AEQUALIS ASCEND™ FLEXConvertible Shoulder System
W E E X P E C T M O R E T H A N O T H E R S T H I N K I S P O S S I B L E .
AEQUALIS ASCEND™ FLEXConvertible Shoulder System
AEQUALIS™ REV IIThreaded Post Baseplate
AEQUALIS™ PERFORM™
Glenoid System
Preservation. Fixation. Performance. Conversion.
W E E X P E C T M O R E T H A N O T H E R S T H I N K I S P O S S I B L E .
Fixation and Conversion.
FixationANATOMICALLY DERIVED STEM DESIGN Mimics the internal humeral geometry to maximize proximal fixation.
PLASMA SPRAY COATING Creates immediate and long-term fixation.
ConversionCONVERTIBLE DESIGN Simply adapts from anatomic to reverse without stem removal.
SHORT STEM & COLLARLESS DESIGN Simplify stem removal, when needed.
Fixation and Performance.
FixationCENTRAL THREADED POST Provides immediate baseplate fixation.
PLASMA SPRAY COATING Creates long-term baseplate fixation.
VARIABLE LOCKING SCREWS Enhance baseplate fixation.
Performance 145° INCLINATION Optimizes range of motion & reduces notching.
ECCENTRIC REVERSED TRAYS Adjust for variation in stem placement & simplify conversion.
LATERALIZED GLENOID OPTIONS Decrease scapular notching.
Bone Preservation.
Excessive ReamingARTHRITIC VARIABILITYArthritic glenoid articular curvatures are 22% flatter and have 3X more variance than non-arthritic glenoids.1
TRADITIONAL REAMERSTraditional reamer curvatures were derived from non-arthritic cadaveric specimens.
CLINICAL OUTCOMESExcessive reaming to achieve backside fit with traditional reamers is a leading cause in long-term glenoid loosening.2,3
PreservationMULTIPLE CURVATURES PER SIZEReamers and implants adapt to arthritic anatomy preserving subchondral bone and structural integrity.
Glenoid Curvature
AEQUALIS™ PERFORM™ Glenoids
Traditional GlenoidsCurved
Glenoid
Flat Glenoid
Glenoid Curvature Comparison
Glenoid Reaming Comparison
In our data collection, 75% of arthritic glenoids had an articular radius curvature that fell outside of 30-35mm, and 50% fell outside of 30-40mm.1
Glenoid Sample
Preserve up to 68% more bone when compared to traditional glenoid systems.1
Volume Reamed
(mm3)
TRADITIONAL REAMER
AEQUALIS™ PERFORM™ REAMER
30 mm
35 mm X
40 mm X
50 mm X
60 mm X
Press-Fit Cemented
88-125 mm 88-120 mm66-94 mm 66-90 mm
Low Offset
High Offset
Stem Options
AEQUALIS ASCEND™ FLEX Stems
1 2 3 4 5 6 7 8
Heads Reversed Trays
Centered
Low Offset
High Offset
SM
15 mm
Diameter 25 mm
Centralized Lateralized Eccentric
Diameter 29 mm
25 mm
30 mm
35 mm
MED
LG
XL
30 mm 35 mm 40 mm 50 mm 60 mm
AEQUALIS™ PERFORM™ Glenoid REVERSED Glenoid
CORTILOC™Pegged Keeled
™ and ® denote Trademarks and Registered Trademarks of Wright Medical Group N.V., or its affiliates.©2016 Wright Medical Group N.V. or its affiliates. All Rights Reserved.
CAW-6546 REV B ECN 160222 08-Feb-2016
10801 Nesbitt Avenue SouthBloomington, MN 55437888 867 6437952 426 7600www.tornier.com
1023 Cherry RoadMemphis, TN 38117800 238 7117901 867 9971www.wright.com
References1. Tornier Data on File.2. Gilles Walch, MD; Allan A. Young, MD; Pascal Boileau, MD; Markus Loew, MD; Dominique Gazielly, MD and Daniel Molé, MD. Patterns of Loosening of Polyethylene
Keeled Glenoid Components After Shoulder Arthroplasty for Primary Osteoarthritis. Results of a Multicenter Study with More than Five Years of Follow-up.3. Gilles Walch, MD; Allan A Young, MD; Barbara Melis, MD; Dominique Gazielly, MD; Markus Loew, MD; Pascal Boileau, MD. Results of a Convex-back Cemented
Keeled Glenoid Component in Primary Osteoarthritis: Multicenter Study with a Follow-up Greater than 5 Years.