the telecardiology of 12-lead ecg
DESCRIPTION
The Telecardiology of 12-Lead ECG. Ray Hsieh Ph.D. 謝瑞建 Department of Information Management Yuan Ze University, Taiwan. The result of biology is from good engineering. -F. Starmer. Virtual Heart. Spiral Wave Simulation. Introduction. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/1.jpg)
Yuan-Ze University Department of Information Management
The Telecardiology of 12-Lead ECG
Ray Hsieh Ph.D. 謝瑞建Department of Information Management Yuan Ze University, Taiwan
![Page 2: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/2.jpg)
Yuan-Ze University - Department of Information Management
The result of biology is from good engineering.
-F. Starmer
![Page 3: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/3.jpg)
Yuan-Ze University - Department of Information Management
Virtual Heart
![Page 4: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/4.jpg)
Yuan-Ze University - Department of Information Management
Spiral Wave Simulation
![Page 5: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/5.jpg)
Yuan-Ze University - Department of Information Management
Introduction
Most hospitals use paper 12-lead ECG.
How to extract waveform data from clinically-used ECG instruments ?
How to integrate different ECG file formats ? (HP SCP-ECG & Philips XML-ECG)
![Page 6: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/6.jpg)
Yuan-Ze University - Department of Information Management
Paper-Based 12-lead ECG
![Page 7: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/7.jpg)
Yuan-Ze University - Department of Information Management
12-lead ECG Measurement
![Page 8: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/8.jpg)
Yuan-Ze University - Department of Information Management
Paper ECG
![Page 9: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/9.jpg)
Yuan-Ze University - Department of Information Management
Objectives
To enable the integration of heterogeneous and encrypted clinically-used 12-lead ECG file formats, such as HP SCP-ECG, Philips XML-ECG.
To develop a novel 12-lead ECG information management system for clinical applications.
![Page 10: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/10.jpg)
Yuan-Ze University - Department of Information Management
![Page 11: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/11.jpg)
Yuan-Ze University - Department of Information Management
System Construction
![Page 12: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/12.jpg)
Yuan-Ze University - Department of Information Management
Methods
SCP-ECG decode XML-ECG noise removal WEB-based and mobile-based ECG system and
DICOM-ECG Conversion Integration with HIS and PACS
![Page 13: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/13.jpg)
Yuan-Ze University - Department of Information Management
SCP-ECG Decoding
![Page 14: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/14.jpg)
Yuan-Ze University - Department of Information Management
![Page 15: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/15.jpg)
Yuan-Ze University - Department of Information Management
![Page 16: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/16.jpg)
Yuan-Ze University - Department of Information Management
Noise Removal by Stationary Wavelet Transform
)2()()( , ktdktatECG j
k jkj
kk
31
1ln26725.0
)( ,
jj
ffNdmedium
th kjj
![Page 17: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/17.jpg)
Yuan-Ze University - Department of Information Management
ECG processing
![Page 18: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/18.jpg)
Yuan-Ze University - Department of Information Management
Noise Removal of ECG
![Page 19: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/19.jpg)
Yuan-Ze University - Department of Information Management
Web-based ECG Information System
![Page 20: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/20.jpg)
Yuan-Ze University - Department of Information Management
Web-based ECG Information System
![Page 21: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/21.jpg)
Yuan-Ze University - Department of Information Management
12-lead ECG on iPod
![Page 22: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/22.jpg)
Yuan-Ze University - Department of Information Management
Mobile-based 12-Lead ECG Queries and Diagnoses
![Page 23: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/23.jpg)
Yuan-Ze University - Department of Information Management
Medical Informatics Standards
Digital Image and Communication in Medicine (DICOM)
Picture Archiving and Communication System (PACS).
Hospital Information System (HIS).
![Page 24: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/24.jpg)
Yuan-Ze University - Department of Information Management
HIS-PACS-DICOM-ECG
HIS
HISDatabase
Basic Worklist Service Provider
(Modality Worklist Server)
Storage Service Provider
(Image Server)PACS Viewer
ECG Console
ECG
PACS SystemClient ECG Module
![Page 25: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/25.jpg)
Yuan-Ze University - Department of Information Management
PACS ECG Scheduling Query
![Page 26: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/26.jpg)
Yuan-Ze University - Department of Information Management
PACS Viewer with Embedded Image and Waveform Interpreters
![Page 27: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/27.jpg)
Yuan-Ze University - Department of Information Management
Mobilized DICOM-ECG & Image Viewer
![Page 28: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/28.jpg)
Yuan-Ze University - Department of Information Management
Mobilized DICOM-ECG & Image Viewer
![Page 29: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/29.jpg)
Yuan-Ze University - Department of Information Management
![Page 30: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/30.jpg)
Yuan-Ze University - Department of Information Management
![Page 31: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/31.jpg)
Yuan-Ze University - Department of Information Management
Clinical Applications
![Page 32: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/32.jpg)
Yuan-Ze University - Department of Information Management
![Page 33: The Telecardiology of 12-Lead ECG](https://reader036.vdocuments.net/reader036/viewer/2022081502/56815a8d550346895dc80351/html5/thumbnails/33.jpg)
Yuan-Ze University - Department of Information Management
Discussions Clinical Applications
Mobile-based 12-lead ECG system can enhance the time efficiency in emergency medical treatments.
DICOM-ECG can enhance the interoperability of 12-lead ECG records.
Web-based 12-lead ECG can improve the readability and portability of clinical 12-lead ECG reports.
The developed Web and mobile 12-lead ECG system has been adopted by Taoyuan Armed Forces General Hospital-Taiwan since March, 2008.