thermal & acoustical - international · pdf filethermal & acoustical spray-applied...

8
THERMAL & ACOUSTICAL SPRAY-APPLIED FINISHES 07 20 00 07 21 23 07 21 29 09 83 16 ® ® ® ®

Upload: phamthu

Post on 14-Feb-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

THERMAL & ACOUSTICALSPRAY-APPLIED FINISHES

07 20 0007 21 2307 21 2909 83 16

® ®

®

®

The Custom Spray SystemK-13 insulation is a thermal and acoustical commercial cellulose insulation typically used as an exposed ceiling finish requir ing no additional materials. K-13 meets project requirements for insulation (R-value), noise reduction (NRC), condensation control, texture, and color. Additionally, K-13 usually provides these features at lower installed prices than many common alternatives.

A Total System: Fiber, Binder, ApplicationK-13 i s a total system of recycled natural f ibers, chemical treatment, binding system, and application method. The K-13 system begins in a strict quality-controlled manufacturing process using specially prepared cellulose f ibers that are chemically treated to add resistance to fire, mold, and mildew.

K-13 is then applied by an international network of l icensed applicators through approved fiber machines and nozzles for control of the fiber/binder ratio. During application, the K-13 fibers combine with a patented water-based adhesive. This unique adhesive adheres to virtually any properly prepared substrate and standard material such as metal, wood, concrete, or glass. The finished product is a strong, durable monolithic coating of a predetermined thickness.

Naturally Tough – Naturally AttractiveAvailable in a variety of colors, K-13 is an ideal surface finish in both new construction and renovation projects.

K-13 is avai lable in seven standard colors and can also be specified in specially matched custom colors. Please contact us for more information on customizing your K-13 application.

Black Gray Lt. Gray White Beige Tan CocoaColor selection will affect the final price.

Thermal PerformanceK-13 insulates by creating dead air spaces between and within its hollow fibers. Because K-13 fibers are sprayed-in-place, the mater ial f i l ls cracks, seams, and voids, forming a monolithic coat ing over the subst rate reducing ai r inf i l t rat ion. Unl ike prefabricated insulations, K-13 has no voids or compressed areas to reduce thermal efficiency. The result is a more effective in-place product with exceptionally low heat transfer characteristics and an R-value of 3.7 per inch.

The patented adhesive util ized in the installation of K-13 provides unequaled strength allowing applications from ¾” up to 5” thick without mechanical support. For an even higher R-value, we recommend the K-13 High-R System, a mechanically supported system for R-values exceeding R-19. For more information about the advantages of the K-13 High-R System, please visit www.spray-on.com/info/highr.

Condensation ControlFor areas such as indoor pools and ice arenas, K-13 aids in condensation control. The proper combination of K-13 and ventilation prevents condensation on metal, concrete and other surfaces. K-13 reduces ventilation requirements, saving in both the ventilation equipment investment operating costs.

CSI 07 21 29

EnvironmentalWe manufacture our finishes from 80% recycled material and may contribute to satisfying credits under the LEED® green building program. Additionally, our low emission adhesive provides superior bond strength without compromising indoor air quality. As a UL GREENGUARD Gold Certified product, K-13 complies and surpasses emission standards set by the California Department of Public Health (CDPH) / CA Section 01350, Collaborative for High-Performance Schools (CHPS). K-13 does not contain silica.

Acoustical PerformanceThe res i l ient f ibers of K-13 absorb sound energy instead of reflecting it, reducing reverberation and excessive noise often present in modern design, greatly improving ambient sound quality and intell igibil ity.

K-13 Sprayed Thermal and Acoustical Insulation on Solid Backing | ASTM C-423

Inches 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC

.625” 0.05 0.16 0.44 0.79 0.90 0.91 0.55

1” 0.11 0.32 0.84 0.99 1.01 0.98 0.80

1.75” 0.19 0.60 1.05 1.11 1.03 0.98 0.95

2” 0.47 0.90 1.06 1.06 1.08 1.07 1.00

3” 0.57 0.99 1.04 1.03 1.00 0.98 1.00

K-13 Sprayed Thermal and Acoustical Insulation Applied on 1.5” Metal Deck

Inches 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC

1.5” 0.36 0.89 1.26 1.07 1.01 1.00 1.05

3” 0.97 1.04 1.13 0.99 0.95 0.98 1.05

K-13 Sprayed Thermal and Acoustical Insulation Applied on 2” Metal Deck

Inches 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC

1” 0.39 0.63 0.96 0.99 1.04 1.06 0.90

2” 0.55 0.99 1.13 1.06 1.05 1.10 1.05

K-13 Sprayed Thermal and Acoustical Insulation Applied on 3” Metal Deck

Inches 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC

1.5” 0.55 0.92 1.11 1.02 0.95 0.99 1.00

2.75” 0.69 0.98 1.17 1.03 0.97 1.04 1.05

Sound ResultsK-13 Applied at 3” to Recording Studio (Field Test)

SE

CO

ND

S

5

4

3

2

1

0125 Hz 500 Hz 600 Hz 1000 Hz 2000 Hz 4000 Hz

K-13 Applied at 1” to Ceiling in Indoor Pool (Field Test)

SE

CO

ND

S

10

8

6

4

2

0250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz

1

BEFORE

BEFORE

AFTER

AFTER

K-13 is versatile. Typical projects include: Parking Garages, Classrooms, Restaurants, Museums, Warehouses, Airports, Stadiums, Worship Facilities, Open Offices, Auditoriums, Convention Centers, and more.

Fire Performance RatingsK-13 has been rated and approved by Factory Mutual Research Corporation for use in the following categories:

• Category I: As an interior finish material of low fire hazard (Class I Building Material) over noncombustible surfaces not requir ing automatic sprinkler protection in and of itself.

• Category II: As a protective coating to delay the ignition and reduce the surface burning rate of combustible wood and cellulosic fiber building materials.

• Category III: As a protective coating to delay the ignition and reduce the surface burning rate of low melting, combustible cel lu la r p last ic bui ld ing mater ia l s and to protect thei r dimensional stability for a brief period.

• Category IV: As a protective coating for building structural steel to supplement automatic sprinkler protection in preventing structural failure temperatures of the steel in high fire hazard occupancies.

• Category V: As a protective coating to the underside of Class II insulated steel roof deck construction to sufficiently lower the rate of fuel contribution from the Class I I deck components to qualify the construction as Class I allowing automatic sprinkler protection to be omitted where permissible under Factory Mutual Standards.

These f i re rat ings are der ived from product tests per ASTM standards and are used solely to measure and describe properties of materials and products in response to heat and flame under controlled laboratory conditions. They are not intended to reflect hazards presented by these or any other materials under actual fire conditions.

Surface Burning CharacteristicsK-13 has a Class 1, Class A flame spread rating per ASTM E-84, UL-723, NFPA-255 and UBC-42.Flame spread- 5 Smoke developed- 5 Underwriters’ Laboratories – Ref. #R5499

ASTM Standards ComplianceASTM C 518 Thermal ConductivityASTM E 84 Surface Burning CharacteristicsASTM C 423 Noise Reduction CoefficientsASTM D 2244 Light ReflectanceASTM E 736 Bond StrengthASTM E 859 Air ErosionASTM C 739 Moisture AbsorptionASTM E 90 Sound Transmission LossASTM E 1042 Acoustical AbsorptionASTM C 1149 Spray-Applied Cellulose Insulation

Test reports available upon request.

Miscellaneous Approvals & SpecificationsUnderwriters Laboratories Classified Code Compliance Report UL ER 5499

Factory Mutual Research – Report Nos. 19678, 20399, & 24703

Federal Defense Logistics Agency Cage Code: ONJU2

Corps of Engineers Guide Specifications – CE-201.01

Department of the Navy Guide Specifications – NFGS-07218

EPA 40 CFR Part 248

Miami-Dade county, FL. NOA #18-0122.09 - Expires Sept. 4, 2020

Meets California Bureau of Home Furnishings Standards

Resource Conservation and Recovery Act

Federal Specification – SS-S-111C

Los Angeles – RR-24311

New York – MEA 65-96-M

2

Product DescriptionSonaSpray “fc” is a spray-applied acoustical texture designed for a wide range of project types. SonaSpray “fc” provides an attractive, high-performance solution to acoustical and lighting design objectives in both new construction and renovation p ro jects . Typ ica l ins ta l lat ions inc lude schoo l s , chu rches, auditoriums, passenger terminals, l ibraries, detention facilities, cafeterias, offices, hotels, and condominiums.

SonaSpray “fc” is available in White, Arctic White, Black, and specially matched colors.

Acoustical PerformanceAs tested by an NVLAP accredited acoustical laboratory per ASTM C-423, SonaSpray “fc” provides an exceptionally high noise reduction coefficient (NRC). A typical installation of 1/2” thick on solid backing has an unequaled NRC of .65.

SonaSpray “fc” on Solid Backing | ASTM C 423Inches 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC

.5” 0.00 0.14 0.49 0.87 1.00 0.99 0.65.75” 0.10 0.23 0.70 0.98 1.01 0.96 0.751” 0.05 0.40 0.94 1.04 0.97 0.99 0.85

SonaSpray “fc” on 1.5” Metal Deck | ASTM C 423Inches 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC

.75” 0.17 0.58 0.91 0.89 0.87 0.84 0.80

Substrate CompatibilitySonaSpray “fc” conforms to any surface configuration such as barrel vaults, concrete “T”, corrugated decks, pan construction and other complex surfaces. The high-performance adhesive bonds to virtually all construction materials including gypsum board, plaster, wood, metal, and concrete. Some sur faces (water-stained cei l ings, wood, and oxidized metal) requi re sealing to prevent migratory staining of the SonaSpray “fc”.

Durability and MaintenanceThe strong, resilient bond of the adhesive used to apply SonaSpray “fc” provides a remarkably durable surface. SonaSpray “fc” resists impact and abrasion without the cracking or spalling typical of many cementitious or plaster-based materials.

In areas where even higher abrasion resistance may be desirable, SonaSpray “fc” Dura-K is specified. This product provides even greater bond and compressive strength without reducing the acoustical performance.

ASTM Standards ComplianceFlame Spread Index 5 ASTM E 84/UL 723Smoke Developed 5 ASTM E 84/UL 723Bond Strength

SonaSpray “fc” >600 psf ASTM E 736SonaSpray “fc” Dura-K >900 psf ASTM E 736

Compression StrengthSonaSpray “fc” >400 psf ASTM E 761SonaSpray “fc” Dura-K >600 psf ASTM E 761

CSI 09 83 16

4

CSI 07 20 00

5

System DescriptionUUre-K is a 15-Minute thermal barrier approved to go over polyurethane foam. Foam insulation systems are developed from polyurethane and polyisocyanurate. If foam is left exposed on the interior of a building, it can create a life threatening possibil ity in the event of a fire.

Ure-K 15-Minute Thermal Barrier is spray-applied over exposed applications of polyurethane foam in existing buildings and new construction projects as a combination system to meet mandatory code requirements.

Installation & EnvironmentalUre-K fibers and a low-emissions patented adhesive are applied to foam applications through equipment engineered to control the adhesive/fiber mixture. The Ure-K adhesive provides superior adhesion to all types of foam insulations without compromising indoor air quality.

Ure-K is manufactured from 80% recycled materials and may contribute to satisfying credits under the LEED® green building program. Ure-K is a UL GREENGUARD Gold Certif ied product.

Thermal BarrierUre-K is tested and approved as a 15-minute thermal barrier over foam. Ure-K covers interior applications to maintain a sufficiently low surface temperature for a minimum of 15-minutes to prevent ignition and the rapid spread of fire. The average installed thickness of Ure-K is 1.25”.

Thermal InsulatorThe combination of Ure-K and polyurethane has the highest efficiency of all available insulations. Ure-K is specified at 1.25” adding R-4.5 to the overall insulation package.

Noise ReductionUre-K reduces reverberation and excessive noise improving sound quality and overall intell igibil ity. This is an important benefit in controll ing noise levels to meet OSHA and other requirements.

Ure-K over Closed-Cell Polyurethane Foam | ASTM C 423

Inches 125 Hz 250 Hz 500 Hz 1,000Hz 2,000 Hz 4,000 Hz NRC

1.25” 0.38 0.57 1.00 1.07 1.06 1.07 0.95

Typical Applications• Restaurants/ Bars• Freezers/ Coolers• Refrigerated Warehouses• Curtin Wall High-Rise Buildings• Tilt-up, Pre-cast, & Poured-in-place Concrete Construction• Underground Parking Decks• Metal Buildings• Projects requir ing a high R-Value• Projects concerned with Energy Efficiency

TestingUre-K has been tested according to NFPA 275 Part 1 & Part 2 and is approved to be used as a 15-Minute Thermal Barrier over Polyurethane Foam.

NFPA 275 - Part 1 & 2

ASTM E 119 (UBC 26-2) Full-Scale Fire Wall Test: Passed

NFPA 286 (Testing over 2 pound and 0.5 pound foam)

ASTM E 84 - Class 1 Class A RatedFlame Spread 5Smoke Development 5

Thermocouple Data

Deg

rees

(F)

500

450

400

350

300

250

200

150

100

50

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15Time (Minutes)

Min Max TC LimitMax Avg TC LimitAvg

CSI 07 21 23

System DescriptionCelbar is a blend of specially prepared cellulose fibers, organic in nature, treated with adhesive and fire-resistant chemicals. When sprayed in place, the interlocking fibers result in a mass that produces excellent sound and thermal properties.

Celbar i s pneumat ica l ly sp ray- appl ied in wal l and f loor/cei l ing cavit ies to form a monol ith ic coating. This process seals cracks and holes in the wallboard, around plumbing and electrical outlets, vent ducts, and other ir regularities. There are no compressed areas or voids to al low sound leaks, R-value reductions, or air infi ltration.

Performance Where It CountsCelbar provides superior sound transfer control demanded by building designers, owners, and occupants. Celbar assemblies perform closer to lab-tested STC ratings in the field than other convent ional batt and soundboard systems. Th i s super io r per formance is due to the complete coverage and seal ing action of Celbar.

Laboratory tests have proven that Celbar produces significantly higher STC values than other identically constructed wall systems.

Typical StructuresHomes Hotels/Motels TheatersCondominiums Apartments RestaurantsTownhouses Shopping Malls Office Buildings

Physical PropertiesThermal PropertiesThickness 1.0” 2.5” 3.5”

R-value 3.8 9.5 13.3

Fire Hazard ClassificationUnderwriters Laboratories;Reference #R-5499

Listings• HUD-FHA-VA-Permits the use of Celbar in projects they finance

based on Celbar’s compliance with UMB-80.

ASTM E-119 Fire Rating - One HourCelbar has been tested in accordance with ASTM E-119 including hose stream test and is accepted for use in f i re- rated wal l assemblies as a one-hour wall.

Metal Stud AssembliesSTC Construction Detail

6024” OC, 4” Metal Studs, Two layers 5/8” Gypsum Board each side, Resil ient Furr ing one side, 3-1/2” Cellulose Spray• Test TL-94-024

5124” OC, 6” Metal Studs, One layer 5/8” Gypsum Board each side, 6” Cellulose Spray• Test TL-93-298

Wood Stud AssembliesSTC Construction Detail

5416” OC, 6” Plate, 2x4” Staggered Wood Studs, Two layer 5/8” Gypsum Board one side, One layer Gypsum Board other side, 5-1/2” Cellulose Spray• Test TL-93-232

5716” OC, 2x6” Wood Studs, Two layer 5/8” Gypsum Board each side, Resil ient Furr ing one side, 5-1/2” Cellulose Spray• Test TL-93-108

6216” OC, 6” Plate, 2x4” Staggered Wood Studs, Two layer 5/8” Gypsum Board each side, Resilient Furring one side, 5-1/2” Cellulose Spray• Test TL-93-236

Celbar RLCelbar RL, or Celbar Fire and Sound, is a system with one, two, and three-hour UL rated Firewall Assemblies. One of the most outstanding features is the record-setting weight load design at 1,415 pounds per stud. These wall assemblies can be constructed using 2x4 inch or 2x6 inch wood studs. We are proudest of the sound test results that these three assemblies received with an STC of 56 with one layer of gypsum board on each side, to the highest tested STC of 64.

Architects, contractors, and code officials will f ind this system affordable, able to meet and exceed all code requirements for fire and sound control, and easy to install. We have hundreds of applicators worldwide that have been trained to install our products.

6

12315 Robin Blvd. Houston, TX 77045

(713) 433-6701 • (800) 444-1252FAX: (713) 433-2029 [email protected]

Product LimitationsK-13, SonaSpray “fc”, and Celbar Spray should not be used in areas where there is prolonged exposure to heat in excess of 150°F (65°C). Nor should they be applied in areas requir ing a washable surface, or where combustible contaminants such as dust, oil, etc., exist. Accumulations of combustible contaminants may become hazardous as these contaminants will provide a fuel source that will burn when ignited and fire may spread. Celbar is applied with water and should not be sprayed on laminated wood paneling as it could cause warping. Celbar should not be used in areas where vinyl or foil wall covering or other vapor barriers are used on both sides of the wallboard,unless Celbar is allowed to dry completely before closing up the wall. Surfaces receiving K-13 and SonaSpray “fc” should be checked for poss ible contaminants, i .e., rust, d i r t, water stains, etc. prior to application. These areas should be sealed to prevent discoloration from surface contamination bleed through. For further information on limitations and precautions refer to ICC Technical Bulletin 001.

©2018 by International Cellulose CorporationK-13, SonaSpray “fc”, SonaKrete, Ure-K, and Celbar are manufactured from recycled fibers. 05/18

WarrantyInternational Cellulose Corporation (ICC) warrants its products to be free from defects in materials and workmanship at the time of shipment. Application warranties are provided by the install ing contractor. It is the responsibil ity of the user to determine compliance of the product with local building codes and other regulatory bodies. ICC is herein publishing information and data based on specific and generic tests. ICC believes this data is as reliable as the present state of the art in fire, thermal, and acoustical testing, and can be used only as a guide for design. ICC is not responsible for building design, appearance, or workmanship and makes no guarantee of performance. ICC specifically disclaims any warranty of merchantabil ity or fitness for a particular purpose. In no event shall ICC be liable for special, indirect or consequential damage.