toshiba_digital inverter system 24pp a4_mcv11.indd
TRANSCRIPT
Made In Japan
Digital Inverter System
SuperDigital Inverter System
Applicable tocertain models.
Toshiba can help you create a comfortable offi ce and home while also caring for the environment.
02
Super Digital InverterSDILatest technology: Newly developed DC twin-rotary compressor, Vector-controlled inverter, Larger propeller fan,
High efficiency DC fan motor, High efficiency heat-transfer and New grille design has excellent efficiency, not only
under rated EER conditions, but also during partial load which is the larger part of actual operating conditions.
Low-noise design: If the outdoor temperature is 30°C or less, operates at under 45 dB
The industry’s first magnetic-action control
The new structure allows a huge reduction in energy loss.
The balanced magnetic-action force to rise and the rotor’s weight minimized the friction laid on the axis
provides excellent operation efficiency.
Friction loss Reducing friction loss
Stator RotorRotor’s weight
Magnetic center
Magnetic action
Current model New model
Outdoor temperature operating range in heating (Wider heating operation)
Heater operation is possible starting from an outdoor temperature of -20°C, while cooling operation is
possible at -15°C outdoor temperature. Creates a comfortable space even during cold winters.
Frost protection
8°C operation for frost protection is possible for the combination with Super Digital Inverter. (4-Way and Slim
Duct series 4)
Sub cool path
Improve reliability for smooth drainage. The outdoor unit of New Super Digital Inverter is equipped with
“Sub cool path” Preventing freeze under a heat exchanger. (Only 3HP to 6HP)
Compatible with pipes up to 75 meters long
Enable the outdoor unit to be installed out of sight increases installation flexibility.
03
Physical data Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E
Standard air flow (H/M/L) m3/h 1050/870/780 1230/960/810 2010/1440/1170 2100/1440/1230
Sound pressure level (H/M/L) dB(A) 32/29/28 35/31/28 43/38/33 44/38/34
Main unit dimensions (H/W/D) mm 256/840/840 256/840/840 319/840/840 319/840/840
Weight kg 20 20 24 24
Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 30/950/950
Panel weight kg 4.2 4.2 4.2 4.2
Physical data Equivalent HP 2HP 3HP 4HP 5HP
Out door unit Standard model (RAV-) SP564ATP-SG SP804ATP-SG SP1104AT-SG SP1404AT-SG
Power supply 1-phase 50Hz 230V (220–240V)
Compressor type DC twin rotary
Running Amphere A 5.57 6.21 9.94 13.82
Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5
Standard / Min. pipe length m 7.5 / 5 7.5 / 5 7.5 / 3 7.5 / 3
Max. pipe total length m 50 50 75 75
Maximum height difference m 30 30 30 30
Outer dimensions (H/W/D) mm 550/780/290 890/900/320 1340/900/320 1340/900/320
Weight kg 44 66 93 93
Standard air flow (Fan unit) m3/h 2400 3000 6060 6180
Sound pressure level, Cooling dB(A) 47 48 49 51
Operating range, Cooling/Heating °C 15~43
Out door unit Standard model (RAV-) SP564ATP-SG SP804ATP-SG SP1104AT-SG SP1404AT-SG
Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E
Cooling*1
Capacity kW 4.8 5.8 9.7 11.2
Range, min-max kW 1.2-5.6 1.9-8.0 2.6-12.0 2.6-14.0
Power consumption kW 1.27 1.37 2.25 2.95
Power supply 1-phase 50Hz 230V (220–240V) / 1-phase 60Hz 220V
Performance dataSDI-Super Digital Inverter
04
SDI Super Digital Inverter 2HP : Outdoor unit drawings
SDI Super Digital Inverter 3HP : Outdoor unit drawings
Discharge guide mounting hole
(4-dia.4.5 embossing)
charge port Earth terminal
Discharge guard
B legs
A legsDrain hole
(Lon
g ho
le p
itch
For
anc
hor
bolt)
(2-dia. 20x88 long hole)
Drain hole(dia. 25)
2-dia. 11-14 U-shape hole
(For dia.8-10 anchor bolts)Refrigerant pipeconnecting port(dia. 12.7 flare at gas side)
Refrigerant pipeconnecting port(dia. 6.4 flare at liquid side)
8-dia. 6 hole
2-dia. 11xL14 long hole
For fixing outdoor unit
(For dia. 8-10 anchor bolts)
dia.
hole
pitc
h
8
35 52
550
21
669.5 147
32 500
780
71
25
22
257483
108
600 90
54108 125
157 79
31 143
145
21
449
483
30
60 30
27
290
306
320
137
93
342
54
Mounting bolt hole(dia. 12x17 long hole)
Details ofA legs
Mounting bolt(dia. 12x17 U-shape hole)
Details of B legs
40 40
12
17.5
365
17.5
Drain hole(dia. 20x88)
7411
812
8 Air inletport
3802006 0
Air inletport
Air outletport
Drain hole(dia. 25)
B legs
46 34 170
75
70383150 600
A legs 3996
320
30
2
1
890
24
4001518018
9555
94
2
1
255
247
155
1880135
90055052
Refrigerant pipeconnecting port(dia. 9.5 flare at liquid side)
Refrigerant pipeconnecting port(dia. 15.9 flare at gas side)
9555
17817817860
32768 518
83 7
765
9555
12 64
1
1
2
Knockout for downward piping
Z views
Refrigerant piping holeIndoor/Outdoor unitconnecting wire inlet hole
Name Note
581
534
148
165
(Unit: mm)
Ø38 Knockout holePower supply inlet hole
05
06
(Unit: mm)
SDI Super Digital Inverter 4&5HP : Outdoor unit drawings
06
6
*Made In Japan
*Applicable to certain models
07
Toshibaoperations
Toshiba Air Conditioning main
production facilities are based in Japan
and Thailand.
Toshiba Carrier Corporation Japan
Toshiba’s Fuji Works is the base for
development of products that employ
the latest in advanced air conditioner
technologies.
The factory is blessed to be situated
such that it looks out on the magnifi cent
natural beauty of Mt. Fuji, Japan’s
tallest and most impressive mountain,
and a symbol by which the nation is
recognized.
Since commencing operations in
1943, Toshiba Fuji Works has been the
birthplace of many excellent products,
including the world’s fi rst split-type duct
free air conditioner, and the world’s
fi rst inverter split-type (duct free) air
conditioner.
The factory is currently home to
development and production of air
conditioners for both residential and
commercial customers: the compressors
that serve as an air conditioner’s heart,
and the advanced inverters, a core
component that adopts Toshiba’s most
advanced technologies.
Toshiba Carrier Thailand Corporation
Located in Pathumthani, approximately
40 km from Bangkok, is the base for
the production of a wide range of
Toshiba residential and light commercial
products incorporating the latest
technologies in energy effi ciency.
Since the factory started its operations
in 1989, the company has earned a
signifi cant number of quality, safety and
environmental certifi cations.
Toshiba air conditioners from Thailand
factory are distributed in more than 50
countries around the world.
Introduction
08
Excellent Energy Effi ciency Ratio
3.59* 3.55* 3.54*3.21*
gy
09
Toshiba Digital Inverter for Economy and EcologyThe Toshiba Digital Inverter air conditioners combine economy and ecology in a
compact body. They feature state-of-the-art technology, fl exible control, and easy
installation to bring natural comfort and convenience to any business environment.
With a wide selection of indoor units to suit your commercial applications,
Toshiba Digital Inverter is certainly the economical and ecological way
to go!
Innovative Inverter Technology
The innovative inverter technology is the heart of Toshiba
Digital Inverter that achieves high power and high effi ciency
simultaneously.
When Toshiba Digital Inverter is switched on, the inverter
control, assisted by PAW (Pulse Amplitude Modulation), rapidly
reaches the desired temperature by increasing compressor
frequency. When the desired temperature has been attained,
the inverter control uses PWM (Pulse With Modulation) to
adjust compressor rotation speed to effi ciently maintain
precise temperature control without consuming excess power.
By adopting this innovative inverter technology, Toshiba
Digital Inverter off ers remarkable energy-saving control,
effi cient economical operation, and excellent comfort.
010
Optimum Comfort
Toshiba Digital Inverter’s inverter technology maintains precise
control of room temperature and creates a comfortable
enviroment.
In conventional units, the compressor switches off once the
set temperature is reached, and switches on again after the
temperature drops. The time it takes for the unit to switch on
and off causes the room temperature to greatly fl uctuate.
With Toshiba Digital Inverter, the inverter control reduces
the compressor power once the desired temperature has
been reached, but continues operating at a reduced state to
maintain a stable room temperature with minimal fl uctuations.
By putting and end to on/off compressor operation, the
inverter technology also allows Toshiba Digital Inverter to
signifi cantly reduce noise levels.
Inverter Air conditioners for
Offi ces, Showrooms, Restaurants,
Other Light Commercial and Household Applications
011
Innovative Outdoor Units
DC twin rotary compressor
Brushless Dccompressor motor
Small and lightweight - With the adoption of refrigerant
R410, Toshiba Digital Inverter outdoor units now boast an ultra
compact and lightweight design for easy and convenient installation.
Easy Installation - In addition to being small and light weight, Toshiba Digital
Inverter’s outdoor units are fi tted with a smaller diameter piping than conventional
models. This means easier installation, shorter installation time and lower installation cost.
With vector IPDU control, noise emitted from the drive unit its greatly reduced by changing the motor current wave to a smooth sinusoidal pattern.
RAV-SM563AT-SGRAV-SM803AT-SG
RAV-SM1103AT-SGRAV-SM1403AT-SG
Technology - Toshiba Digital Inverter’s outdoor units are
equipped with a rotary compressor and IPDU (Intelligent Power Drive
Unit) for high reliability, high effi ciency and low noise.
Various Indoor unit combination - Toshiba Digital Inverter outdoor units are compatible with a selection of indoor
units to match a broad range of applications. Please consult Sales Department for more information.
High-wall TypeDuct Type Ceiling Type Cassette
012
Energy-Savings and Economy
Effi cient energy use — Toshiba Digital Inverters’
powerful yet highly effi cient inverter technology features
energy-saving operation that reduces annual power
consumption by as much as 40% compared to conventional
units.
The variable power levels of the compressor allows Toshiba
Digital Inverter to evenly maintain the room temperature so
that less energy is wasted. Moreover, without the surging
on and shutting off of the compressor in conventional units,
Toshiba Digital inverter can operate as low as 1.5kW*, saving a
bundle of energy.
* In the case of cooling and heating capacity of the Digital Inverter 2HP 4-Way
Cassette Type unit.
Superior COP — In terms of COP (Coeffi cient of
Performance), all Toshiba Digital Inverter models greatly
exceed the standard level.
Toshiba Digital Inverter adopts environmentally-safe, non-
ozone depleting R410A refrigerant, used for the fi rst time in
commercial air conditioners.
R410A refrigerant — In order to meet strict restrictions on the
production of equipment that uses the R22 refrigerant used in
most of commercial air conditioners today, R410A refrigerant
was judged the most appropriate for Toshiba Digital Inverter
units to contribute to environmental preservation.
R410A R407C
Ozone depletion potential (ODP) 0 0
Refrigerant capability
(*comparison with R22)
147% 100%
Pressure loss
(*comparison with R22)
56% 106%
Conventional type
Ecologically-Sustainable
Digital Inverter
013
The Powerful Benefi ts of Digital Inverter
1. Revolutionary ‘Digital Inverter’ technology assures
reduced annual power consumption (up to 40%)
over conventional ‘fi xed speed’ units.
2. The indoor ambient conditions are maintained more
uniformly at desired settings, in spite of variations in
indoor or outdoor load conditions,
3. Year round comfort conditions with the automatic
switch – over of Heating & Cooling mode in all types
of Digital Inverter Indoor units.
4. Longer piping lengths which can cater to various site
conditions.
5. Ecologically sustainable, Non-ozone Depleting
R410A refrigerant used in all units.
6. Fully featured cordless remote available for all types
of indoor units.
7. Group control and Central remote control options
available for all units.
8. Systems are compatible to link up with Toshiba
Super MMS and Mini SMMS systems used for large
installations
9. Compact indoor & outdoor units with smallest foot
print sizes. Easier & effi cient to deliver & install.
10. Low starting current (<1Amp) reduces cost of power
back ups & electrical accessories.
DI Digital Inverter
High-wall Type
Duct Type
Cassette Type
Ceiling Type
014
NEW
NEW
Line up
DI Series
2HP 3HP 4HP 5HP
RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG
4-way Cassette Type
RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E
High-wall Type
RAV-SM566KRT-E RAV-SM806KRT-E – –
Duct Type
RAV-SM566BTP-E RAV-SM806BTP-E RAV-SM1106BTP-E RAV-SM1406BTP-E
Ceiling Type
RAV-SM567CTP-E RAV-SM8077CTP-E RAV-SM11047CTP-E RAV-SM14047CTP-E
NEW
NEW
015
Temperature conditioning
Individual Louvre Control
The angles of each of the four louvres can be set individually
Δ Enables airfl ow to be chosen according to user’s preferences.
Easy installation
The panel is attached using the
bolt that is already installed on the
indoor unit.
4-way Cassette Type
Models
RAV-SM564UT-E
RAV-SM804UT-E
RAV-SM1104UT-E
RAV-SM1404UT-E
Panels
RBC-U31PG(W)-E
RBC-U31PG(W)-E
Wireless remote
controller kit
RBC-AX32U(W)-E
Inverter Allows step-less regulation of the air-conditioner’s power, which reduces energy consumption and improves comfort.
Individual louvre control Enables airfl ows to be chosen according to user’s preferences.
Auto-turn LouvresAir outlet grilles move automatically to fi ll every corner of the room with warm or cool air.
Automatic Air Volume ControlDepending on the diff erence between the room temperature and the set temperature, switches automatically between High, Low and Very Low.
Long- life FilterBuilt-in long-life fi lter makes maintenance easier.
Hot StartWhen using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room.
Automatic Cooling/HeatingAutomatically switches between cooling and heating mode.
DryGradually dehumidifi es the room to create even greater comfort.
Filter SignAutomatic displays on the remote controller say when to perform maintenance for the indoor unit fi lter.
Limit Timer Uses a 168-hour timer with three modes – “On timer”, “OFF timer” and “Repeat OFF timer”.
Cooler Compatible with an Outdoor Temperature of -15°CStable cooler operation is possible when the outdoor temperature is as low as -15°C
Built-in Drain PumpThe built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.)
Comfort Operativity Installation
23 28
2,050 mm
4,500 mm
6,300 mm
Horizontal face750 mm
Mode : coolingLouvre position : horizontalFan speed : Hi
Vertical face
(C)
Three louvre swing patterns
Note: Need to set from wired remote controller
(1) Standard swing (2) Diagonally opposite swing (3) Turn-around
wing
NEW
*Wired remote controller (Optional)
016
1. combination
type 4way cassette 4way cassette (with twin kit)
system-type DI DI DI DI DI DI
indoor-type 4way 4way 4way 4way 4way 4way
capacity hp 2.0 3.0 4.0 5.0 2.0 3.0
indoor RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E RAV-SM564UTP-E RAV-SM804UTP-E
Qty-indoor unit 1 1 1 1 2 2
outdoor RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG
controller (wireless) RBC-AX31U(W)-E
cooling capacity-rated kW 5.1 6.1 9.7 12.5 5.1 6.1
cooling capacity-range kW <1.5 - 5.6> <1.5 - 8.0> <3.0 - 11.2> <3.0 -13.2> < 1.5 - 5.6 > < 1.5 - 8.0 >
cooling power input-rated kW 1.42 1.72 2.74 3.74 1.42 1.72
NEA tick tick √√ √√ √√ √ √√ √
running current (230V) A 6.54 8.14 12.53 16.8 6.54 8.14
fl are connection main pipe (gas) mm 12.7 15.9 15.9 15.9 12.7 15.9
fl are connection main pipe (liquid) mm 6.4 9.5 9.5 9.5 6.4 9.5
pipe length (min) m 5 5 5 5 5 5
pipe length (max) m 30 30 50 50 30 30
chargeless length m 20 20 30 30 20 20
brand kit RBC-TWP30E2 RBC-TWP50E2
2. indoors
model name RAV-SM564UTP-E RAV-SM804UTP-E RAV-SM1104UTP-E RAV-SM1404UTP-E RAV-SM564UTP-E × 2 RAV-SM804UTP-E × 2
indoor 4way 4way 4way 4way 4way 4way
capacity hp 2.0 3.0 4.0 5.0 2.0 3.0
air fl ow-H m3/h 1,050 1,230 2,010 2,100 1,050 1.230
air fl ow-M m3/h 870 960 1,440 1,440 870 960
air fl ow-L m3/h 780 810 1,170 1,230 780 810
sound pressure level (L)/(M)/(H) dB 28 / 29 / 32 28 / 31 / 35 33 / 38 / 43 34 / 38 / 44 28 / 29 / 32 28 / 31 / 35
dimension (H X W X D) mm 256 × 840 × 840 256 × 840 × 840 319 × 840 x 840 319 × 840 × 840 256 × 840 × 840 256 × 840 × 840
weight kg 20 20 24 24 20 20
panel model name RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U321PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E
panel dimension (H × W × D) mm 30 × 950 × 950 30 × 950 × 950 30 × 950 × 950 30 × 950 × 950 30 × 950 × 950 30 × 950 × 950
panel weight kg 4.2 4.2 4.2 4.2 4.2 4.2
fan type turbo fan turbo fan turbo fan turbo fan turbo fan turbo fan
fan motor W 14 20 68 72 14 20
air fi ller Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter
attached remote controller (wireless) RBC-AX32U(W)-E
power input-max(for name Plate) W 40 40 120 120 40 40
3. outdoor
model name RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG
outdoor-type DI DI DI DI DI DI
capacity hp 2.0 3.0 4.0 5.0 4.0 5.0
phase 1 1 1 1 1 1
power supply V 230 230 230 230 230 230
power supply (Hz) Hz 50 50 50 50 50 50
air-fl ow m3/hr 2,400 2,700 4,500 4,500 4,500 4,500
sound pressure level dB 46 48 53 54 53 54
dimension (H × W × D) mm 550 × 780 × 290 550 × 780 × 290 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320
weight kg 38 44 77 77 77 77
compressor type DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary
fan motor output kw 43 43 100 100 100 100
Refrigerant Quantity in Outdoorunit kg 1.0 1.7 2.8 2.8 2.8 2.8
Additional refrigerant charge g/m 20 40 40 40 40 40
power input-max(for NamePlate) kw 2.49 3.41 4.75 4.87 4.75 4.87
installation fuse rating A 16 16 25 25 25 25
power wire mm2 1.5 1.5 2.5 2.5 2.5 2.5
indoor/outdoor connecting wire mm2 1.5 1.5 1.5 1.5 1.5 1.5
017
Features
With its attractive, slim-line design, this unit is best suited for restaurants and other applications
where elegance is required. The fi ltration system further improves the indoor air quality benefi ts
of this high-wall unit.
Key features
With its slim design, this compact and stylish unit blends into any room setting.
Enhanced fi ltration system: Zeolite Plus + Sasa fi lter to deodorise, Bio-Enzyme fi lter
+ Gingko fi lter to purify and a new antioxidant Vitamin C fi lter.
Auto-louvre mode allows optimum air distribution throughout the room.
A wireless controller is included.
a TCC Link remote control is optional.
High-wall Type
Inverter
Allows step-less regulation
of the air-conditioner’s
power, which reduces
energy consumption and
improves comfort.
Auto-turn Louvres
Air outlet grilles move
automatically to fi ll every
corner of the room with
warm or cool air.
Automatic Air Volume
Control
Depending on the
diff erence between the
room temperature and the
set temperature, switches
automatically between
High, Low and Very Low.
Comfort Operativity Installation
Hot Start
When using the heater for
preheating or defrosting,
stops the indoor fan to
prevent cold air from
being blown into the
room.
Automatic Cooling/
Heating
Automatically switches
between cooling and
heating mode.
Dry
Gradually dehumidifi es
the room to create even
greater comfort.
On/Off Timer
The operation start and
stop times can be set with
a digital clock
Cooler Compatible with
an Outdoor Temperature
of - 15°C
Stable cooler operation is
possible when the outdoor
temperature is as low as
-15°C
Models
RAV-SM566KRT-E
RAV-SM806KRT-E
Wireless remote
controller
WH-L11SE
018
1. combination
type Hi Wall Hi Wall (with Twin Kit)
system-type DI DI DI DI
indoor-type high wall high wall high wall high wall
capacity hp 2.0 3.0 2.0 3.0
indoor RAV-SM566KRT-E RAV-SM806KRT-E RAV-SM566KRT-E RAV-SM806KRT-E
Qty-indoor unit 1 1 2 2
outdoor RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-E RAV-SM1403AT-E
cooling capacity-rated kW 5.1 6.1 5.1 6.1
cooling capacity-range kW < 1.5 - 5.6 > < 1.5 - 8.0 > < 1.5 - 5.6 > < 1.5 - 8.0 >
cooling power input-rated kW 1.42 1.74 1.42 1.74
NEA tick tick √√ √√ √√ √
running current (230V) A 6.54 8.14 6.54 8.14
fl are connection main pipe (gas) mm 12.7 15.9 12.7 15.9
fl are connection main pipe (liquid) mm 6.4 9.5 6.4 9.5
pipe length (min) m 5 5 5 5
pipe length (max) m 30 30 30 30
chargeless length m 20 20 20 20
branch kit RBC-TWP30E2 RBC-TWP50E2
2. indoors
model name RAV-SM566KRT-E RAV-SM806KRT-E RAV-SM566KRT-E × 2 RAV-SM806KRT-E × 2
indoor-type high wall high wall high wall high wall
capacity hp 2.0 3.0 2 3
air fl ow-H m3/h 840 1,020 840 1,020
air fl ow-M m3/h 750 750 750 750
air fl ow-L m3/h 660 660 842 660
sound pressure level (L) / (M) / (H) dB 36 / 39 / 42 36 / 41 / 47 36 / 39 / 42 36 / 41 / 47
dimmension (H × W × D) mm 320 × 1050 × 228 320 × 1050 × 228 320 × 1050 × 228 320 × 1050 × 228
weight kg 12 12 12 12
fan type cross fl ow fan cross fl ow fan cross fl ow fan cross fl ow fan
fan motor output W 30 30 30 30
air fi lter Attached Attached Attached Attached
attached remote controller (wireless) WH-L11SE WH-L11SE WH-L11SE WH-L11SE
power input-max(for NamePlate) W 50 70 50 70
3. outdoors
model name RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG
outdoor-type DI DI DI DI DI
capacity hp 2.0 3.0 4 5
phase 1 1 1 1 1
power supply v 230 230 230 230
power supply (Hz) Hz 50 50 50 50
air fl ow m3/h 2,400 2,700 4,500 4,500
sound pressure level dB 46 48 53 54
dimension (H × W × D) mm 550 × 780 × 290 550 × 780 x 290 795 × 900 × 320 795 × 900 × 320
weight kg 38 44 77 77
compressor type DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary
fan motor output W 43 43 100 100
Refrigerant Quantity in Outdoorunit kg 1.0 1.7 2.8 2.8
Additional refrigerant charge g/m 20 40 40 40
power input-max(for NamePlate) kw 2.49 3.41 4.75 4.87
installation fuse rating A 16 16 25 25
power wire mm2 1.5 1.5 2.5 2.5
indoor/outdoor connecting wire mm2 1.5 1.5 1.5 1.5
019
Wide range of applications
The use of ducts allows air outlets to be conveniently installed anywhere on the ceiling,
eliminating the conspicuous presence of the air conditioner in the center of the room. Not only
can this be applied to a wide variety of layouts from narrow spaces to polygonal rooms; it also
greatly improves the aesthetics of a room with its unobtrusive presence.
Polygonal rooms Narrow rooms Rooms with fi xtures and
obstacles
High static pressure
External static pressure can be raised as high as 120pa (max), so that all
areas of the room can be reached for even temperature distribution, no matter how complex the
layout.
High-lift drain pump
The fl exible piping layout is made possible by an optionally available drain-pump kit that raises
the drain piping up to 27 cm from the drain port.
New slimmer chasis with higher static pressure
Reduce from 320mm to 275mm height.
Versatile and Clever
Duct Type
Inverter
Allows step-less regulation
of the air-conditioner’s
power, which reduces
energy consumption and
improves comfort.
Automatic Air Volume Control
Depending on the diff erence
between the room
temperature and
the set temperature,
switches automatically
between High, Low
and Very Low.
Long-life Filter
Built-in long-life fi lter
makes maintenance easier
Hot Start
When using the heater for
preheating or defrosting,
stops the indoor fan to
prevent cold air from
being blown into the
room.
Automatic Cooling/
Heating
Automatically switches
between cooling and
heating mode.
Dry
Gradually dehumidifi es
the room to create even
greater comfort.
Filter Sign
Automatic displays on
the remote controller say
when to perform
maintenance for the
indoor unit fi lter.
Limit Timer
Uses a 168 hour timer with
three modes — “ON timer”,
“OFF timer” and “Repeat
OFF timer”
Cooler Compatible with
an Outdoor Temperature
of - 15°C
Stable cooler operation is
possible when the outdoor
temperature is as low as
-15°C
Built-in Drain Pump
The built-in drain pump
makes draining easier (in
the celling cassette type, it
is built in to the main unit.)
Comfort Operativity Installation
Models
RAV-SM566BTP-E
RAV-SM806BTP-E
RAV-SM1106BTP-E
RAV-SM1406BTP-E
Wired remote
controller
RBC-AMT32E
*Wireless remote controller (Optional)
020
1. combination
type Standard ducted Standard ducted (with Twin Kit)
system-type DI DI DI DI DI DI
indoor-type duct duct duct duct duct duct
capacity rank hp 2.0 3.0 4.0 5.0 2.0 3.0
indoor RAV-SM566BTP-E RAV-SM806BTP-E RAV-SM1106BTP-E RAV-SM1406BTP-E RAV-SM566BTP-E RAV-SM806BTP-E
Qty-indoor unit 1 1 1 1 2 2
outdoor RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG
controller (wired) RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E
cooling capacity-rated kW 5.1 6.1 9.7 12.5 5.1 6.1
cooling capacity-range kW < 1.5 - 5.6 > < 1.5 - 8.0 > < 3.0 - 11.2 > < 3.0 - 13.2 > < 1.5 - 5.6 > < 1.5 - 8.0 >
cooling power input-rated kW 1.42 1.72 2.74 3.74 1.42 1.72
NEA tick tick √√ √√ √√ √ √√ √
running current (230V) A 6.54 8.14 12.53 16.8 6.54 8.14
fl are connection main pipe (gas) mm 12.7 15.9 15.9 15.9 12.7 15.9
fl are connection main pipe (liquid) mm 6.4 9.5 9.5 9.5 6.4 9.5
pipe length (min) m 5 5 5 5 5 5
pipe length (max) m 30 30 50 50 30 30
chargeless length m 20 20 30 30 20 20
branch kit RBC-TWP30E2 RBC-TWP50E2
2. indoors
model name RAV-SM566BTP-E RAV-SM806BTP-E RAV-SM1106BTP-E RAV-SM1406BTP-E RAV-SM566BTP-E × 2 RAV-SM806BTP-E × 2
indoor-type duct duct duct duct duct duct
capacity hp 2.0 3.0 4.0 5.0 2.0 3.0
air fl ow-H m3/h 800 1,200 2,100 2,100 N.A N.A
air fl ow-M m3/h 630 930 1,650 1,650 N.A N.A
air fl ow-L m3/h 480 720 1,260 1,260 N.A N.A
sound pressure level (L)/(M)/(H) dB 25 / 29 / 33 26 / 30 / 34 33 / 36 / 40 33 / 36 / 40 25 / 29 / 33 26 / 30 / 34
dimmension (H × W × D) mm 275 × 700 × 750 275 × 1000 x 750 275 × 1400 × 750 275 × 1400 × 750 275 × 700 × 750 275 × 1000 × 750
weight kg 23 30 40 40 40 40
external static pressure (std) Pa 40 40 40 40 40 40
external static pressure (upper) Pa 120 120 120 120 120 120
external static pressure (lower) Pa 30 30 30 30 30 30
fan type centrifugal fan centrifugal fan centrifugal fan centrifugal fan centrifugal fan centrifugal fan
fan motor output 120 120 120 120 120 120
air fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter
attached remote controller (wired) RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E
power input-max(for NamePlate) w 150 150 250 250 150 150
3. outdoors
model name RAV-SM563AT-SG RAV-SM803AT-SG RASV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG
outdoor-type DI DI DI DI DI DI
capacity rank hp 2.0 3.0 4.0 4.0 5.0 5.0
phase 1 1 1 1 1 1
power supply v 230 230 230 230 230 230
power supply (Hz) Hz 50 50 50 50 50 50
air fl ow m3/h 2,400 2,700 4,500 4,500 4,500 4,500
sound pressure level (cooling) dB 46 48 53 54 53 54
dimension (H × W × D) mm 550 × 780 × 290 550 x 780 × 290 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320
weight kg 38 44 77 77 77 77
compressor type DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary
fan motor output kw 43 43 100 100 100 100
Refrigerant Quantity in Outdoor unit kg 1.0 1.7 2.8 2.8 2.8 2.8
Additional refrigerant charge g/m 20 40 40 40 40 40
power input-max(for NamePlate) kw 2.49 3.41 4.75 4.87 4.75 4.87
installation fuse rating A 16 16 25 25 25 25
power wire mm2 1.5 1.5 2.5 2.5 2.5 2.5
indoor/outdoor connecting wire mm2 1.5 1.5 1.5 1.5 1.5 1.5
021
Comfortable ambience
Quietest in industryA new design has been adopted that greatly reduces the noise level to half that of conventional
units. Operation is always whisper-quiet.
Flap controlThe airfl ow angle is automatically set to the most suitable setting according to your cooling or
heating needs, and an automatic swing mode enables airfl ow to reach all areas of the room to
create a comfortable ambience.
Installation effi ciency
Suspending the unit from the ceiling saves the trouble of complex installation procedures. It
can be suspended simply by adjusting two screws on the intake grill. Compared to conventional
units which involve a dozen screws, installation is further simplifi ed.
Quiet and Comfortable
Ceiling Type
Models
RAV-SM567CTP-E
RAV-SM807CTP-E
RAV-SM1107CTP-E
RAV-SM1407CTP-E
Wired remote
controller
RBC-AMT32E
*Wireless remote controller (Optional)
Inverter
Allows step-less regulation
of the air-conditioner’s
power, which reduces
energy consumption and
improves comfort.
Automatic Air Volume
Control
Depending on the
diff erence between the
room temperature and
the set temperature,
switches automatically
between High, Low and
Very Low.
Long-life Filter
Built-in long-life fi lter
makes maintenance easier
Comfort Operativity Installation
Hot Start
When using the heater for
preheating or defrosting,
stops the indoor fan to
prevent cold air from
being blown into the
room.
Auto-turn Louvers
Air outlet grilles move
automatically to fi ll every
corner of the room with
warm or cool air.
Dry
Gradually dehumidifi es
the room to create even
greater comfort.
Filter Sign
Automatic displays on
the remote controller say
when to perform
maintenance for the
indoor unit fi lter.
Limit Timer
Uses a 168 hour timer with
three modes — “ON timer”,
“OFF timer” and “Repeat
OFF timer”
Cooler Compatible with
an Outdoor Temperature
of - 15°C
Stable cooler operation is
possible when the outdoor
temperature is as
low as -15°C
Built-in Drain Pump
The built-in drain pump
makes draining easier (in
the celling cassette type, it
is built in to the main unit.)
In cooling
mode, the fl ap
automatically
swings between
the top three
positions
In heating
mode, the fl ap
automatically
swings between
all fi ve positions.
123
45
30˚30˚
123
45
60˚60˚
022
1. combination
type Under ceiling Under ceiling (with Twin Kit)
system-type DI DI DI DI DI DI
indoor-type ceiling ceiling ceiling ceiling celling celling
capacity hp 2.0 2.0 4.0 5.0 2.0 3.0
indoor RAV-SM567CTP-E RAV-SM807CTP-E RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM567CTP-E RAV-SM807CTP-E
Qty-indoor unit 1 1 1 1 2 2
outdoor RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG
controller (wired) RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E
cooling capacity-rated kW 5.1 6.1 9.7 12.5 5.1 6.1
cooling capacity-range < 1.5 - 5.6 > < 1.5 - 8.0 > < 3.0 - 11.2 > < 3.0 - 13.2 > < 1.5 - 5.6 > < 1.5 -8.0 >
cooling power input-rated kW 1.42 1.72 2.74 3.74 1.42 1.72
NEA tick tick √√ √√ √√ √ √√ √
running current (230V) A 6.54 8.14 12.53 16.8 6.54 8.14
fl are connection mian pipe (gas) mm 12.7 15.9 15.9 15.9 12.7 15.9
fl are connection main pipe (liquid) mm 6.4 9.5 9.5 9.5 6.4 9.5
pipe length (min) m 5 5 5 5 5 5
pipe length (max) m 30 30 50 50 30 30
chargeless length m 20 20 30 30 20 20
branch kit RBC-TWP30E2 RBC-TWP50E2
2. indoors
model name RAV-SM567CTP-E RAV-SM807CTP-E RAV-SM1107CTP-E RAV-SM1407CTP-E RAV-SM567CTP-E × 2 RAV-SM807CTP-E × 2
indoor-type celling celling celling celling celling celling
capacity rank hp 2.0 3.0 4.0 5.0 2.0 3.0
air fl ow-H m3/h 900 1,410 1,860 2,040 900 1,410
air fl ow-M m3/h 720 1,002 1,350 1,530 720 1,002
air fl ow-L m3/h 540 750 1,020 1,200 540 750
air-fl ow-H m3/min 15.0 23.5 31.0 34.0 15.0 23.5
air-fl ow-M m3/min 12.0 16.7 22.5 25.5 12.0 16.7
air-fl ow-L m3/min 9.0 12.5 17.0 20.0 9.0 12.5
sound pressure level (L)/(M)/(H) dB 28/35/37 29/36/41 32/38/44 35/41/46 28/35/37 29/36/41
dimmension (H × W × D) mm 235 × 950 × 690 235 ×1,270 × 690 235 × 1,586 × 690 235 × 1,586 × 690 235 × 950 × 690 235 × 1,270 × 690
weight kg 23 29 35 35 23 29
fan type centrifugal fan centrifugal fan centrifugal fan centrifugal fan centrifugal fan centrifugal fan
fan motor output W 94 94 139 139 94 94
air fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter Long life fi lter
attached remote controller (wired) RBC-AMT32-E RBC-AMT32-E RBC-AMT32-E RBC-AMT32-E BBC-AMT32-E BBC-AMT32-E
power input-max(for NamePlate) W 94 94 150 150 94 94
3. outdoors
model name RAV-SM563AT-SG RAV-SM803AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG RAV-SM1103AT-SG RAV-SM1403AT-SG
outdoor-type DI DI DI DI DI DI
capacity rank 2.0 3.0 4.0 5.0 4.0 5.0
phase 1 1 1 1 1 1
power supply v 230 230 230 230 230 230
power supply (Hz) 50 50 50 50 50 50
air fl ow m3/h 2,400 2,700 4,500 4,500 4,500 4,500
sound pressure level (cooling) dB 46 48 53 54 53 54
dimension (H × W × D) mm 550 × 780 × 290 550 × 780 × 290 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320 795 × 900 × 320
weight kg 38 44 77 77 77 77
compressor type DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Ratory DC Twin Ratory
fan motor output kw 43 43 100 100 100 100
Refrigerant Quantity in Outdoor unit kg 1.0 1.7 2.8 2.8 2.8 2.8
Additional refrigerant charge g/m 20 40 40 40 40 40
power wire mm2 1.5 1.5 2.5 2.5 2.5 2.5
indoor/outdoor connecting wire 1.5 1.5 1.5 1.5 1.5 1.5
023
Z view
155
28.5
6157
64
187
32
Bottom face of ceiling
Knockout for fresh
air intake dia.150
300 or less
Sta
nd
-up
66
1 o
r le
ss*
Stan
d-u
p 8
50 o
r le
ss
Bottom face of ceiling
Bottom face
of ceiling
Drain-up standing-up size
860 to 910 Ceiling open dimension
860
to 9
10 C
eilin
g o
pen
dim
ensi
on
Ceiling panel (Sold separately)
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Hanging bolt M10 orW3/8 local arrange
Drain discharge port
For branch duct knockout square hole 150 (diam.)
For branch duct knockout square hole
150 (diam.) (Also located on the back)
*( ): 110–140 type
12
9
132 2
56
30
101
16.5
351
480
256.5
196.5
38435 105
223.5
163.5
7774
105
(18
3)
*1
20
*(1
37
)
*(3
19
)
1000 or more 1000 or more
15
or
mo
re
15
or
mo
re
10
00
or
mo
re
Space required for installation
241.5
263
397.5
12
9
18
9
337.5
30
105
72 106.5
17
2
112
44
157
Wiring connection port
Z 45
95
0 P
an
el e
xte
rna
l dim
en
sio
n
78
0 H
an
gin
g b
olt
pit
ch
416.5
408
690 20 Hanging bolt pitch
950 Panel external dimension
26
9
32
3
Electric parts box
HIGHWALL
RAV-SM566KRT-E
Ceiling
RAV-SM806KRT-E
56 type
80 type
120 to 140 type
ACapacity class
855
1125
1540
910
1180
1595
B
(mm)
B
(Ha
ng
ing
p
osi
tio
n)
A (Hanging position)
Refrigerant pipe (Gas side)
Wireless sensor mounting section
Piping hole on the wall (dia.100 hole)
Drain pipe connecting port
Air intake port dia.92 *(Duct sold separately)
Drain left piping extake port *
Remote controller cable intake port *
Remote controller cable intake port *
Piping extake port *
Drain port VP20
(Inner dia.62, hose supplied)
Power supply intake port *Refrigerant pipe (Liquid side)
17
03
20
84
128
Left drain size
Remote controller piping intake port *
Power supply cable intake port *
Upper piping extake port *
110 50
130
216
146
75 97
76
53
70
135
17
1
90
32
92
14
5
347
3284
262
Z view
Space required for installation and servicing
(Front side to bepositioned horizontally)
250 or more
250 or more
500
or
mo
re
Ceiling surface
Unit
Wit
hin
50
Hanging bolt
68
0
167105
114
141
210
20
0 (
Liq
uid
pip
e)
21
6 (
Ga
s p
ipe
) * : Knockout hole
Z
Indoor units4-way cassette
Unit: mm
024
RAV-SM806BTP-E
DUCT
RAV-SM566BTP-E
Outdoor units Unit: mm
RAV-SM1106BTP-E
RAV-SM1406BTP-E
025
RAV-SM563AT-SG~RAV-SM803AT-SG
RAV-SM1103AT-SG~RAV-SM1403AT-SG
Refrigerant pipe connecting port (Gas side)
Refrigerant pipe connecting port (Liquid side)
Refrigerant pipe connecting port (Gas side)
Hanger (both sides)
Refrigerant pipe connecting port (Liquid side)
8-dia.6 hole (for fixing outdoor unit)
Charging port
Mounting bolt hole
(2-dia.12x17 U-shape cut-out)
Mounting bolt hole
(2-dia.12x17 long hole)
Drain hole dia.25
(An
cho
r b
olt
lo
ng
ho
le
pit
ch)
(An
chor
bol
t lo
ng
hol
e p
itch
)
(dia
.6 h
ole
p
itch
)
B leg part
A leg part
B leg part
A leg part
Air outlet
Air inlet Drain hole (dia.25)
DI110~140 type
Drain hole (dia.20x88)
Knock out
(for drain)
Knockout(for drain)
Knockout for lower piping
Air
in
let
2-dia.11x14 long hole
(for dia.8–10 anchor bolt)
2-dia.11x14 U-shape cut-out
(for dia.8–10 anchor bolt)2-dia.20x88 drain long hole
2-dia.6 hole
Detailed A leg part
Detailed A leg part
Detailed B leg part
Detailed B leg part
Fan guard
2-dia.6 hole
60
30
20
30
54
600
108 125
9038
54
R5.5
R15
14769.5 21
55
0
48
3
32
0
30
6
29
0
63
5
44
9
36
51
7.5
17
.5
13
7
93
528 500
483
108
257
32
25
22
71
780
38
54
R5.5
R15
11
145
342
157 79
21
14331
54
36 (43)
95
52
600
29 90 20191
150
602621
40
21
70
(47
)
39
43
40
900
314550
270
43
95
39
47
17
.5
40
40
28
17
.5
320
50
25
Z view
Z300
56
51
01
307
60
96
27
B
C
6067
15
4 D E
254
518
53
42
50
86 7
58
7
27 58
46
161
400
B
B
F G
C
C60
25
90
89
79
5
16
5
60
8026
4
Air inlet
Air outlet
Air
inle
t
Space required for service
150 or more
150 or more500 or more
300 or more
DI
B
C
Power supply wiring hole dia.38 knockout hole
56–140 typeName
Piping drawing port
Outdoor units Unit: mm
026
Remote ControllersToshiba Digital Inverters operated with an easy-to-use remote controller.
Indoor unit 4-Way Cassette Ducted Under Ceiling High-WallRAV-SM**4UTP-E RAV-SM**6BTP-E RAV-SM**7CTP-E RAV-SM**6KRT-E
Remoto controller RBC-AX32U(W)-EWireless remote controller kit *RBC-AX32CE2Wireless remote controller kit *TCB-AX32E2Wireless remote controller kit * *RBC-AMS51E-ENLite-Vision plus remote controller * * * *RBC-AMT32EWired remote controller * * * *RBC-EXW21EWeekly timer * * * *TCB-SC642TLE2Central remote controller * * * *
Note: To link to CRC Control, a net adapter interface card is required - model TCB-PCNT30TLE2
027
Cost Saving
Comfort
An effi cient use of time
TCC-SDI 2016/05