test report 13-1-2012 bw 40-5mhz

23
69/96 M.4 Bangkadi16, Samaedum, Bangkuntien, Bangkok 10150 Thailand Tel: 081-0101006 E-mail: [email protected] Web-site: www.easynetwork.co.th Demo & Testing Report InfiNet Wireless R5000-MMX/58.80.2x63.2x23

Upload: warach-eig-watanakulchai

Post on 16-Oct-2014

104 views

Category:

Documents


5 download

TRANSCRIPT

69/96 M.4 Bangkadi16, Samaedum, Bangkuntien, Bangkok 10150 Thailand

Tel: 081-0101006 E-mail: [email protected] Web-site: www.easynetwork.co.th

Demo & Testing Report InfiNet Wireless

R5000-MMX/58.80.2x63.2x23

1). แผนท่ี The Met Condominium – คอนโดสขุใจการเ์ด้นท์ จุดยงิสญัญาณ จาก The Met Condominium ไปยงั คอนโดสุขใจการเ์ดน้ท ์ เป็นระยะทางทัง้หมด 10.3 กโิลเมตร

The Met ละตจิดู : N13°43'19.30"

ลองจจิดู : E100°32'2.90"

คอนโดสุขใจ ละตจิดู : N13°37'51.07"

ลองจจิดู : E100°31'55.20"

2). อปุกรณ์ท่ีใช้ในการทดสอบ Infinet Wireless 2.1) Infinet Wireless Model R5000 58.80.2x63.2x23

2.2) Rapid View

2.3) Computer PC

2.4) สาย LAN indoor

2.5) โปรแกรม IxChariot

2.6) Bandwidth Monitor

3.) Diagram

4). ขัน้ตอนการทดสอบ 4.1) ตรวจสอบหน้า Home \ Device Status 4.2) ตรวจสอบหน้า Spectrum Analyzer เพื่อเชค็ย่านความถี่ ของช่องสญัญาณ

4.3) ปรบัต าแหน่งของสญัญาณที ่Antenna Alignment Test ใหส้ญัญาณตรงกนั

4.4) ทดสอบสญัญาณโดยการปรบั Channel Width : 40 MHz วดัค่า Throughput จาก โปรแกรม IxChariot

4.5) ทดสอบสญัญาณโดยการปรบั Channel Width : 20 MHz วดัค่า Throughput จาก โปรแกรม IxChariot

4.6) ทดสอบสญัญาณโดยการปรบั Channel Width : 10 MHz วดัค่า Throughput จาก โปรแกรม IxChariot

4.7) ทดสอบสญัญาณโดยการปรบั Channel Width : 5 MHz วดัค่า Throughput จาก โปรแกรม IxChariot

5). สถานท่ีตัง้อปุกรณ์ ต้นทาง/ปลายทาง

5.1) สถานทีต่ัง้อุปกรณ์ ต้นทาง @The Met Condominium

คอนโดสุขใจการเ์ด้นท ์

5.2) สถานทีต่ัง้อุปกรณ์ ต้นทาง @คอนโดสุขใจ การเ์ดน้ท์

The Met Condominium

The Met Condominium

Alignment, Performance and Throughput Testing with PTP Infinet

Date: 13 Jan 2012 Distance from Master to Slave : 10.3 km. Frequency : 5690 MHz TX Power : 18 dBm

Channel Width : 40 MHz

Spectrum Analyzer

Antenna Alignment Test

Performance Test : Test Time(s) 10

Performance Test : Bidirectional Test Time(s) 10

Upload Throughput

Upload Throughput = 68.3 Mbps

Download Throughput

Download Throughput = 70.4 Mbps

Download/Upload Throughput

Download/Upload Throughput = 38.1/38.4 Mbps

Channel Width : 20 MHz

Spectrum Analyzer

Antenna Alignment Test

Performance Test : Test Time(s) 10

Performance Test : Bidirectional Test Time(s) 10

Upload Throughput

Upload Throughput = 59.8 Mbps

Download Throughput

Download Throughput = 62.4 Mbps

Download/Upload Throughput

Download/Upload Throughput = 32.5/32.3 Mbps

Channel Width : 10 MHz

Spectrum Analyzer

Antenna Alignment Test

Performance Test : Test Time(s) 10

Performance Test : Bidirectional Test Time(s) 10

Upload Throughput

Upload Throughput = 29.6 Mbps

Download Throughput

Download Throughput = 29.4 Mbps

Download/Upload Throughput

Download/Upload Throughput = 16.4/16.4 Mbps

Channel Width : 5 MHz

Spectrum Analyzer

Antenna Alignment Test

Performance Test : Test Time(s) 10

Performance Test : Bidirectional Test Time(s) 10

Upload Throughput

Upload Throughput = 17.7 Mbps

Download Throughput

Download Throughput = 18.3 Mbps

Download/Upload Throughput

Download/Upload Throughput = 10.0/10.3 Mbps

สรปุ Throughput ท่ีได้จากการทดสอบจากการก าหนดค่า Channel BW ให้กบัอปุกรณ์ Download (Mbps) Upload (Mbps) Download/Upload (Mbps) ระยะของอุปกรณ์ห่างกนัประมาณ 10 กโิลเมตร (ทดสอบ 13/01/2012) Channel BW = 40 MHz PTP 70.4 68.3 38.1/38.4 (76.5 Mbps) Channel BW = 20 MHz PTP 62.4 59.8 32.5/32.3 (64.8 Mbps) Channel BW = 10 MHz PTP 29.4 29.6 16.4/16.4 (32.8 Mbps) Channel BW = 5 MHz PTP 18.3 17.7 10.0/10.3 (20.3 Mbps)

สรปุผลการทดสอบ

PTP เมื่อท าการทดสอบทีร่ะยะ 10.3 กโิลเมตร (จากเสา The Met Condo ถ.สาธร ไปยงั อาคารสุขใจการเ์ดน้ท)์

ระดบัสญัญาณอยู่ทีป่ระมาณ Ver/Hor = -59/-62 dBm ทัง้ Slave และ Master ซึง่อยู่ในเกณฑท์ีด่ ีเมื่อท าการทดสอบ Throughput จากโปรแกรม IxChariot

ปญัหาและอุปสรรคทีพ่บ คอื การตดิตัง้ Infinet ในวนัทีท่ าการตดิตัง้ไดม้ปีรมิาณหมอกเยอะมาก ท าให้ไม่สามารถมองเหน็จุดทีย่งิสญัญาณได ้ต้องท าการเชค็ระดบัสญัญาณผ่านทาง Rapid View และ Alignment Test พืน้ที่การวางของ Infinet ฝ ัง่Slave มสีิง่กดีขวาง ท าใหส้ญัญาณโดนลดทอนไปในบางส่วน และ ความแรงของลมทีฝ่ ัง่ Slave มลีมทีแ่รงท าให ้Infinet สัน่และเกดิการแกว่งของ Chain 0,1 Signal Level

ระดบัความแรงของสญัญาณทีส่รุปไดว้่าอยู่ในเกณฑม์าตรฐาน เสถยีร เหมาะสมต่อการใชง้านจะอยู่ที ่ Ver/Hor = -70/-70 dBm หรอืสงัเกตจาก Alignment test แลว้ ระดบัสญัญาณ (Chain 0,1 Signal Level) ควรอยู่ต าแหน่ง 20dB ขึน้ไป (เขา้โซนสดี า) ดงัรปู