the ecological stretch ceiling - barrisolthe barrisol® stretch ceiling. sensitive and respectful of...
TRANSCRIPT
T H E E C O L O G I C A L S T R E T C H C E I L I N G
EcologyIt is our nature to preserve
Beige
White
G
rey
Black
Presentation
recycledThesecharacteristicsmakethemidealfor100%ecologicalconstructionsuchas“greenbuildings”,andarebasedon5criteria:site,water,energy,materialsandtheinteriorenvironment.
“TheRecycled”sheetingcanbeinstalledin bui ldings cert i f ied “sustainabledevelopment”andalsoinalltypesofconstructionwhichcontributetotheprotectionoftheenvironment.
The”recycled” LineofBarrisol isanother step in the company’scommi tment fo r sus ta inab le
development.
Aestheticism and performanceThesheetsin«TheRecycled«lineareavailableinfourcolors.Roundorsquareaestheticperforationscanbemadeonthesheeting.
WithMicroperforations,therecycledsheetsareidealtooptimizetheacoustics.
Sustainable developmentAswithallotherBarrisol®sheets,therecycledsheetsare100%recyclable.Furthermore,«TheRecycled»sheetingismadefromrecycledBarrisolsheets.
Beige
White
G
rey
Black
R02
R03
R04
Acoustics®Colors Perforated®
Microperf
Acoperf
Microacoustic
A10+ refØ 0,1 mm
A20+ refØ 0,15 mm
A30+ refØ 0,2 mm
MiniperfA40+ refØ 0,5 mm
R01
Omégaperf
Mediperf
Solaperf
P10+ refØ 1 mm
P50+ refØ 2,8 mm
MezzoperfP20+ refØ 1 mm
□ 4,5 mmP80+ ref
Maxiperf
Megaperf
P60+ refØ 4 mm
P70+ refØ 4 mm
Interior use
Composition 50% recycled materials - 50% virgin PVC
Fire classification M1 ( France ), Bs2 d0 in Europe
Hygrometric Degree < 65 % HR = 0,0030 g/h m ² Hg; > 65 % HR = 0,0045 g/h m ² mm Hg
Width 200 cm
Weight in m2 240 g ± 5 %
Thickness 0,18 mm ± 5 %
Break resistance longitudinal: 196,50 kg / cm ²; transversal: 220,80 kg / cm ²
Lengthening break resistance longitudinal: 231 %; transversal: 309 %
Tear resistance longitudinal: R = 1,60 dN, Is = 170 %; transversal: R = 2,00 dN, Is = 255 %
Dimensional stability -15°C in +45°C
Memory of the material shape Memory
TECHNICAL INFORMATION
Advantages of BARRISOL®:
•Sheeting is 100 % recyclable. Re-usable in other
kindofproducts (hose,publicbenches, variousplastic
objects).
•“TheRecycled“lineofsheetingismadefromrecycled
Barrisol®sheets.
•Profilesandstructuresare100%recyclable.
•Uses 20 times fewer resources when compared to
classicbuildingmaterials.
•Washable,doesnotrequirepainting.
•Canbetakenupanddowneasily,withoutdamaging
thematerialthusimprovingaccessibility.
•Morethan20yearlifespan.
•Theproductionprocessusesnowater.
•NoemissionofCFCorHCFC.
•Cadmiumfree.
•Packagingmaterialsare100%recyclable.
•Meets the European standards: B1, M1, Class 1,
Class0,B-s2,d0.
•MeetstheUSstandards:Class1,ULcertified.
Weremainatyourservicetotakebackanyremovedor
replacedceilingstoassuretheirrecycling*.
*Please, contact us to know the terms
More than 35 years ago, I began my great adventure of creating
the BARRISOL® stretch ceiling.
Sensitive and respectful of preserving the environment
since my early childhood, I searched for materials to work with that would preserve nature.
Since inception, Barrisol has evolved from this very
notion-an environmentally sound tool capable of creating stretch ceilings
of unprecedented aesthetics.
By reducing the use of resources by up to 95% when compared to
conventional building practices, I’ve managed to maintain
my childhood convictions of preservation while
enhancing the architectural world around us.
BARRISOL® is recommended by the greatest architectural firms,
not only because of the techniques and aesthetics but also
because of respect for the environment and nature. Environmentally Yours,Fernand SCHERRER
“
”
“In order to make the world of tomorrow more beautiful, you first need to work to preserve theworld today.”
Lightweight ( 180g / m2 ), Barrisol® stretch ceilings are easy to transport. The costs of transportion and Fuel consumption are low.Barrisol® sheets are recyclable, do not need to be painted and their lifespan exceeds 20 years. There is nearly no waste when the ceiling is mounted.
ASSEMBLY
Barrisol® Other types of ceilings
Assembly of 10 000 m² with 4 assembles 50 days 80 to 100 days
reduced costs hight need of energy
premises are quickly reusable
long building occupation
LOW NEED OF ENERGY
RECYCLING
Barrisol® Other types of ceilings
Recyclage 100 % recyclable sorting necessary
preserve the environment, rusable as energy source
non reusable waste (rubble)
100 % RECYCLABLE
TRANSPORTATION
Barrisol® Other types of ceilings
Transport of the material reduced volume significant volume
lighter vehicles large vehicles
less fuel consumed significant fuel consumption
GAINS IN WEIGHT & FUEL
PACKAGING
Barrisol® Other types of ceilings
for 10 000 m² 50 Kg more than 1 000 Kg
reduced packaging diverses natures
almost no waste lot of waste
Difference : NEARLY 1 TON
WEIGHT
Barrisol® Other types of ceilings
WeightWeight for 10 000 m2
500 g/m2
5 t12 Kg/m2
120 t
Difference : 115 tons of raw material less to cover a same surface of 10 000 m2
“In order to make the world of tomorrow more beautiful, you first need to work to preserve theworld today.”
ASSEMBLY
Barrisol® Other types of ceilings
Assembly of 10 000 m² with 4 assembles 50 days 80 to 100 days
reduced costs hight need of energy
premises are quickly reusable
long building occupation
LOW NEED OF ENERGY
RECYCLING
Barrisol® Other types of ceilings
Recyclage 100 % recyclable sorting necessary
preserve the environment, rusable as energy source
non reusable waste (rubble)
100 % RECYCLABLE
WASTE
Barrisol® Other types of ceilings
Waste generated by installation of 10 000 m² +/- 0 about 10 t
Waste generated by production of material +/- 0 10 %
ALMOST NO WASTE
DURABILITY
Barrisol® Other types of ceilings
20 years and mored 5 to 10 years
no regular renovation regular renovation
no dirt more dirt
no waste more waste
NO RENOVATION IS NEEDED
TRANSPORTATION
Barrisol® Other types of ceilings
Transport of the material reduced volume significant volume
lighter vehicles large vehicles
less fuel consumed significant fuel consumption
GAINS IN WEIGHT & FUEL
TABLE OF RESULTS
Limits Results GAZ (ppm)
Condition 1 Condition 2 Condition 3
Carbon monoxide CO 1450 30 30 300
Muriatic acid HC 600 0 0 0
Hydrogen bromide HBr 600 0 0 0
Hydrogen fluoride HF 600 0 0 0
Hydrogen cyanide HCN 140 0 0 0
Acid emanations NOx 350 5 0 0
Sulfur dioxide SO2 120 0 0 0
Specific optical densitycorrected average 200 103.2 94.9 140.3
INTERNATIONAL MARITIME ORGANIZATIONRESOLUTION MSC 61 ( 67 ) 1996
THE INTERNATIONAL CODE FOR APPLICATION OF FIRES TESTS PROCEDURESAppendix 1, Part 2
SMOKE AND TOXICITY TEST
SamplesofmaterialsweretestedforsmokeandtoxicitygenerationaccordingtotheFMOresolutions,MSC61(67)appendix1,part2.Thetestedsamplesreachedandmetthecriteriadefinedformaterialsusedassurfaceofwallandceilingasrequiredbytheresolution.
Note: this document, extracted from the BARRISOL® test “ International Code forApplicationofFiresTestsProcedures“isavailableinitsentiretyuponrequest.
Réf
. B86
0/01
44 -
Gys
s Im
p. -
10
000
ex -
10/
2009
- C
OP
YR
IGH
T ©
200
9 N
OR
MA
LU S
.A.S
. - T
ous
droi
ts r
éser
vés.
Cré
atio
n &
Con
cept
ion:
ser
vice
mar
ketin
g &
com
mun
icat
ion
BA
RR
ISO
L-N
OR
MA
LU S
.A.S
.
Your installer
BARRISOL-NORMALU S.A.S. - Route du Sipes - 68680 Kembs - FRANCETel. : +33 (0)3 89 83 20 20 - Fax : +33 (0)3 89 48 43 44 - Email : [email protected]
www.barrisol.com
Architectes : S. Gunst & Kristian Gavoille
1967
2007Membre du conseilUS pour les
Bâtiments «Verts»
Certificat de conformité CEEC - Certificate of conformityN° 0071 - CPD - 14627