tms 114 and tms 114t technical manual r manual... · 2019. 7. 23. · aama 2605-05 - voluntary...

38
TMS 114/114T JULY 2019 www.pittcometals.com ARCHITECTURAL METALS, INC. TMS 114 AND TMS 114T TECHNICAL MANUAL

Upload: others

Post on 07-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

TMS 114/114T

JULY 2019 www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114 AND TMS 114TTECHNICAL MANUAL

AutoCAD SHX Text
R
Page 2: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

BLANK PAGE

AutoCAD SHX Text
R
Page 3: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

FEATURES

APPLICATIONS

· TMS 114 (non-thermal) and 114T (thermal barrier) are center set flush glazedsystems that are 4 1/2" deep with a 2" wide sightline

· Glaze from the outside or inside· Screw spline or shear block fabrication· Glazing options up to 1-1/8" thick· Available in anodized and standard or custom painted finishes· Readily available from stock

· Storefront, Punched Openings, or Ribbon Windows· Single span· Integrated entrance framing to allow Pittco standard entrances

or other speciality entrances to be incorporated

SYSTEM PERFORMANCE (TMS 114 Non-Thermal)Description Test Method Allowed Achieved Test Report

Structural ASTM E 330 30 psfAir ASTM E 283 0.06 cfm/ft2 @ 1.57 psf 0.014 cfm/ft2 @ 6.24 psf

Water (Static) ASTM E 331AAMA 501.1

None @ 10 psfNone @ 10 psf

None @ 10 psfNone @ 10 psf

CRF AAMA 1503 N/A 34* 17-02U Value AAMA 1503

NFRC 100N/AN/A

0.82*0.62*

17-0220-01

CR NFRC 500 19* 20-01N/A

N/A

FOR SPECIFIC PRODUCT APPLICATIONS PLEASE CONTACT YOUR PITTCO REPRESENTATIVE

SYSTEM PERFORMANCE (TMS 114T Thermal)Description Test Method Allowed Achieved Test Report

Structural ASTM E 330 30 psfAir ASTM E 283 0.06 cfm/ft2 @ 1.57 psf 0.014 cfm/ft2 @ 1.57 psf

ASTM E 331AAMA 501.1

None @ 10 psfNone @ 10 psf

None @ 10 psfNone @ 12 psf

CRF AAMA 1503 N/A 58* 19-02U Value AAMA 1503

NFRC 100N/AN/A

0.59*0.57*

19-0219-04

SHGC NFRC 200 0.62* 19-04N/A

N/A

* 1" IGU (1/4-1/2-1/4) Clear Annealed Glass, Air Filled, Aluminum Spacer.

Water (Dynamic)

U ValueSHGC NFRC 200 0.62* 20-01N/A

Water (Static)Water (Dynamic)

U Value

CR NFRC 500 N/A 31* 19-04

19-1219-12

19-1219-12

19-1219-12

19-1220-10

Air ASTM E 283 0.06 cfm/ft2 @ 6.24 psf 0.025 cfm/ft2 @ 6.24 psf 19-12

Air ASTM E 283 0.06 cfm/ft2 @ 6.24 psf 0.025 cfm/ft2 @ 6.24 psf 19-12

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

FEATURES

1

AutoCAD SHX Text
R
Page 4: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

SYSTEM PERFORMANCE (TMS 114T Thermal) cont.

CRF AAMA 1503 N/A 58+ 19-09U Value AAMA 1503

NFRC 100N/AN/A

0.40+0.39+

19-0919-07

SHGC NFRC 200 0.25+ 19-07N/A

+ 1" IGU (1/4 solarban 70xl, 1/2 argon filled space with high performance spacer, 1/4 clear glass).

U Value

CR NFRC 500 N/A 31+ 19-07

Description Test Method Allowed Achieved Test Report

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

BLANK PAGE

2

AutoCAD SHX Text
R
Page 5: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

EXPLODED VIEWS PAGE 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4 SIZE DETAILS - TMS 114 NON THERMAL PAGES D1 TO D4. . . . . . . . .

WINDLOAD CHARTS PAGES S1 TO S8. . . . . . . . . . . . . . . . . . . . . . . . . . . . DEADLOAD CHARTS PAGE S9. . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION PROPERTIES PAGE S10. . . . . . . . . . . . . . . . . . . . . . . . . .

1/4 SIZE DETAILS - TMS 114T THERMAL PAGES D5 TO D8. . . . . . . . . . . . ENTRANCE DETAILS PAGE D9. . . . . . . . . . . . . . . . . . . . . . . . . . . .

THERMAL CHARTS PAGES T1 TO T2. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PRODUCT DESCRIPTION - THERMAL PAGES 9 TO 13 . . . . . . . . . . . . . . .PRODUCT DESCRIPTION - NON THERMAL PAGES 4 TO 8 . . . . . . . . . . .

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

INDEX

3

AutoCAD SHX Text
R
Page 6: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

● BASIC USES / RELATED USESFraming is designed for flush, center glazed storefront assemblyVertical mullions are typically open back aluminum members, with solid face and flush closure plates forming tubular members for useon single spansHorizontal mullions are of hollow aluminum with removable glazing stopsCorners are configured for 90 and 135 degreesGlazing is insulating glass unit or single pane with adaptersGlass may be transparent, opaque, or decorative typesFraming is intended for one story applicationsFramed assembly may be fitted to most rigid and stable framed opening assemblies

● PRODUCT ATTRIBUTES AND CHARACTERISTICSFraming and glazing stops are designed for glass and panelsWind pressure resistance and pressure equalization are standard within the frame assemblyWeep containment and condensate water collection and drainage to the exterior at concealed weeps are standardIntegral door frames are available

● SELECTION CRITERIAQuality, economy, and good performance are provided at a reasonable costFraming is designed for Interior or exterior environments

● APPLICABLE STANDARDS, RELATED REFERENCESAA (Aluminum Association) - Designation System for Aluminum FinishesAAMA SFM-1-87 - Aluminum Storefront and Entrance ManualAAMA 501.1-05 - Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors using Dynamic PressureAAMA 611-98 - Voluntary Specification for Anodized Architectural AluminumAAMA 1503-98 - Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows,Doors, and Glazed Wall SectionsAAMA 2604-05 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings onAluminum Extrusions and PanelsAAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatingson Aluminum Extrusions and PanelsASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and PlateASTM B209M - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate [Metric]

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

NON-THERMAL PRODUCT DESCRIPTION

4

AutoCAD SHX Text
R
Page 7: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and TubeASTM B221M - Standard Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and Tube [Metric]ASTM E283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under SpecifiedPressure Differences Across the SpecimenASTM E330 - Standard Test Method for Structural Performance of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static AirPressure DifferenceASTM E331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air PressureDifference

● QUALITY, TESTS, CERTIFICATIONS, AND APPROVALSAir Infiltration: Maximum leakage of 0.02 cfm/sq ft. when measured in accordance with ASTM E283 at a test pressure of 6.24 psfStatic Water Leakage: No uncontrolled leakage, when measured in accordance with ASTM E331 at a test pressure difference of 12.0 psfDynamic Water Leakage: No uncontrolled leakage, when measured in accordance with AAMA 501.1 at a test pressure difference of 12.0 psfStructural Performance: Maximum deflection less than 1/175 of the span length and no damage to the assembly, when measured in accordancewith ASTM E330 at a test pressure of 25 psf

● PACKAGING, HANDLING, AND PROTECTION INSTRUCTIONSPackaged in specially designed heavy cartons or shipped pre-fabricated and assembled

● SPECIAL WARRANTYOne (1) year

● LIMITATIONSNot thermally brokenFraming is limited to applications of one story in heightNot intended for continuous members for multiple floor applications

● SAFETY PRECAUTIONSNormal precautions required

● AVAILABILITYFraming is available in all regions of USA - refer to Internet web site for locations and addresses of distributors

● COSTVaries with elevation, configuration and finish desired

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

NON-THERMALPRODUCT DESCRIPTION

5

AutoCAD SHX Text
R
Page 8: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

PRODUCT PROPERTIES● MATERIAL AND DESIGN

Aluminum: 6063-T6 alloy and temper, to ASTM B221 or ASTM B221MFasteners: Stainless steel, or zinc plated carbon steelPerimeter Anchors: Aluminum, or steel that will be isolated from aluminum componentsGlazing Gaskets: Wedge-type, Ethylene Propylene Diene Monomer (EPDM) rubber with non-stretch cordGlass Stops: Snap-in type

● SHAPE AND DIMENSIONSFrame Size: 2 x 4-1/2 inchGlass Edge Bite: 3/8 inchGlazing Thickness Accepted: 1/8 inch to 1-1/8 inch in increments of 1/16 inch except 7/16 inch, 9/16 inch, 11/16 inch, and 13/16 inch

● SHOP FABRICATION AND ASSEMBLYProvide for flush glazing on all sides with no projecting stopsConfigurations:■ Two-piece snap together mullions■ Solid tubular mullions, assembled to specially designed shear block clipsAccessories:■ Expansion Mullions■ Corner Mullions■ Open Back Perimeter Members■ Integral Door Frames■ Flashing, Subsills■ Head Receptor■ Heavy Duty Mullions■ Standard Steel Reinforcing Available

● COLORS AND TEXTURES■ Architectural anodic coating, in accordance with AAMA 611;

o Aluminum Association Designation.□ AA-M10C22A31 - Class II - (Pittco #42 Clear)□ AA-M10C22A41 - Class I - (Pittco #43 Clear)□ AA-M10C22A44 - Class I - (Pittco #59 Champagne)□ AA-M10C22A44 - Class I - (Pittco #60 Light Bronze)□ AA-M10C22A44 - Class I - (Pittco #61 Medium Bronze)□ AA-M10C22A44 - Class I - (Pittco #62 Dark Bronze)□ AA-M10C22A44 - Class I - (Pittco #63 Black)

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

NON-THERMAL PRODUCT DESCRIPTION

6

AutoCAD SHX Text
R
Page 9: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

■ Architectural organic coating, in accordance with AAMA 2604 (50% Kynar 500®);o Finish of Exposed Aluminum shall be compliant with the performance standards set forth in AAMA Specification 2604, High Performance

Organic Coatings on Aluminumo Type: Factory Applied, High Performance, 50% Polyvinylidene Fluoride (PVDF) Coating formulated by a licensed paint manufacturer, and

applied by Paint Manufacturer's Warranty-Approved Applicatoro Pretreatment: Applicator to pre-treat the aluminum with solutions to remove organic and inorganic surface soils, remove residual oxides,

followed by a Chrome Phosphate or Chromate Coating to ensure adhesion to the aluminumo Specify color code, e.g. UC 40577(Duranar Black)

■ Architectural organic coating, in accordance with AAMA 2605 (70% Kynar 500®);o Finish of Exposed Aluminum shall be compliant with the performance standards set forth in AAMA Specification 2605, Superior Performing

Organic Coatings on Aluminumo Type: Factory Applied, High Performance, 70% Polyvinylidene Fluoride (PVDF) Coating formulated by a licensed paint manufacturer, and

applied by Paint Manufacturer's Warranty-Approved Applicatoro Pretreatment: Applicator to pre-treat the aluminum with solutions to remove organic and inorganic surface soils, remove residual oxides,

followed by a Chrome Phosphate or Chromate Coating to ensure adhesion to the aluminumo Specify color code, e.g. UC 40577(Duranar Black)

PRODUCT PLACEMENT● PREPARATION WORK

Ensure openings are of proper size, and are plumb, square, level and in the proper location and alignment

● INSTALLATIONAlign installed assembly plumb and level, free of warp or twistMaintain dimensional tolerances, aligning with adjacent workSeal joints between framing and building structure watertightFollow guidelines in Pittco Fabrication, Sealant and Erection Brochure

● START-UP AND OPERATIONNot Applicable

● OWNER'S MAINTENANCE INSTRUCTIONSWash surfaces with warm water and mild soap; wipe clean, at least once a year

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

NON-THERMALPRODUCT DESCRIPTION

7

AutoCAD SHX Text
R
Page 10: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

Corporate IdentificationPittco Architectural Metals, Inc

1530 Landmeier RoadElk Grove Village, Illinois 60007Tel: (847) 593-3131Fax: (847) 593-9946Toll-Free: (800) 992-7488Internet: http://www.pittcometals.comE-mail: [email protected]

Technical Services AvailableToll-Free: (800) 992-7488

Classification and FilingMasterFormat

Subset of Section 08410 - Metal Framed StorefrontsUniFormat

Section B2030 - (exterior entrance frames) or C1020 (interior entrance frames)

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

NON-THERMAL PRODUCT DESCRIPTION

8

AutoCAD SHX Text
R
Page 11: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

● BASIC USES / RELATED USESFraming is designed for flush, center glazed storefront assemblyVertical mullions are typically open back aluminum members, with solid face and flush closure side plates forming tubular members for use onsingle spansHorizontal mullions are of hollow aluminum with removable glazing stopsGlazing is insulating glass unit or single pane with adaptersCorners are available for 90 and 135 degreesGlass may be transparent, opaque, or decorative typesFraming is intended for one story applicationsFramed assembly may be fitted to most rigid and stable framed opening assemblies

● PRODUCT ATTRIBUTES AND CHARACTERISTICSAluminum frame members are thermally improvedFraming and glazing stops are designed for glass and panelsWind pressure resistance and pressure equalization are standard within the frame assemblyWeep containment and condensate water collection and drainage to the exterior at concealed weeps are standardIntegral door frames are available

● SELECTION CRITERIAQuality, economy, and good performance are provided at a reasonable costFraming is designed for Interior or exterior environments

● APPLICABLE STANDARDS, RELATED REFERENCESAA (Aluminum Association) - Designation System for Aluminum FinishesAAMA SFM-1-87 - Aluminum Storefront and Entrance ManualAAMA 501.1-05 - Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors using Dynamic PressureAAMA 611-98 - Voluntary Specification for Anodized Architectural AluminumAAMA 1503-98 - Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors, and Glazed Wall SectionsAAMA 2604-05 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on AluminumExtrusions and PanelsAAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings onAluminum Extrusions and PanelsASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and PlateASTM B209M - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate [Metric]ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and TubeASTM B221M - Standard Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and Tube [Metric]

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

NON-THERMALPRODUCT DESCRIPTION

9

AutoCAD SHX Text
R
Page 12: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

ASTM E283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under SpecifiedPressure Differences Across the SpecimenASTM E330 - Standard Test Method for Structural Performance of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static AirPressure DifferenceASTM E331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air PressureDifference

● QUALITY, TESTS, CERTIFICATIONS, AND APPROVALS

Air Infiltration: Maximum leakage of 0.02 cfm/sq ft. when measured in accordance with ASTM E283 at a test pressure of 6.24 psfStatic Water Leakage: No uncontrolled leakage, when measured in accordance with ASTM E331 at a test pressure difference of 12.0 psfDynamic Water Leakage: No uncontrolled leakage, when measured in accordance with AAMA 501.1 at a test pressure difference of 12.0 psfStructural Performance: Maximum deflection less than 1/175 of the span length and no damage to the assembly, when measured in accordancewith ASTM E330 at a test pressure of 25 psfCondensation Resistance Factor (CRF): 58 when measured in accordance with AAMA 1503 with clear 1” insulated glass unit (1/4, 1/2, 1/4)Insulation U-Factor: 0.59 BTU/hr/sq ft/degrees F when measured in accordance with AAMA 1503 with clear 1” insulated glass unit (1/4, 1/2,1/4)

● PACKAGING, HANDLING, AND PROTECTION INSTRUCTIONSPackaged in specially designed heavy cartons or shipped pre-fabricated and assembled

● SPECIAL WARRANTYOne (1) year

● LIMITATIONSFraming is limited to applications of one story in heightNot intended for continuous members for multiple floor applications

● SAFETY PRECAUTIONSNormal precautions required

● AVAILABILITYFraming is available in all regions of USA - refer to Internet web site for locations and addresses of distributors

● COSTVaries with elevation, configuration and finish desired

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

THERMAL PRODUCT DESCRIPTION

10

AutoCAD SHX Text
R
Page 13: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

PRODUCT PROPERTIES● MATERIAL, COMPOSITION AND DESIGN

Aluminum: 6063-T6 alloy and temper, to ASTM B221 or ASTM B221MFasteners: Stainless steel, or zinc plated carbon steelPerimeter Anchors: Aluminum, or steel that will be isolated from aluminum componentsGlazing Gaskets: Wedge-type, Ethylene Propylene Diene Monomer (EPDM) rubber with non-stretch cordGlass Stops: Snap-in typeThermal Barrier: Poured and Debridged Polyurethane and Thermal Slots

● SHAPE AND DIMENSIONSFrame Size: 2 x 4-1/2 inchGlass Edge Bite: 3/8 inchGlazing Thickness Accepted: 1/8 inch to 1-1/8 inch in increments of 1/16 inch except 7/16 inch, 9/16 inch, 11/16 inch, and 13/16 inch

● SHOP FABRICATION AND ASSEMBLYProvide for flush glazing on all sides with no projecting stopsConfigurations:■ Two-piece snap together mullions■ Solid tubular mullions, assembled to specially designed shear block clipsAccessories:■ Expansion Mullions■ Corner Mullions■ Open Back Perimeter Members■ Integral Door Frames■ Flashing, Subsills■ Head Receptor■ Heavy Duty Mullions■ Standard Steel Reinforcing Available

● COLORS AND TEXTURES■ Architectural anodic coating, in accordance with AAMA 611;

o Aluminum Association Designation.□ AA-M10C22A31 - Class II - (Pittco #42 Clear)□ AA-M10C22A41 - Class I - (Pittco #43 Clear)□ AA-M10C22A44 - Class I - (Pittco #59 Champagne)□ AA-M10C22A44 - Class I - (Pittco #60 Light Bronze)□ AA-M10C22A44 - Class I - (Pittco #61 Medium Bronze)□ AA-M10C22A44 - Class I - (Pittco #62 Dark Bronze)□ AA-M10C22A44 - Class I - (Pittco #63 Black)

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

THERMALPRODUCT DESCRIPTION

11

AutoCAD SHX Text
R
Page 14: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

■ Architectural organic coating, in accordance with AAMA 2605 (70% Kynar 500®);o Finish on exposed aluminum shall be compliant with the performance standards set forth in AAMA 2605, “Superior Performing Organic

Coatings on Aluminum”.o Type: Factory Applied - High Performance, 70% Polyvinylidene Fluoride (PVDF) coating based on Elf Atochem, Inc. Kynar 500® or

Ausimount USA, Inc. Hylar 5000® resin, formulated by a Licensed Paint Manufacturer and applied by the Paint Manufacturer's WarrantyApproved Applicator.

o Pre-treatment: Applicator to pre-treat the aluminum with solutions to remove Organic and Inorganic Surface Soils and Residual Oxides,followed by a Chrome Phosphate Conversion Coating, at a minimum 40 mg/sq ft to ensure adhesion of paint to aluminum.

o Specify color code, e.g. UC 40577(Duranar Black)

■ Architectural organic coating, in accordance with AAMA 2605 (70% Kynar 500®);o Finish on exposed aluminum shall be compliant with the performance standards set forth in AAMA 2604, “High Performance Organic

Coatings on Aluminum”.o Type: Factory Applied - High Performance, 50% Polyvinylidene Fluoride (PVDF) coating based on Elf Atochem, Inc. Kynar 500® or

Ausimount USA, Inc. Hylar 5000® resin, formulated by a Licensed Paint Manufacturer and applied by the Paint Manufacturer's WarrantyApproved Applicator.

o Pre-treatment: Applicator to pre-treat the aluminum with solutions to remove Organic and Inorganic Surface Soils and Residual Oxides,followed by a Chrome Phosphate Conversion Coating, at a minimum 40 mg/sq ft to ensure adhesion of paint to aluminum.

o Specify color code, e.g. UC 40577(Duranar Black)

PRODUCT PLACEMENT● PREPARATION WORK

Ensure openings are of proper size, and are plumb, square, level and in the proper location and alignment

● INSTALLATIONAlign installed assembly plumb and level, free of warp or twistMaintain dimensional tolerances, aligning with adjacent workSeal joints between framing and building structure watertightFollow guidelines in Pittco Fabrication, Sealant and Erection Brochure

● START-UP AND OPERATIONNot Applicable

● OWNER'S MAINTENANCE INSTRUCTIONSWash surfaces with warm water and mild soap; wipe clean, at least once a year

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

THERMAL PRODUCT DESCRIPTION

12

AutoCAD SHX Text
R
Page 15: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

Corporate IdentificationPittco Architectural Metals, Inc

1530 Landmeier RoadElk Grove Village, Illinois 60007Tel: (847) 593-3131Fax: (847) 593-9946Toll-Free: (800) 992-7488Internet: http://www.pittcometals.comE-mail: [email protected]

Technical Services AvailableToll-Free: (800) 992-7488

Classification and FilingMasterFormat

Subset of Section 08410 - Metal Framed StorefrontsUniFormat

Section B2030 - (exterior entrance frames) or C1020 (interior entrance frames)

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

THERMALPRODUCT DESCRIPTION

13

AutoCAD SHX Text
R
Page 16: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

HEAD

HORIZONTAL

GLASS STOP

SILL

GLASS STOP

OPEN BACK MULLION

SNAP-IN FILLER

SCREW SPLINE ASSEMBLY

SHEAR BLOCK ASSEMBLY

HEAD

HORIZONTAL

GLASS STOP

SILL

GLASS STOP

OPEN BACK MULLIONSNAP-IN FILLER

THE SCREW SPLINE SYSTEM ALLOWS A FRAME TO BE INSTALLED FROM UNITIZED ASSEMBLIES. SCREWS ARE DRIVENTHROUGH THE BACK OF THE VERTICALS INTO SPLINES EXTRUDED IN THE HORIZONTAL FRAMING MEMBERS. INDIVIDUALUNITS ARE THEN SNAPPED TOGETHER TO FORM A COMPLETE FRAME

THE SHEAR BLOCK METHOD OF FABRICATION IS AN ALTERNATE METHOD OF FABRICATION. HORIZONTALSARE ATTACHED TO THE VERTICAL MULLIONS WITH SHEAR BLOCKS. THIS METHOD MUST BE USED WITHTUBULAR VERTICAL MULLIONS.

SHEAR BLOCK

SHEAR BLOCK

SHEAR BLOCK

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

EXPLODED VIEW

14

AutoCAD SHX Text
R
Page 17: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

3

4

5

1 2

2"T

YP

ICA

L

412"

TYPICAL

2"T

YP

ICA

L

412"

TYPICAL

2"TYPICAL

41 2"

TY

PIC

AL

2"TYPICAL

41 2"

TY

PIC

AL

SCREW SPLINE SHEAR BLOCK

2VERTICAL

1JAMB

3HEAD

4HORIZONTAL

5SILL

2VERTICAL

1JAMB

3HEAD

4HORIZONTAL

5SILL

20-028 (JAMB)20-168 (PERIMETER FILLER)

20-028 (JAMB)20-029 (GLAZING FILLER)

20-028 (JAMB)20-168 (PERIMETER FILLER)

20-028 (JAMB)20-029 (GLAZING FILLER)

20-028 (HEAD)20-168 (PERIMETER FILLER)

20-039 (HORIZONTAL)19-031 (GLASS STOP)

20-030 (SILL)19-031 (GLASS STOP)20-168 (PERIMETER FILLER)20-000 (SUB-SILL)

20-028 (HEAD)20-168 (PERIMETER FILLER)19-034 (SHEAR BLOCK)

20-039 (HORIZONTAL)19-031 (GLASS STOP)19-040 (SHEAR BLOCK)

20-030 (SILL)19-031 (GLASS STOP)20-168 (PERIMETER FILLER)20-000 (SUB-SILL)19-041 (SHEAR BLOCK)

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

NON-THERMALTYPICAL FRAMING DETAILS (Outside Glazed)

D1DETAILS

AutoCAD SHX Text
R
Page 18: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

3

4

5

1 2

SCREW SPLINE SHEAR BLOCK

2"TYPICAL

41 2"

TY

PIC

AL

2"TYPICAL

41 2"

TY

PIC

AL

2"T

YP

ICA

L

412"

TYPICAL

2"T

YP

ICA

L

412"

TYPICAL

20-028 (JAMB)20-168 (PERIMETER FILLER)

20-028 (JAMB)20-029 (GLAZING FILLER)

20-028 (JAMB)20-168 (PERIMETER FILLER)

20-028 (JAMB)20-029 (GLAZING FILLER)

20-030 (HEAD)19-031 (GLASS STOP)20-168 (PERIMETER FILLER)

20-039 (HORIZONTAL)19-031 (GLASS STOP)

20-028 (SILL)20-168 (PERIMETER FILLER)20-000 (SUB-SILL)

20-030 (HEAD)19-031 (GLASS STOP)20-168 (PERIMETER FILLER)19-041 (SHEAR BLOCK)

20-039 (HORIZONTAL)19-031 (GLASS STOP)19-040 (SHEAR BLOCK)

20-028 (SILL)20-168 (PERIMETER FILLER)20-000 (SUB-SILL)19-034 (SHEAR BLOCK)

2VERTICAL

1JAMB

3HEAD

4HORIZONTAL

5SILL

2VERTICAL

1JAMB

3HEAD

4HORIZONTAL

5SILL

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

NON-THERMAL TYPICAL FRAMING DETAILS (Inside Glazed)

D2DETAILS

AutoCAD SHX Text
R
Page 19: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

412"

41 2"

16-705 19-047

2 PIECE NO POCKET CORNER 1 POCKET CORNER

19-047

20-043

19-047

20-042

20-043

20-04420-043

20-042

2 POCKET CORNER 90° CORNER 90° CORNER

20-042

20-043

3 POCKET CORNER 4 POCKET CORNER 135° CORNER

17-4

62

20-029

ADJUSTABLE MULLION

20-14020-141

19-047

20-043

20-042

20-029

412" x 41

2" TUBE

(ADJUSTABLE FROM 0 TO 90 DEGREES)

(SCREW SPLINE OR SHEAR BLOCK FABRICATION) (SHEAR BLOCK FABRICATION ONLY)

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

NON-THERMALCORNER DETAILS

D3DETAILS

AutoCAD SHX Text
R
Page 20: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

20-028

20-02916-500

20-139

20-029

20-038

20-032

19-04519-183 19-168

17-349

20-139

20-029

20-032

20-186

214"

19-102 20-101

19-152

20-095

20-029

19-03119-031

20-095

19-03119-031

20-097

STANDARD MULLION w/OPTIONAL STEEL

16-501

HEAVY WALL MULLION HEAVY WALL MULLIONw/

OPTIONAL STEEL

TUBULAR MULLION EXPANSION MULLION

14" SNAP IN

GLAZING ADAPTER

12" SNAP IN

GLAZING ADAPTER

FULL LENGTHFLAT FILLER

SNAP INPOCKET FILLER

SLIDE INDOOR STOP

HEAD RECEPTOR

412 " x 41

2" HORIZONTAL 412" SILL

16-142

OPTIONAL SILL FLASHINGS

NARROW SIDELITE BASE

30-105

17-021

30-18430-184

20-000

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

NON-THERMAL MISCELLANEOUS DETAILS

D4DETAILS

AutoCAD SHX Text
R
Page 21: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

3

4

5

1 2

2"T

YP

ICA

L

412"

TYPICAL

2"T

YP

ICA

L

412"

TYPICAL

41 2"

TY

PIC

AL

2"TYPICAL

41 2"

TY

PIC

AL

SCREW SPLINE SHEAR BLOCK

2VERTICAL

1JAMB

3HEAD

4HORIZONTAL

5SILL

2VERTICAL

1JAMB

3HEAD

4HORIZONTAL

5SILL

19-028 (JAMB)20-168 (PERIMETER FILLER)

19-028 (JAMB)19-029 (GLAZING FILLER)

19-028 (JAMB)20-168 (PERIMETER FILLER)

19-028 (JAMB)19-029 (GLAZING FILLER)

19-028 (HEAD)20-168 (PERIMETER FILLER)

19-039 (HORIZONTAL)19-031 (GLASS STOP)

19-030 (SILL)19-031 (GLASS STOP)20-168 (PERIMETER FILLER)19-000 (SUB-SILL)

19-028 (HEAD)20-168 (PERIMETER FILLER)19-034 (SHEAR BLOCK)

19-039 (HORIZONTAL)19-031 (GLASS STOP)19-040 (SHEAR BLOCK)

19-030 (SILL)19-031 (GLASS STOP)20-168 (PERIMETER FILLER)19-000 (SUB-SILL)19-041 (SHEAR BLOCK)

2"TYPICAL

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

THERMALTYPICAL FRAMING DETAILS (Outside Glazed)

D5DETAILS

AutoCAD SHX Text
R
Page 22: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

3

4

5

1 2

SCREW SPLINE SHEAR BLOCK

2"T

YP

ICA

L

412"

TYPICAL

2"T

YP

ICA

L

412"

TYPICAL

2"TYPICAL

41 2"

TY

PIC

AL

2"TYPICAL

41 2"

TY

PIC

AL

19-028 (JAMB)20-168 (PERIMETER FILLER)

19-028 (JAMB)19-029 (GLAZING FILLER)

19-028 (JAMB)20-168 (PERIMETER FILLER)

19-028 (JAMB)20-029 (GLAZING FILLER)

19-030 (HEAD)19-031 (GLASS STOP)20-168 (PERIMETER FILLER)

19-039 (HORIZONTAL)19-031 (GLASS STOP)

19-028 (SILL)20-168 (PERIMETER FILLER)19-000 (SUB-SILL)

19-030 (HEAD)19-031 (GLASS STOP)20-168 (PERIMETER FILLER)19-041 (SHEAR BLOCK)

19-039 (HORIZONTAL)19-031 (GLASS STOP)19-040 (SHEAR BLOCK)

19-028 (SILL)20-168 (PERIMETER FILLER)19-000 (SUB-SILL)19-034 (SHEAR BLOCK)

2VERTICAL

1JAMB

3HEAD

4HORIZONTAL

5SILL

2VERTICAL

1JAMB

3HEAD

4HORIZONTAL

5SILL

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

THERMAL TYPICAL FRAMING DETAILS (Inside Glazed)

D6DETAILS

AutoCAD SHX Text
R
Page 23: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

412"

41 2"

16-705 19-047 19-047

19-043

19-047

19-042

19-043

19-04419-043

19-042

19-042

19-043

19-4

62

19-029

19-14019-141

19-047

19-043

19-042

19-029

2 PIECE NO POCKET CORNER 1 POCKET CORNER

2 POCKET CORNER 90° CORNER 90° CORNER

3 POCKET CORNER 4 POCKET CORNER 135° CORNER

ADJUSTABLE MULLION

412" x 41

2" TUBE

(ADJUSTABLE FROM 0 TO 90 DEGREES)

(SCREW SPLINE OR SHEAR BLOCK FABRICATION) (SHEAR BLOCK FABRICATION ONLY)

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

THERMALCORNER DETAILS

D7DETAILS

AutoCAD SHX Text
R
Page 24: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

19-028

19-029

19-139

19-029

19-038

19-032

19-04519-183 19-168

17-349

19-032

19-029

214"

19-102 19-101

19-152 16-142

19-095

19-029

19-03119-031

19-095

19-03119-031

19-097

19-139

* NARROW SIDELITE BASE IS NON-THERMAL*

STANDARD MULLION w/OPTIONAL STEEL

HEAVY WALL MULLION HEAVY WALL MULLIONw/

OPTIONAL STEEL

TUBULAR MULLION EXPANSION MULLION

14" SNAP IN

GLAZING ADAPTER

12" SNAP IN

GLAZING ADAPTER

FULL LENGTHFLAT FILLER

SNAP INPOCKET FILLER

HEAD RECEPTOR

412 " x 41

2" HORIZONTAL 412" SILL NARROW SIDELITE BASE

16-50016-501

OPTIONAL SILL FLASHINGS

30-105

17-021

30-18430-184

19-000

20-186

SLIDE INDOOR STOP

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

THERMAL MISCELLANEOUS DETAILS

D8DETAILS

AutoCAD SHX Text
R
Page 25: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

2"T

YP

ICA

L

412"

TYPICAL1

TRANSOM HEAD

2DOOR HEAD

3BOTTOM RAIL

19-030 (HEAD)19-031 (GLASS STOP)20-168 (PERIMETER FILLER)

19-130 (TRANSOM HEAD)19-131 (SHEAR BLOCK)

SINGLE ACTING

1

2

3

76

54

10

3

98

DOUBLE ACTING

SINGLE ACTINGDOOR JAMBS

DOUBLE ACTINGDOOR JAMBS

41 2"

TY

PIC

AL

10SINGLE ACTING

HEADER

10DOUBLE ACTING

HEADER

619-036 OR 19-177

(MULLION)w/ 19-099 (TRANSOM INSERT)

TRANSOM JAMBSTransom area for both double or single acting doors withglass surround. Jambs above transom bar are routed outto accept glass holding insert with or without steel reinforcing.

19-130 (TRANSOM HEAD)19-131 (SHEAR BLOCK)

819-177 (MULLION)

919-177 (MULLION)

419-036 (MULLION)

519-036 (MULLION)

719-036 OR 19-177

(MULLION)w/ 19-099 (TRANSOM INSERT)

12-140 (TRANSOM HEAD)19-131 (SHEAR BLOCK)14-090 (SASH)

12-140 (TRANSOM HEAD)19-131 (SHEAR BLOCK)

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

ENTRANCE DETAILS

D9DETAILS

AutoCAD SHX Text
R
Page 26: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

BLANK PAGE

D10

AutoCAD SHX Text
R
Page 27: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

SYSTEM ANALYSIS CRITERIA:

DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"

CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"

L/175 FOR SPANS LESS THAN 13'-6"

LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)

SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION

ALUMINUM: 6063-T6

(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)

20-02820-029

A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF

20-02820-029

WITH 16-500 STEEL

VERTICAL REINFORCING IS ANALYZED AS AN ASSEMBLY WITH THE ALUMINUMSECTIONS.

A

B

CD

E

A

B

C

D

E

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

NON-THERMALWINDLOAD CHARTS

S1

AutoCAD SHX Text
R
Page 28: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

20-13920-029

20-13920-029

WITH 16-501 STEEL

VERTICAL REINFORCING IS ANALYZED AS AN ASSEMBLY WITH THE ALUMINUMSECTIONS.

A

BCD

E

A

B

C

D

E

A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF

SYSTEM ANALYSIS CRITERIA:

DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"

CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"

L/175 FOR SPANS LESS THAN 13'-6"

LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)

SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION

ALUMINUM: 6063-T6

(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

NON-THERMAL WINDLOAD CHARTS

S2

AutoCAD SHX Text
R
Page 29: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

SYSTEM ANALYSIS CRITERIA:

DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"

CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"

L/175 FOR SPANS LESS THAN 13'-6"

LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)

SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION

ALUMINUM: 6063-T6

(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)

20-038

20-03220-032

COMBINED SECTIONS ARE ANALYZED AS AN ASSEMBLY

A

BCD

E

A

B

C

D

E

A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

NON-THERMALWINDLOAD CHARTS

S3

AutoCAD SHX Text
R
Page 30: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

19-02819-029

19-02819-029

WITH 16-500 STEEL

VERTICAL REINFORCING IS ANALYZED AS AN ASSEMBLY WITH THE ALUMINUMSECTIONS.

A

B

CD

E

A

B

C

D

E

SYSTEM ANALYSIS CRITERIA:

DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"

CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"

L/175 FOR SPANS LESS THAN 13'-6"

LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)

SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION

ALUMINUM: 6063-T6

(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)

A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF

A 15% REDUCTION IN SECTION PROPERTIES TO ACCOUNT FOR THERMAL BREAK

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

THERMAL WINDLOAD CHARTS

S4

AutoCAD SHX Text
R
Page 31: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

19-13919-029

19-13919-029

WITH 16-501 STEEL

VERTICAL REINFORCING IS ANALYZED AS AN ASSEMBLY WITH THE ALUMINUMSECTIONS.

A

B

CD

E

A

B

C

D

E

SYSTEM ANALYSIS CRITERIA:

DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"

CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"

L/175 FOR SPANS LESS THAN 13'-6"

LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)

SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION

ALUMINUM: 6063-T6

(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)

A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF

A 15% REDUCTION IN SECTION PROPERTIES TO ACCOUNT FOR THERMAL BREAK

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

THERMALWINDLOAD CHARTS

S5

AutoCAD SHX Text
R
Page 32: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

19-038

19-03219-032

COMBINED SECTIONS ARE ANALYZED AS AN ASSEMBLY

A

BCD

E

A

B

C

D

E

SYSTEM ANALYSIS CRITERIA:

DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"

CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"

L/175 FOR SPANS LESS THAN 13'-6"

LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)

SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION

ALUMINUM: 6063-T6

(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)

A 15% REDUCTION IN SECTION PROPERTIES TO ACCOUNT FOR THERMAL BREAK

A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

THERMAL WINDLOAD CHARTS

S6

AutoCAD SHX Text
R
Page 33: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

19-036

SYSTEM ANALYSIS CRITERIA:

DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"

CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"

L/175 FOR SPANS LESS THAN 13'-6"

LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)

SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION

ALUMINUM: 6063-T6

(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)

A 15% REDUCTION IN SECTION PROPERTIES TO ACCOUNT FOR THERMAL BREAK

A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF

A

B

CD

E

19-03616-500

VERTICAL REINFORCING IS ANALYZED AS AN ASSEMBLY WITH THE ALUMINUMSECTIONS.

A

B

C

D

E

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

WINDLOAD CHARTS

S7

AutoCAD SHX Text
R
Page 34: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

19-177

SYSTEM ANALYSIS CRITERIA:

DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"

CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"

L/175 FOR SPANS LESS THAN 13'-6"

LATERAL BRACING OR HORIZONTAL MEMBER SPACING: 48" O.C. (MAXIMUM)

SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION

ALUMINUM: 6063-T6

(FOR HORIZONTAL SPACING GREATER THAN 48" CONTACT PITTCO ENGINEERING)

A 15% REDUCTION IN SECTION PROPERTIES TO ACCOUNT FOR THERMAL BREAK

A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF

A

B

CD

E

19-17716-500

VERTICAL REINFORCING IS ANALYZED AS AN ASSEMBLY WITH THE ALUMINUMSECTIONS.

A

B

C

D

E

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

WINDLOAD CHARTS

S8

AutoCAD SHX Text
R
Page 35: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

20-039 (HORIZONTAL)19-031 (GLASS STOP)

20-030 (HORIZONTAL)20-029 (GLAZING FILLER)19-031 (GLASS STOP)

19-039 (HORIZONTAL)19-031 (GLASS STOP)

19-030 (HORIZONTAL)19-029 (GLAZING FILLER)19-031 (GLASS STOP)

A = SETTING BLOCKS AT 1/8 POINTSB = SETTING BLOCKS AT 1/4 POINTS

SYSTEM ANALYSIS CRITERIA:

SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION

ALUMINUM: 6063-T6

A 15% REDUCTION IN SECTION PROPERTIES TO ACCOUNT FOR THE THERMAL BREAK THERMAL SECTIONS

HORIZONTAL OR DEADLOAD LIMITATIONS ARE BASED UPON 1/8" MAXIMUM ALLOWABLE DEFLECTION WITH 1" THICK INSULATED GLASS

AB

AB

AB

AB

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

DEADLOAD CHARTS

S9

AutoCAD SHX Text
R
Page 36: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

STRUCTURAL PROPERTIES of TMS 114 NON-THERMAL FRAMINGPart Number Ix Sx Iy Sy

12-140 3.993 1.774 1.102 1.10216-500 (Steel) 1.093 0.547 0.024 0.04216-501 (Steel) 0.649 0.316 0.032 0.076

16-705 6.984 3.104 6.984 3.10417-462 3.511 1.145 1.667 0.65419-036 3.380 1.470 0.887 0.62819-047 1.881 0.563 1.947 0.59619-130 4.047 1.795 1.050 0.74419-177 3.412 1.508 0.846 0.79220-028 2.804 1.196 0.404 0.31520-030 2.133 0.822 0.296 0.27420-032 2.257 1.001 0.164 0.16620-038 3.000 1.325 0.679 0.66920-039 2.445 1.021 0.458 0.38920-042 2.287 0.756 2.274 0.73720-043 2.338 0.764 1.847 0.56520-044 2.333 0.775 1.809 0.54320-095 4.630 2.059 2.163 0.96420-139 6.688 2.889 0.663 0.56920-140 1.869 0.810 0.074 0.08520-141 2.138 0.877 0.180 0.133

STRUCTURAL PROPERTIES of TMS 114T THERMAL BARRIER FRAMINGPart Number Ix Sx Iy Sy

19-029 0.649 0.316 0.032 0.07619-036 3.380 1.470 0.887 0.62819-047 1.881 0.563 1.947 0.59619-028 2.084 1.196 0.404 0.31519-030 2.133 0.822 0.296 0.27419-032 2.257 1.000 0.163 0.16619-038 2.995 1.321 0.678 0.66819-039 2.445 1.021 0.458 0.38919-042 2.287 0.756 2.274 0.73719-043 2.338 0.764 1.847 0.56519-044 2.333 0.775 1.809 0.54319-095 4.630 2.059 2.163 0.96419-139 6.688 2.889 0.663 0.56919-140 1.869 0.810 0.074 0.08519-141 2.138 0.877 0.180 0.13319-168 0.508 0.243 0.012 0.01519-177 3.412 1.508 0.846 0.79219-462 3.511 1.145 1.667 0.654

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

SECTION PROPERTIES

S8

AutoCAD SHX Text
R
Page 37: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

THERMAL CHARTS

T1FOR INSTRUCTIONS ON HOW TO READ THERMAL CHARTS PLEASE SEE GENERAL SECTION OF THE CATALOG

AutoCAD SHX Text
R
Page 38: TMS 114 AND TMS 114T TECHNICAL MANUAL R Manual... · 2019. 7. 23. · AAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing

www.pittcometals.com

ARCHITECTURAL METALS, INC.

TMS 114/114T

JULY 2019

TMS 114/114T

JULY 2019

THERMAL CHARTS

T2FOR INSTRUCTIONS ON HOW TO READ THERMAL CHARTS PLEASE SEE GENERAL SECTION OF THE CATALOG

AutoCAD SHX Text
R