The automatic hydroponics system with myDAQ The result : The result of the automatic hydroponics system with myDAQ by transform the solution concentrate of fertilizer solution and test working control quantity of wa- ter and fertilizer by using EC sensor as the table: Conclusion and discussion 1.Get new innovation of the automatic hydroponics system with myDAQ. 2.Get the automatic hydroponics system with myDAQ efficiently. 3.Be able to take the automatic hydroponics system with myDAQ apply in teaching activity. Mr.Chaleam Bausing, Mrs. Jongol Bausing and Mr.Satapisat Kraisee, Kanthararom School, Si Sa Ket Province, Thailand Tel +6645651143 Fax +6645651532 Experiment The result of observing EC value Step 1 Testing EC value at 0.5 by us- ing buffer solution at 0.35 Water pump doesn’t work but fertilizer solution pump work until EC value is 0.5, the system will stop working. 0.5 Step 2 Testing EC value at 0.25 by using buffer solution at 0.35 Water pump works, fertilizer solution pump doesn’t work until EC value is 0.25, the system will stop working. 0.25 Step 3 Testing EC value at 0.35 by using buffer solution at 0.35 Water pump and fer- tilizer solution pump don’t work until EC value is 0.35, the system will stop working. 0.35

Upload: satapisat

Post on 12-Nov-2014

520 views

Category:

Education


2 download

DESCRIPTION

 

TRANSCRIPT

Page 1: The automatic hydroponics system with myDAQ

The automatic hydroponics system with myDAQ

The result : The result of the automatic hydroponics system with myDAQ by transform the solution concentrate of fertilizer solution and test working control quantity of wa-ter and fertilizer by using EC sensor as the table:

Conclusion and discussion 1.Get new innovation of the automatic hydroponics

system with myDAQ.

2.Get the automatic hydroponics system with myDAQ efficiently.

3.Be able to take the automatic hydroponics system with myDAQ apply in teaching activity.

Mr.Chaleam Bausing, Mrs. Jongol Bausing and Mr.Satapisat Kraisee,

Kanthararom School, Si Sa Ket Province, Thailand Tel +6645651143 Fax +6645651532

Experiment The result of observing

EC value

Step 1

Testing EC value at 0.5 by us-ing buffer solution

at 0.35

Water pump doesn’t work but fertilizer solution pump work until EC value is 0.5, the system will stop working.

0.5

Step 2

Testing EC value at 0.25 by using buffer solution

at 0.35

Water pump works, fertilizer solution pump doesn’t work until EC value is 0.25, the system will stop working.

0.25

Step 3

Testing EC value at 0.35 by using buffer solution

at 0.35

Water pump and fer-tilizer solution pump don’t work until EC value is

0.35, the system will stop working.

0.35

Page 2: The automatic hydroponics system with myDAQ

Disaster from Flooding in lately 2011 in Thailand caused many damages in hu-man life especially products on agricul-ture. Because of Flooding for a long time we need to keep up with flooding and adjust to situation that will happen in the future. Hydroponics can control factors which effect to plant growing. As a result, we get good quality of product. The procedure produces need proficiency to look after. By the way ,we take myDAQ to apply to developed the automatic hydro-ponics system with myDAQ. It ‘s very useful to agriculturists and to adjust to flood condition taking for long time.

Materials

Microcontroller Set, Water pump, Rubbers tube, Bucket, Sprout, Fertilizer N P K according to type of formula planting, Equipments to create EC sen-sor, Temperature sensor, Power supply

Background

Objective To design and create the automatic hydroponics system with myDAQ. To test the efficiency in work-ing of the automatic hydroponics system with myDAQ. To take the automatic hydro-ponics system with myDAQ for teaching activity.

Start

Time Set Check (x)

For Time>x

Read Tem, Read EC

Show Tem (0C) Show EC Meter

If EC Meter > EC

Set EC control level

PUMP CAME ON If ECMe-ter < EC

true

false

PUMP Water ON

true

All PUMP OFF

If EC Meter between

Stop

false

true

false

true

false

Procedure to testing equipment

A