TONGUE & GROOVE INSTALLATION INSTRUCTIONS PREPARATION Apply NuCedar products over a properly installed weather resistant barrier (ex. House Wrap) and ensure all wall openings and penetrations are properly flashed in accordance with local building codes and window/door manufacturer’s flashing recommendations. The NuCedar cladding system is not a water-tight barrier. It is designed to reduce the amount of water that reaches the underlying weather resistant barrier. All forms of NuCedar Vertical Siding must be installed over a continuous, flat surface capable of supporting the use of screws that will restrict temperature related expansion and contraction of the siding (Ex. OSB or Plywood). NuCedar Vertical Siding cannot be installed over open framing or furring strips. FASTENING A scarf joint is best for joints, or you can Z-Flash with color matched coil stock All required fasteners are included with your siding order Regardless of board length, make sure to use an extra screw in the center as shown below DO NOT DRAG COULD SCRATCH MATERIAL DO NOT INSTALL IMPROPERLY COLORED BOARDS DO NOT COVER WITH DARK MATERIAL DO NOT STORE WHERE TEMPERATURES MAY EXCEED 120 0 FASTEN USE SUPPLIED STARBORN PRO PLUG SCREWS, OR EXTERIOR #6 OR #8 SCREWS PLAN LAYOUT PRIOR TO INSTALLATION CUT USING STANDARD WOODWORKING TOOLS Along the length: Fasteners no farther apart than 16" Use additional fasteners in center as shown Exactly 2" from the end of the board 2" 2" 16" 16" 16" 16" 16" 16" 5” FACE 6 ” FACE FASTENER PLACEMENT HOUSE WRAP 16" 2" 2" HORIZONTAL INSTALLATION FASTENER PLACEMENT HOUSE WRAP 2" 2" VERTICAL INSTALLATION 16" INSTALL SIDING OVER SOLID SHEATHING SUCH AS PLYWOOD OR OSB SCARF JOINT CUT 450 JOIN WITH FASTENERS AND ADHESIVE NORTHEAST REGION: PHONE: (800)526-4708 SOUTHEAST REGION: PHONE: (800)296-0288 WWW.GARDENSTATELUMBER.COM

Upload: others

Post on 15-Jul-2020

19 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TONGUE & GROOVE...TONGUE & GROOVE INSTALLATION INSTRUCTIONS J Corner: Siding slides under corner Keep 1/16” gap between corner and siding No gap needed for vertical application Standard

TONGUE & GROOVE I N S T A L L A T I O N I N S T R U C T I O N S

P R E P A R AT I O NApply NuCedar products over a properly installed weather resistant barrier (ex. House Wrap) and ensure all wall openings and penetrations are properly flashed in accordance with local building codes and window/door manufacturer’s flashing recommendations. The NuCedar cladding system is not a water-tight barrier. It is designed to reduce the amount of water that reaches the underlying weather resistant barrier. All forms of NuCedar Vertical Siding must be installed over a continuous, flat surface capable of supporting the use of screws that will restrict temperature related expansion and contraction of the siding (Ex. OSB or Plywood). NuCedar Vertical Siding cannot be installed over open framing or furring strips.

FA S T E N I N G ■ A scarf joint is best for joints, or you can

Z-Flash with color matched coil stock ■ All required fasteners are included with

your siding order ■ Regardless of board length, make sure to use

an extra screw in the center as shown below

DO NOT DRAG

COULD SCRATCH MATERIAL

DO NOT INSTALL

IMPROPERLY COLORED BOARDS

DO NOT COVER

WITH DARK MATERIAL

DO NOT STORE

WHERE TEMPERATURES MAY EXCEED 1200

FASTENUSE SUPPLIED STARBORN PRO PLUG®️

SCREWS, OR EXTERIOR #6 OR #8 SCREWS

PLANLAYOUT PRIOR

TO INSTALLATION

CUTUSING STANDARD

WOODWORKING TOOLS

Along the length: Fasteners no farther

apart than 16"

Use additional fasteners in center

as shown

Exactly 2" from the end of the board

2"

2"

16"

16"

16"

16"

16"

16"

5” FACE 6 3/4” FACE

FASTENER PLACEMENT

HOUSE WRAP

16"

2"

2"

HORIZONTAL INSTALLATION

FASTENER PLACEMENT

HOUSE WRAP

2"

2"

VERTICAL INSTALLATION

16"

INSTALL SIDING OVER SOLID

SHEATHING SUCH AS PLYWOOD

OR OSB

SCARF JOINT

CUT 450

JOIN WITH FASTENERS AND ADHESIVE

NORTHEAST REGION:

PHONE: (800)526-4708SOUTHEAST REGION:

PHONE: (800)296-0288

WWW.GARDENSTATELUMBER.COM

Page 2: TONGUE & GROOVE...TONGUE & GROOVE INSTALLATION INSTRUCTIONS J Corner: Siding slides under corner Keep 1/16” gap between corner and siding No gap needed for vertical application Standard

INSTALLATION MUST FOLLOW THE INSTRUCTIONS IN THIS MANUAL TO MAINTAIN PRODUCT WARRANTY

In order to secure your warranty, please visit our website to register your product: gardenstatelumber.com/NuCedar/technical/warranty/ For additional copies and

revisions, go to gardenstatelumber.com/NuCedar.

CORNER INSTALLATION OPTIONS

T O U C H - U P A N D R E - P A I N T I N GALL TOUCH UP PAINT MUCH BE SHAKEN VIGOROUSLY TO ENSURE COLOR MATCHES. Apply touch-up paint on all cuts, planed edges and small damaged areas. NuCedar can be touched up with a high-grade exterior latex paint. NuCedar recommends PPG MANOR HALL® Exterior 100% Acrylic Latex Paint. In the future, if you would like to repaint the product, it is possible to do; however, you will void your warranty going forward. For re-painting, use a high-grade exterior latex paint, such as PPG Manor Hall (Exterior, Satin Finish). Make sure that your paint color has a Light Reflective Value (LRV) of 55 units or greater. Prior to touching up or repainting, make sure that the surface area is properly cleaned and prepared according to manufacturer’s specifications.

C A R E A N D M A I N T E N A N C ENuCedar products can be safely cleaned using a mixture of water and mild detergent or a mild household cleaner. Remove mold/mildew using a mild commercial mold/mildew remover. NuCedar can be lightly sprayed or cleaned with a house brush (high pressure power-washers could destroy the Rough Sawn texture) to remove dust and debris. Refer to manufacturer’s instructions.

TONGUE & GROOVE I N S T A L L A T I O N I N S T R U C T I O N S

J Corner: Siding slides under corner

Keep 1/16” gap between corner and siding

No gap needed for vertical application

Standard Corner: Siding butts to edges

Keep 1/16” gap between corner and siding

No gap needed for vertical application

Mitered Corner: Cut at 45 degrees

Screws exactly 2” from the end of the board

Stacked Corner: Overlap corner of wall by 5/8”, butt in piece from adjoining wall

H O R I Z O N TA L A P P L I C AT I O N V E R T I C A L A P P L I C AT I O N

Use Fill & Flex, Fast Cure, or consult a Representative for other options

J CORNER

MITERED CORNER

STACKED CORNER

OR

STANDARD CORNER

2” 2”

2” 2”

1/16"

1/16"

NORTHEAST REGION:

PHONE: (800)526-4708SOUTHEAST REGION:

PHONE: (800)296-0288

WWW.GARDENSTATELUMBER.COM