this is one of the drawings secret mystery-62-g …
TRANSCRIPT
SITE ADDRESS:
THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :OWNER ................................DATE...............................
OWNER ...............................DATE................................
BUILDER ...............................DATE................................
DATE: 19/01/2021SCALE: 1:100, 1:1
JOB N°:REVISION N°:
VARIATIONS:
04
SALES: DRAWN:SH JB ARCHECKED:
SHEET N°: of 11
2008005
GROUND FLOOR PLAN (A2)
02
REV: DESCRIPTION: INT: DATE: ADENEY
LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150
CLIENT: SECRET MYSTERY-62-G
BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102
Copy
right
2011
©
/C1S/
/C2S/
/BS/
/C1D/
/C2D/
/BD/
'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'
AREASNameHOUSE - GROUNDHOUSE - UPPERGARAGE/STOREALFRESCOPORCH
Area172.78765.39840.95719.29211.210309.644 m²
Perimeter64.56033.33025.96019.38015.600
SITE CLASSIFICATION : AFOOTING DETAIL : R.T. ENGS.WIND CATEGORY : N1CORROSION CLASS : R3
INTERNAL DOORS NOTE:ALL INTERNAL DOORS TO BE 2040H (25C) U.N.O.
BUILD METHOD: TFTW GROUND FLOOR: Double Brick, Slab on Ground UPPER FLOOR SLAB: Timber Truss Flooring System UPPER FLOOR WALLS: Timber Wall, 100mm Thermal Clad ROOF TYPE: Colorbond INTERNAL PLASTER: Premium Wall System
CL @ 31c THRU'OUTALL UNLESS OTHERWISE NOTED
BRICKLAYER NOTE:RUN KITCHEN & SCULLERY BENCHTOP UNDER WINDOW FRAME.
CUT BWK DOWN TO SUIT BENCHTOP SELECTION.
RENDER NOTE:EXTENT OF RENDER COLOUR 1 TO PORCH RHS T-BAR, FRONTOF STUDY, ENTIRE UPPER FLOOR AND RETURN EXCLUDING UF
FRONT & RHS OF BED 2.EXTENT OF RENDER COLOUR 2 TO GROUND FLOOR FRONT
ELEVATION, PORCH WALL & PIER.EXTENT OF NOMNATED CLADDING TO FRONT ELEVATION, RHS &
LHS RETURN OF BED 2. EXTENT OF RENDER AS PER PLAN.
TERMITE TREATMENT NOTE:TERMITE TREATMENT WILL BE CARRIED OUT INACCORDANCE WITH PART 3.1.3.2 OF THE NCC -
BUILDING CODE OF AUSTRALIA AND AS3660.1:2014 THROUGHTHE USE OF TERMITE RESISTANT MATERIALS FOR ALL
PRIMARY BUILDING ELEMENTS, AS FOLLOWS:*CONCRETE SLAB IN ACCORDANCE WITH AS2870 & AS3600
*MASONARY IN ACCORDANCE WITH AS3700 *PRESERVATIVETREATED TIMBER IN ACCORDANCE WITH AS1604 AND
APPENDIX D OF AS3660.1:2014
FIRE PROTECTION
RAKING BULKHEAD
SQUARE BULKHEAD
BOX GUTTER
RECESSED CEILING
SD
SD
17x910 A
8x2
310
FO
BSTO
UG
HEN
ED 8
x241
0 F
28x
2410
28x3610 SD
28x
2410
28x
1010
28x
1010
7x2
410
DBL
GLA
ZED
5x3
010
F
28x
2410
REMOTE CONTROLSECTIONAL DOOR
820MF 820
MF
2x7
2018
0° H
ING
ES1s
t
2143
x200
0D
HO
820
2143x920DHO
820
820
3x F
ULL H
T. S
LIDER
S(S
OFFI
T OV
ER)
28x
1610
SD
13x
610
82010
20 AF
4x8
10 F
4030 x 3640
3530 x 3570
4490 x 4410
6430 x 5700
6890 x 2800
3360 x 2080
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
MH
INT D.P
D.P
D.P
8,7905,8901,0001,900
3905,0104901,000400
910590
32,59
06,0
905,6
107,8
9010
,200
2,800
6,090
2,800
2,410
400
890
2,410
990
3,010
590
300
2,410
890
1,010
3,490
1,010
1,090
2,800
8,7908005006,890600
8005001,6903,6101,590600
32,59
050
01,4
005,9
003,6
905,0
107,5
905,7
002,8
00
500
1,400
4,590
1,080
230
2,490
810
390
610
2,490
1,610
300
390
2,410
1,490
2,310
990
1,500
2,410
1,790
2,800
930 19
01,1
1029
01,1
1029
01,1
1029
01,1
1050
090
901001,110290
1,0202901,200290
1,300
370930
420
800
700
850
2,000
850
150
90
50
600
730
1,350
6,000
1,071
1,571
1,671
200
1,000
1,500
3251,190325
500
3,390
500
1,000
3,700
1,000
8004,830800
771
3,000
500
901,3
0030
091
029
091
029
091
050
090
500
140
6,367
6,926
15,013
15,306
1,07165 65
1,500
670 1,000
1,690
1
4
EXTENT OFRENDER COLOUR 1
SHOWN DASHED
EXTENT OFUF CANTILEVERSHOWN DASHED
EXTENT OFUPPER FLOOR
SHOWN DASHED
TOP OF POSTFTGS. @ -3c
EXTENT OFRECESSED CL
SHOWN DASHED
EXTENT OFRENDER COLOUR 2
SHOWN DOTTED
UPSTAND WALL@ 33c
TOP OF PIERFTG. @ -3c
T-BAR @ 25c
GARAGE28c CL PLASTERBOARD
GRANO @ -1c2nd FACE BRICK
WORK INTERNALLY
STOR
E
2x S
HELF
& R
AIL
BANK OF 4DRAWERS
3x BANK OF3 DRAWERS
FLUMEDINT/ R/HOOD
GAS HP
2xWO
POTDRAWER
350d
O/H
CPBD
S35
0d O
/HCP
BDS DW
RECDWTAP VO
IDOV
ERHA
NG
300d
O'H
EAD
CPBD
SFR RE
C
UNDE
RMOU
NTSI
NK &
MIX
ERELEC/PLUMBPRELAY
PTY.
4x S
HELV
ES
THEATRE
STUDY
MASTER SUITE
MEALS
FAMILY
ALFRESCO
KITCHEN
ENSUITETILED
WIR
4x SHELVES
WIL
TILED
L'DRYTILED
WMREC
B'TOPONLY
HOBL
ESS
2000HTILEDWALL
31c CLTHROUGHOUT
PDRTILED
CAVITYCLOSER
CAV.CLOSER
LINING TOU/S OFSTAIRS
STORE TIMBERSTAIRS
1050H BALUSTRADEOVER RAKED WALL
RAKED WALLUNDERSTAIRS
FFL = 00cCL = 31c
PORCH28c CL
P'BOARDPAVED @ -1c
T-BAR @ 25c
T-BA
R @
28c
BOUN
DARY
WAL
L @
29c w
/- SQ
UARE
LINE
GUT
TER
TO B
E SE
TBAC
K 10
0mm
FRO
M BO
UNDA
RY
PHYS
ICAL
TER
MITE
BAR
RIER
&FI
RE S
EPAR
ATIO
N RE
QUIR
ED
STORMWATERPRELAY
UNDER SLAB
EXTENT OFRENDER
COLOUR 1
EXTENT OFRENDER
COLOUR 1EXTENT OF
RENDERCOLOUR 2
EXTENT OFRENDER
COLOUR 2
OVER
ALL
WW
WW
WW
31c CL PLASTERBOARDPAVED @ -1c 28
c EAV
ES
28c E
AVES
LVLLVL
LVL
LVL
T-BAR OVER
OVERALL
SD
D
OVER
ALL
DW
WSD
WW
W
OVERALL
GARAGE OPENINGW
LOCATION OFFUTURE PCD
COMBM/BOX
INST.GASHWU
BOUN
DARY
LINE
BOUN
DARY
LINE
BOUNDARY LINE
STAIR INFORISER HEIGHT = 181.9TREAD WIDTH = 250
BOX GUTTEROVER
SPANDREL28c - 31c
550x550
ENTRY
31c CL
31c C
L
31c CL
EXTENT OFRECESSED CL
SHOWN DASHED
34c R
ECES
SED
CL
34c RECESSED CL
31c CL
31c C
L
31c C
LSC
LRY
FRREC600w 28c SQ.
BULKHEAD
600w 28c SQ.BULKHEAD
1900HTILEDWALL
BR
1050HHANDRAIL
SHELF& RAIL
SHELF& RAIL
28c EAVES
PLUMB DUCTw/- ACCESS PANEL
SILL @ 3cHEAD @ 7c
T.O.F.@ -3c
T.O.F. @ -3c
SKYLIGHTPOSITION
TBC
31c C
L
TRAN
SLUC
ENT
GLAZ
ING
REVERSE CYCLEA/C UNIT
900L x 500W x 50HCONCRETE SLAB
3
SHR
1 2 3 4 5 6 7 8
9
UP
5900 x 5810
1900 x 5900
850
2,000
850
RAKI
NG B
'HEA
D
2/ 550mm x700mm
2
TOTAL
SITE ADDRESS:
THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :OWNER ................................DATE...............................
OWNER ...............................DATE................................
BUILDER ...............................DATE................................
DATE: 19/01/2021SCALE: 1:100, 1:1
JOB N°:REVISION N°:
VARIATIONS:
05
SALES: DRAWN:SH JB ARCHECKED:
SHEET N°: of 11
2008005
UPPER FLOOR PLAN (A2)
02
REV: DESCRIPTION: INT: DATE: ADENEY
LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150
CLIENT: SECRET MYSTERY-62-G
BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102
Copy
right
2011
©
/C1S/
/C2S/
/BS/
/C1D/
/C2D/
/BD/
'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'
AREASNameHOUSE - GROUNDHOUSE - UPPERGARAGE/STOREALFRESCOPORCH
Area172.78765.39840.95719.29211.210309.644 m²
Perimeter64.56033.33025.96019.38015.600
UPPER FLOOR CONSTRUCTION NOTEALLOW EXTRA STUDWORK FOR: - WC ROLL HOLDER @ 750mm - TOWEL RAIL @ 1000mm - TOWEL RING @ 1200mm - TOILET @ 750mm
UPPER FLOOR GLAZINGUPPER FLOOR WINDOWS TO COMPLY WITH BCA 3.9.2.5
UPPER FLOOR HEIGHTSFFL =3092mmCL = 5527mmHEIGHT O/A= 2435mm (28c)
CL @ 28c THRU'OUTALL UNLESS OTHERWISE NOTED
SITE CLASSIFICATION : AFOOTING DETAIL : R.T. ENGS.WIND CATEGORY : N1CORROSION CLASS : R3
INTERNAL DOORS NOTE:ALL INTERNAL DOORS TO BE 2040H (25C) U.N.O.
BUILD METHOD: TFTW GROUND FLOOR: Double Brick, Slab on Ground UPPER FLOOR SLAB: Timber Truss Flooring System UPPER FLOOR WALLS: Timber Wall, 100mm Thermal Clad ROOF TYPE: Colorbond INTERNAL PLASTER: Premium Wall System
RENDER NOTE:EXTENT OF RENDER COLOUR 1 TO PORCH RHS T-BAR, FRONTOF STUDY, ENTIRE UPPER FLOOR AND RETURN EXCLUDING UF
FRONT & RHS OF BED 2.EXTENT OF RENDER COLOUR 2 TO GROUND FLOOR FRONT
ELEVATION, PORCH WALL, PIER & UPPER FLOOR FRONTELEVATION OF BED 2.
EXTENT OF WEATHERBOARD CLADDING TO PORTIONS OF BED 2FRONT & RHS WALLS AS SHOWN ON PLANS.
TERMITE TREATMENT NOTE:TERMITE TREATMENT WILL BE CARRIED OUT INACCORDANCE WITH PART 3.1.3.2 OF THE NCC -
BUILDING CODE OF AUSTRALIA AND AS3660.1:2014 THROUGHTHE USE OF TERMITE RESISTANT MATERIALS FOR ALL
PRIMARY BUILDING ELEMENTS, AS FOLLOWS:*CONCRETE SLAB IN ACCORDANCE WITH AS2870 & AS3600
*MASONARY IN ACCORDANCE WITH AS3700 *PRESERVATIVETREATED TIMBER IN ACCORDANCE WITH AS1604 AND
APPENDIX D OF AS3660.1:2014
BOX GUTTER
SD
514x
2410
857x
1810
F
1972x2410 A
1972x1210 A
772x2010
820
8202x FULL HT. SLIDERS(SOFFIT OVER)
720
4.5m CONE OF VISION 4.5m CONE OF VISION
3600 x 3130
3600 x 3520
3380 x 4090
4.5m CONE OF VISION
MH
D.PD.P
D.PD.P
1
4
3
7,4503,9052,0101,535
9,215
1,345
7,870
9,215
4,075
2,410
590
1,810
330
7,3655,0102,355
7002,4102,3851,210660
21,42
0
1,340
40
600
500
2,5001,100
840
500
1,400
190
400
EXTENT OFNOM. CLADDINGSHOWN DOTTED
100mm THERMAL CLADDINGTO OUTSIDE OF STUD
(EXTENT SHOWN DASHED
BATHTIMBER STAIRS
1050H BALUSTRADE
TILED
HOBLESS BATHLINEN
ROBE
ACTIVITY
BED 3
BED 2
33cUPSTAND
2x FULL HT. SLIDERS(SOFFIT OVER)
ROOFBELOW
ROOFBELOW
BOUN
DARY
LINE
BOUN
DARY
LINE
BOUNDARY LINE
550x550 STAIR INFORISER HEIGHT = 181.5TREAD WIDTH = 250
STAIR INFORISER HEIGHT = 181.9TREAD WIDTH = 250
BOX GUTTER
EXTENT OFCLADDING
OVERALL
WW
OVER
ALL
WW
OVER
ALL
OVERALL
W
1050H HANDRAIL
1050HHANDRAIL
HOB MTD.SHR SCREEN
EXTENT OFCLADDING
4x SHELVES
AC
SKYLIGHTPOSITION
TBC
WIR
1 2 3 4 5 6 7 8
9
1011121314151617DN
2
SHR
2/ 550mm x700mm
TOTAL
JOB REF: 2008005R
101 Residential Pty Ltd 9208 9100 [email protected]
DEVELOPMENT APPLICATIONSUPPORTING LETTER
LOT 705 (#56B) KENNEDY STREET, ALFRED COVE
SITE ADDRESS:OWNER ................................DATE...............................
OWNER ...............................DATE................................
BUILDER ...............................DATE................................
DATE: 19/01/2021SCALE: 1:200, 1:100
JOB N°:REVISION N°:
VARIATIONS:
03
SALES: DRAWN:SH JB ARCHECKED:
SHEET N°: of 11
2008005
SITE PLAN
02
REV: DESCRIPTION: INT: DATE: ADENEY
LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150
CLIENT: SECRET MYSTERY-62-G
BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102
Copy
right
2011
©
THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :
/C1S/
/C2S/
/BS/
/C1D/
/C2D/
/BD/
'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'
SITE CLASSIFICATION : AFOOTING DETAIL : R.T. ENGS.WIND CATEGORY : N1CORROSION CLASS : R3
- LOCATION OF SERVICES
STORMWATER NOTE:STORMWATER DISPOSAL TO ENGINEER'S
DETAILS.
CONCRETE NOTE:SET SHOWER RECESS DOWN 50mm (25mm
BELOW 25mm SET DOWN) & FIT REFLUXVALVE. MAINTAIN REQUIRED SLAB THICKNESS
TO ENGINEERS REQUIREMENTS
TERMITE TREATMENT NOTE:TERMITE TREATMENT WILL BE CARRIED OUT INACCORDANCE WITH PART 3.1.3.2 OF THE NCC -
BUILDING CODE OF AUSTRALIA ANDAS3660.1:2014 THROUGH THE USE OF TERMITE
RESISTANT MATERIALS FOR ALL PRIMARYBUILDING ELEMENTS, AS FOLLOWS:
*CONCRETE SLAB IN ACCORDANCE WITHAS2870 & AS3600
*MASONARY IN ACCORDANCE WITH AS3700*PRESERVATIVE TREATED TIMBER IN
ACCORDANCE WITH AS1604 AND APPENDIX DOF AS3660.1:2014
Proposed Panel+ Post Retaining.
Panel & PostRetaining (required)
ELECTRICAL NOTE:3 - PHASE POWER
PRELAY NOTE:PLUMBING & ELECTRICAL PRELAY REQUIRED FOR
ISLAND CUPBOARD REFER TO FLOOR PLAN
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
SITE COVERAGEZONED R20% ALLOWED 50%SITE AREA 544.00m2
SITE COV. AREA 219.05m2
OPEN SPACE =59.7%
SW1.2 x 0.9
SW1.2 x 0.9
SW1.2 x 1.2
SW1.2 x 1.2
Soak Well TypeNo.SW 1200x90022.0 m3SW 1200x120022.7 m3
Total Capacity4.8 m3Roof Area GF203.9 m2Paved Area27.8 m2Roof Area UF80.1 m2Total Area311.8 m2Capacity Required (Area x 0.0125)3.9 m3Extra Capacity Provided0.9 m3
NOTE: ALL DOWNPIPES CONNECTEDTO SOAKWELLS WITH PVC
STORMWATER PIPE
INT D.P
D.P
D.P
6,000
1,071
1,801
1,6711,500
6,000
6,090
5,610
7,890
10,20
018
,183
1,071 7,490 500 1,000
6,624
7,800
3,690
5,010
7,590
5,700
17,75
6
1,071 1,900 5,590 500 1,000
1,000
771
200
6,367
6,928
15,306
15,013
1,050
1,500
EXTENT OFUF CANTILEVERSHOWN DASHED
0.003 mLOT MISCLOSE
53.97
9 3 ° 3 3 '0 "
10.08
8 6 ° 2 7 '0 "54
.17
9 2 ° 2 6 '0 "
10.07
87°34'
0"
10 .2810 .25
10 .3010 .26
10 .3710 .35
10 .38 10 .33
10 .6010 .68
10 .85 10 .84
10 .93
10 .84
10 .8610 .81
10 .9110 .9310 .96
10 .961 0 .9 21 0 .8 8
10.7
510
.74
10.4
610
.34
10.1
910
.05
10.1
8
1 1 .9 71 1 .0 7
10 .14
10 .12
10 .0910 .07
10 .07
9 .959 .9 7
9 .9 1
10 .1110 .20
1 0 .0 39 .9 5
1 0 .0 7
VACANT
DUG TO LEVEL10.09 ON LOT(SAND/ POSS
L/STONE)
Comm
s Con
n.
Sewe
r I.O
.
PEG FNDNUMB
C
10.7
110
.54
10.3
410
.20
10.0
3
TF[ ]TF[ ]
1 0 .0 6TF[ ]
Brick & Galv.On Slab
Brick & Galv.On Slab(Clear)
Sewer M/H
Approx. 19.7m
(10.02)>>> >>>
Ref Nail At Base Of KerbAssumed Datum 10.00 m
Verge TreeØ 0.60mHt 7.0m
Step
ped C
olorb
ond
Fenc
e (Go
od C
ond.)
Step
ped C
olorb
ond
Fenc
e (Go
od C
ond.)
Sewer JunctionIn: 3.5 Up: 1.4Inv: 8.5 Depth: 0.2NOTE: UP
BEWARE:Shallow sewer junction.Check With Water CorpBUILDER and PLUMBERcheck GRADE.
10.0
10.7
5
1 0 .9 21 0 .9 21 0 .9 2
1 0 .5 8
PAINT MARK FOUND ONFENCE OFFSET 0.12mPAINT MARK FOUND ON
FENCE OFFSET 0.12m
.
1:200cJ/N: DATE: DRAWN:SCALE:
Licensed Surveyors
87-89 Guthrie Street, Osborne Park, Western AustraliaTelephone: (08) 9446 7361 Facsimile: (08) 9445 2998
Email : [email protected] Website: www.cottage.com.au
Lot boundaries drawn on survey arebased on landgate plan only. Survey does notinclude title search and as such may not showeasements or other interests not shown on plan.Title should be checked to verify all lot detailsand for any easements or other interests whichmay affect building on the property.
Survey does not include verification of cadastralboundaries. All features and levels shown arebased on orientation to existing pegs and fencesonly which may not be on correct cadastral alignment.Any designs based or dependent on the location ofexisting features should have those features'location verified in relation to the true boundary.
Survey shows visible features only and will notshow locations of underground pipes or conduitsfor internal or mains services. Verification ofthe location of all internal and mains servicesshould be confirmed prior to finalisation of anydesign work.
Cottage & Engineering surveys accept noresponsibility for any physical on site changes tothe parcel or portion of the parcel of land shownon this survey including any adjoining neighbourslevels and features that have occurred after thedate on this survey. All Sewer details plottedfrom information supplied by Water Corporation.
DISCLAIMER:
DISCLAIMER:
DISCLAIMER:
DISCLAIMER:
SEC DomePower PolePhone Pits
LEGE
ND T C
TP 10.00TWTRTF
[[[[
10.0010.0010.00
]]]]
Top Pillar/PostTop WallTop RetainingTop Fence
W Water Conn.
K e n n e d y S t r e e tBitumen
OLDAREA
Scale 1:200
0 2 4 6 8
W
S
E
N
SOIL DESCRIPTIONSandMedium Grass Cover
477477 21 Aug 20 J.Genovese
Builder : 101 Residential Pty LtdCLIENT : ADENEYLOT 705 #56B Kennedy Street, Alfred Cove
D.Plan418486
ConcreteNon-Mount
Non-MountNil
Brick PavedCrossover
Brick PavedDriveway
Brick PavedDriveway
OverhangingTree
Galv. Shed
Galv. Shed
GarageUMR
Poss
ible P
arap
et W
all
Approx. F/L10.55
Colorbond Fence(Good Cond.)
Appr
ox. F
ootin
gLe
vel 1
0.45
10.5
PEGGONE
Slope
LOCATION OFFUTURE PCD
COMBM/BOX
INST.GASHWU
ELEC/PLUMBPRELAY
DW TAP
PROPOSEDRESIDENCEFFL 10.475SPL 10.390
ALFRESCOGRANO @ -1c
PORCHPAVED @ -1c GARAGE
GRANO @ -1c
STOR
E
SETBACK
SETBACK
SETBACK
SETBACK
SETBACK
SETBACK
SETBACK
SETBACK
SETBACK
1m PATH
DRIVEWAY SETB
ACK
CROSSOVERTO COUNCIL'S
SPECIFICATIONS
BOUNDARY WALL @ 29cw/- SQUARELINE GUTTERTO BE SETBACK 200mm
FROM BOUNDARYPHYSICAL TERMITE BARRIER &FIRE SEPARATION REQUIRED
STORMWATERPRELAY
UNDER SLAB
SETBACK
SETBACK
T.O.F.@ -3c
T.O.F.@ -3c
SETBACK
SETBACK
REVERSE CYCLEA/C UNIT
900L x 500W x 50HCONCRETE SLAB
SKYLIGHTPOSITION
TBC
T.O.R. @ 10.580
T.O.R. @ 10.580
T.O.R. @ 10.580
B.O.R. @ 10.460
B.O.R. @ 10.050B.O.R. @ 10.390
2/ 550mm x 700mm
SITE ADDRESS:DATE: 19/01/2021SCALE: 1:100
JOB N°:REVISION N°:
VARIATIONS:
06
SALES: DRAWN:SH JB ARCHECKED:
SHEET N°: of
200800502
REV: DESCRIPTION: INT: DATE:
LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150
CLIENT:
ELEVATIONS 01ADENEY
SECRET MYSTERY-62-G
11
T H I S I S O N E O F T H E D R A W I N G SR E F E R E D T O I N T H E C O N T R A C T :O W N E R ................................DATE...............................
O W N E R ...............................DATE................................
B U I L D E R ...............................DATE................................B U I L D E R S R E G I S T R A T I O N N ° 1 3 5 2 19 S A N G I O R G I O C O U R TO S B O R N E P A R K W A 6 0 1 7P h o n e (0 8 ) 9 2 0 8 9 1 0 0 F a x (0 8 ) 9 2 0 8 9 1 0 2
Copy
right
2011
©
/C1S/
/C2S/
/BS/
/C1D/
/C2D/
/BD/
'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'
CL 2692 (2692mm)
CL 5527 (5527mm)
2,692
400
2,435
TOP OF PIERFTG. @ -3c
COLORBOND GUTTERS,FASCIA AND DOWNPIPES
25° PITCH COLORBOND ROOF
AUTO SECTIONAL DOOR
T-BAR @ 25c
NOMINATEDCLADDING
T-BAR @25cBLADE WALL
REND
ER C
OLOU
R 2
PIER
RENDERCOLOUR 1 BO
UNDA
RY LI
NE
THERMAL CLADDINGw/- RENDERCOLOUR 1
NGL
CORNERMOULDING
WINDOW MOULDINGSTO SUIT NOMINATED
CLADDING THROUGHOUT
FL 3092 (3092mm)
FL 0 (0c)
5309
3337
5309 5309 5309
28c
33c
11c
25c 2400
3337
T.O.F. @ -3c
25c
4709 4709
CL 2692 (2692mm)
CL 5527 (5527mm)
2,692
400
2,435
PROPOSED RETAINING WALL
TOP OF PIERFTG. @ -3c
TOP OF POSTFTG. @ -3c
PROPOSED SILLS 10mmRECESSED
FACE BRICK
NOMINATEDCLADDING
THERMAL CLADDING w/-RENDER COLOUR 1
ENTRYDOOR
TRANSLUCENTGLAZING
T-BAR @ 28c
PIER
RENDERCOLOUR 2
TOUGHENEDOBS
INST.GAS HWU
PROPOSED
EG
COMBM/BOXLOCATION OF
FUTURE PCD
NGL
CORNERMOULDING
FL 3092 (3092mm)
FL 0 (0c)T.O.R. @ 10.580T.O.R. @ 10.580
2400 28c 24c
28c 28c
0c
19c 11c
19c 11c
5309 5309
28c
10c
0c
28c 28c
0c
14c
7c 6cT.O.F. @ -3c
15c
RENDER NOTE:EXTENT OF RENDER COLOUR 1 TO PORCH RHS T-BAR, FRONTOF STUDY, ENTIRE UPPER FLOOR AND RETURN EXCLUDING UF
FRONT & RHS OF BED 2.EXTENT OF RENDER COLOUR 2 TO GROUND FLOOR FRONT
ELEVATION, PORCH WALL & PIER.EXTENT OF NOMNATED CLADDING TO FRONT ELEVATION, RHS &
LHS RETURN OF BED 2. EXTENT OF RENDER AS PER PLAN.
1 ELEVATION1:100
2 ELEVATION1:100
SITE ADDRESS:DATE: 19/01/2021SCALE: 1:100
JOB N°:REVISION N°:
VARIATIONS:
07
SALES: DRAWN:SH JB ARCHECKED:
SHEET N°: of
200800502
REV: DESCRIPTION: INT: DATE:
LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150
CLIENT:
ELEVATIONS 02ADENEY
SECRET MYSTERY-62-G
11
T H I S I S O N E O F T H E D R A W I N G SR E F E R E D T O I N T H E C O N T R A C T :O W N E R ................................DATE...............................
O W N E R ...............................DATE................................
B U I L D E R ...............................DATE................................B U I L D E R S R E G I S T R A T I O N N ° 1 3 5 2 19 S A N G I O R G I O C O U R TO S B O R N E P A R K W A 6 0 1 7P h o n e (0 8 ) 9 2 0 8 9 1 0 0 F a x (0 8 ) 9 2 0 8 9 1 0 2
Copy
right
2011
©
/C1S/
/C2S/
/BS/
/C1D/
/C2D/
/BD/
'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'
CL 2692 (2692mm)
CL 5527 (5527mm)
2,692
400
2,435
3,455 3,995
1,330
TOP OF POSTFTG. @ -3c
SILLS 10mmRECESSEDFACE BRICK
GARAGEDOOR
BOUN
DARY
LINE
THERMAL CLADDINGw/- RENDER COLOUR 1
NGL
COLORBOND GUTTERS,FASCIA AND DOWNPIPES
25° PITCH COLORBOND ROOF
PROPOSEDPROPOSED
RENDERCOLOUR 2
FL 3092 (3092mm)
FL 0 (0c)
28c
5309 5309
28c
0c
24c 28c
33c
5309
4537
33c
T.O.R. @ 10.580T.O.R. @ 10.580
CL 2692 (2692mm)
CL 5527 (5527mm)
2,692
400
2,435
2,2801,2503,1501,2501,370
66
TOP OF POSTFTG. @ -3c
PROPOSED RETAINING WALL
SILLS 10mmRECESSEDFACE BRICK
SPANDREL28c - 31cMOULDING
THERMAL CLADDING w/-RENDER COLOUR 1
BOUNDARY WALL @ 29c w/-SQUARELINE GUTTER TO BE
SETBACK 200mm FROM BOUNDARYPROPOSED
NGL
NOMINATEDCLADDING
CORNERMOULDING
REVERSECYCLE
A/C UNIT
SKYLIGHTSPOSITION
TBC
FL 3092 (3092mm)
FL 0 (0c)T.O.R. @ 10.580
5309
28c 28c
0c
10c
28c
0c
10c
28c
0c
10c
28c 23c
28c 21c
28c
0c
10c
5309
4452
5309 4795
33c
29c 2400
31c 31c
5309550mm x 700mm
RENDER NOTE:EXTENT OF RENDER COLOUR 1 TO PORCH RHS T-BAR, FRONTOF STUDY, ENTIRE UPPER FLOOR AND RETURN EXCLUDING UF
FRONT & RHS OF BED 2.EXTENT OF RENDER COLOUR 2 TO GROUND FLOOR FRONT
ELEVATION, PORCH WALL & PIER.EXTENT OF NOMNATED CLADDING TO FRONT ELEVATION, RHS &
LHS RETURN OF BED 2. EXTENT OF RENDER AS PER PLAN.
BRICKLAYER NOTE:RUN KITCHEN & SCULLERY BENCHTOP UNDER WINDOW FRAME.
CUT BWK DOWN TO SUIT BENCHTOP SELECTION.
3 ELEVATION1:100
4 ELEVATION1:100
SITE ADDRESS:OWNER ................................DATE...............................
OWNER ...............................DATE................................
BUILDER ...............................DATE................................
DATE: 19/01/2021SCALE: 1:1, 1:100
JOB N°:REVISION N°:
VARIATIONS:
08
SALES: DRAWN:SH JB ARCHECKED:
SHEET N°: of 11
2008005
ELECTRICAL PLAN
02
REV: DESCRIPTION: INT: DATE: ADENEY
LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150
CLIENT: SECRET MYSTERY-62-G
BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102
Copy
right
2011
©
THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :
/C1S/
/C2S/
/BS/
/C1D/
/C2D/
/BD/
'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'
NBN PROVISIONAL NOTE
HOUSE TO BE FITTED WITH; - 1x SGPO WITH CONDUIT @ 1400 AFL, - 1x CONDUIT WITH DRAW-WIRE & BLANK PLATE (Cw) @ 1400 AFL FOR FUTURE PHONE/ DATA POINT, - 1x FIBRE COMMUNICATION CONDUIT WITH DRAWWIRE & BLANK PLATE (FC) NBN @ 1400 AFL.
LOCATION OF FUTURE PCD (PREMISESCONNECTION DEVICE) TO BE NOMINATED ON PLANAT PRESTART.TO BE INSTALLED BY NBN PROVIDER.
NOTE:FIBRE COMMUNICATION CONDUIT TO RUN FULLLENGTH FROM (FC) NBN PLATE TO FUTURE PCDLOCATION.
LIGHT SWITCH BOX NOTELIGHT SWITCH BOX TO FIRST FLOOR TO BE 150mm
MINIMUM FROM INTERNAL OPENING
A/C NOTE:LOCATION OF REVERSE CYCLE AIR CONDITIONING
VENTS & ZONING TO BE PLACED BY INSTALLER.
NOTE:3 PHASE POWER REQUIRED.
NOTE:POSITION OF THE FOLLOWING TO BE CONFIRMED
AT PRESTART:- 1x TV POINT- 1x DATA PHOINT- 1x PHONE POINT
GROUND FLOOR ELECTRICAL LEGENDNUM1
1
1
2
1
2
1
Text for legend14w STD Light
AC Control Panel
Data Point
Exhaust Fan Flumed
Phone Point
Smoke Detector
TV Point
Symb14
F
SD
SD
SD
1st
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
D.P
MH
INT D.P
D.P
D.P
LOCATION OFFUTURE PCD
COMBM/BOX
INST.GASHWU
ELEC/PLUMBPRELAY
DW TAP
550x550
GARAGE
STOR
E
THEATRE
STUDY
MASTER SUITE
MEALS
FAMILY
ALFRESCO
ENSUITE
WIR
WIL
L'DRY
PDR
STORE
PORCH
ENTRY
SCLR
Y
FLUMED
FLUM
ED
FLUMEDINT/ R/HOOD
IND HP
KITCHEN1500
REVERSE CYCLEA/C UNIT
900L x 500W x 50HCONCRETE SLAB
SKYLIGHTPOSITION
TBC
SHR
1 2 3 4 5 6 7 8
9
UP
14
F
F
2/ 550mm x700mm
SD
MH
D.PD.P
D.PD.P
550x550
BATH
ACTIVITY
BED 3
BED 2
FLUMED
WIR
1 2 3 4 5 6 7 8
9
1011121314151617DN
SHR F
FIRST FLOOR ELECTRICAL LEGENDNUM1
1
Text for legendExhaust Fan Flumed
Smoke Detector
SymbF
SD
SITE ADDRESS:OWNER ................................DATE...............................
OWNER ...............................DATE................................
BUILDER ...............................DATE................................
DATE: 19/01/2021SCALE: 1:100
JOB N°:REVISION N°:
VARIATIONS:
11
SALES: DRAWN:SH JB ARCHECKED:
SHEET N°: of 11
2008005
PERSPECTIVES
02
REV: DESCRIPTION: INT: DATE: ADENEY
LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150
CLIENT: SECRET MYSTERY-62-G
BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102
Copy
right
2011
©
THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :
/C1S/
/C2S/
/BS/
/C1D/
/C2D/
/BD/
'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'