the city of vincent - g.1 d.1 a...to structural eng's requirements with plasterb'd lining to...
TRANSCRIPT
-
1:20
1:8
1:8
1:4
1:4
1:8
STA
IRS
1
LIFT(RES)
UP
STOREU. 31CONC.
STOREU. 30CONC.
STOREU. 29CONC.
STOREU. 28CONC.
STOREU. 22CONC.
STOREU. 23CONC.
ST.U.24CONC.
STOREU. 25CONC.
STOREU. 26CONC.
STOREU. 20CONC.
STOREU. 32CONC.
CAR PARK17 BAYSCONCRETE
CAR PARK9 BAYSCONCRETE
ST.U. 21CONC.
STOREU. 33CONC.
29
29
23
24
25
26
22
21
20
30
30
V
V
28
28
2736VV
19
31
V
2 X BIKES
GC D F HA B IEA.1
C.1 C.2G.1
G.2 G.3 I.1D.1
4100 550 1965 1960 3175 1400 6080 625 905 4570 1050 1025 3075 4475 2100 1960 940 6175
BASEMENT FLOOR PLAN
RAMP UP
1:8
1:20
RAMP DOWN
GRID
BOUNDARY
BUILDING SETOUT
PARKING
PARKING
PARKING
GRI
D
BOUN
DA
RY
BUIL
DIN
G S
ETO
UT
PARK
ING
PARK
ING
PARK
ING
PARK
ING
PARK
ING
PARK
ING
PARK
ING
PARK
ING
PARK
ING
GRI
DS
46130
2824
5O
VER
ALL
BUI
LDIN
G
2092
019
80EL
ECTR
ICA
L24
00C
AR
BAY
2400
CA
R BA
Y
350
2400
CA
R BA
Y24
00C
AR
BAY
2400
CA
R BA
Y
350
2400
CA
R BA
Y
300
100
3300
STO
RE U
.26
200
5700
RAM
P60
025
1870
0A
ISLE
100
2200
STO
RES
5600
AIS
LE17
0027
50C
AR
BAY
2750
CA
R BA
Y27
00C
AR
BAY
200
4500
STA
IRS
200
900
200
6000
AIS
LE
100
1500
STO
RE
100
2700
CA
R BA
Y27
0020
0
20 20 20
25 25 25
600 5400PART RAMP 1:20
2000RAMP 1:8
4150RAMP 1:4
2000RAMP 1:8
6630AISLE
350 2400CAR BAY
2400CAR BAY
2400CAR BAY
350 2400CAR BAY
5600 600
2400SET BACK
1580STORE 26
100 2050STORE 25
100 1770STORE 24
100 1000HALL
100 2210STORE
100 2240STORE
2001200
STAIRS
200 7050CAR BAYS WALL
18180AISLE
5400CAR BAYS
5400CAR BAYS
6000AISLE
5400CAR BAYS
100 1900STORE
100 5130 100 1500STORE
100 5400CAR BAYS
6000AISLE
1.1
3.1
5
1
2
4
2.1
1.2
1.3
4.1
1.4
2.2
3.2
100
1000
1000
1980
2450
4665
4260
3890
3045
3980
595
410
775
95
ELEV.A202
4
ELEV. 3A201A301
A
A301A
ELEV
.1
A20
1
A302C
A302B
A302C
A302B
ELEV
.A
2012
2025
2820
0
43730OVERALL BUILDING
4800
CA
R BA
Y27
00C
AR
BAY
350
2700
CA
R BA
Y24
00C
AR
BAY
2700
CA
R BA
Y
350
2700
CA
R BA
Y24
00C
AR
BAY
6300
2450
2400
CA
R BA
Y24
00C
AR
BAY
2400
CA
R BA
Y63
50A
ISLE
5400
CA
R BA
Y
5400
CA
R BA
Y10
015
60ST
ORE
100
2640
STO
RE
100
1150
0A
ISLE
CO
RE -
REF
TO A
100
1130
0A
ISLE
2020
060
00A
ISLE
1100
100
2100
STO
RE
100
2100
STO
RE
100
2100
STO
RE
100
2100
STO
RE
200
2700
2700
200
5700
RAM
P60
025
2025
2025
2025
2025
600 5400CAR BAYS
6000AISLE
5400CAR BAYS
1001900
STORES
1001280
PASSAGECORE - REF A100
1005400
CAR BAYS6000AISLE
5400CAR BAYS
600
2500 100 2800COMMS
2700CAR BAY
31730AISLE
PARKING
PARKING
PARKING
12.050 F.L
12.050 F.L
2400SET BACK
MSB. REFER ELECTRICALSERVICES DOCUMENTATION.
UP
1:8
1:8
1:4
1:4
STAIRS 2
32 33
2400CAR BAY
2950CAR BAY
FULL HT WALL
AUTOMATIC ROLLERDOOR OVER
25
2200STORE
100
ACCESS TO STORMWATER TANK UNDERRAMP
MAINTAIN MINIMUM HEADHEIGHT ABOVE ACCESSIBLEPARKING BAY IN ACCORDANCEWITH AS/NZS 2890.6-2009(2500mm)
2000RAMP 1:8
4450RAMP 1:4
FR
FR
D05 D05 D05 D05 D05
D05
D05
D05
D05
D05
D05
D05
D07
D07
WATER TANK &PUMPS UNDERRAMP
LIFT(SHORT STAY)
D05
3000TANK
PRECAST WALL
3000
TA
NK
PROVIDE RECESS TOFULL HT OF PANELS
FOR GROUT FILLING
ANGLE TOP OFPRECAST TANK WALLSTO SIT FLUSH WITH 1:20
RAMP SOFFIT
ANGLE TOP OFPRECAST TANK WALLSTO SIT FLUSH WITH 1:20RAMP SOFFITENLARGED DETAIL
D05
300
2800
BAY
19
D05
7 X BIKES2 X BIKES
Project Name
Project Number
Scale
Title
Drawing Number
Date
Issue
DO NOT SCALE FROM THIS DRAWING.THIS DRAWING IS FOR READING PURPOSES ONLY.
Issue. Issue Description.By Date.
FR = FIRE RATED DOOR _/60/30
P MWA ISSUE FOR BUILDING PERMIT 11/04/16
STRUCTURAL ELEMENT - PRECAST CONC -PROVIDE LINING TO ELEMENTAPPROPRIATE TO LOCATION/SITUATION TOMATCH ADJACENT FINISHES TO ACHIEVEFRL 120/60/30
PARTY WALL - NON LOAD BEARING -X2 ROWS OF STEEL STUDS @ 600mm CTSMAX WITH 20mm ROW GAP WITHINSULATION & WALL LININGS TO ACHIEVE90/90/90 & Rw+Ctr >50. WALLSSEPARATING SHOPS 34 & 35 FROM ENTRYLOBBY TO ACHIEVE 120/120/120
STUD WALL - NON LOAD BEARING96mm HEAVY DUTY STEEL FRAMEWORK.AIRCELL INSULATION WITH 16mmFYRCHECK INTERNAL & 9mm CFC SHEETEXTERNAL LINING WITH VILLA SAND FINISH.WALLS TO ACHIEVE Rw+Ctr >50, & WHEREWITHIN 3m OF SIDE BOUNDARY OR ARE ASOLE OCCUPANCY UNIT WALL TO ACOMMON CORRIDOR, LOBBY ORSTAIRWELL; TO ACHIEVE FRL -/90/90
150 PRECAST CONC WALL -TO STRUCTURAL ENGINEERSREQUIREMENTS WITH BULK + FOIL SIDEDINSULATION & ANTI GLARE WITHPLASTERB'D LINING TO INTERNAL SIDE.WALLS TO ACHIEVE FRL 120/60/30 &Rw+Ctr >50.
250 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTS.WALLS TO ACHIEVE FRL 120/60/30
PACKING -PROVIDE PACKING & LINING TO WALL TOBE FLUSH WITH & TO MATCH ADJACENTWALLS FINISHES
NOTES:
1. BUILDER TO CHECK ALL DIMENSIONS ON SITE PRIOR TOCOMMENCING CONSTRUCTION.
2. ARCHITECTURAL DRAWINGS ARE TO BE READ INCONJUNCTION WITH ALL RELEVANT CONSULTANTSDRAWINGS.
3. ALL BUILDING WORKS TO BE EXECUTED INACCORDANCE WITH AUSTRALIAN STANDARDS,BUILDING CODE OF AUSTRALIA & LOCAL & REGULATORYAUTHORITIES.
4. BUILDER TO NOTIFY ARCHITECT IMMEDIATELY OF ANYSERVICE LOCATION DISCREPANCIES OR CLASHES ONSITE.
STUD WALL - INTERNAL PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm PLASTERB'DLINING EACH SIDE & PAINT FINISH
STUD WALL - WET AREA PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm WATER RESISTANTPLASTERB'D LINING & PAINT FINISH, ORVILLA BOARD & TILES TO WET AREA SIDE.
200 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTSWITH PLASTERB'D LINING TO INTERNALSIDE (TO UNITS). WALLS TO ACHIEVE FRL120/60/30
STORE ROOMS - STUD WALL -STUD FRAMED WALLS TO 2100 HT WITHCHAINWIRE MESH & METAL FRAMINGABOVE
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
TYPE 7
TYPE 8
TYPE 9
TYPE 10
BALCONY PARTITIONS - STUD WALL -STEEL STUD FRAMED WALLS TO FULL HTWITH 1X CFC/BLUE BOARD LINING BOTHSIDES & ACRATEX FINISHTYPE 11
TYPE 12
LIFT/STAIR CORE - AFS WALL150 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISHTYPE 13
LIFT/STAIR CORE - AFS WALL262 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISH
Q MWA 2ND LIFT + SHORT STAY AMENDMENTS 09/05/16
R MWA 2ND LIFT + SHORT STAY AMENDMENTS 16/05/16
S MWA ISSUE FOR CONSTRUCTION 21/06/16
T MWA UNIT NUMBERS AMENDED 12/07/16
U MWA AS BUILT 22/08/17
V MWA AS BUILT CONDITIONS 03/10/17
Z1 MWA AS BUILT CONDITIONS 17/11/17
AutoCAD SHX Text283 - 285 VINCENT STREET
AutoCAD SHX TextAUG 2016
AutoCAD SHX Text1:100
AutoCAD SHX TextZ1
AutoCAD SHX TextA101
AutoCAD SHX Text16.04
AutoCAD SHX TextBASEMENT FLOOR PLAN
AutoCAD SHX TextLEEDERVILLE
AutoCAD SHX TextMIXED-USE DEVELOPMENT
-
1.1
3.1
5
1
2
4
2.1
1.2
1.3
4.1
1.4
2.2
3.2
100
1000
1000
1980
2450
4665
4260
3890
3045
3980
595
410
775
95
1:20
1:20
1:8
1:8
1:4
1:4
RAMP UP - 1:4
RAMP DOWN - 1:4 1:8
1:8
RAMP UP - 1:16
(UNIT 34)
LOBBYTILES
STAIRS 1
ACCESSTOILET
TILES
UP
DN
RESIDENTIALBIN STORE
CONCRETE
COMM.BIN STORE
CONCRETE
STORE U. 4
CONCRETE
STORE U. 10
CONCRETE
STORE U. 11
CONCRETE
STORE U. 3
CONCRETE
STORE U. 2
CONCRETE
STORE U. 1
CONCRETE
STORE U. 5
CONCRETE
STORE U. 6
CONCRETE
STOREU. 7
CONCRETE
SHOPUNIT 35CONCRETE
CAR PARK13 BAYSCONCRETE
89 7 6 5 4 3 2 1
V V1110
6 X
BIKE
S
5 BIKE RACKS
GROUND FLOOR PLAN
EOTTILES
BASEMENT RAMPCONCRETE
NOM. 1500Hx2000Lx600DENCLOSURE TO RECEIVE FIRE
BOOSTER & HYDRANT SET.
600 HIGH RAISEDMASONRY PLANTER.
600 HIGH RAISEDMASONRY PLANTER.
ENTRYTILES
FORECOURTTILES
PASSAGETILES
GRID
BOUNDARY
BUILDING SETOUT
PARKING
ROOMS
ROOMS
ROOMS
ROOMS
INTERNAL OPENINGS
GRI
D
BOUN
DA
RY
SETO
UT
OPE
NIN
GS
ROO
MS
ROO
MS
ROO
MS
ROO
MS
ROO
MS
ROO
MS
ROO
MS
OPE
NIN
GS
GRI
D
46130BOUNDARY
2824
5BO
UND
ARY
2025
2820
0
36130OVERALL BUILDING
2025
RAMPCONCRETE
11950PART RAMP TO BASEMENT
200 2730 2400CAR BAY
2400CAR BAY
350 2400CAR BAY
2400CAR BAY
2400CAR BAY
350 2400CAR BAY
2400CAR BAY
2400CAR BAY
350 2400CAR BAY
2400 200
4000SETBACK
6000SETBACK
1850 2000 MINFIRE
BOOSTER
195 7710SHOP - UNIT 34
245 1730 23650RAMP / AISLE
2600AISLE
3880LOBBY
CORE - REF A100 1125PASS.
100 2700CAR BAY
2700CAR BAY
1650 2400CAR BAY
2400CAR BAY
3175 200
5325 200 15330LOBBY
4000
195 14045SHOP - UNIT 35
4000SETBACK
140 2475PASSAGE
1525 3445OPENING
11885
GC D F HA B IEA.1
C.1 C.2G.1
G.2 G.3 I.1D.1
4100 550 1965 1960 3175 1400 6080 625 905 4570 1050 1025 3075 4475 2100 1960 940 617520
021
00PA
SSA
GE
5100
OPE
NIN
G90
010
00O
PEN
.11
1012
10O
PEN
.
590
1790
OPE
NIN
G16
5097
0O
PEN
.39
50O
PEN
ING
580
750
5800
OPE
NIN
G20
0
9610
SHO
P - U
NIT
3518
00LO
BBY
7500
SHO
P - U
NIT
34
200
5700
RAM
P
2530
0
400
14.900 F.L
14.900 F.L
14.900 F.L
14.9
00 F
.L
1800
PASS
AG
E150
6400
CO
MM
. BIN
STO
RE
150
3360
SHO
P - U
NIT
3519
50ST
ORE
U.3
4
200
6100
AIS
LE56
00C
AR
BAYS
100
2508
AC
CES
S W
C
100
3900
LOBB
Y
PLANTER 2
ELECTRICAL AND COMMS TOELECTRICAL CONSULTANTS
REQUIREMENTS.
BANK OF WALL MOUNDED WATERMETERS, NOM. 4500 x 2000 INACCORDANCE WITHHYDRAULIC DRAWINGS.
4000SETBACK
19512550
SHOP - UNIT 352700
ACCESS WC
1001095PASS.
CORE - REF A100 1900STORE
1002525
STORE
1002525
STORE
1002525
STORE
1002525
STORE
1002525
STORE
200
10800SHOP - UNIT 35
1001125PASS.
2900COMM. BIN STORE
6805RESIDENTIAL BIN STORE
100 2350STORE
1001230PASS.
20011200RAMP
6000SETBACK
20 20 20 20
100
200
1800
PASS
AG
E
150
6450
RESI
DEN
TIAL
BIN
STO
RE
100
7400
LOBB
Y
200
6100
AIS
LE56
00C
AR
BAYS
200
4450
RESI
DEN
TIAL
BIN
STO
REC
ORE
- RE
FER
TO A
100
200
1710
STO
RE
100
1710
STO
RE
100
1710
STO
RE
100
2150
STO
RE
100
1020
PASS
.
100
5400
CA
R BA
YS55
00RA
MP
200
1300
PASS
.
100
1600
STO
RE
2025
2025
2025
ELEV.A202
4
ELEV. 3A201A301
A
A301A
2
3
5
4
1
2.3
3.2
7025
6225
5675
7025
1325
775
100
95 2034
0047
50O
PEN
ING
350
6200
OPE
NIN
G75
0O
P.80
037
50O
PEN
ING
500
2700
CLE
AN
ERS
STO
RE
100
8900
25
BUILDING OVERSHOWN DASHED.
15.825 F.L
14.900 F.L
16.4
50 F
.L
STA
IRS
4
6000
AIS
LE
LETT
ER B
OXE
S
EXHAUST RISER WITHMESH SHROUD. & IVY
CREEPER
LV KIOSK1400 X 800W
WASHPOINT
SC1
GL7
GL6
GL5
GL4
GL1
GL3
SC4
GL8
ACCESS TOILET & SHOWERTO COMPLY WITH AS1428.
PROVIDE KERB RAIL TO EXTENTREQUIRED TO SHEILD BASEMENT
WALL PROTRUSION TO RAMP.
PLANTER
WASHPOINT
FIRE BOOSTER &HYDRANT SET ACCESSEDFROM HARDSTAND SIDE
HARDSTANDCONCRETE
FIRE RATED WALL BETWEENBINS STORES, TOILET & LOBBY
TO ACHIEVE -/120/120FR
FR
FR
FR
D07
D07
D07
D10 D10
D08
D09
D05D05 D05 D05 D05 D05
D05
D05
D05
D07
LIFT(RES)
LIFT(SHORT STAY)
STAIR 3
SHORT -STAYSHORT -STAYSHORT -STAYSHORT -STAYSHORT -STAYSHORT -STAYSHORT -STAYSHORT -STAYSHORT -STAY
SHORT -STAY SHORT -STAYRECEPTIONSHORT-STAY
SHORT-STAY &
UP
UP
110m2
58m2
BI-FOLD DOORS TO OPENTENANCY TO PASSAGE
BI-FOLD DOOR TO OPENTENANCY TO FORECOURT
RL 15.390 RL 15.350
RL 15.250
RL 14.850
RL 15.120
RL 15.000
FOO
TPA
TH
VER
GE
(GRA
SS)
VER
GE
(GRA
SS)
RL 1
5.13
5
RL 15.135
RL 15.100
RL 14.870
RL 14.950
RL 15.300
RL 14.670
RL 14.720
RL 14.870
RL 14.870
RL 14.890
RL 14.890RL 14.890
RL 14.630
RL 14.890
RL 14.680
RL 14.890
RL 14.850RL 14.750
RL 14.850
RL 14.850
1160
12701600
UP
UP
SLIDING SECURITY GATE.ALUMINIUM BLADES & FRAMING- POWDER COAT FINISH
3 x
BIKE
S
SLIDING SECURITY GATE.ALUMINIUM BLADES &FRAMING - POLISHEDANODISED FINISH
SLIDING SECURITY GATE.ALUMINIUM BLADES &FRAMING - POLISHEDANODISED FINISH
REFER TO LANDSCAPINGPLAN A700 FOR PLANTSPECIES ALLOCATION
REFER TO LANDSCAPINGPLAN A700 FOR PLANTSPECIES ALLOCATION
Project Name
Project Number
Scale
Title
Drawing Number
Date
Issue
DO NOT SCALE FROM THIS DRAWING.THIS DRAWING IS FOR READING PURPOSES ONLY.
Issue. Issue Description.By Date.
R MWA 2ND LIFT + SHORT STAY AMENDMENTS 16/05/16
FR = FIRE RATED DOOR _/60/30
STRUCTURAL ELEMENT - PRECAST CONC -PROVIDE LINING TO ELEMENTAPPROPRIATE TO LOCATION/SITUATION TOMATCH ADJACENT FINISHES TO ACHIEVEFRL 120/60/30
PARTY WALL - NON LOAD BEARING -X2 ROWS OF STEEL STUDS @ 600mm CTSMAX WITH 20mm ROW GAP WITHINSULATION & WALL LININGS TO ACHIEVE90/90/90 & Rw+Ctr >50. WALLSSEPARATING SHOPS 34 & 35 FROM ENTRYLOBBY TO ACHIEVE 120/120/120
STUD WALL - NON LOAD BEARING96mm HEAVY DUTY STEEL FRAMEWORK.AIRCELL INSULATION WITH 16mmFYRCHECK INTERNAL & 9mm CFC SHEETEXTERNAL LINING WITH VILLA SAND FINISH.WALLS TO ACHIEVE Rw+Ctr >50, & WHEREWITHIN 3m OF SIDE BOUNDARY OR ARE ASOLE OCCUPANCY UNIT WALL TO ACOMMON CORRIDOR, LOBBY ORSTAIRWELL; TO ACHIEVE FRL -/90/90
150 PRECAST CONC WALL -TO STRUCTURAL ENGINEERSREQUIREMENTS WITH BULK + FOIL SIDEDINSULATION & ANTI GLARE WITHPLASTERB'D LINING TO INTERNAL SIDE.WALLS TO ACHIEVE FRL 120/60/30 &Rw+Ctr >50.
250 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTS.WALLS TO ACHIEVE FRL 120/60/30
PACKING -PROVIDE PACKING & LINING TO WALL TOBE FLUSH WITH & TO MATCH ADJACENTWALLS FINISHES
NOTES:
1. BUILDER TO CHECK ALL DIMENSIONS ON SITE PRIOR TOCOMMENCING CONSTRUCTION.
2. ARCHITECTURAL DRAWINGS ARE TO BE READ INCONJUNCTION WITH ALL RELEVANT CONSULTANTSDRAWINGS.
3. ALL BUILDING WORKS TO BE EXECUTED INACCORDANCE WITH AUSTRALIAN STANDARDS,BUILDING CODE OF AUSTRALIA & LOCAL & REGULATORYAUTHORITIES.
4. BUILDER TO NOTIFY ARCHITECT IMMEDIATELY OF ANYSERVICE LOCATION DISCREPANCIES OR CLASHES ONSITE.
STUD WALL - INTERNAL PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm PLASTERB'DLINING EACH SIDE & PAINT FINISH
STUD WALL - WET AREA PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm WATER RESISTANTPLASTERB'D LINING & PAINT FINISH, ORVILLA BOARD & TILES TO WET AREA SIDE.
200 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTSWITH PLASTERB'D LINING TO INTERNALSIDE (TO UNITS). WALLS TO ACHIEVE FRL120/60/30
STORE ROOMS - STUD WALL -STUD FRAMED WALLS TO 2100 HT WITHCHAINWIRE MESH & METAL FRAMINGABOVE
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
TYPE 7
TYPE 8
TYPE 9
TYPE 10
BALCONY PARTITIONS - STUD WALL -STEEL STUD FRAMED WALLS TO FULL HTWITH 1X CFC/BLUE BOARD LINING BOTHSIDES & ACRATEX FINISHTYPE 11
TYPE 12
LIFT/STAIR CORE - AFS WALL150 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISHTYPE 13
LIFT/STAIR CORE - AFS WALL262 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISH
S MWA ISSUE FOR CONSTRUCTION 21/06/16
T MWA UNIT NUMBERS AMENDED 12/07/16
U MWA STAIR 3 + ACCESS TOILET AMENDED 04/08/16
V MWA STAIR 1 AMENDED (LANDING RISERS MOVED) 03/09/16
W MWA AS BUILT 22/08/17
X MWA AS BUILT CONDITIONS 03/10/17
Z1 MWA AS BUILT CONDITIONS 17/11/17
AutoCAD SHX Text283 - 285 VINCENT STREET
AutoCAD SHX TextAUG 2017
AutoCAD SHX Text1:100
AutoCAD SHX TextZ1
AutoCAD SHX TextA102
AutoCAD SHX Text16.04
AutoCAD SHX TextGROUND FLOOR PLAN
AutoCAD SHX TextLEEDERVILLE
AutoCAD SHX TextMIXED-USE DEVELOPMENT
-
TENANCYUNIT 36CONCRETE
LOBBYTILES
UP
UNIT 37STORE ROOM
CONCRETE
TENANCYUNIT 37CONCRETE
CAR PARK12 BAYSCONCRETE
18 17 16 15 14 13 12
3736V
3736
ELEV.A202
4
ELEV. 3A201A301
A
A301A
2
3
5
4
1
2.3
3.2
7025
6225
5675
7025
1325
775
100
95
ELEV
.1
A20
1
A302C
A302B
A302C
A302B
ELEV
.A
2012
FIRST FLOOR PLAN
18.900 F.L
18.900 F.L
STOREU. 12CONC.
STOREU. 13CONC.
STOREU. 8
CONC.
STOREU. 18CONC.
STOREU. 17CONC.
STOREU. 9
CONC.
STOREU. 19CONC.
STOREU. 27CONC.
STOREU. 16CONC.
STOREU. 15CONC.
STOREU. 14CONC.
ELECTRICAL AND COMMS TOELECTRICAL CONSULTANTSREQUIREMENTS.
1.1
3.1
5
1
2
4
2.1
1.2
1.3
4.1
1.4
2.2
3.2
100
1000
1000
1980
2450
4665
4260
3890
3045
3980
595
410
775
95
GRID
BOUNDARY
BUILDING SETOUT
ROOMS
ROOMS
ROOMS
GRI
D
BOUN
DA
RY
SETO
UT
OPE
NIN
GS
ROO
MS
ROO
MS
ROO
MS
ROO
MS
ROO
MS
ROO
MS
ROO
MS
ROO
MS
ROO
MS
OPE
NIN
GS
GRI
DS
46130BOUNDARY
2824
5BO
UND
ARY
2025
2820
0
38130OVERALL BUILDING
25
ROOMS
ROOMS
ROOMS
4890
2400CAR BAY
2400CAR BAY
2400CAR BAY
350 2400CAR BAY
2400CAR BAY
2400CAR BAY
350 2400CAR BAY
750
4000SETBACK
4000SETBACK
27230AISLE
6130LOBBY
CORE - REF A100 1000PASS.
1001500STORE
2400CAR BAY
2700CAR BAY
2700CAR BAY
2100
250
GC D F HA B IEA.1
C.1 C.2G.1
G.2 G.3 I.1D.1
4100 550 1965 1960 3175 1400 6080 625 905 4570 1050 1025 3075 4475 2100 1960 940 6175
200
25
7960
TEN
AN
CY
- UN
IT 36
4000SETBACK
CORE - REF A100 1500STORE
1002650
STORE
1002700
CAR BAYS2700
CAR BAYS
7630TENANCY - UNIT 37
100 1700STORE
100
4000SETBACK
20 20 20 20
200
2670
WC
200
6100
AIS
LE56
00C
AR
BAYS
200
1800
200
1670
STO
RE
100
2400
STO
RE
100
1500
STO
RE100
1400
PASS
.54
00C
AR
BAYS
5500
RAM
P
200
2850
STO
RE
2025
2025
2025
20
3950
4690
OPE
NIN
G58
0023
60O
PEN
ING
25
EQ27
70O
PEN
ING
3000BALCONY
200
200650 2244
PASS.1700
STORE
100 1700STORE
2420STORE
2420STORE
2595STORE
100 100
BALCONYTILES
BALCONYTILES N
OM
. 143
00RA
MP
20 20
1225
PASS
.
100
1050
5TA
ND
EM C
AR
BAYS
250 1
620
STO
RE14
330
PASS
.90
024
00ST
ORE
S
250
25 25 2520
590
4808
OPE
NIN
G59
048
20O
PEN
ING
590
3000BALCONY
7130TENANCY - UNIT 35 & PART 36
5500RAMP
1001700
STORE
1001700
STORE
6100
AIS
LE
5788
LOBB
Y
1950
STO
RE
350
EQ27
70O
PEN
ING
EQ27
70O
PEN
ING
2770
OPE
NIN
G83
0EQ
2770
OPE
NIN
GEQ
2770
OPE
NIN
GEQ
2770
OPE
NIN
G27
70O
PEN
ING
350
2825STORE
1650
UNIT 36STORE ROOM
CONCRETE
GL11
ULTRABONDFRAME TO
FEATURE WALLOPENING
ULTRABONDFRAME TO
FEATURE WALLOPENING
STEEL FRAMED WALLWITH CFC LINING &
BRICK TILES OVER
STEEL FRAMED WALLWITH CFC LINING &
BRICK TILES OVER
STEEL FRAMEDBALUSTRADE WITH
CFC LINING & BRICKTILES OVER
FR
FR
FR
AA402
D07
D07
D07
D09
D05
D05
D05 D05 D05
D05 D05 D05
D05
D05 D05
LIFT(RES)
LIFT(SHORT STAY)
SHORT -STAYSHORT -STAYSHORT -STAYSHORT -STAYSHORT -STAYSHORT -STAYSHORT -STAY
PLUMBINGIN CAVITY
D07
FR
116m2
103m2
VOID TO BELOW
FW
FW
FW
2700
CRI
TICA
L
2200ACCESS TOILET
3640
6100
900
7110
1383
0TE
NA
NC
Y - U
NIT
3613
820
TEN
AN
CY
- UN
IT 36
4140
4200
8270STORE - UNIT 37
2070
3 X
BIKE
S
Project Name
Project Number
Scale
Title
Drawing Number
Date
Issue
DO NOT SCALE FROM THIS DRAWING.THIS DRAWING IS FOR READING PURPOSES ONLY.
Issue. Issue Description.By Date.
FR = FIRE RATED DOOR _/60/30
STRUCTURAL ELEMENT - PRECAST CONC -PROVIDE LINING TO ELEMENTAPPROPRIATE TO LOCATION/SITUATION TOMATCH ADJACENT FINISHES TO ACHIEVEFRL 120/60/30
PARTY WALL - NON LOAD BEARING -X2 ROWS OF STEEL STUDS @ 600mm CTSMAX WITH 20mm ROW GAP WITHINSULATION & WALL LININGS TO ACHIEVE90/90/90 & Rw+Ctr >50. WALLSSEPARATING SHOPS 34 & 35 FROM ENTRYLOBBY TO ACHIEVE 120/120/120
STUD WALL - NON LOAD BEARING96mm HEAVY DUTY STEEL FRAMEWORK.AIRCELL INSULATION WITH 16mmFYRCHECK INTERNAL & 9mm CFC SHEETEXTERNAL LINING WITH VILLA SAND FINISH.WALLS TO ACHIEVE Rw+Ctr >50, & WHEREWITHIN 3m OF SIDE BOUNDARY OR ARE ASOLE OCCUPANCY UNIT WALL TO ACOMMON CORRIDOR, LOBBY ORSTAIRWELL; TO ACHIEVE FRL -/90/90
150 PRECAST CONC WALL -TO STRUCTURAL ENGINEERSREQUIREMENTS WITH BULK + FOIL SIDEDINSULATION & ANTI GLARE WITHPLASTERB'D LINING TO INTERNAL SIDE.WALLS TO ACHIEVE FRL 120/60/30 &Rw+Ctr >50.
250 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTS.WALLS TO ACHIEVE FRL 120/60/30
PACKING -PROVIDE PACKING & LINING TO WALL TOBE FLUSH WITH & TO MATCH ADJACENTWALLS FINISHES
NOTES:
1. BUILDER TO CHECK ALL DIMENSIONS ON SITE PRIOR TOCOMMENCING CONSTRUCTION.
2. ARCHITECTURAL DRAWINGS ARE TO BE READ INCONJUNCTION WITH ALL RELEVANT CONSULTANTSDRAWINGS.
3. ALL BUILDING WORKS TO BE EXECUTED INACCORDANCE WITH AUSTRALIAN STANDARDS,BUILDING CODE OF AUSTRALIA & LOCAL & REGULATORYAUTHORITIES.
4. BUILDER TO NOTIFY ARCHITECT IMMEDIATELY OF ANYSERVICE LOCATION DISCREPANCIES OR CLASHES ONSITE.
STUD WALL - INTERNAL PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm PLASTERB'DLINING EACH SIDE & PAINT FINISH
STUD WALL - WET AREA PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm WATER RESISTANTPLASTERB'D LINING & PAINT FINISH, ORVILLA BOARD & TILES TO WET AREA SIDE.
200 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTSWITH PLASTERB'D LINING TO INTERNALSIDE (TO UNITS). WALLS TO ACHIEVE FRL120/60/30
STORE ROOMS - STUD WALL -STUD FRAMED WALLS TO 2100 HT WITHCHAINWIRE MESH & METAL FRAMINGABOVE
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
TYPE 7
TYPE 8
TYPE 9
TYPE 10
BALCONY PARTITIONS - STUD WALL -STEEL STUD FRAMED WALLS TO FULL HTWITH 1X CFC/BLUE BOARD LINING BOTHSIDES & ACRATEX FINISHTYPE 11
TYPE 12
LIFT/STAIR CORE - AFS WALL150 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISHTYPE 13
LIFT/STAIR CORE - AFS WALL262 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISH
S MWA ISSUE FOR CONSTRUCTION 22/06/16
T MWA UNIT NUMBERS AMENDED 12/07/16
U MWA TOILET ADDED TO U37 STORE 09/08/16
V MWA TOILET AMENDED & FW ADDED TO SOUTH END 30/08/16
W MWA CRITICAL STUD WALLS DIMENSIONED 23/11/16
X MWA AS BUILT 22/08/17
Y MWA AS BUILT CONDITIONS 03/10/17
Z1 MWA AS BUILT CONDITIONS 17/11/17
AutoCAD SHX Text283 - 285 VINCENT STREET
AutoCAD SHX TextAUG 2017
AutoCAD SHX Text1:100
AutoCAD SHX TextZ1
AutoCAD SHX TextA103
AutoCAD SHX Text16.04
AutoCAD SHX TextFIRST FLOOR PLAN
AutoCAD SHX TextLEEDERVILLE
AutoCAD SHX TextMIXED-USE DEVELOPMENT
-
G
1.1
ELEV
.A
2012
ELEV.A202
4
ELEV. 3A201
ELEV
.1
A20
1
A301A
A301A
C D F
2
3
H
A302C
A302C
A302B
A302B
A B
5
4
1
3.1
5
1
2
4
2.1
1.2
1.3
4.1
IEA.1
C.1 C.2G.1
G.2 G.3 I.1D.1
1.4
2.22.3
3.2 3.2
4100 550 1965 1960 3175 1400 6080 625 905 4570 1050 1025 3075 4475 2100 1960 940 617570
2562
2556
7570
25
100
1000
1000
1980
2450
4665
4260
3890
3045
3980
1325
775
595
410
775
100
95 95
22.350 F.LSHORT STAY 1LIVING
SHORT STAY 2LIVING
SHORT STAY 3LIVING
SHORT STAY 4LIVING
SHORT STAY 9LIVING
SHORT STAY 8LIVING /DINING
SHORT STAY 7LIVING /DINING
SHORT STAY 6LIVING /DINING
SHORT STAY 5LIVINGDINING
KITCHENTILES
DINING
KITCHENTILES
BED 2CARPET
BED 1CARPET
BATHTILES
ENS.TILES BED 1CARPET
BED 2CARPET
BATHTILES
ENS.TILES
FR. P PHWUL'DRYTILESL'DRYTILES
LIN.
TITLE
DININGCORRIDOR
STAIRS 1
KITCHENTILES
DININGKITCHEN
TILES
DINING KITCHENTILES
L'DRYTILES
BED 2CARPET
BED 1CARPET
BATHTILES
ENS.TILES BED 1
CARPET
BED 2CARPET
BATHTILES
ENS.TILES
DININGKITCHEN
TILES
KITCHENTILES
KITCHENTILES
KITCHENTILES
L'DRYTILES
ROBE
ROBE
ROBE
ROBE
HWUFR. FR.
LIN.
P P P P
FR.
P P
P P
ROBE
BATHTILESBED 1
CARPET
ROBE
LIN
EN L'DRYTILES
BATHTILES
ROBE L
INEN
L'DRYTILES
BATHTILES
BED 1CARPET
FR.
FR.
FR.
BATHTILES
ENS.TILES
ROBE
ROBE
L'DRYTILES
L'DRYTILES
ROBE RO
BE
ENS.TILES
BATHTILES
BED 2CARPET
BED 1CARPET
BED 2CARPET
BED 1CARPET
LIN.
LIN.
BALCONYTILES
BALCONYTILES
BALCONYTILES
BALCONYTILES
BALCONYTILES
BALCONYTILES
BALCONYTILES
CORRIDOR
C. UPDN
LIN.
HWU
HWU
HWU
HWU
HWU
AC
AC
AC
AC
ACAC
AC
AC
AC
E.
BALCONYTILES
BALCONYTILES
PLA
NTE
R TR
OUG
HS
WIC
KER
PLA
NTE
RS
LANDSCAPING
NOM. 600 HIGHBLOCKWORK PLANTERWALL. RENDER & PAINTFINISH
AWNINGBELOW
AWNINGBELOW
SECOND FLOOR PLAN
46130BOUNDARY
2824
5BO
UND
ARY
4190LANDSCAPING
2090BALCONY
CORE - REF A100
3000BALCONY
1490PASS.
5950CORRIDOR
7100CORRIDOR
4000SETBACK
3000BALCONY
4000SETBACK TO SLAB
1040L. WALL
4655COURTYARD
1210OPEN.
1295 4420OPENING
11790BUILDING
304011790BUILDING
4000SETBACK
2505BUILDING
2045BUILDING
2340L'SCAPE
2150
2045BUILDING
4000SETBACK TO SLAB
2040FEATURE WALL
11790BUILDING
11790BUILDING
1650L'SCAPE
4000SETBACK
3000BALCONY
1040
2517
00
60 1040L. WALL
1690OPEN.
20
2505BUILDING
4420OPENING
4195COURTYARD
2540FEATURE WALL
1210OPEN.
835
LIN.
HWU
ROBE
ROBE
ROBE
1810OPENING
1810OPENING
ELE.
& C
OM
MS
TO E
LEC
TRIC
AL
CO
NSU
LTA
NTS
REQ
UIRE
MEN
TS.
P P
FR.
P P
P P
4130
BUIL
DIN
G
2017
00BU
ILD
ING
4660
CL OF PARTY WALL
CL OF PARTY WALL
4675
CL OF PARTY WALL
4590
CL OF PARTY WALL
7100
3000 600 650 1050 700
1450
BED 1CARPET 31
50
3000 BATH
1450
3150
600 650 1050 700 3000 BATH
3000
3984
INTE
RNA
L B
ALC
ON
Y45
20 IN
TERN
AL
BA
LCO
NY
3990
INTE
RNA
L B
ALC
ON
Y
7170
390
390
1210
WIN
3419
INT
BA
LCO
NY
1070
640
4130
BUIL
DIN
G20
3424
INT
BA
LCO
NY
1250
3150
590 2310 3000 BATH
3065
2350 1500
1200
600 3035 INT BED WALL6002985 INT BED
3000
1900
3000
1750
1900
700
1785
5235 UNIT 9 KIT 1400 L'DRY 945
22501485
1200
6003235 INT BEDWALL 600 2885 INT BED
5235 UNIT 1 KIT1400 L'DRY
1205 19001900
700
1785
1700
900
OPE
N. 5
00
1700
900
OPE
N.5
0015
3087
017
0091
010
0046
510
0087
017
0018
0017
0080
010
0026
012
60
1000 1370
7000
7000
CL OF PARTY WALL
7100
7100
CL OF PARTY WALL
CL OF PARTY WALL
2025
6235
INTE
RNA
L B
ALC
ON
Y62
35 IN
TERN
AL
BA
LCO
NY
3510
INT
BA
LCO
NY
3510
INT
BALC
ON
Y39
8025
3980
20 2020
2020
1605
1355
555
190
3010
2080
0W
IN800WIN
930
1500
3640
2000
3560
INTE
RNA
L LI
VIN
G31
40 IN
TERN
AL
BED
136
10 IN
TERN
AL
LIV
ING
3060
INTE
RNA
L BE
D 1
3725
INTE
RNA
L LI
VIN
G29
00 IN
T LI
VIN
G
3000
1900
2000
3160
2095
800
1600
1300
3100
1600
1300
3100
3160
2095
2000
3640
1500
3730
ROBE
2020
3000
1500
1080
2020
3010
500
900
OPE
N.
500
900
OPE
N.
780
4130
BUIL
DIN
G
2110
BUIL
DIN
G80
0W
IN
20
2150
4655COURTYARD
4195COURTYARD
1000
1000
375
1000
475
1700
230
1570
2350
2350
2250 BATH1485 ENS
1200
7003135 INT BEDWALL 600 2885 INT BED
5355 UNIT 4 KIT1400 L'DRY
2350 BATH 1500 ENS
1200
700 2940 INT BED WALL6002985 INT BED
5235 UNIT 4 KIT 1400 L'DRY
DUCTDUCT
3815
945
2995 1
995
880
415
430
730
430
495
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G88
025
30 O
PEN
ING
250
320
800
WIN
3005
BUIL
DIN
G
1690OPEN
60
NOM. 600 HIGH190 BLOCKPLANTER WALL.
PRECAST PANEL TOEXTEND 1100mm TO
FORM BALUSTRADE TOCOURTYARDS. ACRATEX
FINISH
PRECAST PANEL TOEXTEND 1100mm TO
FORM BALUSTRADE TOCOURTYARDS. ACRATEX
FINISH
GL21
GL21
FR
FR
FR
FR FR
FR
FR
FR
FR
FR
BA402
D07
LIFT(RES)
LIFT(SHORT STAY)
GL17GL17
GL17GL17
GL17 GL17
GL17 GL17
1310
L2 SLAB
L2 SLAB
L2 SLAB
L2 SLAB
BRICK WALL
BRICK WALL
BRICK WALL
4500SETBACK TO FACADE WALL
500
WIC
KER
PLA
NTE
RS
PLA
NTE
R TR
OUG
HS
REFER TO LANDSCAPINGPLAN A701 FOR PLANT
SPECIES ALLOCATION TOPLANTERS
REFER TO LANDSCAPINGPLAN A701 FOR PLANT
SPECIES ALLOCATION TOPLANTERS
REFER TO LANDSCAPINGPLAN A701 FOR PLANT
SPECIES ALLOCATION TOPLANTERS
Project Name
Project Number
Scale
Title
Drawing Number
Date
Issue
DO NOT SCALE FROM THIS DRAWING.THIS DRAWING IS FOR READING PURPOSES ONLY.
Issue. Issue Description.By Date.
Q MWA 2ND LIFT + SHORT STAY AMENDMENTS 09/05/16
R MWA 2ND LIFT + SHORT STAY AMENDMENTS 16/05/16
FR = FIRE RATED DOOR _/60/30
STRUCTURAL ELEMENT - PRECAST CONC -PROVIDE LINING TO ELEMENTAPPROPRIATE TO LOCATION/SITUATION TOMATCH ADJACENT FINISHES TO ACHIEVEFRL 120/60/30
PARTY WALL - NON LOAD BEARING -X2 ROWS OF STEEL STUDS @ 600mm CTSMAX WITH 20mm ROW GAP WITHINSULATION & WALL LININGS TO ACHIEVE90/90/90 & Rw+Ctr >50. WALLSSEPARATING SHOPS 34 & 35 FROM ENTRYLOBBY TO ACHIEVE 120/120/120
STUD WALL - NON LOAD BEARING96mm HEAVY DUTY STEEL FRAMEWORK.AIRCELL INSULATION WITH 16mmFYRCHECK INTERNAL & 9mm CFC SHEETEXTERNAL LINING WITH VILLA SAND FINISH.WALLS TO ACHIEVE Rw+Ctr >50, & WHEREWITHIN 3m OF SIDE BOUNDARY OR ARE ASOLE OCCUPANCY UNIT WALL TO ACOMMON CORRIDOR, LOBBY ORSTAIRWELL; TO ACHIEVE FRL -/90/90
150 PRECAST CONC WALL -TO STRUCTURAL ENGINEERSREQUIREMENTS WITH BULK + FOIL SIDEDINSULATION & ANTI GLARE WITHPLASTERB'D LINING TO INTERNAL SIDE.WALLS TO ACHIEVE FRL 120/60/30 &Rw+Ctr >50.
250 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTS.WALLS TO ACHIEVE FRL 120/60/30
PACKING -PROVIDE PACKING & LINING TO WALL TOBE FLUSH WITH & TO MATCH ADJACENTWALLS FINISHES
NOTES:
1. BUILDER TO CHECK ALL DIMENSIONS ON SITE PRIOR TOCOMMENCING CONSTRUCTION.
2. ARCHITECTURAL DRAWINGS ARE TO BE READ INCONJUNCTION WITH ALL RELEVANT CONSULTANTSDRAWINGS.
3. ALL BUILDING WORKS TO BE EXECUTED INACCORDANCE WITH AUSTRALIAN STANDARDS,BUILDING CODE OF AUSTRALIA & LOCAL & REGULATORYAUTHORITIES.
4. BUILDER TO NOTIFY ARCHITECT IMMEDIATELY OF ANYSERVICE LOCATION DISCREPANCIES OR CLASHES ONSITE.
STUD WALL - INTERNAL PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm PLASTERB'DLINING EACH SIDE & PAINT FINISH
STUD WALL - WET AREA PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm WATER RESISTANTPLASTERB'D LINING & PAINT FINISH, ORVILLA BOARD & TILES TO WET AREA SIDE.
200 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTSWITH PLASTERB'D LINING TO INTERNALSIDE (TO UNITS). WALLS TO ACHIEVE FRL120/60/30
STORE ROOMS - STUD WALL -STUD FRAMED WALLS TO 2100 HT WITHCHAINWIRE MESH & METAL FRAMINGABOVE
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
TYPE 7
TYPE 8
TYPE 9
TYPE 10
BALCONY PARTITIONS - STUD WALL -STEEL STUD FRAMED WALLS TO FULL HTWITH 1X CFC/BLUE BOARD LINING BOTHSIDES & ACRATEX FINISHTYPE 11
TYPE 12
LIFT/STAIR CORE - AFS WALL150 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISHTYPE 13
LIFT/STAIR CORE - AFS WALL262 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISH
S MWA ISSUE FOR CONSTRUCTION 24/06/16
T MWA NORTH FEATURE WALL SET BACK 21/07/16
U MWA SHORT STAY UNIT 8 UA BATHROOM ADDED 26/07/16
V MWA AS BUILT 22/08/17
W MWA AS BUILT CONDITIONS 03/10/17
Z1 MWA AS BUILT CONDITIONS 17/11/17
AutoCAD SHX Text283 - 285 VINCENT STREET
AutoCAD SHX TextAUG 2017
AutoCAD SHX Text1:100
AutoCAD SHX TextZ1
AutoCAD SHX TextA104
AutoCAD SHX Text16.04
AutoCAD SHX TextSECOND FLOOR PLAN
AutoCAD SHX TextLEEDERVILLE
AutoCAD SHX TextMIXED-USE DEVELOPMENT
-
G
1.1
ELEV
.A
2012
ELEV.A202
4
ELEV. 3A201
ELEV
.1
A20
1
A301A
A301A
C D F
2
3
H
A302C
A302C
A302B
A302B
A B
5
4
1
3.1
5
1
2
4
2.1
1.2
1.3
4.1
IEA.1
C.1 C.2G.1
G.2 G.3 I.1D.1
1.4
2.22.3
3.2 3.2
4100 550 1965 1960 3175 1400 6080 625 905 4570 1050 1025 3075 4475 2100 1960 940 617570
2562
2556
7570
25
100
1000
1000
1980
2450
4665
4260
3890
3045
3980
1325
775
595
410
775
100
95 95
VOID
VOID
25.350 F.LSHORT STAY 10LIVING
SHORT STAY 11LIVING
SHORT STAY 12LIVING
SHORT STAY 13LIVING
SHORT STAY 18LIVING
SHORT STAY 17LIVING /DINING
SHORT STAY 16LIVING /DINING
SHORT STAY 15LIVING /DINING
SHORT STAY 14LIVING
KITCHEN TILES
BED 1CARPET
BATHTILES
BED 1CARPET
FR.P P
L'DRYTILES
LIN.
TITLE
BALCONYTILES
BALCONYTILES
BATHTILES
KITCHENTILES
HWU L'DRYTILES
W.I.R
W.I.R
FR. P P
DININGDINING
AWNINGBELOW
FEATURE FACEBRICK WORK
SCREEN BELOW.
ROOF BELOW ROOF BELOW
THIRD FLOOR PLAN
DINING CORRIDOR
STAIRS 1
KITCHENTILES
DININGKITCHEN
TILES
DININGKITCHEN
TILES
L'DRYTILES
BED 2CARPET
BED 1CARPET
BATHTILES
ENS.TILES BED 1
CARPET
BED 2CARPET
BATHTILES
ENS.TILES
DINING
KITCHENTILES
KITCHENTILES
KITCHENTILES
KITCHENTILES
L'DRYTILES
ROBE
ROBE
ROBE
ROBE
HWU FR. FR.
LIN.
P P P P
FR.
P P
P P
P P
FR.
P P
ROBE
BATHTILES
BED 1CARPET
ROBE
LIN
EN L'DRYTILES
BATHTILES
BED 1CARPET
ROBE
LIN
EN L'DRYTILES
BATHTILESBED 1CARPET
FR.
FR.
FR.
BATHTILES
ENS.TILES
ROBE
ROBE
L'DRYTILES
L'DRYTILES
ROBE RO
BE
ENS.TILES
BATHTILES
BED 2CARPET
BED 1CARPET
BED 2CARPET
BED 1CARPET
LIN.
LIN.
BALCONYTILES
BALCONYTILES
BALCONYTILES
BALCONYTILES
BALCONYTILES
BALCONYTILES
BALCONYTILES
CORRIDOR
C.UP
DN
LIN.
HWU
HWU
HWU
HWU
HWU
AC
AC
AC
AC
ACAC
AC
AC
AC
E.
LIN.
GLAZEDBALUSTRADE.
GLAZEDBALUSTRADE.
VERTICALBATTEN SCREEN.
AWNINGBELOW
GLAZEDBALUSTRADE.
46130BOUNDARY
2824
5BO
UND
ARY
CORE - REF A100
3000BALCONY
1550PASS.
5950CORRIDOR
6970CORRIDOR
1700L'SCAPE
4000SETBACK
3000BALCONY
5500SETBACK
1210OPEN.
1295 4420OPENING
11790BUILDING
11790BUILDING
2505BUILDING
2045BUILDING
2045BUILDING
8500 9830BUILDING
9830BUILDING
9000SETBACK
3000BALCONY
1040L. WALL
990 970OPEN.
20
2505BUILDING
4420OPENING
1210OPEN.
835
1810OPENING
1810OPENING
4130
BUIL
DIN
G
2021
10BU
ILD
ING
4660
4675
4590
7100
3000 600 650 1050 700
1450
3150
3000 BATH
1450
3150
600 650 1050 700 3000 BATH
3000
3984
INTE
RNA
L B
ALC
ON
Y45
20 IN
TERN
AL
BA
LCO
NY
3990
INTE
RNA
L B
ALC
ON
Y
6173
800
WIN
3419
INT
BA
LCO
NY
3424
INT
BA
LCO
NY
1250
3150
590 2310 3000 BATH
3065
2350 1500
1200
600 3035 INT BED WALL6002985 INT BED
3000
1900
3000
1750
1900
700
1785
5235 UNIT 18 KIT 1400 L'DRY 945
22501485
1200
6003235 INT BEDWALL 600 2885 INT BED
5235 UNIT 10 KIT1400 L'DRY
1205 19001900
700
1785
1700
1700
800
WIN
600
1230
870
1700
910
1000
465
1000
870
1700
1800
1700
800
1000
260
1260
1000
7000
7000
7100
6100
2025
6235
INTE
RNA
L B
ALC
ON
Y62
35 IN
TERN
AL
BA
LCO
NY
3510
INT
BA
LCO
NY
3510
INT
BALC
ON
Y39
8025
3980
20 2020
20
1500
3640
2000
3560
INTE
RNA
L LI
VIN
G31
40 IN
TERN
AL
BED
136
10 IN
TERN
AL
LIV
ING
3060
INTE
RNA
L BE
D 1
3725
INTE
RNA
L LI
VIN
G29
00 IN
T LI
VIN
G
3000
1900
2000
3160
2095
800
1600
1300
3100
1600
1300
3100
3160
2095
2000
3640
1500
2100
4130
BUIL
DIN
G
2110
BUIL
DIN
G80
0W
IN
204655
COURTYARD4195
COURTYARD
1000
1000
375
1000
475
1700
230
1700
2350
2350
1450 BATH 4820 KITCHEN3080 INT BED
DUCT
CL OF PARTY WALL
CL OF PARTY WALL
CL OF PARTY WALL
CL OF PARTY WALL
CL OF PARTY WALL
CL OF PARTY WALL
CL OF PARTY WALL
2100
3000BALCONY
2600
1280
3885
285
1000
1000
2090BALCONY
2090BALCONY
910
910
2600
1370
800WIN
800WIN3
885
985
2830
INT
KIT
6540SETBACK
7040SETBACK
3000
1465 BATH4690 KITCHEN 3067 INT BED
DUCT
880
415
430
730
430
495
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G88
025
30 O
PEN
ING
250
320
800
WIN
2005
BUIL
DIN
G
390
390
1070
640
1605
1355
555
190
2010
BUI
LDIN
G80
0W
IN25
30 O
PEN
ING
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G25
30 O
PEN
ING
800
WIN
600
GL21
GL21
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
STUD WALL TOBALUSTRADE HT.CFC/BLUE BOARDLINING & ACRATEXFINISH
STUD WALL TOBALUSTRADE HT.CFC/BLUE BOARDLINING & ACRATEXFINISH
AA404
D07
LIFT(RES)
LIFT(SHORT STAY)
720
72013
10
Project Name
Project Number
Scale
Title
Drawing Number
Date
Issue
DO NOT SCALE FROM THIS DRAWING.THIS DRAWING IS FOR READING PURPOSES ONLY.
Issue. Issue Description.By Date.
P MWA ISSUE FOR BUILDING PERMIT 11/04/16
Q MWA 2ND LIFT + SHORT STAY AMENDMENTS 09/05/16
R MWA 2ND LIFT + SHORT STAY AMENDMENTS 16/05/16
FR = FIRE RATED DOOR _/60/30
STRUCTURAL ELEMENT - PRECAST CONC -PROVIDE LINING TO ELEMENTAPPROPRIATE TO LOCATION/SITUATION TOMATCH ADJACENT FINISHES TO ACHIEVEFRL 120/60/30
PARTY WALL - NON LOAD BEARING -X2 ROWS OF STEEL STUDS @ 600mm CTSMAX WITH 20mm ROW GAP WITHINSULATION & WALL LININGS TO ACHIEVE90/90/90 & Rw+Ctr >50. WALLSSEPARATING SHOPS 34 & 35 FROM ENTRYLOBBY TO ACHIEVE 120/120/120
STUD WALL - NON LOAD BEARING96mm HEAVY DUTY STEEL FRAMEWORK.AIRCELL INSULATION WITH 16mmFYRCHECK INTERNAL & 9mm CFC SHEETEXTERNAL LINING WITH VILLA SAND FINISH.WALLS TO ACHIEVE Rw+Ctr >50, & WHEREWITHIN 3m OF SIDE BOUNDARY OR ARE ASOLE OCCUPANCY UNIT WALL TO ACOMMON CORRIDOR, LOBBY ORSTAIRWELL; TO ACHIEVE FRL -/90/90
150 PRECAST CONC WALL -TO STRUCTURAL ENGINEERSREQUIREMENTS WITH BULK + FOIL SIDEDINSULATION & ANTI GLARE WITHPLASTERB'D LINING TO INTERNAL SIDE.WALLS TO ACHIEVE FRL 120/60/30 &Rw+Ctr >50.
250 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTS.WALLS TO ACHIEVE FRL 120/60/30
PACKING -PROVIDE PACKING & LINING TO WALL TOBE FLUSH WITH & TO MATCH ADJACENTWALLS FINISHES
NOTES:
1. BUILDER TO CHECK ALL DIMENSIONS ON SITE PRIOR TOCOMMENCING CONSTRUCTION.
2. ARCHITECTURAL DRAWINGS ARE TO BE READ INCONJUNCTION WITH ALL RELEVANT CONSULTANTSDRAWINGS.
3. ALL BUILDING WORKS TO BE EXECUTED INACCORDANCE WITH AUSTRALIAN STANDARDS,BUILDING CODE OF AUSTRALIA & LOCAL & REGULATORYAUTHORITIES.
4. BUILDER TO NOTIFY ARCHITECT IMMEDIATELY OF ANYSERVICE LOCATION DISCREPANCIES OR CLASHES ONSITE.
STUD WALL - INTERNAL PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm PLASTERB'DLINING EACH SIDE & PAINT FINISH
STUD WALL - WET AREA PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm WATER RESISTANTPLASTERB'D LINING & PAINT FINISH, ORVILLA BOARD & TILES TO WET AREA SIDE.
200 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTSWITH PLASTERB'D LINING TO INTERNALSIDE (TO UNITS). WALLS TO ACHIEVE FRL120/60/30
STORE ROOMS - STUD WALL -STUD FRAMED WALLS TO 2100 HT WITHCHAINWIRE MESH & METAL FRAMINGABOVE
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
TYPE 7
TYPE 8
TYPE 9
TYPE 10
BALCONY PARTITIONS - STUD WALL -STEEL STUD FRAMED WALLS TO FULL HTWITH 1X CFC/BLUE BOARD LINING BOTHSIDES & ACRATEX FINISHTYPE 11
TYPE 12
LIFT/STAIR CORE - AFS WALL150 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISHTYPE 13
LIFT/STAIR CORE - AFS WALL262 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISH
S MWA ISSUE FOR CONSTRUCTION 24/06/16
T MWA SHORT STAY UNIT 17 UA BATHROOM ADDED 26/07/16
U MWA AS BUILT 22/08/17
Z MWA AS BUILT CONDITIONS 24/10/17
Z1 MWA AS BUILT CONDITIONS 17/11/17
AutoCAD SHX Text283 - 285 VINCENT STREET
AutoCAD SHX TextAUG 2017
AutoCAD SHX Text1:100
AutoCAD SHX TextZ1
AutoCAD SHX TextA105
AutoCAD SHX Text16.04
AutoCAD SHX TextTHIRD FLOOR PLAN
AutoCAD SHX TextLEEDERVILLE
AutoCAD SHX TextMIXED-USE DEVELOPMENT
-
G
1.1
ELEV
.A
2012
ELEV.A202
4
ELEV. 3A201
ELEV
.1
A20
1
A301A
A301A
C D F
2
3
H
A302C
A302C
A302B
A302B
A B
5
4
1
3.1
5
1
2
4
2.1
1.2
1.3
4.1
IEA.1
C.1 C.2G.1
G.2 G.3 I.1D.1
1.4
2.22.3
3.2 3.2
4100 550 1965 1960 3175 1400 6080 625 905 4570 1050 1025 3075 4475 2100 1960 940 617570
2562
2556
7570
25
100
1000
1000
1980
2450
4665
4260
3890
3045
3980
1325
775
595
410
775
100
95 95
28.350 F.LUNIT 19LIVING
UNIT 20LIVING
UNIT 21LIVING
UNIT 22LIVING /DINING
UNIT 27LIVING
UNIT 26LIVING /DINING
TILES
UNIT 25LIVING /DINING
CARPET
UNIT 24LIVING /DINING
UNIT 23LIVING /DINING
KITCHENTILES
BED 1CARPETBATH
TILESBED 1CARPET
FR. P P
L'DRYTILES
LIN.
TITLE
BALCONYTILES
BALCONYTILES
BATHTILES
KITCHENTILES
LIN. L'DRYTILES
W.I.R W.I.R
FR.P P
ROOF BELOW ROOF BELOW
ROOF BELOW ROOF BELOW
FOURTH FLOOR PLAN
DINING
CORRIDOR
STAIRS 1
KITCHENTILES
DINING KITCHENTILES
DININGKITCHEN
TILES
L'DRYTILES
BED 2CARPET
BED 1CARPET BATH
TILES
ENS.TILES BED 1
CARPET
BED 2CARPET
BATHTILES
ENS.TILES
DINING
KITCHENTILES
KITCHENTILES
KITCHENVINYL
KITCHENTILES
L'DRYTILES
ROBE
ROBE
ROBE
ROBE
HWU FR. FR.
LIN.
P P P P
FR.
P P
P P
FR.
P P
ROBE
BATHTILESBED 1
CARPET
ROBE
L'DRYTILES
BATHTILES
BED 1CARPET
ROBE
LIN
EN
L'DRYTILES
BATHTILES
BED 1CARPET
FR.
FR.
FR.
BATHTILES
ENS.TILES
ROBE
ROBE
L'DRYTILES
L'DRYTILES
ROBE RO
BE
ENS.TILES
BATHTILES
BED 2CARPET
BED 1CARPET
BED 2CARPET
BED 1CARPET
LIN.
LIN.
BALCONYTILES
BALCONYTILES
BALCONYTILES
BALCONYTILES
BALCONYTILES
CORRIDOR
C.
UPDN
LIN.
HWU
HWU
HWU
HWU
HWU
AC
AC
AC
AC
ACAC
AC
AC
AC
E.
VOID
VOID
HWUHWU
GLAZEDBALUSTRADE.
AWNINGBELOW
GLAZEDBALUSTRADE.
AWNINGBELOW
GLAZEDBALUSTRADE.
46130BOUNDARY
2824
5BO
UND
ARY
CORE - REF A100
3000BALCONY
1490PASS.
5950CORRIDOR
6970CORRIDOR
1700L'SCAPE
4000SETBACK
3000BALCONY
5500SETBACK
1210OPEN.
1295 4420OPENING
11790BUILDING
11790BUILDING
2505BUILDING
2045BUILDING
2045BUILDING
8500 9830BUILDING
9830BUILDING
9000SETBACK
3000BALCONY
1040L. WALL
990 970OPEN.
20
2505BUILDING
4420OPENING
1210OPEN.
835
1810OPENING
1810OPENING
4130
BUIL
DIN
G
2021
10BU
ILD
ING
4660
4675
4590
7100
3000 600
650
820
140045
2414
50
3150
600 650 1050 700 3000 BATH
3000
3984
INTE
RNA
L B
ALC
ON
Y45
20 IN
TERN
AL
BA
LCO
NY
3990
INTE
RNA
L B
ALC
ON
Y
5173
800
WIN
3419
INT
BA
LCO
NY
3424
INT
BA
LCO
NY
1450
3250
1550
2885
2350 1500
1200
600 3035 INT BED WALL6002985 INT BED
3000
1900
3000
1750
1900
700
1785
5235 UNIT 27 KIT 1400 L'DRY 945
22501485
1200
6003235 INT BEDWALL 600 2885 INT BED
5235 UNIT 19 KIT1400 L'DRY
1205 19001900
700
1785
1700
1700
1230
970
1500
1120
1000
350
1000
1070
1500
1800
1500
1000
1000
260
1260
1000
7000
7000
7100
5100
2025
6235
INTE
RNA
L B
ALC
ON
Y62
35 IN
TERN
AL
BA
LCO
NY
3510
INT
BA
LCO
NY
3510
INT
BALC
ON
Y39
8025
3980
20 2020
20
1500
3640
2000
3560
INTE
RNA
L LI
VIN
G31
40 IN
TERN
AL
BED
136
10 IN
TERN
AL
LIV
ING
3060
INTE
RNA
L BE
D 1
3725
INTE
RNA
L LI
VIN
G29
00 IN
T LI
VIN
G
3000
1900
2000
3160
2095
800
1600
1300
3100
1600
1300
3100
3160
2095
2000
3640
1500
1100
4130
BUIL
DIN
G
2110
BUIL
DIN
G80
0W
IN
20
1000
1000
375
1000
475
1700
230
1700
2350
2350
1450 BATH 4820 KITCHEN3080 INT BED
DUCT
1100
3000BALCONY
2600
1230
2930
2000
2000
2090BALCONY
2090BALCONY
910
910
2600
1370
800WIN
800WIN
2930
985
1830
INT
KIT
6540SETBACK
7040SETBACK
3000
PANTRY
CL OF PARTY WALL
CL OF PARTY WALL
CL OF PARTY WALL
CL OF PARTY WALL
CL OF PARTY WALL
CL OF PARTY WALL
CL OF PARTY WALL
1498 BATH4820 KITCHEN 3080 INT BED
DUCT
390
390
1070
640
1605
1355
555
190
880
415
430
730
430
495
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G88
025
30 O
PEN
ING
570
800
WIN
3010
25
570
800
WIN
800
WIN
600
800
WIN
600
GL21
GL21
BALCONYTILES
BALCONYTILES
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FEATURE FACEBRICK WORK
SCREEN BELOW.
VERTICALBATTEN SCREEN.
GLAZEDBALUSTRADE.
AA404
D07
LIFT(RES)
LIFT(SHORT STAY)
HWU
L'DRYTILES
1270
D17FR
100 1000 1001200
ROBE
2570 6200
P
100
300
1700
INT
L'DRY
CRI
TICA
L
1700
INT
L'DRY
CRI
TICA
L
720
72013
10
Project Name
Project Number
Scale
Title
Drawing Number
Date
Issue
DO NOT SCALE FROM THIS DRAWING.THIS DRAWING IS FOR READING PURPOSES ONLY.
Issue. Issue Description.By Date.
O MWA ISSUE FOR BUILDING PERMIT 24/03/16
P MWA ISSUE FOR BUILDING PERMIT 11/04/16
Q MWA 2ND LIFT + SHORT STAY AMENDMENTS 09/05/16
R MWA 2ND LIFT + SHORT STAY AMENDMENTS 16/05/16
FR = FIRE RATED DOOR _/60/30
STRUCTURAL ELEMENT - PRECAST CONC -PROVIDE LINING TO ELEMENTAPPROPRIATE TO LOCATION/SITUATION TOMATCH ADJACENT FINISHES TO ACHIEVEFRL 120/60/30
PARTY WALL - NON LOAD BEARING -X2 ROWS OF STEEL STUDS @ 600mm CTSMAX WITH 20mm ROW GAP WITHINSULATION & WALL LININGS TO ACHIEVE90/90/90 & Rw+Ctr >50. WALLSSEPARATING SHOPS 34 & 35 FROM ENTRYLOBBY TO ACHIEVE 120/120/120
STUD WALL - NON LOAD BEARING96mm HEAVY DUTY STEEL FRAMEWORK.AIRCELL INSULATION WITH 16mmFYRCHECK INTERNAL & 9mm CFC SHEETEXTERNAL LINING WITH VILLA SAND FINISH.WALLS TO ACHIEVE Rw+Ctr >50, & WHEREWITHIN 3m OF SIDE BOUNDARY OR ARE ASOLE OCCUPANCY UNIT WALL TO ACOMMON CORRIDOR, LOBBY ORSTAIRWELL; TO ACHIEVE FRL -/90/90
150 PRECAST CONC WALL -TO STRUCTURAL ENGINEERSREQUIREMENTS WITH BULK + FOIL SIDEDINSULATION & ANTI GLARE WITHPLASTERB'D LINING TO INTERNAL SIDE.WALLS TO ACHIEVE FRL 120/60/30 &Rw+Ctr >50.
250 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTS.WALLS TO ACHIEVE FRL 120/60/30
PACKING -PROVIDE PACKING & LINING TO WALL TOBE FLUSH WITH & TO MATCH ADJACENTWALLS FINISHES
NOTES:
1. BUILDER TO CHECK ALL DIMENSIONS ON SITE PRIOR TOCOMMENCING CONSTRUCTION.
2. ARCHITECTURAL DRAWINGS ARE TO BE READ INCONJUNCTION WITH ALL RELEVANT CONSULTANTSDRAWINGS.
3. ALL BUILDING WORKS TO BE EXECUTED INACCORDANCE WITH AUSTRALIAN STANDARDS,BUILDING CODE OF AUSTRALIA & LOCAL & REGULATORYAUTHORITIES.
4. BUILDER TO NOTIFY ARCHITECT IMMEDIATELY OF ANYSERVICE LOCATION DISCREPANCIES OR CLASHES ONSITE.
STUD WALL - INTERNAL PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm PLASTERB'DLINING EACH SIDE & PAINT FINISH
STUD WALL - WET AREA PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm WATER RESISTANTPLASTERB'D LINING & PAINT FINISH, ORVILLA BOARD & TILES TO WET AREA SIDE.
200 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTSWITH PLASTERB'D LINING TO INTERNALSIDE (TO UNITS). WALLS TO ACHIEVE FRL120/60/30
STORE ROOMS - STUD WALL -STUD FRAMED WALLS TO 2100 HT WITHCHAINWIRE MESH & METAL FRAMINGABOVE
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
TYPE 7
TYPE 8
TYPE 9
TYPE 10
BALCONY PARTITIONS - STUD WALL -STEEL STUD FRAMED WALLS TO FULL HTWITH 1X CFC/BLUE BOARD LINING BOTHSIDES & ACRATEX FINISHTYPE 11
TYPE 12
LIFT/STAIR CORE - AFS WALL150 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISHTYPE 13
LIFT/STAIR CORE - AFS WALL262 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISH
S MWA ISSUE FOR CONSTRUCTION 24/06/16
T MWA AS BUILT 22/08/17
Z MWA AS BUILT CONDITIONS 24/10/17
Z1 MWA AS BUILT CONDITIONS 17/11/17
AutoCAD SHX Text283 - 285 VINCENT STREET
AutoCAD SHX TextAUG 2017
AutoCAD SHX Text1:100
AutoCAD SHX TextZ1
AutoCAD SHX TextA106
AutoCAD SHX Text16.04
AutoCAD SHX TextFOURTH FLOOR PLAN
AutoCAD SHX TextLEEDERVILLE
AutoCAD SHX TextMIXED-USE DEVELOPMENT
-
G
1.1
ELEV
.A
2012
ELEV.A202
4
ELEV. 3A201
ELEV
.1
A20
1
A301A
A301A
C D F
2
3
H
A302C
A302C
A302B
A302B
A B
5
4
1
3.1
5
1
2
4
2.1
1.2
1.3
4.1
IEA.1
C.1 C.2G.1
G.2 G.3 I.1D.1
1.4
2.22.3
3.2 3.2
4100 550 1965 1960 3175 1400 6080 625 905 4570 1050 1025 3075 4475 2100 1960 940 617570
2562
2556
7570
25
100
1000
1000
1980
2450
4665
4260
3890
3045
3980
1325
775
595
410
775
100
95 95
31.350 F.L
UNIT 28LIVING /DINING
UNIT 29LIVING /DINING
UNIT 33LIVING
UNIT 32LIVING /DINING
UNIT 30LIVING /DINING
BATHTILES
L'DRYTILES
ROBE & LINEN
TITLE
BALCONYTILES
BALCONYTILES
ENS.TILES
KITCHENTILES
ROBE
L'DRYTILES
ROBE
FR.
BED 2CARPET
BED 1CARPET
BATHTILES
BED 2CARPET
BED 3CARPET
ROBE
ROBE
BALCONYTILES
ENS.TILES
ROBE & LINEN ENS.TILES
L'DRYTILES
STUDY
BED 1CARPET
BED 1CARPET
KITTILES
FR.
P P
FR.
BED 2CARPET
BED 3CARPET
ROBE
ROBEBATH
TILES
ROOF BELOW
LAN
DSC
API
NG
BEL
OW
LAN
DSC
API
NG
BEL
OW
ROOF BELOW
ROOF BELOW ROOF BELOW
BALC
ON
Y BE
LOW
BALC
ON
Y BE
LOW
ROOF BELOW ROOF BELOW
FIFTH FLOOR PLAN
CORRIDOR
STAIRS 1
KITCHENTILES
BED 1CARPET
BED 2CARPET
BATHTILES
ENS.TILES
KITCHENTILES
KITCHENTILES
L'DRYTILES
ROBE
ROBE
FR.
LIN.
P P
P P
P P
ROBE
L'DRYTILES
BATHTILESBED 1
CARPET
ENSTILES
BED 1CARPET
BED 3CARPET
FR.
BALCONYTILES
BALCONYTILES
C.UP DN
HWU
HWU
AC
AC
AC
E.
VOID
HWU
HWU
GLAZEDBALUSTRADE.
GLAZEDBALUSTRADE.
BALUSTRADEBELOW.
CL OF PARTY WALL
CL
CL OF PARTY WALL
CL OF PARTY WALL
46130BOUNDARY
2824
5BO
UND
ARY
CORE - REF A100
1490PASS.
5950CORRIDOR
6970CORRIDOR
1700L'SCAPE
4000SETBACK
3000BALCONY
5950OPENING
11790BUILDING
10805BUILDING
2045BUILDING
8500 10805BUILDING
10825BUILDING
9000SETBACK
2500BALCONY BED
7000OPENING
1210OPEN.
835
1810OPENING
4130
BUIL
DIN
G
2017
00BU
ILD
ING
4660
4675
7780
7100
1450
3150
1825
3170 7
610
INTE
RNA
L B
ALC
ON
Y45
20 IN
TERN
AL
BA
LCO
NY
3990
INTE
RNA
L B
ALC
ON
Y12
10W
IN34
19 IN
T B
ALC
ON
Y
1450
3248
820 1550 BATH
2885
2350 1500
1200
600 3035 INT BED WALL6003000 INT BED
3000
1900
3000
1750
1900
700
1785
5286 UNIT 33 KIT 1400 L'DRY 945
1960
1700
800
WIN
600
1230
870
1700
965
1000
2276
1700
1800
1700
847
1000
215
1410
014
100
2025
9895
INTE
RNA
L B
ALC
ON
Y98
80 IN
T B
ALC
ON
Y39
80 S
ETBA
CK
2520 2020
20
3560
INTE
RNA
L LI
VIN
G31
80 IN
TERN
AL
BED
136
40 IN
TERN
AL
LIV
ING
3100
INTE
RNA
L BE
D 1
2960
BED
2 &
329
65 IN
T BE
D 2
& 3
3980
SETB
AC
K
20
1000
3000 BATH 3100 BED 13100 INT BED 3
3000BALCONY
3980
1830
INT
KIT
8500SETBACK
7040SETBACK
3980
SETB
AC
K
600600
6400 KITCHEN
2200
3180
5250 HALLWAY
2615 BATH2780 BED 2 2780 INT BED 3600 600
600
600
600
1800
810 1230 570
1800
610
900
2730
3080
EN
S30
95 E
NS
1500
1500
610
980
1750 9002730
2615 BATH2780 BED 2 2780 INT BED 3600 600
1260
1700
1700
12403690
2000
1000
1340
925
1860
3350
895
1120
415
430
2530
OPE
NIN
G25
30 O
PEN
ING
2530
OPE
NIN
G25
30 O
PEN
ING
1810
OPE
NIN
G
1810
OPE
NIN
G
2530
OPE
NIN
G
2530
OPE
NIN
G88
025
30 O
PEN
ING
730
415 5
1025
30 O
PEN
ING
290
590
1810
OPE
N97
015
0
GL24
GL24
FR
FR
FR
FR
FR
FRD07
LIFT(RES)
LIFT(SHORT STAY)
6200
3100BALCONY LIVING
1700
INT
L'DRY
CRI
TICA
L
1310
450
3000 ENS
1050
KITCHENTILES
UNIT 31LIVING /DINING
5400
BALCONYTILES
OF PARTY WALL
Project Name
Project Number
Scale
Title
Drawing Number
Date
Issue
DO NOT SCALE FROM THIS DRAWING.THIS DRAWING IS FOR READING PURPOSES ONLY.
Issue. Issue Description.By Date.
P MWA ISSUE FOR BUILDING PERMIT 11/04/16
Q MWA 2ND LIFT + SHORT STAY AMENDMENTS 09/05/16
R MWA 2ND LIFT + SHORT STAY AMENDMENTS 16/05/16
FR = FIRE RATED DOOR _/60/30
STRUCTURAL ELEMENT - PRECAST CONC -PROVIDE LINING TO ELEMENTAPPROPRIATE TO LOCATION/SITUATION TOMATCH ADJACENT FINISHES TO ACHIEVEFRL 120/60/30
PARTY WALL - NON LOAD BEARING -X2 ROWS OF STEEL STUDS @ 600mm CTSMAX WITH 20mm ROW GAP WITHINSULATION & WALL LININGS TO ACHIEVE90/90/90 & Rw+Ctr >50. WALLSSEPARATING SHOPS 34 & 35 FROM ENTRYLOBBY TO ACHIEVE 120/120/120
STUD WALL - NON LOAD BEARING96mm HEAVY DUTY STEEL FRAMEWORK.AIRCELL INSULATION WITH 16mmFYRCHECK INTERNAL & 9mm CFC SHEETEXTERNAL LINING WITH VILLA SAND FINISH.WALLS TO ACHIEVE Rw+Ctr >50, & WHEREWITHIN 3m OF SIDE BOUNDARY OR ARE ASOLE OCCUPANCY UNIT WALL TO ACOMMON CORRIDOR, LOBBY ORSTAIRWELL; TO ACHIEVE FRL -/90/90
150 PRECAST CONC WALL -TO STRUCTURAL ENGINEERSREQUIREMENTS WITH BULK + FOIL SIDEDINSULATION & ANTI GLARE WITHPLASTERB'D LINING TO INTERNAL SIDE.WALLS TO ACHIEVE FRL 120/60/30 &Rw+Ctr >50.
250 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTS.WALLS TO ACHIEVE FRL 120/60/30
PACKING -PROVIDE PACKING & LINING TO WALL TOBE FLUSH WITH & TO MATCH ADJACENTWALLS FINISHES
NOTES:
1. BUILDER TO CHECK ALL DIMENSIONS ON SITE PRIOR TOCOMMENCING CONSTRUCTION.
2. ARCHITECTURAL DRAWINGS ARE TO BE READ INCONJUNCTION WITH ALL RELEVANT CONSULTANTSDRAWINGS.
3. ALL BUILDING WORKS TO BE EXECUTED INACCORDANCE WITH AUSTRALIAN STANDARDS,BUILDING CODE OF AUSTRALIA & LOCAL & REGULATORYAUTHORITIES.
4. BUILDER TO NOTIFY ARCHITECT IMMEDIATELY OF ANYSERVICE LOCATION DISCREPANCIES OR CLASHES ONSITE.
STUD WALL - INTERNAL PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm PLASTERB'DLINING EACH SIDE & PAINT FINISH
STUD WALL - WET AREA PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm WATER RESISTANTPLASTERB'D LINING & PAINT FINISH, ORVILLA BOARD & TILES TO WET AREA SIDE.
200 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTSWITH PLASTERB'D LINING TO INTERNALSIDE (TO UNITS). WALLS TO ACHIEVE FRL120/60/30
STORE ROOMS - STUD WALL -STUD FRAMED WALLS TO 2100 HT WITHCHAINWIRE MESH & METAL FRAMINGABOVE
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
TYPE 7
TYPE 8
TYPE 9
TYPE 10
BALCONY PARTITIONS - STUD WALL -STEEL STUD FRAMED WALLS TO FULL HTWITH 1X CFC/BLUE BOARD LINING BOTHSIDES & ACRATEX FINISHTYPE 11
TYPE 12
LIFT/STAIR CORE - AFS WALL150 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISHTYPE 13
LIFT/STAIR CORE - AFS WALL262 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISH
S MWA ISSUE FOR CONSTRUCTION 24/06/16
T MWA SEPARATE UNITS 31 & 32 REINSTATED 12/07/16
U MWA AS BUILT 22/08/17
V MWA AS BUILT CONDITIONS 03/10/17
Z1 MWA AS BUILT CONDITIONS 17/11/17
AutoCAD SHX Text283 - 285 VINCENT STREET
AutoCAD SHX TextAUG 2017
AutoCAD SHX Text1:100
AutoCAD SHX TextZ1
AutoCAD SHX TextA107
AutoCAD SHX Text16.04
AutoCAD SHX TextFIFTH FLOOR PLAN
AutoCAD SHX TextLEEDERVILLE
AutoCAD SHX TextMIXED-USE DEVELOPMENT
-
STAIRS 1
LIFT
DN
ROOF TOP DECKTILES
AWNINGBELOW
ROOF BELOW
LAN
DSC
API
NG
BEL
OW
LAN
DSC
API
NG
BEL
OW
ROOF BELOW
ROOF BELOW ROOF BELOW
BALC
ON
Y BE
LOW
BALC
ON
Y BE
LOW
ROOF BELOW
ALL CONCRETE ROOFS TO HAVE AWATERPROOF WITH FALLS TO DRAINAGE.REFER TO HYDRAULIC DRAWINGS.
ROOF BELOW
AW
NIN
G B
ELO
W
AW
NIN
G B
ELO
W
SIXTH FLOOR PLAN
34.350 F.L
34.450 F.L
ARTIFICIALLAWN
ALL LANDSCAPEDAREAS TO HAVE AWATERPROOFMEMBRANE TO SUIT.
ROOF BELOW
ALL CONCRETE ROOFS TO HAVE A WATERPROOFMEMBRANE TO SUIT WITH FALLS TO DRAINAGE.REFER TO HYDRAULIC DRAWINGS.
TOP OF FACE BRICK WORKFACADE TO FUTURE DETAIL.
TOP OF VERTICAL BATTENFACADE TO FUTURE DETAIL.
TOP OF VERTICAL BATTENFACADE TO FUTURE DETAIL.
FALLS TOGUTTER
FALLS TOGUTTER
FALLS TOGUTTER
FALLS TOGUTTER
FALLS TOGUTTER
FALLS TOGUTTER
BOX
GUT
TER
WITH
FA
LLS
TO S
UMPS
. REF
ER T
O H
YDRA
ULIC
DRA
WIN
GS.
BOX
GUT
TER
WITH
FA
LLS
TO S
UMPS
. REF
ER T
O H
YDRA
ULIC
DRA
WIN
GS.
REFER TO HYDRAULICDRAWINGS FOR FALLS &DRAINAGE
ELEV.A202
4
ELEV. 3A201A301
A
A301A
ELEV
.1
A20
1
A302C
A302B
A302C
A302B
ELEV
.A
2012
GC D F HA B IEA.1
C.1 C.2G.1
G.2 G.3 I.1D.1
4100 550 1965 1960 3175 1400 6080 625 905 4570 1050 1025 3075 4475 2100 1960 940 6175
2
3
5
4
1
2.3
3.2
7025
6225
5675
7025
1325
775
100
95
1.1
3.1
5
1
2
4
2.1
1.2
1.3
4.1
1.4
2.2
3.2
100
1000
1000
1980
2450
4665
4260
3890
3045
3980
595
410
775
95
46130BOUNDARY
2824
5BO
UND
ARY
5695
BUIL
DIN
G15
480
ROO
F TO
P D
ECK
7025
BUIL
DIN
G
1835
ROO
F D
ECK
4700
STA
IRS
100
2000
LIFT
100
950
DUC
T26
00ST
ORE
5695
BUIL
DIN
G
11355ROOF TOP DECK
5500BUILDING
20
4000SETBACK
5500BUILDING
24630ROOF TOP DECK
8000BUILDING
4000SETBACK
2025
4000SETBACK
8000BUILDING
4000SETBACK
2375STAIRS/ LIFT
1500STORE
200 200 1008900
ROOF TOP DECK
200
1765
ROO
F D
ECK
1076
5RO
OF
TOP
DEC
K
3550
ATR
IUM
RO
OF
7105
BUIL
DIN
G25
GRID
BOUNDARY
BUILDING SETOUT
GRI
D
BOUN
DA
RY
BUIL
DIN
G S
ETO
UT
ROO
MS
ROO
MS
GRI
DS
ROOMS
ARTIFICIALLAWN
ARTIFICIALLAWN
ARTIFICIALLAWN
REFER TO HYDRAULICDRAWINGS FOR FALLS &DRAINAGE
ROOF
ROOF BELOW
ROOF BELOW
ROOF BELOW ROOF BELOW
ROOF BELOW
FR
1100 HT PARAPETWALL
1100 HT PARAPETWALL
1100 HT PARAPETWALL
D07
9060CANTILEVER PORTION
795
CANTILEVER
1440
1545
NO
M
LIFT
METALPLANTER
METALPLANTER
METALPLANTER
METALPLANTER
METALPLANTER
METALPLANTER
METALPLANTER
METALPLANTER
METALPLANTER
OPEN
REFER TO LANDSCAPINGPLAN A702 FOR PLANTSPECIES ALLOCATION
REFER TO LANDSCAPINGPLAN A702 FOR PLANTSPECIES ALLOCATION
Project Name
Project Number
Scale
Title
Drawing Number
Date
Issue
DO NOT SCALE FROM THIS DRAWING.THIS DRAWING IS FOR READING PURPOSES ONLY.
Issue. Issue Description.By Date.
P MWA ISSUE FOR BUILDING PERMIT 11/04/16
Q MWA 2ND LIFT + SHORT STAY AMENDMENTS 09/05/16
R MWA 2ND LIFT + SHORT STAY AMENDMENTS 16/05/16
FR = FIRE RATED DOOR _/60/30
STRUCTURAL ELEMENT - PRECAST CONC -PROVIDE LINING TO ELEMENTAPPROPRIATE TO LOCATION/SITUATION TOMATCH ADJACENT FINISHES TO ACHIEVEFRL 120/60/30
PARTY WALL - NON LOAD BEARING -X2 ROWS OF STEEL STUDS @ 600mm CTSMAX WITH 20mm ROW GAP WITHINSULATION & WALL LININGS TO ACHIEVE90/90/90 & Rw+Ctr >50. WALLSSEPARATING SHOPS 34 & 35 FROM ENTRYLOBBY TO ACHIEVE 120/120/120
STUD WALL - NON LOAD BEARING96mm HEAVY DUTY STEEL FRAMEWORK.AIRCELL INSULATION WITH 16mmFYRCHECK INTERNAL & 9mm CFC SHEETEXTERNAL LINING WITH VILLA SAND FINISH.WALLS TO ACHIEVE Rw+Ctr >50, & WHEREWITHIN 3m OF SIDE BOUNDARY OR ARE ASOLE OCCUPANCY UNIT WALL TO ACOMMON CORRIDOR, LOBBY ORSTAIRWELL; TO ACHIEVE FRL -/90/90
150 PRECAST CONC WALL -TO STRUCTURAL ENGINEERSREQUIREMENTS WITH BULK + FOIL SIDEDINSULATION & ANTI GLARE WITHPLASTERB'D LINING TO INTERNAL SIDE.WALLS TO ACHIEVE FRL 120/60/30 &Rw+Ctr >50.
250 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTS.WALLS TO ACHIEVE FRL 120/60/30
PACKING -PROVIDE PACKING & LINING TO WALL TOBE FLUSH WITH & TO MATCH ADJACENTWALLS FINISHES
NOTES:
1. BUILDER TO CHECK ALL DIMENSIONS ON SITE PRIOR TOCOMMENCING CONSTRUCTION.
2. ARCHITECTURAL DRAWINGS ARE TO BE READ INCONJUNCTION WITH ALL RELEVANT CONSULTANTSDRAWINGS.
3. ALL BUILDING WORKS TO BE EXECUTED INACCORDANCE WITH AUSTRALIAN STANDARDS,BUILDING CODE OF AUSTRALIA & LOCAL & REGULATORYAUTHORITIES.
4. BUILDER TO NOTIFY ARCHITECT IMMEDIATELY OF ANYSERVICE LOCATION DISCREPANCIES OR CLASHES ONSITE.
STUD WALL - INTERNAL PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm PLASTERB'DLINING EACH SIDE & PAINT FINISH
STUD WALL - WET AREA PARTITIONS -76mm STEEL STUD FRAMEWORK. BULKINSULATION WITH 10mm WATER RESISTANTPLASTERB'D LINING & PAINT FINISH, ORVILLA BOARD & TILES TO WET AREA SIDE.
200 PRECAST CONC WALL -TO STRUCTURAL ENG'S REQUIREMENTSWITH PLASTERB'D LINING TO INTERNALSIDE (TO UNITS). WALLS TO ACHIEVE FRL120/60/30
STORE ROOMS - STUD WALL -STUD FRAMED WALLS TO 2100 HT WITHCHAINWIRE MESH & METAL FRAMINGABOVE
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
TYPE 7
TYPE 8
TYPE 9
TYPE 10
BALCONY PARTITIONS - STUD WALL -STEEL STUD FRAMED WALLS TO FULL HTWITH 1X CFC/BLUE BOARD LINING BOTHSIDES & ACRATEX FINISHTYPE 11
TYPE 12
LIFT/STAIR CORE - AFS WALL150 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISHTYPE 13
LIFT/STAIR CORE - AFS WALL262 AFS WALL TO STRUCTURAL ENGINEER'SREQUIREMENTS. TO ACHIEVE FRL 120/60/30- PAINT FINISH
S MWA ISSUE FOR CONSTRUCTION 24/06/16
T MWA PRECAST RISER DUCTS ADDED TO CORE 13/07/16
U MWA AS BUILT 22/08/17
V MWA AS BUILT CONDITIONS 03/10/17
Z1 MWA AS BUILT CONDITIONS 17/11/17
AutoCAD SHX Text283 - 285 VINCENT STREET
AutoCAD SHX TextJULY 2017
AutoCAD SHX Text1:100
AutoCAD SHX TextZ1
AutoCAD SHX TextA108
AutoCAD SHX Text16.04
AutoCAD SHX TextROOFTOP PLAN (LEVEL SIX)
AutoCAD SHX TextLEEDERVILLE
AutoCAD SHX TextMIXED-USE DEVELOPMENT
-
ELEVATION 2SCALE 1:100
LINE OF EXISTING GROUND LEVELAT BOUNDARY, SHOWN DASHED.
BOUN
DA
RY
BOUN
DA
RY
CFC CLAD SUPPORTSTRUCTURE WITHACRATEX FINISH
ALUMINIUM BLADE SCREENINGPOWDER COAT FINISH
P1P1P1
P1
P1
P1
P1
CS1
CS1 CS1P1 P1
P1
P1
GL14
GL14GL12
GL12
GL12
GL12
GL12
GL12
GL12
GL12
GL12
GL12
GL12
GL12
GL20
GL20
GL20
GL14
GL14
GL14
P3 P3
ALUMINIUM BLADE SCREENINGPOWDER COAT FINISH
ALUMINIUM BLADE GATE
OPEN
SLIDING SECURITY GATE.ALUMINIUM BLADES - POWDERCOAT FINISH
FULL HEIGHT ALUMINIUM BLADESCREENING TO SLAB SOFFIT.POLISHED ANODISED FINISH
FULL HEIGHT ALUMINIUM BLADESCREENING TO SLAB SOFFIT.POLISHED ANODISED FINISH
ALUMINIUM BLADESLIDING GATE. POLISHEDANODISED FINISH
ALUMINIUM BLADESLIDING GATE. POLISHEDANODISED FINISH
REFER TO A701 FOR LANDSCAPE& SCREENING/PLANTER DETAILS
150W X 50D X 3,500HALUMINIUM SCREEN
BLADES. POWDERCOAT FINISH (SILVER)
ELEVATION 1SCALE 1:100
BOUN
DA
RY
BOUN
DA
RY11
0017
0013
0021
5060
0
6850
BRICK FEATURE WALL.
SELECTED SUBWAY TILES TOENTRY COVE
STEEL RHS BATTENSWITH SELECTED TIMBER
LOOK FINISH
CFC CLAD SUPPORTSTRUCTURE WITHACRATEX FINISH
METAL LETTERBOXES SETINTO TILED BLOCKWORKWALL
STEEL SHS COLUMN. PAINT FINISHAS SPECIFIED
STEEL STRUCTURE CANOPY WITHMETAL ROOF SHEETING, CFC
SOFFIT & ULTRABOND FASCIA
CS2 CS2
P4
P4
OPEN
P3
SB1
BLOCKWORK PLANTER. RENDER &PAINT FINISH
HDG
P5 PAINT TO STEEL PLATE CASTINTO L1 SLAB EDGE
P3
P3
CS2
REFER TO A701 FOR LANDSCAPEDETAILS
REFER TO A701 FOR LANDSCAPEDETAILS
Project Name
Project Number
Scale
Title
Drawing Number
Date
Issue
DO NOT SCALE FROM THIS DRAWING.THIS DRAWING IS FOR READING PURPOSES ONLY.
Issue. Issue Description.By Date.
P MWA ISSUE FOR CONSTRUCTION 27/06/16
Q MWA L2 FACADE SET BACK 500mm 21/07/16
R MWA FINISHED AMENDED 24/11/16
S MWA FINISHED AMENDED 11/01/17
T MWA AS BUILT 21/08/17
U MWA PROPOSED SCREENING TO SOUTH 03/10/17
Z1 MWA AS BUILT CONDITIONS 17/11/17
AutoCAD SHX Text283 - 285 VINCENT STREET
AutoCAD SHX TextAUG 2017
AutoCAD SHX Text1:100
AutoCAD SHX TextZ1
AutoCAD SHX TextA201
AutoCAD SHX Text16.04
AutoCAD SHX TextELEVATIONS
AutoCAD SHX TextLEEDERVILLE
AutoCAD SHX TextMIXED-USE DEVELOPMENT
-
ELEVATION 4SCALE 1:100
BOUN
DA
RY
BOUN
DA
RY
P4
ACRATEX FINISH TOEXTENT OF VISIBLE FROMVINCENT STREET
CS1
ACRATEX PAINT TO RETURNALONG BOUNDARY TO MEETNEIGHBORING BUILDING
P2
P1
P1
P1
P1
P1
P3
P3
GL24
GL21
GL21
GL21
GL14
GL14
GL14
GL14
GL23GL23 GL23 GL23
P1
P1
P1
P1
P1
P4
AL03
AA405
BA405
CA405
ELEVATION 3SCALE 1:100
BOUN
DA
RY
BOUN
DA
RY
GL24
GL21
GL21
GL21
GL15
GL15
GL15 GL15
GL15
GL15
GL15
P4
P1
P1 P1
P2
ACRATEX FINISH TOEXTENT OF VISIBLE FROM
ROW
ACRATEX FINISH TOEXTENT OF VISIBLE FROMVINCENT STREET
APPROX LINE OF NEIGHBORING BUILDING
APPROX LINE OF NEIGHBORING BUILDING
P1
P1
PAINT FINISH TO RETURNALONG BOUNDARY TO MEETNEIGHBORING BUILDING
CS1
ACRATEX PAINT TO RETURNALONG BOUNDARY TO MEET
NEIGHBORING BUILDING
P3
P1
P1
P4
AL02
AA405
BA405
CA405
P3
P3
SLIDING SECURITY GATE.ALUMINIUM BLADES ANDFRAMING - POWDER COAT FINISH
Project Name
Project Number
Scale
Title
Drawing Number
Date
Issue
DO NOT SCALE FROM THIS DRAWING.THIS DRAWING IS FOR READING PURPOSES ONLY.
Issue. Issue Description.By Date.
O MWA ISSUE FOR BUILDING PERMIT 29/03/16
P MWA ISSUE FOR CONSTRUCTION 27/06/16
Q MWA L2 FACADE SET BACK 500mm 21/07/16
R MWA FINISHES AMENDED 24/11/16
S MWA AS BUILT 21/08/17
T MWA AS BUILT CONDITIONS 03/10/17
Z1 MWA AS BUILT CONDITIONS 17/11/17
AutoCAD SHX Text283 - 285 VINCENT STREET
AutoCAD SHX TextAUG 2017
AutoCAD SHX Text1:100
AutoCAD SHX TextZ1
AutoCAD SHX TextA202
AutoCAD SHX Text16.04
AutoCAD SHX TextELEVATIONS
AutoCAD SHX TextLEEDERVILLE
AutoCAD SHX TextMIXED-USE DEVELOPMENT
-
1.1
3.1
5
1
2
4
2.1
1.2
1.3
4.1
1.4
2.2
3.2
100
1000
1000
1980
2450
4665
4260
3890
3045
3980
595
410
775
95
1:20
1:20
1:8
1:8
1:4
1:4
RAMP UP - 1:4
RAMP DOWN - 1:4 1:8
1:8
RAMP UP - 1:16
(UNIT 34)
LOBBYTILES
STAIRS 1
ACCESSTOILET
TILES
UP
DN
RESIDENTIALBIN STORE
CONCRETE
COMM.BIN STORE
CONCRETE
STORE U. 4
CONCRETE
STORE U. 10
CONCRETE
STORE U. 11
CONCRETE
STORE U. 3
CONCRETE
STORE U. 2
CONCRETE
STORE U. 1
CONCRETE
STORE U. 5
CONCRETE
STORE U. 6
CONCRETE
STOREU. 7
CONCRETE
SHOPUNIT 35CONCRETE
CAR PARK13 BAYSCONCRETE
89 7 6 5 4 3 2 1
V V1110
5 BIKE RACKS
GROUND FLOOR PLAN
EOTTILES
BASEMENT RAMPCONCRETE
600 HIGH RAISEDMASONRY PLANTER.
600 HIGH RAISEDMASONRY PLANTER.
ENTRYTILES
FORECOURTTILES
PASSAGETILES
RAMPCONCRETE
GC D F HA B IEA.1
C.1 C.2G.1
G.2 G.3 I.1D.1
4100 550 1965 1960 3175 1400 6080 625 905 4570 1050 1025 3075 4475 2100 1960 940 6175
14.900 F.L
14.900 F.L
14.900 F.L
14.9
00 F
.L
PLANTER
ELECTRICAL AND COMMS TOELECTRICAL CONSULTANTS
REQUIREMENTS.
BANK OF WALL MOUNDED WATERMETERS, NOM. 4500 x 2000 INACCORDANCE WITHHYDRAULIC DRAWINGS.
ELEV.A202
4
ELEV. 3A201A301
A
A301A
2
3
5
4
1
2.3
3.2
7025
6225
5675
7025
1325
775
100
95
BUILDING OVERSHOWN DASHED.
15.825 F.L
14.900 F.L
16.4
50 F
.L
STA
IRS
4
LETT
ER B
OXE
S
LV KIOSK1400 X 800W
WASHPOINT
SC1
GL7
GL6
GL5
GL4
GL1
GL3