testcellmanager - fev › fileadmin › user_upload › media › ... · testcellmanager/e/...

2
www.fev.com CONTACT FEV GmbH Neuenhofstraße 181 52078 Aachen, Germany phone +49 241 5689 -0 fax +49 241 5689 -119 e-mail [email protected] SOFTWARE AND TESTING SOLUTIONS TestCellManager/E/SOFTWARE AND TESTING SOLUTIONS/2016 The automation of test sequences and the data acquisition increases significantly the quality of the results and the utilisation of test equipment. In order to meet this challenge, FEV has developed the TestCellManager (TCM) as a product. FEV TCM TestCellManager is the central operating, control and observation software for the individual test bench. Due to its modular design the TCM offers flexibility and ease of extension. Software modules with clearly defined functionality allow generating tailor made solutions to the respective requirements. The use of Microsoft Windows as user interface and a real time system (RTX) allow a high quality measurement data chain. Modern familiar software strategies and designs ensure simple operation of the extensive functions. The TCM is responsible for the execution of automated, semi- automated or manually controlled test sequences. Functions » Manual and automated test bench operation » Test procedure automation » Test procedure visualization » Data acquisition and logging » Limit Monitoring » Data processing » Live data and status visualization » Device control and coordination Automation and Data Acquisition TestCellManager

Upload: others

Post on 01-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TestCellManager - FEV › fileadmin › user_upload › Media › ... · TestCellManager/E/ SOFTWARE AND TESTING SOLUTIONS /2016 The automation of test sequences and the data acquisition

www.fev.com

CONTACTFEV GmbHNeuenhofstraße 18152078 Aachen, Germanyphone +49 241 5689 -0fax +49 241 5689 -119 e-mail [email protected]

SOFTWARE AND TESTING SOLUTIONS

Test

CellM

anag

er/E

/SOF

TWAR

E AN

D TE

STIN

G SO

LUTI

ONS/

2016

The automation of test sequences and the data acquisition increases significantly the quality of the results and the utilisation of test equipment. In order to meet this challenge, FEV has developed the TestCellManager (TCM) as a product.

FEV TCM TestCellManager is the central operating, control and observation software for the individual test bench.Due to its modular design the TCM offers flexibility and ease of extension. Software modules with clearly defined functionality allow generating tailor made solutions to the respective requirements.

The use of Microsoft Windows as user interface and a real time system (RTX) allow a high quality measurement data chain. Modern familiar software strategies and designs ensure simple operation of the extensive functions. The TCM is responsible for the execution of automated, semi-automated or manually controlled test sequences.

Functions» Manual and automated test bench operation» Test procedure automation» Test procedure visualization» Data acquisition and logging » Limit Monitoring» Data processing» Live data and status visualization» Device control and coordination

Automation and Data Acquisition

TestCellManager

Page 2: TestCellManager - FEV › fileadmin › user_upload › Media › ... · TestCellManager/E/ SOFTWARE AND TESTING SOLUTIONS /2016 The automation of test sequences and the data acquisition

www.fev.com

SOFTWARE AND TESTING SOLUTIONS

Automation and Data Acquisition

TestCellManager

One automation for all test bench variantsCombustion Engines | E-Machines | Battery | Transmission | Hybrid drivetrain concepts | Powertrain

Technical dataComputer type | Display 19-inch 4HU Industrial PC (always the latest model) | 2 x 24-inch TFT

Operating system Windows 7 / RTX 2012

Inputs / outputs Interface for analogue measuring equipment, CAN, CANopen, CANRaw

Measuring equipment EtherCAT, Ethernet, serial different protocols e.g. AK, CANopen, CANRaw

ECU Interface ASAM-MCD3 (ASAP3) series or TCP/IP, KWP 2000, SAE J1939

Other interfaces AK server, ASAM-ACI, FEV CAS, TCP/IP proprietary…

TxM -Interface TCM signal interface via EtherCAT or Replicator (TCP/IP)

All-in-one» One product applicable for all test benches, test runs and test objects, even expandable by user

» Easy familiarization, allows easy transfer from one task to the other

Fast performance in real-time

» Fully integrated execution of MATLAB/Simulink models (Model Handler)» Fieldbus crosslinking with EtherCAT » 1kHz logging of minimum 128 channels

Flexibility

» Easy integration of new test bench devices and actuators (Device Driver), expandable by user via proper scripting language

» Extensive library of devices available » 2 different namespaces can be independently chosen for user screens and logged data

Usability» Flowchart-based definition of tests (Test Scheduler) » Full-text search with autocomplete and intelligent filtering » Easy navigation via definition of favorite screens and

Future-proof» Modular framework allows tailor-made configurations » Open & scalable architecture allows future enhancements » Downward compatibility of future versions

Data acquisitionAll channels connected to the system can be recorded with respect to statistical characteristic values, such as average, minimum and maximum values or standard deviation, both continuously and at configurable time intervals.

Sequential control Set point value profiles for all connected channels for automated control Free programming of sequences via the embedded script language

Limit value monitoringSetting limits to avoid undesirable operating conditions and to react on limit violationsParallel history logs to document the process events before and after the overshoot of one or more limits

Online calculations of characteristics

Online calculation of characteristics make it possible to look at, react to or record calculated characteristics even during the test itself

Device control Numerous interfaces for the integration of special measuring instruments, as well as communication with a control unit application system

Our performance - your benefit

Main functions