test report at-1500 - amazon web...

13
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. # Test is not covered under ACLASS (Certificate # AT1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally. TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5) Recipient: Rebecca Williams Date of Issue: February 13, 2014 Recipient Email: [email protected] Pages: Page 1 of 13 cc to Email: - Date Received: December 04, 2014 ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com AT-1500 Ver.01 CS-HK-RE005 SAMPLE INFORMATION: Description: Sublimation Mugs Zibo and Cactus (black and white~both sizes) Assortment: - Purchase Order Number: - SKU/style No.: - Toy Co./Agency: - Factory/Supplier/Vendor: Numo Manufacturing Country of Origin: United States Country of Distribution: United States Labeled Age Grade: - Quantity Submitted: 12 pcs per style Recommended Age Grade: - Testing Period: 02/02/2015 – 02/06/2015 02/10/2015 – 02/13/2015 Tested Age Grade: - OVERALL RESULT: PASS At the request of the client, the following tests were conducted: CONCLUSION TEST(S) CONDUCTED PASS California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior PASS California Proposition 65 Case No. CGC-04-436729, Leachable Lead & Cadmium from Tableware – Lip & Rim PASS FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior PASS Society of Glass & Ceramic Decorated Products, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim ANSECO GROUP (HK) LIMITED Vincent Chow Wai Kit Manager, Chemical Laboratory

Upload: trinhquynh

Post on 30-Aug-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 1 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

SAMPLE INFORMATION: Description: Sublimation Mugs Zibo and Cactus (black and white~both sizes)

Assortment: - Purchase Order Number: -

SKU/style No.: - Toy Co./Agency: -

Factory/Supplier/Vendor: Numo Manufacturing Country of Origin: United States

Country of Distribution: United States Labeled Age Grade: -

Quantity Submitted: 12 pcs per style Recommended Age Grade: -

Testing Period: 02/02/2015 – 02/06/2015 02/10/2015 – 02/13/2015

Tested Age Grade: -

OVERALL RESULT: PASS

At the request of the client, the following tests were conducted:

CONCLUSION TEST(S) CONDUCTED

PASS California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior

PASS California Proposition 65 Case No. CGC-04-436729, Leachable Lead & Cadmium from Tableware – Lip & Rim

PASS FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior

PASS Society of Glass & Ceramic Decorated Products, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim

ANSECO GROUP (HK) LIMITED

Vincent Chow Wai Kit Manager, Chemical Laboratory

Page 2: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 2 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]

Specimen No. 13A 13B 13C 13D 13E 13F

Volume of acid used (mL) 320 320 320 320 320 320

Element Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L

Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L

Conclusion PASS

Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)

Category Leachable Pb (mg/L)

Leachable Cd (mg/L)

X Cups and Mugs (Average of 6) 0.100 0.049

Flatware (Average of 6) 0.226 0.189

Large Hollowware (Average of 6) 0.100 0.049

Small Hollowware (Average of 6) 0.100 0.049

Pitchers (Average of 6) 0.100 0.049

Page 3: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 3 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]

Specimen No. 14A 14B 14C 14D 14E 14F

Volume of acid used (mL) 390 390 390 390 390 390

Element Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L

Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L

Conclusion PASS

Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)

Category Leachable Pb (mg/L)

Leachable Cd (mg/L)

X Cups and Mugs (Average of 6) 0.100 0.049

Flatware (Average of 6) 0.226 0.189

Large Hollowware (Average of 6) 0.100 0.049

Small Hollowware (Average of 6) 0.100 0.049

Pitchers (Average of 6) 0.100 0.049

Page 4: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 4 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]

Specimen No. 15A 15B 15C 15D 15E 15F

Volume of acid used (mL) 320 320 320 320 320 320

Element Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L

Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L

Conclusion PASS

Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)

Category Leachable Pb (mg/L)

Leachable Cd (mg/L)

X Cups and Mugs (Average of 6) 0.100 0.049

Flatware (Average of 6) 0.226 0.189

Large Hollowware (Average of 6) 0.100 0.049

Small Hollowware (Average of 6) 0.100 0.049

Pitchers (Average of 6) 0.100 0.049

Page 5: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 5 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]

Specimen No. 16A 16B 16C 16D 16E 16F

Volume of acid used (mL) 390 390 390 390 390 390

Element Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L

Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L

Conclusion PASS

Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)

Category Leachable Pb (mg/L)

Leachable Cd (mg/L)

X Cups and Mugs (Average of 6) 0.100 0.049

Flatware (Average of 6) 0.226 0.189

Large Hollowware (Average of 6) 0.100 0.049

Small Hollowware (Average of 6) 0.100 0.049

Pitchers (Average of 6) 0.100 0.049

Page 6: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 6 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

DETAILED RESULTS: California Proposition 65 Case No. CGC-04-436729, Leachable Lead & Cadmium from Tableware – Lip & Rim Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C927-80(2009)]

Specimen No. 17A 17B 17C 17D 17E 17F

Volume of acid used (mL) 200 200 200 200 200 200

Test Item Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND ND 0.5 mg/L

Cadmium (Cd) ND ND ND ND ND ND ND 2.0 mg/L

Conclusion PASS

Specimen No. 18A 18B 18C 18D 18E 18F

Volume of acid used (mL) 200 200 200 200 200 200

Test Item Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND ND 0.5 mg/L

Cadmium (Cd) ND ND ND ND ND ND ND 2.0 mg/L

Conclusion PASS

Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)

Page 7: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 7 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]

Specimen No. 13A 13B 13C 13D 13E 13F

Volume of acid used (mL) 320 320 320 320 320 320

Test Item Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L

Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L

Conclusion PASS PASS PASS PASS PASS PASS

Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)

Category Leachable Pb (mg/L)

Leachable Cd (mg/L)

X Cups and Mugs (Any of 6) 0.5 0.5

Flatware (Average of 6) 3.0 0.5

Large Hollowware (Any of 6) 1.0 0.25

Small Hollowware (Any of 6) 2.0 0.5

Pitchers (Any of 6) 0.5 0.25

Page 8: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 8 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]

Specimen No. 14A 14B 14C 14D 14E 14F

Volume of acid used (mL) 390 390 390 390 390 390

Test Item Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L

Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L

Conclusion PASS PASS PASS PASS PASS PASS

Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)

Category Leachable Pb (mg/L)

Leachable Cd (mg/L)

X Cups and Mugs (Any of 6) 0.5 0.5

Flatware (Average of 6) 3.0 0.5

Large Hollowware (Any of 6) 1.0 0.25

Small Hollowware (Any of 6) 2.0 0.5

Pitchers (Any of 6) 0.5 0.25

Page 9: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 9 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]

Specimen No. 15A 15B 15C 15D 15E 15F

Volume of acid used (mL) 320 320 320 320 320 320

Test Item Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L

Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L

Conclusion PASS PASS PASS PASS PASS PASS

Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)

Category Leachable Pb (mg/L)

Leachable Cd (mg/L)

X Cups and Mugs (Any of 6) 0.5 0.5

Flatware (Average of 6) 3.0 0.5

Large Hollowware (Any of 6) 1.0 0.25

Small Hollowware (Any of 6) 2.0 0.5

Pitchers (Any of 6) 0.5 0.25

Page 10: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 10 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]

Specimen No. 16A 16B 16C 16D 16E 16F

Volume of acid used (mL) 390 390 390 390 390 390

Test Item Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L

Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L

Conclusion PASS PASS PASS PASS PASS PASS

Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)

Category Leachable Pb (mg/L)

Leachable Cd (mg/L)

X Cups and Mugs (Any of 6) 0.5 0.5

Flatware (Average of 6) 3.0 0.5

Large Hollowware (Any of 6) 1.0 0.25

Small Hollowware (Any of 6) 2.0 0.5

Pitchers (Any of 6) 0.5 0.25

Page 11: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 11 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

DETAILED RESULTS: Society of Glass & Ceramic Decorated Products, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C927-80(2009)]

Specimen No. 17A 17B 17C 17D 17E 17F

Volume of acid used (mL) 200 200 200 200 200 200

Test Item Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND NA 4.0 mg/L

Cadmium (Cd) ND ND ND ND ND ND NA 0.4 mg/L

Conclusion PASS PASS PASS PASS PASS PASS

Specimen No. 18A 18B 18C 18D 18E 18F

Volume of acid used (mL) 200 200 200 200 200 200

Test Item Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result

Leachable Result Average Limit

Lead (Pb) ND ND ND ND ND ND NA 4.0 mg/L

Cadmium (Cd) ND ND ND ND ND ND NA 0.4 mg/L

Conclusion PASS PASS PASS PASS PASS PASS

Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)

Page 12: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 12 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

SPECIMEN DESCRIPTION:

Specimen No. Specimen Description Location

13 Bright sharp white printed dull white ceramic Interior of mug (Sublimation Mugs Zibo – White style)

14 Shiny white printed dull white ceramic Interior of mug (Sublimation Mugs Cactus – White style)

15 Bright sharp black printed dull white ceramic Interior of mug (Sublimation Mugs Zibo – White and Black style)

16 Shiny black printed dull white ceramic Interior of mug (Sublimation Mugs Cactus – White and Black style)

17 Bright sharp black/ dull off white printed dull white ceramic

Lip & rim of mug (Sublimation Mugs Zibo - White and Black style)

18 Shiny black/ off white printed dull white ceramic Lip & rim of mug (Sublimation Mugs Cactus - White and Black style)

Page 13: TEST REPORT AT-1500 - Amazon Web Servicesnumo.s3.amazonaws.com/docs/TestData-2015/Sublimation-mugs_14H... · The test result(s) and conclusion(s) in this report relate to the sample(s)

The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited. 

# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope.  ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.

                                                      TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)

Recipient: Rebecca Williams Date of Issue: February 13, 2014

Recipient Email: [email protected] Pages: Page 13 of 13

cc to Email: - Date Received: December 04, 2014

ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com

AT-1500

Ver.01CS-HK-RE005

SAMPLE PHOTO:

-End Report-