test report - topololighttopololight.com/wp-content/uploads/2017/08/aio-tsl-isln-30w-iec... · test...

33
检测报告 TEST REPORT No.210106201600784 SAMPLESRoad and street lighting (Solar Powered LED Street Light) DATA(S) of TESTS2016-09-192016-10-26 MODEL/TYPETSL-ISLN-30 福建出入境检验检疫局检验检疫技术中心 INSPECTION AND QUARANTINE TECHNOLOGY CENTER OF FUJIAN ENTRY-EXIT INSPECTION AND QUARANTINE BUREAU(FJIQTC)

Upload: lynhu

Post on 30-May-2018

294 views

Category:

Documents


7 download

TRANSCRIPT

检测报告

TEST REPORT

No.: 210106201600784

SAMPLES: Road and street lighting (Solar Powered LED Street Light)

DATA(S) of TESTS: 2016-09-19~2016-10-26

MODEL/TYPE: TSL-ISLN-30

福建出入境检验检疫局检验检疫技术中心 INSPECTION AND QUARANTINE TECHNOLOGY CENTER OF FUJIAN

ENTRY-EXIT INSPECTION AND QUARANTINE BUREAU(FJIQTC)

Report No. :210106201600784 Page 1 of 32

TEST REPORT IEC 60598.1-2014

Luminaires Part 1: General requirements and tests

IEC 60598-2-3:2011

Luminaires Part 2-3: Particular requirements – Luminaires for road and street lighting

IEC 62031-2014

LED modules for general lighting – Safety specifications

Report Reference No….….….….: 210106201600784

Tested By………………….….…......: Zhang Xiaoquan Signature:

Checked By………….…….……......: Huang Huihua Signature:

Approved By……………….……….: Wu Zhenpeng Signature:

Date of issue…………….….........…: 2016-10-26

Laboratory ……………….…............. : Inspection & Quarantine Technology Center of Fujian Entry-exit

Inspection & Quarantine Bureau

Address……………….…….…..……: No.75, DongJiangbin Road, Mawei District, Fuzhou, China

P.C. ………………….…....……..…... : 350003

Tel……………………………………: 086-591-87065561

Fax……………………………..….....: 086-591-87065518

Testing Address…………….…..……: No.75, DongJiangbin Road, Mawei District, Fuzhou, China

Applicant’s name………….…….….: Zhejiang Inovus Science & Technology Co.,LTD

Address…………………..……….…: No.201 Weiwu Road ,Yueqing Economic Development Zone,

Wenzhou, Zhejiang

Standard…………….……...…...…..: IEC 60598-1: 2014 & IEC 60598-2-3:2011 & IEC 62031-2014

Explanation of deviation…..…….…..: —

Non-standard test method….....….…...: —

Trade Mark…………….…...….….….: Inovus Topolo

Model/Type reference…....…….…..: TSL-ISLN-30

Rating.…………………..……….…...: 12.8VDC 30W 2.34A

Manufacturer…………….…….….….: Zhejiang Inovus Science & Technology Co.,LTD

Address……….………..…..….….…: No.201 Weiwu Road ,Yueqing Economic Development Zone,

Wenzhou, Zhejiang

Date of samples received.…............….: 2016-09-19

Test Result………………….….….: PASS

Report No. :210106201600784 Page 2 of 32

General remarks:

1. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory.

2. The test results presented in this report relate only to the object tested.

3. All tests carry out only on the model TSL-ISLN-30 product.

Possible test case verdicts:

—Test case does not apply to the test object or is not carried out........….. : N

—Test object does meet the requirement ............…..…................….... : P(Pass)

—Test object does not meet the requirement .........................…......... : F(Fail)

Summary of test results (information/comments):

All tests are performed according to IEC 60598-1: 2014 & IEC 60598-2-3:2011 & IEC 62031-2014

Summary of testing: /

Difference between product under test and additional products

No. Model Battery Solar battery LED lamp beads Spec./Quantity

1 TSL-ISLN-15 10Ah/12.8V Max Power:28WP 0.1W/216pcs

2 TSL-ISLN-20 13Ah/12.8V Max Power:30WP 1W/20 pcs

3 TSL-ISLN-30 20Ah/12.8V Max Power:40WP 1W/30 pcs

Report No. :210106201600784 Page 3 of 32

Photo(s) of Sample

Nameplate

Appearance ( Front )

Appearance ( Back )

Report No. :210106201600784 Page 4 of 32

Photo(s) of Sample

Internal construction

Passive infrared sensor

Switch

Report No. :210106201600784 Page 5 of 32

Photo(s) of Sample

Solar charge controller

Battery

LED module

Report No. :210106201600784 Page 6 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

3.2(0) General TEST REQUIREMENTS

3.2(0.1) Scope and object

3.2(0.3) General requirements

3.2(0.4) General test requirements and verification

3.4(2) CLASSIFICATION

3.4(2.2) Type of protection (class 0 excluded) Ⅲ类

3.4(2.3) Degree of protection(Requirement: Ordinary) IP66

Luminaire suitable for direct mounting on normally flammable surfaces

Yes No

3.4(2.4) Luminaire not suitable for direct mounting on normally flammable surfaces

Yes No

Luminaires for normal use Yes No 3.4(2.5)

Luminaires for rough service Yes No

3.5(3) MARKING

Mandatory markings P

Position of the marking P 3.5(3.2)

Format of symbols/text P

Additional information P 3.5(3.3)

Language of instructions English P

The following information shall be provided:

a) design attitude P

b) weight including control gear if any 14.5kg P

c) overall dimensions 1165×310×75mm P

d) the maximum projected area subjected to wind force N

e) the range of cross-sectional areas of suspension wires N

f) suitability for use indoors provided the 10 °C, allowed for the effects of natural air movement, has not been deducted from measured temperature

N

g) dimensions of the compartment N

h) the torque setting to be applied to any bolts or screws 57 P

3.5(-)

i) maximum mounting height 5-6m P

3.5(3.3.1) Combination luminaires N

3.5(3.3.2) Nominal frequency in Hz N

3.5(3.3.3) Operating temperature N

Report No. :210106201600784 Page 7 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

3.5(3.3.4) Symbol or warning notice P

3.5(3.3.5) Wiring diagram N

3.5(3.3.6) Special conditions N

3.5(3.3.7) Metal halide lamps luminaire - warning N

3.5(3.3.8) Limitation for semi - luminaires N

3.5(3.3.9) Power factor and supply current 2.34A P

3.5(3.3.10) Suitability for use "indoors" including the related ambient temperature.

N

3.5(3.3.11) Luminaires with remote control N

3.5(3.3.12) Clip-mounted luminaires - warning N

3.5(3.3.13) Specifications of protective shields P

3.5(3.3.14) Symbol for nature of supply P

3.5(3.3.15) Rated current of socket outlet N

3.5(3.3.16) Rough service luminaire N

3.5(3.3.17) Mounting instruction for type Y, type Z and some type X attachments

N

3.5(3.3.18) Non-ordinary luminaires with PVC cable N

3.5(3.3.19) Protective conductor current N

3.5(3.3.20) Information - luminaires correct installation N

3.5(3.3.21) Information - instruction sheet P

3.5(3.3.22) For controllable luminaires the classification of insulation N

Test with water P

Test with petroleum P

Legible after test P 3.5(3.4)

Label attached P

3.6(4) CONSTRUCTION

At least IPX3 IP66 P

Tunnel-lighting luminaires, IPX5 is required. N

Glazing of column-integrated luminaires with an open - sided external part, IPX5 is required.

N

For column-integrated luminaires, the IP classification shall be as follows:

1) parts below 2,5 m: IP3X N

3.6.1(-)

2) parts above 2,5 m: IP2X N

3.6.2(-) Luminaires for suspension on span wires shall be fitted with clamping devices.

N

Report No. :210106201600784 Page 8 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

The clamping device shall prevent movement of the luminaire with respect to the span wire.

N

The suspension devices shall not damage the span wire. N

To withstand wind speeds of 150 km/h, without undue deflection

P

To prevent the dislodgement of any part of the luminaire P 3.6.3(-)

At least two devices. P

Static load test: P

- no visible failure impairing the safety P

- no permanent deformation from the attachment which exceeds a slope of more than 2 cm/m, and

P 3.6.3.1(-)

- no rotation around the point of attachment P

Adequate supporting device N 3.6.4(-)

Suitable reference marks N

3.6.5(-) The related requirements of glass cover. N

3.6.5.1(-) Protection by the use of glass that fractures into small pieces N

3.6.5.2(-) Protection by the use of high impact resistant glass N

Adequate space within the door opening. N 3.6.6(-)

Resistance to corrosion N

3.6.7(-) Column - integrated luminaires shall comply with ISO standards, or otherwise regional or national standards.

N

The door shall be treated against corrosion N

Authorized persons open the door only. N

1) the locking device shall still be operational N

2) no visible cracks shall be present on the sample N

3.6.8(-)

3) the level of IP protection shall not be reduced N

Cable entry slot shall be not less than 50 mm×150 mm N

No less than 50 mm from the slot to the connection compartment

N

Free from obstructions N

3.6.9(-)

No sharp edges, burrs, flashes etc N

3.6(4.2) Components replaceable without difficulty N

3.6(4.3) Wireways smooth and free from sharp edges N

3.6(4.4) Lampholders N

3.6(4.4.1) Integral lampholders N

3.6(4.4.2) Wiring connection N

Report No. :210106201600784 Page 9 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

3.6(4.4.3) Lampholder for end-to-end mounting N

Position: N

- pressure test (N) N

After test the lampholder comply with the relevant standard sheets and show no damage

N

After test on single-capped lampholder the lampholder have not moved from its position and show no permanent deformation

N

- bending test (Nm) N

3.6(4.4.4)

After test the lampholder have not moved from its position and show no permanent deformation

N

3.6(4.4.5) Peak pulse voltage N

3.6(4.4.6) Centre contact N

3.6(4.4.7) Parts in rough service luminaires resistant to tracking N

3.6(4.4.8) Lamp connectors N

3.6(4.4.9) Caps and bases correctly used N

3.6(4.4.10) Another way is not allowed. N

Starter holders: N

- starter holder in luminaires other than classⅡ N 3.6(4.5)

- starter holder class Ⅱconstruction. N

Terminal blocks N

Tails N 3.6(4.6)

Unsecured blocks N

3.6(4.7) Terminals and supply connections N

3.6(4.7.1) Contact to metal parts N

Test 8 mm live conductor N 3.6(4.7.2)

Test 8 mm earth conductor N

3.6(4.7.3) Terminals for supply conductors N

Welding connections: N

- stranded or solid conductor N

- spot welding N

- welding between wires N

- type Z attachment N

- mechanical test according to 15.8.2 N

- electrical test according to 15.9 N

3.6(4.7.3.1)

- heat test according to 15.9.2.3 and 15.9.2.4 N

Report No. :210106201600784 Page 10 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

3.6(4.7.4) Terminals other than supply connection N

3.6(4.7.5) Heat-resistant wiring/sleeves N

Multi-pole plug: N 3.6(4.7.6)

- test at 30 N N

Switches: P

- adequate rated P

- adequate fixing P

- polarized supply P

3.6(4.8)

- compliance with the IEC 61058-1 for electronic switches P

3.6(4.9) Insulating linings and sleeves N

Retainment N 3.6(4.9.1)

Method of fixing N

Insulating linings and sleeves N

Resistant to a temperature exceeding the temperature measured on the wire by 20 °C

N

a) & c) Insulation resistance and electric strength N

3.6(4.9.2)

b) Ageing test, Temperature (℃) N

3.6(4.10) Double and reinforced insulation N

No contact, mounting surfaces - accessible metal parts - wiring of basic insulation

N

Safe installation fixed luminaires N

Capacitors and switches N 3.6(4.10.1)

Interference suppression capacitors according to IEC 60384-14

N

Assembly gaps: N

- no coincidental N 3.6(4.10.2)

- no straight access with test probe N

Retainment of insulation: N

- fixed N

- unable to be replaced; luminaires inoperative N

- sleeves retained in position N

3.6(4.10.3)

- linings in lampholder N

3.6(4.11) Electrical connections P

3.6(4.11.1) Contact pressure N

Screws: N 3.6(4.11.2)

- self-tapping screws N

Report No. :210106201600784 Page 11 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

- thread-cutting screws N

- self-tapping screws may be used to provide earth continuity

N

Screw locking: N

- spring washer N 3.6(4.11.3)

- rivets N

3.6(4.11.4) Material of current-carrying parts P

3.6(4.11.5) No contact to wood or mounting surface N

3.6(4.11.6) Electro-mechanical contact systems No such systems N

3.6(4.12) Screws and connections(mechanical ) and glands P

Screws not made of soft metal P

Screws of insulating material N

Torque tests: torque (Nm); part 1.2,fixing screw of

LED modules P

Torque tests: torque (Nm); part 1.2,fixing screw of

battery P

3.6(4.12.1)

Torque tests: torque (Nm); part 1.2,fixing screw of solar charge controller

P

3.6(4.12.2) Screws with diameter less than 3 mm screwed into metal N

Locked connections: N

- fixed arms; torque (Nm) N

- lampholder; torque (Nm) N 3.6(4.12.4)

- push-button switches; torque 0.8 Nm N

3.6(4.12.5) Screwed glands; torque (Nm) N

3.6(4.13) Mechanical strength P

Impact tests: P

- fragile parts; energy (Nm) LED covers, 0.5 P

- other parts; energy (Nm) Enclosures, 0.7 P

1) live parts P

2) linings N

3) protection P

3.6(4.13.1)

4) covers No break P

3.6(4.13.2) Metal parts enclosing live parts shall have adequate mechanical strength

N

3.6(4.13.3) Straight test finger N

3.6(4.13.4) Rough service luminaires: N

Report No. :210106201600784 Page 12 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

- IP54 or higher N

a) fixed N

b) hand-held N

c) delivered with a stand N

d) for temporary installations and suitable for mounting on a stand

N

3.6(4.13.6) Tumbling barrel N

3.6(4.14) Suspensions and adjusting devices P

Mechanical load: P

A) four times the weight N

B) torque 2.5 Nm N

C) bracket arm; bending moment P

D) load track – mounted luminaires N

E) clip – mounted luminaires; glass – shelves.

Thickness (mm) N

3.6(4.14.1)

Metal rod; diameter (mm) N

Load to flexible cables N

Mass (kg) N

Stress in conductors (N/mm2) N

Mass (kg) of semi – luminaires N

3.6(4.14.2)

Bending moment (Nm) of semi – luminaires N

Adjusting devices: N

- flexing test; number of cycles N

- strands broken N 3.6(4.14.3)

- electric strength test afterwards N

3.6(4.14.4) Telescopic tubes: cords not fixed to tube; no strain on conductors

N

3.6(4.14.5) Guide pulleys N

3.6(4.14.6) Strain on socket-outlets. N

3.6(4.15) Flammable materials: P

- glow-wire test 650°C N

- spacing ≥ 30 mm. N

- screen withstanding test of 13.3.1 N

- screen dimensions N

3.6(4.15.1)

- no fiercely burning materials P

Report No. :210106201600784 Page 13 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

- thermal protection N

- electronic circuits exempted N

Luminaries made of thermoplastic materials with lamp control gear:

N

a) construction N

b) temperature sensing control N

3.6(4.15.2)

c) surface temperature N

Luminaires for mounting on normally flammable surfaces: P

- incorporating lamp control gear N 3.6(4.16)

- no lamp control gear P

Lamp control gear spacing: N

- spacing 35 mm N 3.6(4.16.1)

- spacing 10 mm N

Thermal protection: N

- in lamp control gear N

- external N

- fixed position N

3.6(4.16.2)

- temperature marked lamp control gear N

3.6(4.16.3) Design to satisfy the test of 12.6 N

Drain holes N 3.6(4.17)

Clearance at least 5 mm N

3.6(4.18) Resistance to corrosion P

3.6(4.18.1) Rust-resistance N

3.6(4.18.2) Season cracking in copper N

3.6 (4.18.3) Corrosion of aluminum P

3.6(4.19) Ignitors compatible with ballast N

3.6(4.20) Rough service vibration N

3.6(4.21) Protective shield N

Shield fitted N 3.6(4.21.1)

Shield of glass if tungsten halogen lamps N

3.6(4.21.2) Particles from a shattering lamp not impair safety N

3.6(4.21.3) No direct path N

Impact teat on shield N 3.6(4.21.4)

Glow-wire test on lamp compartment N

3.6(4.22) Attachments to lamps P

Report No. :210106201600784 Page 14 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

3.6(4.23) Semi – luminaires comply with class Ⅱ N

3.6(4.24) Photobiological hazards P

3.6(4.24.1) UV radiation for tungsten halogen lamps and metal halide lamps (Annex P)

N

3.6(4.24) Retinal blue light hazard P

3.6(4.24.1) UV radiation N

3.6(4.24.2) Retinal blue light hazard P

3.6(4.25) No sharp points or edges P

3.6(4.26) Short-circuit protection N

3.6(4.26.1) Uninsulated accessible SELV parts N

3.6(4.26.2) Short – circuit test N

3.6(4.26.3) Teat chain according to Figure 29 N

3.6(4.27) Terminal blocks with integrated screwless earthing contacts N

3.6(4.28) Fixing of thermal sensing controls N

3.6(4.29) Not to be replaced and/or to access live parts without breaking the luminaire or its parts.

P

protective cover N

symbol detailed by 3.2.24, N 3.6(4.30)

at least two independent fixings N

3.6(4.31) Insulation between circuits N

3.6(4.31.1) SELV circuits P

3.6(4.31.2) FELV circuits N

3.6(4.31.3) Other circuits N

3.6(4.32) Overvoltage protective devices N

REEPAGE DISTANCES AND CLEARANCES

Working voltage (V) 12.8VDC -

Voltage form Sinusoidal [ ]

Non-sinusoidal [ ] -

PTI <600[√] ≥600[ ] -

Pollution (Impulse) withstand category (Normal category II) (Category III Annex U)

Rated pulse peak voltage (kV) -

3.7(11)

1) Current - carrying parts of different polarity:

cr(mm); cl (mm)

between + and -: cr>1,5mm, cl>

1,5mm, required: cr: ≥1,2mm, cl ≥0,2mm

P

Report No. :210106201600784 Page 15 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

2) Current - carrying parts and accessible parts:

cr(mm); cl (mm)

cr>1,5mm, cl>1,5mm, required: cr: ≥1,2mm, cl ≥0,2mm

P

3) Parts becoming live due to breakdown of basic insulation and metal parts: cr(mm); cl (mm)

N

4) Outer surface of cable where it is clamped and metal parts: cr(mm); cl (mm)

N

5) Current - carrying parts of switches and metal parts: cr(mm); cl (mm)

N

6) Current - carrying parts and supporting surface: cr(mm); cl (mm)

cr>1,5mm, cl>1,5mm, required: cr: ≥1,2mm, cl ≥0,2mm

P

3.8(7) PROVISIONS FOR EARTHING

3.8.1(-) The attachment of the fixed part of the terminal shall prevent it from being rotated when the clamping part is moved.

N

Accessible metal parts N

Metal parts in contact with supporting surface N

Resistance < 0.5 Ω N

Self-tapping screws used N

Thread-forming screws N

Thread-forming screw used in a groove N

Earth makes contact first N

3.8(7.2.1+ 7.2.3)

Terminal blocks with integrated screwless earthing contacts, N

3.8(7.2.2+ 7.2.3)

Earth continuity in joints etc. N

Locking of clamping means N

Compliance with 4.7.3 N 3.8(7.2.4)

Terminal blocks with integrated screwless earthing contacts N

3.8(7.2.5) Earth terminal integral part of connector socket N

3.8(7.2.6) Earth terminal adjacent to mains terminals N

3.8(7.2.7) Electrolytic corrosion of the earth terminal N

Material of earth terminal N 3.8(7.2.8)

Contact surface bare metal N

Class II luminaire for looping-in N 3.8(7.2.10)

Double or reinforced insulation to functional earth N

Earthing core coloured green - yellow N 3.8(7.2.11)

Length of earth conductor N

Report No. :210106201600784 Page 16 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

SCREW TERMINALS

Separately approved; component list N 3.9(14)

Part of the luminaire See annex 3 N

3.9(-) Terminals for supply connection N

SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS

Separately approved; component list See annex 1 P 3.9(15)

Part of the luminaire See annex 4 N

3.10(5) INTERNAL AND EXTERNAL WIRING

3.10(5.2) Supply connection and other external wiring N

3.10(5.2.1) Means of connection N

Type of cable N 3.10(5.2.2)

Nominal cross-sectional area (mm²) N

3.10(5.2.3) Type of attachment, X, Y or Z N

3.10(5.2.5) Type Z not connected to screws N

Cable entries: N

- suitable for introduction N 3.10(5.2.6)

- adequate degree of protection N

3.10(5.2.7) Cable entries through rigid materials have rounded edges N

Insulating bushings: N

- suitably fixed N

- material in bushings N

- material not likely to deteriorate N

3.10(5.2.8)

- tubes or guards made of insulating material N

3.10(5.2.9) Locking of screwed bushing N

3.10.1(-) To provided a cord anchorage N

Cord anchorage: N

- covering protected from abrasion N

- clear how to be effective N

- no mechanical or thermal stress N

- no tying of cable into knots etc N

3.10(5.2.10)

- insulating material or lining N

Cord anchorages for type X attachment cord: N 3.10

(5.2.10.1) a) at least one part fixed N

Report No. :210106201600784 Page 17 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

b) types of cable N

c) no damaging of the cable N

d) whole cable can be mounted N

e) no touching of clamping screws N

f) metal screw not directly on cable N

g) replacement without special tool N

Glands not used as anchorage N

Labyrinth type anchorages N

3.10(5.2.10.2) Adequate cord anchorage for type Y and Z attachment N

Tests: N

- impossible to push the cable; unsafe N

- pull test: 25times, pull (N) N

- torque test: torque (Nm) N

- displacement ≤2 mm. N

- no movement of conductors N

3.10

(5.2.10.3)

- no damage of cable or cord N

3.10(5.2.11) External wiring passing into luminaire N

3.10(5.2.12) Looping - in terminals N

Wire ends not tinned N 3.10(5.2.13)

Wire ends tinned: no cold flow N

Mains plug same protection N 3.10(5.2.14)

Class Ⅲ luminaire plug N

Appliance inlets (IEC 60320) N 3.10(5.2.16)

Installation couplers(IEC 61535) N

3.10(5.2.17) Not standardized inter-connecting cables properly assembled

N

3.10(5.2.18) Used plug in accordance with IEC/TR 60083, or with regional or national standards

N

3.10(5.3) Internal wiring P

Internal wiring of suitable size and type P

Through wiring: N

- not delivered/mounting instruction N

- factory assembled N

- socket outlet loaded (A) N

3.10(5.3.1)

- temperatures N

Report No. :210106201600784 Page 18 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

Green and yellow combination for earth only N

Internal wiring connected directly to fixed wiring: N

- cross-sectional area (mm²) N

- insulation thickness N 3.10(5.3.1.1)

- extra insulation added where necessary N

Internal wiring connected to fixed wiring via internal current-limiting device

N 3.10(5.3.1.2)

Adequate cross-sectional area and insulation thickness N

3.10(5.3.1.3) Double or reinforced insulation for class II N

3.10(5.3.1.4) Conductors without insulation N

3.10(5.3.1.5) SELV current-carrying parts P

3.10(5.3.1.6) Insulation thickness other than PVC or rubber N

Sharp edges etc. P

No moving parts of switches etc. N

Joints, raising/lowering devices N

Telescopic tubes etc. N

3.10(5.3.2)

No twisting over 360° P

Insulating bushings: N

- suitable fixed N

- material in bushings N

- material not likely to deteriorate N

3.10(5.3.3)

Cables with protective sheath N

3.10(5.3.4) Joints and junctions effectively insulated N

3.10(5.3.5) Strain on internal wiring N

3.10(5.3.6) Wire carriers N

Wire ends not tinned N 3.10(5.3.7)

Wire ends tinned: no cold flow P

3.11(8) PROTECTION AGAINST ELECTRIC SHOCK

Live parts not accessible Ⅲ类 N

Basic insulated parts not used on the outer surface N

Lampholders and starterholders N

Protection in any position N

Tubular tungsten filament lamp N

3.11(8.2.1)

Insulation lacquer no reliable N

Report No. :210106201600784 Page 19 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

Double ended high pressure discharge lamp N

3.11(8.2.2) Portable luminaires adjusted in the most unfavourable position

N

Class Ⅱluminaires:

a) basic insulated metal parts not accessible during starter or lamp replacement

N

b) metal lamp holders for bayonet cap lamps in class I luminaires shall be earthed.

N

c) class III luminaires may have exposed current carrying parts in the SELV circuit

N

Class III luminaires are connected to an SELV source only. N

3.11(8.2.3)

PELV sources are not used at present for luminaires N

3.11(8.2.4) Portable luminaires shall have protection against electric shock which is independent of the supporting surface.

N

3.11(8.2.5) Compliance with the standard test finger or relevant test probe

N

3.11(8.2.6) Covers reliably secured N

Discharging of capacitor: ≥ 0.5 μF N

Portable plug connected luminaires with capacitor N

Other plug connected luminaires with capacitor N

Discharge device on or within capacitor N

3.11(8.2.7)

Discharge device mounted separately N

3.12(12) ENDURANCE TEST AND THERMAL TEST

Endurance test: P

- mounting-position Normal position -

- test temperature (℃) 55℃ -

- total duration (h) 240 h -

- supply voltage: Un factor; calculated voltage (V) 14.1 V -

3.12(12.3)

- lamp used LED -

After endurance test: -

- no part unserviceable P

- plastic ES lampholders shall not be deformed N

- luminaire not unsafe P

- no damage to track system N

3.12(12.3.2)

- marking legible P

Report No. :210106201600784 Page 20 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

- no cracks, scorches and deformation P

3.13(9) RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE

Tests for ingress of dust, solid objects and moisture: P

- classification according to IP IP66 -

- mounting position during test Normal position -

- fixing screws tightened; torque (Nm) -

- tests according to clauses (9.2.0) -

- electric strength test afterwards P

a) no deposit of talcum powder - dust-proof luminaires N

b) no deposit of talcum powder inside - enclosures dust-tight luminaires

P

c) no trace of water on electrical connections, carrying parts or or on insulation where it could become a hazard

P

c) 1) for luminaires without drain holes - no water entry P

c) 2) for luminaires with drain holes - no hazardous water entry

N

d) no water in watertight luminaire N

e) no contact with live parts (IP2X) N

e) no entry into enclosure (IP3X and IP4X) N

f) no trace of water in any part of a lamp P

3.13(9.2)

g) no damage on protective shield or glass envelope N

3.12(12.4) Thermal test (normal operation) See annex 2 P

3.12(12.5) Thermal test (abnormal operation) N

3.12.3(-) Glass covers shall be used within the thermal limits declared by the glass manufac-turer.

N

3.12(12.6) Thermal test (failed lamp control gear condition) N

Luminaires without thermal cut-out N

Through wiring or looping-in wiring loaded by a current of ( A ):

N

- case of abnormal conditions N

- electronic lamp control gear N

- measured winding temperature (℃): at 1.1 Un N

- measured mounting surface temperature (℃): at 1.1 Un N

3.12(12.6.1)

- calculated mounting surface temperature (℃) N

Report No. :210106201600784 Page 21 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

- track – mounted luminaires N

Temperature sensing control: N

- case of abnormal conditions N

- thermal link N

- manual reset cut-out N

- auto reset cut-out N

- measured mounting surface temperature(℃) N

3.12(12.6.2)

- track – mounted luminaires N

3.12(12.7) Thermal test (failed lamp control gear in plastic luminaires):

N

Luminaires without temperature sensing control: N

- case of abnormal conditions N

- measured winding temperature (℃) at 1.1 Un N

- measured temperature of fixing point/exposed part (℃) at 1.1 Un

N

3.12(12.7.1)

- calculated temperature of fixing point/exposed part (℃) N

Luminaires with temperature sensing control: N

- thermal link N

- manual reset cut-out N

- auto reset cut – out N

- case of abnormal conditions

3.12(12.7.2)

- highest measured temperature of fixing point/exposed part (℃)

N

3.13(9.3) Humidity test 48 h 25℃ 93%RH P

3.14(10) INSULATION RESISTANCE AND ELECTRIC STRENGTH

3.14(10.2) Insulation resistance and electric strength P

Insulation resistance test P

Cable or cord covered by metal foil or replaced by a metal rod of mm Ø

SELV: DC 100V 1min P

- between current-carrying parts of different polarity N

- between current-carrying parts and mounting surface >100MΩ P

3.14(10.2.1)

- between current-carrying parts and metal parts of the luminaire

>100MΩ P

Report No. :210106201600784 Page 22 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts

N

- insulating bushings N

Other than SELV: N

- between live parts of different polarity N

- between live parts and the mounting surface N

- between live parts and metal parts of luminaire N

- between live parts of different polarity through action of a switch

N

- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts

N

- insulating bushings N

Electric strength test P

Dummy lamp N

Luminaires with ignitors after 24 h test N

Luminaires with manual ignitors N

SELV: 500V, 50Hz 1min

- between current-carrying parts of different polarity N

- between current-carrying parts and mounting surface P

- between current-carrying parts and metal parts of the luminaire

P

- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts

N

- insulating bushings N

Other than SELV:

- between live parts of different polarity N

- between live parts and the mounting surface N

- between live parts and metal parts of luminaire N

- between live parts of different polarity through action of a switch

N

- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts

N

- insulating bushings N

3.14(10.2.2)

No flashover or breakdown P

3.14(10.3) Leakage current (mA) N

3.15(13) RESISTANCE TO HEAT, FIRE AND TRACKING

Report No. :210106201600784 Page 23 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

3.15(13.2) Resistance to heat P

Ball - pressure test: P

- part tested; temperature (℃) Switch, 125 P 3.15(13.2.1)

- part tested; temperature (℃) Connector, 125 P

3.15(13.3) Resistance to flame and ignition P

Needle-flame test P

- part tested Switch P 3.15(13.3.1)

- part tested Connector P

3.15(13.3.2) Glow-wire test 650℃ N

3.15(13.4.1) Tracking test; part tested N

ANNEX 1: components

Part name Manufacturer/

trademark Type/model

Technical data

Standard Mark(s) of conformity

Solar Controller

Shenzhen Shuori New Energy Technology

Co., Ltd SR-SES60 12V/24V 10A

EN61000-6-3 EN61000-6-1

T185072601

Solar Cell module

Shenzhen Zhong Jin Solar Co., Ltd

SNM-M26 SNM-M30 SNM-40

Power/Volt:26W/18V

30W/18V 40W/18V

IEC/EN61215 IEC/EN61730-1 IEC/EN61730-2

/

LED boar

Goldenmax International

Technology(Zhuhai) LTD

GF432 V-0 130℃ UL796 UL E330731

LED

XUYU OPTOELECTRONICS(SHENZHEN)CO.,LT

D

XY-1W Power:1W

CCT:6000K White light

EN55015 EN61547

CE

C185015101

Switch

ZHEJIANG ONPOW PUSH BUTTON

MANUFACTURE CO.,LTD

GQ16 48VDC/AC 2A

EN 61058-1 CE

VT11018807

Battery Shenzhen Yinkai Power

Battery Co., Ltd LiFePO4 26650 10Ah/12.8V TSL-ISLN-15 /

Battery Shenzhen Yinkai Power

Battery Co., Ltd LiFePO4 26650 13Ah/12.8V TSL-ISLN-20 /

Battery Shenzhen Yinkai Power

Battery Co., Ltd LiFePO4 18650 20Ah/12.8V TSL-ISLN-30 /

Report No. :210106201600784 Page 24 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

ANNEX 2: temperature measurement, thermal tests of Section 12 P

Type reference TSL-ISLN-30

Lamp used LED

Lamp control gear used

Mounting position of luminaire Normal position

Supply wattage (W) 30

Supply current (A) 2.34

Calculated power factor -

Table: measured temperatures correct for ta = 45℃-10℃

- abnormal operation mode

- test 1: rated voltage -

- test 2: 1.06 times rated voltage or 1.05 times rated wattage 13.6V

- test 3: Load on wiring to socket-outlet, 1.06 times voltage or 1.05 times wattage

- test 4: 1.1 times rated voltage or 1.05 times rated wattage

clause 12.4 - normal clause 12.5 - abnormal Temperature (℃) of part

test 1 test 2 test 3 limits test 4 limits

Internal wire - 47.1 - 90 - -

Switch - 46.2 - 55 - -

ANNEX 3: screw terminals (part of the luminaire) N

(14) SCREW TERMINALS

Type of terminal - (14.2)

Rated current (A) -

(14.3.2.1) One or more conductors N

(14.3.2.2) Special preparation N

Terminal size N (14.3.2.3)

Cross-sectional area (mm²) N

(14.3.3) Conductor space (mm) N

(14.4) Mechanical tests N

(14.4.1) Minimum distance N

(14.4.2) Cannot slip out N

Report No. :210106201600784 Page 25 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

(14.4.3) Special preparation N

Nominal diameter of thread (metric ISO thread) N

External wiring N (14.4.4)

No soft metal N

(14.4.5) Corrosion N

Nominal diameter of thread (mm) N (14.4.6)

Torque (Nm) N

Between metal surfaces N

Lug terminal N

Mantle terminal N (14.4.7)

Pull test; pull (N) N

(14.4.8) Without undue damage N

ANNEX 4: screwless terminals (part of the luminaire) N

(15) SCREWLESS TERMINALS

Type of terminal N (15.2)

Rated current (A) N

(15.3.1) Material N

(15.3.2) Clamping N

(15.3.3) Stop N

(15.3.4) Unprepared conductors N

(15.3.5) Pressure on insulating material N

(15.3.6) Clear connection method N

(15.3.7) Clamping independently N

(15.3.8) Fixed in position N

Conductor size N (15.3.10)

Type of conductor N

(15.5.1) Terminals internal wiring N

(15.5.1.1) Pull test spring-type terminals (4 N, 4 samples) N

Pull test pin or tab terminals (4 N, 4 samples) N (15.5.1.2)

Insertion force not exceeding 50 N N

(15.5.2) Permanent connections: pull-off test (20 N) N

Electrical tests N (15.6)

Voltage drop (mV) after 1 h (4 samples) N

Report No. :210106201600784 Page 26 of 32

IEC 60598-2-3:2011 & IEC 60598-1: 2014

Clause Contents and Requirements Results-Explanations Verdict

Voltage drop of two inseparable joints N

Number of cycles N

Voltage drop (mV) after 10th alt. 25th cycle (4 samples) N

Voltage drop (mV) after 50th alt. 100th cycle

(4 samples) N

After ageing, voltage drop (mV) after 10th alt. 25th cycle

(4 samples) N

After ageing, voltage drop (mV) after 50th alt.

100th cycle (4 samples) N

Terminals external wiring N (15.7)

Terminal size and rating N

Pull test spring-type terminals or welded connections

(4 samples); pull (N) N

(15.8.1) Pull test pin or tab terminals (4 samples);

pull (N) N

Contact resistance test N (15.9)

Voltage drop (mV) after 1 h N

Report No. :210106201600784 Page 27 of 32

IEC 62031:2008

Clause Contents and Requirements Results-Explanations Verdict

Classification:

– built-in Yes No -

– independent Yes No - 6

– integral Yes No -

7 Marking

Mandatory markings(other than integral controlgear):

- mark of origin N

- model number, type reference N

- either

rated supply voltage(s), or voltage range, supply frequency or/and

N

rated supply current(s) or current range, supply frequency or/and

N

rated input power, or power range. N

- nominal power N

- indication of position and purpose of the connections N

- value of tc N

- for eye protection N

7.1

- built-in modules shall be marked in order to separate them from independent modules

N

7.2 Location of marking N

Durability and legibility of marking: N 7.3

- rubbing 15s with water N

Terminals

Screw terminals: compliance with Section 14 of IEC 60598.1.

N

Screwless terminals: compliance with Section 15 of IEC 60598.1.

N

8

Connectors, compliance with IEC 60838-2-2, if applicable N

9 Provisions for protective earthing

External metal parts connected to the earthing terminal N

Terminal complying with clause 8 of Part 1 N 9(IEC61347-1

) Locked against loosening and not possible to loosen by hand N

Report No. :210106201600784 Page 28 of 32

IEC 62031:2008

Clause Contents and Requirements Results-Explanations Verdict

Not possible to loosen clamping means unintentionally on screwless terminals

N

Earthing via means of fixing N

Earthing terminal only used for the earthing of the lamp controlgear

N

All parts of material minimizing the danger of electrolytic corrosion

N

Made of brass or equivalent material N

Contact surface bare metal. N

Conductors by tracks on printed circuit boards: N

- a.c. current of 25 A for 1min between earthing terminal and accessible metal parts

N

- compliance with clause 7.2.3 in IEC 60598.1 N

10 Protection against accidental contact with live parts

Controlgear protected against accidental contact with live parts

SELV circuit N

Integral lamp controlgear N

Lacquer or enamel not used for protection or insulation N

Adequate mechanical strength on parts providing protection N

10.1(IEC61347-1)

Not removed without use of a tool N

10.2(IEC61347-1)

Capacitance >0.5 μF: voltage after 1 min <50V N

11 Moisture resistance and insulation

After storage 48 h at 91% - 95% relative humidity and 20°C - 30 °C measuring of insulation resistance with d.c. 500 V

25°C,93%RH

≥2 MΩ for basic insulation. >100MΩ P 11(IEC61347-

1)

≥4 MΩ for reinforced insulation between live parts and the body.

N

12 Electric strength

Immediately after clause 11 electric strength test for 1 min P

Working voltage ≤ 42V, test voltage 500V P

42V<working voltage ≤1000V, test voltage:

- reinforced insulation, 4U+2750 N

12(IEC61347-1)

No flashover or breakdown P

Report No. :210106201600784 Page 29 of 32

IEC 62031:2008

Clause Contents and Requirements Results-Explanations Verdict

13 Fault conditions

Overpower condition: P

- no fire, smoke or flammable gas is produced P 13.2

-15 min overpower condition has been withstood P

When operated under fault conditions, the controlgear:

- does not emit flames or molten material N

- does not produce flammable gases N

- protection against accidental contact not impaired N

14.1(IEC61347-1)

Thermally protected controlgear does not exceed the marked temperature value

N

14.2(IEC61347-1)

Short circuit of creepage distances and clearances N

14.3(IEC61347-1)

Short circuit across or interruption of semi-conductor devices

N

14.4(IEC61347-1)

Short circuit across insulation consisting of lacquer, enamel or textile

N

14.5(IEC61347-1)

Short circuit across electrolytic capacitors N

Insulation resistance≥1MΩ N

No flammable gases N 14.6(IEC6134

7-1)

Accessible parts have not become live N

Construction

Wood, cotton, silk, paper and similar fibrous material: P 15

- not used as insulation P

16 Creepage distances and clearances

Creepage distances and clearances according to Tables 3 and 4, as appropriate

See annex 5 P 16(IEC61347-1)

Insulating lining of metal enclosures N

Screws, current-carrying parts and connections

17 Screws, current-carrying parts and mechanical connections in compliance with IEC 60598.1(clause numbers between parentheses refer to IEC 60598.1)

N

(4.11) Electrical connections and current-carrying parts N

(4.11.1) Contact pressure N

Report No. :210106201600784 Page 30 of 32

IEC 62031:2008

Clause Contents and Requirements Results-Explanations Verdict

Screws: N

- self-tapping screws N

- thread-cutting screws N (4.11.2)

- at least two self-tapping N

Screw locking: N

- spring washer N (4.11.3)

- rivets N

(4.11.4) Material of current-carrying parts N

(4.11.5) Not contact to wood N

(4.11.6) Electro-mechanical contact systems N

(4.12) Mechanical connections and glands N

Mechanical stresses N

Screws not made of soft metal N

Screws of insulating material N (4.12.1)

Torque test: part; a torque (Nm) N

(4.12.2) Screws diameter<3mm screwed into metal. N

(4.12.4) Locked connections N

(4.12.5) Screwed glands: force(N) N

18 Resistance to heat, fire and tracking

Parts of insulating material either retaining live parts in position or providing protection against electric shock, ball-pressure test:

N 18.1

- part; test temperature(℃) N

18.2 Resistance to flame and ignition N

18.3 Glow-wire test 650°C N

18.4 Needle-flame test N

18.5 Tracking test N

19 Resistance to corrosion

Rust protection N

- test according to 4.18.1 of IEC 60598-1. N 19(IEC61347-

1)

- adequate varnish on the outer surfaces. N

21 Heat management

Report No. :210106201600784 Page 31 of 32

IEC 62031:2008

Clause Contents and Requirements Results-Explanations Verdict

21.1 General non-exchangeable N

21.2 Heat-conducting foil and paste N

21.3 Heat protection (under consideration) N

21.4 Construction N

22 Photobiological safety

UV radiation:

22.1 - the ultraviolet hazard efficacy of luminous radiation of an LED module shall not exceed 2 mW/klm.

N

Blue light hazard:

22.2 - the blue light hazard shall be assessed according to IEC TR 62778.

P

22.3 Infrared radiation: N

Report No. :210106201600784 Page 32 of 32

IEC 62031:2008

Clause Contents and Requirements Results-Explanations Verdict

ANNEX 5: TABLE: creepage distances and clearances P

Minimum distances for a.c. (50/60 Hz) sinusoidal voltages

RMS working voltage(V) not exceeding 50 150 250 500 750 1000

1 minimum distances between live parts of different polarity. Specify the value measured.(creepage distances/clearances)

1.5/1.5

2 minimum distances between live parts and accessible metal parts which are permanently fixed to the lamp controlgear, including screws or devices for fixing covers or fixing the lamp controlgear to its support. Specify the value measured.(creepage distances/clearances)

3 minimum distances for ballasts declared not to rely on the luminaire enclosure for protection against electric shock – between live parts and the outer accessible surface of insulating parts. Specify the value measured(creepage distances/clearances)

- required creepage distances(mm), insulation PTI ≥ 600

0,6 1,4 1,7 3 4 5,5

- required creepage distances(mm), insulation PTI < 600

1.2 1,6 2,5 5 8 10

- required clearances 0,2 1,4 1,7 3 4 5,5

4 minimum distances between live parts and a flat supporting surface or a loose metal cover, if any, if the construction does not ensure that the values under 2 above are maintained under the most unfavourable circumstances

– required clearances 2 3,2 3,6 4,8 6 8

Minimum distances for non-sinusoidal pulse voltages

rated pulse voltage (peak kV) 2,0 2,5 3,0 4,0 5,0 6,0 8,0 10 12

required minimum clearance (mm) 1,0 1,5 2 3 4 5,5 8 11 14

Specify the value measured

rated pulse voltage (peak kV) 15 20 25 30 40 50 60 80 100

required minimum clearance (mm) 18 25 33 40 60 75 90 130 170

Specify the value measured

The following space is blank