the natural choice for part l compliance. - pilkington · changes to building regulations part l...

12
Changes to Building Regulations Part L 2010 “Pilkington solutions” The natural choice for Part L compliance.

Upload: ngophuc

Post on 01-Dec-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

ChangestoBuildingRegulationsPartL2010

“Pilkingtonsolutions”

ThenaturalchoiceforPartLcompliance.

Contents

1. PartL(England&Wales)2010

– Introduction

– Headlinechanges

– Windowsinnewhomes

– Replacementwindows inhomes

– Conservatories

– Newnon-domestic buildings

– Existingnon-domestic buildings

2. Section6 (Scotland)2010

3. Summary

4. Actions

Par

t L (E

ngla

nd &

Wal

es) 2

010

1. PartL(England&Wales)2010

Introduction

• TheGovernmenthasannouncedaplantosteadilyimprovetheenergy

efficiencyofbuildings

• Significantchangesforwindowsin2010

• ResponsestopublicconsultationweresubmittedinSeptember2009

• FinalApprovedDocumentswerepublishedon30thApril2010with

implementation1stOctober2010

• Themainchangesandconsequencesforyourbusinessandyour

customers,areoutlinedintherelevantsections

Headlinechanges

• Allnewbuildingshavetargetof25%reductioninCarbonDioxide

(CO2)emissionsover2006level

• WindowEnergyRatings(WERs)willbecomethemaincompliancefor

replacementwindowsinhomes

– AlternativerouteretainedforwindowU-values

• NochangeforConservatories

• IncreasedfocusonlimitingsolargaininSummer

(reducingloadonair-conditioningorneedtoinstallairconditioning)

• Focusonsolarcontrolemphasizedparticularlyforpublicand

commercialbuildings

Windowsinnewhomes

• Targetof25%reductioninCO2emissionsover2006level

• TotalisbasedonoverallbuildingefficiencythroughSAPcalculation

– therightglasschoicewillinfluencethis

• Nospecificrequirementforwindows(otherthan“backstop”ofwindowU-value

=2.0W/m2K)–PilkingtonK Glass™andPilkingtonenergiKare™exceedrequirements

• TheoptimumcombinationofwindowgandU-valueswillgivethebestresultinSAP

– i.e.simplyloweringtheU-valuemayresultinworseoverallperformance

– Solargain(gvalue)asimportantaconsideration

• HouseBuilderscoulduseenergyefficientwindowstooffsetotherbuildingcosts

• UsingPilkingtonK Glass™especiallycombinedwithPilkingtonOptiwhite™asin

PilkingtonenergiKare™offerstheidealsolution

– PilkingtonenergiKare™Triplewillprovidetheultimateinenergyefficiencyfor

forwardlookinghousebuildersandforlowandzerocarbonsolutions

Replacementwindowsinhomes

• WindowEnergyRating(WER)bandCtobeminimumrequirementforallwindows

androoflights.Alternativeroute–maximumwindowU-valueof1.6W/m2K

– WERratingsaretheeasywaytodemonstratecomplianceinawaywhichcanbe

understoodbyhouseholders.Pilkingtonhasarrangementsinplacetohelp

windowcompaniesthroughtheapprovalsprocess.

• PilkingtonenergiKare™cost-effective,simplesolutionwithCratingforcompliance

andBorAfordifferentiation

• Wherenecessarytoretaincharacterofbuilding,centrepaneU-valueof1.2W/m2K

forreplacementwindowsorsupplementsingleglazingwithlow-esecondaryglazing

– PilkingtonK Glass™isidealproductforlatter

• GlazeddoorsmusthaveamaximumU-valueof1.8W/m2K

– easilyachievedusingPilkingtonK Glass™andPilkingtonenergiKare™

• WindowEnergyRatingscanbeusedforotherdomestic-likebuildings,

e.g.StudentaccommodationandCareHomes

Conservatories

• Small,domesticconservatories(<30m2)willnotbeintroducedintoPartLforthe

firsttime(asoriginallysuggestedintheconsultation)

• IGUswithoutlow-eglasscanstillbeused

– PilkingtonK Glass™andPilkingtonActiv™stilldeliverenergysavingandcomfort

benefitstoconsumerandallowyearrounduseofconservatory

• Exemptiononlyappliesif;

– Thermallyseparatedfromhouse,and

– Heatingsystemofdwellingnotextendedintoconservatory

• Wheretheseconditionsnotmet,glazingneedstobetosamestandardasfor

replacementwindows

• Despitethissetback,progressiveimprovementsinenergyefficiencyofconservatories

stillexpectedin2013and2016

– Totalenergyperformancemaybeintroducedforconservatories

New

Win

dow

s, R

epla

cem

ents

& C

onse

rvat

orie

s

Newnon-domesticbuildings

• Target25%(aggregate)reductioninCO2emissionsacrossallnewnon-domestic

buildings(includinghotels)comparedwith2006

• CompliancedemonstratedonthebasisoftotalCO2emissionsusingthe

GovernmentapprovedsoftwareSBEM

– therightglasschoicewillinfluencethis

• Notighteningoftherequirementsonwindowsspecifically

– limitingvaluesforglazedelementsleftunchangedi.e.windowU-value2.2W/m2K

• Nolimitingvalueondisplaywindowssuchasshopwindows,carshowroomsand

similarglazing–singleglazingcanstillbeused

• SBEMtakesintoaccountheatloss,solargainanddaylighttransmission–recognising

thatloweringU-valuenotalwaysthebestwaytoimproveenergyefficiency

• Limitingvaluemeansthatnonlow-emissivityglasswillnotbeallowed

• Exactglazingcombinationwilldependontypeofbuildingandwhetherair-conditioned

ornaturallyventilated

• PilkingtonK Glass™canmeetthelimitingvaluewithoutgasfillandtheremaybe

opportunitiestoinclude:

– solarcontrolglasssuchasPilkingtonEclipse Advantage™orPilkingtonSuncool™

Non

-dom

esti

c

Existingnon-domesticbuildings

• MaximumU-valueforwholeunit(i.e.frame+glass)is1.8W/m2K

• Wherenecessarytoretaincharacterofbuilding,centrepaneU-valueof1.2W/m2Kfor

replacementwindowsorsupplementsingleglazingwithlow-esecondaryglazing

– PilkingtonK Glass™isidealproductforlatter

• If buildingsessentiallydomestic(e.g.studentaccommodation,carehomes,etc.)same

requirementsasfordomesticbuildings,i.e.WERbandC,soPilkingtonenergiKare™isideal.

• Doorswith>50%glazedareamustbeamaximumof1.8W/m2K,therefore

PilkingtonK Glass™withargongasand/orwarmedgespacercancomply

• Replacementcurtainwallingrequirement:OverallU-valuedependentupon

glazedproportionand%openinglights

• PilkingtonK Glass™canbeusedinnon-domesticreplacementwindows

• Combinedwithincreasedemphasisonsolarcontrolinthesetypesofbuildings,

productssuchasPilkingtonOptitherm™,PilkingtonSuncool™,

PilkingtonEclipse Advantage™,PilkingtonSolar-E™andPilkingtonActiv™Neutral

shouldbeconsidered(dependingonperformancelevelrequired)

Sec

tion

6 (S

cotl

and)

201

0

Replacementwindowsinhomes(cont)

• Exemptionforlistedbuildingsandthoseinconservationareasismore

clearlydefined

– PilkingtonenergiKare™Legacyistheidealsolutionwheredesignis

constrained(orutilizePilkingtonK Glass™inappropriateframes)

2. Section6(Scotland)2010

What’sdifferentabouttheScotlandRegulations?

• Structure,timingandimplicationsverysimilartoEnglandandWales

• Newhomes:30%CO2improvementrequired.PilkingtonenergiKare™

remainstheidealcosteffectivesolution.Forsmallerbuildersthat

requireawindowU-valueof1.5,PilkingtonOptitherm™providesan

alternativesolution

• Existinghomes:WERbandCrequiredasminimum.

PilkingtonenergiKare™Plusenableswindowstoeasilycomply

• Extensionstohomes:Poorfabricinexistinghome-WERbandA

orUw=1.6requiredasminimum.PilkingtonenergiKare™Plus

isanoption.Otherwise-WERbandCrequiredasminimum.

PilkingtonenergiKare™Plusenableswindowstoeasilycomplyif you

raisethestandardoftheremainderofthebuilding

• Conservatories:2.0W/m2KwindowU-valuerequiredinallglazing–

easilyachievableusingPilkingtonK Glass™

• Newnon-domesticbuildings:target30%CO2improvementrequired

– PilkingtonK Glass™remainsideallow-esolutionfor

thermalinsulation

– PilkingtonEclipse Advantage™, PilkingtonSolar-E™and

PilkingtonActiv™Neutralofferwidechoicetosuitallapplications

• Existingnon-domesticbuildings:WithwindowU-valuesat1.6W/m2K

itprovidesanopportunitytousePilkingtonenergiKare™Plus

3. Summary

• Sweepingchangesinlinewithgovernmentplanstoimproveenergyefficiencyof

allbuildings

• Furtherchangesplannedfor2013andbeyond

• Glazinghasapivotalroleinmeetingthechallenges

• ProductsfromthePilkingtonrangearesuitedtomeetallfuturerequirements

• PilkingtonK Glass™andPilkingtonenergiKare™rangeareidealinthemajority

ofapplications

• SolarcontrolproductssuchasPilkingtonActiv™Blue,PilkingtonSuncool™range,

PilkingtonEclipse Advantage™andPilkingtonSolar-E™ areincreasinglyimportant

assolutionsforenergyefficientglazing

Foradditionaldetailsonthechanges

pleaserefertoourlatestupdates:

‘Bulletin10forEnglandandWales’and

‘Bulletin11forScotland’

Todownload,visit

www.pilkington.co.uk/buildingregulations

Forfurtherinformationpleasecontact

yourusualPilkingtonsalescontact,email

[email protected]

customercontactcentreon01744692000.

Bulletin 11Building (Scotland) Amendments Regulations 2010Changes to Technical Handbooks - Section 6 (Energy) 2010June 2010

IntroductionOn 6th April 2010, the Scottish Government

released the new versions of the domestic and

non-domestic Technical Handbooks in support of

the Building (Scotland) Amendments Regulations

2010. They will come into effect on 1st October

2010. The amendments have been made against

the background of the Sullivan report, which

outlined a low carbon building standards strategy

for Scotland. It recommended improvements in

energy efficiency in 2010 and 2013 with a target

of zero carbon new buildings by 2016 or 2017.

This Bulletin summarises the parts of the new

Technical Handbooks that are directly relevant

to the energy performance of glazing.

Headlines

• Significant reductions in target carbon dioxide

(CO2) emissions for all new buildings (compared

with 2007)

• Requirements for Window Energy Ratings

and window U-values have been tightened for

replacement windows for dwellings

• Severe restrictions are placed on the use of centre

pane U-values

• More conservatories fall in the scope for low

emissivity (low-e) glass

• Higher standards for windows for extensions

where the fabric of the existing dwelling is poor

• Increased focus on limiting solar gains during the

summer, in non-dwellings

New dwellings

The CO2 emissions associated with the energy

consumption of the whole dwelling remains as

the sole criterion for demonstrating compliance,

in that the predicted rate of emissions from the

dwelling (the Dwellings Emission Rate) must not

be greater than the Target Emissions Rate (based

on a notional dwelling). The standard government

software, SAP, provides the means for determining

compliance. For 2010, an aggregate target 30%

reduction in CO2 emissions (compared with the

2007 standard) has been set.

However, this does not mean every component

of a building will have to improve by 30%. As for

2007, there are no specific elemental requirements

for windows other than ‘long stops’. The long

stop, or limiting value, for the U-value for

windows, doors and rooflights has been set at

1.8 W/m2K. No restrictions have been placed on

glazed areas, offering the designer flexibility to take

advantage of energy saving glass. As an alternative,

particularly aimed at the self-build sector, the

dwelling can be designed to the same elemental

values as for the notional dwelling and effectively

considered ‘deemed-to-satisfy’. In the notional

dwelling, a window U-value of 1.5 W/m2K and

4.4m2 of solar thermal panels have been assumed.

In summary The Scottish Government has released the new versions of the domestic and non-domestic Technical Handbooks in support of the Building (Scotland) Amendments Regulations 2010, coming into force on 1st October 2010. New buildings will have to be at least 30% more efficient than current new buildings.

For replacement windows, the requirements for Window Energy Ratings and window U-values have been tightened. Severe restrictions are placed on the centre pane U-value compliance route. The benefit of supplementing existing single glazing with secondary glazing has also been recognised. Energy efficient glazing such as Pilkington K Glass™ and Pilkington energiKare™ are well placed to satisfy these requirements.

For non-dwellings, there is a greater focus on limiting solar gains in the summer, increasing opportunities for high performance solar control glass such as Pilkington Suncool™, Pilkington Eclipse Advantage™ and Pilkington Solar-E™. This Bulletin summarises the changes which are relevant to glazing. They come into force on 1st October 2010.

BulletinBulletin 11Building (Scotland) Amendments Regulations Building (Scotland) Amendments Regulations Changes to Technical Handbooks - Section 6 (Energy) Changes to Technical Handbooks - Section 6 (Energy) June June 22001100

IntroductionIntroductionOn 6th April 2010, the Scottish Government

released the new versions of the domestic and

non-domestic Technical Handbooks in support of

the Building (Scotland) Amendments Regulations

2010. They will come into effect on 1st October

2010. The amendments have been made against

the background of the Sullivan report, which

outlined a low carbon building standards strategy

for Scotland. It recommended improvements in

energy efficiency in 2010 and 2013 with a target

of zero carbon new buildings by 2016 or 2017.

This Bulletin summarises the parts of the new

Technical Handbooks that are directly relevant

to the energy performance of glazing.

HeadlinesHeadlines

•• Significant reductions in target carbon dioxide

(CO2) emissions for all new buildings (compared

with 2007)

•• Requirements for Window Energy Ratings

and window U-values have been tightened for

replacement windows for dwellings

•• Severe restrictions are placed on the use of centre

pane U-values

•• More conservatories fall in the scope for low

emissivity (low-e) glass

•• Higher standards for windows for extensions

where the fabric of the existing dwelling is poor

•• Increased focus on limiting solar gains during the

summer, in non-dwellings

In summaryThe Scottish Government The Scottish Government has released the new has released the new versions of the domestic versions of the domestic and non-domestic and non-domestic Technical Handbooks in Technical Handbooks in support of the Building support of the Building (Scotland) Amendments (Scotland) Amendments Regulations 20Regulations 20110, coming 0, coming into force on into force on 11st October st October 2020110. New buildings will 0. New buildings will have to be at least 30% have to be at least 30% more efficient than more efficient than current new buildings.current new buildings.

For replacement windows,the requirements for Window Energy Ratings and window U-values have been tightened.Severe restrictions are placed on the centre pane U-value compliance route. The benefit of supplementing existing single glazing with secondary glazing has alsobeen recognised. Energy efficient glazing such as Pilkington K Glass™ and Pilkington energiKare™

are well placed to satisfy these requirements.

For non-dwellings, For non-dwellings, there is a greater focus there is a greater focus on limiting solar gains on limiting solar gains in the summer, in the summer, increasing opportunities increasing opportunities for high performance for high performance solar control glass such solar control glass such as Pilkington as Pilkington SuncoolSuncool™™, , Pilkington Pilkington Eclipse Eclipse AdvantageAdvantage™™ and and ™™ and ™™

Pilkington Pilkington Solar-ESolar-E™™..This Bulletin summarises This Bulletin summarises the changes which are the changes which are relevant to glazing. relevant to glazing. They come into force They come into force on on 11st October 2st October 200110.0.

Bulletin 10Changes to Building Regulations Part L (England & Wales) 2010June 2010

IntroductionThe new Approved Documents for Part L of the

Building Regulations in England and Wales were

published by the Government’s Department for

Communities and Local Government (CLG) on

30th April 2010. They will come into effect on

1st October 2010. The previous amendments to

Part L in 2006 introduced very few significant

changes for products from the fenestration

industry. This was in recognition of the major

steps the industry had taken to develop energy

efficient products in time for the 2002 changes.

However, the expectation was that significant

improvements would be required from the

industry for 2010. This Bulletin summarises the

parts of the new Approved Documents that are

directly relevant to glazing.

Headlines

• Significant reductions in target carbon dioxide

(CO2) emissions for all new buildings (compared

with 2006)

• Requirements for Window Energy Ratings

and window U-values have been tightened for

replacement windows for dwellings

• Greater restrictions are placed on the use of

centre pane U-values

• Recognition of benefits of supplementing

existing single glazing with low-emissivity (low-e)

secondary glazing

• Increased focus on the risk of overheating in

summer, particularly in non-dwellings

New dwellings

The CO2 emissions associated with the energy

consumption of the whole dwelling remains as

the sole criterion for demonstrating compliance,

in that the predicted rate of emissions from the

dwelling (the Dwelling Emissions Rate) must not

be greater than the Target Emissions Rate (based

on a notional dwelling). The standard government

software, SAP, provides the means for determining

compliance, although it has been revised to reflect

the change.

For 2010, a target 25% reduction in CO2 emissions

(compared with 2006) has been set, following the

well-documented roadmap that was described in

our Bulletin 8 (issued August 2008).

However, this does not mean every component of a

building will have to improve by 25%. As for 2006,

there are no specific elemental requirements for

windows other than ‘long stops’. The long stop, or

limiting value, for the U-value for windows, roof

windows, glazed rooflights, pedestrian doors etc.,

has been set at 2.0 W/m2K. There is a cautionary

note about designing dwellings where the glazing

total area is less than 20% of the floor area leading

to a need for more artificial lighting and an

associated increase in energy consumption.

In summary The Part L Approved Documents of the Building Regulations for England and Wales have been issued, coming into force on 1st October 2010.

New buildings will have to be at least 25% more efficient than current new buildings.

For replacement windows, the requirements for Window Energy Ratings and window U-values have been tightened. Greater restrictions are placed on the centre pane U-value compliance route. The benefit of supplementing existing single glazing with low-e secondary glazing has also been recognised. Energy efficient glazing such as Pilkington K Glass™ and Pilkington energiKare™ are well placed to satisfy these requirements.

For non-dwellings, there will be a greater focus on limiting solar gains in the summer, increasing opportunities for high performance solar control glass such as Pilkington Suncool™, Pilkington Eclipse Advantage™ and Pilkington Solar-E™.

This Bulletin summarises the changes which are relevant to glazing. They come into force on 1st October 2010.

4. ActionPlanning

• FordomesticwindowstocomplyviatheWindowEnergyRatingsroute,youwillneed

toberegisteredwithBFRCoranotherapprovedschemebeforeOctober2010

• Don’tleaveittoolate

– Checkthatyourcustomersunderstandandarereadyforthechangestoo

• AssistancethroughtheWindowEnergyRatingsapprovalprocessfor

Pilkingtoncustomers

– Forfurtherdetailscallourcustomercontactcentreon01744692000

• Thinkaboutwhichproductsyouwilluseforcomplianceorimprovedenergy

performanceinallbuildingtypes:

– Conservatories–PilkingtonK Glass™andPilkingtonActiv™

– Nondomestic–PilkingtonK Glass™andPilkingtonSolarControlrange

– Newhomes–PilkingtonenergiKare™

– Existinghomes–PilkingtonenergiKare™

Sum

mar

y &

Act

ion

Pla

nnin

g

ACT NOW

Warning!Review glazingsolution for Part L DEADLINE

January April

FinalBuildingRegulationspublished

Ensuremeansofcomplianceinplacefordomesticwindowsupplyroute

NewBuildingRegulationsimplemented

July October

ActivTM

self-cleaning glass

Pilkington

G la s s

Pilkington Building Products - UKPrescotRoad,StHelens,WA103TTUnitedKingdom

[email protected]

www.pilkington.co.uk 9041-July2010

Tothefullestextentpermittedbyapplicablelaws,NipponSheetGlassCo.Ltd.anditssubsidiarycompaniesdisclaimallliabilityforanyerrorinoromission

fromthispublicationandforallconsequencesofrelyingonit.