testing 02

3
 Shutdown SIS Previous Screen  Product: NO EQUIPMENT SELECTED Model: NO EQUIPMENT SELECTED Configuration: NO EQUIPMENT SELECTED Testing and Adjusting VR6 Voltage Regulator Media Number -RENR2480-04 Publication Date -01/12/2007 Date Updated -17/12/2007 i02655741 Voltage - Adjust SMCS - 4467-025 Illustration 1 g00779323  Page 1 of 3 Media Search - RENR2480 - VR6 Voltage Regulator 10/8/2010 https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe ...

Upload: steve-da-rivia

Post on 04-Nov-2015

5 views

Category:

Documents


0 download

DESCRIPTION

Testing

TRANSCRIPT

  • Shutdown SIS

    Previous Screen

    Product: NO EQUIPMENT SELECTED

    Model: NO EQUIPMENT SELECTED

    Configuration: NO EQUIPMENT SELECTED

    Testing and Adjusting VR6 Voltage Regulator Media Number -RENR2480-04 Publication Date -01/12/2007 Date Updated -17/12/2007

    i02655741

    Voltage - Adjust

    SMCS - 4467-025

    Illustration 1 g00779323

    Page 1 of 3Media Search - RENR2480 - VR6 Voltage Regulator

    10/8/2010https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe...

  • VR6 Voltage Regulator

    (1) Voltage adjustment

    Illustration 2 g01021519

    The Cat VR6 presents an electrical shock/electrocution hazard. This hazard will cause serious injury or death.

    Service by trained personnel only.

    The terminals and heat sinks are live at hazardous voltages when power is applied and for up to 8 minutes after power is removed.

    Rotate the voltage adjustment (1) in the clockwise direction in order to increase the voltage. Rotate the voltage adjustment (1) in the counterclockwise direction in order to decrease the voltage.

    When the jumper is installed between terminals 4 and 7, the nominal voltage of the generator can be varied over the operating range by using the voltage adjustment (1) .

    In order to use an external voltage adjust potentiometer, perform the following procedure:

    Stop the genset.1.

    Page 2 of 3Media Search - RENR2480 - VR6 Voltage Regulator

    10/8/2010https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe...

  • Remove the jumper between terminals 4 and 7.2.

    Connect an external voltage adjust potentiometer across terminals 6A and 7. The potentiometer should be rated at 10 K Ohm.

    3.

    Note: On some gensets, the voltage adjust potentiometer is located on the control panel.

    Turn the voltage adjustment (1) on the regulator in a fully clockwise direction in order for the external adjustment to operate properly.

    4.

    Copyright 1993 - 2010 Caterpillar Inc.

    All Rights Reserved.

    Private Network For SIS Licensees.

    Fri Oct 8 19:01:47 EST 2010

    Page 3 of 3Media Search - RENR2480 - VR6 Voltage Regulator

    10/8/2010https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe...