the best solution for cipp american made, american support

25
The Best Solution for CIPP American Made, American Support Introducing America’s First UV Cured Fiberglass CIPP

Upload: carina

Post on 10-Jan-2016

25 views

Category:

Documents


0 download

DESCRIPTION

Introducing America’s First UV Cured Fiberglass CIPP. The Best Solution for CIPP American Made, American Support. Strength. Test Results 4MM 8” StreamlinerUV ™ Liner Flexural strength: 52,000 PSI 50 year flexural strength: 33,840 PSI (65% retention) Flexural modulus: 1,700,000 PSI - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: The Best Solution for CIPP American Made, American Support

The Best Solution for CIPP

American Made, American Support

Introducing America’s FirstUV Cured Fiberglass CIPP

Page 2: The Best Solution for CIPP American Made, American Support

Test Results4MM 8” StreamlinerUV™ LinerFlexural strength: 52,000 PSI50 year flexural strength: 33,840 PSI (65% retention)

Flexural modulus: 1,700,000 PSI50 year flexural modulus: 1,160,240 PSI (68% retention)

3MM 8” StreamlinerUV™ LinerFlexural strength: 47,000 PSIFlexural modulus: 1,350,000 PSI

STRENGTH

Page 3: The Best Solution for CIPP American Made, American Support

PERFORMANCE

Water Tight: 100% leak proof*No Shrinkage: 0.0% loss*

Thin Wall: From 3mmCured: Ultra Violet Light

Curing Speed: 7.5ft per minute (8” )Laterals: No seals or grouting required

Flow: Hazen-Williams C=150

*2009 IKT Liner Report, (Institute for Underground Infrastructure)

Page 4: The Best Solution for CIPP American Made, American Support

LINER CONSTRUCTION

Polyester outer containment and protection foil.

Chemical and temperature resistant 7 layer polyethylene/polyamine inner containment foil.

Multiple layers of high quality E-CR fiberglass. The fiberglass layers are saturated with polyester or vinyl ester resins during manufacturing.

Translucent UV resistant outer foil.

Page 5: The Best Solution for CIPP American Made, American Support

LINER CONSTRUCTION

Clear inner foil is removed.

Outer foil remains in the pipe after curing.

Proprietary resin “jelling” maintains consistent wall thickness during storage, shipping and installation.

Page 6: The Best Solution for CIPP American Made, American Support

Line is bypassed Upstream manhole is plugged

LINER INSTALLATION

Line is cleaned and pre-videoed Rope pulled in during pre-video

Page 7: The Best Solution for CIPP American Made, American Support

Pre-liner pulled through the pipe with rope inserted from pre-video

LINER INSTALLATION

Second rope is pulled through pipe with pre-liner.

Page 8: The Best Solution for CIPP American Made, American Support

Liner is delivered to the job site Liner is pulled in place by a winch

LINER INSTALLATION

Page 9: The Best Solution for CIPP American Made, American Support

Safety sleeves are inserted on liner End caps are installed on each end of

the liner

LINER INSTALLATION Liner is inflated and calibrated at 8psi Light Train is inserted and pressure is

restored

Page 10: The Best Solution for CIPP American Made, American Support

Light Train Camera is activated Light Train is manually pulled and

uncured liner is video inspected

LINER INSTALLATION Any installation issues are

resolved and video is archived.

Page 11: The Best Solution for CIPP American Made, American Support

Light Train UV lamps are activated Light Train is pulled via computer

control through the liner.

LINER CURING Speed, temperature and pressure

are monitored throughout the curing process.

Page 12: The Best Solution for CIPP American Made, American Support

LINER CURING

Page 13: The Best Solution for CIPP American Made, American Support

COMPARISONCURING

UVFG

FELT

ULTRA VIOLET LIGHT STEAM OR HOT WATER

Page 14: The Best Solution for CIPP American Made, American Support

Crew S

ize3

to 5

Cure

Tim

e

7ft p

er m

in.

Cool T

ime

0

Runs

per D

ay

2 to

3

Job

Site T

ime

2.5

Hours

Crew

Size

5 to 6

Cure Tim

e

2.5+ Hours

Cool Tim

e

45 to 60 min

Runs per D

ay

1 to 2Job S

ite Time

5 Hours

COMPARISONINSTALLATION

UVFG

FELT

Page 15: The Best Solution for CIPP American Made, American Support

COMPARISONSTRENGTH

•52,000 PSIFlexural Strength

•1.7M PSIFlexural Modulus

•E-CR GlassMaterial

•9,300 PSIFlexural Strength

•448,000 PSIFlexural Modulus

•Needled FeltMaterial

UVFG

FELT

Page 16: The Best Solution for CIPP American Made, American Support

UVFG

FELT

COMPARISONLONGEVITY

Year 1 Year 25 Year 500

200,000400,000600,000800,000

1,000,0001,200,0001,400,0001,600,0001,800,000

1,700,000

1,400,000

1,160,240

448,000350,000

260,000

UVFG Flex Modulus*Felt Flex Modulus**

* D2990 test results StreamLiner UV* *Insituform

Page 17: The Best Solution for CIPP American Made, American Support

*2009 IKT Liner Report, (Institute for Underground Infrastructure)

100% water tight* 63% water tight *

COMPARISONWATER TIGHTNESS

UVFG

FELT

Page 18: The Best Solution for CIPP American Made, American Support

COMPARISONSHRINKAGE

UVFG

FELT

0.0% ≤5%

Page 19: The Best Solution for CIPP American Made, American Support

UVFG

FELT

COMPARISONINNER DIAMETER

8” 3MM Liner0% Shrinkage

Loss of I.D.

5.8%

8” 6MM Liner3% Shrinkage

Loss of I.D.

15.8%

Page 20: The Best Solution for CIPP American Made, American Support

BID RESULTS

UVFG Felt Felt $-

$500,000.00

$1,000,000.00

$1,500,000.00

$2,000,000.00 $897,895.0

0

$1,217,528

.00

$1,547,106

.00

Project 2842755 -- Sanitary Sewer Rehabilita-tion Homer, AK

Page 21: The Best Solution for CIPP American Made, American Support

BID RESULTS

UVFG Felt Felt $-

$2,000,000.00 $4,000,000.00 $6,000,000.00 $8,000,000.00

$10,000,000.00 $4,580,000

.00

$6,990,000

.00

$8,640,000

.00

Brandywine Hundred 2009 CIPPL Sewer Rehabilitation New Castle, DE

Page 22: The Best Solution for CIPP American Made, American Support

BID RESULTS

UVFG Felt Felt $-

$500,000.00 $1,000,000.00 $1,500,000.00 $2,000,000.00 $2,500,000.00

$1,596,656

.00

$1,655,348

.00

$2,072,066

.00

Sewer Pipeline Rehabilitation Phase J1BCity of San Diego

Page 23: The Best Solution for CIPP American Made, American Support

Flexural Mod 448K PSIFlexural Strength of 9300 PSINo pre-cure videosThicker wall and reduced flow

Liner shown to shrinkLiner shown to leakMust seal lateral connectionsMust deal with odor and styrene

and you were being presented with…

Would you even consider felt technology?

What if today's standards were…No ShrinkageNo leakingNo Lateral Seals neededNo odor or curing by-products

Flexural Mod of 1.7M PSIFlexural Strength 52K PSIMultiple curing videosThinner liner and greater flow

Page 24: The Best Solution for CIPP American Made, American Support

NEXT STEPS

Review the Streamliner UV specification doc

Recommend UV fiberglass as an approved material

Page 25: The Best Solution for CIPP American Made, American Support