test report n° 113749 - arredaclick · pdf filevia ca' leoncino, 2 31030 castello di...

7
Date received: 16-02-10 Date of issue: 15-03-10 Report consists of 5 attached sheets. Sample name: NOW TEST REPORT N° 113749 List performed tests 1. Seat and back static load test EN 1728:2000 2. Seat and back fatigue test EN 1728:2000 3. Seat front edge durability test EN 1728:2000 4. Seat impact test EN 1728:2000 5. Back impact test EN 1728:2000 OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer. CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. 1.003.650,00 i.v. Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected] Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected] centro ricerche-sviluppo laboratorio prove settore legno-arredo Page 1 of 2 This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems. Managing Director Dr. Andrea Giavon Defects before testing: None Overall dimensions: 510 x 520 x 860 (h) mm (extended uncertainty = 5 mm)

Upload: ngominh

Post on 21-Feb-2018

213 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: TEST REPORT N° 113749 - ArredaClick · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italy

Date received: 16-02-10

Date of issue: 15-03-10

Report consists of 5 attached sheets.

Sample name: NOW

TEST REPORT N° 113749

List performed tests

1. Seat and back static load test EN 1728:2000!2. Seat and back fatigue test EN 1728:2000!3. Seat front edge durability test EN 1728:2000!4. Seat impact test EN 1728:2000!5. Back impact test EN 1728:2000!

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

centro ricerche-sviluppo laboratorio prove settore legno-arredo

Page 1 of 2

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Defects before testing: None

Overall dimensions: 510 x 520 x 860 (h) mm (extended uncertainty = 5 mm)

Page 2: TEST REPORT N° 113749 - ArredaClick · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italy

Date of issue: 15-03-10

Sample name: NOW

TEST REPORT N° 113749

Page 2 of 2

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

Side view Rear view

Bottom view

Sample weightOverall dimensions

Not determined510 x 520 x 860 (h) mm (*)

(*) Extended uncertainties of weight and overall dimensions of the sample are 0,1 Kg and 5 mm, respectively

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

centro ricerche-sviluppo laboratorio prove settore legno-arredo

Page 3: TEST REPORT N° 113749 - ArredaClick · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italy

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

113749 / 1Date received: 16-02-10Date of test: 25-02-10Date of issue: 15-03-10Sample name: NOW

Seat and back static load test EN 1728:2000

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Test results:

Back forceN

Numberof cycles Remarks

Seat and back static load test, clause 6.2.1

Seat loadN

1.600 560 10 No defects

Seat front edge static load, clause 6.2.2

Numberof cycles RemarksSeat load

N

1.600 10 No defects

The test has been carried out according to table 1 of EN 15373:2007, level 2 - general.Note:

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 4: TEST REPORT N° 113749 - ArredaClick · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italy

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

113749 / 2Date received: 16-02-10Date of test: 26-02-10Date of issue: 15-03-10Sample name: NOW

Seat and back fatigue test EN 1728:2000

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Test results:

Back forceN

Numberof cycles Remarks

Seat and back fatigue test, clause 6.7

Seat forceN

1.000 300 100.000 No defects

Note:The test has been carried out according to table 1 of EN 15373:2007, level 2 - general.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 5: TEST REPORT N° 113749 - ArredaClick · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italy

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

113749 / 3Date received: 16-02-10Date of test: 10-03-10Date of issue: 15-03-10Sample name: NOW

Seat front edge durability test EN 1728:2000

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Test results:

Seat forceN

Number ofcycles Remarks

Seat front edge durability test, clause 6.8

Points ofapplication

80 mm back fromthe front edge 1.000 50.000 No defects

Note:The test has been carried out according to table 1 of EN 15373:2007, level 2 - general.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 6: TEST REPORT N° 113749 - ArredaClick · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italy

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

113749 / 4Date received: 16-02-10Date of test: 15-03-10Date of issue: 15-03-10Sample name: NOW

Seat impact test EN 1728:2000

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Test results:

Heightof drop

mmNumberof drops Remarks

Seat impact test, clause 6.15

Mass ofimpactor

kg

25 240 10 No defects

Note:The test has been carried out according to table 1 of EN 15373:2007, level 2 - general.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon

Page 7: TEST REPORT N° 113749 - ArredaClick · PDF filevia ca' leoncino, 2 31030 castello di godego (tv) italy

CATAS S.p.A. Iscr. Reg. Imprese Udine nr. iscr. C.F. 01818850305 Reg. Impr. UD 20663 P. IVA : 01818850305 C.Soc. € 1.003.650,00 i.v.

centro ricerche-sviluppo laboratorio prove settore legno-arredo

TEST REPORT

113749 / 5Date received: 16-02-10Date of test: 15-03-10Date of issue: 15-03-10Sample name: NOW

Back impact test EN 1728:2000

OMP S.R.L. VIA CA' LEONCINO, 2 31030 CASTELLO DI GODEGO (TV) ITALY

Sede: Via Antica, 24/3 33048 S. Giovanni al Nat. UD Tel. 0432.747211 r.a. Fax 0432.747250 http://www.catas.com e-mail: [email protected]

Filiale: Via Braille, 5 20035 Lissone MB Tel. 039.464567 Fax 039.464565 e-mail: [email protected]

Test results:

Mass ofimpactor

kgNumberof cycles Remarks

Back impact test, clause 6.16

Angle°

48 6,5 10 No defects

Note:The test has been carried out according to table 1 of EN 15373:2007, level 2 - general.

pag. 1/1

The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

Managing Director Dr. Andrea Giavon