Class of Accuracy: 1.0 LEDs indicating presence of each Phase. Withstands phase to phase voltage between Phase and Neutral for LT Maintains Accuracy under Current Reversal conditions High Surge Voltage withstand capability up to 8 kV Polycarbonate enclosure. LARSEN & TOUBRO LIMITED THREE PHASE ENERGY METER-EM301 THREE PHASE ENERGY METER-EM301 METERING UKAS

Upload: vuongthien

Post on 31-Jan-2018

680 views

Category:

Documents


70 download

TRANSCRIPT

Page 1: THREE PHASE ENERGY METER-EM301 - · PDF fileTECHNICAL SPECIFICATIONS THREE PHASE ENERGY METER-EM301 Type Three Phase Four Wire Accuracy Class 1.0 Conforms to IS:13779, IEC 61036 Electrical

◆ Class of Accuracy: 1.0

◆ LEDs indicating presence of eachPhase.

◆ Withstands phase to phase voltagebetween Phase and Neutral for LT

◆ Maintains Accuracy under CurrentReversal conditions

◆ High Surge Voltage withstandcapability up to 8 kV

◆ Polycarbonate enclosure.

LARSEN & TOUBRO LIMITED

THREE PHASE ENERGY METER-EM301THREE PHASE ENERGY METER-EM301

METERING

U KAS

Page 2: THREE PHASE ENERGY METER-EM301 - · PDF fileTECHNICAL SPECIFICATIONS THREE PHASE ENERGY METER-EM301 Type Three Phase Four Wire Accuracy Class 1.0 Conforms to IS:13779, IEC 61036 Electrical

TECHNICAL SPECIFICATIONS

THREE PHASE ENERGY METER-EM301

Type■■■■■ Three Phase Four WireThree Phase Four WireThree Phase Four WireThree Phase Four WireThree Phase Four Wire

Accuracy■■■■■ Class 1.0Class 1.0Class 1.0Class 1.0Class 1.0

■■■■■ Conforms to IS:13779, IEC 61036Conforms to IS:13779, IEC 61036Conforms to IS:13779, IEC 61036Conforms to IS:13779, IEC 61036Conforms to IS:13779, IEC 61036

Electrical■■■■■ Current

◆◆◆◆◆ 3 Phase, 4 Wire***** Whole Current IIIIIbbbbb…….5A / 10A / 20A / 50A…….5A / 10A / 20A / 50A…….5A / 10A / 20A / 50A…….5A / 10A / 20A / 50A…….5A / 10A / 20A / 50A

IIIIImaxmaxmaxmaxmax…Up to 600% of I…Up to 600% of I…Up to 600% of I…Up to 600% of I…Up to 600% of Ibbbbb

***** CT Operated

- Basic Current- Basic Current- Basic Current- Basic Current- Basic Current IIIIIbbbbb……..1A / 5A……..1A / 5A……..1A / 5A……..1A / 5A……..1A / 5A

- Maximum Current- Maximum Current- Maximum Current- Maximum Current- Maximum Current IIIIImaxmaxmaxmaxmax…...200% of I…...200% of I…...200% of I…...200% of I…...200% of Ibbbbb

■■■■■ Voltage - - - - - (-30% to+20%)(-30% to+20%)(-30% to+20%)(-30% to+20%)(-30% to+20%)

◆◆◆◆◆ 3 Phase, 4 Wire...63.5V...63.5V...63.5V...63.5V...63.5V, 240V (p-n), 240V (p-n), 240V (p-n), 240V (p-n), 240V (p-n)

■■■■■ Frequency Range

***** 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz +++++ 5 % 5 % 5 % 5 % 5 %LED indication■■■■■ for prfor prfor prfor prfor presence of Phase Vesence of Phase Vesence of Phase Vesence of Phase Vesence of Phase Voltage (R Y B)oltage (R Y B)oltage (R Y B)oltage (R Y B)oltage (R Y B)■■■■■ for Current Reversalfor Current Reversalfor Current Reversalfor Current Reversalfor Current Reversal■■■■■ for Pulse output proportional to energy for Pulse output proportional to energy for Pulse output proportional to energy for Pulse output proportional to energy for Pulse output proportional to energy measuredmeasuredmeasuredmeasuredmeasured.....

Anti Tamper■■■■■ Meter records energy correctly when currentMeter records energy correctly when currentMeter records energy correctly when currentMeter records energy correctly when currentMeter records energy correctly when current

is reversed in one or all phasesis reversed in one or all phasesis reversed in one or all phasesis reversed in one or all phasesis reversed in one or all phases■■■■■ Meter works in the presence of two wiresMeter works in the presence of two wiresMeter works in the presence of two wiresMeter works in the presence of two wiresMeter works in the presence of two wires

(any two phases or a phase & neutral).(any two phases or a phase & neutral).(any two phases or a phase & neutral).(any two phases or a phase & neutral).(any two phases or a phase & neutral).

Display■■■■■ 6 digit Stepper Motor Counter6 digit Stepper Motor Counter6 digit Stepper Motor Counter6 digit Stepper Motor Counter6 digit Stepper Motor Counter

(1 decimal digit)(1 decimal digit)(1 decimal digit)(1 decimal digit)(1 decimal digit)

Operating Temperature■■■■■ 0 to 55 0 to 55 0 to 55 0 to 55 0 to 55 oooooC ambientC ambientC ambientC ambientC ambient

Electrical Contd.Electrical Contd.Electrical Contd.Electrical Contd.Electrical Contd.

Works…..KIADB Indl. Estate, Hebbal, Hootagalli, Mysore-570018. Ph: (0821) 402561. Fax: (0821) 402172.◆ New Delhi: Ph: (011) 25177883. Fax: (011) 25438624 ◆ Bangalore: Ph: (080) 5587825. Fax: (080) 5596397 ◆ Kolkata: Ph:(033) 22823302.

Fax: (033) 22821025 ◆ Chandigarh: Ph:(0172) 370131. Fax:(0172) 792764 ◆ Mumbai: Ph:(022) 28581634. Fax:(022) 28582020◆ Chennai: Ph:(044) 28462055 Fax: (044) 28462102.

LARSEN & TOUBRO LIMITEDMETERING AND PROTECTION SYSTEMS

Product improvement is a continuous process. For the latest information, please contact any of our offices as listed aboveVisit us at www.lntmps.com