test report of ies lm 79 08 approved method: …...shenzhen belling efficiency testing lab report...

17
Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Applicant: Beyond LED Technology Address: 1939 Parker Ct Suite C Stone Mountain, GA 30087 For Product: Prime Series Traditional LED Wall Packs Model No.: BLTHWP120XA1abc Test laboratory: Shenzhen Belling Efficiency Testing Lab., 1/F., Building 1, 1F, No.1 building, Meibaohe industrial park, Dalang street, Shenzhen, Guangdong Prov.518101, China. Complied by: Ike Li Review by: Jason zhou Project Engineer Technical Manager Note: This test report is perpared for the customer shown above and for the device described herein. It may not be duplicated or use in part without prior written consent from Shenzhen Belling Efficiency Testing Lab. This report must not be used by the customer to claim product certification, approval, or endorsement By NVLAP, NIST, or any agency of the Federal Government. Date of issue 2018-01-06 Version 1.0 Total pages 17

Upload: others

Post on 22-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

Test report of IES LM-79-08

Approved Method: Electrical and Photometric

Measurements of Solid-State Lighting Products

Applicant:

Beyond LED Technology

Address:

1939 Parker Ct Suite C

Stone Mountain, GA 30087

For Product:

Prime Series Traditional LED Wall Packs

Model No.: BLTHWP120XA1abc

Test laboratory: Shenzhen Belling Efficiency Testing Lab., 1/F., Building 1, 1F, No.1 building, Meibaohe

industrial park, Dalang street, Shenzhen, Guangdong Prov.518101, China.

Complied by: Ike Li Review by: Jason zhou

Project Engineer Technical Manager

Note: This test report is perpared for the customer shown above and for the device described herein. It may not

be duplicated or use in part without prior written consent from Shenzhen Belling Efficiency Testing Lab. This

report must not be used by the customer to claim product certification, approval, or endorsement By NVLAP,

NIST, or any agency of the Federal Government.

Date of issue 2018-01-06

Version 1.0

Total pages 17

Page 2: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 2 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

1 General 1.1 Product Information

Manufacturer SHENZHEN SNC OPTO ELECTRONIC CO LTD

Manufacturer Address 1939 Parker Ct Suite C Stone Mountain, GA 30087

Brand Name Beyond LED

Luminaire Type Prime Series Traditional LED Wall Packs

Model Number

BLTHWP120XA1abc

BLT = Company name

HWP = Product series

120 = Rating Power

A = LED type, hongli 2835

A1 = Version number

a = S or blank. "S" represent Surge-Protective Device, or blank

represent None Surge-Protective Device

b = P or blank. "P" represent Photocontroller , or blank represent None

Photocontroller

c = CCT, can be 40,45,50,57

Rated Inputs AC 100-277V 50/60Hz

Rated Power 120 W

Nominal CCT 5000K

LED Package, Array or Module Hongli Zhihui Group Co., Ltd

HL-AS-PU2835DW-S1-08-PCT-HR3

Date of Receipt Samples 2017-12-29

1.2 Standards or methods

ANSI C78.377-2011:Specifications for the Chromaticity of Solid State Lighting Products

ANSI C82.77-2002: Harmonic Emission Limits-Related Power Quality Requirements for

Lighting Equipment

CIE Publication No.13.3-1995:Method of Measuring and Specifying Color Rendering of Light

Sources

Page 3: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 3 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

IESNA LM-79-08 Approved Method: Electric & Photometric Measurement of Solid-state

Lighting Products

Page 4: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 4 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

1.3 Equipment list

Device Manufacture Model No. Serial No. Calibration

due date

Goniophotometeric System SENSING GMS-3000 N.A 2018-09-20

AC Power Source ALL POWER APW-110N 992257 2018-08-26

Total Luminous Flux Standard Lamp

SENSING 110V/100W S13100234 2018-09-14

Digital Power Meter YOKOGAWA WT310 C2QM02030V 2018-08-28

Integral Sphere (2M) SENSING SD-20 N.A 2018-08-26

Digital Power Meter YOKOGAWA WT210 91L929742 2018-08-28

Optical Color and Electrical Measurement System

SENSING SPR-3000 N.A 2018-08-26

Temperature/humidity/clock VICTOR VC230 57636 2018-09-12

Digital Anemometer TECMAN TD8901 026141 2018-09-12

Statement of Traceability: Shenzhen Belling Efficiency Testing Lab attests that all calibration has been

performed using suitable standards traceable to national primary standards and International System of

Unit (SI).

Page 5: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 5 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

2 Test conducted and method 2.1 Ambient Condition

The ambient temperature in which measurements are being taken was maintained at 25°C ±1°C, the air

flow around the sample(s) being tested did not affect the performance.

2.2 Power Supply Characteristics

The AC power supply had a sinusoidal voltage wave shape at the prescribed frequency (60 Hz) such that

the RMS summation of the harmonic components does not exceed 3 percent of the fundamental during

operation of the test item.

The voltage of AC power supply (RMS voltage) applied to the device under test was regulated to

within±0.2 percent under load.

2.3 Seasoning and Stabilization

No seasoning was performed in accordance with IESNA LM-79-08. And before the measurement, the

sample was stabilized until the light output and power variations were less than 0.5% in 30 minutes

intervals (3 readings, 15 minutes apart).

2.4 Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and

integrating sphere. The integrating sphere system is calibrated by standard light source before

measurement. The system and standard light source has been calibrated regularly and traceable to the

National Primary Standards. 4π geometry was used during measurement. The product was operated in its

intended orientation in application and was recorded in this report.

2.5 Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement. The standard light

source has been calibrated regularly and traceable to the National Primary Standards.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and

color spatial uniformity. The product was operated in its intended orientation in application and was

recorded in this report. The method according to IESNA LM-79-08 following chapter.

Page 6: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 6 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

3 Test Result Summary

3.1 Integrating Sphere System

3.1.1 Electrical data

Model Number Input

Voltage(V)

Frequency

(Hz)

BLTHWP120XA1abc 120 60

3.1.3 Photometric data

Model Number CCT (K) CRI R9

BLTHWP120XA1abc 5620 83.8 7

3.1.3 Chromaticity Coordinate

Model Number Duv x, y u', v'

BLTHWP120XA1abc 0.0020 x=0.3297 y=0.3425 u(u')=0.2045 v'=0.4779

Spectral Power Distribution & Chromaticity Diagram / Model SNC-SWP01-120AA1-ab40

Spectral Power Distribution & Chromaticity Diagram / Model SNC-SWP01-120AA1-ab57

Page 7: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 7 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

3.2 Goniophotometer System

3.2.1 Electrical data

Model Number Input

Voltage(V)

Frequency

(Hz)

Input

Current (A) Power (W)

Power

factor

THD, %

BLTHWP120XA1abc120 60 0.9974 119.21 0.996 6.2

3.2.2 Photometric data

Model Number

Input Voltage(V) Luminous Flux

(lm), 0-90°

Efficacy (lm/W) ,

0-90°

Zonal Lumen in

80-90°/0-90°

(%lm)

BLTHWP120XA1abc 120 15101 126.68 --

3.2.3 Calculated Efficacy Data for family models (4500K and 5000K):

Model Number Luminous Flux

(lm)

Power

(W) Efficacy (lm/W)

BLTHWP120XA1abc 15483.4 119.39 129.69

Page 8: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 8 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

Zonal Lumen Tabulation

Zonal Lumen Summary

Zone Lumens % Lamp % Luminaire

0-30 3,399.5 22% 22%

0-40 5,450.1 35.3% 35.3%

0-60 9,941.3 64.4% 64.4%

60-90 4,601.5 29.8% 29.8%

70-100 3,072.1 19.9% 19.9%

90-120 826.8 5.4% 5.4%

0-90 14,542.7 94.2% 94.2%

90-180 901.9 5.8% 5.8%

0-180 15,444.7 100% 100%

Lumens Per Zone

Zone Lumens % Total Zone Lumens % Total

0-10 438.0 2.8% 90-100 504.3 3.3%

10-20 1,225.6 7.9% 100-110 225.1 1.5%

20-30 1,735.9 11.2% 110-120 97.4 0.6%

30-40 2,050.7 13.3% 120-130 48.4 0.3%

40-50 2,226.7 14.4% 130-140 20.4 0.1%

50-60 2,264.5 14.7% 140-150 4.6 0%

60-70 2,033.6 13.2% 150-160 1.0 0%

70-80 1,565.2 10.1% 160-170 0.6 0%

80-90 1,002.6 6.5% 170-180 0.2 0%

Page 9: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 9 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

Photometric Data

Page 10: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 10 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

Luminous Intensity Distribution Data

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 4741 4741 4741 4741 4741 4741 4741 4741 4741 4741 4741 4741 4741 4741 4741 4741 4741

1 5591 5519 5352 4988 4738 4652 4746 4781 4786 4779 4729 4616 4754 5093 5422 5594 5591

2 5024 5225 5609 5415 4742 4737 4557 4142 3982 4131 4528 4696 4764 5509 5619 5227 5024

3 3919 3977 4870 5596 4707 4706 3987 4187 4403 4231 3932 4688 4743 5649 4826 3991 3919

4 4820 4328 3919 5483 4666 4403 4246 4790 4845 4763 4208 4404 4722 5474 3940 4350 4820

5 6200 5848 4149 5147 4667 4060 4668 4785 4363 4790 4664 4056 4725 5116 4210 6025 6200

6 4955 5481 5062 4604 4633 4014 4863 3977 3843 3980 4819 3942 4711 4527 5246 5441 4955

7 4929 4923 6059 4086 4581 4182 4430 3905 4017 3897 4447 4107 4671 4044 6152 4934 4929

8 5245 4893 5434 3909 4554 4398 3909 4035 4014 4045 3921 4356 4638 3950 5305 4947 5245

9 5148 5340 4903 4012 4548 4565 3854 4021 4073 4020 3843 4518 4595 4138 4920 5374 5148

10 5169 5097 4776 4240 4508 4687 3944 3990 3776 4003 3941 4613 4567 4415 4817 5121 5169

11 5240 5129 4855 4541 4470 4672 3955 3696 3506 3715 3955 4643 4539 4826 5031 5146 5240

12 5582 5209 5298 4992 4417 4452 3980 3485 3529 3477 3956 4489 4481 5430 5369 5253 5582

13 5473 5591 5061 5547 4367 4126 3909 3501 3520 3505 3907 4189 4420 5873 5020 5632 5473

14 5293 5392 4943 5770 4325 3869 3679 3486 3324 3492 3702 3915 4384 5837 4981 5395 5293

15 5213 5243 5003 5575 4275 3739 3461 3326 3295 3340 3498 3757 4337 5359 5113 5266 5213

16 5573 5106 5145 5102 4215 3704 3343 3231 3138 3241 3361 3693 4277 4892 5314 5195 5573

17 5452 5346 5290 4713 4164 3667 3341 3123 3029 3145 3353 3646 4204 4665 5407 5457 5452

18 5284 5378 5131 4543 4128 3640 3308 2985 2946 2997 3319 3630 4134 4568 5164 5415 5284

19 5403 5227 4956 4430 4106 3607 3190 2947 2788 2947 3197 3600 4103 4451 5005 5309 5403

20 5490 5212 4910 4300 4086 3563 3067 2809 2641 2820 3086 3580 4082 4364 4983 5315 5490

21 5420 5238 4870 4233 4048 3544 2994 2640 2514 2659 3020 3558 4041 4402 4948 5341 5420

22 5302 5304 4811 4294 4001 3506 2881 2531 2432 2542 2898 3504 3994 4533 4938 5347 5302

23 5394 5170 4836 4414 3962 3413 2762 2413 2296 2417 2781 3426 3944 4678 4972 5224 5394

24 5684 5159 4835 4527 3905 3292 2684 2295 2145 2310 2705 3323 3929 4730 4948 5230 5684

25 5725 5235 4834 4604 3824 3174 2584 2193 2028 2206 2621 3216 3879 4664 4925 5332 5725

26 5800 5412 4696 4601 3769 3057 2489 2056 1886 2062 2507 3122 3812 4550 4763 5501 5800

27 5605 5444 4578 4400 3685 2944 2371 1943 1770 1952 2404 3019 3756 4364 4677 5563 5605

28 5708 5473 4515 4193 3626 2861 2264 1804 1640 1815 2306 2904 3692 4196 4628 5593 5708

29 5750 5448 4546 4028 3579 2780 2153 1683 1493 1702 2206 2825 3639 4077 4700 5525 5750

Page 11: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 11 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

30 5976 5358 4568 3995 3498 2717 2065 1580 1376 1581 2115 2757 3581 4109 4665 5453 5976

31 5891 5439 4461 4061 3451 2665 1972 1450 1274 1463 2020 2717 3505 4219 4543 5554 5891

32 5845 5673 4416 4075 3429 2591 1874 1343 1183 1360 1928 2662 3449 4317 4511 5825 5845

33 5805 5534 4418 4047 3394 2518 1760 1248 1107 1261 1822 2614 3411 4292 4534 5649 5805

34 6004 5434 4559 4041 3366 2451 1667 1161 1030 1163 1727 2551 3388 4255 4706 5597 6004

35 6049 5392 4635 4058 3333 2363 1599 1079 967 1084 1652 2470 3370 4190 4738 5518 6049

36 6050 5737 4516 4044 3324 2280 1511 1008 911 1010 1571 2405 3333 4109 4627 5843 6050

37 6001 5640 4398 3990 3267 2177 1425 943 846 940 1499 2335 3306 4053 4535 5733 6001

38 6096 5428 4385 3934 3218 2118 1344 878 790 881 1414 2227 3299 3984 4530 5606 6096

39 6143 5364 4589 3781 3179 2045 1269 824 739 827 1341 2174 3256 3891 4677 5514 6143

40 6136 5706 4494 3664 3105 1979 1203 774 689 780 1277 2133 3241 3753 4604 5862 6136

41 6052 5781 4411 3579 3037 1909 1125 726 639 731 1210 2057 3177 3655 4540 5907 6052

42 6086 5532 4301 3516 2951 1832 1062 673 599 680 1137 1998 3149 3635 4479 5684 6086

43 6298 5336 4311 3512 2907 1772 994 632 563 638 1080 1921 3082 3644 4540 5482 6298

44 6355 5559 4528 3512 2821 1712 940 593 532 598 1021 1872 3033 3614 4611 5686 6355

45 6182 5735 4307 3455 2754 1646 881 558 499 558 964 1781 2940 3534 4426 5922 6182

46 6286 5591 4303 3333 2670 1564 825 522 468 524 907 1716 2860 3452 4446 5806 6286

47 6416 5444 4318 3262 2607 1511 777 490 440 493 851 1646 2812 3413 4475 5631 6416

48 6393 5611 4471 3247 2548 1436 715 457 412 458 797 1556 2733 3435 4584 5828 6393

49 6311 5753 4404 3273 2467 1355 667 424 395 428 748 1479 2661 3495 4422 5977 6311

50 6303 5617 4198 3402 2428 1293 625 397 379 400 700 1405 2597 3618 4245 5820 6303

51 6402 5460 4156 3453 2371 1225 589 376 365 379 652 1331 2534 3635 4318 5644 6402

52 6368 5595 4346 3302 2326 1175 559 356 351 360 608 1251 2474 3476 4598 5789 6368

53 6241 5619 4487 3167 2253 1105 532 336 338 340 578 1178 2429 3339 4601 5861 6241

54 5998 5466 4105 3112 2204 1039 502 319 324 324 547 1108 2368 3309 4246 5703 5998

55 5952 5359 4027 3119 2136 976 477 305 302 307 519 1028 2319 3299 4216 5584 5952

56 6193 5434 4151 3177 2086 912 452 290 284 293 492 956 2268 3434 4316 5594 6193

57 5700 5327 4312 3209 2033 864 429 274 264 277 465 878 2202 3421 4530 5542 5700

58 5448 5201 4104 3110 1982 817 408 261 243 266 441 819 2158 3279 4234 5399 5448

59 5686 5090 4020 3009 1916 767 386 247 225 252 418 767 2080 3175 4156 5200 5686

60 5805 4901 4015 2999 1831 720 368 232 210 235 395 715 2026 3212 4201 5039 5805

61 5057 5062 4025 2923 1756 675 349 217 195 220 373 671 1954 3183 4195 5219 5057

62 4677 4709 3848 2887 1679 634 327 204 181 206 348 628 1865 3118 4060 4862 4677

Page 12: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 12 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

63 6506 4143 3738 2859 1600 588 304 188 168 191 324 582 1796 3039 3881 4302 6506

64 6253 4690 3662 2828 1518 550 285 173 154 175 303 552 1708 3063 3819 4915 6253

65 5236 5611 3702 2770 1427 524 263 159 142 162 282 526 1620 2998 3875 5835 5236

66 4557 4939 3591 2677 1342 494 242 145 128 147 258 504 1542 2911 3760 5109 4557

67 4841 4097 3290 2618 1240 464 224 132 116 134 236 479 1442 2847 3433 4275 4841

68 4655 4061 3337 2586 1146 437 208 119 106 120 218 455 1346 2831 3509 4212 4655

69 4823 4023 3729 2506 1055 408 192 107 96 109 203 430 1250 2710 3909 4144 4823

70 5075 3967 3374 2430 961 383 179 95 87 96 189 405 1138 2639 3529 4139 5075

71 4990 4293 2977 2375 868 358 163 84 77 85 173 382 1037 2609 3147 4491 4990

72 4566 4292 2928 2311 775 336 148 72 68 73 159 361 925 2518 3068 4423 4566

73 4338 3864 2754 2186 697 311 134 61 59 63 144 340 830 2391 2877 4053 4338

74 4136 3631 2815 2100 619 289 121 52 49 52 130 316 740 2375 2999 3795 4136

75 3949 3454 2930 2117 562 267 107 41 39 42 117 295 649 2350 3090 3632 3949

76 4098 3362 2776 1959 511 248 93 29 29 30 104 275 575 2217 2975 3556 4098

77 4034 3418 2564 1842 473 231 80 19 15 19 91 256 522 2086 2793 3589 4034

78 3686 3306 2435 1708 439 215 66 6 3 6 77 239 475 1954 2645 3471 3686

79 3534 3059 2336 1626 403 198 51 2 2 2 62 224 439 1858 2582 3205 3534

80 3336 2901 2326 1605 379 184 37 1 3 2 46 209 403 1850 2558 3061 3336

81 3215 2750 2222 1494 355 172 34 2 3 3 42 192 375 1760 2453 2925 3215

82 3250 2657 2089 1395 333 162 32 2 2 3 39 180 353 1644 2326 2820 3250

83 2999 2592 2025 1305 308 152 29 3 3 3 36 168 332 1518 2249 2732 2999

84 2750 2387 1924 1206 290 144 27 2 2 3 33 158 313 1420 2137 2536 2750

85 2732 2231 1843 1118 273 137 25 2 3 3 31 148 298 1325 2049 2408 2732

86 2560 2147 1735 1031 259 131 22 2 3 2 27 139 284 1227 1965 2328 2560

87 2420 1978 1645 958 250 123 20 3 2 2 24 132 275 1134 1864 2215 2420

88 2208 1859 1568 870 241 118 19 2 3 3 23 126 262 1035 1797 2085 2208

89 2041 1737 1478 803 232 112 17 2 3 3 21 120 251 951 1687 1971 2041

90 1958 1622 1413 731 222 108 15 2 3 2 19 113 242 875 1615 1857 1958

91 1856 1525 1332 669 212 102 14 3 2 3 17 108 231 806 1528 1754 1856

92 1681 1397 1257 608 201 98 11 2 3 2 15 101 220 728 1457 1613 1681

93 1577 1279 1167 556 192 92 11 3 3 3 14 95 209 666 1369 1473 1577

94 1381 1135 1077 510 181 88 10 2 3 3 12 90 197 605 1272 1325 1381

95 1303 1017 1001 466 172 83 8 2 3 3 11 85 186 547 1181 1185 1303

Page 13: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 13 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

96 1084 951 922 430 164 78 8 2 2 3 10 81 175 497 1088 1081 1084

97 930 846 850 390 156 73 7 3 3 3 9 76 163 449 1006 975 930

98 786 742 783 363 148 68 6 2 2 2 7 71 155 407 924 903 786

99 638 688 717 337 141 63 6 2 2 3 6 66 147 377 857 821 638

100 609 642 677 314 134 59 4 2 3 2 5 61 139 349 811 763 609

101 630 618 624 291 130 54 4 2 3 3 5 57 132 322 745 734 630

102 623 594 575 272 124 51 4 3 3 3 4 52 126 301 689 686 623

103 606 565 529 257 120 47 3 2 3 3 4 49 120 282 634 659 606

104 600 544 481 241 115 43 2 2 3 3 3 45 115 264 580 616 600

105 566 503 438 224 110 40 2 2 2 2 2 41 109 245 528 571 566

106 519 471 399 211 106 37 3 2 3 2 2 39 104 230 481 538 519

107 478 434 355 199 102 35 2 3 3 3 2 35 100 215 432 503 478

108 436 397 321 187 99 32 2 2 3 3 2 32 96 203 391 454 436

109 393 365 289 177 95 29 2 3 3 3 2 29 92 191 349 423 393

110 345 333 261 166 92 27 2 2 2 3 2 26 87 178 314 389 345

111 295 305 244 156 88 25 2 3 2 3 2 24 83 167 290 357 295

112 242 284 228 145 83 23 2 2 3 3 2 22 80 156 270 328 242

113 210 260 214 135 79 21 2 2 2 3 2 20 76 146 251 303 210

114 189 241 202 128 75 20 2 3 3 3 2 18 71 136 237 281 189

115 168 224 192 121 71 18 2 3 3 3 2 16 67 128 223 261 168

116 158 207 181 113 68 16 2 3 3 3 2 15 63 121 210 245 158

117 153 192 172 106 62 14 2 3 3 3 2 13 59 112 199 228 153

118 147 183 165 100 59 13 2 3 2 3 2 13 55 105 188 217 147

119 141 176 159 92 55 13 2 3 3 4 2 11 50 98 178 206 141

120 137 167 154 87 50 11 2 3 4 4 2 9 46 91 171 196 137

121 134 158 148 80 46 11 2 3 3 3 2 9 42 84 165 183 134

122 131 147 145 74 43 9 2 3 3 3 3 8 38 77 160 170 131

123 130 137 140 68 40 9 2 3 3 3 2 7 34 71 155 158 130

124 128 127 134 63 37 9 2 3 3 4 2 5 29 64 148 148 128

125 123 116 128 58 33 7 3 2 4 4 3 4 26 60 141 136 123

126 119 106 122 54 30 7 2 3 4 4 2 3 22 55 133 125 119

127 113 102 115 50 27 6 2 3 4 4 3 3 20 50 126 119 113

128 103 99 109 45 24 6 2 3 3 4 3 3 15 45 118 116 103

Page 14: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 14 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

129 95 95 101 42 22 6 2 3 2 4 3 3 12 40 111 111 95

130 93 92 94 38 19 5 3 3 4 3 3 3 10 37 104 106 93

131 91 87 85 34 17 4 3 3 3 3 3 3 8 34 96 101 91

132 87 82 76 32 14 4 2 2 4 4 3 3 6 30 87 96 87

133 83 78 67 28 11 3 2 3 3 3 3 2 6 28 77 90 83

134 80 73 58 24 10 3 3 3 3 4 3 3 5 25 67 85 80

135 76 69 50 22 8 4 2 3 3 4 3 3 4 23 58 79 76

136 72 65 42 19 6 4 3 3 3 3 3 3 4 19 49 74 72

137 67 61 33 16 5 3 3 3 3 2 3 3 4 18 39 70 67

138 64 59 26 14 4 4 2 3 3 3 3 3 3 15 31 65 64

139 61 53 19 12 4 4 2 3 3 3 3 3 3 14 23 60 61

140 58 47 12 11 3 4 2 3 3 4 2 3 3 12 17 53 58

141 56 40 9 9 3 4 2 3 3 4 3 3 2 10 8 45 56

142 49 34 6 6 3 3 3 3 3 3 2 3 2 8 4 39 49

143 42 28 4 7 2 3 2 3 3 3 3 3 2 8 4 32 42

144 34 22 4 6 3 4 3 3 3 3 2 3 2 6 4 25 34

145 28 17 3 5 3 3 3 3 3 3 2 3 1 5 3 19 28

146 22 11 2 3 3 4 2 2 3 3 3 4 1 4 2 14 22

147 15 7 1 3 3 3 2 2 3 3 2 3 2 3 1 9 15

148 11 3 1 2 2 3 2 3 3 3 2 4 1 3 1 5 11

149 8 2 1 2 3 3 2 2 3 3 3 3 2 2 2 2 8

150 5 2 1 2 2 2 2 2 3 3 2 3 2 2 2 1 5

151 1 1 1 2 3 3 2 2 2 3 3 3 2 3 1 2 1

152 1 1 1 2 3 3 2 3 3 3 3 4 1 2 1 1 1

153 2 2 1 2 2 3 2 2 3 3 3 3 2 2 1 1 2

154 2 1 1 2 3 3 2 2 3 3 2 3 1 2 2 1 2

155 1 1 1 2 3 3 2 3 3 2 2 3 2 2 1 2 1

156 2 1 1 2 3 2 2 2 3 3 3 4 2 3 1 2 2

157 2 1 1 1 2 3 2 3 2 3 3 3 2 3 1 1 2

158 2 1 1 2 3 4 2 3 3 3 2 4 1 3 1 2 2

159 2 2 1 2 3 3 2 2 2 3 3 3 2 3 2 2 2

160 2 2 2 2 3 3 3 2 3 3 2 3 2 2 1 2 2

161 2 1 1 1 2 3 2 2 2 3 3 4 2 3 2 2 2

Page 15: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 15 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

162 2 2 1 2 2 3 2 2 1 3 2 3 2 2 2 1 2

163 2 2 1 2 3 4 3 2 2 2 3 3 2 3 1 2 2

164 2 2 1 2 2 3 2 2 3 3 2 3 1 3 1 2 2

165 2 3 2 2 2 3 2 2 2 3 2 3 2 3 2 2 2

166 2 2 1 2 3 2 2 2 2 2 2 3 1 2 1 2 2

167 2 2 1 2 2 3 1 2 2 2 2 3 2 2 2 2 2

168 2 3 1 3 2 3 2 2 2 2 2 3 2 3 2 2 2

169 2 3 2 2 2 3 2 2 2 2 2 3 2 3 2 2 2

170 2 2 2 2 2 3 2 2 2 2 1 3 2 3 2 2 2

171 2 3 2 2 2 3 2 2 2 2 2 2 2 3 1 2 2

172 2 2 2 3 2 3 1 1 2 2 1 2 2 3 2 2 2

173 3 2 2 2 2 3 2 2 2 2 1 2 2 3 2 2 3

174 2 3 2 2 2 2 1 1 1 2 1 2 1 3 2 2 2

175 3 3 2 2 3 3 1 2 2 2 1 2 2 3 1 2 3

176 3 2 2 2 1 3 1 2 2 1 1 2 2 3 1 2 3

177 2 2 2 2 2 3 1 1 2 2 2 2 2 3 2 2 2

178 2 2 2 2 2 3 1 1 2 1 1 2 2 2 2 2 2

179 2 3 1 2 2 2 1 1 1 2 1 2 2 2 2 2 2

180 1 2 1 2 1 2 1 2 2 2 9 2 2 2 2 2 1

Page 16: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 16 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

Page 17: Test report of IES LM 79 08 Approved Method: …...Shenzhen Belling Efficiency Testing Lab Report No.: BL18010001-8 Shenzhen Belling Efficiency Testing Lab Tel:(86)755-29351191 Fax:(86)755-29351120

Page 17 of 017 Report No.: BL18010001-8

Shenzhen Belling Efficiency Testing Lab

Tel:(86)755-29351191 Fax:(86)755-29351120 www.bellingtest.com

Photo Document