the impulse “switch” 1daniel overman dis5274/10/2010

26
the Impulse “Switch” 1 Daniel Overman DIS527 4/10/2010

Upload: victoria-reed

Post on 23-Dec-2015

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 1

the Impulse “Switch”

4/10/2010

Page 2: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 2

What is an Impulse Switch?

• Impulse is an EMG (Electromyography) sensing switch i.e. senses tiny voluntary muscle contractions.

• Impulse detects and wirelessly transmits the EMG signal to a Bluetooth receiver.

• Specialized software in a Windows PC processes the signal as a traditional switch or click of the mouse.

• Combining this wireless connectivity with accessibility programs allows users to control their computer with the smallest of muscle activity.

4/10/2010

Page 3: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 3

The “Switch”

Indicator Light

Connection Button

The EMG sensor

Blue Tooth USB InterfaceDisposable Electrodes

4/10/2010

Page 4: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 4

Impulse States• Standby:

– Standby Mode occurs when the Impulse is charged, and no lights are on.

• Transmitting:– Transmitting Mode occurs when the Impulse is turned on and the blue

light flashes once every second.

• Pairing:– Pairing Mode occurs when the Impulse is being paired with a computer.

• Charging:– Charging Mode occurs when the Impulse is plugged into the charger.

4/10/2010

Page 5: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 5

Charging the Sensor

Impulse EMG Sensor

AC Power Charger

4/10/2010

Page 6: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 6

Charging

• Fully charge the Impulse prior to use.

• The Impulse needs to be put into Standby Mode in order to charge

• If the Impulse is not in Standby Mode during charge, it may cause undesirable operation.

• A red light indicates the device is connected to the charger.

• The red light will turn off when charge is complete.

4/10/2010

Page 7: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 7

Installation

• PC Compatibility: PC or compatible computer running Windows® XP (Service Pack 2) or Windows Vista™. Requires

• one available USB 2.0 or 1.1 port.

• Do not plug Bluetooth adapter in until prompted to do so.

• Close all software and disable anti-virus software.

• Insert Impulse CD and follow prompts. This will check and install the following programs:

– .NET

– Impulse Software

– Toshiba Bluetooth Stack (Bluetooth Driver)

4/10/2010

Page 8: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 8

Initial Setup

Impulse Software Window

Click “Link Manager” to Pairing Windowaccess the pairing window

4/10/2010

Page 9: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 9

Pairing Window

“Pair New” Button

4/10/2010

Page 10: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 10

Pairing the Impulse Sensor

• Start by click “Link Manager.”

• Click “Next” once the sensor is in Pairing Mode (blinking blue and red), and then click “Pair New” to begin pairing the sensor.

• Once the device is paired, the Impulse software will read “Connected” and the sensor will stop blinking red and blue.

4/10/2010

Page 11: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 11

Sensor Location

• The Impulse sensor should be placed over a muscle that the user has control of.

• The Impulse Sensor should be placed in the center of that muscle, parallel to the muscle fiber for optimum EMG sensing.

• Proper site preparation is essential to obtain a good EMG signal.

• See following examples

4/10/2010

Page 12: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 12

Forearm Position

4/10/2010

Page 13: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 13

Forehead Position

4/10/2010

Page 14: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 14

Jaw Position

4/10/2010

Page 15: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 15

Mounting sensor

4/10/2010

Page 16: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 16

Placing

• Electrodes are single use and disposable.

• The contact surfaces are pre-gelled with a hypo allergenic gel that is water soluble.

• When applying the electrode, it is critical to obtain a good skin to electrode contact.

• Hair can interfere with the contact.

• Clean the desired placement site with an alcohol wipe.

• Remove the adhesive backing from the electrode and place it securely on the user. (The metal snaps face away from the skin.)

• Snap the Impulse EMG sensor onto the electrode.4/10/2010

Page 17: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 17

Calibration

“Auto Calibrate” button

4/10/2010

Page 18: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 18

Auto Calibration

• Click “Auto Calibrate”

• When prompted, contract and relax the muscle site several times until the screen reads “Finished Calibrating”

• The EMG levels have now been determined.

• These settings will be saved and calibration should not be necessary on a daily basis.

• Note: If you have poor connection of the electrode to skin then the signal from the Impulse to the computer can take several minutes to stabilize.

4/10/2010

Page 19: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 19

Advance Settings

Impulse Software Window

Click “Advanced Settings” to access Advanced Settings4/10/2010

Page 20: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 20

Advance Settings

Advanced Settings Window

Simulated Actions with Primary Action

4/10/2010

Page 21: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 21

Assigning Functions

• Simulated Actions with Primary Activation:– Determines how you the Impulse responds when

you first activate.

• Simulated Actions with Secondary Activation:– Lets you change how you want the Impulse to

respond when you initiate 2nd level activation. (“Play Alarm” is selected by default).

4/10/2010

Page 22: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 22

Threshold AdjustmentLeft most + button will set the threshold bar by increments of 10.

Right most + button will set the threshold bar by increments of 1.

Color Dot:Blue – Not Activating Primary ActivationRed – Activating Primary ActivationThreshold number can be set from 1 to 100.

Right most - button will set the threshold bar by decrementsof 1.

Left most - button will set the threshold bar by decrementsof 10.

4/10/2010

Page 23: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 23

Impulse Help• Manual Button:

– Launches PDF manual that is installed on your computer.

• Email Support:

– Launches your email client with AbleNet’s Impulse Technical Support email address in the “To” field. We will

• Contact Information:

– Call Technical Support during normal business hours for support. If needed a qualified technician can connect remotely to your computer to assist you using the “Request Remote Support” link.

• Request Remote Support:

– Allows a qualified technician to assist with setting up the Impulse software. This link will give the technician the ability to control your computer remotely.

4/10/2010

Page 24: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 24

Advanced Features not Presented

• Advanced Calibration

• 2nd Level Activation (Alarm Input)

• Advanced Settings

4/10/2010

Page 25: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 25

Summary• If you have never done a Windows PC device install, it’s likely you will need Tech

Support

• If experienced with device installation…this may be a little tricky but nothing unusual.– place sensor in transmit mode and not connected to the consumer before launching Impulse

software.

• Actual program displays and controls may be unfamiliar to non-technical users.

• Installation and initial debug required about three hours…for me

• This is a sophisticated high tech device that provides “switch” activation from only the slightest of muscle movement.

• The “price” and “prize” are appropriately proportional!

4/10/2010

Page 26: The Impulse “Switch” 1Daniel Overman DIS5274/10/2010

Daniel Overman DIS527 26

On Screen Demo• On Screen Keyboard

– http://www.imgpresents.com/

• Camera Mouse– http://www.cameramouse.org/

• Impulse Switch– http://www.ablenetinc.com/

4/10/2010