the straumann bone level implant - toledo perio
TRANSCRIPT
Respecting the biological distance
horizontal offset of the biological distance to help keep the microgapaway from the bone
Optimal position of smooth and rough surface
maximize osseointegration and crestal bone preservation with the SLActiveTM surface to the top
THE STraumann® BonE LEvEL ImpLanT gives you full treatment confidence, designed to preserve crestal bone through the unique Bone Control DesignTM, provides excellent esthetic outcomes through Consistent Emergence ProfilesTM, and simplifies handling with the CrossFitTM Connection.
The Straumann® Bone Level Implant offers you the following benefits:
ß High confidence and treatment predictability thanks to SLActiveTM – the surface with success built in.TM
ß Minimal tissue trauma from start to finish, providing superb esthetic results
ß Same procedures and instruments for all Straumann dental implants
EXCELLEnT ESTHETIC ouTComESTHROUGH CONSISTENT EMERGENCE PROFILESTM
SupErB CrESTaL BonE prESErvaTIonTHROUGH BONE CONTROL DESIGNTM
Microgap control
conical connection designed to provide bacterial seal and minimize sensitivity to lateral forces
Implant surface osseoconductivity
increased treatment predictability and confidence with SLActiveTM surface*
Biomechanical implant design
excellent fatigue strength and optimized force transmission
Straumann developed Bone Control DesignTM based on five fundamental biological principles to maximize crestal bone preservation and soft tissue stability.
* as compared to SLA®
Bone Control DesignTM
Designed to optimize crestal bone preservation by adherence to biological principles
Consistent Emergence ProfilesTM
Experience simplifed soft tissue management from start to finish
CrossFitTM Connection
Feel the fit of the self-guiding connection
"The tissue is the issue but the bone sets the tone."
5
– Dr. D. Garber
EXCELLEnT ESTHETIC ouTComESTHROUGH CONSISTENT EMERGENCE PROFILESTM
The consistent emergence profiles of Straumann’s prosthetic components are designed to facilitate highly esthetic restorations that mimic natural teeth. These components, designed to match the abutment profiles, allow you to easily attain esthetic results through soft tissue management, allowing for:
ß Minimal tissue trauma from start to finish
ß Simplified soft-tissue management
ß Enhanced patient comfort through
minimized soft tissue impingement
Courtesy of Dr. Barry P. Levin, Elkins Park, PA (surgical), Dr. Brian L. Wilk (restorative)
"The Straumann® Bone Level Implant provides treatment flexibility for patients with thin, scalloped, biotype soft tissue."
TemporaryAbutment
Polymer/Ti
AnatomicAbutment
Ti
Gold Abutment for crown
Au
Gold Abutmentfor bridge
Au
CementableAbutment
Ti
Straumann® CAD/CAM
ZrO2
Straumann® CAD/CAM
Ti
Prosthetic Options for Straumann® Bone Level Implant
† pending FDA clearance
Healing Temporary restoration Final restoration
"The implant procedure is technically no different than what I have been doing except for the new profile drill prep."
LOCATOR® Abutment
Ti
†
– Dr. Barry P. Levin, Elkins Park, PA
EXCELLEnT ESTHETIC ouTComESTHROUGH CONSISTENT EMERGENCE PROFILESTM
Feel the fit of the self-guiding connection
The prosthetic connection is intuitive, self-guiding and easy to grasp. The CrossFit™ connection:
ß Gives prosthetic flexibility and stability through its deep conical connection
ß Provides a clear-cut insertion through the guidance of 4 grooves
ß Designed to prevent rotation
conical connection(15˚)
4 grooves
SamE For aLL STraumann® DEnTaL ImpLanTS
SURGICAL KIT,
PROSTHETIC KIT,
PROCEDURE,
and INSTRUMENTS
"The implant procedure is technically no different than what I have been doing except for the new profile drill prep."
SImpLIFIED HanDLInGTHROUGH CrossFitTM CONNECTION
– Dr. William F. Runyan, Fort Worth, TX
0 1 2 3 4 5 6 7 8
Primarystability
(old bone) Secondarystability
(new bone)
Stabilitydip
Time (weeks)
S. R
agha
vend
ra, M
. Woo
d, T
.D. T
aylo
r (20
05)
Total stability
Stab
ility
SLA®
Stab
ility
0 1 2 3 4 5 6 7 8
Primarystability
(old bone)
Time (weeks)
Total stability
SLActiveTM
Secondarystability
(new bone)
SLA
ctiv
eTM (b
lue
line)
, SLA
® (d
otte
d bl
ue li
ne)
SLA®
Straumann's SLActiveTM surface sets a new standard in implant dentistry. As the first chemically active implant surface, SLActiveTM offers you:
ß Faster osseointegration to enhance confidence*
ß Increased treatment predictability*
ß Reduced healing times, from 6–8 weeks to 3–4 weeks*
ouTSTanDInG SuCCESS raTES SLActiveTM – THE SURFACE WITH SUCCESS BUILT IN.TM
The speed of osseointegration dictates the severity and duration of the stability dip.
SLActiveTM provides more predictability by achieving secondary stability sooner than SLA®.
Secondary Stability Sooner*
+ Clinical studies are ongoing.
* as compared to SLA®
"The results show that the SLActive™ surface is conducive to faster bone healing.*"
Topic Content Study Setup, Principal Investigator
prop
erty
test
s
Biomechanical stability
Ideal strength and fatigue strength of the Straumann® Bone Level Implant in comparison to competitors
Hydropulser tests, ISO 14801,M. Wieland, Switzerland
Reliability Measurement of tight screw fit after cyclic mechanical load of the Straumann® Bone Level Implant
Hydropulser tests, ISO 14801,M. Wieland, Switzerland
Microgap Measurements of gap size and tightness under static and dynamic load
Diverse test setups,M. de Wild, Switzerland
pre-
clin
ical
st
udie
s Bone maintenance
Bone maintenance with submerged and non-submerged implants placed at different heights
Delayed restoration, 60 implants, D. Cochran, USA
Interproximal bone maintenance with adjacently placed implants Immediate restoration, 72 implants, D. Tarnow, USA
clin
ical
stu
dies
Basic clinical evidence+
Performance and esthetic outcome in single tooth gaps in the anterior maxilla
Single center, 20 patients,D. Buser, Switzerland
Esthetics+ Submerged vs. non-submerged placement in the anterior maxilla and mandible
12 international centers, 134 patients, C. Hämmerle, Switzerland
A variety of indications+
Implant success and survival rate in daily dental practice More than 100 centers worldwide, More than 1250 implants
Straumann® Bone Level Implant – Study OverviewTo date, several studies have been initiated to substantiate the performance of the Straumann® Bone Level Implant.
– Dr. David L. Cochran, San Antonio, TX
Stra
uman
n pr
oduc
ts ar
e C
E m
arke
d
10/
07
USL
IT 2
29
International HeadquartersInstitut Straumann AG Peter Merian-Weg 12CH-4002 Basel, SwitzerlandPhone +41 (0)61 965 11 11Fax +41 (0)61 965 11 01
www.s t raumann.com
North American DistributorsStraumann USA, LLC 60 Minuteman Road Andover, MA 01810 Phone 800/448 8168 978/747 2500 Fax 978/747 2490 www.straumannusa.com
Straumann Canada Limited 4145 North Service Road, Suite 303Burlington, ON L7L 6A3 Phone 800/363 4024 905/319 2900 Fax 905/319 2911 www.straumann.ca
THE STRAUMANN® DENTAL IMPLANT SYSTEM –
Your CHoICE
ConFIDEnCE aT anY LEvEL
Straumann®
StandardStraumann®
Standard PlusStraumann®
Tapered EffectStraumann®
Bone Level
INTRODUCING ConFIDEnCE AT BonE LEvEL
Featuring
the unique
SLActive™ surface!