testpoint portfolio - d3fdwrtpsinh7j.cloudfront.netthe jdsu testpoint ts-10 chassis provides a fixed...
TRANSCRIPT
TestPoint PortfolioDetailed Version
2
TestPoint offers a flexible and cost-effective telecom and datacom test solution for Production and Service Verification Testing (SVT). It consists of a modular platform that provides versatility in configuring interface types, transmission rates, protocols, and port density.A key TestPoint attribute is support for multiple rates on single modules. The platform also features an easy-to-use graphical user interface (GUI) and simple automation interfaces. It is available in three chassis formats: a lightweight, fixed interface TS-10; a 3-slot TS-30; and a 17-slot TS-170. TestPoint provides 1/2/4/8/10 G Fibre Channel (FC) support and Ethernet features from 10 Mb/s up to 10 Gigabit Ethernet (GigE). Transport protocol coverage includes synchronous optical network technologies/synchronous digital hierarchy (SONET/SDH) up to 39.813 Gb/s, and Optical Transport Network (G.709) up to 43.018 Gb/s including overclocked rates 11.049 Gb/s,11.095 Gb/s,11.270 Gb/s and 11.317 Gb/s.
Table of Contents Page
TestPoint TS-chassis (TS-10,TS-30, and TS-170) 3
TestPoint 40Gbps V2 5
TestPoint 10Gbps 8
TestPoint 1Gbps 16
TestPoint Multi-Rate 21
TestPoint Group Controller 29
3
TestPoint TS-chassis (TS-10,TS-30, and TS-170)
Key Features The TestPoint chassis support hot swappability and a •high level of independence for all modules
The TestPoint chassis provide scalability and high port •density
Control of TestPoint equipment is achieved over a web •browser and Java plug-in removing the need to install PC software
TestPoint supports simple and robust automation•
The JDSU TestPoint TS-10 chassis provides a fixed interface configuration and is a lightweight, easy-to-carry platform equipped with a handle.
The JDSU TestPoint TS-30 and TS-170 are slot-based chassis equipped with modules. The TS-30 can be configured for rack mounting or portability with a handle and bumpers.
All modules in the TS-30 and TS-170 support hot insertion and removal.
Modules and configurations, including available options, are:
10Gbps (TS-10, TS-30, and TS-170) −
1Gbps (TS-10, TS-30, and TS-170) −
40Gbps (TS-30 and TS-170) −
Multi-Rate (TS-10, TS-30, and TS-170) −
Group Controller (TS-30 and TS-170)s −
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS
4
SYSTEMConnectivity and GUI
Requires PC and 10/100BASE-T LAN connection. Static IP and DHCP (dynamic IP) supportLAN management port supports simple network time protocol (SNTP)GUI interface via web browser and Java plug-in. No PC software requiredTS-30/170: PC connects to modules via the Group Controller (one LAN cable) or directly to each module’s faceplateTS-30/170:Group Controller supports multiple concurrent users
Automation
Via Command Line Interface (CLI) ASCII commands.Connection to CLI via Telnet, socket connections, or serial portAutomation toolkits available in: Python / C / TCL / LabView / Visual Basic
Management Functions
GUI installation tool provided for field software upgradesEach module has non-volatile storage for: software loads /configuration files / event logs / test results / capture filesResult files (event logs / test results / RFC 2544 results) can be automatically transferred to the controlling PCTS-30/170:Group Controller module provides external clock-ing ports:T1 / E1 / GPS (including 10MHz) / and other rates
CHASSISThe TS-10 provides a fixed interface configuration. The TS-30 and TS-170 are slot-based and all modules support hot insertion and removal.
TS-10The TS-10 is a lightweight, easy to carry platform equipped with a handle.
Chassis specificationsHeight 5.6 cm; 2.25 inches Depth 42.5 cm; 17 inchesWidth 35 cm; 14 inches Width 3.7 kg; 8.1 lbsOperating temperature 0-35°C Operating humidity 0-85%
TS-30The TS-30 provides three slots. It either comes with a rackmount kit or a handle and bumpers. The Group Controller module or any test module may use slot 0.
Chassis specificationsHeight 8.75 cm; 3.5 inches Depth 37.5 cm; 15 inches
Width 42.5 cm; 17 inches Width 7.7 kg; 17 lbs
Operating temperature 0-35°C Operating humidity 0-85%
TS-170The TS-170 provides seventeen slots. Test modules may occupy sixteen slots, slot 0 is reserved for the optional Group Controller module. The TS-170 comes with a rackmount kit.
Chassis specificationsHeight 26.25 cm; 10.5 inches Depth 52.5 cm; 21 inches
Width 42.5 cm; 17 inches Width 22.7 kg; 50 lbs
Operating temperature 0-35°C Operating humidity 0-85%
ORDER INFORMATION
TS-170 N550-0090 TS-170 17-slot chassis
TS-30N550-0100 TS-30 3-slot chassis- commercial versionN550-0101 TS-30 3-slot chassis-industrial versionOPT 0100-03 19-inch rack-mount kit for TS-30OPT 0100-04 Rubber bumpers and transport handle kit for TS-30 chassis
AccessoriesOPT 0100-10 Wheeled hard travel case accepting TS-30 or TS-10 chassisN470-002 Filler modules for TS-30/TS-170 chassis
TESTPOINT TS-CHASSIS (TS-10, TS-30, AND TS-170)
5
High density solution for 40G testing
Channelized OC-768 / STM-256 (down to STS-192 / •VC-4-64c)
OTU3 (43.018 Gbps) with SONET/SDH or Bulk PRBS •client
PRBS framed and unframed•
Clock rate variations•
Reporting of incoming optical power and clock offset•
G.828 / G.829 Performance Monitoring•
Service Disruption Time for both OTU3 and SONET / •SDH
Intrusive and transparent monitor connectivity modes•
The TestPoint 40Gbps V2 two-slot module fits into both the TS-30 chassis and the TS-170 chassis. Channelized SONET / SDH testing is provided as standard functionality at OC-768 / STM-256 down to STS-192c / VC-4-64c. Traffic consists of a pseudo random binary sequence (PRBS) pattern.
The 40Gbps V2 Module also offers an option for Digital Wrapper and forward error correction (FEC) support at OTU3 (43.018 Gbps).
Up to eight 40Gbps V2 Modules can be inserted into a TS-170 chassis providing the industry’s most dense and scalable 40G testing environment. Inserted into the TS-30 chassis the 40Gbps V2 Module provides a very compact solution.
With its multiple chassis options and comprehensive feature set, the 40Gbps V2 Module is a cost-effective and flexible test platform. Highlights of the 40Gbps V2 Module feature set include:
Best in class Service Disruption Time Measurements –
Extensive alarm and error insertion and monitoring –
Robust and straightforward automation and scripting –
Easy-to-use graphical user interface (GUI) –
TestPoint 40Gbps V2
Highlights
Applications
SONET/SDH: OC-768 / STM-256 –
Digital Wrapper and FEC: OTU3 (ITU-T –G.709)
Compliance
CSA Certificate of Compliance to CAN/ –CSA C22.2 No. 60950-1 (2003) and ANSI / UL 60950-1 (2003) with CSA Mark for Canada and USA
CSA CB Certificate of Compliance to –EN60950-1, IEC 60950-1 and National Deviations with CE Marking
Class 1 Laser Product, with compliance to –EN 60825, IEC 60825 and FDA / CDRH requirements
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS
6
OPTICALReceive power measurementTransmit laser on / off
LINE RATESReports PPM offset on receive interface39.813 Gbps (SONET / SDH)43.018 Gbps (OTU3)
CLOCKINGInternal (± 4.6 ppm accuracy)Recovered from lineExternal via group controller (TS-30 / 170)Clock rate variations ± -30 ppmClock output
LOGGINGEvent log
Log injections
CONNECTIVITYTerminal: Source and sink trafficTransparent monitor: Transparently monitors signal and retransmits unalteredIntrusive monitor: Can inject layer 1 errors and pass traffic unaltered
APPLICATIONS
Descriptions of the applications:
SONET / SDHOC-768: STS-786c / STS-192cSTM-256:VC-4-256c / VC-4-64c
DIGITAL WRAPPER AND FECOTU3 (ITU-T G.709): Client can be PRBS or SONET/SDH BERT
UNFRAMED39.813 Gbps43.018 Gbps
SONET/SDH
ALARMS
LOS / LOF / OOF / AIS-L / MS-AIS / RDI-L / MS-RDI / LOP-P /AU-LOP / AIS-P / AU-AIS / RDI-P / HP-RDI / UNEQ-P / HP-UNEQ / ERDI-P
ERRORSSingle / Rates for LOF / AIS-L / RDI-L / ERDI / REI-L / MS-REI / REI-P / HP-REI / B1 / B2 / B3 / PayloadDuration (in ms) for LOS / [AIS-L/MS-AIS] / [RDI-L/MS-RDI]
ENLARGED VIEW OF ERRORS & ALARMS REPORT
Up to 4 indicators of errors and alarms detected by the TestPoint. Object of each indicator can be chosen by user from the above list of alarms and errors.
OVERHEADSPointer adjustments: Increment / Decrement (single, rates) / NDF count / Pointer value / SS bitsTrace messages: J0 / J1; 1, 16 or 64 bytesDecoded bytes: K1 / K2 / S1 / C2Byte diagram: User editable overhead fields (includes B1, B2, B3 xor masks) in two alternating overhead banks. Interleaving and injection counts in frames / continuous injection support
TRAFFICPRBS 7 / 11 / 15 / 23 / 31 / 4-byte sequence / 16-byte sequence / pattern invert
PERFORMANCE MONITORING (G.828/G.829) For Section / Regenerator section (near-end) and line / mul-tiplex section (near-end; far-end): ES, ESR, SES, SESR, BBE, BBER, UASFor Path (near-end; far-end): ES, ESR, SES, SESR, BBE, BBER, SEP, SEPI, UAS, VerdictThreshold configuration
TEST REPORTContains performance monitoring settings and statistics
SIGNALFramed / unframed (raw pattern) at 39.813 Gbps
INTERFACE SPECIFICATIONS
Fixed OpticsOptical connector LCWavelength 1550 nmOptical output power (Rx power read) 0 to +3 dBmOptical overload (min) +3 dBmSensitivity (min) -6 dBmClock out LVPECL signal, AC coupled on SMA connectorLAN (Ethernet) Port RJ 45 (10/100BASE-T)Operator port RJ 12 into RS-232 serial cable
TESTPOINT 40GBPS V2
7
OTU3 DIGITAL WRAPPER AND FEC
ALARMSLOS / OOF / LOF / OOM / LOM / OTU-AIS (PN-11) / OTU-IAE / OTU-BDI / OTU-BIAE / ODU-AIS (PM / TCM1-6) / ODU-LCK (PM / TCM1-6) / ODU-OCI (PM / TCM1-6) / ODU-BDI (PM / TCM1-6) / ODU-BIAE (TCM1-6)
ERRORSSingle and rate for OUT-BIP8 / OTU-BEI / ODU PM & TCM1-6 BIP8 / ODU-BEI (PM / TCM1-6) / Payload
OVERHEADSMulti frame structuresOTU-TTI / ODU-TTI (PM / TCM1-6) / ODU-FTFL / PSIOverhead message editor and viewer
Justification events: Sync (line-client locked) on transmit with PRBS client, client frequency offsetError suppression: To optionally suppress incoming errors / alarms: FEC / PM errors
CLIENTSSONET / SDH as described in SONET / SDH sectionBulk PRBS 7 / 11/ 15 / 23 / 31 / 4-byte sequence / 16-byte sequence / pattern invert
FECSettings: Standard FEC / All-zeroes FEC. Enable / disable error correctionInjection: Single. Control of errored sub-row (includ-ing all) / errored bytes per sub-row / errored bits per byte / skipped rows between errors. Up to 16 symbol errorsDetection: Number of correctable byte errors / number of correctable bit errors / bit error rate / number of uncorrectable sub-rows
SIGNALFramed / unframed (raw pattern) at 43.018 Gbps
SERVICE DISRUPTION TIMEMeasurement: µs resolutionStatistics: Current / Previous / Minimum / Maximum / Average / CountEvent loggingAutomatic re-triggeringTriggers:SONET/SDH: LOS / LOF / PRBS Sync / AIS-L/MS-AIS / AIS-P/AU-AIS / OOF / RDI-L/MS-RDI / RDI-P/AU-RDI / B1 / B2 / B3OTU3: LOS / AIS / LOF / LOM / OOF / OOM / SM-BDI / SM-BIP8 / ODU-AIS / ODU-LCK / ODU-OCI / PM-BDI / PM-BIP8 / PRBS Sync
ORDER INFORMATION
N530-0292 40Gbps V2 Module with NRZ optics and SONET/SDH
N530-0292-UNF 40Gbps V2 Module with NRZ optics and unframed only
OptionsOPT 0290-02 OTN 43G G.709 Digital Wrapper / FEC
AccessoriesOPT 0100-10 Wheeled hard travel case accepting TS-10
or TS-30 chassis
TESTPOINT 40GBPS V2
8
TestPoint 10Gbps
Highlights
Applications
Facilitates both 10 Gbps line and client –testing
Tests Ethernet and Fibre Channel trans- –port
Provides 8.5-11.3 Gbps traffic blasting –
Compliance
CSA Certificate of Compliance to CAN / –CSA C22.2 No. 60950-1 (2003) and ANSI / UL 60950-1 (2003) with CSA Mark for Canada and USA
CSA CB Certificate of Compliance to –EN60950-1,IEC 60950-1, and National Deviations with CE Marking
Class 1 Laser Product in compliance with –EN 60825, IEC 60825, and FDA / CDRH requirement
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS
Automatic testing with minimum script development time
Tests all 10G related rates with one module – 10 GigE •LAN and WAN, 8G and 10G Fibre Channel
Comprehensively supports OTN-related rates – ODU2, •OTU2, 11.049G, 11.095G, 11.270G, and 11.317G
Supports EFEC (ITU-T G.975.1 I.4)•
Maps GFP-F directly into OTU2 and SONET / SDH •(STS-192c / VC-4-64c)
Maps 10GigE LAN with preambles into OTU2 using •GFP-F into extended payload (ITU-T G.Sup.43 7.3)
Runs framed and unframed PRBS at all supported rates•
Captures MAC traffic and line codes (64B / 66B for •10 GigE, 8B / 10B for 8GFC)
Edits and plays back 64B / 66B 10 GigE PCS codes •
Generates up to 4096 unique traffic streams in ExStreams •mode (MAC / stacked VLAN, MPLS, IPv4, IPv6)
The TestPoint 10Gbps Module supports a comprehensive set of line rates and protocols in the 10 Gbps range. Its applications include the testing of 10 Gigabit Ethernet (LAN / WAN) and SONET / SDH. Also offered are licensed options for 8 & 10 Gigabit Fibre Channel (8/10GFC), several Generic Framing Procedure (GFP) flavours, and Cisco high level data link control (HDLC)
A factory installed hardware option provides forward error correction (FEC) and Enhanced FEC (EFEC) support at the following rates: ODU2 (10.037 Gbps), OTU2 (10.709 Gbps), OTU1e (11.049 Gbps) , OTU2e (11.095 Gbps) , OTU1f (11.270 Gbps) , and OTU2f (11.317 Gbps). The test interface uses a 10 Gigabit small form-factor pluggable (XFP) socket which supports optical and electrical connectivity options.
The 10Gbps module can be inserted into multiple scalable chassis options, including the highly compact TS-10 configuration. Additional highlights of the 10 Gbps module include a strong focus on lower-layer testing and an RFC 2544 test suite for 10 GigE and 8 / 10GFC.
Note: The TestPoint 10Gbps is available as a module for multi-slot systems (TestPoint TS-30 and TS-170) or in a static, self-contained configuration (TestPoint TS-10). The term module is used in this document.
9
TESTPOINT 10GBPS
INTERFACE SPECIFICATIONS
Optical XFPOptical connector LC LC LCWavelength 850 nm 1310 nm 1550 nmOptical output power (Rx power read)
–4 to –1.1 dBm –6 to –1 dBm –1 to +2 dBm
Optical overload (min) –1 dBm 0.5 dBm 2 dBmSensitivity (min) –11.1 dBm –11 dBm –13.5 dBmDifferential Electrical XFPConnector NoteImpedance single-ended 50 OhmCable length 14 inchesType SMATransmitterMinimum single-ended amplitude 150 mVMaximum single-ended amplitude 385 mV Level set to low
560 mV Level set to highReceiverSensitivity with PRBS23 @BER1012 (single-ended peak-to-peak)
100 mV Optimized RX equalizer
Clock OutputOutput level LVPECL, AC coupledConnector SMA/50 OhmManagement Ports10/100Base-T LAN (Ethernet) via RJ45Operator port via RJ12 into RS-232 serial cableLAN management port Supports simple network time protocol
(SNTP) configurable for static IP address or DHCP
OPTICAL
Receive power measurementTransmit laser on / offXFP information display
ELECTRICAL
Receive equalization settingTransmit level high/low
LINE RATES
Reports PPM offset on receive interface8.500 G (8GFC)9.953 Gbps (10GigE WAN and OC-192 / STM-64 BERT)10.037 Gbps (ODU2)10.3125 Gbps (10 GigE LAN)10.51875 Gbps (10GFC)10.709 Gbps (OTU2)11.049 Gbps (OTU1e, 10 GigE LAN with FEC, no fixed stuff bytes)11.095 Gbps (OTU2e, 10 GigE LAN with FEC, with fixed stuff bytes)11.270 Gbps (OTU1f, 10GFC with FEC, no fixed stuff bytes)11.317 Gbps (OTU2f, 10GFC with FEC, with fixed stuff bytes)
CLOCKING
Internal (± 4.6 ppm accuracy)Recovered from lineExternal via group controller (TS-30 / 170)Clock rate variations ± 30 ppm: 10 GigE WAN, SONET / SDH, OTU2± 110 ppm: 10 GigE LAN, 8 / 10GFC, 11.X G ratesClock output
LOGGING
Event log
Log injections
CONNECTIVITY
Transparent monitor: Transparently monitors signal and retransmits unaltered (all supported line rates)Intrusive monitor: Can inject layer 1 errors and pass traffic unaltered (OTN related rates, SONET / SDH)Logical loopback: Used to switch MAC and IP addresses to loop traffic back (10 GigE LAN)
TerminalIntrusive Monitor
Logical Loopback
APPLICATIONS
Description of the applications:
10 GigE10 GigE LAN: 10 GigE directly on the line10 GigE WAN: 10 GigE into SONET / SDH
SONET / SDHOC-192 / STM-64 (channelized down to STS-1 / VC-3)
DIGITAL WRAPPER & FECODU2: OTU2 frame structure without FECOTU2: Client can be PRBS, 10 GigE WAN, SONET / SDH BERT or GFP11.049G FEC: PRBS or 10 GigE LAN client, frame structure without fixed stuff bytes 11.095G FEC: PRBS or 10 GigE LAN client, frame structure with fixed stuff bytes11.270G FEC: PRBS or 10GFC client, frame structure without fixed stuff bytes11.317G FEC: PRBS or 10GFC client, frame structure with fixed stuff bytes
FIBRE CHANNEL
8G and 10GPoint-to-point
GFP-FAll GFP-F modes feature a LAN clientGFP-F directly in OPU2GFP-F in OC-192/STM-64 (STS-192c / VC-4-64c)GFP-F in OC-192/STM-64 STM-64 wrapped in OTU2GFP-F into ODU2 extended payload (ITU-T G.Sup43 7.3)
GFP-TGFP-T wth 8GFC client directly in OPU2
cHDLCCisco HDLC in OC-192 / STM-64 (STS-192c / VC-4-64c); or in OC-192 / STM-64 wrapped in OTU2
UNFRAMEDPRBS and user pattern on all supported line rates
10 GigE
Description covers 10 GigE LAN and WAN
TRAFFIC SETTINGSFour modes: Single stream, multiple streams (physical ports), multiple streams (logical ports ExStreams), PCS play from bufferTestPoint allows for full bi-directional traffic testing
10
SINGLE STREAMUsed for BERT testing at PCS, MAC, single / stacked VLAN, and IPv4 layers
Send mode: Continuous / burst of framesProtocol support: MAC / single / stacked VLAN / LLC / SNAP / IPv4User can set header values. For destination / source MAC addresses and VLAN IDs, support of single / incrementing value over a rangeFrame size: Range of 19 to 65,535 bytes. Size can be: fixed / incrementing / decrementing / random / user sequence (up to 8)Transmission rate: Specified as bandwidth (%,Mbps , frame/s) or number of inter frame gap (IFG) bytes (fixed / random / sequence up to 8; range 8 to 16,777,215 bytes)Frame payload: PRBS 15, 23, or 31 / 16-byte sequence / pat-tern invert
MULTIPLE STREAMSUsed for traffic simulation and multi-protocol support
Maximum number of streams: 128 for physical ports / 4096 for logical ports (ExStreams) Number of logical ports (ExStreams): User setting to 1, 2, 4, 8, 16 or 32. Per transmit port, up to 4096/[# of logical ports] streams can be defined. Each receive port can detect up to 4096 streamsSend mode: Continuous / burst of framesProtocol support: MAC / single / stacked VLAN / MPLS / IPv4 / IPv6 / TCP (logical port) / UDP (logical port). User can set header values per streamFrame size: Range of 27 to 9,600 bytes. Size can be: Fixed / random within a streamTransmission rate: BW % / IFG size in bytes / frames/sAuto-scale BW: Scales bandwidth when total exceeds 100%Frame payload: Fill byte / random / custom (user defined byte-by-byte)Stream signature: Used for receive auto-detection
PCS PLAY FROM BUFFERUsed to edit PCS blocks, inject detailed errors, and create cus-tom low-level patternsSend mode: Continuous / buffer burst
Protocol support: Raw blocks / PCS / MACPCS editing: Load from PCS capture file (auto-delineates MAC frames) / manual from scratchAuto-validation: Sync header bits / PCS block type value / SOF and EOF mismatch / MAC CRC / control codesAuto-correction: MAC CRCFile type: Binary / ASCII
CONTROL PLANEPause frames: Single / continuous with interval. Pause timerReceiver throttlesARP: ARP request sent for each unique des tination IP address; Timeout, Retry Period and Count supportARP Reply sent on port MAC address match Gateway and Subnet Mask Settings
PINGSend mode: Continuous / packet countTransmission period: 1,000 to 4,294,967,295 msProtocol support: IPv4 with no VLAN / single / stacked VLANData size: 0 to 9,554 bytesReplies: Issued on port IP address match
ERROR INJECTIONSPCS sublayer: LOS / Remote Fault / Local Fault / error control character / user-defined 64B / 66B block (single, rates) / sync header error (single, HI BER, loss of sync) / 64B / 66B block type error (single, rates)
SINGLE STREAMMAC: CRC single, error rate
MULTIPLE STREAMSApplies to physical ports and logical ports (ExStreams) modes Applied to a specific streamMAC: CRC count / sequence number error (lost, out of order, duplicate) count
ERROR MONITORINGPCS sublayer: LOS / PCS synchronization / HI BER / Remote Fault / Local Fault / invalid 64B / 66B blocks / sync header errors / error control characters / Rx_E state
MAC sublayer: Frames too long (>jumbo) / Jabbers / under-sized / fragments / CRC errors / in-range length errors (802.3 frames) / short IFGs (adjustable threshold)IPv4: Checksum errors
STATISTICSMAC: Bandwidth (%, Mbps , frames/s) / frame count / octet count / unicast frames / multicast frames / broadcast frames / [single / stacked VLAN tagged frames] / number of pause frames / ARP frames / MPLS tagged frames / frame length bins (including jumbo) / CRC counts (total and length bins) / short preamble count / long preamble countMPLS: Frame countIPv4: Packet count / ICMP packetsIPv6: Packet count / ICMP packetsPer stream statistics: Valid frames / valid bytes / frame rate (fps) / BW in % / BW in Mbps / MAC CRC error count / frames lost (count, ratio) / frames duplicated / frames out of order
In logical ports multiple streams (ExStreams), a linked error summary is provided
TESTPOINT 10GBPS
11
LATENCY AND SEQUENCINGIn single stream modeSequencing: Frame loss / out-of-order / duplicates. Can inject errors on transmitTimestamping: Latency (min, max, avg over test period and 0.5 s window; bit forwarding / store and forward) / packet jitter
One-way latency measurements available across module in a chassis; requires group controller
FILTERSMAC: 8 MAC / VLAN filters with accept / discard operationPattern filter: Up to 6 bytes with offset from start of frame
CAPTURES
Two modes: 64B / 66B PCS, and MAC level
PCSTriggers: Manual / PCS sync loss / invalid 64B / 66B block / sync header error / Remote Fault / Local Fault / control code match / block type field match / data pattern match (up to 8 bytes)
Trigger point: Start / middle / endDisplay: Trigger point / 64B / 66B blocks as in Figure 49-7 IEEE 802.3ae-2005Size: 3,355,400 64B / 66B blocksFile type: Binary / ASCII
MACTriggers: Manual / CRC error / undersized frame / frame too long / in-range length error
Trigger point: Start / middle / endFilters: MAC filters / pattern filterDisplay: Trigger point / timestamp / MAC layer decodeSize: 400,000 frames / 32.4 Mbytes / full frame or slicing (first 64 bytes)File type: Binary (snoop compatible with Wireshark)
RFC 2544
Provides throughput, latency, frame loss, and back-to-back measurements in single stream mode. Up to 10 frame sizes Supports function to run all tests in succession. Logs results to file and generates graphics
TEST REPORT
Contains 10 GigE settings, errors, and statistics
OPTICAL TEST PATTERNSSquare wave: Programmable between 4 and 11 bitsPseudo-random (AnAiBnBi- LF, AnAiBnBi-zero, AnAiAnAi-zero, BnBiBnBi-LF) Transmit and receive with PCS sync header and block error countsPRBS31: Transmit and receive with bit error injection and bit error count
SONET / SDH
CHANNELIZATIONOC-192: STS-192c / STS-48c / STS-12c / STS-3c / STS-1STM-64: VC-4-64c / VC-4-16c / VC-4-4c / VC-4 / VC-3 (AU-3)
ALARMS
LOS / LOF / OOF / [AIS-L / MS-AIS] / [RDI-L / MS-RDI] / [LOP-P / AU-LOP] / [AIS-P / AU-AIS] / [ERDI-P / HP-ERDI] / [UNEQ-P / HP-UNEQ]
ERRORSSingle / rates for LOF / [AIS-L / MS-AIS] / [RDI-L / MS-RDI] / [REI-L / MS-REI] / [REI-P / HP-REI] / B1 / B2 / B3Duration (in ms) for LOF / [AIS-L / MS-AIS] / [RDI-L / MS-RDI]
OVERHEADSPointer adjustments: Increment / decrement (single, rates) / NDF count / pointer values / SS bitsTrace messages: J0 / J1; 1, 16 or 64 bytesDecoded bytes: K1 / K2 / S1 / C2Byte diagram: User editable overhead fields (includes B1,B2, B3 xor masks) in two alternating overhead banks. Interleaving and injection counts in frames / continuous injection support
PERFORMANCE MONITORING
(G.828 / G.829)
Available except for 10 GigE WANFor section / Regenerator section (near-end) and line / mul-tiplex section (near-end; far-end): ES, ESR, SES, SESR, BBE, BBER, UASFor path (near-end; far-end): ES, ESR, SES, SESR, BBE, BBER, SEP, SEPI, UAS, VerdictThreshold configuration
TRAFFIC10 GigE client (10 GigE WAN) / PRBS 15, 23 or 31 / 4-byte sequence / GFP-F / cHDLC
DIGITAL WRAPPER AND FEC
For both GFEC and EFEC I.4 EFEC is as per ITU-T G.975.1 I.4 Description covers ODU2, OTU2,11.049G FEC, 11.095G FEC, 11.270G FEC and 11.317G FEC. GFEC and EFEC does not apply to ODU2
ALARMS
LOS / OOF / LOF / OOM / LOM / OTU-AIS (PN-11) / OTU-IAE / OTU-BDI / OTU-BIAE / ODU-AIS (PM / TCM1-6) / ODU-LCK (PM / TCM1-6) / ODU-OCI (PM / TCM1-6) / ODU-BDI (PM / TCM1-6) / ODU-BIAE(TCM1-6)
TESTPOINT 10GBPS
12
ERRORSSingle and rates for OTU-BIP8 / OTU-BEI / ODU-BIP8 (PM / TCM1-6) / ODU-BEI (PM / TCM1-6)
OVERHEADSMulti-frame structure: OTU-TTI / ODU-TTI (PM / TCM1-6) / FTFL / PSIJustification events: Sync (line-client locked) / async (range ± 70 ppm). Reporting of justification event ratio and line-client ppm offsetByte diagram: User editable overhead fields / MFAS invert Injection count in frames / continuous injectionOverhead PRBS: 3 independent PRBS 15 engines for GCC0-2 / RES (OTU, ODU, OPU) / TCM1-6 / TCM ACT / EXPError suppression: to optionally suppress incoming errors / alarms: FEC / TCM1-6 errors / PM errors / client errors
CAPTURES
Triggers: Manual / OOF / LOF / OOM / LOM / OTU-IAE / OTU-BDI / OTU-BIAE / OTU-BIP8 / OTU-BEI / ODU-AIS (PM / TCM1-6) / ODU-LCK (PM / TCM1-6) / ODU-OCI (PM / TCM1-6) / ODU-BDI (PM / TCM1-6) / ODU-BIP8 (PM / TCM1-6) / ODU-BEI (PM / TCM1-6) / ODU-BIAE ( TCM1-6) / positive justification / nega-tive justification / overhead PRBS bit error / pattern match (equal, not equal) with bit-maskPattern match fields: FAS / MFAS / GCC0-2 / OTU RES / SM TTI / ODU RES1-3 / (TCM / ACT) / FTFL / EXP / (APS / PCC) / TCM1-6 TTI / PM TTI / OPU RES1-3Trigger point: Start / middle / endDisplay: Trigger point / Hex values for all overhead fieldsSize: Overhead of 256 framesFile type: ASCII (csv)
CLIENTSOTU2: PRBS 9, 15, 23, or 31 / 4-byte sequence / pattern invert / 10 GigE WAN / (SONET / SDH BERT) / GFP-F / GFP-TODU2: PRBS 9, 15, 23, or 31 / 4-byte sequence / pattern invert / (SONET / SDH)11.049 G / 11.095G: 10 GigE LAN11.270 G / 11.317 G: 10GFC
GFEC (G.709) and EFEC I.4 (G.975.1)Settings: GFEC / EFEC / all-zeroes FEC selectable. Enable / dis-able error correction
Injection: Single and rates. Control of errored sub-row (includ-ing all) / errored bytes per sub-row / errored bits per byte / skipped rows between errors. Up to 16 symbol errorsDetection: Number of correctable byte errors / number of cor-rectable bit errors / bit error ratio / number of uncorrectable sub-rows
8G FIBRE CHANNEL
8GFC point-to-point mode is described here
TRAFFIC SETTINGS
Send mode: Continuous / burst of frames Frame size: Range of 12 to 4,104 bytes (multiple of 4, includes SOF & EOF). Size can be: Fixed / incrementing / decrementing / random / user sequence (up to 8)Transmission rate: Specified as bandwidth (%, Mbps , frames/s) / number of inter frame gap (IFG) bytes (fixed / random / sequence up to 8; range 8 to 65,535 bytes)FC-2 framing: User can set 24-byte header valuesClass support: Class 3Flow control: Manual buffer-to-buffer credit setting; range 1 to 4,095. Sending of R_RDY may be enabled / disabledFrame payload: PRBS 15, 23 or 31 / 16-byte sequence / pat-tern invert
LINK INITIALIZATIONSettings: Enable / disable. LF1 / LF2 state forceReporting: Active state indicator / LF1 report / LF2 report / Primitive sequence protocol error count / loss of sync count / link failure count
ERROR INJECTIONSPCS sublayer: LOS / running disparity error (single, rates) / [8B / 10B coding error (single, rates)] / random bit corruption (single, rates)FC-1: Misaligned frames (non-multiple of 4 bytes size)FC-2: CRC (single, rates)
ERROR MONITORING
PCS sublayer: LOS / synchronization / running disparity errors / invalid 8B / 10B Code groups / short IFGs (adjustable threshold)FC-1: Frames oversized (>2148 bytes) / frames undersized (<36 bytes) / frames misaligned (non-multiple of 4 bytes)FC-2: CRC errors
STATISTICS
FC-1: Bandwidth (%,Mbps , frames/s) / frame count / octet count / number of R_RDY
LATENCY AND SEQUENCING
Sequencing: Frame loss / out-of-order / duplicates. Can inject errors on transmitTimestamping: Latency (min, max, avg over test period and 0.5 s window) / packet jitter. One-way latency measurements available across all modules in a chassis; requires group controller
CAPTURES
Captures 8B / 10B codesTriggers : Manual / sync loss / invalid 8B / 10B code group / running disparity error / code group pattern match (up to 6 bytes)Trigger point: Start / middle / endDisplay: Trigger point / 8B / 10B code group and decode (D / K codes and hex)Size: 8,250,000 code groupsFile type: Binary / ASCII
RFC 2544
Functionality as described under 10 GigE
TEST REPORT
Contains settings, errors, and statistics
OPTICAL TEST PATTERNSTransmits JSPAT, JTSPAT with receive BER measurement
10G FIBRE CHANNEL
10GFC point-to-point mode is described here
TRAFFIC SETTINGS
Send mode: Continuous / burst of framesFrame size: Range of 12 to 4,104 bytes (multiple of 4, includes SOF & EOF). Size can be: Fixed / incrementing / decrementing / random / user sequence (up to 8)Transmission rate: Specified as bandwidth (%, Mbps , frames/s) / number of inter frame gap (IFG) Bytes (fixed / random / sequence up to 8; range 8 to 65,535 bytes)FC-2 framing: User can set 24-byte header valuesClass support: Class 3Flow control: Manual buffer-to-buffer credit setting; range 1 to 4,095. Sending of R_RDY may be enabled / disabledFrame payload: PRBS 15, 23 or 31 / 16-byte sequence / pat-tern invert
TESTPOINT 10GBPS
13
LINK INITIALIZATIONSettings: Enable / Disable. LF1 / LF2 state forceReporting: Active sate indicator / LF1 / LF2 / primitive sequence protocol error count / loss of sync count / link failure count
ERROR INJECTIONSPCS sublayer: LOS / Remote Fault / Local Fault / error control character / user-defined 64B / 66B block (single, rates) / sync header error (single, HI BER, loss of sync) / 64B / 66B block type error (single, rates)FC-1: Misaligned frames (non-multiple of 4 bytes size)FC-2: CRC (single, rates)
ERROR MONITORING
PCS sublayer: LOS / PCS synchronization / HI BER / Remote Fault / Local Fault / invalid 64B / 66B blocks / sync header errors / error control characters / RX_E state / short IFGs (adjustable threshold)FC-1 frames oversized (>2148 bytes) / frames undersized (<36 bytes) / frames misaligned (non-multiple of 4 bytes)FC-2: CRC errors
STATISTICSFC-1: Bandwidth (%, Mbps , frames/s) / frame count / octet count / number of R_RDY
LATENCY AND SEQUENCINGSequencing: Frame loss / out-of-order / duplicates. Can inject errors on transmit Timestamping: Latency (min, max, avg over test period and 0.5 s window) / packet jitter. One-way latency measurements available across all modules in a chassis; requires group controller
CAPTURESCaptures 64B / 66B codesTriggers: Manual / PCS sync loss / invalid 64B / 66B block / sync header error / Remote Fault / Local Fault / control code pattern match / block type field match / block pattern match (up to 8 bytes)Trigger point: Start / middle / endDisplay: Trigger point / 64B / 66B blocks as in figure 49-7 IEEE 802.3-2005Size: 3,355,400 64B / 66B blocksFile type: Binary / ASCII
RFC 2544
Functionality as described under 10 GigE
TEST REPORT
Contains FC settings, errors, and statistics
OPTICAL TEST PATTERNSSquare wave: Programmable between 4 and 11 bitsPseudo-random: AnAiBnBi- LF, AnAiBnBi- Zero, AnAiAnAi-zero, BnBiBnBi-LF : Transmit and receive with PCS Sync header and block error countsPRBS31: Transmit and receive with bit error injection and bit error count
GFP-F
There are three possible mappings for GFP-F: as direct OTU2 client ; in OC-192 / STM-64 (STS-192c / VC-4 64c); or in OC-192 / STM-64 wrapped in OTU2
TRAFFIC SETTINGS
Send mode: Continuous / burst of framesHeader settings: PLI (auto-calculate on / off) / PTI / EXI / UPI / pFCS (on / off) / linear extension header (on / off) / channel ID / spare cHEC error correction on / off on receiveProtocol support: MAC / single / stacked VLAN. User can set header valuesScrambler: Core header scrambler (enable / disable); payload header scramble(enable / disable)Frame size: Range of 33 to 65,535 bytes (GFP frame). Size can be: Fixed / incrementing / decrementing / randomTransmission rate: Specified as bandwidth (Mbps ) / number of GFP Idle frames (fixed / random; range 0 to 65, 535 bytes)Frame payload: PRBS 15, 23, or 31 / 4-byte sequence / pattern invert
ERROR INJECTIONSGFP: Loss of client signal (LCS) / loss of client character syn-chronization (LCCS) / short GPF frame / pFCS (single, rates) / Idle GFP frame (single, 16-bit x or mask) / core header (single, rates; 16-bit x or mask) / type header (single, rates; 16-bit x or mask) / Extension header (single, rates; 16-bit x or mask)MAC: CRC (single, rates)
ERROR MONITORING
GFP: Loss of frame delineation (LFD) / LCS count / LCCS count / short GFP frames / undefined fields (client signal Fail, PTI, EXI) / pFCS errors / single-bit cHEC errors / multi-bit cHEC errors / single-bit tHEC errors / multi-Bit tHEC errors / single-bit eHEC errors / multi-Bit eHEC errorsMAC: Frames too long (>jumbo) / Jabbers / undersized / Fragments / CRC errors / in-range length errors (802.3 frames)
STATISTICSGFP: Bandwidth (Mbps , % frames/s) / frame count / octet count / management frame count / GFP Idle frame count MAC: Frame count / octet count / unicast frames / multicast frames / broadcast frames / single / stacked VLAN tagged frames / frame length Bins (including jumbo) / CRC counts (total and lengths bins)
FILTERSMAC: 8 MAC / VLAN filters with accept / discard operationPattern filter: Up to 6 bytes with offset from start of GFP frame
CAPTURES
Triggers: Manual / LFD / single-bit cHEC error / multi-bit cHEC error / tHEC error / eHEC error / pFCS error / management frame / large GFP frame (with threshold) / MAC CRC errorTrigger point: Start / middle / endFilters: Exclude Idle frame (on / off)Display: Trigger point / Timestamp / GFP and MAC layer decode Size: 700,000 frames / 32.4 Mbytes / full frame or slicing (first 64 bytes)File type: Binary (Snoop) / ASCII
GFP-F with Preambles (G.Sup43 7.3)
Maps 10GigE LAN with preambles into extended ODU2 payload as per ITU-T G.Sup43 7.3
TRAFFIC SETTINGSSend mode: Continuous / burst of framesHeader settings: PTI / UPIProtocol support: MAC / single / stacked VLAN. User can set header valuesScrambler: Core header scrambler (enable / disable); payload header scramble(enable / disable)Frame size: Range of 35 to 10,240 bytes (GFP frame). Size can be: Fixed / incrementing / decrementing / randomTransmission rate: Specified as bandwidth (Mbps, fps) Frame payload: PRBS 15, 23, or 31 / 16-byte sequence / pat-tern invert
ERROR INJECTIONSGFP: Loss of client signal (LCS) / loss of client character syn-chronization (LCCS) / Core header (single; 16-bit XOR mask) / Type header (single; 16-bit XOR mask)PCS: Ordered Set continuous (Remote Fault, Local Fault, User)MAC: CRC (single, rates)Payload: Bit Errors (single, rates)
TESTPOINT 10GBPS
14
ERROR MONITORINGGFP: Loss of frame delineation (LFD) / LCS count / LCCS count / undefined fields CSF count / pFCS errors / single-bit cHEC errors / multi-bit cHEC errors PCS: Remote Fault, Local FaultMAC: Frames too long (>jumbo) / Jabbers / Undersized / Fragments / CRC errors / In-range length errors (802.3 frames)
STATISTICSPCS: Bandwidth (Mbps , %, frames/s)GFP: Data frame count / GFP Idle frame countMAC: Frame count / octet count / unicast frames / multicast frames / broadcast frames / single / stacked VLAN tagged frames / frame length bins (including jumbo) / CRC counts (total and lengths bins)Payload: Byte count
FILTERSMAC: 8 MAC / VLAN filters with accept / discard operation
CAPTURESTwo modes: 64B / 66B PCS, and MAC levelPCSTriggers: Manual / Remote Fault / Local Fault / control code match / block type field match / data pattern match (up to 8 bytes)Trigger point: Start / middle / endDisplay: Trigger point / 64B / 66B blocks as in Figure 49-7 IEEE 802.3ae-2005Size: 3,355,400 64B / 66B blocksFile type: Binary / ASCII
MACTriggers: Manual / CRC error / undersized frame / frame too long / in-range length errorTrigger point: Start / middle / endFilters: MAC filters / pattern filterDisplay: Trigger point / timestamp / MAC layer decodeSize: 400,000 frames / 32.4 Mbytes / full frame or slicing (first 64 bytes)File type: Binary (snoop compatible with Wireshark)
GFP-T with 8GFC Client Mapped into OPU2
Full OTU2 wrapper as described under Digital Wrapper and FEC Full 8GFC client as described under 8GFC
TRAFFIC SETTINGSHeader settings: PLI (auto-calculate on / off) / PTI / EXI / UPI / pFCS (on / off) / linear extension header (on / off) / channel ID / spare cHEC error correction on / off on receive Scrambler: Core header scrambler (enable / disable); payload header scramble(enable / disable) Superblocks per Frame: Range of 1 to 512 Transmission rate: Specified as bandwidth (Mbps ) / number of GFP Fixed Idle frames; range 0 to 65,535 bytesClient Rate Adaptation: adjust client rate in ± ppm
ERROR INJECTIONSGFP: Loss of client signal (LCS) / loss of client character synchronization (LCCS) / short GPF frame / pFCS / PLI (single, 15-bit x or mask) / Idle GFP frame (single, 16-bit x or mask) / core header (single, rates; 16-bit x or mask) / type header (single, rates; 16-bit x or mask) / Extension header (single; 16-bit x or mask) Superblock: CRC (single, rates, burst; 16-bit x or mask) / Flag Bit Error (single, rates; 8-bit x or mask)
ERROR MONITORINGGFP: Loss of frame delineation (LFD) / LCS count / LCCS count / short GFP frames / undefined fields (client signal Fail, PTI, EXI) / pFCS errors / total errored frames / single-bit cHEC errors / multi-bit cHEC errors / single-bit tHEC errors / multi-Bit tHEC errors / single-bit eHEC errors / multi-Bit eHEC errors Superblock: CRC correctable, uncorrectable / 10B_ERR
STATISTICSGFP: Bandwidth (Mbps , %, frames/s) / frame count / octet count / management frame count / GFP Idle frame count Superblock: superblocks per frame / total superblocks / 65B_PAD / 65B_PAD/sPattern Filter: pattern matched frames
FILTERSPattern filter: Up to 6 bytes with mask and offset from start of GFP frame
CAPTURESTriggers: Manual / LFD / single-bit cHEC error / multi-bit cHEC error / tHEC error / eHEC error / pFCS error / management frame / large GFP frame (with threshold) / Superblock CRC correctable, uncorrectable / Ctrl Code Match / Data Pattern Match (8 bytes) Trigger point: Start / middle / end Filters: Exclude Idle frame (on / off) Display: Trigger point / Timestamp / GFP and MAC layer decode Size: 700,000 frames / 32.4 Mbytes / full frame or slicing (first 64 bytes) File type: Binary (Snoop) / ASCII
cHDLC
cHDLC is Cisco-HDLC. Two possible mappings: in OC-192 / STM-64 (STS-192c / VC-4-64c); or in OC-192 / STM-64 wrapped in OTU2
TRAFFIC SETTINGS
Two modes: Single stream / multiple streams
SINGLE STREAMUsed for BERT testingSend mode: Continuous / burst of framesProtocol support: IPv4 (can also support MAC / single / stacked VLAN directly in HDLC). User can set header values including address / control / protocolFrame size: Range of 9 to 65,535 bytes. Size can be: fixed / incrementingFCS Size: CRC-32Transmission rate: Specified as number of flags (fixed) between 1 and 65,535Frame payload: PRBS 15, 23 or 31 / 16-byte sequence / pat-tern invert
MULTIPLE STREAMSUsed for traffic simulation and multi-protocol support
Maximum number of streams: 128Send mode: Continuous / burst of framesProtocol support: MPLS / IPv4 / TCP / UDP. User can set header values per stream (HDLC address / control / protocol values are global)
Frame size: range of 37 to 9,600 bytes. Size is fixed within a streamFCS Size: CRC-32Transmission Rate: BW% / number of flags in bytes / frames/sAuto-scale BW: Scales bandwidth when total exceeds 100%Frame payload: Fill byte / random / custom (user defined byte-by-byte)Stream signature: Used for receive auto-detection
CONTROL PLANE
SLARP: Filters out SLARP packets from data stream
ERROR INJECTIONS
Abort (single) / FCS (single)
ERROR MONITORING
FCS errors / frames too short (threshold) / address mismatches / control mismatches / abort errors / invalid control sequences / IPv4 checksum errors (single stream)
STATISTICS
Bandwidth (%, Mbps , frames / s) / frame count / octet count / SLARP packet count / IPv4 packet count (single stream)
Service Disruption TimeMeasurement: μs resolutionStatistics: Current / Previous / Minimum / Maximum / Average / CountEvent LoggingAutomatic re-triggeringTriggers:10GE LAN and Fibre Channel: LOS / PRBS Sync / PCS Sync
SONET/SDH: LOS / LOF / PRBS Sync / AIS-L/MS-AIS / AIS-P/AU-AIS / OOF / RDI-L/MS-RDI / RID-P/AU-RDI / B1 / B2 / B3
TESTPOINT 10GBPS
15
ORDER INFORMATION
TS-30 / 170
Module
N530-0163 10 Gbps module –XFP Version N530-0163-PA1 Electrical Production Package 9.9G-10.5GN530-0163-PA2 Electrical Production Package 8.5G-11.3G
Hardware optionOPT 0160-03 OTN DW & GFEC for 10Gbps moduleOPT 0163-04 OTN DW & GFEC / EFEC I.4 for 10Gbps module
InterfacesOPT 0164-11 1310 nm XFP optics for 10Gbps moduleOPT 0164-12 1550 nm XFP optics for 10Gbps moduleOPT 0164-13 850 nm XFP optics for 10Gbps moduleOPT 0164-45 Differential electrical XFP for 10Gbps module
Software options
OPT 0160-05 10G GFP for 10Gbps moduleOPT 0160-06 11.27G FEC extended rate for 10Gbps moduleOPT 0160-07 cHDLC for 10Gbps moduleOPT 0160-08 11.317G FEC extended rate for 10Gbps moduleOPT 0160-09 10G WAN for 10Gbps moduleOPT 0160-10 ExStreams Ethernet Multi-Streaming
for 10Gbps module (4096 streams )OPT 0160-15 10G FC for 10bps moduleOPT 0160-30 ODU2 10.037G digital wrapper for 10Gbps moduleOPT 0160-34 OC-192 / STM-64 channelization for 10Gbps module (Includes full
concatenation)OPT 0163-41 8GFC for 10Gbps moduleOPT 0160-44 GFP-F with preambles in extended OPU2 for TS-10 10GbpsOPT 0163-43 GFP-T for 8GFC client for 10Gbps module
Packages
OPT 0160-14 10G LAN / WAN and OC-192c / STM-64c for 10Gbps module
OPT 0160-16 10G LAN and OC-192c / STM-64 for 10 Gbps module
OPT 0160-17 10G LAN / WAN and OC-192c / STM-64c & 10GFC for 10Gbps moduleOPT 160-31 11.2709G/11.317G FEC extended rate
for 10 bps moduleOPT 0163-42 8G / 10GFC for 10Gbps module
AccessoriesOPT 022x-10 Wheeled hard travel case
accepting TS-10 or TS-30 chassis
TS-10 10Gbps configurationN550-0228 TS-10 10 Gbps XFP Version N550-0228-PB1 Electrical Production Package 9.9G-10.5GN530-0228-PB2 Electrical Production Package 8.5G-11.3G
Hardware option
OPT 0221-03 OTN DW & GFEC for TS-10 10Gbps OPT 0228-04 OTN DW & GFEC / EFEC I.4 for TS-10 10Gbps
Interfaces
OPT 0225-11 1310 nm XFP optics for TS-10 10Gbps
OPT 0225-12 1550 nm XFP optics for TS-10 10Gbps OPT 0225-13 850 nm XFP optics for TS-10 10Gbps OPT 0225-45 Differential electrical XFP for TS-10 10Gbps
Software optionsOPT 0221-05 10G GFP for TS-10 10Gbps OPT 0221-06 11.27G FEC extended rate for TS-10 10Gbps OPT 0221-07 cHDLC for TS-10 10Gbps OPT 0221-08 11.317G FEC extended rate for TS-10 10Gbps OPT 0221-09 10G WAN for TS-10 10Gbps OPT 0221-10 ExStreams Ethernet Multi-Streaming
for TS-10 10Gbps (4096 streams) OPT 0221-15 10G FC for TS-10 10Gbps
OPT 0221-30 ODU2 10.037G digital wrapper for TS-10 10GbpsOPT 0221-34 OC-192 / STM-64 channelization for TS-10 10Gbps (Includes full concat-
enation)OPT 0228-41 8GFC for TS-10 10Gbps OPT 0221-44 GFP-F with preambles in extended OPU2
for TS-10 10bpsOPT 0228-43 GFP-T for 8GFC client for TS-10 10Gbps
PackagesOPT 0221-14 10G LAN / WAN & OC-192c / STM-64c
for TS-10 10Gbps OPT 0221-16 10G LAN and OC-192c / STM-64
for TS-10 10GbpsOPT 0221-17 10G LAN / WAN & OC-192c / STM-64c & 10GFC for TS-10 10Gbps OPT 0221-31 11.270G/11.317G FEC extended rate
for TS-10 10GbpsOPT 0228-42 8G / 10GFC for TS-10 10Gbps
TESTPOINT 10GBPS
16
TestPoint 1Gbps
Highlights
Applications
Validates FC links –
Tests Ethernet Transport –
Provides FC traffic blasting up to 4 Gbps –
Compliance
CSA Certificate of Compliance to CAN / –CSA C22.2 No.60950-1 (2003) and ANSI / UL 60950-1 (2003) with CSA Mark for Canada and USA
CSA CB Certificate of Compliance to –EN60950-1, IEC 60950-1, and National Deviations with CE Marking
Class 1 Laser Product in compliance with –EN 60825, IEC 60825, and FDA / CDRH requirements
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS
Most comprehensive lower layer testing for Ethernet and Fibre Channel
Controls two independent ports •
Test rates up to 4 G with one module: 1 / 2 / 4G Fibre •Channel (FC), Optical Gigabit Ethernet (GigE), 10 / 100 / 1000BASE-T, 100BASE-FX
Captures 8B / 10B PCS and MAC traffic•
Generates up to 4096 unique traffic streams in ExStreams •mode (MAC / stacked VLAN, MPLS, IPv4, IPv6)
Executes RFC 2544 test suite on both Ethernet and Fibre •Channel
Measures service disruption time•
Terminal and transparent monitor connectivity modes•
The JDSU TestPoint 1Gbps Module provides two test ports for Ethernet from 10 Megabit to 1 Gigabit or 1 / 2 / 4 Gigabit Fibre Channel (FC) with a strong focus on lower-layer testing.
Licensed options control the available protocols and line rates. Both ports may be used concurrently with each being independently controlled. The test interface uses small form-factor pluggable (SFP) sockets which support optical and electrical connectivity options, and enable the convenience of changing wavelengths and protocols. Traffic generation of up to 128 streams is provided on all supported Ethernet rates in standard configuration. With the ExStreams option, up to 4096 streams can be generated and analyzed.
The TestPoint 1Gbps Module can be inserted into multiple scalable chassis options, including the highly compact TS-10 configuration. Up to sixteen 1Gbps modules can be inserted into the TS-170 for a total of 32 test ports in a single chassis.
Note: The TestPoint 1 Gbps is available as a module for multi-slot systems (TestPoint TS-30 and TS-170) or in a static, self-contained configuration (TestPoint TS-10). The term module is used in this document
17
TESTPOINT 1GBPS
INTERFACE SPECIFICATIONS
Optical / electrical SFPOptical connector LC LC LCWavelength 850 nm 1310 nm 1550 nmOptical output power (Rx power read) -9.5 to -2.5 dBm Up to -3 dBm -5 to 0 dBmOptical overload (min) 0 dBm 0 dBm 0 dBmSensitivity (min) -18 (4G); -21 (2G);
-22 (1G) dBm-23 dBm
Electrical connector RJ45; supports full-duplex 10BASE-T, 100BASE-TX, 1000BASE-T
Differential electrical SFPConnectorImpedance single-ended 50 OhmCable length 14 inchesType SMATransmitterMinimum single-ended amplitude 265 mVMaximum single-ended amplitude 800 mVReceiverSensitivity with PRBS23 @BER10-12 (single-ended peak-to-peak)
150 mV
Clock outputOutput level LVPECL signal, AC coupledConnector SMA / 50 OhmManagement ports10/100Base-T LAN (Ethernet) via RJ45Operator port via RJ12 into RS-232 serial cableLAN management portSupports simple network time protocol (SNTP) configurable for static IP address or DHCP
OPTICALReceive power measurementTransmit laser on / offSFP information display
LINE RATES10 / 100 / 1000 Mbps (BASE-T)125 Mbps (100BASE-FX)1.0625 Gbps (1GFC)1.25 Gbps (Optical GigE)2.125 Gbps (2GFC)4.25 Gbps (4GFC)
CLOCKINGInternal (± 4.6 ppm accuracy)Recovered from lineExternal via group controller: TS-30 / 170Clock rate variations : ± 110 ppmClock output
LOGGINGEvent log
Log injections
CONNECTIVITYTerminal: Source and sink trafficTransparent monitor: Transparently monitors and retransmits unaltered
APPLICATIONS
Description of the applications:Fibre Channel: 1 / 2 / 4GFCEthernet: Optical GigE and / or 10 / 100 / 1000BASE-T and / or 100BASE-FXApplications are switchable between FC and Ethernet; however, both ports run either FC or Ethernet
FIBRE CHANNEL
This covers 1 / 2 / 4GFC point-to-point. Used for BERT testing at the FC-1 and FC-2 layers. Applies to each port individually or both ports.
TRAFFIC SETTINGS
Send mode: Continuous / burst of framesFrame size: Range of 12 to 4,104 bytes (multiple of 4, includes SOF & EOF). Size can be: Fixed / incrementing / decrementing / random / user sequence (up to 8)Transmission rate: Specified as bandwidth (%, Mbps, frames/s) / number of inter frame gap (IFG) bytes (fixed / random / sequence up to 8; range 8 to 65,535 bytes)FC-2 framing: User can set 24-byte header valuesClass support: Class 3Flow control: Manual buffer-to-buffer credit setting; range 1 to 4,095. Sending of R_RDY may be enabled / disabled.Frame payload: PRBS 23 or 31 / 16-byte sequence / pattern invert
LINK INITIALIZATIONSettings: Enable / disable. LF1 / LF2 state forceReporting: Active sate indicator / LF1 / LF2 / primitive sequence protocol error count / loss of sync count / Link Failure count
ERROR INJECTIONSPCS sublayer: LOS / running disparity error (single, rates) / 8B / 10B coding error (single, rates) / random bit corruptionFC-1: Misaligned frames (non-multiple of 4 bytes size) FC-2: CRC (single, rates)
18
ERROR MONITORING
PCS sublayer: LOS / synchronization / running disparity errors / invalid 8B / 10B code groups / short IFGs (adjustable threshold)FC-1: Frames oversized (>2148 bytes) / frames undersized (<36 bytes) / frames misaligned (non-multiple of 4 bytes)FC-2: CRC errors
STATISTICSFC-1: Bandwidth (%, Mbps, frames/s) / frame count / octet count / number of R_RDY
LATENCY AND SEQUENCINGSequencing: Frame loss / out-of-order / duplicates. Can inject errors on transmitTime stamping: Latency (min, max, avg over test period and 0.5 s window) / packet jitter
CAPTURESCaptures 8B / 10B codesTriggers : Manual / sync loss / invalid 8B / 10B code group / running disparity error / code group pattern match (up to 6 bytes)Trigger point: Start / middle / endDisplay: Trigger point / 8B / 10B code group and decode (D / K codes and hex)Size: 8,250,000File type: Binary / ASCII
RFC 2544As described under Ethernet
TEST REPORTContains FC settings, errors, and statistics
TEST PATTERNSTransmits CJTPAT, CRPAT and CSPAT
ETHERNET
Description covers optical GigE 10 / 100 / 1000BASE-T, and 100BASE-FX, based on the SFP used. Applies to each port indi-vidually or both ports.
TRAFFIC SETTINGSThree modes: Single stream, multiple streams (physical ports), and optional multiple streams (logical ports ExStreams)
Single StreamUsed for BERT testing at PCS, MAC, single / stacked VLAN, and IPv4 layers.
Send mode: Continuous / burst of framesProtocol support: MAC / single stacked VLAN / LLC / SNAP / IPv4. User can set header values. For destination / source MAC address and VLAN IDs, support of single / incrementing value over a range.Frame size: Range of 19 to 65535 bytes. Size can be : Fixed incrementing / decrementing / random / user sequence (up to 8)Transmission rate: Specified as bandwidth (%, Mbps, frames/s) or number of inter frame gap (IFG) bytes (fixed / random / sequence up to 8; range 8 to 16,777,215 bytes)Frame payload: PRBS23, or 31 / 16-byte sequence / pattern invert
Multiple Streams
Used for traffic simulation and multi-protocol supportMaximum number of streams: 128 for physical ports / 4060 for logical ports (ExStreams)Number of logical ports (ExStreams): User setting to 1, 2, 4, 8, 16 or 32. Per transmit port, up to 4096/[# of logical ports] streams can be defined. Each receive port can detect up to 4096 streamsSend mode: Continuous / burst of framesProtocol support: MAC / single / stacked VLAN / MPLS / IP4 or IPv6./ TCP / UDP in the case of physical ports streaming. User can set header value per stream.Frame size: Range of 27 to 9,600 bytes. Size is fixed with a stream.Transmission rate: BW % / IFG size in bytes / [frame/s]. IFG does not apply to 10 / 100 / 1000BASE-TAuto-scale BW: Scales bandwidth when total exceeds 100%Frame payload: Fill byte / random / custom (user defined byte-by-byte)Stream signature: Used for receive auto-detection
AUTO-NEGOTIATIONDifferent implementation for optical GigE and 10 / 100 / 1000 BASE-T; does not apply to 100BASE-FX.
Optical GigE
Settings: Enable / disable. Remote fault (offline, link failure, auto-neg error) / pause encoding / operation modeReporting: Auto-negotiation complete indicator. Remote fault (offline, link failure, auto-neg error)Capture: Using 8B / 10B capture
10 / 100 / 1000BASE-T
Setting: Enable / disable. Full duplex only. Rate to negotiate / pause encodingReporting: Auto-negotiation complete indicator
CONTROL PLANEPause frames: Single / continuous with interval. Pause timer. Receiver throttles.ARP: ARP request sent for each unique destination IP address; Timeout, Retry Period and Count supportARP Reply sent on port MAC address match Gateway and Subnet Mask Settings
PINGSend mode: Continuous / packet countTransmission period: 1,000 to 4,294,967,295 msProtocol support: IPv4 with no VLAN / single or stacked VLANData size: 0 to 9554 bytesReplies: Issued on port IP address match
ERROR INJECTIONSPCS / PMA Sublayer: Optical GigE: LOS / running disparity error (single, rates) / [8B / 10B coding error (single, rates) ] / random bit corruption (single, rates)10BASE-FX: LOS / sync far end fault / invalid codeMAC sublayer: Short preamble (single stream) / long preambles (single stream) / CRC (single, rates in single stream; per stream in multiple streams)
ERROR MONITORING
TESTPOINT 1GBPS
19
PCS / PMA sublayer: Optical GigE: LOS / PCS synchronization / running disparity errors / invalid 8B / 10B code groups100BASE-FX: LOS / sync / far end fault / invalid codesMAC sublayer: Frames too long (>jumbo) / jabbers / undersized / fragments / CRC errors / in-range length errors (802.3 frames) / short IFGs (adjustable threshold, does not apply to 10 / 100 / 1000BASE-T)IPv4: Checksum errors (single stream)
STATISTICSMAC: Bandwidth (%, Mbps, frames/s) / frame count / octet count / unicast frames / multicast frames / broadcast frames / [single / stacked VLAN tagged frames] / number of pause frames / ARP frames / MPLS tagged frames / frame length bins (including jumbo) / CRC counts (total and length bins) / short preamble count / long preamble countMPLS : Frame countIPv4: Packet count / ICMP packetsIPv6: Packet Count / ICMP packetsPer stream statistics: Valid frames / valid bytes / frame rate (fps) / BW in % / BW in Mbps / MAC CRC error count / frames lost (count / ratio) / frames duplicated / frames out of order
In logical ports multiple streams (ExStreams), a linked error summary is provided
LATENCY AND SEQUENCING
In single-stream mode
Sequencing: Frame loss / out-of-order / duplicates. Can inject errors on transmitTime stamping: Latency (min, max, avg over test period and 0.5 s window) / packet jitter
FILTERSMAC: 8 MAC / VLAN filters with accept / discard operationPattern filter: Up to 6 bytes with offset from start of frame
CAPTURESTwo modes: 8B / 10B PCS, and MAC level
PCS
Triggers : Manual / PCS sync loss / invalid 8B / 10B code group / running disparity error / code group pattern match (up to 6 bytes)Trigger point: Start / middle / endDisplay: Trigger point / 8B / 10B code group and decode (D / K codes and hex)Size: 8,250,000 code groupsFile type: Binary / ASCII
MAC
Triggers: Manual / CRC error / undersized frame / frame too long / in-range length errorTrigger point: Start / middle / endFilters: MAC filters / pattern filterDisplay: Trigger point / time stamp / MAC layer decodeSize: 400,000 frames / 32.4 Mbytes / full frame or slicing (first 64 bytes)File type: Binary (Snoop compatible with Wireshark)
RFC 2544
Provides throughput, latency, frame loss, and back-to-back measurements in single stream mode. Up to 10 frame sizes. Supports function to run all tests in succession. Logs results to file and generates graphics
TEST REPORTContains Ethernet settings, errors, and statistics
DISRUPTION TIMEMeasurement: µs resolutionStatistics: Current / Previous / Minimum / Maximum / Average / CountEvent loggingAutomatic re-triggeringTriggers: LOS (not applicable for 10/100/1000BASE-T) / PRBS Sync / PCS Sync
TESTPOINT 1GBPS
20
ORDER INFORMATION
TS-30 / 170
1Gbps Module
N530-0134 1 Gbps Module − Dual port module supporting GigE / Ethernet & FC
Options
OPT 0134-10 Dual GigE / EthernetOPT 0134-11 Dual 1 / 2GFCOPT 0134-33 Dual 4GFCOPT 0134-14 Dual 1 / 2 / 4GFCOPT 0134-16 ExStream Ethernet Multiple Streaming
SFP interfaces
OPT 0134-01 GigE / 1 / 2 G FC 1310 nm SFP opticsOPT 0134-02 GigE / 1 / 2 G FC 1550 nm SFP opticsOPT 0134-03 GigE / 1 / 2 G FC 850 nm SFP opticsOPT 0134-35 GigE / 1 / 2 / 4 G FC 850 nm SFP opticsOPT 0134-36 GigE / 1 / 2 / 4 G FC 1310 nm SFP opticsOPT 0134-04 10 / 100 / 1000 Electrical SFPOPT 0134-08 100BASE-FX 1310 nm SFP opticsOPT 0134-38 Differential electrical SFP for 1 Gbps module
TS-10 1 Gbps configuration
N550-0224 TS-10 with 1 Gbps Configuration – Dual Port Module supporting GigE / Ethernet & FC
Options
OPT 0224-10 Dual GigE / EthernetOPT 0224-11 Dual 1 / 2GFC OPT 0224-33 Dual 4GFCOPT 0224-14 Dual 1 / 2 / 4GFCOPT 0224-16 ExStream Ethernet Multiple Streaming
SFP interfaces
OPT 0224-01 GigE / 1 / 2 G FC 1310 nm SFP optics OPT 0224-02 GigE / 1 / 2 G FC 1550 nm SFP opticsOPT 0224-03 GigE / 1 / 2 G FC 850 nm SFP opticsOPT 0224-35 GigE / 1 / 2 / 4 G FC 850 nm SFP opticsOPT 0224-36 GigE / 1 / 2 / 4 G FC 1310 nm SFP opticsOPT 0224-04 10 / 100 / 1000 Electrical SFPOPT 0224-08 100BASE-FX 1310 nm SFP opticsOPT 0224-38 Differential electrical SFP for TS-10 1 Gbps
Accessories
OPT 022x-10 Wheeled hard travel case accepting TS-10 or TS-30 chassis
TESTPOINT 1GBPS
21
Highest integration of line rates for multi-protocol testing
Tests the following protocols with one module – •OC-3 / 12 / 48, STM-1 / 4 / 16, OTN, Ethernet, 1 / 2G Fibre Channel (FC)
Comprehensive support for OTN related rates – OTU1 •(2.666 G) and ODU1 (2.498 G)
Maps GFP-F and ATM into SONET / SDH•
Unique capability of Ethernet over PDH (ITU-T G.7043)•
Supports a wide variety of Ethernet interfaces: •1000BASE-X, 10 / 100 / 1000BASE-T, 100BASE-FX
The TestPoint Multi-Rate Module is a single-slot, customizable module with three physical ports: OC-48/STM-16 (option for G.709 OTN), OC-3 /12 / STM-1/4, and Ethernet / Fibre Channel.
One physical port can be active at a time for testing and at least one synchronous optical network technologies / synchronous digital hierarchy (SONET / SDH) port must be licensed. For the convenience of changing wavelengths and protocols, pluggable SFP optical / electrical interfaces are used. Traffic generation of up to 128 streams is provided on all supported Ethernet rates.
A hardware option provides OTU1 support on the OC-48 / STM-16 port. Both SONET / SDH ports support licensed options for Ethernet over SONET / SDH (VCAT and GFP-F) and asynchronous transfer mode (ATM). Additional options include Ethernet over PDH (EoPDH) (DS1 / E1 / DS3 / E3 into SONET / SDH with GFP-F / HDLC payload), RPR Intrusive Monitor Mode on OC-48 / STM-16, and ODU1 line rate (2.499 G). The Multi-Rate Module can be inserted into multiple scalable TestPoint chassis including the highly compact TestPoint TS-10. Up to sixteen Multi-Rate modules can be inserted into the TS-170 for a high-density, rack-mounted test solution.
NOTE: The TestPoint Multi-Rate is available as a module for multi-slot systems (TestPoint TS-30 and TS-170) or in a static, self-contained configuration (TestPoint TS-10).The term module is used in this document.
TestPoint Multi-Rate
Highlights
Applications
Facilitates both line and client testing –
Tests Ethernet and Fibre Channel trans- –port
Provides 2.7 Gbps and below traffic blast- –ing
Compliance
CSA Certificate of Compliance to –CAN / CSA C22.2 No.60950-1 (2003) and ANSI / UL 60950-1 (2003) with CSA Mark for Canada and USA
CSA CB Certificate of Compliance to –EN60950-1, IEC 60950-1, and National Deviations with CE Marking
Class 1 Laser Product in compliance with –EN 60825, IEC 60825, and FDA / CDRH requirements
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS
22
TESTPOINT MULTI-RATE
OPTICALReceive power measurementTransmit laser on / offSFP information display
LINE RATES10 / 100 / 1000 Mbps (BASE-T)125 Mbps (100BASE-FX)155.52 Mbps (OC-3 / STM-1)622.08 Mbps (OC-12 / STM-4)1.0625 Gbps (1GFC)1.25 Gbps (GigE)2.125 Gbps (2GFC)2.488 Gbps (OC-48 / STM-16)2.498 Gbps (ODU1)2.666 Gbps (OTU1)
CLOCKINGInternal (± 4.6 ppm accuracy)Recovered from lineExternal via group controller (TS-30 / TS-170)Clock rate variations± 30 ppm: SONET / SDH, OTU1± 110 ppm: Ethernet, FCClock out (LVPECL, AC coupled on SMA)
LOGGINGEvent logLog injections
CONNECTIVITYTerminal: Source and sink traffic (all rates)Transparent Monitor: Transparently monitors signal andretransmits unaltered (all SONET / SDH rates and OTU1)Intrusive Monitor: Intrusively injects errors while forwardingincoming traffic (RPR option only)
APPLICATIONS
Description of the applications
SONET / SDH:OC-3 / 12 / 48 and STM-1 / 4 / 16
Digital Wrapper and FECOTU1:Client can be PRBS or OC-48 / STM-16 ODU1:OTU1 frame structure without FEC
EthernetOptical GigE and / or 10 / 100 / 1000BASE-T and / or 100BASE-FX
Fibre Channel1 and 2GFC point-to-point
Ethernet over PDHDS1 / E1 and DS3 / E3 into OC-3 / 12 / 48 / STM-1 / 4 / 16PDH VCAT / LCAS is available on DS1 / E1MAC traffic on GFP-F / bit-HDLC / byte-HDLC (on DS1 / E1 only)
Ethernet over SONET / SDHGFP-F on OC-3 / 12 / 48 or STM-1 / 4 / 16Higher-Order VCAT on OC-48 / STM-16
RPRIntrusive monitor mode on OC-48 / STM-16 (STS-48c / VC-4-16c)
ATMOn OC-3 / 12 / 48, STM-1 / 4 / 16
SONET / SDH
CHANNELIZATIONOC-3: STS-3c / STS-1STM-1:VC-4 / VC-3 (AU-3)OC-12: STS-12c / STS-3c / STS-1STM-4:VC-4-4c / VC-4 / VC-3 (AU-3)OC-48: STS-48c / STS-24c / STS-12c / STS-3c / STS-1STM-16:VC-4-16c / VC-4-8c / VC-4-4c / VC-4 / VC-3 (AU-3) / VC-3 (TUG-3)
ALARMSMonitoring is performed on all paths concurrently in the event log
LOS / LOF / OOF / AIS-L / MS-AIS / RDI-L / MS-RDI / LOP-P / AU-LOP / AIS-P / AU-AIS / ERDI-P / HP-ERDI / UNEQ-P / HP-UNEQVC-3 (TUG-3):TU-AIS / TU-LOP / LP-RDI / LP-UNEQ
ERRORSMonitoring is performed on all paths concurrently in the event logSingle / Rates for LOF / AIS-L / MS-AIS / RDI-L / MS-RDI / REI-L /MSREI / REI-P / HP-REI / B1 / B2 / B3VC-3 (TUG-3):Single / Rates for LP-REI / LP-BIPDuration (in ms) for LOF / [AIS-L/MS-AIS] / [RDI-L/MS-RDI]
ENLARGED VIEW OF ERRORS & ALARMS REPORT
Up to 4 indicators of errors and alarms detected by the TestPoint. Object of each indicator can be chosen by user from the above list of alarms and errors.
TRAFFICPRBS 23 or 31 / 4-Byte Sequence / Pattern Invert
TRIGGER SIGNALOC-48 / STM-16: Output pulse either on received / transmitted A2 byte
DIGITAL WRAPPER AND FECCovers OTU1,ODU1. FEC does not apply to ODU1
ALARMS
LOS / OOF / LOF / OOM / LOM / OTU-AIS (PN-11) / OTU-IAE / OTU-BDI / OTU-BIAE / ODU-AIS (PM / TCM1-6) / ODU-LCK (PM / TCM1-6) / ODU-OCI (PM / TCM1-6) / ODU-BDI (PM / TCM1-6) / ODU-BIAE (TCM1-6)
ERRORSSingle / rates for OTU-BIP8 / OTU-BEI / ODU-BIP8 (PM / TCM1-6) / ODU-BEI (PM / TCM1-6)
OVERHEADSMulti Frame Structures: OTU-TTI / ODU-TTI (PM / TCM1-6) / ODU-FTFL / PSIJustification events: Sync (line-client locked) / async (range ± 70 ppm). Reporting of justification event ratio and line client ppm offsetByte diagram: User editable overhead fields / MFAS invert.Injection count in frames / continuous injection
Overhead PRBS: 3 independent PRBS 15 engines for GCC0-2 / RES (OTU, ODU, OPU) / TCM1-6 (TCM / ACT) EXPError suppression: To optionally suppress incoming errors / alarms: FEC / TCM1-6 errors / PM errors / client errors
CAPTURES
Triggers: Manual / OOF / LOF / OOM / LOM / OTU-IAE / OTU-BDI / OTU-BIAE / OTU-BIP8 / OTU-BEI / ODU-AIS (PM / TCM1-6) / ODU-LCK (PM / TCM1-6) / ODU-OCI (PM / TCM1-6) / ODU-BDI (PM / TCM1-6) / ODU-BIP8 (PM / TCM1-6) / ODU-BEI (PM / TCM1-6) / ODU-BIAE (TCM1-6) / positive justification / negative justification / over-head PRBS bit error / pattern match (equal, not equal) with bit-maskPattern Match Fields: FAS / MFAS / GCC0-2 / OTU RES / SM TTI / ODU RES1-3(TCM / ACT) FTFL / EXP / APS / PCC / TCM1-6 TTI / PM TTI / OPU RES1-3Trigger point: Start / middle / endDisplay: Trigger point / Hex values for all overhead fieldsSize: Overhead of 256 framesFile type: ASCII (csv)
CLIENTOC-48 / STM-16PRBS 23, 31 & 4-byte user pattern
23
FECSettings: Standard FEC / All-Zeroes FEC. Enable / Disable error correctionInjection: Single and rates. Control of errored sub-row (includ-ing all) / errored bytes per sub-row / errored bits per byte. Skipped rows between errors. Up to 16 symbol errors.Detection: Number of correctable byte errors / number of correctable bit errors / bit error rate / number of uncorrectable sub-rows
ETHERNETCovers optical GigE, 10 / 100 / 1000BASE-T, and 100BASE-FX depending on the SFP used
TRAFFIC SETTINGSTwo modes: Single stream, multiple stream
Single StreamUsed for BERT testing at PCS (optical GigE only), MAC, single / stacked VLAN, and IPv4 layers
Send mode: Continuous / burst of framesProtocol support: MAC (single / stacked VLAN) LLC / SNAP / IPv4. User can set header values. For destina-tion / source MAC addresses and VLAN IDs, support of single / incrementing value over a rangeFrame size: Range of 19 to 65,535 bytes (19 to 9,600 bytes for 10 / 100 / 1000BASE-T). Size can be: Fixed / incrementing / dec-rementing / random / user sequence (up to 8)Transmission rate: Specified as bandwidth (%,Mbps, frame/s) or number of inter frame gap (IFG) bytes (fixed / ran-dom / sequence up to 8; range 4 to 16,777,215 bytes). IFG does not apply to 10 / 100 / 1000BASE-TFrame payload: PRBS 23 or 31 / 16-byte sequence / pattern invert
Multiple StreamsUsed for traffic simulation and multi-protocol support
Maximum number of streams: 128Send mode: Continuous / burst of frames
Protocol support: MAC (single / stacked VLAN) MPLS / IPv4 / IPv6 / TCP / UDP. User can set header values per stream.Frame size: Range of 27 to 9,600 bytes. Size is fixed within a stream.Transmission Rate: BW % / IFG size in bytes / frames/s. IFG does not apply to 10 / 100 / 1000BASE-TAuto-scale BW: Scales bandwidth when total exceeds 100%. Frame Payload: Fill byte / random / custom (user defined byte-by-byte)Stream signature: Used for receive auto-detection
AUTO-NEGOTIATIONDifferent implementation for optical GigE and 10 / 100 / 1000BASE-T; does not apply to 100BASE-FX
Optical GigE
Settings: Enable / disable. Remote fault (offline, link failure, auto-neg error) / pause encoding / duplex settingsReporting: Auto-negotiation complete indicator. Remote fault (offline, link failure, auto-neg error)Capture: Using 8B / 10B PCS capture
10 / 100 / 1000BASE-T
Settings: Enable / disable. Full duplex only support. Rate to negotiate / pause encodingReporting: Auto-negotiation complete indicator
CONTROL PLANEPause frames: Single / continuous with interval. Pause timer. Receiver throttlesARP: ARP request sent for each unique destination IP address; Timeout, Retry Period and Count supportARP Reply sent on port MAC address matchGateway and Subnet Mask Settings
PingSend mode: Continuous / packet countTransmission period: 1000 to 4,294,967,295 msProtocol support: IPv4 with no VLAN, single VLAN and stacked VLANData size: 0 to 9,572 bytesReplies: Issued on port IP address match
ERROR INJECTIONSPCS / PMA sublayer:Optical GigE: LOS / running disparity error (single, rates) / (8B / 10B) coding error (single, rates) / random bit corruption 100BASE-FX: LOS / Sync / far end fault / invalid codeMAC sublayer: Short preambles (single stream) / long pre-ambles (single stream) / CRC (single, rates in single stream; per-stream in multiple streams)
ERROR MONITORING
PCS / PMA sublayer:Optical GigE: LOS / PCS synchronization / running disparityerrors / invalid 8B / 10B code groups100BASE-FX: LOS / sync / far end fault / invalid codesMAC sublayer: Frames too long (>jumbo) / jabbers / under-sized / fragments / CRC errors / in-range length errors (802.3 frames) / short IFGs (adjustable threshold, does not apply to 10 / 100 / 1000BASE-T)IPv4: Checksum errors (single stream)
STATISTICSMAC: bandwidth (%,Mbps, frames/s) / frame count / octet count / unicast frames / multicast frames / broadcast frames / single / stacked VLAN tagged frames / number of pause frames / ARP frames / MPLS tagged frames / frame length bins (including jumbo) / CRC counts (total and lengths bins) / short preamble count / long preamble countIPv4: Packet count / ICMP packetsIPv6: Packet count / ICMP packetsPer-stream statistics: Bandwidth (Mbps,%, frames/s) / frame count / octet count
LATENCY AND SEQUENCINGIn single-stream mode
Sequencing: Frame loss / out-of-order / duplicates. Can inject errors on transmitTime stamping: Latency (min, max, avg over test period and 0.5 s window; bit forwarding / store and forward) / packet jitter
FILTERSMAC: 8 MAC / VLAN filters with accept / discard criteriaPattern filter: Up to 6 bytes with offset from start of frame
CAPTURESTwo modes: 8B / 10B (optical GigE only), and MAC level
TESTPOINT MULTI-RATE
24
PCS
Triggers: Manual / PCS sync loss / invalid 8B / 10B code group / running disparity error / code group pattern match (up to 6 bytes)Trigger point: Start / middle / endDisplay: Trigger point / 8B / 10B code group and decode (D / K codes and hex)Size: 8,250,000 8B / 10B code groupsFile type: Binary / ASCII
MAC
Triggers: Manual / CRC error / undersized frame / frame too long / in-range length errorTrigger point: Start / middle / endFilters: MAC filters / pattern filterDisplay: Trigger point / time stamp / MAC layer decodeSize: 400,000 Frames / 32.4 Mbytes / full frame or slicing (first 64 bytes)File type: Binary (snoop compatible with Ethereal)
RFC 2544
Provides throughput, latency, frame loss, and back-to-back measurements in single-stream mode. Up to 10 frame sizes. Supports function to run all tests in succession. Logs results to file and generates graphics.
TEST REPORTContains Ethernet settings, errors, and statistics
FIBRE CHANNELThis covers 1 and 2G Fibre Channel point-to-point. Used for BERT testing at the FC-1 and FC-2 layers.
TRAFFIC SETTINGS
Send mode: Continuous / burst of framesFrame size: Range of 12 to 4,104 bytes (multiple of 4, includes SOF & EOF). Size can be: Fixed / incrementing / decrement-ing / random / user sequence (up to 8)Transmission rate: Specified as bandwidth (%,Mbps, frame/s) / number of inter frame gap (IFG) bytes (fixed / ran-dom / sequence up to 8; range 8 to 65,535 bytes)FC-2 framing: User can set the 24-byte header valuesClass support: Class 3Flow control: Manual buffer-to-buffer credit setting; range 1 to 4,095. Sending of R_RDY may be enabled / disabledFrame payload: PRBS 23 or 31 / 16-byte sequence / pattern Invert
LINK INITIALIZATIONSettings: Enable / disable. LF1 / LF2 state forceReporting: Active state indicator / LF1 report / LF2 report / primitive sequence protocol error count / loss of sync count / link fail countCapture: Using 8B / 10B PCS capture
ERROR INJECTIONSPCS sublayer: LOS / running disparity error (single, rates) / 8B / 10B coding error (single, rates) / random bit corruptionFC-1: Misaligned frames (non-multiple of 4 bytes size)FC-2: CRC (single, rates)
ERROR MONITORINGPCS sublayer: LOS / PCS synchronization / running disparity errors / invalid 8B / 10B code groups / short IFGs (adjustable threshold)
FC-1: Frames oversized (>2,148 bytes) / frames undersized (<36 bytes) / frames misaligned (non-multiple of 4 bytes)FC-2: CRC errors
STATISTICSFC-1: Bandwidth (%,Mbps, frames/s) / frame count / octet count / number of R_RDY
LATENCY AND SEQUENCINGSequencing: Frame loss / out-of-order / duplicates. Can inject errors on transmit.Time stamping: Latency (min, max, avg over test period and 0.5 s window) / packet jitter
CAPTURESAt the 8B / 10B PCS levelTriggers: Manual / PCS sync loss / invalid 8B / 10B charac-ter / running disparity error / character pattern match (up to 6 bytes)Trigger point: Start / middle / endDisplay: Trigger point / 8B / 10B character and decode (D / K codes and hex)Size: 8,250,000 8B / 10B charactersFile type: Binary / ASCII
RFC 2544Applies to FC as described under Ethernet
TEST REPORTContains FC settings, errors, and statistics
TEST PATTERNSCJTPAT / CRPAT / CSPAT
ETHERNET OVER PDHEoPDH is based on ITU-T G.7043 / 7042 and G.8040
DS1Mapping onto SONET is via VT1.5. Supports PDH VCAT / LCAS
Independent channels: 336 on OC-12 / 48, 84 on OC-3 for VCG member selectionFormat: ESF / SFPPM offset: ± 130 ppm relative to lineESF overheads: DL (data link) 6-bit programmable value / PRM (performance report message) 15-byte message injection and reportingESF errors: OOF / SEF / AIS / RAI / Idle / FPS bits (burst with mask, 10-3 rate, error reporting) / CRC-6 (single, 10-3 rate, error reporting)SF errors: FT OOF / FT & FS OOF / SEF / AIS / RAI / Idle / FT & FS bits (burst with mask, 10-3 rate, error reporting)Payload: PRBS 15 or 23 / 4-byte sequence into GFP-F, byte-HDLC or bit-HDLC (RFC 1662 or LAPS) with MAC encapsulation
E1Mapping onto SDH is via VC-12 using AU-3 or TU-3 VC-3 multi-plexing. Supports PDH VCAT / LCAS
TESTPOINT MULTI-RATE
25
Independent channels: 252 E1 channels on STM-4 / 16, 63 E1 channels on STM-1 for VCG member selectionFormat: PCM31CRC / PCM31
PPM Offset: ± 50 ppm relative to line
Overheads: Spare bits 5-bit programmable / Si 1-bit program-mable (PCM31) / MDL (message-based data link) PRBS testPCM31CRC errors: OOF / AIS / RAI / FAS bits (burst with mask, 10-3 rate, error reporting) / Non-FAS Bit 2 (burst, continu-ous) / CRC-4 (burst, rates, error reporting) / REBE (single with mask, 10-3 rate, error reporting)PCM31 errors: OOF / AIS / RAI / FAS bits (burst with mask, 10-3 rate, error reporting) / Non-FAS Bit 2 (burst, continuous)Payload: PRBS 15 or 23 / 4-byte Sequence into GFP-F, byte-HDLC or bit-HDLC (RFC 1662 or LAPS) with MAC encapsulation
DS3Mapping onto SONET is via STS-1Independent engines: 12 on OC-3 / 12 / 48; for parallel inde-pendent testing on each engineFormat: C-bit parity / pseudo M23 / unframedPPM Offset: ± 90 ppm relative to lineOverheads: MDL (maintenance data link) PRBS testC-bit parity errors: OOF / AIS / SEF / Idle / RAI / F-bits (single with value, 10-3 rate, error reporting) / M-bits (single with value, 10-3 rate, error reporting) / C-bit parity errors (single with mask, 10-3 rate, error reporting) / P-bit parity errors (single, 10-3 rate, error reporting) / FEBE (single, 10-3 rate, error reporting)Payload: PRBS 15 or 23 / 4-byte sequence into GFP-F, or bit-HDLC (RFC 1662) with MAC encapsulation
E3Mapping onto SDH is via VC-3 using AU-3 or TU-3 multiplexingIndependent engines: 12 on STS-1 / 4 / 16; for parallel inde-pendent testing on each engineFormat: G.832 (VLI on / off) / G.751 / unframedPPM Offset: ± 78 ppm relative to lineG.832 overheads: Trace message / MA payload type / MA SSM / network operator byte / GC PRBS testG.751 overheads: National bitG.832 errors: OOF / RDI / AIS / FAS (single with value, 10-3 rate, error reporting) / REI (single, 10-3 rate, error reporting) / BIP-8 (single, 10-3 rate, error reporting)G.751 errors: OOF / AIS / RAI / FAS (single with value, 10-3 rate, error reporting)Payload: PRBS 15 or 23 / 4-byte sequence into GFP-F, or bit-HDLC (RFC 1662) with MAC encapsulation
PDH VCAT / LCASNumber of members: Up to 16 (DS1 / E1)
Error injections: OOM1 / OOM2 / LOM (MFI1, MFI2) / SQ over-write / CTRL overwrite / RS_ACK toggle / suppress (LCAS) / MST invert (LCAS) / CRC (LCAS; single) / GID PRBS bit error (LCAS)
Error monitoring:OOM1 / OOM2 / LOM / SQM (VCAT; sequence indicator mismatch) / SQNC (LCAS; inconsistent sequence num-bers) / LOA (VCAT; loss of alignment) / MND (LCAS; member not deskewable) / DNU (LCAS) / CRC error count (LCAS)Error suppression: To optionally suppress non-member or noncandidate errors / alarmsLCAS status: Control word value / MST valueLCAS sink Config: User configures up to 32 candidate pathsMonitoring of CTRL packets from this list provides sink side VCG informationLCAS statistics: number of RS_ACK toggles
GFP-FSupport on EoPDH
TRAFFIC SETTINGSSend mode: Continuous / burst of framesHeader settings: PLI (auto-calculate on / off) / PTI / EXI / UPI / pFCS (on / off) / linear extension header (on / off) / channel ID / sparecHEC error correction on / off on receiveScrambler: Core header scrambler (enable / disable); payload header scrambler (enable / disable)Frame size: Range of 9 to 65,535 bytes (GFP frame)Size can be: Fixed / incrementing / decrementing (DS1 / E1 only) / random (DS1 / E1 only)Transmission rate: Specified as bandwidth (Mbps) / number of GFP Idle Frames (fixed / random)
ERROR INJECTIONSLoss of client signal (LCS) / loss of client character synchroniza-tion (LCCS) / short GFP frame / pFCS (single, rates on DS1 / E1 only) / Idle GFP frame (single, 16-bit x or mask) / core header (single, rates on DS1 / E1 only; 16-bit x or mask) / type header (single, rates on DS1 / E1 only;16-bit x or mask) / extension header (DS1 / E1 only; single, rates)
ERROR MONITORINGLoss of frame delineation (LFD) / LCS count / LCCS count / short GFP frames / undefined fields (DS1 / E1 only: Client signal fail, PTI, EXI) / pFCS errors / single-bit cHEC errors / multi-bit cHEC errors / single-bit tHEC errors / multi-bit tHEC errors / single-bit eHEC errors (DS1 / E1 only) / multi-bit eHEC errors (DS1 / E1 only)
StatisticsBandwidth (%,Mbps, frames/s) / frame count / octet count / management frame count
HDLCBit-HDLC comes two ways: RFC 1662 and LAPS. RFC 1662 is supported on DS1 / E1 / DS3 / E3, and LAPS is supported on DS1 / E1. LAPS Byte-HDLC (ITU-T X.86) is supported on DS1 / E1
Settings: RFC 1662 bit-HDLC / LAPS bit-HDLC (DS1 / E1 only) / LAPS byte-HDLC (DS1 / E1 only)Send mode: Continuous / burst of framesHeader settings: Address / control / protocol or SAPIFrame size: Range of 7 to 65,535 bytesSize can be: Fixed / incrementingTransmission rate: Specified as number of idle flags (fixed)Error injections: Abort (single) / FCS (single) / rate adaptation (byte-HDLC)Error monitoring: FCS errors / abort errors / frames too short (threshold) / frames too long (threshold) / address mismatch-es / control mismatches (byte-HDLC) / invalid control sequence (byte-HDLC) / invalid rate adaptation sequence (byte-HDLC)Statistics: Bandwidth (frames/s) / frame count / octet count
MACMAC maps into GFP-F or HDLC. On DS1 / E1, traffic maps on a VCG. On DS3 / E3, 12 independent traffic engines are available on 12 channels.Protocols: MAC / single VLAN (DS1 / E1 / DS3 / E3) / stacked VLAN with programmable Ethertype (DS3 / E3).User can set header valuesError injections: CRC (DS1 / E1 only; single, rates)Error monitoring: CRC errors / DS1 / E1 only: (frames too long / jabbers / undersized / fragments / in-range length errors)Statistics: Frame count / DS1 / E1 only: (octet count / unicast frames / multicast frames / broadcast frames / VLAN tagged Frames / frame length bins [HDLC only] / CRC error length bins [HDLC only])
ETHERNET OVER SONET / SDH
VCATOne VCAT group (VCG). Available on OC-48 / STM-16 port
Channelization: STS-3c-nV (8 members) / VC-4-nV (8 mem-bers) / STS-1-nV (24 members) / VC-3-nV (AU-3 / TUG-3; 24 members)Error injections: LOM (using MFI1 / MFI2) / SQM / multi-frame (16-frame) control packet editorError monitoring: LOM (per-member) / SQM (per-mem-ber) / LOA (adjustable threshold)Error suppression: To optionally suppress non-member errors / alarmsDifferential delay: Reporting of max differential delay in VCG. Injection on one VCG member of up to 256 ms.Capture: H4 Byte capture over 8 multi-frames (of 16 frames) for one VCG member
TESTPOINT MULTI-RATE
26
GFP-FAvailable on Contiguously concatenated SONET / SDH (OC-3 / 12 / 48 STM-1 / 4 / 16) and VCAT (OC-48 / STM-16)
TRAFFIC SETTINGSSend mode: Continuous / burst of framesHeader settings: PLI (auto-calculate on / off) / PTI / EXI / UPI / pFCS (on / off) / linear extension header (on / off) / channel ID spare. cHEC error correction on / off on receiveProtocol support: MAC / single or stacked VLAN. User can set header valuesScrambler: Core header scrambler (enable / disable); payload header scrambler (enable / disable)Frame size: Range of 9 to 65,535 bytes (GFP frame)Size can be: fixed / incrementing / decrementing / randomTransmission rate: Specified as bandwidth (Mbps) / number of GFP Idle Frames (fixed / random; range 0 to 65,535 bytes)Frame payload: PRBS 23 or 31 / 4-byte sequence
ERROR INJECTIONSGFP: Loss of client signal (LCS) / loss of client character synchronization (LCCS) / short GFP frame / pFCS (single, rates) / idle GFP frame (single, 16-bit x or mask) / core header (single, rates; 16-bit x or mask) / type header (single, rates; 16-bit x or mask) / extension header (single, rates; 16-bit x or mask) MAC: CRC (single, rate)
ERROR MONITORING
GFP: Loss of frame delineation (LFD) / LCS count / LCCS count / short GFP frames / undefined fields (client signal fail, PTI, EXI) / pFCS errors / single-bit cHEC errors / multi-bit cHEC errors / single-bit tHEC errors / multi-bit tHEC errors / single-bit eHEC errors / multi-bit eHEC errorsMAC: Frames too long (>jumbo) / jabbers / undersized / frag-ments / CRC errors / in-range length errors (802.3 frames)
STATISTICSGFP: Bandwidth (Mbps,%, frames/s) / frame count / octet count / management frame count / GFP Idle Frame countMAC: Frame count / octet count / unicast frames / multicast frames / broadcast frames/single / stacked VLAN tagged frame
FILTERSPattern filter: Up to 6 bytes with offset from start of GFP frame
CAPTURES
Triggers: Manual / GFP LFD / single-bit cHEC error / multi-bit cHEC error / tHEC error / eHEC error / pFCS error / management frame / large GFP frame (with threshold) / MAC CRC errorTrigger point: Start / middle / endFilters: Pattern filter / exclude GFP Idle optionDisplay: Trigger point / Time stamp / GFP and MAC layer decodeSize: 700,000 frames / 32.4 Mbytes / full frame or slicing (first 64 bytes)File type: Binary (Snoop) / ASCII
RPRIntrusive monitor mode only on OC-48 / STM-16 (STS-48c / VC-4-16c). RPR frames are encapsulated in GFP. RPR impairments are created based on triggering criteria applied to incoming frames
TRIGGERINGAn AND relation applies between the frame fields selected as available triggers for one specific frame type.
Frame type: 1 choice from: Data (regular, extended) / con-trol / fairness / idleTrigger condition: Equal / not equalFrame fields: TTL (all) / ringlet ID (all) / fairness eligible (all) / service class (all) / wrap eligible (all) / parity (all) / des-tination address (data, control; with mask) / source address (data, control; with mask) / TTL BASE- (data, control) / flooding indication (data, control) / passed source (data, control) / strict order (data, control) / res (data, control, fairness) / HEC (data, control) / protocol type (data) / DA extended (data; with mask) / SA extended (data; with mask) / control type (control) / control version (control) / SA compact (fairness, idle; with mask) / fairness frame type (fairness) / fairness rate (fairness)
IMPAIRMENTSFor the frames matching the triggering criteria, an impairment control engine narrows down the number of frames to impair. An AND relation applies between the selected fields to impair for a specific frame type.
Impairment control: Continuous / periodic (on / off peri-ods) / burstFrame type: 1 choice from: Data (regular, extended) / con-trol / fairness / idleImpairment action: Overwrite / invert / increment (TTL) / decrement (TTL)Frame fields: TTL (all) / ringlet ID (all) / fairness eligible (all) / service class (all) / wrap eligible (all) / corrupt parity (all) / destination address (data, control; with mask) / source address (data, control; with mask) / TTL BASE (data, con-trol) / flooding indication (data, control) / passed source (data, control) / strict order (data, control) / res (data, control, fair-ness) / HEC (data, control) / protocol type (data) / DA extended (data; with mask) / SA extended (data; with mask) / control type (control) / control version (control) / SA compact (fairness, idle; with mask) / fairness frame type (fairness) / fairness rate (fairness) / corrupt FCS (all)
ERROR MONITORINGGFP: Loss of frame delineation (LFD) / LCS count / LCCS count / short GFP frames / undefined fields (client signal fail, PTI, EXI) / pFCS errors / single-bit cHEC errors / multi-bit cHEC errors / single-bit tHEC errors / multi-bit tHEC errors / single-bit eHEC errors / multi-bit eHEC errorsRPR: Frames too long (data, control) / undersized (data, control) / HEC error (data, control) / invalid length (fairness, idle) / parity errors / FCS errors
STATISTICSIncoming GFP: Bandwidth (%,Mbps, frames/s) / frame count / octet count / management frame countIncoming RPR frames: Total bandwidth (Mbps, frames/s) / total frame count / total octet count / frame count & BW (data, control, fairness, idle) / octet count (data, control, fairness, idle) / per-class data frames & BW (class A A1, A A0, B CIR, B EIR, C) / unicast data frames / multicast & broadcast data frames / broadcast data frames / jumbo data framesOutgoing RPR frames: Total frame count / total octet count / frame count (data, control, fairness, idle) / per-class data frames (Class A A1,A A0,B CIR, B EIR, C) / Unic frames / multicast and broadcast data frames / broadcast data frames / jumbo data frames / triggered frame count / impaired frame count
TESTPOINT MULTI-RATE
27
CAPTURESFrames are captured at the GFP levelTriggers: Manual / GFP LFD / single-bit cHEC error / multi-bit cHEC error / tHEC error / eHEC error / pFCS error / management frame / large GFP frame (with threshold) / MAC CRC errorTrigger point: Start / middle / endFilters: Pattern filter up to 6 bytes with offset from start of GFP frameDisplay: Trigger point / time stamp / GFP layer decodeSize: 700,000 frames / 32.4 Mbytes / full frame or slicing (first 64 bytes)File type: Binary (Snoop) / ASCII
ATM
TRAFFIC SETTINGSTwo configuration options are available, based on engine lineups: File playback, PRBS, O.191 or saturation engine, PRBS, O.191File playback: Plays cells as defined in a file. Two file types: ASCII / binary (Snoop; expects IP packets, will encapsulate with AAL5)Saturation engine: Provides AAL0 background traf-fic. Simulates multiple VCs. User programs a VPI / VCI range / GFC / PT / CLP / fill byte payloadO.191:Single VC with CRC, times tamp, sequence number for latency and sequencing. User programs a VPI / VCI / GFC / PT / CLPPRBS: PRBS 23 or 31.User programs a VPI / VCI / GFP / PT / CLPIdle cells: To control link bandwidthSend mode: Continuous / buffer burst for file playback. Continuous / burst for O.191. Continuous for saturation engine, PRBSTransmission rate: Specified as Mbps / Quantums (back-to-back cells for file playback / saturation engine / PRBS) / %
ERROR INJECTIONSHEC: Continuous (single bit / multiple bits)
ERROR MONITORINGHEC: Single-bit correctable / single-bit uncorrectable / multi-ple-bit; HEC error. Error correction enable / disable option
STATISTICS
Port: ATM sync / bandwidth (%,Mbps, cells / s) / cell count Per connection: Up to 256 auto-detected connections. Bandwidth (%,Mbps, cells / s), cell count / CLP=1 Cells / F5 OAM cells / congestion cells / cell inter-arrival (min, max, avg)
LATENCY AND SEQUENCINGUses O.191 cellsSequencing: Cell Loss / misinserted Cell (out-of-order). Can inject errors on transmit.Times tamping: Latency (min, max, avg over test peri-od) / peak-to-peak CDV (one point)CRC: Errored cells. Can inject errors on transmit
CAPTURESTriggers: ManualFilters: All / Per-VCDisplay: HexSize: 20,000 cellsFile type: Binary (Snoop for IP packets) / ASCII
SERVICE DISRUPTION TIMEMeasurement: us resolutionStatistics: Current / Previous / Minimum / Maximum / Average / CountEvent LoggingAutomatic re-triggeringTriggers:Ethernet and Fibre Channel: LOS / PCS Sync /PRBS SyncSONET/SDH: LOS / LOF / PRBS Sync
TESTPOINT MULTI-RATE
28
ORDER INFORMATION
TS-30/170
Multi-Rate Module
N530-0130 Multi-Rate ModuleN530-0131 Multi-Rate Module with Digital Wrapper/FEC
Options
SONET / SDH portsOPT 0130-01 OC-3/12 STM-1/4OPT 0130-03 OC-48/STM-16OPT 0130-40 OC-3/12 STM-1/4 & OC-48/STM-16OPT 0130-18 ODU1 2.498Gbps Digital WrapperOPT 0130-08 ATM for SONET/SDH portsOPT 0130-09 Ethernet over SONET/SDH for SONET/SDH portsOPT 0130-30 Ethernet over PDH for SONET/SDH portsOPT 0130-32 RPR for SONET/SDH ports
GigE / Ethernet & FC portOPT 0130-10 GigE/EthernetOPT 0130-11 1/2GFCOPT 0130-42 OC-3/12/48 STM-1/4/16 & GigE/EthernetOPT 0130-43 OC-3/12/48 STM-1/4/16 &
GigE/Ethernet & 1/2GFCOPT 0130-44 OC-3/12/48 STM-1/4/16 & 1/2GFC
SFP Optical interfaces for SONET / SDH portsOPT 0130-26 OC-3/12 STM-1/4 1310 nm SFP opticssOPT 0130-27 OC-3/12 STM-1/41550 nm SFP opticsOPT 0130-16 OC-48/STM-16 1310 nm SFP opticsOPT 0130-17 OC-48/STM-16 1550 nm SFP optics
SFP Optical interfaces for GigE / Ethernet/FC portOPT 0130-05 GigE/FC 1310 nm SFP opticsOPT 0130-06 GigE/FC 1550 nm SFP opticsOPT 0130-07 GigE/FC 850 nm SFP opticsOPT 0130-12 10/100/1000BASE-T electrical SFPOPT 0130-13 100BASE-FX 1310 nm SFP optics
Accessories
OPT 022x-10 Wheeled hard travel case accepting TS-10 or TS-30 chassis
TS-10
Multi-Rate configuration
N550-0222 TS-10 with multi-rate configuration N550-0223 TS-10 with multi-rate configuration
with Digital Wrapper/FEC
Options
SONET / SDH portsOPT 0222-01 OC-3/12 STM-1/4OPT 0222-03 OC-48/STM-16OPT 0222-40 OC-3/12 STM-1/4 & OC-48/STM-16OPT 0222-18 ODU1 2.498Gbps Digital WrapperOPT 0222-08 ATM for SONET/SDH portsOPT 0222-09 Ethernet over SONET/SDH for SONET/SDH portsOPT 0222-30 Ethernet over PDH for SONET/SDH portsOPT 0222-32 RPR for SONET/SDH ports
GigE / Ethernet / FC portOPT 0222-10 GigE/EthernetOPT 0222-11 1/2GFCOPT 0222-42 OC-3/12/48 STM-1/4/16 & GigE/EthernetOPT 0222-43 OC-3/12/48 STM-1/4/16 &
GigE/Ethernet & 1/2GFCOPT 0222-44 OC-3/12/48 STM-1/4/16 & 1/2GFC
SFP Optical interfaces for SONET / SDH portsOPT 0222-26 OC-3/12 STM-1/4 1310 nm SFP opticsOPT 0222-27 OC-3/12 STM-1/4 1550 nm SFP opticsOPT 0222-16 OC-48/STM-16 1310 nm SFP opticsOPT 0222-17 OC-48/STM-16 1550 nm SFP optics
SFP Optical interfaces for GigE / Ethernet / FC portOPT 0222-05 GigE/FC 1310 nm SFP opticsOPT 0222-06 GE/FC 1550 nm SFP opticsOPT 0222-07 GE/FC 850 nm SFP opticsOPT 0222-12 10/100/100BASE-T electrical SFPOPT 0222-13 100BASE-FX 1310 nm SFP optics
TESTPOINT MULTI-RATE
29
TestPoint Group Controller
Highlights
Compliance
CSA Certificate of Compliance to CAN/ –CSA C22.2 No. 60950-1 (2003) and ANSI/UL 60950-1 (2003) with CSA Mark for Canada and USA
CSA CB Certificate of Compliance to –EN60950-1, IEC 60950-1, and National Deviations with CE Marking
Class 1 Laser Product, with compliance to –EN 60825, IEC 60825, and FDA/CDRH requirements
Provides single-point management access to the •TestPoint chassis for multiple modules from a single interface
Provides global test functions which control multiple •modules simultaneously
Provides external clocking capabilities to modules via •backplane
Offers timestamp synchronization source for one-way •latency measurements (10 Gbps Module)
Enables multi-user environment to access multiple •modules
The JDSU TestPoint Group Controller is an optional single-slot module that plugs into slot 0 of the TestPoint TS-30 and TS-170 chassis. It provides the following main functions:
Single local area network (LAN) (Static Internet Protocol [IP] or Dynamic Host Configuration −Protocol [DHCP]) access point for test system management
Enables a single IP address for an entire chassis when the TestPoint chassis contains multiple test −modules
Without the Group Controller, each module’s faceplate can be connected directly to the LAN −
Global test function capability to control testing across multiple modules within a chassis −
Synchronized test start for multiple modules −
Advanced clocking capabilities −
Expanded clocking features beyond those available on individual test modules −
Multiple external clock synchronization options −
Timing synchronization across entire chassis −
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS
30
GLOBAL TEST FUNCTIONSTest functions may be performed individually on each module or globally via the Group Controller. Global test functions include:
Providing per-slot test status (major, minor, −history indicators)Concurrent test start/stop on multiple modules −Concurrent save and restore of the test −configuration on multiple modulesEnabling and disabling of event logs on multiple −modulesConcurrent clearing of errors, events, LEDs on −multiple modulesSelectable module reset within chassis −
CLOCKINGGroup Controller clocking is distributed to modules via the chassis backplane
Clock sourcesInternal, external, or any module’s recovered clock
Internal generatorInternal accuracy ± 4.6 ppmOffset range ± 35 ppmOffset step size 0.1 ppm
External source: T1/E1/ExternalT1 100 Ohm BantamE1 75 BNCExternal 50 SMA8 kHz/1.544 MHz/2.048 MHz/5.0 MHz/10.0 MHz/19.44 MHz/ 77.76 MHz/155.52 MHz
Module recovered clockSource clock from any module’s line recovered clock
System
Connectivity and GUIRequires PC and 10/100BaseT LAN link. Static IP and DHCP (dynamic IP) are supported.GUI interface via web browser and Java plug-in. No PC client software required.TS-30/170: PC connects to modules via the Group Controller (one LAN cable) or directly to the faceplate of each moduleTS-30/170: Group Controller supports multiple concurrent users
AutomationVia Command Line Interface (CLI) ASCII commandsConnection to CLI via Telnet, socket connections, or serial portAutomation toolkits available in: Python/C/TCL/LabView/Visual Basic
Management functionsGUI installation tool provided for field software upgradesEach test module has non-volatile storage for: software loads/configuration files/event logs/test results/capture filesResult files (event logs/test results/RFC 2544 results) from test modules can be automatically transferred to the controlling PCTS-30/170: Group Controller module provides external clocking ports:T1/E1/GPS (including 10 MHz)/and other rates
TESTPOINT GROUP CONTROLLER
31
ORDER INFORMATION
Group Controller ModuleN530-0110 Group Controller Module with Clock Distribution
AccessoriesOPT 022x-10 Wheeled hard travel case accepting TS-10 or TS-30 chassis
TESTPOINT GROUP CONTROLLER
Test & Measurement Regional Sales
NORTH AMERICATEL: +1 866 228 3762FAX: +1 301 353 9216
LATIN AMERICATEL:+1 954 688-5660FAX:+1 954 3454668
ASIA PACIFICTEL: +852 2892 0990FAX: +852 2892 0770
EMEATEL: +49 7121 86 2222FAX: +49 7121 86 1222
www.jdsu.com/test
Product specifications and descriptions in this document subject to change without notice. © 2010 JDS Uniphase Corporation July 2010 30149345 003 0710 TESTPOINT.BR.TNT.TM.AE
TESTPOINT GROUP CONTROLLER