the latest fire test procedures for ao & ho multi cable ... multi cable and pipe transits the...
TRANSCRIPT
Nofirno Multi Cable and Pipe Transits The latest fire test procedures for AO & HO multi cable transits and pipe penetrations
CSD Sealing Systems are the UK market leaders in the supply of cable and pipe sealing systems for the marine and offshore industries, having extensive experience and knowledge of supplying offshore engineers with specialist sealing solutions for over 20 years. The systems enhance the integrity of fire, gas and watertight boundaries when penetrating with pipes or cables and are proven in the North Sea on major upgrade projects for Statoil, Norsk Hydro, Shell, BP, Talisman and ConocoPhillips.
The RISE NOFIRNO Multi cable transit and RISE NOFIRNO pipe penetration systems have been tested in accordance with the IMO 2010 FTP Code to prove integrity in “A-0” and “H-0” without any insulation applied.
The new IMO International Code for Application of Fire Test Procedures, 201 0 (201 0 FTP Code), took effect from 1 July 2012 and addresses the importance of separate fire tests for pipe penetrations and cable transits through “A-0” divisions and “A-60” divisions;
Many sub divisions within a modern ship and offshore platforms are classified under IMO SOLAS 74 and IMO MODU (2009) as “A-0” and “H-0” where there is a risk of hydrocarbon fire. It is vitally important that pipe penetrations and cable transits are installed as tested in “A-0” and “H-0” divisions and any insulation (if required and applied in the fire test) is also then applied in practice.
An “A-0” test is more difficult for a pipe penetration and cable transit to pass, since there is normally no fire insulation fitted on an “A-0” division. The penetration and cable transit is subjected to a far greater heat load because of the tremendous amount of radiated heat in addition to the normal conducted heat as shown in the image above. This increased heat load could then result in integrity failure with fire breaking through a pipe penetration or cable transit within the 60 minutes.
All “A” class fire tests are for a duration of 60 minutes, “A-60” divisions are required to maintain the insulation & integrity for 60 minutes and “A-0” divisions must still contain a fire (integrity) for 60 minutes but because we are not concerned about temperature rise (insulation) there is normally no insulation applied. The only way many “A-60” approved systems can pass the “A-0” fire test is if they are locally insulated to protect them; this is not always then applied in the field.
The previous FTP code only made reference to “A” class divisions, any testing on “A-60” divisions was assumed to satisfy the criteria for all “A” class divisions including: “A-0”; certificates were issued for “A-0 - A-60” on the basis of “A-60” testing (but drawings showed insulation applied), there were no separate tests required for “A-0” divisions.
This distinction is now much clearer. Extracts from The new IMO International Code for Application of Fire Test Procedures, 2010 (201 0 FTP Code);
Cable Solutions Worldwide LtdCraigearn Business ParkMorrison Way, KintoreAberdeenshire, AB51 0TH
e [email protected] 1467 633790 (tel)44 1467 631284 (fax)1st4cables.com
Pipe and duct penetrations
“A-0” class pipe penetrations are recommended to be performed in an uninsulated (“A-0”) bulkhead/deck. If the pipe penetrations are tested as an “A-60” class penetration, any insulation fitted (on the penetration itself and 200 mm around) will be required to be fitted also for class “A-60”. “A-0” penetrations shall not be approved without an “A-0” test although tested and approved as “A-60”.
Cable Transits
“A-0” class cable transits are recommended to beperformed in an uninsulated (“A-0”) bulkhead/deck. If the cable transits are tested as “A-60” penetration, any insulation fitted on an exposed side (on the cable transits itself and 200 mm around) will be required to be fitted also for “A-0”. “A-0” cable transits shall not be approved without an “A-0” test although tested and approved as “A-60”.
Golden Eagle Development Offshore Oil Platforms
UK North Sea CB&I/Nexen -supply RISE NOFIRNO system, sealing 970 pipe penetrations across both platforms to protect against hydrocarbon jet fires J30/ H60 and blast overpressures of 1 bar.
Shell Upgrade Program
RISE NOFIRNO system used to replace original pipe penetration seals over 13 platforms, (average of approximately 250 pipe penetrations per platform) to prevent corrosion; AO - A60 & HO- H120 rated.
Projects Benefits
RISE NOFIRNO flexible pipe penetration system is one of the most adaptive systems for sealing straight and angled pipe penetrations and can even accommodate multiple pipe runs, significantly saving in space. The system remains elastic and can therefore accommodate significant pipe movement in all directions.
SLIPSIL Plug pipe penetration combines simple installation with high performance sealing.
Certified for use in all A) - A60 & H0 - H120 bulkheads and decks
Certified for use in all A0 - A60 & H0 - H120 bulkheads and decks, with no insulation required on fire hazard side
Certified for use in A-0 and H-0 areas without any additional insulation required
2 hour Jet Fire rated without any additional insulation & gas and watertight after an A60 fire test
Easy addition & removal of cables & up to 50% space saving over modular block style Multi Cable Transits
A-0 and H-0 areas without any additional insultation required
2 hour Jet Fire rated without any additional insulation & gas and watertight after an A-60 fire test
Prevents corrosion inside the penetration by preventing moisture build up inside the penetration seal
Remains elastic to accommodate movement between pipe systems and the structure, ensuring integrity is maintained throughout the life of the structure
RISE NOFIRNO Multi Cable Transit is one of the most flexible & safest systems for sealing cable transits.
ConocoPhillips Jasmine Platform (New Build)
Supplied RISE NOFIRNO system to seal 316 pipepenetrations with service pipes ranging from 26.7mm to 508mm, A60 & J30 rated.
BP
Andrew Redevelopment, Azeri & Magnus
Other Projects
Nexen
Buzzard
Talisman
Fulmar A, Montrose Alpha, Clyde, Claymore & Tartan
Apache
Forties Alpha, Forties Echo & Beryl Alpha
Amercable Gexol
Gexol® Insulated Oil & Gas Cables are the industry’s standard for premium power, control and instrumentation performance. Gexol cables prove their value daily in the punishing operating environments of offshore drilling and petroleum facilities around the world.
Offshore applications challenge cable construction with relentless heat, vibration, salt corrosion, drilling mud and mechanical stress. And reliability is a huge issue – because it’s a long, long way to the nearest cable warehouse. You can depend on Gexol Insulated Oil & Gas cables for safe, reliable performance in the harshest operating conditions.
Nexans AmerCable’s Gexol® (pronounced Jex-all) Oil & Gas cables are the industry standard for high quality Type P power, control, instrumentation and VFD cables.
Gexol cables are designed for mission-critical applications where reliable performance in extremely hazardous operating conditions is essential for worker safety and profitable production. Gexol cables prove their value daily in the punishing operating environments of offshore drilling and petroleum facilities around the world.
Value Benefits
Cable Solutions Worldwide LtdCraigearn Business ParkMorrison Way, KintoreAberdeenshire, AB51 0TH
e [email protected] 1467 633790 (tel)44 1467 631284 (fax)1st4cables.com
Power, control, instrumentation and VFD constructions
Highest ampacity ratings
Superior dielectric properties
Exceeds CSA cold bent/cold impact (-40°C/-35°C)
Drilling mud resistant
Oil resistant
Extremely flexible for easy installation and longerservice life
Shortest lead times and best on-time delivery
Severe Cold Durability
Exceeds CSA Cold Bend / Cold Impact (-40°C/-35°C)
Flame Retardant
Certified to IEC 92-3 (332-3A) and IEEE 1580
Drilling Mud Resistant Oil Resistant
CE-TEK Enclosures
CE-TEK’s products are made from a wide range of materials including: stainless steel, ABS, polycarbonate, GRP, die-cast aluminium and many more.
Certification is available to the latest ATEX/IEC Ex standards of EN 60079 and by constant development we are now able to manufacture enclosures to withstand fire conditions (950° C for 3 hours) and also for permanent submersion (IP68) to water depths of up to 3000 metres. CE-TEK have also successfully developed and manufactured a variety of bespoke enclosures to meet exacting customer and environmental requirements.
New developments include fully waterproof housings for plasma, LED and LCD screen televisions for outdoor use.
They are vandal proof and include a range of climatic solutions for variable weather conditions and can be made to size to suit any type of flat screen display.
Cable Solutions Worldwide LtdCraigearn Business ParkMorrison Way, KintoreAberdeenshire, AB51 0TH
e [email protected] 1467 633790 (tel)44 1467 631284 (fax)1st4cables.com
NEK606 BFOU RFOU
Cable Solutions Worldwide LtdCraigearn Business ParkMorrison Way, KintoreAberdeenshire, AB51 0TH
e [email protected] 1467 633790 (tel)44 1467 631284 (fax)1st4cables.com
Voltage Rating 3.6/6kV, 6/10kV, 8.7/15kV85
IEC 60092-354
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2Construction DetailsConductor Screen - Semi-conducting compound
Insulation - HF-EPR as per IEC 60092-351Fire proof layer - Mica tape
Insulation Screen - Semi-conducting compoundMetallic Screen - Tinned copper wire braid or Tinned Copper tapeInner Covering - Halogen-free compoundArmour - Tinned copper wire braidSheath - IEC 60092-359, SHF2
Applied StandardsNEK 606
IEC 60332-3 Cat. AFIEC 60754-1 & 2IEC 61034-2
BFOU BFCU NEK606 Type Cable
Voltage Rating 3.6/6KV, 6/10KV, 8.7/15KV85
IEC 60092-354
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2Construction DetailsConductor Screen - Semi-conducting compoundInsulation - HF-EPR as per IEC 60092-351Insulation Screen - Semi-conducting compoundMetallic Screen - Tinned copper wire braid or Tinned Copper tapeInner Covering - Halogen-free compoundArmour - Tinned copper wire braidSheath - IEC 60092-359, SHF2
Applied StandardsNEK 606IEC 60332-3 Cat. AFIEC 60754-1 & 2IEC 61034-2
RFOU RFCU NEK606 Type Cable
Voltage Rating 0.6/1kV85
IEC 60092-353
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2Construction DetailsInsulation - HF-EPR as per IEC 60092-351Inner Covering - Halogen-free compoundArmour - Tinned copper wire braidSheath - IEC 60092-359, SHF2
Applied StandardsNEK 606IEC 60332-3 Cat. AFIEC 60754-1 & 2IEC 61034-2
Voltage Rating 250V85
IEC 60092-3
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2Construction DetailsInsulation - HF-EPR as per IEC 60092-351Collective Screen - Copper or aluminium backed polyester tape with tinned copper drain wireInner Covering - Halogen-free compoundArmour - Tinned copper wire braidSheath - IEC 60092-359, SHF2
Applied StandardsNEK 606IEC 60332-3 Cat. AFIEC 60754-1 & 2IEC 61034-2
RFOU(c) RFCU(c) NEK606 Type CableVoltage Rating 250V
85
IEC 60092-3
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2Fire Proof Layer - Mica tape
Construction Details
Insulation - HF-EPR as per IEC 60092-351Collective Screen - Copper or aluminium backed polyester tape with tinned copper drain wireInner Covering - Halogen-free compoundArmour - Tinned copper wire braidSheath - IEC 60092-359, SHF2
Applied StandardsNEK 606IEC 60331IEC 60332-3 Cat. AFIEC 60754-1 & 2IEC 61034-2
BFOU(c) BFCU(c) NEK606 Type Cable
RFOU RFCU NEK606 Type Cable
Voltage Rating 0.6/1kV85
IEC 60092-353
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2Construction Details
Insulation - HF-EPR as per IEC 60092-351Fire Proof Layer - Mica tape
Inner Covering - Halogen-free compoundArmour - Tinned copper wire braidSheath - IEC 60092-359, SHF2
Applied StandardsNEK 606
IEC 60332-3 Cat. AFIEC 60331
IEC 60331
IEC 60754-1 & 2IEC 61034-2
BFOU BFCU NEK606 Type Cable
Voltage Rating 250V
85
IEC 60092-3
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2Construction Details
Insulation - HF-EPR as per IEC 60092-351
Individual Screen - Copper or aluminium backed polyester tape with tinned copper drain wire
Inner Covering - Halogen-free compound
Armour - Tinned copper wire braid
Sheath - IEC 60092-359, SHF2
Applied Standards
NEK 606
IEC 60332-3 Cat. AF
IEC 60754-1 & 2
IEC 61034-2
RFOU(i) RFCU(i) NEK606 Type Cable
Voltage Rating 250V
85
IEC 60092-3
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2Construction Details
Insulation - HF-EPR as per IEC 60092-351
Individual & Collective Screen - Copper or aluminium backed polyester tape with tinned copper drain wire
Inner Covering - Halogen-free compound
Armour - Tinned copper wire braid
Sheath - IEC 60092-359, SHF2
Applied Standards
NEK 606
IEC 60332-3 Cat. AF
IEC 60754-1 & 2
IEC 61034-2
RFOU(i/c) RFCU(i/c) NEK606 Type Cable
Voltage Rating 250V
85
IEC 60092-3
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2
Fire Proof Layer - Mica tape
Construction Details
Insulation - HF-EPR as per IEC 60092-351
Individual & Collective Screen - Copper or aluminium backed polyester tape with tinned copper drain wire
Inner Covering - Halogen-free compound
Armour - Tinned copper wire braid
Sheath - IEC 60092-359, SHF2
Applied Standards
NEK 606
IEC 60332-3 Cat. AF
IEC 60331
IEC 60754-1 & 2
IEC 61034-2
BFOU(i/c) BFCU(i/c) NEK606 Type CableVoltage Rating 250V
85
IEC 60092-3
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2
Fire Proof Layer - Mica tape
Construction Details
Insulation - HF-EPR as per IEC 60092-351
Individual Screen - Copper or aluminium backed polyester tape with tinned copper drain wire
Inner Covering - Halogen-free compound
Armour - Tinned copper wire braid
Sheath - IEC 60092-359, SHF2
Applied Standards
NEK 606
IEC 60332-3 Cat. AF
IEC 60331
IEC 60754-1 & 2
IEC 61034-2
BFOU(i) BFCU(i) NEK606 Type Cable
Voltage Rating 0.6/1kV
85
IEC 60092-3
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2Construction Details
Insulation - HF-EPR as per IEC 60092-351
Sheath - IEC 60092-359, SHF2
Applied Standards
NEK 606
IEC 60332-3 Cat. AF
IEC 60754-1 & 2
IEC 61034-2
RU NEK606 Type Cable
Voltage Rating 0.6/1kV
85
IEC 60092-353
Maximum Conductor Temperature
Conductor - IEC 60228 Class 2Construction Details
Insulation - IEC 60092-359, SHF2
Applied Standards
NEK 606
IEC 60332-3 Cat. AF
IEC 60754-1 & 2
IEC 61034-2
UX NEK606 Type Cable
Top Drive Service Loops
Nexans AmerCable manufactures OEM-quality serviceloops and supplies them to you without OEM hassles.All land and offshore drilling top drive service loopsare engineered and produced at our state-of-the-artcable and service loop production facilities.
Value Benefits
Standard loop packages for NOV (VARCO), Tescoand Can Rig
Custom Loop Designs
Nexans AmerCable offers custom engineered service loop solutions that deliver higher levels of safety and productivity.
NOV, VARCO, TDX, TDS, and IDS are trademarks owned by National Oilwell Varco, LP or its related entities. Nexans AmerCable is not affiliated with National Oilwell Varco or its related entities.
TESCO and its associated trademarks are trademarks owned by Tesco Corporation or its related entities. Nexans AmerCable is not affiliated with Tesco Corporation or its related entities.
CANRIG and its associated trademarks are trademarks owned by Canrig Drilling Technology Inc. or its related entities. Nexans AmerCable is not affiliated with Canrig Drilling Technology Inc. or its related entities.
Cable Solutions Worldwide LtdCraigearn Business ParkMorrison Way, KintoreAberdeenshire, AB51 0TH
e [email protected] 1467 633790 (tel)44 1467 631284 (fax)1st4cables.com
Potted or non-potted
300V – 15kV AC
DC Power
Instrumentation
Composite Power & Control
Thermocouple
Fiber Optic
Electro-Optic
Available with or without quick disconnects
Core bundles, which are specifically designed for service loops, are expertly produced at our 500,000 sq. ft. El Dorado, Arkansas cable manufacturing facility.
Nexans AmerCable has been producing top drive service loops since 1993. Our professionally engineered service loops are built to withstand the hazardous operating conditions and dynamic stress of land drilling operations.
Service loops are completed at our 80,000 sq. ft.manufacturing facility in Houston, Texas. Bundles areinserted in hoses and fully potted (non-potted also available). Our highly experienced technicians add couplers/connectors as specified, then each loop is computer tested and packaged in weatherproof containers.
With Nexans AmerCable you can expect:Nexans AmerCable offers a standard line of top driveservice loop packages, including:
Short lead times
Standard Gexol® cables
Low smoke halogen-free
CIR® – Crush & Impact Resistant (without external armoring)
CIR® Arctic Grade – for extreme cold operating conditions
VFD cables - five constructions
GexSIS-125 switchboard wire
DLO
Reliable on-time delivery
Outstanding engineering and technical support
Great customer service
Cables are available in a variety of constructions, including:
NOV (VARCO)
TDS – 11
TDS – 9
TDS – 10
TDS – 3
TDS – 8
IDS
PS2
(Conversion Kit from loose cables to hanging loop)
TESCO
All Makes & Models
CANRIG
All Makes & Models
QFCI MUD Resistant Fibre Optic Cable - Fire Resistant / MUD Resistant / Flame Retardant / Halogen Free / DNV approved
QFCI MUD ResistantFibre Optic Cable - Fire Resistant / Flame Retardant / Halogen Free / NEK 606 code F1
Cable Solutions Worldwide LtdCraigearn Business ParkMorrison Way, KintoreAberdeenshire, AB51 0TH
e [email protected] 1467 633790 (tel)44 1467 631284 (fax)1st4cables.com
Central Strength Member Steel strength member or glass fibre reinforced plastic (FRP)
Thermoplastic material (PBT), jelly filled
Fire resistant mica/glass tapes
EIA/TIA 598
1 - Red / 2 - Green - others White
Thermoplastic rods
Loose tubes (and fillers) are stranded around a steel strength member
Black LSZH compound
Galvanised Steel Wire Braid (GSWB)
Black LSZH compound
Loose Tube
Fire Barrier
Fibre Colour Code
Tubes Colour Code
Filler Elements
Cable Core
Inner Jacket
Metallic Armour
Outer Jacket 1
SHF2 compound (mud, oil, hydrocarbon resistant and UV stabilized)
Outer Jacket 2
Product Specifications - Physical Characteristics
Central Strength Member Steel strength member or glass fibre reinforced plastic (FRP)
Thermoplastic material (PBT), jelly filled
Fire resistant mica/glass tapes
EIA/TIA 598
1 - Red / 2 - Green - others White
Thermoplastic rods
Loose tubes (and fillers) are stranded around a steel strength member
Black LSZH compound
Galvanised Steel Wire Braid (GSWB)
Black LSZH compound
Loose Tube
Fire Barrier
Fibre Colour Code
Tubes Colour Code
Filler Elements
Cable Core
Inner Jacket
Metallic Armour
Outer Jacket 1
Product Specifications - Physical Characteristics
Cable Solutions Worldwide, stock and distribute Cat 5e Data cables designed for Marine and Offshore applications. All cables are offered with a Galvanised Steel Wire Braid and a choice of either a standard LSOH jacket or a mud resistant LSOH Polyurethane Jacket. The PU jacket offers enhanced chemical and mud resistance.
Cat 5e Offshore Grade
Data Cables
Cable Solutions Worldwide, stock and distribute Profibus DP and Profibus PA cable designed for Marine and Offshore applications. All cables are offered with a Galvanised Steel Wire Braid and a choice of either a standard LSOH jacket or a mud resistant LSOH Polyurethane Jacket.
Profibus Marine Grade
Cable Solution’s knowledge and experience of their customers requirements combined with the technical expertise “in-house”, has meant that these specialised products are the fastest growing part of Cable Solutions’ product portfolio.
We are specialising in pre-terminated fibre assemblies to operate reliably in the most harsh of environments both on and offshore. Pre-terminated versions with any combination of cores or armouring arrangements are available on any part of the globe within days. These can be made to any length with full protection to ensure the job gets done.
Cable Solutions Worldwide, stock and distribute Fibre Optic cables designed for Marine and Offshore applications. All cables are offered with a Galvanised Steel Wire Braid and a choice of either a standard LSOH jacket or a mud resistant LSOH PolyurethaneJacket. Please download an example of the datasheet for a 12 core fibre. These are stocked in either 4, 8, 12, 24 or 48 fibre configerations. the diameter of the cable remains the same whichever one you choose. The PU jacket offers enhanced chemical and mud resistance.
We also supply all of the patch panels to suit, loaded or blank and a full range of SC and ST type connectors and the test equipment to suit.
Fibre Optic Products & Assemblies
Cable Solutions, stock and distribute Cat 6 Data cable designed for offshore applications. FTP (Screened) & UTP (unscreened) versions are available and all cables are offered with a Galvanised Steel Wire Braid or tinned Copper Wire Braid and a choice of either a standard LSOH jacket or a mud resistant LSOH Polyurethane Jacket. The PU jacket offers enhanced chemical and mud resistance.
Cat 6 Offshore Grade
Cable Solutions Worldwide, stock and distribute Cat 7 Datacable designed for Marine and Offshore applications. All cables are offered with a Galvanised Steel Wire Braid and a choice of either a standard LSOH jacket or a mud resistant LSOH Polyurethane Jacket. The PU jacket offers enhanced chemical and mud resistance.
Cat 7 Offshore Grade
Subsea Bespoke Cable Manufacture
Our composite cables are designed using high spec stranded wire for the best flexibility in dynamic applications. Whether its for Instrumentation, Fibre optic, Power or control, Cable Solutions can provide an in-house designed cable specification to suit your exact requirements with MOQ’s as low as 100mtrs.
Cable Solutions specialise in the custom design and manufacture of customer specified harsh environment, underwater and composite cables.
With years of experience supplying cable into the subsea and marine sectors, Cable Solutions has gained unrivalled experience and a unique portfolio of bespoke cable designs through its in house design department. All cables are designed using flexible specification wire and materials making Cable Solutions subsea cable perfect for harsh environment dynamic applications.
Cable Solutions Worldwide LtdCraigearn Business ParkMorrison Way, KintoreAberdeenshire, AB51 0TH
e [email protected] 1467 633790 (tel)44 1467 631284 (fax)1st4cables.com
ROV & tether cables
Armoured & strain bearing cable
Subsea umbilicals
Towed array
Diver comms cable
Fibre optic
Oceanographic / harsh environment / underwater
Subsea lighting & camera cable
Offshore to shore power and data
Low MOQ’s
HS-SK 915 HS-SK 725
HS-SK 814
HS-SK 013.A HS-SK 880
HS-SK 807