SENTINEL PEDESTAL CONTROLLERPS2 STAINLESS STEEL ENCLOSURE
TORO-IRRIGATION DIVISION5825 JASMINE STREETRIVERSIDE, CA 92504TOLL FREE: 1-877-345-8676FAX: (951) 359-1870www.toro.com
REVISION DATE 04-10-2019
NOT TO SCALE NOT TO SCALE
FRONTSECTION/ELEVATION
RIGHT-SIDESECTION/ELEVATION
TORO SENTINEL TOP ENTRYIRRIGATION CONTROLLERMODEL NO. SB[XX]PS2U (CONVENTIONAL)OR SBW[XX]PS2U (WIRELESS)SEE PLAN FOR NUMBER OF STATIONS
2" CONDUIT FOR FIELD WIRESUP TO 24 STATIONS
3/4'' CONDUIT FOR GROUND
3/4'' CONDUIT FOR INPUT POWER PERLOCAL & NATIONAL ELECTRICAL CODES
OPTIONAL 2'' CONDUIT FOR ADDITIONALFIELD WIRES (25 - 48)
FINISHED SURFACE SLOPE TO DRAIN
CONCRETE FOOTING
1/2" CONDUIT FOR SENSOR WIRES
STANDARD 400MHZ ANTENNA FORPRIMARY COMMUNICATION
NOTES:1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.2. DO NOT SCALE DRAWING.3. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND
DESIGN PROFESSIONALS FOR PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED FORCONSTRUCTION.
4. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BEREVIEWED AND APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.
1
2
3
4
5
6
7
8
9
6"MINTYP
6"MINTYP
6"MIN