© Copyright Report Systems Australia Pty Ltd. This document is partly based on Standards Australia Ltd copyrighted material that is distributed by SAI Global Ltd on Standards Australia Ltd’s behalf. It may be reproduced and modified in accordance with the terms of SAI Global Ld’s Licence 1210-c029 to Report Systems Australia (‘the Licensee’). This is a visual only Building Inspection & Report carried out in accordance with AS4349.1 Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample St Upper sample 4122 SERVICES New Construction Slab Frame Lock-Up Handover 6 Months Warranty ALLINSPECT PO BOX 1104 Park Ridge QLD Licence 15012225 1300254677 ABN 66160880642 Pre-Purchase Pre-Sale Commercial Rental Safety Reports Maintenance Reports Renovation Reports

Upload: others

Post on 14-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

© Copyright Report Systems Australia Pty Ltd. This document is partly based on Standards Australia Ltd copyrighted material that is distributed by SAI Global Ltd on Standards Australia Ltd’s behalf. It may be reproduced and modified in accordance with the terms of SAI Global Ld’s Licence 1210-c029 to Report Systems Australia (‘the Licensee’).

This is a visual only Building Inspection & Report carried out in accordance with AS4349.1

Pre-Purchase REPORT (hereinafter called the “Report”)

Inspection Date: 21/01/2020

Property Address: A15 Sample St Upper sample 4122

SERVICES

New Construction

Slab

Frame

Lock-Up

Handover

6 Months Warranty

ALLINSPECT

PO BOX 1104

Park Ridge QLD

Licence 15012225

1300254677

ABN 66160880642

Pre-Purchase

Pre-Sale

Commercial

Rental Safety Reports

Maintenance Reports

Renovation Reports

Page 2: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 2 of 26

ALLINSPECT 1300254677 Page 2

Brisbane, Gold Coast, Ipswich

Contents

Special conditions or instructions

The parties

Section A Results of inspection - summary

Section B General

Section C Accessibility

Section D Condition Report Defects

1. Safety Defects

2. Major Defects

3. Minor Defects

Section E Conclusion

Section F Important note

Section G Additional comments

Section H Certification

If you have any queries with this report or require further information, please do not hesitate to contact the person who carried out the inspection.

Page 3: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 3 of 26

ALLINSPECT 1300254677 Page 3

Brisbane, Gold Coast, Ipswich

Special conditions or instructions

The following apply: This is a Sample report, some things maybe different in other reports.

The parties

Report number: Sample _________________________________ ______________________________________________________

Pre-engagement inspection was emailed. agreement number (if applicable):

_________________________________ ______________________________________________________

Name of Client: Mr Sample

_________________________________ ______________________________________________________

Name of Principal (if applicable): N/A

_________________________________ ______________________________________________________

Address of Client: Same as Above

_________________________________ ______________________________________________________

Client’s email: [email protected]

_________________________________ ______________________________________________________

Client’s telephone number: Sample

_________________________________ ______________________________________________________

Consultant’s name: David Tacon

_________________________________ ______________________________________________________

Consultant’s licence number 535928 (if applicable):

_________________________________ ______________________________________________________

Consultant’s mobile number: 0421235310

_________________________________ ______________________________________________________

Company name: ALLINSPECT 15012225

_________________________________ ______________________________________________________

Company address and postcode: PO BOX 1104 Park Ridge 4125

_________________________________ ______________________________________________________

Company email: [email protected]

_________________________________ ______________________________________________________

Company telephone number: 32970345 1300 25 46 77

_________________________________ ______________________________________________________

Page 4: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 4 of 26

ALLINSPECT 1300254677 Page 4

Brisbane, Gold Coast, Ipswich

Section A Results of inspection - summary

This Summary is not the Report. The following Report MUST be read in full in conjunction with this Summary. If there is a discrepancy between the information provided in this Summary and that contained within the body of the Report, the information in the body of the Report shall override this Summary.

In respect of significant items:

Evidence of Serious Safety Hazards was observed - see Section D, Items D1.

Evidence of Major Defects was observed - see Section D, Items D2.

Evidence of Minor Defects was observed - see Section D, Items D3

Strata or company title properties

Not applicable.

Page 5: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 5 of 26

ALLINSPECT 1300254677 Page 5

Brisbane, Gold Coast, Ipswich

General description of the property

________________________________ ______________________________________________________

Residential building type: Detached house.

_________________________________ ______________________________________________________

Number of storeys: Single storey.

_________________________________ ______________________________________________________

Building age (approx): The building 1950+

_________________________________ ______________________________________________________

Smoke detectors: There were Smoke detectors and Safety Switch

Safety Switch: IMPORTANT NOTE The adequacy and testing of smoke detectors and safety switch is outside the scope of this standard inspection and report. Accordingly, it is strongly recommended that a further inspection be undertaken by a suitably qualified person.

_________________________________ ______________________________________________________

Site drainage: The site appears to be adequately drained. _________________________________ ______________________________________________________

Occupancy status: Occupied and fully furnished.

_________________________________ ______________________________________________________

Orientation (to establish the way the The façade of the building faces east. property was viewed): Note. For the purpose of this report the façade of the building

contains the main entrance door. _________________________________ ______________________________________________________

Prevailing weather conditions at the Dry. Fine time of inspection: _________________________________ ______________________________________________________

Other: Asbestos

_________________________________ ______________________________________________________

Primary method of construction

________________________________ ______________________________________________________

Main building – floor construction: Part suspended timber framed and slab-on-ground.

_________________________________ ______________________________________________________

Main building – wall construction: Timber framed. Cladded and Render, Brick Veneer.

_________________________________ ______________________________________________________

Main building – roof construction: Timber framed. Tiles

_________________________________ ______________________________________________________

Overall quality of construction Acceptable. and materials for building: _________________________________ ______________________________________________________

Overall quality of construction Acceptable. and materials for other structures _________________________________ ______________________________________________________

Level of maintenance: Poorly maintained.

Page 6: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 6 of 26

ALLINSPECT 1300254677 Page 6

Brisbane, Gold Coast, Ipswich

Section D Condition Report

The following items and matters were reported on in accordance with the Scope of Inspection. For building elements not identified in this Condition Report, monitoring and normal maintenance must be carried out (see also Section F ‘Important note’). The Client acknowledges that, unless stated otherwise, the Client as a matter of urgency should implement any recommendation or advice given in this Report.

D1: Serious safety hazards

Where it is: Internal What it is: Windows have no restrictors, this is a safety hazard. Results: At the time of inspection some of the windows do not have the restrictors on them. These items are a potential safety hazard and needs to be addressed. A window opening must be provided with protection, if the floor below the window in a bedroom is 2 m or more above the surface beneath. The above recommendations should be implemented straight away as a matter of urgency.

Page 7: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 7 of 26

ALLINSPECT 1300254677 Page 7

Brisbane, Gold Coast, Ipswich

Where it is: External What it is: Pool gate - not latching correctly. Results: The pool gate should automatically close to comply with Australian Standards and relevant state based legislation. Commenting on compliance with Legislation and Local Laws is outside the scope of this Report so this defect is noted for your information advice and further action. Maintenance of the pool gate and its fixings is urgently required. It represents an urgent and serious safety hazard if left unattended. Recommend a pool certifier to determine the method and the extent of any remedial work required and costs.

____________________________________________________________________________

Where it is: Internal What it is: Cooktop cracked, this is a safety hazard. Results: Damage occurs generally when building elements have either aged or decayed or as a result of impact damage (accidental or deliberate). Recommend an Electrician to further investigate. The above recommendations should be implemented straight away as a matter of urgency.

_____________________________________________________________________

Where it is: External What it is: Conduit damaged, this is a safety hazard. Results: The conduit in this area was found to be deteriorating at the time of inspection. Reporting on electrical is outside of the scope of this report so this is noted for further investigation from a competent person. Recommend an Electrician to further investigate. The above recommendations should be implemented straight away as a matter of urgency.

Page 8: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 8 of 26

ALLINSPECT 1300254677 Page 8

Brisbane, Gold Coast, Ipswich

____________________________________________________________________________

Where it is: Internal What it is: Smoke detector appears to be disconnected Results: This is a safety requirement. The adequacy and testing of fire safety equipment is outside the scope of this standard inspection and report. It is strongly recommended that a further inspection be undertaken by a suitably qualified person.

____________________________________________________________________________

Page 9: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 9 of 26

ALLINSPECT 1300254677 Page 9

Brisbane, Gold Coast, Ipswich

D2: Major defects

D2.1 Roof

Where it is: External Roof What it is: Cracked/Broken Tiles. Results: Broken or cracked tiles are the result of aging and the weather as well. If left (Not repaired or replaced) the broken/cracked tiles may allow water to enter into the roof void causing damage to the ceiling lining and may cause damage to the roof structure, which can lead to conditions that are conducive to structural damage. Recommend a roof contractor to further investigate and repair the roof as soon as possible. The above recommendations should be implemented as soon as possible.

___________________________________________________________________________

Page 10: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 10 of 26

ALLINSPECT 1300254677 Page 10

Brisbane, Gold Coast, Ipswich

D2.2 Subfloor space

Where it is: Subfloor entry & garage back wall. What it is: Termite damage subfloor and live or a nest of termites or high moisture with thermal. Results: Although no evidence of live termite activity was found in the area at the time of inspection it is suspected that termites was identified on the property. Further inspection of external and internal areas may be required in order to correctly identify the damage by termites and may include works of an intrusive nature. It is strongly recommended that a Licensed Builder ascertain the structural integrity and the extent of the unknown damage that may be concealed. It is also recommended that a Licensed Pest Company advise the treatment or method that should be carried out. The above recommendations should be implemented as soon as possible.

____________________________________________________________________________

Page 11: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 11 of 26

ALLINSPECT 1300254677 Page 11

Brisbane, Gold Coast, Ipswich

D2.3 Roof Void

Where it is: Roof Void What it is: Water leak – active Results: As the surrounding area was found to be damp at the time of inspection the leak is ongoing and requires urgent action. If left, not repaired it can cause damage to the ceiling lining and may cause damage to the roof structure, which can lead to conditions that are conducive to structural damage. Recommend a roof contractor to further investigate the leak and repair the roof as soon as possible. The above recommendations should be implemented as soon as possible.

____________________________________________________________________________

Page 12: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 12 of 26

ALLINSPECT 1300254677 Page 12

Brisbane, Gold Coast, Ipswich

Where it is: Garage What it is: Ceiling –Sagging Results: Sagging to the ceiling generally indicates that the building materials have swollen due to contact with water or that fixings, nails, or glue have become loose and require reattachment. In some cases, sagging ceiling linings may also indicate that there are structural issues causing surfaces to warp twist or sag. Where sagging appears to be major appointment of a structural engineer is advised to further inspect the property. A Licensed Tradesmen is recommended to determine the method and the extent of any remedial work required, and associated costs and the extent of the damage behind the ceiling cover.

____________________________________________________________________________

Page 13: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 13 of 26

ALLINSPECT 1300254677 Page 13

Brisbane, Gold Coast, Ipswich

D2.4 External

Where it is: External What it is: Under cover area is loose and potentially could collapse. Results: The primary structures are showing signs of deterioration as a results of damp conditions (wood rot) and rusty bolts which has created the loss of strength, which may cause the structure to fail and collapse. A Licensed Builder is recommended to determine the method, cost and the extent of any remedial work required and to determine the structural integrity of the structure. The above recommendations should be implemented as soon as possible as this is a safety hazard.

____________________________________________________________________________

Where it is: External meter box What it is: Council sticker saying not approved. Results: The house may not be certified this will require further investigation by a legal person to determine if this property has been certified or not. Reporting on compliance is outside the scope of this standard inspection and report.

Page 14: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 14 of 26

ALLINSPECT 1300254677 Page 14

Brisbane, Gold Coast, Ipswich

Where it is: External What it is: The tank and HWS are leaking. Results: This could be detrimental to the performance of the system and the rainwater tank. It is conditions conducive to termites as well. Recommend a Competent Person to determine the method and the extent of any remedial work required, and associated costs. The above recommendations should be implemented as soon as possible.

____________________________________________________________________________

Where it is: External Widespread What it is: Wood Rot to the verandas, nails popping through Results: The structures are showing signs of deterioration as a results of damp conditions which has created the timbers to rot. Regular maintenance of the timbers is required to prolong the life of this building element which may include but not limited to (Painting, sealing) Recommend to first identify the cause of the timber rot, then replace the affected timber where required, the timeframe for this depends on the severity of the rot. Recommend a Competent Person to determine the method and the extent of any remedial work and costs. The above recommendations should be implemented as soon as possible.

Page 15: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 15 of 26

ALLINSPECT 1300254677 Page 15

Brisbane, Gold Coast, Ipswich

____________________________________________________________________________

Where it is: External What it is: Damage fittings (Air-con). Results: The adequacy and testing of electricity is outside the scope of this standard inspection and report. Recommend a competent person like a Licensed Electrician to determine the method or work required and associated costs. The above recommendations should be implemented straight away as a matter of urgency.

Page 16: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 16 of 26

ALLINSPECT 1300254677 Page 16

Brisbane, Gold Coast, Ipswich

D2.5 Internal

Where it is: Internal Bathroom and adjacent Wall, subfloor What it is: High Moisture and evidence of leaking and water damage. Results: High Moisture was noted in wall, which can cause conditions conducive to structural damage. Under test conditions it was revealed that high moisture was evident in the secondary wall adjacent to the shower. Damp or wet conditions generally indicate a leak or poor ventilation, or failure of the waterproofing. Recommend a Plumber, to determine the cause and the method. The above recommendations should be implemented as soon as possible.

___________________________________________________________________________

Page 17: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 17 of 26

ALLINSPECT 1300254677 Page 17

Brisbane, Gold Coast, Ipswich

Where it is: Internal All Toilets What it is: Toilets leaking – active. Results: As the surrounding area was found to be damp at the time of inspection the leak is ongoing and requires urgent action as it can cause conditions conducive to structural damage Regardless of the location if left unmanaged leaks can lead to serious damage of associated building elements and result in the need for replacement of building materials. Mould and other hazards such as electrical hazards may also arise if left unmanaged. A licensed plumber should be appointed to further investigate the leak. The above recommendations should be implemented as soon as possible.

____________________________________________________________________________

Page 18: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 18 of 26

ALLINSPECT 1300254677 Page 18

Brisbane, Gold Coast, Ipswich

D3: Minor defects

Where it is: External Roof What it is: Gutters & Valleys blocked with debris (leaf litter) Results: When you have blocking of the gutters/valleys and downpipes, they may lead to pooling of water and water may overflow into the eaves and exterior walls causing secondary defects, which can lead to conditions that are conducive to structural damage. Also the pooling of water can cause the gutters/valleys to rust and it also provides conditions that are conducive to termites. Recommend a licensed roof plumber for advice if there is significant damage to the general handyman to remove leaf litter and clean gutters/valleys. The above recommendations should be implemented as soon as possible.

Page 19: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 19 of 26

ALLINSPECT 1300254677 Page 19

Brisbane, Gold Coast, Ipswich

Where it is: External What it is: Storm water Damage/Missing not adequately connected. Results: Roof plumbing is not adequately connect to drainage which can cause conditions conducive to structural damage. When the roof plumbing does not drain adequately, the area can become quite damp and may lead to conditions conducive to structural damage, and it is also an environment that is conducive to termites. Recommend a plumber to repair or replace damage or missing roof plumbing. The above recommendations should be implemented as soon as possible.

____________________________________________________________________________

Where it is: External Wall What it is: Cracking Results: When minor cracks are in external walls, they are often considered to be an appearance defect, generally the cause may be expansion and contraction of the mortar due to environmental factors or it may be due to trees and their roots. Sometimes it can be due to poor insulation of the bricks when it was first laid. Recommend a Register Tradesman to repair this. Always monitor these cracks and if they should widen or become more numerous contact your building inspector.

____________________________________________________________________________

Page 20: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 20 of 26

ALLINSPECT 1300254677 Page 20

Brisbane, Gold Coast, Ipswich

Where it is: External What it is: Cracked Window. Results: Cracking in windows may be caused by impact damage. Any cracked glass is a safety hazard and may allow water to penetrate into the surrounding building elements. It is highly recommend that a qualified glazier repair or replace the broken or cracked glass. The above recommendations should be implemented straight away as a matter of urgency.

____________________________________________________________________________

Where it is: Internal What it is: Main bathroom shower shelve is missing and a few doors are binding/stiff. Results: Although some building elements may seem irrelevant or unnecessary all building elements have a purpose in the overall function and performance of that building element. Recommend to rectify the defective building element, so as to have it fully functional as it is intended.

____________________________________________________________________________

Page 21: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 21 of 26

ALLINSPECT 1300254677 Page 21

Brisbane, Gold Coast, Ipswich

Where it is: Internal What it is: Cracking Results: When small localised cracks are noticeable, most times they are only an appearance defect and usually do not indicate that there is any structural damage. Generally, the cause is normal wear and tear over a period of time of the separation of building material and the paint and plaster along the joins. Always contact a building inspector should they become bigger or more numerous to further investigate. Cracking of this nature can be repaired with minor sanding and filling and repainting by a handyman or tradesman such as a painter. Always monitor these cracks and if they should widen or become more numerous contact your building inspector.

____________________________________________________________________________

Where it is: Internal Bedroom What it is: Flaky Paint Results: Flaky or missing paint is normally just an appearance defect, it can also lead to deterioration of the building element as it is nor sealed as it should be. Incomplete building elements can become affected by moisture which can then lead to conditions which can be conducive to structural damage. Incomplete painted areas should be painted to protect the underlying building element. Recommend a painting contractor to repair the painting. The above recommendations should be implemented as soon as possible.

____________________________________________________________________________

Page 22: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 22 of 26

ALLINSPECT 1300254677 Page 22

Brisbane, Gold Coast, Ipswich

Where it is: Internal Bathrooms and Kitchen What it is: Grout/Sealant is inadequate, Results: Over time sealant and or grout can become deteriorated without proper maintenance, and can cause the area not to be water tight and may allow water penetration in to adjacent walls or floors, which can cause conditions conducive to structural damage. Recommend tiling contractor to repair or replace grout or sealant. The above recommendations should be implemented as soon as possible.

____________________________________________________________________________

Page 23: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 23 of 26

ALLINSPECT 1300254677 Page 23

Brisbane, Gold Coast, Ipswich

Where it is: Internal Bedroom Window Sills What it is: Weathered timber Results: When timber is exposed to the environment such as the weather it can become deteriorated over a period of time and cause Fungal Decay to the timbers, and it is then can become conducive to termites. The removal or rectification of these timbers that are weathered or have become fungal decay is recommended to minimize the risk of termite attack and secondary defects that can become conducive to structural damage. Depending on the level of damage to the building element, depends on what trades are required. The above recommendations should be implemented as soon as possible.

____________________________________________________________________________

Where it is: Internal Bathroom What it is: Old repairs– appears to have an evidence of repairs Results: When there is evidence of repairs, the most critical factor is identifying the specific causes that have created these defects, and identifying if this is a recurring or ongoing problem or one that has been unresolved or resolved by the owner’s actions in the past. Please obtain from owner in writing as to why the property was repaired. Please be aware that linings when removed or replaced may reveal other currently concealed damage they are covering.

____________________________________________________________________________

Page 24: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 24 of 26

ALLINSPECT 1300254677 Page 24

Brisbane, Gold Coast, Ipswich

Where it is: Kitchen What it is: Fitting or fixture non-operational. Results: The range-hood light and toilet was found to be not operating correctly at the time of inspection. The adequacy and testing of appliances are outside the scope of this standard inspection and report. Recommend a competent person like a Licensed Electrician to determine the method or work required and associated costs. The above recommendations should be implemented straight away as a matter of urgency.

_____________________________________________________________________

Where it is: A few areas What it is: Damage switch and soap holder Results: Although some building elements may seem irrelevant or unnecessary all building elements play a key role in the operation and function of the overall structure and its performance. Replacement of any damage building element should be conducted as soon as possible. Depending on the building element which is damage, depends on what trades are responsible for such works, which may include but not limited to, plumber, electrician, builder or general handyman.

____________________________________________________________________________

Page 25: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 25 of 26

ALLINSPECT 1300254677 Page 25

Brisbane, Gold Coast, Ipswich

Section E Conclusion

In the opinion of this Consultant:

The incidence of Major Defects in this property in comparison to the average condition of similar buildings of approximately the same age that have been reasonably well maintained was considered: Below Average.

The incidence of Minor Defects in this property in comparison to the average condition of similar buildings of approximately the same age that have been reasonably well maintained was considered: Below Average.

The report describes the overall extent of any minor defects and imperfections: There are many Minor Defects. Monitoring and normal maintenance must be carried out (see also Section F ‘Important note’).

In conclusion, following the inspection of surface work in the readily accessible areas of the property, the overall condition of the building relative to the average condition of similar buildings of approximately the same age that have been reasonably well maintained was considered: Below Average Condition.

Your attention is drawn to the advice contained in the Terms and Conditions of this Report including any special conditions or instructions that need to be considered in relation to this Report.

Section F Important note

Australian Standard AS4349.0-2007 Inspection of Buildings, Part 0: General Requirements recognises that a property report is not a warranty or an insurance policy against problems developing with the building in the future. Accordingly, a preventative maintenance program should be implemented for the property which includes systematic inspections, detection and prevention of incipient failure. Please contact the Consultant who carried out this inspection for further advice.

Section G Other comments

Suspected Asbestos This suspected defect is highlighted as a caution only. We suspect based on our experience in the building industry that there is a higher risk of the building containing asbestos. The client is advised to act with caution especially when considering any damage to building materials general wear and tear renovations extensions demolition and general maintenance activities due to the suspected presence of Asbestos.

____________________________________________________________________________

Page 26: This is a visual only Building Inspection & Report carried ... · Pre-Purchase REPORT (hereinafter called the “Report”) Inspection Date: 21/01/2020 Property Address: A15 Sample

Page 26 of 26

ALLINSPECT 1300254677 Page 26

Brisbane, Gold Coast, Ipswich

Section H Certification

This document certifies that the property described in this Report has been inspected by the Building Consultant in accordance with the level of service requested by the Client and the Terms and Conditions set out in this Report, and in accordance with the current edition of the Report Systems Australia (RSA) Handbook Standard Property Inspection Reports ‘Uniform Inspection Guidelines for Building Consultants’.

Authorised Signatory: David Tacon

Name: David Tacon Date of Issue: 21 January, 2020