TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 1 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
SAMPLE INFORMATION: Description: Sublimation Mugs Zibo and Cactus (black and white~both sizes)
Assortment: - Purchase Order Number: -
SKU/style No.: - Toy Co./Agency: -
Factory/Supplier/Vendor: Numo Manufacturing Country of Origin: United States
Country of Distribution: United States Labeled Age Grade: -
Quantity Submitted: 12 pcs per style Recommended Age Grade: -
Testing Period: 02/02/2015 – 02/06/2015 02/10/2015 – 02/13/2015
Tested Age Grade: -
OVERALL RESULT: PASS
At the request of the client, the following tests were conducted:
CONCLUSION TEST(S) CONDUCTED
PASS California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior
PASS California Proposition 65 Case No. CGC-04-436729, Leachable Lead & Cadmium from Tableware – Lip & Rim
PASS FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior
PASS Society of Glass & Ceramic Decorated Products, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim
ANSECO GROUP (HK) LIMITED
Vincent Chow Wai Kit Manager, Chemical Laboratory
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 2 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 13A 13B 13C 13D 13E 13F
Volume of acid used (mL) 320 320 320 320 320 320
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS
Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 3 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 14A 14B 14C 14D 14E 14F
Volume of acid used (mL) 390 390 390 390 390 390
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS
Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 4 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 15A 15B 15C 15D 15E 15F
Volume of acid used (mL) 320 320 320 320 320 320
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS
Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 5 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. 938430, Leachable Lead & Cadmium from Tableware (Shipment under 2,000 Pieces) – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 16A 16B 16C 16D 16E 16F
Volume of acid used (mL) 390 390 390 390 390 390
Element Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.100 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 0.049 mg/L
Conclusion PASS
Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Average of 6) 0.100 0.049
Flatware (Average of 6) 0.226 0.189
Large Hollowware (Average of 6) 0.100 0.049
Small Hollowware (Average of 6) 0.100 0.049
Pitchers (Average of 6) 0.100 0.049
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 6 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
DETAILED RESULTS: California Proposition 65 Case No. CGC-04-436729, Leachable Lead & Cadmium from Tableware – Lip & Rim Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C927-80(2009)]
Specimen No. 17A 17B 17C 17D 17E 17F
Volume of acid used (mL) 200 200 200 200 200 200
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 2.0 mg/L
Conclusion PASS
Specimen No. 18A 18B 18C 18D 18E 18F
Volume of acid used (mL) 200 200 200 200 200 200
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND ND 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND ND 2.0 mg/L
Conclusion PASS
Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 7 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 13A 13B 13C 13D 13E 13F
Volume of acid used (mL) 320 320 320 320 320 320
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS
Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 8 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 14A 14B 14C 14D 14E 14F
Volume of acid used (mL) 390 390 390 390 390 390
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS
Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 9 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 15A 15B 15C 15D 15E 15F
Volume of acid used (mL) 320 320 320 320 320 320
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS
Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 10 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
DETAILED RESULTS: FDA CPG 545.400 & CPG 545.450, Leachable Cadmium & Lead from Ceramics – Interior Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C738-94(Reapproved 2011)]
Specimen No. 16A 16B 16C 16D 16E 16F
Volume of acid used (mL) 390 390 390 390 390 390
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 0.5 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.5 mg/L
Conclusion PASS PASS PASS PASS PASS PASS
Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
Category Leachable Pb (mg/L)
Leachable Cd (mg/L)
X Cups and Mugs (Any of 6) 0.5 0.5
Flatware (Average of 6) 3.0 0.5
Large Hollowware (Any of 6) 1.0 0.25
Small Hollowware (Any of 6) 2.0 0.5
Pitchers (Any of 6) 0.5 0.25
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 11 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
DETAILED RESULTS: Society of Glass & Ceramic Decorated Products, Leachable Lead & Cadmium from Glassware and Ceramics – Lip & Rim Analysis performed by Inductively Coupled Plasma-Optical Emission Spectrometry to determine compliance with the above referenced specification. [Referenced Test Method: ASTM C927-80(2009)]
Specimen No. 17A 17B 17C 17D 17E 17F
Volume of acid used (mL) 200 200 200 200 200 200
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 4.0 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.4 mg/L
Conclusion PASS PASS PASS PASS PASS PASS
Specimen No. 18A 18B 18C 18D 18E 18F
Volume of acid used (mL) 200 200 200 200 200 200
Test Item Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result
Leachable Result Average Limit
Lead (Pb) ND ND ND ND ND ND NA 4.0 mg/L
Cadmium (Cd) ND ND ND ND ND ND NA 0.4 mg/L
Conclusion PASS PASS PASS PASS PASS PASS
Note: NA = Not applicable mL = millilitres LT = Less than ND = Not Detected (Reporting Limit: Pb = 0.04mg/L; Cd = 0.02mg/L) Results are reported in milligrams per litre (mg/L) or parts per million (ppm)
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 12 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
SPECIMEN DESCRIPTION:
Specimen No. Specimen Description Location
13 Bright sharp white printed dull white ceramic Interior of mug (Sublimation Mugs Zibo – White style)
14 Shiny white printed dull white ceramic Interior of mug (Sublimation Mugs Cactus – White style)
15 Bright sharp black printed dull white ceramic Interior of mug (Sublimation Mugs Zibo – White and Black style)
16 Shiny black printed dull white ceramic Interior of mug (Sublimation Mugs Cactus – White and Black style)
17 Bright sharp black/ dull off white printed dull white ceramic
Lip & rim of mug (Sublimation Mugs Zibo - White and Black style)
18 Shiny black/ off white printed dull white ceramic Lip & rim of mug (Sublimation Mugs Cactus - White and Black style)
The test result(s) and conclusion(s) in this report relate to the sample(s) tested as described herein. This test report may not be reproduced in whole or in part, without written approval of ANSECO Group (HK) Limited.
# Test is not covered under ACLASS (Certificate # AT‐1500) accredited listed scope. ACLASS is recognized by ILAC, APLAC and IAAC as a signatory of multilateral recognition arrangements that facilitate acceptance of test internationally.
TEST REPORT Company: Numo Manufacturing Test Report # 14H-04201(A5)
Recipient: Rebecca Williams Date of Issue: February 13, 2014
Recipient Email: [email protected] Pages: Page 13 of 13
cc to Email: - Date Received: December 04, 2014
ANSECO GROUP (HK) LIMITED 14/F, Yoo Hoo Tower, 38-42 Kwai Fung Crescent, Kwai Chung N.T., Hong Kong Tel: 852-3185 8000 Fax: 852-3572 0374 ansecogroup.com
AT-1500
Ver.01CS-HK-RE005
SAMPLE PHOTO:
-End Report-