the young energy ensures more safety · about standard. standard is a brand of india’s leading...
TRANSCRIPT
Domestic Products Catalogue 2017
The young energy ensures more safety
CORPORATE OFFICE
ABOUT STANDARD
STANDARD is a brand of India’s leading FMEG company, Havells India Ltd., that
offers a wide range of highly differentiated Domestic & Industrial Switchgear
products and Domestic Cables. The brand has been serving the Indian
customers for over five decades and has built a formidable reputation with its
high quality products in domestic as well as international markets.
It offers products such as MCBs, RCCBs, Distribution Boards (DBs), MCCBs,
RCBOs Changeover Switches, Switch Disconnector Fuses (SDFs), HBC Fuses,
Modular Switches, Copper Flexible Cables etc. In 2014-15, STANDARD marked
its entry into consumer product category with the launch of premium range
of Fans. Today, STANDARD boasts of having a comprehensive range of ceiling,
table, wall-mounted, pedestal fans and domestic exhaust fans.
STANDARD has pan-India marketing and distribution network stretching over
42 branch offices, 1,200 authorized dealers and 10,000 strong retail outlets
across the country. The company also has a wide presence in International
markets including Middle East, South East Asian countries, Malaysia, Singapore,
South Africa, Kenya, Ghana, Nigeria.
It has established a well-equipped infrastructure with state of the art facilities in
terms of plant, machinery and testing. STANDARD products are manufactured
at most modern and technologically advanced plants of its parent, Havells
India, located in different parts of the country such as Haridwar, Baddi,
Sahibabad, Faridabad and Alwar. All STANDARD products are designed on the
lines of Indian & International specifications and tested by nationally accredited
laboratories CPRI/ERDA.
STANDARD’s R&D is ebbed in company’s DNA. The company has a very
strong R&D team that has driven innovation to continuously deliver world-
class products. Its R&D centers are equipped with supreme quality CAD/
CAM machines for its entire stage of design and development. The R&D
team continuously works to create innovative solutions and new products
of high reliability and safety catering to meet the ever-changing demands of
various segments of customers. All its products are incorporated with special
technology rated for 10% higher current carrying capacity and can withstand
high temperature rise even during the worst of overloading conditions. It offers
best in class safety features along with better performance during low voltage
conditions too. STANDARD’s entire product range offers high performance,
best design and superior features like energy savings, longer life and shock
proof to name a few.
With its mission to offer quality products, efficient customer service and
everlasting relationship with partners, STANDARD holds unbeatable advantages
like expertise in LT Switchgear since last four decades, technology leadership,
excellent brand perception, wide dealer network, excellent after sales service
and value for money to its customers.
4
HARIDWAR PLANT
CONTENTS
5
06
16
18
22
30
34
58
Miniature Circuit Breaker (MCB)
Switch Disconnector (Isolators)
MCB Changeover Switch
Residual Current Circuit Breaker (RCCB / ELCB)
Residual Current Circuit Breaker With Overload & Short Circuit Protection (RCBO)
Distribution Boards & Enclosures
Metal Clad Plug & Socket
6
MINIATURE CIRCUIT BREAKER
7
Electricity is an inseparable part of our daily lifestyle. In residential, commercial and industrial sectors there are myriad systems, equipments and sophisticated appliances that depend on electrical energy. Uncontrolled electrical power can be extremely dangerous. Overloads, crowded wiring, short-circuits and all kinds of interruptions in electric supply can lead to devastating losses, least of them being financial.We at STANDARD are proud to be known and respected all over the world for our range of superior quality electrical control and safety devices. Through these, we speak of our lasting concern for safety, economy and productivity for our customers.The latest product from STANDARD is 10kA MCB, an advanced Indian design of high performance, current limiting and switching, for control and protection of industrial, commercial & domestic electrical sub circuits. It meets the latest specification IS / IEC : 60898-1 of B & C Characteristics.The primary function of the MCB is to protect the installation such as cable & other components from damage, caused due to overload & short-circuit fault. Overload can result in heating effect on cable. Protection in this respect is assured by matching the cable rating to the current rating of MCB.Under short-circuit condition, mechanical damage can occur due to strong magnetic field caused by high current peaks and overheating use cables on account use "exclusive let through energy". The current limiting action use"MCB" ensures low value of both peak current "cut off" and minimum let through energy.
FEATURES & BENEFITS
• Design
• Latest&oneofthebestdesignedMCB
• Higherperformanceinasmallerpackage
• MCBsconformstothelatestStandardsIS/IEC:60898-1/2002
• TheseMCBsprovidereliableprotectiontocircuitsagainstoverload&short-circuit ideal for industrial, commercial & residential installations
CERTIFICATIONS
• ISI
• Higherbreakingcapacity
• Breakingcapacityof10kAforthecompleterangefrom6Ato63Ainsingle pole and multipole tested at CPRI
LARGER TERMINALS
Dual termination facility for incoming side and can take wire upto 25sq. mm cross section. Wire may be of copper or aluminum.
SHOCK PROOF
Offer IP 20 degree of protection. All live parts are out of human reach ensuring safety to user.
LONGER LIFE
Reduced electro magnetic stresses resulting in increased contact life.
FLEXIBILITY
Can be mounted easily in any of the regular Distribution Boards.
ENERGY SAVING
IS / IEC : 60898-1 have recognized the growing importance of limiting power loss in Switchgear devices and stipulated max. permissible power loss values per pole of MCB. MCB having power loss figures of 50% lower watts than IS requirement. Thus, 50% energy & cost saving by application.
8
MINIATURE CIRCUIT BREAKER
TIME CURRENT CHARACTERISTIC CURVESBased on the Tripping Characteristics, Standard MCBs are available in ‘B’, ‘C’ and ‘D*’ curve to suit different types of applications.
‘B’ Curve: for protection of electrical circuits with equipment that does not cause surge current (lighting and distribution circuits).
Short circuit release is set to (3 - 5) In
‘C’ Curve: for protection of electrical circuits with equipment that causes surge current (inductive loads and motor circuits).
Short circuit release is set to (5 - 10) In
‘D*’ Curve: for protection of electrical circuits which causes high inrush current, typically 12-15 times the thermal rated current (transformers, X-ray machines etc.)
Short circuit release is set to (10 - 20) In
CURRENT LIMITING DESIGNIn a current limiting breaker, the tripping & arc control mechanism is so designed that under short circuit conditions, the contacts are physically separated and the electrodynamic forces set up by fault current assist the extinction in less than half cycle.
The figure shows the current limiting effect of a circuit breaker. Fault Traces for Voltage & Current
0 = Point of fault initiation
tx = Contact opening time (i.e., creation of arc)
t1 = Current / Voltage peak (i.e., current limitation)
t2 = Time to total extinction of arc (i.e., complete shutdown of fault current)
CHARACTERISTIC CURVES
0.01
0.10
1.00
10.00
100.00
1000.00
10000.00
Tim
e (s
ec.)
2 3 5 10 20 30 100
1.13 1.45
1
Multiples of Rated Current (x In)
B C D
PROTECTION UNLIMITED
STANDARD MCBs protect against overload and short circuit.
OVERLOAD PROTECTIONIt is achieved by thermal operation of the bimetal strip which deflects when heated by the over current going through it, thereby tripping the operating mechanism and causing the contact to open.
THERMOSTATIC BI-METALIt is a composite material comprising of two metallic layers of different co-efficient of thermal expansion which are permanently bonded together by pressure welding.
SHORT CIRCUIT PROTECTIONIn short circuit, the high current in the range of kA energises the solenoid and a magnetic field is created. Due to this magnetic field the anchor is pulled down which pushes the plunger to strike the inner latch, causing instantaneous opening of the contacts.
Voltage across contactsduring opening of MCB
Time
MaximumProspectiveFaultCurrent
Cut-offCurrent
A
B
0 tX t1 t2
Cur
rent
Volta
ge
0
As per
Thermal Tripping Magnetic Tripping
No tripping Tripping Time Hold Trip Time
IS / IEC 60898-1Current Current Limits Current Current Limits
I1 I2 t I4 I5 t
B Curve1.13 x In >1h 3xIn >0.1s
1.45 x In <1h 5 x In <0.1s
C Curve1.13 x In >1h 5xIn >0.1s
1.45 x In <1h 10 x In <0.1s
D* Curve1.13 x In >1h 10xIn >0.1s
1.45 x In <1h 20 x In <0.1s
l3 = 2.55 x ln1 s < t < 60s for ln < 32A
1 s < t < 120s for ln > 32A
*D Curve MCBs are available on special request only
9
MCB
Standard Conformity IS / IEC 60898-1
Type/Series B C D***
Rated Current (In) A 6 - 40* 0.5 - 63* 0.5 - 63*
Rated Voltage (ac) (Ue) V 240/415
Rated Frequency (f) Hz 50
Nos. of Poles (Execution) SP, SPN, DP, TP, TPN, FP **
Rated Short Circuit kA 10 10 6 to 32 - 10kA
Breaking Capacity 40 to 63 - 4.5kA
Utilization Category Magnetic Release Setting
(3-5)In (5-10)In (10-20)In
Rated Insulation Voltage (Ui) V 690
Rated Impulse Voltage (Uimp) kV 4
Electrical / Mechanical Endurance Endurance (No. of operations)Less than < 32AMore than > 32A
20,00010,000
Ambient Temperature (oC) -5 to +45
Terminal Capacity (Max) sq.mm 25
Vibration 3
Shock 40 mm free fail
Protection Class IP - 20
Installation Position Vertical / Horizontal
Mounting Clip on DIn Rail (35 mm x 7.5 mm)
Case & Cover Moulded, flame retardant thermoplastic material.
MINIATURE CIRCUIT BREAKER
POWER LOSS DETAILS
Dimensions (in mm)
S. No.MCB Rating
(A)
STANDARD MCBs Power
Loss (W)
Max. Permissible Power Loss (W) As per
IS/IEC:60898
1 6 0.9 3.0
2 8 1.1 3.0
3 10 1.6 3.0
4 16 2.5 3.5
5 20 2.8 4.5
6 25 3.2 4.5
7 32 3.4 6.0
8 40 4.9 7.5
9 63 7.3 13
TECHNICAL INFORMATION
*Current Ratings - 0.5A, 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
***D* Type MCB are available on request
** SP Single Pole SPN Single Pole Neutral DP Double Pole TP Three Pole TPN Three Pole Neutral FP Four Pole
60
44
45
70.5
8436
1 POLE 1 POL E + NEUTRAL& 2 P OL E
3 POLE 3 P OL E + NEUTRAL& 4 POLE
17.7 35.4 53.1 70.8
10
CurrentRating (Amps.)
Cat No.B-Curve
Cat No. C-Curve
0.5 - DSMSCDPF0X5
1 - DSMSCDPF001
2 - DSMSCDPF002
2.5 - DSMSCDPF2X5
3 - DSMSCDPF003
5 - DSMSCDPF005
6 - DSMSCDPF006
10 - DSMSCDPF010
16 - DSMSCDPF016
20 - DSMSCDPF020
25 - DSMSCDPF025
32 - DSMSCDPF032
40 - DSMSCDPF040
50 - DSMSCDPF050
63 - DSMSCDPF063
MINIATURE CIRCUIT BREAKER
CurrentRating (Amps.)
Cat No.B-Curve
Cat No. C-Curve
0.5 - DSMSCSNF0X5
1 - DSMSCSNF001
2 - DSMSCSNF002
2.5 - DSMSCSNF2X5
3 - DSMSCSNF003
5 - DSMSCSNF005
6 - DSMSCSNF006
10 - DSMSCSNF010
16 - DSMSCSNF016
20 - DSMSCSNF020
25 - DSMSCSNF025
32 - DSMSCSNF032
40 - DSMSCSNF040
50 - DSMSCSNF050
63 - DSMSCSNF063
MCB SINGLE POLE NEUTRAL (SPN)
MCB DOUBLE POLE (DP)
MCB SINGLE POLE (SP)
CurrentRating (Amps.)
Cat No.B-Curve
Cat No. C-Curve
0.5 - DSMSCSPF0X5
1 - DSMSCSPF001
2 - DSMSCSPF002
2.5 - DSMSCSPF2X5
3 - DSMSCSPF003
5 - DSMSCSPF005
6 DSMSBSPF006 DSMSCSPF006
10 DSMSBSPF010 DSMSCSPF010
16 DSMSBSPF016 DSMSCSPF016
20 DSMSBSPF020 DSMSCSPF020
25 DSMSBSPF025 DSMSCSPF025
32 DSMSBSPF032 DSMSCSPF032
40 DSMSBSPF040 DSMSCSPF040
50 - DSMSCSPF050
63 - DSMSCSPF063
11
CurrentRating (Amps.)
Cat No.B-Curve
Cat No. C-Curve
0.5 - DSMSCFPF0X5
1 - DSMSCFPF001
2 - DSMSCFPF002
2.5 - DSMSCFPF2X5
3 - DSMSCFPF003
5 - DSMSCFPF005
6 - DSMSCFPF006
10 - DSMSCFPF010
16 - DSMSCFPF016
20 - DSMSCFPF020
25 - DSMSCFPF025
32 - DSMSCFPF032
40 - DSMSCFPF040
50 - DSMSCFPF050
63 - DSMSCFPF063
CurrentRating (Amps.)
Cat No.B-Curve
Cat No. C-Curve
0.5 - DSMSCTNF0X5
1 - DSMSCTNF001
2 - DSMSCTNF002
2.5 - DSMSCTNF2X5
3 - DSMSCTNF003
5 - DSMSCTNF005
6 - DSMSCTNF006
10 - DSMSCTNF010
16 - DSMSCTNF016
20 - DSMSCTNF020
25 - DSMSCTNF025
32 - DSMSCTNF032
40 - DSMSCTNF040
50 - DSMSCTNF050
63 - DSMSCTNF063
MCB TRIPLE POLE NEUTRAL (TPN)
MINIATURE CIRCUIT BREAKER
MCB FOUR POLE (FP)
MCB TRIPLE POLE (TP)
CurrentRating (Amps.)
Cat No.B-Curve
Cat No. C-Curve
0.5 - DSMSCTPF0X5
1 - DSMSCTPF001
2 - DSMSCTPF002
2.5 - DSMSCTPF2X5
3 - DSMSCTPF003
5 - DSMSCTPF005
6 - DSMSCTPF006
10 - DSMSCTPF010
16 - DSMSCTPF016
20 - DSMSCTPF020
25 - DSMSCTPF025
32 - DSMSCTPF032
40 - DSMSCTPF040
50 - DSMSCTPF050
63 - DSMSCTPF063
12
SHUNT TRIP COIL
• TotriptheCircuitBreakerthroughShuntTripCoil,70%to110%ofthe rated voltage is to be applied across D1 & D2
• TheShuntTripcoilisshorttimeratedandittripthebreakerinstanta-neously. (i.e., continuous duty not required)
SHUNT TRIP
AUXILLIARY CONTACT
MINIATURE CIRCUIT BREAKER
Outgoing D1 Coil Terminal
D2 Coil TerminalIncoming
1 3
2 4
Shunt trip Connection Diagram
Incoming Connection
ACCESSORIES
Standard Conformity IS / IEC : 60947-3
Type/Series
Coil Consumption VA 6
Rated Voltage (ac) (Ue) V 240V
Rated Voltage (dc) (Ue) V 48, 24 & 12
Rated Frequency (f) Hz 50
Rated Insulation Voltage (Ui) V 690
Operating Voltage range V 70% - 110% of rated voltage
Electrical Endurance (Nos.) 10000
Ambient Temperature (oC) -5 to 55
Terminal Capacity (Max) sq.mm 25
Protection Class IP 20
Mounting Right side of the MCB Factory (Assembled)
Case & Cover Moulded, flame retardant thermoplastic material.
Standard Conformity IS / IEC : 60947-1
Type/Series
Rated Current (In) A 6A
Rated Voltage (ac) (Ue) V 240V
Rated Frequency (f) Hz 50
Contact Configration 1 NO+1 NC/ 2NO+2NC
Utilization Category AC 11
Rated Insulation Voltage (Ui) V 690
Rated Impulse Voltage (Uimp) kV 4
Electrical Endurance (Nos.) 1000
Ambient Temperature (oC) -5 to 55
Terminal Capacity (Max) sq.mm 4
Protection Class IP 20
Mounting Left side of the MCB Factory (Assembled)
Case & Cover Moulded, flame retardant thermoplastic material.
13
MCB SELECTION CHART
MINIATURE CIRCUIT BREAKER
ApplianceCapacity / wattage
(1φ, 240V~)MCB
Current RatingMCBType
Air Conditioner 1.0 Ton 10A “C” series
1.5 Ton 16A “C” series
2.0 Ton 20A “C” series
Refrigerator 165 litres 3A “C” series
350 litres 4A “C” series
Oven cum Griller 4500W 32A “B” series
1750W 10A “B” series
Oven 750W 6A “B” series
Hot plate 2000W 10A “B” series
Room Heater 1000W 6A “B” series
2000W 10A “B” series
Washing Machine 300W 2A “C” series
Washing Machine
(with heater) 1300W 8A “C” series
Water Heater
(storage/instant) 1000W 6A “B” series
2000W 10A “B” series
3000W 16A “B” series
6000W 32A “B” series
Electric iron 750W 6A “B” series
1250W 8A “B” series
Toaster
(2 slices) 1200W 8A “B” series
Electric Kettle 1500W 10A “B” series
Note : One lighting circuit can have up to 800W or up to 10 lighting points
One power circuit can have up to 2000W or 1 power points
“C” series MCB is used for all Motor Applications
Incomer Current Rating, For Three Phase :
Total Load in Watts
240V
Total Load in Watts
√3X240V
Calculation Formula :
Incomer Current Rating, For Single Phase :
RATING OF MCBS FOR SPECIFIED NO. OF FITTINGS (“B” SERIES MCBS)
“B” series MCB is used for all Lighting Applications
Lamp (Watt) Number of Lamps Rating (A)
20W8 1
12 1.5
40W
2 0.5
10 2
12 2.5
60W
1 0.5
4 1.5
8 3
12 4
80W
1 0.5
2 1
5 2
8 4
12 5
100W
1 1
2 1.5
4 2.5
14
MCB HIGHER RATING
TECHNICAL SPECIFICATION
Dimensions (In mm)
* Current Ratings: 80 A, 100 A, 125 A** 1P Single Pole 3P Three Pole 2P Double Pole 4P Four Pole
Standard Conformity IS / IEC 60947 – 2
Type / Series C
Rated Current (In) A 80 – 125*
Rated Voltage (Ue) V~ 240/415
Rated Insulation Voltage (Ui) V 690
Rated Impulse Withstand Voltage (Uimp) kV 6
Rated Frequency Hz 50 / 60
No. of Poles 1P, 2P, 3P, 4P**
Rated Short Circuit Breaking Capacity (Icn) kA 10
Rated Ultimate Short Circuit Breaking Capacity (Icu) kA 10
Rated Service Short Circuit Breaking Capacity (Ics) 75% of Icu
Magnetic Release Setting (In) A (5 - 10)
Mechanical Life No. of Operations 20000
Electrical Life No. of Operations 5000
Ambient Temperature °C - 5 to + 55
Terminal Capacity mm2 50
Tightening Torque Nm 3.5
Protection Class IP 20
Installation Position Vertical / Horizontal
Mounting Clip on DIN Rail (35mm x 7.5mm)
79.553.026.5
SP DP TP
106.0
45.0
81.0
5.5
44.564.3
74.5
36.0
FP
MCB HIGHER RATING
FEATURES
• TripFreemechanism
• PositiveContactIndication
• ThermalandMagnetictripfunctionwith Hammer trip operation
• CurrentLimitingdesignforshortcircuitfault protection
RANGE
80A, 100A & 125A - ‘C’ Curve
EXECUTION
• SinglePole(1P),DoublePole(2P)
• ThreePole(3P),FourPole(4P)
SPECIFICATION
IS / IEC 60947-2
15
MCB HIGHER RATING
HIGHER RATING SP MCB (80A - 125A) ‘C’ SERIES,
(In accordance with IS/IEC 60947-2) 240/415V, 0 Hz, 10kA
Rating Pack Qty. SP Cat. No.
80A 6 DSMCCSPF080
100A 6 DSMCCSPF100
125A 6 DSMCCSPF125
HIGHER RATING DP MCB (80A - 125A) ‘C’ SERIES,
(In accordance with IS/IEC 60947-2) 240/415V, 50 Hz, 10kA
Rating Pack Qty. DP Cat. No.
80A 3 DSMCCDPF080
100A 3 DSMCCDPF100
125A 3 DSMCCDPF125
HIGHER RATING TP MCB (80A - 125A) ‘C’ SERIES,
(In accordance with IS/IEC 60947-2) 240/415V, 50 Hz, 10kA
Rating Pack Qty. TP Cat. No.
80A 2 DSMCCTPF080
100A 2 DSMCCTPF100
125A 2 DSMCCTPF125
HIGHER RATING FP MCB (80A - 125A) ‘C’ SERIES,
(In accordance with IS/IEC 60947-2) 240/415V, 50 Hz, 10kA
Rating Pack Qty. FP Cat. No.
80A 1 DSMCCFPF080
100A 1 DSMCCFPF100
125A 1 DSMCCFPF125
16
ISOLATOR
TECHNICAL SPECIFICATION
SWITCH DISCONNECTOR (ISOLATORS)
Rating (A) Cat No.
40 DSMISOSPX040
63 DSMISOSPX063
100 DSMIOSPX100
125 DSMIOSPX125
Rating (A) Cat No.
40 DSMISOSPX040
63 DSMISOSPX063
100 DSMIOSPX100
125 DSMIOSPX125
ISOLATOR SINGLE POLE (SP)
ISOLATOR DOUBLE POLE (DP)
Standard Conformity IS / IEC 60947 - 3
Type/Series
Rated Current (In) A 40A, 63A, 100A and 125A
Rated Voltage (ac) (Ue) V 240/415
Rated Frequency (f) Hz 50
Nos. of Poles (Execution) SP, DP, TP & FP
Utilization Category Magnetic Release Setting
AC 22A in 40A & 63AC 23A in 100A & 125A
Rated Insulation Voltage (Ui) V 690
Rated Impulse Voltage (Uimp) kV 4
Electrical Endurance (Nos.) 10000
Mechanical Endurance (Nos.) 20000
Ambient Temperature (oC) -5 to 55
Terminal Capacity (Max) for 40A to 63A
sq.mm Flexible 16 & Solid 25
Terminal Capacity (Max) for 100A to 125A
sq.mm Flexible 35 & Solid 50
Vibration 5
Shock 40mm free fall
Protection Class IP 20
Installation Position Vertical / Horizontal
Mounting Clip on DIn Rail (35 mm x 7.5 mm)
Case & Cover Moulded, flame retardant thermoplastic material.
17
ISOLATOR
Rating (A) Cat No.
40 DSMISOSPX040
63 DSMISOSPX063
100 DSMIOSPX100
125 DSMIOSPX125
Rating (A) Cat No.
40 DSMISOSPX040
63 DSMISOSPX063
100 DSMIOSPX100
125 DSMIOSPX125
ISOLATOR TRIPLE POLE (TP)
ISOLATOR FOUR POLE (FP)
18
MCB CHANGEOVER SWITCH
19
MCB Changeover switch finds wide & varied applications in industries as well as in domestic sphere for use in low voltage distribution circuits, wherever continuity of supply is necessary, for switching to an alternate source of supply from main supply and vice - versa.
These are switch disconnectors with independent manual operation, capable of making, carrying and breaking currents under normal circuit conditions, which may include operating overload condition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time.
FEATURES
• Compactconstruction
• Doublebreakcontacts
• SilverCadmiumOxidecontacttips
• Shroudedterminals
• FrontoperationwiththreestablepositionsI-O-II
• CentrepositionOFF
• EasysnaponDINRailmounting
• Canbemountedwithotherproductsviz.MCB,RCCB,Isolatorin Distribution Board
CONSTRUCTION
The entire switching mechanism along with the fixed and moving contact assembly are housed in FR thermo plastic moulded case / cover, having high dielectric strength, excellent mechanical & thermal properties.The switching mechanism is double break type. The contact tips are made of Silver Cadmium oxide for long electrical life, sustained current carrying capacity and ensure temperature rise is within specified limit.
TECHNICAL INFORMATION
Standard Conformity IS / IEC 60947 - 3
Type/Series
Rated Current (In) A 25 & 40
Rated Voltage (ac) (Ue) V 240/415
Rated Frequency (f) Hz 50
Nos. of Poles (Execution) DP & FP
Utilization Category AC 21A
Dielectric Strength kV 2.5
Rated Insulation Voltage (Ui) V 690
Rated Impulse Voltage (Uimp) kV 4
Electrical Endurance (Nos.) 10000
Mechanical Endurance (Nos.) 10000
Ambient Temperature (oC) -5 to 55
Terminal Capacity (Max) for sq.mm 10
Shock 40mm free fall
Protection Class IP 20
Installation Position Vertical / Horizontal
Mounting Clip on DIn Rail (35 mm x 7.5 mm)
Case & Cover Moulded, flame retardant thermoplastic material.
20
DOUBLE POLE - CONNECTION DIAGRAMS / TERMINAL MARKING
MCB CHANGEOVER SWITCH
“I” - Incoming terminals (main supply) - 2 & 6
“II” - Incoming terminals (standby supply) - 4 & 8
Outgoing terminals (to load) - 1 & 5
* Mid position of knob is in 'OFF' position
1 3
2 4 6 8
5 7
DIMENSIONS (in mm)
Current Rating (Amps.) Cat No.
25 DSMCODPX025
40 DSMCODPX040
63 DSMCODPE063
21
FOUR POLE - CONNECTION DIAGRAMS / TERMINAL MARKING
MCB CHANGEOVER SWITCH
“I” - Incoming terminals (main supply) - 2, 6, 10 & 14
“II” - Incoming terminals (standby supply) - 4, 8, 12 & 16
Outgoing terminals (to load) - 1, 5, 9 & 13
*Mid position of knob is in 'OFF' position
1 5
161412
9 13
108642
DIMENSIONS (in mm)
Current Rating (Amps.) Cat No.
25 DSMCOFPX025
40 DSMCOFPX040
63 DSMCOFPE063
22
RESIDUAL CURRENT CIRCUIT BREAKER (RCCB / ELCB)
23
The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical device causes current to flow through the wrong path (i.e. through the insulation) to the earth. This current is called ‘Leakage Current’.
Earth leakage is an electrical hazard and is responsible for electrical shocks and fire risk. Earth leakage and its associated hazard can be prevented by Residual Current Circuit Breaker (RCCB), also popularly known as Earth Leakage Circuit Breaker (ELCB).
FEATURES
• Simpleandrobustoperatingmechanism
• RotaryhandlewithON/OFFindication
• DualterminationforBusBaraswellascableconnection
• Advanceneutral
• Testbuttonforregularinspection
• Positivecontactindication
RANGE
16A - 63A
SENSITIVITY
30mA, 100mA, 300mA
EXECUTION
• DoublePole(DP)
• FourPole(FP)
SPECIFICATIONIS 12640 - Part 1 IEC / EN 61008-1
24
RCCB/ELCB
PROTECTION - AGAINST ELECTROCUTIONThe use of exposed, substandard, badly wired, wrongly connected or damaged equipment as well as frayed or badly repaired cables reduces the safety of an installation and increases the risk of person receiving an electric shock.
Electrocution is a passage of current through human body, which is dangerous. The flow of current through human body effects vital functions.
1. Breathing
2. Heartbeat
A correctly chosen RCCB can detect current flowing into earth and reduces the risk of electrocution. Effect of electric current through human body has been well researched and following chart summarizes the results.
Effect of electric current through human body has been well researched and following chart summarizes the results.
However, electrocution should not be viewed in terms of “current” alone, but in terms of “contact voltage”. A person gets electrocuted by coming in contact with an object that has a different potential from his/her own. The difference in potential causes the current to flow through the body.
The human body has known limits:
•Undernormaldryconditions,voltagelimit=50V
•Indampsurroundings,voltagelimit=25V
EFFECT OF ELECTRIC CURRENT THROUGH HUMAN BODY
AGAINST INDIRECT CONTACT
Over current protection devices like MCB are unable to act promptly on small earth leakage currents. To comply with wiring regulations, the earth fault loop impedance in Ohms, multiplied by the rated tripping current of the RCD in amperes must not exceed 50.
EXAMPLE
For an RCD with a rated tripping current of 30mA, the maximum permissible earth fault loop impedance is calculated as follows: Zs (max) = 50 / In = 50/0.03 = 1,666
AGAINST FIRE
The majority of fires which occur as a result of faulty wiring are started by current flowing to earth. Fire can be started by fault current of less than 1 amp.The normal domestic overload protective device such as a fuse or MCB will not detect such a small current. A correctly chosen RCD will detect this fault current and interrupt the supply, hence, reducing the risk of a fire starting.
500 mA Immediate cardiac arrest resulting in death
70-100 mA Cardiac fibrillation; the heart begins to vibrate and no longer beats at a steady rate.
This situation is dangerous since it is irreversible
20-30 mA Muscle contraction can cause respiratory paralysis
10 mA Muscle contraction : the person remains “stuck” to the conductor
1-10 mA Prickling sensations
Rated Tripping Current Maximum permissible of the RCD earth fault loop impedance in
10 mA 5,000 30 mA 1,666 100 mA 500 300 mA 166
25
Technical Information 2P 4P
Standard Conformity IS 12640-1: IEC/ EN 61008-1 IS 12640-1: IEC / EN 61008-1
Rated Current (In) A 16, 25, 32, 40, 63 25, 40, 63
Sensitivity * (In) mA 30, 100, 300 30, 100, 300
Rated Voltage (Un) Vac 240 415
Rated Insulation Voltage (Ui) V 690 690
Rated Frequency Hz 50 50
Short circuit Withstand Capacity kA 6 6
Residual Making Breaking Capacity A 500 A or 10 In wherever is greater 500 A or 10 In wherever is greater
Ambient Temperature °C -25°C to + 55°C -25°C to + 55°C
Shock Resistance 40 mm free fall 40 mm free fall
Vibration Resistance g 3 3
Electrical /Mechanical operations 10000 10000
Mounting Din Rail (35 x 7.5) mm Din Rail (35 x 7.5) mm
Degree of Protection IP 20 IP 20
Terminal Capacity (max) mm2 25 25
RCCB/ELCB
WORKING PRINCIPLEThe RCCB works on the current balance principle. The supply conductors, i.e. the phases and the neutral, are passed through a torroid and form the primary windings of a current transformer. Its secondary winding is connected to a highly sensitive electromagnetic trip relay, which operates the trip mechanism.
In a healthy circuit, sum of the currents in phases, is equal to the current in the neutral and the vector sum of all currents is equal to zero. If there is any insulation fault in the current and leakage current flows to earth, the currents do not balance and their vector sum is not equal to zero. This imbalance is detected by the core balanced current transformer, the RCCB is tripped and supply to load is interrupted. The trip mechanism is operated at a residual current between 50-100% of its rated tripping current.
Earth
R
Y
B
N
T
*500 mA is available on request
26
WIRING DIAGRAM
The STANDARD range of four pole RCCBs can be used to provide residual current protection in 3 phase, 3 wire circuits (no neutral), however a link from the neutral to an incoming should be made on the supply side of the RCCB, to enable the operation of the RCCB.
Actuation Time Characteristics
RCCB/ELCB
a
Current in milliamperes
b c1c2c310000
5000
2000
1000
500
200
100
50
20
100.1 0.3 1 3 10 30 100 300 1000 3000 10000
0.2 0.5 2 5 20 50 200 500 2000 5000
30 mA
100 mA
Tim
ein
milli
seco
nds
Typical currentlimits due to body resistanceat 240 V
ms
350
300
350
200
150
100
50
1 2 3 4 5 6
Residual Current multiple of IΔn (mA)
Tim
e (in
ms)
For Three Phase 3 Wire connections
For Single Phase 2 Wire connections
For Three Phase 4 Wire connections
Load
1 N
Load
2 4 6 N
Load
2 4 6 N
2 N 2 4 6 N
1N
T
R
1 3
R
T
5 N 1 3 5 N
2 4 6 N
R
T
SELECTION
30 mA : A 30 mA ELCB will provide a high degree of protection against
electrocution in an accidental shock hazard situation. The current flowing
through human body could be between 80mA and 240mA depending on
the resistance of the human body and the voltage across it.
Zone : Physiological Effects
Zone 1 : Usually no reactions
Zone 2 : Usually no harmful physiological effects
Zone 3 : Usually no organic damage to be expected. Likelihood of muscular
contraction and difficulty in breathing, reversible disturbances of formation
and conduction of impulse in the heart and transient cardiac arrest without
ventricular fibrillation increases with current magnitude and time.
Zone 4 : In addition to the effects of Zone 3, probability of ventricular
fabriliation increases upto 5% (curve C2) upto 50% (curve C3) and
above 50% beyond curve C3. It increases with magnitude and time, and
pathophysiological effects such as cardiac arrest, breathing arrest and heavy
burns may occur.
To be within zone of the IEC curve as shown above. It is necessary for the
ELCB to operate within 50ms at 240 mA and 150ms at 80mA. Both these
conditions are satisfied by 30mA ELCB.
For households, individual outlets, wet areas and temporary installations,
ELCB with sensitivity not exceeding 30mA is advisable.
100 mA : A 100mA ELCB will normally give high degree of protection
against electrocution but there is a possibility that the shock current could
fall below the tripping level of ELCB. This could occur if additional resistances
to that of human body are included in the earth path.
The 100mA RCCB protects against leakage current and indirect contact with
earth loop impedance upto 500 Ohms.
300 / 500mA : A 300/500 mA ELCB may be used where only fire protection
is required. eg., on lighting circuits, where the risk of electric shock is lesser.
300/500mA ELCB will not give any protection against electrocution.
27
Dimensions (in mm)
RCCB/ELCB
36.0
36.0
45.0
67.8
60.0
71.0
68.0
60.0
43.5
84.5
36.0
45.0
AC TYPE - STANDARD APPLICATIONSAC type RCDs detect AC residual current. In the majority of cses (standard applications), they are used for AC current detection at 50 / 60 Hz
CurrentRating (Amps.)
Cat No.B-Curve C-Curve
16 30 DSRMCTDF030016
16 100 DSRMCTDF100016
16 300 DSRMCTDF300016
25 30 DSRMCTDF030025
25 100 DSRMCTDF100025
25 300 DSRMCTDF300025
32 30 DSRMCTDF030032
32 100 DSRMCTDF100032
32 300 DSRMCTDF300032
40 30 DSRMCTDF030040
40 100 DSRMCTDF100040
40 300 DSRMCTDF300040
63 30 DSRMCTDF030063
63 100 DSRMCTDF100063
63 300 DSRMCTDF300063
CurrentRating (Amps.)
Cat No.B-Curve C-Curve
16 30 DSRMCRFF030016
16 100 DSRMCRFF100016
16 300 DSRMCRFF300016
25 30 DSRMCRFF030025
25 100 DSRMCRFF100025
25 300 DSRMCRFF300025
32 30 DSRMCRFF030032
32 100 DSRMCRFF100032
32 300 DSRMCRFF300032
40 30 DSRMCRFF030040
40 100 DSRMCRFF100040
40 300 DSRMCRFF300040
63 30 DSRMCRFF030063
63 100 DSRMCRFF100063
63 300 DSRMCRFF300063
DOUBLE POLE ‘AC’ TYPE
FOUR POLE ‘AC’ TYPE
28
RCCB/ELCB
*500 mA is available on request
HIGHER RATING RCCB (80A-100A)
Technical Specification 2P 4P
Specification reference IS 12640-1 IEC / EN 61008-1 IS 12640-1 IEC / EN 61008-1
Rated current (In) A 80, 100 80, 100
Sensitivity (IDn) mA 30, 100, 300 30, 100 ,300, 500*
Rated voltage (Ue) V 240 ac 415 ac
Rated insulation voltage (Ui) V 690 690
Rated frequency Hz 50 50
Trip time 1xIDn<300ms 1xIDn<300ms 5IDn<40ms 5IDn<40ms
Short circuit withstand capacity kA 10 10
Residual making breaking capacity A 10 In 10 In
Ambient working temperature °C -25°C to + 55°C -25°C to + 55°C
Shock resistance 40mm free fall 40mm free fall
Vibration resistance g 3 3
Electrical endurance operations >2000 >2000
Mechanical endurance operations >3000 >3000
Mounting Din Rail (35 x7.5 mm) Din Rail (35 x7.5 mm)
Degree of protection IP 20 IP 20
Terminals capacity (Max) mm2 50 50
FEATURES
•Shortcircuitbreakingwithstandcapacity10kA
•DifferentknobpositiontoindicatewhetheritisswitchedbyafaultormanuallyswitchedOFF(midtrip)
•Testbuttonforregularinspection
•Contactpositionindication
29
DOUBLE POLE ‘AC’ TYPE
FOUR POLE ‘AC’ TYPE
Dimensions (in mm)
RCCB/ELCB
36.0
30.5
44.0
60.0
69.5
45.0
36.0
87.5 87.5
72.0
2 Pole 4 Pole
Current Rating (Amps.) Sensitivity Cat No.
80 30 DSRMCMDF030080
80 100 DSRMCMDF100080
80 300 DSRMCMDF300080
100 30 DSRMCMDF030100
100 100 DSRMCMDF100100
100 300 DSRMCMDF300100
Current Rating (Amps.) Sensitivity Cat No.
80 30 DSRMCMDF030080
80 100 DSRMCMDF100080
80 300 DSRMCMDF300080
100 30 DSRMCMDF030100
100 100 DSRMCMDF100100
100 300 DSRMCMDF300100
30
RESIDUAL CURRENT CIRCUIT BREAKER WITH OVER CURRENT PROTECTION (RCBO)
31
STANDARD new RCBO is a single composite device which provides protection against over current and earth leakage faults in the same width and profile as that of a standard MCB. It is designed for use in domestic, commercial and industrial distribution systems at the most downstream circuit for ensuring high degree of protection to the user for a particular circuit. In normal use, it is safe to use and free of to user as well as to environment.
FEATURES
• Pulsatingdcprotection-TypeA
• Discriminationusingtimedelay-TypeSRCBO
• ControlledresponseVDRCBO(Electronic)
• ProtectionincaseoflossofsupplyneutralinSPNRCBOonly
• Enhancedimmunitytonuisancetripping
• Positivecontactindication:RedforON,GreenforOFF
• Shortcircuitbreakingcapacity10kA
• Largeterminalcapacity:RCBOshave35mm2forcoolrunningwhileinoperation
• Protectionincaseoflossofsupplyneutral:Evenineventoflossofsup-ply neutral, STANDARD RCBO provides protection against earth faults . The Functional Earth (FE) white color wire connected to earth provides this protection
• Controlledresponse&immunitytonuisancetripping:Thetriplevelandthe response time of the STANDARD VD (Voltage Dependent) RCBO using electronic circuit is set to very precise values and thereby provide greater immunity to nuisance tripping that can be caused by mains borne noise, surge voltages, lighting surges, reactive loads, mains filters, etc
• Neutraltoearthfaults:AconnectionthatoccursbetweenNandEonthe load side of any RCBO will impact on its performance and cause the trip level to increase. In the case of a N - E fault, the user may have no way of knowing that this fault exists and that the RCBO has been desensitised. Under this condition, the Standard VD RCBO provides a far greater level of protection than a normal VI (Voltage Independent) RCBO
AESTHETICS & CONVENIENCE
• Thenewmodule’suniquecompactconstructionenablesfarmoredevices to be fitted into a distribution board than previously possible, and 2 Module RCBO can simply replace existing MCB 2 pole when upgrading a board.
• Highstackingdensity=smallerchasis&distributionboards.
Reliability & continuity of service
• EnhanceddiscriminationwithSTANDARDMCBs
• Backupto10kAwithBS&DINfuses
• RetrofitsStandardMCBsindistributionboardswithnomodificationsingeneral
• Robustconstruction.
ENERGY LIMITING
STANDARD RCBO meets the requirements for energy let through by IEC &British Standard for energy limiting class 3.
32
ADDITIONAL RANGE - TYPE A & SType A - Pulsating DC Protection: Any electrical appliance with power control has the ability to produce earth fault current with pulsating DC (rectified AC) components. RCBOs that provide this type of protection are referred to as Type A RCBOs.
VI RCBOs do not provide this protection, and are referred to as Type AC RCBOs. STANDARD VD RCBOs have been specifically designed to provide protection against pulsating DC fault currents.
• TypeS-SelectiveorTimeDelay:RCBOsarealsodividedintotwocategoriesdeterminedbytheirresponsetimetoanearthfaultcurrent,asfollows
• GeneralType-havingatriptime<300mSforfaultcurrentsofIDNand<40msforfaultcurrents>5IDN.
• SType-havingatriptimeof150-500mSforIDN,and40-130mSfor>5IDN.
(IDn is the rated residual operating current of the RCBO)
As the name implies, general types are intended for general purpose use. However, S (selective) types are normally used in conjunction with downstream general type RCBOs.
The S type effectively provides discrimination in terms of the response time to earth fault currents for upstream and downstream RCBOs. For example, when two RCBOs are connected in series the first RCBO will often be an S type.
Technical Information SPN (2M) TPN (4M)
Specification SPN (2M) TPN (4M)Specification reference IS 12640 (Part 2) & IEC 61009 IS 12640 (Part 2) & IEC 61009Rated current In 6A, 10A, 16A, 20A,25A, 32A, 40A 6A, 10A, 16A, 20A,25A, 32A, 40ARated residual operating current IDN 30, 100, 300mA. 30, 100, 300mA.Instantaneous tripping current ‘C ’curve ‘C ’curveRated voltage Un (Vac) 240V~ 415V~Rated insulation voltage Un (Vac) 690V 690VRated frequency 50Hz 50HzNo. of pole 1P+N 3P+NRated short circuit capacity Icn 10kA 10kARated residual making breaking capacity IDm 500A 500A Operating characteristics in case of residual currents ‘A’ type ‘A’ typeMethod of mounting Panel board type (DIN rail) Panel board type (DIN rail)Degree of protection IP 20 IP 20Terminals for external conductors (mm2) 35 Net weight (in Kg) 0.420 0.840Ambient working temperature -5°C to + 55°C -5°C to + 55°CMechanical endurance (No. of operations) 4000 4000Electrical endurance (No. of operations) 4000 4000Trip time (milli second) <40 <40Shock resistance 40mm free fall 40mm free fallVibration resistance 3g 3g
RCBO
33
RCBO
Dimensions (in mm)
10000.00
1000.00
100.00
Tim
e (s
ec)
10.00
1.00
0.10
0.011 10
Multiples of Reted Current
100
1000.00
100.00
Tim
e (s
ec)
10.00
1.00
0.10
0.010.01 1 10 100 1000 10000
Multiples of Reted Residual Current in I∆n mA
Time Current Characteristics C Curve Residual Current Tripping Characteristics (General Type)
35.4
87.5
36
43.5
68.4
45
70.6
6.8
44
70.8 50.4
4536
6.8
43.568.474.5
125
CurrentRating (Amps.)
SensitivitymA
Cat No.SP&N
Cat No.TP&N
6 30 DSCEACSN2030006 DSCEACTN4030006
6 100 DSCEACSN2100006 DSCEACTN4100006
6 300 DSCEACSN2300006 DSCEACTN4300006
10 30 DSCEACSN2030010 DSCEACTN4030010
10 100 DSCEACSN2100010 DSCEACTN4100010
10 300 DSCEACSN2300010 DSCEACTN4300010
16 30 DSCEACSN2030016 DSCEACTN4030016
16 100 DSCEACSN2100016 DSCEACTN4100016
16 300 DSCEACSN2300016 DSCEACTN4300016
20 30 DSCEACSN2030020 DSCEACTN4030020
20 100 DSCEACSN2100020 DSCEACTN4100020
20 300 DSCEACSN2300020 DSCEACTN4300020
25 30 DSCEACSN2030025 DSCEACTN4030025
25 100 DSCEACSN2100025 DSCEACTN4100025
25 300 DSCEACSN2300025 DSCEACTN4300025
32 30 DSCEACSN2030032 DSCEACTN4030032
32 100 DSCEACSN2100032 DSCEACTN4100032
32 300 DSCEACSN2300032 DSCEACTN4300032
40 30 DSCEACSN2030040 DSCEACTN4030040
40 100 DSCEACSN2100040 DSCEACTN4100040
40 300 DSCEACSN2300040 DSCEACTN4300040
34
DISTRIBUTION BOARDS & ENCLOSURES
35
Distribution Boards provide flexibility and a systematic approach to ever increasing need for effective methods of the electrical distribution in domestic, commercial and industrial application. STANDARD distribution boards have been specially designed to meet all the technical requirements and ensures the distribution boxes blend with the decor of the installation space.The distribution boards with their features and their range offer a compact, practical and economic solution to any electrical network in residential / commercial complexes, industries etc. having single phase or three phase connections. The distribution board is not merely an enclosure but a complete system in itself comprising of ETP Copper bus bar, brass neutral link, earth link, earthing studs, and interconnection wires for effective distribution of current.
FEATURES
• Superioraestheticsthatblendwellwiththedecor
• MadeofspecialgradeCRCAsheetsteeltoprovidestrengthandlongerlife to enclosures
• ManufacturedwithlatesttechnologyCNCPunchandBrakepressestoattain highest degree of perfection
• Paintedwithepoxypolysterandpolysterresinbasedpowderpaintswithlatest techniques in powder coating ensures strong, scratch resistant coatings
• Currentcarryingpartsaremadeofelectrolyticgradeofcopperhavinghigh conductivity and low resistivity thereby keeping temperature rise and distribution loss very low
• Appropriate sizes of DIN rails to facilitate easy and fast mounting ofMCBs, RCCBs, Isolators etc
• Brassneutralandearthbarsofsuitablecross-sectionalareasareprovidedto facilitate connections for each outgoing terminals
• Adequatenumberofknockoutholesofvarioussizesareprovidedbothat the top and the bottom. This facilitate easy installation and connection of conduits of all sizes, both for top and bottom
• Detachableupperandlowerendplatesprovidedforeasyandflexibilityof cabling
• Superiorsinglephasebusbarsprovidedwhicharecompletelyinsulatedand fitted in PVC channel to avoid accidental touch
• Suitableforbothflushandsurfacemounting
• ConformstoIS13032&IEC:61439-3
• Robustconstruction
36
DISTRIBUTION BOARDS
S.No. Type Configuration Application
(a) SPN SPN Simple, Economical & Safe distribution Consumer Simple, Economical & Safe distribution
(b) TPN TPN (Horizontal & Three phase & neutral incoming and outgoing can be only single phase Vertical) Three phase and neutral incoming, outgoing can be single phase as well as multi phase Per Phase Isolation (PPI) DP RCCB in each phase is provided to avoid the total outage as only the phase where earth leakage fault exist, get isolated. (c) Special Extended loose Wire Most flexible design Three Tier Most flexible design Power Line For fault level higher then 10kA with a provision for MCCB incomer 7 Segment DB Single point distribution where per phase isolation facility is required Phase Selector(40&63A) Used for selection of a phase in case other phase fails Plug & Socket Used for Air conditioner and motor protection MCB Enclosures To isolate / connect electrical appliances independently
RANGE
Outer door
DISTRIBUTION BOARDS
FEATURESMasking - (Cement & Water guard)
During the construction stage the DBs can get ingressed with water & cement dust. This can spoil the decor and more importantly alter the performance parameters. STANDARD Smart Trek DBs come with a masking arrangement that keeps water and cement dust away.
WEATHER PROOF DESIGN
All DBs are provided with perfect fitted gaskets which ensures maximum ingress protection upto IP-43.
Note: All features are not available in all types of DBs
Inner door
Masking (Cement & waterguard)
37
Dimensions (in mm)
Ways Powershell DescriptionCat No.
SPN Double Door
Dimensions Knockout holes
A B C D
Top Bottom Side (Each Side)(Ø25) (Ø31) (Ø25) (Ø25)
4 SPN 4W DD DB DSDPSHODIW04 125 175 207 172 3 - 3 - 1
6 SPN 6W DD DB DSDPSHODIW06 151 211 243 166 3 - 3 - 1
8 SPN 8W DD DB DSDPSHODIW08 187 247 279 166 2 2 2 2 1
12 SPN 12W DD DB DSDPSHODIW12 269 319 349 176 4 2 4 2 1
16 SPN 16W DD DB DSDPSHODIW16 341 423 412 172 4 2 4 2 1
Knockout holes O/G
Knockout holes I/C
Knockout holeson each side
D 222
1280
.63
243
AB
C
DISTRIBUTION BOARDS
RANGE
Powershell SPN DD - 4, 6, 8, 12 & 16W
SPECIFICATION
IS: 13032 & IEC 61439 - 3
FEATURES
• AestheticallyPleasingDesign
• Elegentcolorcombination
• Cornersofthetopcoverhavebeenbeautifullycoveredwithnewunique design of side channels.
• TransparentcementguardtoprotecttheDBfromconstructionspill over.
SPN POWERSHELL DOUBLE DOOR DISTRIBUTION BOARDS - IP 42
Dimensions (in mm)
Ways Powershell Description Cat No.
Dimensions Knockout holes (Ø31)
A B C Top Bottom
Side (Each Side)
4 TPN 4W DD DB DSDPTHODIW04 196 251 282 4 4 2
6 TPN 6W DD DB DSDPTHODIW06 268 323 345 6 6 2
8 TPN 8W DD DB DSDPTHODIW08 340 395 430 6 6 2
12 TPN 12W DD DB DSDPTHODIW12 479 534 569 8 8 2
TPN POWERSHELL DOUBLE DOOR DISTRIBUTION BOARDS - IP 42
Knockout Holes O/G
Knockout holeson each side
345
400
421
Knockout Holes I/C
A
1292
3
B
C
DISTRIBUTION BOARDS
RANGE
Powershell TPN DD - 4, 6, 8 & 12W
SPECIFICATION
IS: 13032 & IEC 61439 - 3
FEATURES
• AestheticallyPleasingDesign
• Elegentcolorcombination
• Cornersofthetopcoverhavebeenbeautifullycoveredwithnewunique design of side channels
• TransparentcementguardtoprotecttheDBfromconstructionspill over
DISTRIBUTION BOARDS
SPN POWERSHELL DOUBLE DOOR DISTRIBUTION BOARDS - IP 43
Dimensions (in mm)
WaysPowershell Description Cat No.
Dimensions Knockout holes
A B C D
Top Bottom Side (Each Side)(Ø25) (Ø31) (Ø25) (Ø25)
4 SPN 4W DD DB DSDNSHODIW04 125 175 207 172 3 - 3 - 1
6 SPN 6W DD DB DSDNSHODIW06 151 211 243 166 3 - 3 - 1
8 SPN 8W DD DB DSDNSHODIW08 187 247 279 166 2 2 2 2 1
12 SPN 12W DD DB DSDNSHODIW12 269 319 349 176 4 2 4 2 1
16 SPN 16W DD DB DSDNSHODIW16 341 423 412 172 4 2 4 2 1
DISTRIBUTION BOARDS
Knockout holes O/G
Knockout holes I/C
Knockout holeson each side
D 222
1280
.63
243
AB
C
RANGE
Powershell SPN DD - 4, 6, 8, 12 & 16W
SPECIFICATION
IS: 13032 & IEC 61439 - 3
FEATURES
• AestheticallyPleasingDesign
• Elegentcolorcombination
• Cornersofthetopcoverhavebeenbeautifullycoveredwithnewunique design of side channels
• TransparentcementguardtoprotecttheDBfromconstructionspill over
• BetteringressofprotectionIP43
DISTRIBUTION BOARDS
40
DISTRIBUTION BOARDS
Dimensions (in mm)
WaysPowershell Description Cat No.
Dimensions Knockout holes (Ø31)
A B C Top BottomSide (Each
Side)
4 TPN 4W DD DB DSDNTHODIW04 196 251 282 4 4 2
6 TPN 6W DD DB DSDNTHODIW06 268 323 345 6 6 2
8 TPN 8W DD DB DSDNTHODIW08 340 395 430 6 6 2
12 TPN 12W DD DB DSDNTHODIW012 479 534 569 8 8 2
TPN POWERSHELL DOUBLE DOOR DISTRIBUTION BOARDS - IP 43
Knockout Holes O/G
Knockout holeson each side
345
400
421
Knockout Holes I/C
A
1292
3
B
C
RANGE
Powershell SPN DD - 4, 6, 8 & 12W
SPECIFICATION
IS: 13032 & IEC 61439 - 3
FEATURES
• AestheticallyPleasingDesign
• Elegentcolorcombination
• Cornersofthetopcoverhavebeenbeautifullycoveredwithnewunique design of side channels
• TransparentcementguardtoprotecttheDBfromconstructionspill over
• BetteringressofprotectionIP43
41
Dimensions (in mm)
Ways Cat No.
Dimensions Knockout holes
A B C D
Top Bottom Side(Each Side)φ25 φ31 φ25 φ31
2 + 4W DSDCSHODOW04 151 211 243 166 3 - 3 - 1
2 + 6W DSDCSHODOW06 187 247 279 166 2 2 2 2 1
2 + 8W DSDCSHODOW08 233 283 315 176 2 2 2 2 1
2 + 10W DSDCSHODOW10 269 319 351 176 4 2 4 2 1
2 + 12W DSDCSHODOW12 305 355 387 172 4 2 4 2 1
2 + 14W DSDCSHODOW14 341 391 423 172 4 2 4 2 1
SPN POWERSHELL 2+DOUBLE DOOR DBS - IP 42
Knockout holes O/G
Knockout holes I/C
Knockout holeson each side
A
B
C
243
222
D
94
123
DISTRIBUTION BOARDS
RANGE
Powershell SPN DD - 4, 6, 8, 12 & 16W
SPECIFICATION
IS: 13032 & IEC 61439 - 3
FEATURES
• AestheticallyPleasingDesign
• Elegentcolorcombination
• Cornersofthetopcoverhavebeenbeautifullycoveredwithnewunique design of side channels
• TransparentcementguardtoprotecttheDBfromconstructionspill over
• Properisolationbetweenincomer&outgoing
42
SPN SINGLE DOOR DBs IP 40
Knockout Holes - Dimensions (in mm)
61
232
222
182
C
B
10
A
(fixi
ng c
ente
r)
(fixing center)
Ways Cat No.
Dimensions
A B C Top Bottom Each Side
4 DSDMSNHOSI04 139 68 149 3 No. Ø25 - No. Ø31 3 No. Ø25 - No. Ø31 1 No. Ø25
6 DSDMSNHOSI06 175 104 185 2 No. Ø25 1 No. Ø31 2 No. Ø25 1 No. Ø31 1 No. Ø25
8 DSDMSNHOSI08 211 140 221 2 No. Ø25 2 No. Ø31 2 No. Ø25 2 No. Ø31 1 No. Ø25
12 DSDMSNHOSI12 283 212 293 2 No. Ø25 2 No. Ø31 2 No. Ø25 2 No. Ø31 1 No. Ø25
16 DSDMSNHOSI16 355 284 365 4 No. Ø25 2 No. Ø31 4 No. Ø25 2 No. Ø31 1 No. Ø25
RANGE
SPN DD - 4, 6, 8, 12 & 16W
SPECIFICATION
IS: 13032 & IEC 61439 - 3
FEATURES
• Compactdesign,requiresminimumspace
• Suitableforflush&surfacemounting
• Suppliedwithfullyshieldedbusbar
• Levelmarksforprovidingindicationforfitmentinwall
DISTRIBUTION BOARDS
43
(fixing center)
(fix
ing
cent
er)
B
C
400
345
A
76
410
D
Ways Cat No.
Dimensions
Sheet Thickness
Knockout holes (Ø31)
A B C D Top BottomSide (Each
Side)
4 DSDMTNHCSI04 251 192 261 72 1.0 4 4 2
6 DSDMTNHCSI06 323 264 333 144 1.0 6 6 2
8 DSDMTNHCSI08 395 336 405 144 1.0 6 6 2
12 DSDMTNHCSI12 539 480 549 144 1.0 8 8 2
Dimensions (in mm)
TPN SINGLE DOOR DBs IP 40 PROTECTION
Range SPN DD - 4, 6, 8, 12 & 16W
SPECIFICATION
IS: 13032 & IEC 61439 - 3
FEATURES
• Compactdesign,requiresminimumspace
• Raisedneutrallinkforeasywiring
• Suitableforflush&surfacemounting
• Suppliedwithfullyshieldedbusbar
• Levelmarksforprovidingindicationforfitmentinwall
DISTRIBUTION BOARDS
44
VERTICAL TYPE DBs - IP 42
395345
4058110
3
AB C
Dimensions (in mm) Single Door
Dimensions (in mm) Double Door
Knockout Holes (Ø31 & Ø38)
Knockout Holes (Ø31 & Ø38)
11
345
413
CB
395
3
108
A
Ways Cat No. A B C TopBottom
Ø31Bottom
Ø38 SideSheet
Thickness
4 DSDMTNVOSI04 450 400 460 5 2 1 2 1.0
8 DSDMTNVOSI08 558 508 568 5 2 1 2 1.0
12 DSDMTNVOSI12 666 616 676 5 2 1 2 1.0
Ways Cat No. A B C TopBottom
Ø31Bottom
Ø38 SideSheet
Thickness
4 DSDMTNVODI04 450 400 472 5 2 1 2 1.0
8 DSDMTNVODI08 558 508 580 5 2 1 2 1.0
12 DSDMTNVODI12 666 616 688 5 2 1 2 1.0
RANGE
TPN Vertical DB - 4, 8, & 12W
SPECIFICATION
IS: 13032 & IS: 8623 and IEC 61439 - 3
FEATURES
• Suitableforflush&surfacemounting
• Raisedneutrallinkforeasywiring
• ProvisionforFPIsolator/RCCBasincomer&SP/TPmcbasoutgoing
• Suppliedwith125Acopperbusbarflattype
• Suppliedwithneutral&earthbars
• Panassemblyforeaseofinstallation
DISTRIBUTION BOARDS
45
Ways Cat No. A B C TopBottom
Ø31Bottom
Ø38 SideSheet
Thickness
4 DSDPVDIBEOTO04 685 596 670 7 4 1 2 1.2
8 DSDPVDIBEOTO08 793 703 778 7 4 1 2 1.2
12 DSDPVDIBEOTO12 901 811 886 7 4 1 2 1.2
POWERLINE VERTICAL TYPE DBs - IP 42 PROTECTION
Dimensions (in mm)
CBA
3105
10365
350275
RANGE
Powerline DB - (TPN SD/DD) - 4, 8 & 12W
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & IS: 8623
FEATURES
• SuitableforFlushmountingandSurfacemounting
• With160A&250Acopperbusbar
• Withneutralbars&earthbars
• WithprovisionforTP/FP160MCCBasincomerand SP / TP MCBs as outgoing
• IP42
DISTRIBUTION BOARDS
46
A
91.2
839
5
375
321
C
B
PREWIRED DISTRIBUTION BOARD - SPN DOUBLE DOOR
Dimensions (in mm)
Ways Cat No.Sheet
Thickness
Dimensions Knock out holes
A B C Top BottomSide (Each
Side)
6 DSDMSHMDIW06000 1.6 276 176 296 4 4 2
8 DSDMSHMDIW08000 1.6 312 212 332 4 4 2
10 DSDMSHMDIW10000 1.6 348 248 368 4 4 2
12 DSDMSHMDIW12000 1.6 384 284 404 6 6 2
16 DSDMSHMDIW16000 1.6 456 356 476 8 8 2
RANGE
SPN DD – 6, 8, 10, 12 & 16W
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & IS: 8623
FEATURES
• Phase/Neutralterminalblockforterminationofincomingand outgoing wires
• ColoredflameretardantPolyamideterminalblocksandFRLS wiring for easy identification, Phases & Neutral
• AdetachablecassetteisprovidedforsaferemovalofMCB/RCCBfrom DB without loosening the internal cable connection of Phase & Neutral Circuit
• DBsareprovidedwithintegralloosewireboxinSPNfor accommodating extra bunch of wires
• IP42
DISTRIBUTION BOARDS
47
BA
431
482
C
497
763
PREWIRED DISTRIBUTION BOARD - TPN SINGLE DOOR
Dimensions (in mm)
Ways Cat No.Sheet
Thickness
Dimensions Knock out holes
A B C Top BottomSide (Each
Side)
4 DSDMTHMSIW04000 1.2 385 318 400 5 5 0
6 DSDMTHMSIW06000 1.2 423 353 437 7 7 0
8 DSDMTHMSIW08000 1.2 460 389 472 9 9 0
12 DSDMTHMSIW12000 1.2 605 534 618 13 13 0
RANGE
TPN SD – 4, 6, 8 & 12W
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & IS: 8623
FEATURES
• Phase/Neutralterminalblockforterminationofincomingandoutgoing wires
• ColoredflameretardantPolyamideterminalblocksandFRLSwiring for easy identification of R, Y & B Phases & Neutral
• AdetachablecassetteisprovidedforsaferemovalofMCB/RCCBfrom DB without loosening the internal cable connection of Phase & Neutral Circuit
• IP42
DISTRIBUTION BOARDS
48
Dimensions (in mm)
Ways Cat No.Sheet
Thickness
Dimensions Knock out holes
A B C Top BottomSide (Each
Side)
4 DSDMTHMDIW04000 1.2 389 315 410 5 5 0
6 DSDMTHMDIW06000 1.2 442 349 445 7 7 0
8 DSDMTHMDIW08000 1.2 460 387 482 9 9 0
12 DSDMTHMDIW12000 1.2 605 534 624 13 13 0
C
492
B
A
431
482
101
3
PREWIRED DISTRIBUTION BOARD - TPN DOUBLE DOOR
RANGE
TPN DD – 4, 6, 8 & 12W
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & IS: 8623
FEATURES
• Phase/Neutralterminalblockforterminationofincomingandoutgoing wires
• ColoredflameretardantPolyamideterminalblocksandFRLSwiring for easy identification of R, Y & B Phases & Neutral
• AdetachablecassetteisprovidedforsaferemovalofMCB/RCCBfrom DB without loosening the internal cable connection of Phase & Neutral Circuit
• DBsareprovidedwithintegralloosewireboxinTPNfor accommodating extra bunch of wires
• IP42
DISTRIBUTION BOARDS
49
Dimensions (in mm)
CONSUMER UNIT - IP 40 PROTECTION
Ways Cat No. Dimensions
A B C
4 DSDCSNHOSI04 139 89 154
8 DSDCSNHOSI08 211 161 226
12 DSDCSNHOSI12 283 233 298
6310
A
C
255
240
195
B
3
2487
RANGE
Automatic Phase Selector Unit
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & IS: 8623
FEATURES
• CanbeeasilyconnectedwithyourexistingDB
• AutomaticPhaseselection
• PhaselossProtection
• Undervoltage&overvoltageprotection
• Manualphasepriorityselection
• OperationalstatusindicationthroughLEDs
• ItcomeswithTPNMCBof63A
• IP42
DISTRIBUTION BOARDS
50
PER PHASE ISOLATION (PPI) HORIZONTAL DBs - IP 42 PROTECTION
RANGE
TPN – 4, 6 & 8W
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & IS: 8623
FEATURES
• DBswithphasesegregationandseparationbetweenincomerandoutgoing
• SuitableforFlushmountingandSurfacemounting
• With100Acopperbusbarforeachphase
• Withneutralbar,earthbarandcabletiesforcablemanagement
• Fullyinsulatedbusbar
• Withperphaseneutral&earthbar
• Suppliedwithwireset
• IP42
Knockout Holes (Ø31)
Dimensions (in mm)
96.5
11
A
B
C
3
422
400
345
Ways Cat No.Capacity of 17.8 mm Module
Incomer + Outgoing A B C Top Bottom SideSheet
Thickness
2+4 DSDPTHPDRW04 4 + (6+12) 323 268 341 6 6 2 1
2+6 DSDPTHPDRW06 4 + (6+18) 395 340 413 8 8 2 1
2+8 DSDPTHPDRW08 4 + (6+24) 534 479 552 11 11 2 1
DISTRIBUTION BOARDS
51
PER PHASE ISOLATION (PPI) VERTICAL DBs - IP 42 PROTECTION
RANGE
PPI Vertical DB - 4 Tier - 2+8 & 2+12W
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & IS: 8623
FEATURES
• DBswithphasesegregationandseparationbetweenincomer and outgoing
• SuitableforFlushmountingandSurfacemounting
• With125Acopperbusbarforeachphase
• Withneutralbar,earthbarandcabletiesforcablemanagement
• Fullyinsulatedbusbar
• Withperphaseneutral&earthbar
• Suppliedwithwireset
• IP42
AB
C 11103
3
740
750
665
Knockout Holes (Ø31)
Dimensions (in mm)
Ways Cat No.
Capacity of 17.8 mm Module Incomer +
Outgoing A B C Top Bottom SideSheet
Thickness
2 + 8 DSDPTVPDRW08 4 + (6+24) 323 248 338 7 7 6 1.2
2 + 12 DSDPTVPDRW12 4 + (6+36) 395 320 405 7 7 6 1.2
DISTRIBUTION BOARDS
52
PHASE SELECTOR DBS (Without Rotary Switches & Wires)
PHASE SELECTOR (HORIZONTAL) DBs - 4 QUADRANT DESIGN (With Rotary Switches & Wires)
Ways Rating Cat No. (DD) Horizontal
4 40A DSDSCHDRZ04040 with eight way incomer slot
4 63A DSDSCHDRZ04063 with eight way incomer slot
6 40A DSDSCHDRZ06040 with eight way incomer slot
6 63A DSDSCHDRZ06063 with eight way incomer slot
8 40A DSDSCHDRZ08040 with eight way incomer slot
8 63A DSDSCHDRZ08063 with eight way incomer slot
WaysRegal Grey
Cat No. (DD) A B C D E Sheet
Thickness
4 DSDSCHDRZ04000 478 373 496 430 355 1
6 DSDSCHDRZ06000 514 409 532 430 355 1
8 DSDSCHDRZ08000 550 445 568 430 355 1
Knockout Holes (Ø31)
Dimensions (in mm)
448
C
355
430
A
B12
83
RANGE
Phase Selector (Horizontal - 4 Quadrant) - 4, 6 & 8W
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & IS: 8623
FEATURES
• Withinbuilt3nos.of40A/63Aphaseselectorswitches and 3 nos piano switches
• SuitableforFlushmountingandSurfacemounting
• With100Acopperbusbarforeachphase
• Withneutralbar,earthbarandcabletiesforcablemanagement
• Fullyinsulatedbusbar
• Provisionfor8Wincomer,indicatorlightR,Y,B(FPMCB/Isolator/RCCB)
• Suppliedwithwireset
• IP42
DISTRIBUTION BOARDS
53
11 105
525
600
610
A
BC 3
Dimensions (in mm)
PHASE SELECTOR (VERTICAL) DBs DOUBLE DOOR
Ways Rating Cat No. (DD) Horizontal
4 40A DSDSNVDRZ04040
4 63 A DSDSNVDRZ04063
6 40 A DSDSNVDRZ06040
6 63 A DSDSNVDRZ06063
8 40 A DSDSNVDRZ08040
8 63 A DSDSNVDRZ08063
Ways
Capacity of17.8 mm module
Incoming+Outgoing Rating A B C
Knockout Holes
Top Bottom Each Side
Ø25 Ø20 Ø25 Ø20 Ø25
4 8+12 40A 333 323 248 9 8 9 8 3
4 8+12 63A 333 323 248 9 8 9 8 3
6 8+18 40A 405 395 320 9 8 9 8 3
6 8+18 63A 405 395 320 9 8 9 8 3
8 8+24 40A 405 395 320 9 8 9 8 3
8 8+24 63A 405 395 320 9 8 9 8 3
RANGE
Phase Selector (Vertical) – 4, 6 & 8W
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & IS: 8623
FEATURES
• Withinbuilt3nos.of63Aphaseselectorswitchesand3nos.
piano switches
• SuitableforFlushmountingandSurfacemounting
• With100Acopperbusbarforeachphase
• Withneutralbar,earthbarandcabletiesforcablemanagement
• Fullyinsulatedbusbarandneutralbar
• Provisionfor8Wincomer,indicatorlightR,Y,B(FPMCB/Isolator/RCCB)
• Suppliedwithwireset
DISTRIBUTION BOARDS
54
PHASE SELECTOR ENCLOSURE (VERTICAL)
RANGE
40A to 63A
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & 8623
FEATURES
• CompactDBswhichoccupyminimumspace
• PhaseselectorDBsprovideflexibilityinselectingandinterchanging the phases in case there is power outage in one particular phase
• Suitableforsurface&flushmounting
• Costeffectivesolution
• Suppliedwithrotaryswitches,dulywired
• Suitableforuseon240/415V,50Hzsupply
• IP40
Phase Selector Enclosure (Vertical) (with rotary switches, duly wired)
110
CBA
3
175
380
316
Knockout Holes (Ø31)
Dimensions (in mm)
Rating Cat. No. A B C Top BottomSheet
Thickness
40A DSDATVFS40 65 83 123 7 7 1.2
63A DSDATVFS63 91 109 144 7 7 1.2
DISTRIBUTION BOARDS
55
6W, 8W & 12W
D- 31 Knockout holes O/G
D- 31 Knockout holes O/G
659
625
485
B
A
C 2222
102
8
Dimensions (in mm)
7 SEGMENT DBs - IP 42 PROTECTION
RANGE
7 Segment DB - (TPN DD) - 4, 6, 8 & 12W
SPECIFICATION
IEC 61439 - 3 / IS: 13032 & IS: IS: 8623
FEATURES
• DBswithphasesegregationandseparationbetweenincomer and outgoings
• SuitableforFlushmountingandSurfacemounting
• With100Acopperbusbarforeachphase
• Withneutralbar,earthbar
• Fullyinsulatedbusbar
• MainIncomerFPIsolator&FPChangeover,DPRCCBas sub-incomer and SP MCBs as outgoing
• Suppliedwithwireset
• IP42
Ways Cat No. Sheet Thickness
Dimensions Knock out holes (Ø31)
A B C Top Bottom
4 DSDMTHDDRW04 1.2 440 380 474 7 7
6 DSDMTHDDRW06 1.2 548 488 582 8 8
8 DSDMTHDDRW08 1.2 656 596 690 10 10
12 DSDMTHDDRW12 1.2 872 812 906 13 13
DISTRIBUTION BOARDS
56
A
E
63
102 BD
10C
B C
A
MCB SHEET STEEL ENCLOSURES
MCB PLASTIC ENCLOSURES
Dimensions (in mm)
Dimensions (in mm)
Ways (amp.) Cat No.
1 DSDESSP
2 DSDESDP
3 DSDESTP
4 DSDESFP
Ways Cat No.
1/2 DSDEPDP
3/4 DSDEPFP
Ways Dimensions
A B C2 140 45 65
4 140 81 65
Ways
DimensionsKnock out holes
(Ø25)
Sheet ThicknessA B C D E Top Bottom
2 60 160 70 170 30 1 1 1
4 98 180 108 190 62 2 2 1
FEATURES
• Enclosureforindependentcutof/connectionofelectricalappliances
FEATURES
• Enclosureforindependentcutof/connectionofelectrical appliances
DISTRIBUTION BOARDS
57
Rating Description Cat No.
25A Sheet Metal DSDMCSN0251025
25A Plastic DSDTCSN0251025
Rating Description Cat No.
25A Sheet Metal DSDMCDP0251025
25A Plastic DSDTCDP0251025
MCB PROTECTED SOCKET (MODULAR AC BOX)
MCB protected socket is a new concept to provide safety for appliances which are plugged in to power sockets in residences as well as commercial premises. It provides inbuilt protection over current & short circuit with the help of MCB. It is designed for quick and easy installation and is new style statement for safety.
RANGE
25A
RATED VOLTAGE UN
25A
RATED FREQUENCY
50 Hz
TERMINAL CAPACITY
6 mm2
FEATURES
• Aestheticappeal
• Idealforlocalsectioning-Selectivity
• Highqualitycontactsensuresreliability
• BuiltinMCBsprotection,shortcircuitbreakingcapacity(3kA)
• SuitableforprotectionofhomeapplianceslikeACs,LCD, Geyser, Microwave etc.
MCB PROTECTED SOCKET (MODULAR AC BOX) 4 MODULE
MCB PROTECTED SOCKET (MODULAR AC BOX) 3 MODULE
DISTRIBUTION BOARDS
POWER SHIELD (MINI MCB WITH ENCLOSURE)
Rating Cat No.
32A DSMPCDPA032
RANGE
32A
RATED VOLTAGE UN
240V ac Rated Frequency : 50 Hz
TERMINAL CAPACITY
6 mm2
FEATURES
• Appealing&contemporaryaesthetics
• compact&spacesavingdesign
• Overload&shortcircuitprotection
• ProvenMCBmechanismforlongerlife
• Easytooperate&replace
• Completelyinsulateddesign
• Indicationofsupply
• InplasticenclosurewithminiMCB
MINI MCB WITH ENCLOSURE
58
Rating (Amp.) Cat No.
20A/SPN/DP (AC Box) DSDPUSN020
20A/TP DSDPUTN020
30A/TP DSDPUTN032
PLUG AND SOCKET ENCLOSURES
ACCESSORIES
• NeutralBar/EarthBar
• DINChannel
• BusBarwithPVCSleeve
• BlankingPlate1/2
CUSTOMIZED DBS
• PrewiredDB
• DBswithextendedloosewirebox
• MeterBox(1Phase&3Phase)
ROW TYPE DISTRIBUTION BOARDS
Row type distribution boards are versatile in design and aesthetics. These are specially designed for domestic as well as multi-storey complexes. Considering the capacity usage requirement, these are available in 1,2,3,4 and 5 rows both in 12 module and 16 module versions. The flush mounting and aesthetic look adds to the grace of interiors. These are supplied duly epoxy powder coated with shade RAL 7035 or as per specific requirement of the customers.
FEATURES
• TheDBcanbesuppliedwithneutralandearthbarsifsorequired
• TheenclosuresaremadeofspecialgradeCRCAsteelsheetmanufac-tured with latest CNC punch and brake presses to attain higher degree of perfection
• Adequatenumberofknockoutsattheendplatesareprovidedforeaseof wiring
• DinrailsareprovidedforsnapmountingofMCBs/RCCBs
• TheDBissuitableforIP40degreeofprotection
254.
0
(fixi
ng c
ente
r)
L
L
278.
011
0.0
152.
0
TP
SPN
63.0
63.0
56.0
Earth terminal
W
W
Dimensions (in mm)
Rating Code
Item Surface
Mounting Knock out Incoming
Amps. Outgoing
W L
20 KSPS/SP 133 162 1 No. ø 26 1 No. ø 26
20 KSPS/TP 123 287 1 No. ø 26 1 No. ø 26
30 KSPS/TP 123 287 1 No. ø 26 1 No. ø 26
Metal Clad Plug & Socket
59
Metal Clad Plug & Socket
Metal clad Plug & Socket are designed for heavy duty industrial applications so that better safety to installation & equipment can be provided. Suitable for humid and dusty / corrosive atmosphere, the metal clad and socket can be used for domestic, commercial and industrial applications.
• Fingerprotectionfromaccidentalcontactwithplugpinsbyprovisionof an over hang around the pins of the plug.
• Protectivecap/coverprovidedforsocketwhennotinuse.
• Contact tubes of socket deeply recessed to prevent finger contact.
• Provisionofscrapingearth.Theearthconnectionmakesfirst&breakslast.
• Visibleearthterminalforeaseofcheckingearthconnection.
• Rubbercableguardintheplugforprotectionofincomingflexiblecable.
• Differentcircuitscannotbeaccidentallyinterconnectedi.e.nonReversible.
FEATURES
3 Pin, 20A for single phase (2P + E) configuration 4 Pin, 20A & 30A for three phase (3P + E) configuration
Conforms to IEC : 60309-1 & 3
RANGE
SPECIFICATION
METAL CLAD PLUG & SOCKET
The outer casting are made of non-corroding die cast aluminium alloy. The interiors are moulded out of superior grade phenolic/polyester compound to lend better mechanical strength and electrical properties. Protective cap/cover for socket provides safety when socket not in use.
CONSTRUCTION
Contact tubes of socket are deeply recessed to prevent finger contact. An overhang around the pins of the plug provide finger protection from accidental contact. The earth connection makes first and breaks last. Rubber cable guard in the plug provides protection to incoming flexible cable.
60
Current Rating
Type No. of Pole Rated VoltageInsulation Voltage
Thermal RatingMax. HP for
Rated Voltage
Recommended MCB
Protection
20 A Plug Socket 2 + E 250 V 500 V 25 A 6.0 HP . 240 V 25 A 'C' Series
20 A Plug Socket 3 + E 500 V 660 V 25 A 12.5 HP . 415 V 25 A 'C' Series
30 A Plug Socket 3 + E 500 V 660 V 32 A 20.0 HP . 415 V 32 A 'C' Series
E
E
NL N
NN
L
E
E
LL
Plug2 Pole + E
Plug3 Pole + E
Socket2 Pole + E
Socket3 Pole + E
Note
• Wheremotorsarebeingstarted,theratingsofPlugs&Socketsshouldbeselectedontheabovebasis.• Forconstantloadapplications,thesePlugs&Socketscanbesafelyusedupto30%continuousoverloading
THREE PIN & FOUR PIN
Description Current Rating (A) Cat No.
Plug
2 Pole + Earth 20 A ISQPDP020
3 Pole + Earth 20 A ISQPTP020
3 Pole + Earth 30 A ISQPTP030
Socket
2 Pole + Earth 20 A ISQSDP020
3 Pole + Earth 20 A ISQSTP020
3 Pole + Earth 30 A ISQSTP030
Metal Clad Plug & Socket
61
DIMENSIONAL DETAILS (IN MM) - SOCKET
Bas
e di
amet
er
Inne
r di
amet
er
HeightDiameter offixing hole
Pitch circlediameter
Rating (A) A B C D(f) PCD
20 SP 67 50.3 37.5 4.5 59.8
20 TP 76 59 42 4.5 67.3
30 TP 83.5 67.5 55 4.5 76
DIMENSIONAL DETAILS (IN MM) - BOLTED TYPE FUSE LINKS - PLUG
Height of plug
Dia
. of p
lug
Rating (A) E F
20 SP 44.2 46
20 TP 47 51
30 TP 78 66
Metal Clad Plug & Socket
62
The letter X can be used in place of the f i rst or second digit to indicate that tests have e i ther not been made or are not appl icable.
Protected against strong jets of water e.g. for use on ship decks - l imited ingress permitted
Protected against low pressure jets of water from al l d i rect ions - l imited ingress permitted
Protected against after splash from al l d i rect ions - l imited ingress permitted
Protected against sprays of water up to 60° from the vert ica l
Protected against d i rect sprays of water up to 15° from the vert ica l
Protected against vert ica l ly fa l l ing drops of water e.g. condensat ion
No Protect ionNo Protect ion 0
1
2
3
4
5
6
0
1
2
3
4
5
6
Protected against sol id objects up to 50 mm. e.g. acc idental touch by hands
Protected against sol id objects up to 12 mm e.g. f ingers
Protected against sol id objects over 2.5 mm e.g. tools and wires
Protected against sol id objects over 1 mm e.g. tools , wires and smal l wires
Protected against dust - l imited ingress, no harmful deposits
Total ly protected against dust .
IP RATINGSThe IP (International Protection) rating given to an enclosure states the degree of protection it offers by means of two digits. A summary of these is shown below, for a more detaileddefition, see IEC 529 : 1989, BS EN 60529 : 1992.
FIRST DIGITProtection against solid foreign objects and access to hazardous parts.The first digit covers protection against penetration by solid objects, which includes hands and tools such as screwdrivers.
At the lowest of seven levels, 0, no protection is offered, either of the equipment itself from damage by intrusion or of a person contacting live or moving parts. At the highest, there shall be no entry of dust.
SECOND DIGITProtection against ingress of water. The second digit covers the degree of protection against the entry of water, on a progressive scale. for example, number 1 indicates that dripping water shall have no harmful effect, and number 6, that water projected in powerfuljets against the enclosure from any direction shall have no harmful effects.
TECHNICAL INFORMATION
CATEGORY OF DUTYThe category of duty defines the basic type of circuit and switching capability of the device, and selection should be made accordingly.
UTILISATION CATEGORY TYPICAL APPLICATIONSAC20/DC20 Connecting and disconnecting under no-load.
Assumes all switching operations are carried out by other capable devices before this device is operated.
AC21/DC21 Switching of resistive loads including moderate overloads.
Suitable for purely resistive type loads devices can switch 150% of its rated current under fault conditions
Ue = Rated Operat ional Voltage
The normal l ine-to- l ine voltage of the
system should not exceed (Ue)
Ui = Rated Insulat ion Voltage
The voltage on which the die lectr ic propert ies have convent ional ly been based us ing tests at h igh voltage and mains frequency. I t i s intended to replace this va lue with (Uimp)
Uimp = The voltage on which c learance distances are based.
The value of trans ient peak voltage the c i rcuit breaker can withstand from switching surges or l ight ing str ikes imposed on the supply.
e.g. Uimp = 8kV, Tested @8kV peak with
1.2/50m (ms)S impulse wave
In = Rated Current
The current which the c i rcuit breaker wi l l carry cont inuously under specif ied condit ions and on which the t ime / current character ist ics are based.
Unless otherwise s lated ( In) i s based on a reference ambient temperature of 30° cent igrade.
Icu Rated Ult imate Short Circuit
Breaking Capacity
The calculated prospect ive fault current at the incoming terminals of the c i rcuit breaker should not exceed ( Icu) .
Except ion: Us ing back-up protect ion as specif ied by the manufacturer.
Ics Rated Short-t ime Withstand Current
The maximum level of fault current operat ion after which further serv ice is assured without loss of performance.
Icw Rated Short-t ime Withstand Current
Circuit breakers of ut i l i sat ion category ‘B’ have a short-t ime delay a l lowing t ime-graded select iv i ty between c i rcuit breakers in ser ies.
( Icw) is the current the c i rcuit breaker wi l l withstand for the maximum short-t ime delay t ime. Preferred t imes are 0.05, 0.1, 0.25, 0.5 and 1.0 second.
Ui = 660V
Tested@
2500V ac 50Hz
AC22/DC22 Switching of mixed resistive / inductive loads, including moderate overloads.
Suitable for mixed resistive / inductive loads. Devices can switch 300% of its rated current under fault conditions.
AC23/DC23 SWITCHING OF HIGHLY INDUCTIVE LOADS. Devices complying with AC23/DC23 are provided mainly as back-up to other means of switching. e.g. contacts. In the event of failure of functional devices, an AC23 / DC23 type device can safety interrupt a stalled motor current. Where devices are the only means of controlling individual motors, they should comply with the requirements of appendix A of the standard. (IEC 60947-3)
ZSD
MC
0000
1/ J
AN
2015
/AU
G20
16
Havells India Ltd. Corp Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304 (U.P.), Ph. +91-120-3331000, E-mail: [email protected], www.sel.co.in Consumer Care No.: 1800 103 1313 , 1800 11 0303 (All Connections), 011-4166 0303 (Landline)
CIN - L31900DL1983PLC016304.
Regional & Branch Offices:
NORTH - REGIONAL OFFICE: Corporate Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304, Tel: 0120-3331000, Delhi: Tel: 011-47676700, 23888200, Chandigarh: Tel: 0172-4232400-401, Dehradun: Tel: 0135-6670202, Noida / Haryana: Tel: 0120-3331000, Ludhiana: Tel: 0161-4676000 / 24, Jammu: Tel: 0191-2478330, 2479330, Sri Nagar: Tel: 0194-2490431, Jaipur: Tel: 0141-3914645, 3988210 Jodhpur: Tel: 0291-9214201640 / 45, Lucknow: Tel: 0522-6672100, Kanpur: Tel: 0512-6710400, 6710409
EAST - REGIONAL OFFICE: Kolkata: ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata-700001, Tel: 033-40129851 / 52, Bhubaneshwar: Tel: 0674-6668101/102/103/104, Guwahati: Tel: 0361-2134521, 2458923, 2460355, Siliguri: Tel: 0353-2525907, Ranchi: 0651-2244861, 2244862, 2244864, 2244868, 2244869, Jamshedpur: Tel: 0657-6542492, 09234369436, Patna: Tel: 0612-2207221, 2207222, 2207223, 2655518
WEST - REGIONAL OFFICE: Mumbai: Mumbai: 1271, Solitaire Corporate Park, Bldg. No. 12, 7th Floor, Andheri - Ghatkopar Link Road, Chakala, Andheri (East), Mumbai- 400093. Ph.: 022 - 67298600-602, Ahmedabad: Tel: 079-40061111, 40060738-740, Indore: Tel: 0731-2572340-41, 4009998 (Airtel), Rajkot: Tel: 0281-2481112, 2921212, Nagpur: Tel: 0712-2240932, 2242692, 2242699 Pune: Tel: 020-64016413 / 14, Raipur: Tel: 0771-4243400 / 01, Surat: Tel: 0261-2350137, 9979890137, Jabalpur: Tel: 0761-4064491
SOUTH - REGIONAL OFFICE: Chennai: Sigapi Achi Building, No. 18 / 3, 6th Floor, Rukmani Lakshmipathy Road, Egmore, Chennai-600008, Tel: 044-42280600, 605, Bangalore: Tel: 080-49075000, Coimbatore: Tel: 0422-2305767, 2306199, 2305199, Hyderabad: Tel: 040-27533372, 27533355, 27533632, 66320407/0408/6401/6402, Kochi: Tel: 0484-4099000, Vishakapatnam: Tel: 0891-6514339, Vizag: Tel: 0891-6514339, Vijayawada: Tel: 91+9247058847/57, Calicut: 09895855499, Madurai: 09994493242, Trivandrum: 09633817795, Hubli: 0836-4248600, Trichy: 09944460160
Representative Offices: • Goa • Solapur • Gwalior • Kathmandu • Bhopal