thermal equivalent circuit for a transistor. junction temperature case temperatureheat sink...

25
Thermal Equivalent Circuit for a Transistor

Post on 15-Jan-2016

250 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Thermal Equivalent Circuit for a Transistor

Page 2: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Junction Temperature

Case Temperature Heat Sink Temperature

Ambient Temperature

Page 3: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Thermal Resistance from Junction to Case

Thermal Resistance from Case to Heat Sink

Thermal Resistance from Heat Sink to Ambient

Total Average Power Loss

Page 4: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

( )

C J T J C

S C T CS

A S T SA

J A T J C CS SA

T T P R

T T P R

T T P R

T T P R R R

Page 5: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Motorola MS-10 Heat Sink

Page 6: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Performance Under Forced Air Flow

Page 7: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Thermal Characteristic in Free Air

Page 8: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Top View of MS-10 Heat Sink

Page 9: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Hole Pattern for a TO-3 Case

Page 10: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Mica Insulator

Page 11: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Thermal Resistances for Mica Insulators

Page 12: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature
Page 13: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Clip-On Heat Sinks

Page 14: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Thermal Performance

Page 15: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Thermal Resistance for Clip-On

Page 16: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Bond-On Extrusions for DIP Packages

Page 17: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Thermal Performance

Page 18: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Thermal Resistances for Bond-On

Page 19: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Example

• TO-220 case style dissipating 5 watts

• RJC = 3.0 C / Watt (from device spec)

• TJmax = 150 C

• TAmax = 50 C

• Find the proper heat sink to keep the junction temperature from exceeding 150C in natural convection.

Page 20: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Need to determine a value for RCS – depends on the mounting technique.

If the device is mounted without an insulator, but only with Thermalcote, (silicone grease), check page 57, Figure 9 for TO -220 case style.

( )

J A

D

J C CS SA

J A

SA J C CS

D

T TP

R R RT T

R R RP

Page 21: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

RCS = 1 C/W

No Insulator

Use Thermalcote

Page 22: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

( )

(150 50 )(3 1)

5

16

J A

SA J C CS

D

SA

SA

T TR R R

P

C CR

W WC

RW

Page 23: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Thermalloy P/N 6030

Temperature rise above ambient@ 5 Watts Power Dissipation = 66 C

Page 24: Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature

Thermal Resistance RSA

6613.2

5SA

C CR

W W

As long as RSA is less than 16 C/W, the requirement is met.