the xevo tq-s micro - waters corporation...500 mrm/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5...

30
©2014 Waters Corporation 1 The Xevo ® TQ-S micro Redefining Compact Performance Sensitivity Beyond Expectation Gunnar Weibchen

Upload: others

Post on 05-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 1

The Xevo® TQ-S micro

Redefining Compact Performance

Sensitivity Beyond Expectation

Gunnar Weibchen

Page 2: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 2

The power of Xevo

Page 3: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 3

What is Xevo?

Xevo is Engineered Simplicity

Xevo is innovative information rich analysis

Xevo is versatility

Xevo systems are backed by providing the most complete system solutions backed by superior support

Xevo is robust, reliable, accessible high performance

Page 4: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 4

Class Leading Performance that can

Fit into any Lab

Xevo TQ MS footprint

Xevo TQ-S micro Compact design reduces lab footprint

Page 5: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 5

Sr ion guide

with high quality data

RADAR and PICs

Quantitative workflow updates – Standard Addition – Increased no. compounds

Xevo TQ-S micro Innovative Technologies

Page 6: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 6

Increasing Instrument Uptime

Key Analytical Challenges

Reducing Sample Turnaround Time

Easy Method Transfer

Understanding Sample Complexity

Page 7: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 7

Increasing Instrument Uptime

Page 8: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 8

Increasing Instrument Uptime: StepWave

Robust performance driven by proven Z-spray and StepWave technologies

Page 9: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 9

0

20000

40000

60000

80000

100000

120000

0 100 200 300 400 500 600 700 800 900

Pea

k A

rea

Injection number

Mean Peak area = 86,501 Standard Deviation = 2,961 %RSD = 3.42%

+15 % of mean

-15 % of mean

900 injections of verapamil in protein-precipitated plasma

Xevo TQ-S micro Robustness data

Page 10: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 10

Xevo TQ-S micro: Sensitivity improvement

UPLC/MRM data for the Xevo TQ-S micro relative to the Xevo TQD

ESI- Teflubenzuron, 379>339

Time10.40 10.60 10.80 11.00 11.20 11.40

%

0

100

10x peak area, 5x S:N

ESI+ Vitamin D3, 401>383

Time11.00 11.20 11.40 11.60 11.80 12.00 12.20 12.40 12.60 12.80

%

0

16x peak area, 4x S:N

Positive ion pesticides compounds 1 pg/µL - 10 pg on column

Time9.40 9.60 9.80 10.00 10.20 10.40 10.60 10.80 11.00 11.20 11.40 11.60 11.80 12.00

%

0

Raven_Positive ion pesticides_DDMW14MAY2014_003 Sm (Mn, 2x2) 20: MRM of 2 Channels ES+ 306.2 > 201.1 (Buprofezin

3.17e6

6x peak area, 5x S:N

ESI+ Buprofezin, 306>201

Page 11: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 11

Reducing Sample Turnaround Time

Page 12: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 12

Reducing Sample Turnaround Time: Xcelerated Ion Transfer™ (XIT)

The new Xcelerated Ion Transfer electronics, featuring SpaceWire technology, enable rapid data acquisition without performance loss

Increasing MRM acquisition speed but maintaining data quality

Page 13: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 13

Xevo TQ-S micro Data quality at high speed - Buprofezin

Dwell and Delay Time %RSD (of 10 acquisitions)

10ms 2.33

5ms 5.08

3ms 2.22

1ms 5.49

50 MRM/s

500 MRM/s

4.1% peak area loss

2.08 e5

2.77 e5

2.80 e5

3.31 e5

10048

10059

9672

9642

Page 14: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 14

8.5% peak area loss

Xevo TQ-S micro Data quality at high speed - Metaxuron

Dwell and Delay Time %RSD (of 10 acquisitions)

10ms 4.47

5ms 2.52

3ms 2.77

1ms 6.26

50 MRM/s

500 MRM/s

23185

22705

22527

21226 6.00 e5

4.50 e5

5.31 e5

5.77 e5

Page 15: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 15

Easy Method Transfer

Page 16: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 16

Easy Method Transfer: Xtended Dynamic Range™ (XDR)

Easier to transfer methods from other instruments with higher or lower sensitivities Accessible sensitivity Up to 6 orders of linear dynamic range Xtended Dynamic Range made possible by updated detector electronics

Page 17: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 17 Time

0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20

%

0

Lidocaine injections at 6 orders of dynamic range without detector saturation

6 orders of dynamic range: Lidocaine

1x, 1 ng

1x, 100 pg

10x, 10 pg

82x, 1pg

876x, 100 fg

10,000x, 10 fg

10,000x magnification, 1 fg

Page 18: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 18

Understanding Sample Complexity

Page 19: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 19

RADAR - Unique simultaneous acquisition of MRM and full scan data

See what you cannot see in MRM alone

Improve method

development

Detect

unexpected contaminants

Characterise background

matrix

Understanding Sample Complexity: RADAR

Page 20: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 20

RADAR – Method Development

Phospholipids

All endogenous material

A

B

Page 21: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 21

RADAR – Unexpected contaminants

Identify unexpected contaminants

Melamine has been used as an adulterant in baby milk formula

Page 22: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 22

Full scan TIC

MRM traces

XIC m/z 212

1

2 3

4

5

6

RADAR – Characterize background matrix

Page 23: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 23

PICs – Confidence in identification

Hydromorphone reference spectrum

Hydromorphone acquired PICs spectrum

Product Ion Confirmation scanning (PICs) enables the user to confidently identify a peak and quantify the amount present

Page 24: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 24

Benefits of the Xevo TQ family

Page 25: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 25

Informatics solutions

QUANPEDIA™

QCMonitor

Trendplot

Page 26: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 26

TargetLynx XS Standard Addition

Page 27: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 27

Universal Source platform

Chromatographic versatility

Compatibility across the board

ESI APCI ESCi™

APPI APCI

APGC ionKey/MS ASAP

UPC2

Nanoflow ESI

H-Class and I-Class M-Class

Page 28: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 28

Xevo TQ Portfolio

Xevo TQD

Xevo TQ-S

Rugged robust and proven

The next step in robust sensitivity

A step up to ultimate sensitivity

Xevo TQ-S micro

Page 29: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 29

Xevo TQ-S micro summary

Increasing Instrument Uptime – Robust but sensitive performance from ZSpray and StepWave

Reducing Sample Turnaround Time

– Fast MRM acquisition rates with high quality data from XIT

Easy Method Transfer – Wider dynamic range for maximum performance with XDR

Understanding Sample Complexity

– Use RADAR and PICs technology to combine scan data with quantitative MRM analysis

Page 30: The Xevo TQ-S micro - Waters Corporation...500 MRM/s 4.1% peak area loss 2.08 e5 2.77 e5 2.80 e5 3.31 e5 10048 10059 9672 9642 ©2014 Waters Corporation 14 8.5% peak area loss Xevo

©2014 Waters Corporation 30

Questions?