodig-5PRO,PRODIG-5 AUFor the installation, maintenance and surveillance of terrestrial, satellite and cable TV systems. Automatically provides information about the channels available in the network and their quality. Displays analogue and digital channel picture. Includes a high resolution spectrum analyser function and MPEG decoding. Foxtel approved.

Page 9: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

8Call nowAustralia 800 63 65 - New Zealand 0800 83 473 - Malaysia 603 563 35

Test & Measurement

LAN Analysers/ManagementFluke Networks Etherscope Gigabit W-LAN AnalyserFLU,ETHERSCOPE-WLAN AUEtherscope extended kit full duplex 10/100/gigabit LAN & WLAN 802.11a/b/g analyser. Handheld analyser for discovery of network elements and fault location. Discovers devices by IP subnets, NetBIOS domains, and IPX networks. VLAN discovery shows interface status, connected host details, and trending data. Allows measurement of device details and statistics. Complete with cable ID accessory for tracking cable routes.

Data, Network & TelecommunicationsTelecommunicationsNettest Lite 3000E Signalling Analyser for Telecommunications SystemsGNE,L3000E-ND AUSimultaneous monitoring in both directions of 2Mbps PCM lines. Testing of framed Nx64 Kpbs and unframed 2Mbps PCM systems. Remote operation with MS Windows. Frame Relay installation testing, trouble shooting & decode. All-layer protocol analysis and decode options for ISDN. ISDN Call Emulation option provides the necessary functionality for testing ISDN connections, can setup and receive ISDN calls with user-specified parameters.

See more,fix more.

Fluke Australia Pty Ltd. Phone: (02) 8850 3333 Fax: (02) 8850 3300 Email: [email protected] www.fluke.com.au

©2006 Fluke Corporation. All rights reserved.

Get a better view of your waveforms. Reveal more signal detail. See dynamic signals instantaneously. All with the Color ScopeMeter handheld oscilloscope.The Color ScopeMeter 196C and 199C extend the 190 Series with:• Large high-resolution color screen.• Fast display update rate... and offers all the same high performance scope features.• Up to 200 MHz with 2.5 GS/s real time sampling.• 4 hours battery operating time.• Automatic capture and replay of 100 screens• TrendPlot paperless chart recorder for trend analysis up to 22 days With the Color ScopeMeter 190C Series, you will see more signal detail, helping you do what you do best— fix things!

Try it out on-line at www.fluke.com/190

The Color ScopeMeter® 190C Series:Get the best view of problem-solving in the field

Page 10: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

Test & Measurement

Visit our website - www.trcorporation.com

Fluke Nettool LAN AnalyserFLU,NETTOOL AUVoIP monitoring. Bi-directional LAN test tool. Diagnose VoIP phone boot-up problems, call control and measure key call quality metrics. Compatible with IP phones employing either SIP or SCCP call control protocols. VoIP Log displays call control events, QoS configuration, and call quality metrics. Boot Log displays key boot events such as DHCP address acquisition, DNS lookup of call servers and gateways, downloading of operating files, and call server registration. Inline testing of LANs at the workstation level. Tool is plugged in-line between workstation and LAN. Provides indications of NIC and hub functionality, cable connectivity, and protocol compatibility between LAN and workstation. Use as a first line fault finding tool for IT departments.

LAN Cable TesterFluke DSP4300 Category 5/5E/6 Cable Certification ToolFLU,DSP4300 MYCategory 5, 5E and 6 cable tester and certification tool. This cable tester includes PC link and analysis software. Category 5, 5E & 6 permanent link heads included. These units include internal memory and memory card options. Testing to TSB-95 standard also supported for Category 5, 5E.

Fibre OpticsFiber Video Display ScopeFLU,FT330 AUHandheld battery operated video scope for fiber inspection.

Fiber Inspection Video Probe X 250 MagnificationFLU,FT350 AUConnects to a FLU,OPTIFIBER or FLU,FT330 to let you inspect the ends of fiber optic connectors. 250 X magnification reveals dirt, scratches, and other defects that can cause poor performance or failures in fiber optic networks.

Fiber Inspection Video Probe X 250 & 400 Magnification FLU,FT650 AUFibre probe for use with Fluke Optifiber OTDR or FLU,FT330 handheld video scope. Has switchable 250 and 400 times magnification.

Fitel S325A Precision Fibre CleaverFIT,S325A AUCan be used with precision splicers for single and multi mode fibres. Features a built in sharps collection bin which automatically stores fibre offcuts as each fibre is cleaved.

Page 11: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

0Call nowAustralia 800 63 65 - New Zealand 0800 83 473 - Malaysia 603 563 35

Test & Measurement

Fitel S177A Core Alignment Fusion SplicerFIT,S177A AUPrecision core alignment single and multi mode fusion splicer. Fully automatic and provides a typical splice loss of 0.02dB on single mode fibre, and 0.01dB on multi mode fibre. Splice time is typically 9 seconds. Temperature operates from -10~50ºC, humidity operates up to 90% at 38ºC, and altitude sensors operate up to 4000m which adjust arc time and intensity as required. Also includes a built in heater for applying splice protectors and a splice tension tester (200g). Front mounted colour display and can be operated from ac (100/120V 200/240V), or battery (up to 70 splices). Does not include cleaver which must be rented separately.

Nettest CMA 5000 Singlemode 43/45dB OTDRGNE,CMA5000SM-45 AUSingle mode OTDR with SC/APC (angled) adaptor. 1310/1550/1625 dynamic range 43/45/43dB. +20dBm meter and light source, and VFL (Visual Fault Locator). OTDR has built in CD-R/W and 20GB hard drive. Dedicated touch screenandhardkeyuserinterfaces.Mainsandbatteryoperation,batterylife >3h. 10/100MB Ethernet port for network connectivity. USB ports.

Cable/Pipe Testers & LocatorsCScope CATXDSGV-KIT Cable and Pipe LocatorCSC,CATXDSGV-KIT AU/NZCable location tool. Includes 33kHz generator with touch button controls and LCD, XD receiver/ locator with 33kHz, power or radio modes. Direct connection cable, stake and 75mm tong set. The transmitter can operate with direct connection, tongs or induction. The instrument will also determine cable depth, range 0.2m to 3m . It will operate with the Radiodetection 33kHz sondes.

Power AnalysisInsulation/Condition/Resistance TesterMegger DLRO-10X Digital Low Resistance OhmmeterMEG,DLRO-10X AU/NZ/MYAutomatically selects the test current, (up to 10Adc) to measure resistance from 0.1µΩ~2kΩ on 1 of 7 ranges. Real-time download of results and on-board storage for later download to a PC. Automatically detects continuity in potential and current connections. Warning of high voltages at the terminals. Warning of current flowing in test sample. Many operating modes including fully automatic. Alpha-numeric keypad for entering test notes. Selectable high and low limits. Autoranging with manual option.

Megger Digital Earth Test Clamp MEG,DET20C AUMeasures ground resistance from 25mΩ~1550Ω . Measures ground leakage current from 0.2mA~35A. Automatic self calibration. Auto ranging. High and low alarms. Large memory. Download to Megger Download Manager. Measures earth resistance in installations such as buildings,pylons and RF transmitter sites. Use for the inspection and verification of lightning protection systems. Large jaw opening.

Megger MIT1020 Diagnostic 10kV Insulation Resistance TesterMEG,MIT1020-10KV DIT AUBacklit display, variable test voltage from 50~5000V, Automatic IR, PI, DAR, SV and DD tests, measures to 35TΩ, RS232 & USB download of results. IEEE 43-2000 recommends the use of 10kV for motor windings rated above 12kV. Protection rating of IP54. Mains or battery powered.

Page 12: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

Test & Measurement

Visit our website - www.trcorporation.com

Power Analysers & RecordersHioki 3197 Power Quality Analyser with 3x1000A Clamp-on CTsHIO,3197PQA AUMonitors inrush current, voltage swell, voltage dips, transient over-voltage and interruptions. Measure and records power and power factor, active/reactive energy, demand, load changes (with graph display), voltage and current. Measures impulsive voltage quality. RMS voltage quality, voltage swell, voltage dips & voltage interruption. Power quality, frequency, voltage, current, current peak, active/reactive/apparent power & power factor (displaced power factor). Three phase quality, voltage unbalance ratio, current unbalance ratio, harmonic quality (up to 50th order). Harmonic, voltage, current, ower, voltage/current phase angle. Total harmonic, voltage distortion, current distortion (THD-F, THD-R).

Hioki 3169-20 Clamp-On Power HiTester for Power MeasurementsHIO,3169-20CLAMPONPT AUAllows measurement of 1ph~3ph 4-wire circuits with a single unit. In addition to measuring standard parameters such as voltage, current, power, power factor, and integrated values, this unit can simultaneously perform demand measurements required for carrying out power management and energy-saving measures, as well as harmonic measurements. Features PC card data storage and comes equipped with an RS232C interface for PC communications. Can measure the power of just a few cycles, enabling more detailed and effective energy-saving measures. Supplied with Hioki 9625 power measurement support software for data analysis. Measure up to 3ph, 3 wire system (displays voltage and current for 3 lines), up to 4 x 1ph, 2 wire systems, 5A~5kA range, PC card data storage, power recording for individual waveforms. Simultaneous recording of demand values and harmonics. Applications are energy maintenance/control, energy control under ISO 14000, saving energy activities, power consumption measurement of specific device/equipment, harmonic analysis.

Page 13: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

Call nowAustralia 800 63 65 - New Zealand 0800 83 473 - Malaysia 603 563 35

Test & Measurement

Hioki Remote Power Measurement System 2331-20 RPMS SmartSite HIO,2331-20RPMS AUFor multi-channel power recording 1ph 2 wire up to 6 circuits or 1ph 3 wire & 3ph 3 wire up to 3 circuits. Provides via a PC, management of measurement data to support energy and environmental management. Modulated measurement units take advantage of a variety of infrastructure to collect measurement data. Use as a stand alone logger and for remote monitoring. Use as a PC measurement logger keeps measuring and continuously saves the data. Measurement modules comes with memory and clock. Build a customised and remote measuring system by utilizing existing data network. Modules for temperature, humidity, instrumentation and pulse, power module for multiple circuits. Large internal memory. Communication module with built-in real-time clock tracks the data of each measurement module to the second. Air Module for constructing SS wireless systems.

Hioki Remote Power Measurement System 2332-20 RPMS SmartSiteHIO,2332-20RPMS AUDescription as for HIO,2331-20RPMS above.HV Diagnostics 30kV-15mA DC/VLF High Voltage Insulation DielectricsTest Set HVD,HVA30-DC/VLF AUVLF (0.1Hz), DC (±), cable fault conditioning (Burning), and sheath/jacket testing modes all included. 0.1Hz & 0.02Hz. For solid dielectric cables such as XLPE and EPR. Fully automatic or manual cable test sequences complying with International Standards/Guides such as IEEE 400.2, VDE 0296, CENELEC, etc. True symmetrical sinusoidal, load independent, output waveform across the full load range. Real-time display of actual output waveform. Easy to use, menu guided, large backlit user interface. Large output load capability (up to 5µF). Automatic and integrated load capacitance measurement with optimum frequency selection. Storage of test results for later retrieval or download to laptop. Short circuited protected.

HV Diagnostics 60kV-50mA DC/VLF High Voltage Insulation Dielectrics Test SetHVD,HVA60-DC/VLF AUTrue sine wave low frequency output. 0.1Hz & 0.02HZ. For VLF, DC and jacket/sheath testing. Fault conditioning capability. Test result storage capability. Short circuit protection. Complies with CENELEC, IEEE 400.2, VDE 0296 and other international standards. Manual or fully automatic test sequence selection. Real-time display of actual output waveform. High voltage power source suitable for testing electrical plant including cables: XLPE, PE, EPR, PILC etc, capacitors, switchgear, transformers, rotating machines, insulators and bushings.

Electrical TestersKyoritsu Phase Sequence Meter 110~600 Volts 50/60HzKYO,PSM8031 AUKYO,8031 MYPhaseindicatorwithopenphasecheckerandphaseindicatordesignedtocheckthe presence of open phase and also the phase sequence by rotating disk and lamps. Check a wide range of 3ph power source from 110~600V. Operational voltage 110~600Vac, time limit for continuous >500V within 5min. Frequency response 40~200Hz (ac 110~200V), 40~400Hz (ac 200~600V) safety standard IEC61010-1 CAT.III 600V pollution degree 2 withstand voltage 2.2kVac for 5s. Dimensions 106L×75W×40Dmm, weight 350g approx. Cord 1.5m (R: red S: white T: blue)

Page 14: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

HVA 30 33KVAC VLF & 30KV DC HIGH VOLTAGE TEST SET

DFB35 TAN DELTA DISSIPATION DIAGNOSTIC INSTRUMENT

www.maceyselectrical.com

VLF (33kV AC)DC (30kV DC)Jacket/SheathFault Conditioning

All-in-One Unit!!!

HVA30 FEATURES• Include 1 x Set of Test Leads/Hook–up Cables 4.5m• Include IBM Compatible PC Software• 0-33KV VLF AC and 0.02 to 10Hz Output• 0-33KV DC ( Both Polarities ) Output• Programmable Fully Automatic Test Sequences• RMS Digital Metering of Voltage & Current• Automatic Measurement of Resistance and Capacitance • Oscilloscope Function and Flashover Detection• Frequency Optimizer and Controlled Arc Regulation• Fast Trip Out and Condition Burn Modes• Storage of Test Results & RS232 Download• Load Independent, Symmetrical Sinusoidal Output• Include Shipping/Transport Case

Less than 20kgLess than 20kgAPPLICATIONS INCLUDE…

• Cables: XLPE, PE, EPR, PILC etc.• Capacitors • Switchgear • Transformers• Rotating Machines (IEEE 433)• Insulators • Bushings

When the HVA30 is usedas a voltage source for theDFB35 the HVA30 pureSinewave allows veryaccurate measurements oflow TAN DELTA levels ofXLPE Cables.

DFB35

Page 15: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

4Call nowAustralia 800 63 65 - New Zealand 0800 83 473 - Malaysia 603 563 35

Test & Measurement

Hioki 3455 High Voltage Insulation TesterHIO,3455HVIT-5KV AU/MYPI (Polarisation index) and DAR (Dielectric Absorption Ratio) function to check insulation quality and step voltage test to detect for signs of deterioration. Generates a wide range of test voltages, from 250V to 5kV. The voltage may be chosen from the commonly used presets of 250V, 500V, 1kV, 2.5kV & 5kV, or set to desired level by increments or decrements of 25V or 100V. Insulation diagnoses for automatic calculation and indication of PI and DAR, step voltage testing and temperature correction. Large memory stores up to 100 manual records and a logging function for 10 data (360 times). Stored data may be displayed on the LCD or down-loaded to a PC. The date and time of measurement also recorded.

Megger RCDT330 Residual Current Device TesterMEG,RCDT330 AUTests standard, dc, selection and programmable RCDs. Ramp testing. Auto (remote) testing. 3ph safe. Enables testing on 110V centre tapped supplied. Performs 1/21, 1xI & 50xI tests on RCDs rated at 10mA, 30mA, 100mA, 300mA, 500mA & 1000mA on general and selective (time delayed) RCDs. Tough rubber armoured case with built-in cover. Weatherproof to IP54. USB interfacefordownloadingtestresult.

Current InjectorsT&R PCU1-SP with CT Ratio/Polarity and NLU5000A Loading UnitT&R,PCU1-SP NLU5000A AUMedium powered primary current injection system. Features 5kA maximum output current (higher overload current for 2s). Multi-function digital timing system. Digital true RMS memory ammeter. Solid state switching. 2000A and 5000A load units. Three range outputs on loading units. Rugged, compact design. Optional trolley mounting of system. Secondary injection up to 100A. Direct reading CT ratio and polarity. May be configured to either give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V range or 1250A on the 9.2V range.

Power Line Conditioner/UPSPowerware 700VA/420W Line Active UPSPOW,700VAUPS AUProtection in the 700~3000Va range. Input Voltage Range: 120/140/160-276 Vac. Frequency 45~65 Hz. Plug and play tower, under monitor, or 2U rackmount. Line-interactive.

Data Acquisition & RecordingData LoggersHioki 3632-20 Temperature Logger with Internal Sensor OnlyHIO,3632-20 AUTemperature logger (1 channel) includes 1 x RS232C & 1 x USB communication base, utility software, RS232C and USB interface cables. Temperature range -20~+70ºC. Accuracy -20~-0.1ºC +/-1.0ºC. 0~35ºC +/-0.5ºC, 35.1~70ºC +/-1.0ºC. Internal thermistor sensor, water resilience IP67. Built in LCD.

High Speed Waveform Recorder

Hioki 8860 8 Channel High Speed Memory RecorderHIO,8860 AUHigh speed memory recorder, 20MS/s sampling rate, 8 analog channels, 16 logic channels, built in printer. 512MW or direct access memory, 60GB hard drive built-in, PC card type II slot up to 4GB ATA flash card (optional) USB, LAN interface and large colour screen.

Hioki 9725 Memory Viewer SoftwareHIO,9725 AUData processing software for Hioki 8860 High Speed Memory Recorder. Functions: file loading, maximum loadable data size 2GW file saving, measurement of data binary, partial saving between A/B cursors is possible. Screen images BMP and PNG, calculation results. Display of saved binary files, displayable channels per sheet analog 32, logic 16 channels. Displayablesheets16.

Page 16: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

5

Test & Measurement

Visit our website - www.trcorporation.com

Hioki 8938 FFT Input Signal ModuleHIO,8938 AUFFT Module with anti-aliasing filter. Frequency range dc to 400kHz, sampling rate 1MS/s. Maximum input voltage 400Vdc, 240Vrms.

Cambridge Frequency Transducer 45~55Hz 240VacCT,891040-240 AUFrequency transducer from 45~55Hz with analogue output 0~10VDC. Powered from 240Vac only.

Cambridge Frequency Transducers 891040 55~65Hz 110VacCT,891040-110 AUFrequency transducer for frequency from 55~65Hz with analogue voltage output 0~10Vdc. Powered from 110Vac only.

Physical MeasurementPressure & Humidity TransducersDruck PTX1400-25 25Bar Pressure Transducer 4-20mADRU,PTX1400-25 AUPressure transducer, 4~20mA output, 0~25bar (360psi) input. Requires 9~28Vdc. Supplied with 12V, 500mA power pack.

Visual Inspection Equipment & EndoscopesWohler VIS 220 Visual Inspection System for Pipes and DrainsWOH,VIS220Compact colour video pipeline inspection system, 26mm colour camera with bright white LED’s on 19.5m of flexible push rod with metric marking. Camera sensitivity 3 Lux, lens f=2.5mm, F=2.0, view angle 120º, waterproof to 30m water depth. Suitable for insertion in pipes and spaces from 40 to 150mm diameter. The system is supplied with 2 battery packs and an AC charger/power pack, each battery pack lasts approx 1.5h. Supplied with 5.6” TFT display with extension cable, video output suitable for video recorder (notsupplied).

Silverado PF136 Portable FibrescopeSIL,PF136 AUPortable fibrescope, 9mm diameter, 1320mm working length, gooseneck semi rigid insertion tube, supplied with 90º side view adaptor mirror. Built in battery compartment for LED light source. Viewing direction 0°, viewing angle 45º, Depth of view 30mm to 150mm. Side view adaptor viewing direction 90º, viewing angle 45º, depth of view 30mm to 150mm, tip diameter 10mm.

Tachometers/StrobescopesMonarch Palmstrobe Compact Size Portable StroboscopeMON,PALMSTROBE AUCompact size portable stroboscope, flash rate from 100~12,500FPM, 6 digit alphanumeric backlit LCD. Tachometer range 5~250,000RPM (only with external sensor connected, not included). External sensor input TTL only. Supplied with 2 x removeable rechargeable battery packs, charger andtransitcase.

Page 17: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

6Call nowAustralia 800 63 65 - New Zealand 0800 83 473 - Malaysia 603 563 35

Test & Measurement

Monarch PLT200-KIT Digital Contact/Non Contact TachoMON,PLT200-KIT AUHand held digital contact/non contact tacho kit. Ranges optical/non contact 5~200,000 RPM, contact 0.5~20,000 RPM. Display 5 digits, 5 alpha numeric LCD. Non contact operating range 90cm, tripod mounting. Direct contact tips and contact wheel supplied. Programmable for IPM, FT/M, YPM, cm/M, m/M, RPM, RPS, RPH and Totaliser up to 200,000. Output TTL pulse.

Scales & BalancesAND Mercury Platform Weighbeams for Pallet up to 2000kgAND,WEIGH-BEAMS AUFor pallet weighing. Total weight capacity 2000kg for the two weigh beams. Two stainless steel weigh beams supplied, length 1200mm, width 100mm, height approximate 80mm, weight of each beam 13kg. Connection cable length 5 metres. AD4406 display supplied, RS232 output. Transit case with handlesandwheelsforeaseofhandling.

A&D Mercury MX50 Moisture AnalyserAND,MX50 AU Maximum sample weight capacity 51g, resolution 0.001g, moisture content accuracy over 1g 0.1%, over 5g 0.02%. Halogen lamp heater, 400W max. Drying temperature 50~200OC. Measurement programs 20 sets, measurement mode moisture content, wet or dry, dry content, ratio, weight. Heating mode standard, automatic, quick, timer, manual. Display large VFD, interface RS232C, CD-ROM software supplied. Pan sample size diameter 85mm.

Non Destructive TestingPCWI High Voltage Pulse Crest MeterPCW,HV-PULSE CREST AUMeasure and indicate peak voltage.

PCWI 40kV Pulse Porosity (Holiday) DetectorPCW,P40-PULSE AUPulseporosity(Holiday)detector.Detectspinholesincoatingsandwrappingabove 150µm on metal substrates such as pipes and tanks. Can be used on dry or wet surfaces. 0~40kV output, 4 digit LED display of voltage, alarm sensitivity setting between dry and wet. Supplied with rechargeable battery, 10h charger, red probe handle and 2m length of rubber coated cable, 60mm connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension and 80mm probe extension.

Panametrics NDT 37DL-Plus Ultrasonic Thickness GaugePAN,37DL-PLUS AUThickness gauge with large display (A-scan), which will display the returned waveform. It has echo-echo through-paint capability. Supplied with WIN37DL PLUS software and cable. The supplied probe is 11 mm diameter with a 1~500mm operating range and a -20~500OC temperature operating range. The instrument has a MIL-STD-810E hazardous area operation.

Page 18: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

7

Test & Measurement

Visit our website - www.trcorporation.com

General Industrial Equipment Industrial Process CalibratorsDruck DPI610~20~NATA 20Bar Pressure Calibrator NATA CertificationDRU,DPI610-20-NATA AUPneumatic pressure calibrator including pump and current voltage standard. Pressure range -1~20bar ±0.025%fs. Voltage input ±50Vdc, ±0.05%rdg, ±0.004%fs. Current input ±55mA, ±0.05%, rdg ±0.004%fs. Temperature -10~40°C ±1°C (ambient) switch open/closed. Voltage output 10Vdc ±0.1% or 24V ±5%. Current output 0~24mA ±0.05% rdg ±0.01%fs. Data logger stores upto 10,000 values. mA ramp configurable. Pressure port G ⅛f, includes flexible hose kit. Pump includes screw adjustment

Druck DPI610~20IS Pressure CalibratorDRU,DPI610-20IS MYRanges -1~20bar. Accuracy 0.025% fs all ranges. Integral combined pressure/vacuum pump. Dual readout: input & output. 4~20mA loop test: auto step and ramp. RS232 interface and fully documenting version. Remote pressure sensors. Intrinsically safe version.

Druck Loop CalibratorDRU,UPS-3 AUMeasure and source 0~24mA, accuracy 0.01% of reading, dual mA and % readout, linear or flow. Step, span check, valve check, ramp. Measurement and continuity 60Vdc. HART compatible internal 235Ω loop resistor, menu selectable. Large graphic LCD.

Jofra C650 CalibratorJOF,C650 MYA fast, timesaving, and reliable true temperature calibrator designed for on-site use. Produces temperatures between 33~650°C. Display resolution ±0.1°C, accuracy ±0.9°, stability 0.1°C. Well depth 120mm x 28Ømm. Comes with a multi-hole insert of ⅜”,¼”, 3/16” & ⅛”Ø holes. Light weight andportable.

Hart 3125 Surface Probe Calibrator 35~400ºC NATA Certification HAR,3125-NATA AUTemperature range 35~400ºC. Display accuracy ±0.5~200ºC, ±1~400ºC. Stability ±0.2~300ºC, ±0.3~400ºC. Resolution 0.01º. Heating time 25~400ºC 22min. Cooling time 400~100ºC 65min. Temperature surface plate 3.8”Ø accessible.

Hart 7102-NATA Micro Bath -5~125ºC NATA CertificationHAR,7102-NATA AUTemperature range -5~125ºC. Tank 1.9”Ø, 5.5” deep, volume 0.75L, includes tank lid. Accuracy ±0.25ºC, stability ±0.015ºC @ -5ºC, ±0.03ºC @ 121ºC, resolution ±0.01ºC. Heating time 25~100ºC 30min, cooling time 25~0ºC 30min. RS232C interface and CD-ROM software supplied.

Page 19: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

www.ipi-infrared.com

Sales, Training, Service and Expert Advice.

Infrared Thermography Specialists

The IR-InSight®XST (extra sensitivity) is a rugged, video rate, portable infrared camera that delivers AMAZING image quality with precision temperature measurement capability. It's extreme durability enables it to withstand the everyday abuses of the work environment. With "point and shoot" single trigger operation, it's the easiest-to-use infrared camera on the market.

The award winning IR FlexCam® series offers the most advanced, intuitive, easy-to-use, highly sensitive, dependable, fully radiometric solution. And it can be viewed on the big screen!Available in 4 affordable options, FlexCam PRO, FlexCam T, FLexCam S and the new FlexCam R.

World's most sensitive VOX detectorBig 5 inch screenOutstanding Image QualityWindows CE interface, simple to use

Super High Performance Series...

This introductory course gives you hands-on experience with an infrared camera and a practical understanding of how to apply fundamental infrared theory. The course also undertakes the basic principles of analysis and reporting and in-field procedures.

An infrared camera will be provided for you! For bookings and information email: [email protected]

Training Course: Introduction to Infrared

Inspect Electrical Cabinets SAFELY and QUICKLYNO removal of panel coversVery Low CostVariety of Sizes and MaterialsEasy to Install

Industrial Precision Instruments Pty Ltd15/634-644, Mitcham Rd, Mitcham VIC 3132

Ph: 03 9872 5055 Fax: 03 9872 6055

NEW: IR-Insight XST > $20k with VOX detector inside!

NEW: IR-FlexCam Series

NEW: Infrared Inspection Windows

Highest Resolution 320x240 detectorHighest Image QualityHigh Speed Performance

NEW: S160 Super Compact IR CameraFully Radiometric! Auto Heat Seek

Automatic Hot or Cold seeking cursors easily pinpoint problem areas. The light, compact, user friendly design with tilting LCD screen allows you to reach even the most difficult places. It also comes with advanced reporting software to make it the one of most complete professional packages available. Ask about the NEW low cost S120!S160

IR FLEXCAM

Infrared ViewingWindow

HY6000A HY6800 HY6900

IR INSIGHT XST

The S160 is a super compact high performance video rate camera. It is FULLY RADIOMETRIC, which means you can pinpoint any of the 19,200 individual temperature points, and extraordinary accuracy over distance.

Overloaded Circuit Hot Connection Hot Motor Predictive Maintenance

Power Networks Building Mechanical

Page 20: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

Test & Measurement

Visit our website - www.trcorporation.com

Hart 9170-R Metrology Well With Built In Reference & NATA CertificationHAR,9170-R-NATA AUMetrology well calibrator temperature range -45~140ºC with built in reference thermometry. Reference input accepts (not supplied) 100, 25 & 10Ω PRT’s. Display accuracy ±0.1ºC, stability ±0.005ºC full range, resolution 0.001ºC. Well depth 6.3”, insert type A 3/16, 1/8, 1/4, 3/8”. Large LCD, numeric keypad and on screen menus. Heating time 23~140ºC 32min, -45~140ºC 45min. Cooling time 23~-45ºC 44min, 140~23ºC 19min. Supplied with RS232C interface and CD-ROM software.

Hart 9150 Furnance 150~1200°C HAR,9150 AURange 150~1200°C. Stability ±0.5OC, display accuracy ±5°C across entire range. Display resolution 0.1~999.9°C, 1° above 1000°C. Well 1.25”Ø, depth 5.5”, insert type A. 1/16, ¼, ⅜, 3/16, ⅛, ½”. Heating time 0~1200°C 35min, cooling time 140min.

Hart 7103-NATA Micro Bath -30~125ºC NATA CertificationHAR,7103-NATA NZTemperature range -30~125ºC. Tank 2.5”Ø, 5.5” deep, volume 1L, includes tank lid. Accuracy ±0.25ºC, stability ±0.03ºC @ 25ºC, ±0.05ºC @ 125ºC, resolution ±0.01ºC. Heating time 25~100ºC 35min, cooling time 25~-20ºC 45min. RS232C interface and CD-ROM software supplied.

Environment Test Chambers/OvensAngelantoni CH340 Environmental Temperature ChamberACS,CH340 AUEnvironmental Chamber for temperature and humidity. Temperature range -75~180ºC, Humidity range from 10~98% RH in the range of +10~+80ºC, Dew point range +2~+94ºC for continuous tests. Relative Humidity accuracy +/-1% ...+/-3%. Useful capacity 336lt. Internal dimensions: 600Wx800Dx700Hmm. External dimensions 850Wx1725Dx1516Hmm. Control by uPLC and graphical control panel placed on the door. It allows to program temp and RH cycles and to control all chamber functions and alarms. Entry port, door with inspection window, internal lighting, 1 shelf, RS232C interface. Electrical rated power 5.7KW, maximum used power 9KW. Voltage 400+6%, -10%, 50Hz, 3ph. Noise 63dBA , weight 750kg approximately including transit case.

Temperature Meters/IR ThermometersFluke 576 Photo Temp Infrared Thermometer with built in CameraFLU,576 AU/MYInfrared thermometer -30~900ºC with built-in digital camera. Minimum measurement 19mmØ, laser class II, 3 point spot. Includes adjustable emissivity from 0.1~1 by 0.01. Target size 1/60 of distance. Max, min, dif and av displayed on backlit lcd with bar graph. Data output USB or 1mV/ºC, windows software and cable included. Accuracy ±0.75% of reading or ±1ºC which ever is greater. Response time 250ms. Display resolution 0.1ºC. Continuous measure mode. Digital camera and flash built in.

Page 21: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

0Call nowAustralia 800 63 65 - New Zealand 0800 83 473 - Malaysia 603 563 35

Test & Measurement

Fluke 52-2 Digital ThermometerFLU,52-2 MYRelative time clock on MIN, MAX, and AVG provides a time reference events. Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy . Measures J, K, T, & E-types of t/c. Readout in ºC, ºF, or Kelvin (K). Battery life: typical 1000h. Battery door allows easy replacement without breaking the calibration seal. Large backlit dual display shows any combination of T1, T2, T1-T2 plus MIN, MAX, or AVG. Additional t/c type R, S, & N (a total of 7 types). Recall function allows logged data to be reviewed on the display. IR communication port allows data to be exported to optional FlukeView Forms® Temperature PC software for further analysis and graphing. Data Logs up to 500 points of data with user adjustable recording interval.

Testo 845 IR Thermometer With Humidity Probe and T/C ProbeTES,845 AURange -35~950ºC with built in humidity probe, range 0~100%RH. Switchable distance ratio far field 75:1 16mm, distance 1200mm, close focus 1mm, distance 70mm. Laser class II, 4 point spot/cross far field, 2 point/1point close focus. Includes adjustable emissivity from 0.1~1.0, max, min, displayed on backlit LCD . Data output USB windows software and cable included. Accuracy ±0.75% of reading 100~950ºC. Display resolution 0.1ºC. Continuous measure mode. Plug in T/C probe supplied.

Humidity & Moisture MetersGE Panametrics PM880 Industrial Moisture AnalyserPAN,PM880 AUIntrinsically safe moisture analyser for compressed air systems, non-corrosive gases & hydrocarbons such as natural gas (IS certification to ATEX and CSA). Displays dew point, moisture concentration, pressure & temperature. Dew point calibrated measurement range -80~20°C with data to -110°C. Pressure range 7~69bar limited by sensor, gauge and safety-valve (operating range from 5micron Hg). Temperature range -30~70°C. Gas flow operating range from static to 10,000 cm/sec velocity. Supplied with compact sample system with gauge, safety-valve, sampling valves and fittings (1/4 in Swagelok). Data logging of up to 100K moisture points, with infrared port and software for download. Battery powered only (15-24h operation) with second battery and charger (note charger is not IS).

Flow MetersFlow Meters - Liquid & GasClimaAir 3 Flowmeter for Compressed Air and GasesPVL,CLIMA3 AUPortable gas flowmeter for compressed air and other applications. Fitted with “Combisensor” insertion probe for simultaneous measurement of flow, pressure and temperature. Measuring ranges flow (mini-turbine]) 0.06~40m/s (actual), pressure to 15bar, temperature -20~80ºC. Supplied with valve and adaptor-kit for cold-insertion into tapped pipes approx 25~450mm ID. Flow computer functions include flow correction, volume-calculation, and data logging for about 15,000 values. RS232 interface & cable, and software for data download. Rechargeable with AC adaptor.

Page 22: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

Test & Measurement

Visit our website - www.trcorporation.com

Air Conditioning & Air Quality - HVAC & IAQAir Flow Measurement/Air QualityTesto 635-2 Humidity, Temperature & Dewpoint MeterTES,635-2 AUPortable humidity meter fitted with robust stainless probe with sintered filter-cap for general or duct measurements to 120ºC, and fast-action K-type surface temperature probe. Displays relative humidity, absolute humidity, dew point, degree of humidity, enthalpy, temperature, and differential temperature (dewpoint~surface). Operating range 2~98%RH (±2%). Air temperature -20~120ºC (±0.2/0.5). Surface temperature -60~300ºC (±0.1). Internal memory for 10,000 values with USB interface, cable and software for download and presentation. Battery operated.

TSI 8705 DP-CALC Differential Micro-ManometerTSI,8705 AUDifferential micro-manometer measuring differential pressure, velocity, average, volumetric flow, maximum and minimum. With static pressure calculations, density correction and K factor. Pressure range -1245~3735Pa. Velocity range 1.27~78.5m/s. Supplied with 200~980mm telescopic pitot tube. Datalogging (1000 point) with RS232C interface and software. Battery powered.

TSI 8710 DP-CALC Differential Micro-ManometerTSI,8710 AUMicro-manometer for static or differential pressure, velocity, volumetric flow, atmospheric pressure and temperature. With statistical analysis, density correction, K factor and automatic actual/standard flow calculation. Differential pressure range ±3735Pa. Velocity display to 78m/s (range depends on probe). Supplied with static tip, Pitot tube, velocity matrix and temperature probe. Datalogging (1,000 point) with RS232C interface and software. Rechargeable cells or AC adaptor.

.

Testo 445 Vane Anemometer with 16mm vaneTES,445 AUMicro-vane probe. Simultaneous digital display of air velocity and temperature, with continuous-update, max, min & mean functions. Volume-flow option with entry of duct dimensions .Telescope mounted metal probe, vane 16mmØ. Operating range 0.4~60 m/sec, accuracy ±0.2m/s, ±1%mv up to 40m/sec. Temperature range -30~140ºC for short-term measurements. Selectable site-locations, and 3,000 point internal memory for manual saving or automatic data logging. Battery powered.

TSI VelociCalc 100mm Vane Anemometer with Volume DisplayTSI,8324 AUVane Anemometer with 100mm head, supplied with handle & 900mm articulated telescopic extension. Velocity range 0.25~30m/s ±1%; temperature range 0~80ºC ±0.5ºC. Volume display range 0~4.36x106m3/h with input for circular or rectangular duct dimensions. Variable time-constant; sample statistics av, max & min; and “sweep” mode for extended continuous sampling. Internal memory for single point measurements or time-based data logging, up to 2,849 samples and 1,000 test IDs, with serial interface, cable and software for data download. Direct data acquisition [polling] from PC terminal modes. Battery powered with auto-power-off, and optional AC adaptor.

Page 23: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

Call nowAustralia 800 63 65 - New Zealand 0800 83 473 - Malaysia 603 563 35

Test & Measurement

Air Conditioning Balancing InstrumentsTesto 560-2 Electronic Manifold for Refrigeration TestingTES,560-2 AUThree-way valve bank, for commissioning, maintenance and repair of refrigeration systems. Stainless-steel block for use with common pressure media including CFC, FC, N, CO2 and ammonia; with stored data (including saturation properties) on 36 refrigerants. Measurement of vacuum (0~200hPa), pressure (0-50bar), ambient [case] temperature for compensation (-10~50ºC) and system temperature (-100~400ºC instrument range; supplied with pipe-wrap probe 0~120ºC). Calculations for absolute/relative pressure, vacuum drying-efficiency, system cooling/heating capacity, leakage testing, superheating or sub-cooling values. Data storage, or interval-logging up to 100,000 readings, with serial interface and software for download, analysis and documentation. Battery or AC adaptor powered.

Weather StationsEnvirondata WeatherOne Wind Speed & Direction LoggerENV,DL20WSD AU

Coming Soon!Environdata WeatherOne Real Time Readout SystemENV,RD20A AU

Coming Soon!

Occupational Health & SafetyLight & UV MeasurementHioki Lux HiTester Digital Illuminance MeterHIO,3423 AU/MY/NZManual switching and autoranging. LCD display with 3½ digits (“1999”) for five measuring ranges to 20/200/2000lx in 1-count steps, 20,000lx in 10-count steps and 200,000lx in 100-count steps with accuracy ±4%. Response time in autorange mode 5sec (2sec in manual range mode). Autozero, hold andbacklightfunctionwithdelayfortakingreadingsinlowlight.Inputforacpoweradaptor,connecting-cabletoallowseparationofsensorunitandmeter, and 200mVdc analog output with cable. Battery powered.

Noise & Sound AnalysersARL EL-316 Environmental Noise Logger Type 1ARL,EL-316 AUEnvironmental noise logger with display for field-reading of summary results. Portable, self-contained and weatherproof. Type 1 performance, continuous 90dB dynamic range, fast response, frequency weightings A and C. Monitors environmental noise continuously for up to 3 weeks, calculates and stores over 7500 sets of Ln indices. PC required to set up system and download data using software supplied. Set up also possible from front-panel.

Ivie IE-35 Type 1 Audio Analyser with Dell Axim X51V PDAIVI,IE35-2P AUFitted with half-inch free-field Type 1 microphone and pre-amplifier. Functions include SPL (sound level), real-time analysis, seat-to-seat variation for audio setup, reverberation measurement, strip-chart recording on display, voltage and oscilloscope displays and signal generation. Supplied with field-calibrator, microphone extension cable, spare battery and software for data-download to PC. SPL facilities include time and frequency weightings: fast, slow, peak or impulse and A, C or Flat. FFT based Real Time Analysis includes 1/1, 1/3, or 1/6 octave bands with a maximum resolution of about 1/24 octave. Additional functions include spectrum subtraction, averaging, noise critera or reduction contours and reverberation-decay to ISO-20 and ISO-30. Signal-generation includes sine, square, triangle and white or pink noise.

Page 24: Test & Measurement Radio Communications Audio Visual · 2016-04-14 · Test & Measurement Radio Communications Audio Visual Test & Measurement Radio Communications Audio Visual

3

Test & Measurement

Visit our website - www.trcorporation.com

Gas Analysis & Monitoring

Testo 325M Combustion Gas AnalyserTES,325M AUPortable flue gas analyser for tuning, maintenance and service adjustments of oil and gas burners. Determines temperature (to ~500ºC), draught/pressure, oxygen (21%) and carbon monoxide (4000ppm) concentrations. Calculates carbon dioxide concentration and gross/net efficiency. Supplied as kit with probe, cordless printer and power supply for mains operation. Operation 230Vac (with power supply) or alkaline batteries (AA also required byprinter).

Testo 335 Combustion Gas AnalyserTES,335 AUPortable industrial flue gas analyser. Determines temperature (to ~1000 deg C), draught/pressure (±40hPa), oxygen (21%), carbon monoxide (10,000ppm) and nitric oxide NO (3000ppm) concentrations. Calculates carbon dioxide concentration, efficiency and flue gas loss. Threshold-protection of sensors, with 5X autodilution of CO to 50,000ppm. Separate sensor-socket with mini-probe for ambient temperature, and connection points for compatible differential-pressure devices. Built-in condensate-trap with warning and auto-switch-off. Internal memory (100 folders x 10 locations x 200 datasets each) for storage of measurement-protocols and data for printout. Supplied as kit with 335mm probe, cone and shield-plate, cordless printer and power supply. Rechargeable or ac operation (alkaline batteriesusedbyprinter).

Odalog NO2 & CO Area Monitor for vehicle-parks & IAQAPT,ODA6000CP AUPortable multi-gas monitor for area air-quality measurement, logging or personal monitoring in car-parks, loading areas and related zones. Configured for carbon monoxide (from petrol vehicles) and nitrogen dioxide (from diesel vehicles). Ranges CO 0~500ppm (to 1ppm) and NO20~50ppm (to 0.1ppm). Dust and water sealed to IP66, and rated intrinsically safe for general or mines use. Logging memory 500K readings. Integral infrared communications interface, with software and IrDA USB adaptor for configuration and download. Rechargeable, approximately 7 days operation onfullcharge.

General EnvironmentElectrochemistry, Water QualityTPS WP-80 ph MeterTPS,WP-80 AUPortable hand-held meter for pH, mV and temperature. Supplied with combination pH electrode and separate temperature sensor on 1m cables. Operating ranges 0.00~14.00pH and -10~120ºC (automatic sensor recognition with auto pH correction 0~100ºC). Case water resistant to IP67, connectors to IP65. Menu driven, with alphanumeric display. Auto storage of time and date of last calibration for GLP. Memory for 2400 readings of data, time and date, for Notepad results collection, or for AutoLog with logging intervals between 1 sec and 90 hr. Fitted with RS232C interface and supplied with download-software, charger and solutions. Rechargeable NiMH battery gives up to 50h operation.

Chemical & AnalyticalChemical & Analytical - GeneralPaar Portable Density, Specific Gravity & Concentration MeterPAA,DMA35N AURange 0~1.999 g/cc & 0~40.0ºC. Built-in pipette style pump for sample aspiration, with port for optional syringe-filling. Display of specific gravity, ºBrix, ºBaumé, %alcohol, proof, ºPlato, API, or %H2SO4. Rated intrinsically safe (ATEX) for use with batteries, petrochemicals and solvents. Data storage of up to 1,024 results, with recall, and infrared port for RS232 download to serial printer or PC. Wetted parts glass and PTFE. Battery powered.