Accelerated Vaporization Rate The New Most Powerful Solution for Accelerated Vaporization 120W High Power Supreme Energy Utilization The Lumenis Pulse™ 120H holmium laser system and the innovative Xpeeda™ D/S/L fiber, form an amazing combination of power & efficiency for minimized vaporization procedure time.

Upload: haxuyen

Post on 30-Aug-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Accelerated Vaporization Rate

The New Most Powerful Solution for Accelerated Vaporization

120W High Power

SupremeEnergy Utilization

The Lumenis Pulse™ 120H holmium laser system and the innovative Xpeeda™ D/S/L fiber, form an amazing combination of power & efficiency for minimized vaporization procedure time.

56% 56%

37%

19%

9%

3% 1% 1%

0.75 1 1.5 2 2.5 3 3.5 4 mm

Ener

gy (%

)

Percent of Energy Delivered to Target Tissue vs. Fiber Distance from Tissue (mm)

Lumenis Pulse 120H Superior Laser Urology Platform

Improved vaporization rate: Delivers 120W - the highest holmium power on the market. Superior power generates accelerated vaporization rate.

Improved safety: Pulse reshaping technology, powered by a dedicated footswitch offers enhanced hemostasis.

Improved vision: Delivers 80Hz - the highest holmium repetition rate on the market. Designed for improved vision and smoother ablated area during a procedure.

Minimized fiber-tissue distance allows better energy utilization

Xpeeda Fiber Supreme Energy Utilization

“For Vaporization of the prostate, the Lumenis Pulse™ 120H stands apart from other available technologies and is clearly superior to KTP (GreenLight®* Laser) or TURP’s. Bleeding is minimal, tissue is easier to remove and, as we have experienced, patients can have their catheter removed almost immediately and go home the same day.”Mr. Christof Kastner, M.D., Consultant Urologist, Cambridge University NHS Trust, UK

Better energy utilization: The new Xpeeda side-firing fiber revolutionizes utilization of the holmium power by delivering more energy directly to the tissue, due to the ability to use it in contact with the tissue during the entire procedure.

Easier to use: Vaporization rate can be adjusted through the ability to control the distance of the fiber from the tissue, without having to change the system’s settings.

More durability: The improved durability and innovative design allow the fiber to withstand the high power laser emission of the Lumenis Pulse120H and last the entire procedure.

* GreenLight is a registered trademark of Laserscope Corporation© 2014 All Rights Reserved. The Lumenis Group of Companies. PB-1005553 Rev AS U R G I CA L . lu m eni s .c o m

AMERICAS

San Jose, CA, USAT +1 408 764 3000 +1 877 586 3647F +1 408 764 3999

EMEA

Dreieich Dreieichenhain, GermanyT +49 6103 8335 0 F +49 6103 8335 300Roma (RM), ItalyT +39 06 90 75 230 F +39 06 90 75 269Hertfordshire, UKT +44 20 8736 4110 F +44 20 8736 4119

JAPAN

Tokyo, JapanT +81 3 4431 8300F +81 3 4431 8301

ASIA / PACIFIC

Beijing, ChinaT + 86 10 5737 6677Gurgaon, IndiaT + 91 124 422 07 95Kowloon, Hong KongT + 852 217 428 00 F + 852 272 251 51

Xpeeda Fiber Specifications

Delivery Device Ho:YAG Nd:YAGCompatible wavelength

Total length 310 cm (Fiber length tolerance: ± 20 cm)

Maximum output power 120W 100W

Maximum output energy 2 Joules

Fiber core diameter 550 μm

Maximum output diameter 2.5mm

Minimum working channel diameter 7.5fr

Number of uses Single-use

Sterilization Supplied EtO-sterilized

Components Laser connector, glass fiber, metal cap with line guides, adjustable handle and rigid tubing.

Laser systems compatibility Lumenis Pulse 120H, VersaPulse® PowerSuite™, VesaPulse PowerSuite Dual Wavelength, VersaPulse P20

The Xpeeda D/S/L fiber is intended for use with compatible lasers in surgical procedures involving open, laparoscopic, endoscopic ablation, vaporization, excision, incision and coagulation of soft tissue.

Lumenis Pulse 120H Specifications

Parameter Value Wavelength 2.1 um

Max Optical Power 120 W

Repetition Rate 5-80 Hz

Pulse Energy 0.2-6 J

Aiming Beam Green. 3 intensity settings and blinking mode

Pulse Width Adjustable

Smart Identification System (SIS) YES

Voice confirmation indicating system’s operational status YES

Dual Pedal Footswitch YES

Fiber & Suction Tube Support Arm YES

Integrated Suction Pump YES

Dimensions [W / L / H] 47 x 116 x 105 cm / 18.5’’ x 45.6’’ x 41.3’’

Weight 245 kg / 539 lbs for single phase

Electrical 200-240 VAC, <46 Amp*, 50/60 Hz

Delivery systems Lumenis SIS reusable and single use delivery systems

Warranty One year parts and labor

LASER CLASS 4 / IVHolmium:YAG Laser: 2.1μm, 6J max, 1300μs pulse max

LASER CLASS 3R / IllaDPSS Laser: 532nm, 5mW max, CW

VISIBLE AND INVISIBLE LASER RADIATIONAVOID EYE OR SKIN EXPOSURE TO DIRECTOR SCATTERED RADIATIONCLASS 4 LASER PRODUCT per IEC 60825-1: 2007CLASS IV LASER PRODUCT per 21 CFR 1040.10 AND 1040.11

LB -

1003

2650

_B