tp-200 · r.l. 33.650 r.l. 31.700 internal ground floor of building g (shown dashed) c01 gl01 gl01...
TRANSCRIPT
-
A
B
C
E
J
L
M
N
O
G
50
48 54
133
73
7167
65
63
51
-
59
D
F
H
K
GROUND (FOYER/C/D)R.L.6.550
BASEMENT 3R.L.2.650
NO
RT
H T
ITLE
BO
UN
DA
RY
(O
N A
NG
LE
)
NO
RT
H T
ITLE
BO
UN
DA
RY
(B
EY
ON
D)
2.2m HIGH BOUNDARY FENCE
(SHOWN DASHED)
EXTENT OF BUILDING (SHOWN DASHED)
4590
SETBACK
2455
ROOF (E/F/J)R.L.30.900
LEVEL 2 (E/F/J)R.L.27.300
LEVEL 1 (E/F/J)R.L.24.000
GROUND (E/F/J)R.L.20.700
BASEMENT 1/LEVEL -1 (E/F/J)R.L.17.400
LEVEL 1 (C/D)R.L.10.350
LEVEL 2 (C/D)R.L.13.650
LEVEL 3 (C/D)R.L.16.950
ROOF (C/D)R.L.20.550
A L
E X
A N
D R
A
A V
E N
U E
T I
T L
E
T I
T L
E
3600
3300
3300
3800
3900
3600
3300
3300
3300
C01
C01
SCR01
CR01
CR01
C01
C01
MT01
C01
21390
SCR01
GL01 GL01
GL01
28545
C01
TERRACING TO LANDSCAPE
SHOWN DASHED
APT E.L-1
MASTER BEDC02
EXISTING 2.8m HIGH TIMBER
FENCE (SHOWN DASHED)
PROPOSED 2.2m HIGH BOUNDARY
FENCE (SHOWN DASHED)
R.L. 27.300
EXISTING NATURAL
GROUND LEVEL AT TITLE
BOUNDARY
PROPOSED GROUND LEVEL
BEYOND
5995
2280
8315
2275
4370
9330
800
R.L. 21.350
R.L. 20.550
BASEMENT 2 / TERRACE R.L.13.800
SO
UT
H T
ITLE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
2.2m HIGH BOUNDARY
FENCE (SHOWN DASHED)
10m HEIGHT LIMIT (SHOWN DASHED)
EXTENT OF BUILDING SHOWN DASHED
R.L. 32.850
R.L. 30.900
SETBACK
4655 12145 9295
R.L. 33.800
R.L. 30.900
BASEMENT 1/LEVEL -1 (E/F/J) R.L.17.400
GROUND FLOOR (G/H) R.L.22.650
LEVEL 1 (G/H) R.L.25.950
LEVEL 2 (G/H) R.L.29.250
ROOF (G/H) R.L.32.850
T I
T L
E
T I T
L E
C01
CR01
C01
SCR01
SCR01
CR01
CR01
SCR01C01
CR01
C01
CR01
CR01
SCR01
SCR01
C01
CR01
C01
CR01
CR01
SCR01
SCR01SCR01 SCR01
R.L. 33.650
R.L. 31.700
INTERNAL GROUND FLOOR OF BUILDING G
(SHOWN DASHED)
C01 GL01
GL01
C02 GL01 GL01 GL01 GL01 C02
GL01
C02 GL01 C02
239209120
C01 C01
C01
C01
ROOF (N) R.L.33.000
LEVEL 2 (N) R.L.29.400
LEVEL 1 (N) R.L.26.100
GROUND (N) R.L.22.800
EXISTING PAILING FENCE
(SHOWN DASHED)
R.L. 33.000
PROPOSED GROUND LEVEL BEYONDEXISTING NATURAL GROUND LEVEL AT
TITLE BOUNDARY
SCR02
ROOF PLANT
SCR02
ROOF PLANT
74858
915
3600
5315
8615
8360
8260
8145
3600
3300
3300
800
800
800
LIFT OVERRUN
LIFT OVERRUN
LIFT OVERRUN
1500h PLANT SCREEN
SCR02
1500h PLANT SCREEN
SCR02
GROUND (FOYER/C/D) R.L.6.550
BASEMENT 3R.L.2.650BASEMENT 3 R.L.2.650
LEVEL 1 (C/D) R.L.10.350
LEVEL 2 (C/D) R.L.13.650
LEVEL 3 (C/D) R.L.16.950
ROOF (C/D) R.L.20.550
LEVEL 1 (B)R.L.9.600
GROUND (B)R.L.6.300
LEVEL 2 (B)R.L.12.900
ROOF (B)R.L.16.500
ROOF (A)R.L.15.550
LEVEL 2 (A)R.L.11.950
LEVEL 1 (A)R.L.8.650
GROUND (A)R.L.5.350
3900
3800
3300
3300
3600
3650
3300
3300
3600
2700
3300
3300
3600
WE
ST
TIT
LE
BO
UN
DA
RY
EA
ST
TIT
LE
BO
UN
DA
RY
SETBACK
490040005650
SETBACK
4570
A L E X A N D R A A V E N U E
10m HEIGHT LIMIT AT NORTH FACADE OF
BUILDING LINE (SHOWN DASHED)
10m HEIGHT LIMIT AT NORTH FACADE
OF CORE (SHOWN DASHED)
BASEMENT (SHOWN DASHED)
BUILDINGS IN DISTANCE WITHIN 10m
HEIGHT LIMIT - REFER TO SECTIONS
10m HEIGHT LIMIT IN DISTANCE (SHOWN AT
BUILDING C/D LEVEL 3 NORTH FACADE LINE)
GL01
CR01
C01
CR01
GL01
CR01
C01
C01
C01
C01
GL01
MT01
C01
C01
C01
C01
GL01
MT01
RE01RE01
CR01
R.L. 32.850
R.L. 30.900
R.L. 28.300
R.L. 27.300
8340 11130 11130
MT01C01
METAL DRIVEWAY ENTRY DOOR
GL01GL01
GL01
GL01
GL01
MT01
GL01
GL01
MT01
GL01
GL01
C01C01C01
C01
CR01
SERVICES
C01
BUILDING ENTRY LOBBY
SETBACK
8000
3125
4400
10955
1000
650
1700
650mm HIGH PLANTER
WITH 1M BALUSTRADE
CR01
CR01
CR01 MT01
CR01
C01
CR01
13
3 A
LE
XA
ND
RA
AV
EN
UE
(IN
FR
ON
T)
73
KE
NS
ING
TO
N R
D (
IN F
RO
NT
)
MIN 1.7m HIGH FENCE
5995
9985
9360
9995
9725
9990
7940
8005
800
800
R.L. 20.550
R.L. 21.350
LIFT OVERRUN
R.L. 17.300
R.L. 16.500
LIFT OVERRUN
10M HEIGHT LIMIT OF
BUILDING C LEVEL 2
BASEMENT 3R.L.2.650
ROOF (A)R.L.15.550
LEVEL 2 (A)R.L.11.950
LEVEL 1 (A)R.L.8.650
GROUND (A)R.L.5.350
5410 2675
A L
E X
A N
D R
A
A V
E N
U E
2700
3300
3300
3600
NO
RT
H T
ITLE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
133 ALEXANDRA AVENUE (SHOWN DASHED)
PROPOSED 2.2m HIGH BOUNDARY FENCE
(SHOWN DASHED)
10m HEIGHT LIMIT AT BUILDING LINE
(SHOWN DASHED)
BASEMENT (SHOWN DASHED)
10m HEIGHT LIMIT IN DISTANCE (SHOWN AT
BUILDING B WESTERN-MOST FACADE LINE)
BUILDING B WITHIN 10m HEIGHT LIMIT
SCR01SCR01
C01
CR01
CR01
CR01
C01
C01
SCR01SCR01SCR01
C01
C01 C01C01
SCR01
GL01 GL01 GL01C01GL01
SCR01
28490
R.L. 15.550
EXISTING BOUNDARY FENCE
(SHOWN DASHED)PROPOSED GROUND LEVEL BEYOND
EXISTING NATURAL GROUND LEVEL AT
TITLE BOUNDARY
9990
7055
SCR01
MATERIAL SCHEDULE
NATURAL CEMENT RENDER
SANDBLASTED CONCRETE
TEXTURED, STRIATED CONCRETE
RAMMED EARTH
CLEAR GLAZING
25% TRANSPARENT GLASS
BRONZE-COLOURED METAL
SCREEN SCHEDULE
SCR01BRONZE-COLOURED METAL SCREEN, 25%
OPEN TO 1.7m ABOVE FFL - REFER TO
TP-406 FOR SCREEN DETAIL
C01
C02
RE01
CR01
GL01
MT01
GL02
SCR02ROOF PLANT SCREEN BRONZE COLOURED PERFORATED MESH
Builders / Contractors shall verify all dimensions before any work
commences. Dimensions shown are nominal. Figured dimensions
shall take precedence over scaled dimensions. Any discrepancies
are to be made known to the Architects / Designers studio prior to
any works commencing on site. All shop drawings shall be
submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205
© Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4
31 Flinders Lane
Melbourne VIC
3000 Australia
PO Box 18069
Collins Street East
Melbourne VIC
8003 Australia
+61 3 9665 2300
carr.net.au
Based on Drawings Received:
As indicated
1
Alexandra Avenue - BUILDING
ELEVATIONS SHEET 01
18094
TP-200
16.11.18
TK
135-141 Alexandra Avenue, South Yarra
DB
03
SCALE 1 : 250SK - 113
EAST ELEVATION3
SCALE 1 : 250SK - 113
NORTH ELEVATION1SCALE 1 : 250SK - 113
WEST ELEVATION2
02
01
XX BUILDING HEIGHT ABOVE NGL
(NGL TAKEN AT BUILDING LINE CORNERS)
1 18/01/2018 DB RFI RESPONSE
-
BASEMENT 2 / TERRACE R.L.13.800
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
ROOF (K) R.L.28.300
LEVEL 2 (K) R.L.24.700
LEVEL 1 (K) R.L.21.400
GROUND (K) R.L.18.100
4300
3300
3300
3600
R O
C K
L E
Y
R O
A D
1132515895
PR
OP
OS
ED
SU
BD
IVIS
ION
PROPOSED 2.2m HIGH BOUNDARY FENCE
(SHOWN DASHED)
10m HEIGHT LIMIT AT BUILDING LINE
(SHOWN DASHED)
POOL TERRACE (SHOWN DASHED)
GL01
GL01
GL01
GL01
GL01
GL01
MT01
MT01
CR01
CR01
CR01
C01
C01
C02
GL01
GL01
GL01
GL01
GL01
GL01
24055 15265
R.L. 29.100
SIGHT LINE
1500
R.L. 28.300
PLANTER
PLANTER
C01
C01
PROPOSED GROUND LEVEL BEYOND
EXISTING NATURAL GROUND LEVEL AT TITLE BOUNDARY
SCR02
9990
9170
9300
LIFT OVERRUN
800
ROOF PLANT
1500h PLANT SCREEN
SCR02
BASEMENT 2 / TERRACER.L.13.800
GROUND (M) R.L.21.800
LEVEL 1 (M) R.L.25.100
LEVEL 2 (M) R.L.28.400
ROOF (M) R.L.32.000
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
R O
C K
L E
Y
R O
A D
300019390
ROOF (K)R.L.28.300
LEVEL 2 (K)R.L.24.700
LEVEL 1 (K)R.L.21.400
GROUND (K)R.L.18.100
4300
3300
3300
3600
PR
OP
OS
ED
SU
BD
IVIS
ION
1500 1500
10m HEIGHT LIMIT AT BUILDING LINE
(SHOWN DASHED)
BASEMENT (SHOWN DASHED)
CR01
CR01
CR01
C02
C01
C01
GL01
SCR01 C01
C01
C01
C01 SCR01
SCR01
R.L. 29.100
2078015370
1500
SIGHT LINE
EXISTING BOUNDARY FENCE
(SHOWN DASHED)
PROPOSED 2.2M BOUNDARY
FENCE (SHOWN AS SOLID LINE)
SCR01 SCR01
R.L. 28.300
EXISTING NATURAL GROUND
LEVEL AT TITLE BOUNDARY
SCR02
EXTENT OF EXISTING
BOUNDARY FENCE (LEFT)
6560
9120
8425
800
LIFT OVERRUN
ROOF PLANT 1500h
PLANT SCREEN
SCR02
A
B
C
E
J
L
M
N
O
G
50
48 54
133
73
7167
65
63
51
-
59
D
F
H
K
BASEMENT 2 / TERRACE R.L.13.800 BASEMENT 2 / TERRACER.L.13.800
GROUND (M)R.L.21.800
LEVEL 1 (M)R.L.25.100
LEVEL 2 (M)R.L.28.400
ROOF (M)R.L.32.000
ROOF (E/F/J) R.L.30.900
LEVEL 2 (E/F/J) R.L.27.300
LEVEL 1 (E/F/J) R.L.24.000
GROUND (E/F/J) R.L.20.700
BASEMENT 1/LEVEL -1 (E/F/J) R.L.17.400 BASEMENT 1/LEVEL -1 (E/F/J)R.L.17.400
3600
3300
3300
3300
3600
SO
UT
H T
ITLE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
3600
4400
3300
3300
3600
12655 4125
51-5
9 K
EN
SIN
GT
ON
RO
AD
EXISTING 3M HIGH BOUNDARY FENCE
(SHOWN DASHED)
T I T
L E
10m HEIGHT LIMIT AT BUILDING LINE
(SHOWN DASHED)
BASEMENT (SHOWN DASHED)
C01
C01SCR01SCR01
SCR01SCR01
CR01
CR01
CR01
CR01
CR01
GL01 GL01
GL01
GL01
GL01
GL01
GL01
C01
RE01
CR01
GL01
21070
GL01CR01
LIFT LOBBY BUILDING J
900
900mm HIGH PLANTER WITH 1M BALUSTRADE
R.L. 30.900
R.L. 31.800
3000
PLANTER
PLANTER
PLANTER
PLANTER
PROPOSED GROUND LEVEL BEYOND
EXISTING NATURAL GROUND LEVEL AT TITLE BOUNDARY
R.L. 21.800
SCR02
SCR02
9380 9510
9500
9015
LIFT OVERRUN
R.L. 31.700
800
ROOF PLANT 1500h
PLANT SCREEN
SCR02
ROOF PLANT 1500h
PLANT SCREEN
SCR02
BASEMENT 3R.L.2.650BASEMENT 3 R.L.2.650
LEVEL 1 (B)R.L.9.600
GROUND (B)R.L.6.300
LEVEL 2 (B)R.L.12.900
ROOF (B)R.L.16.500
ROOF (A) R.L.15.550
LEVEL 2 (A) R.L.11.950
LEVEL 1 (A) R.L.8.650
GROUND (A) R.L.5.350
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
13
3 A
LE
XA
ND
RA
AV
EN
UE
4900 4000
3600
3300
3300
2700
3650
3300
3300
3600
PROPOSED 2.2m HIGH BOUNDARY FENCE
(SHOWN DASHED)
10m HEIGHT LIMIT AT BUILDING LINE
(SHOWN DASHED)
BUILDING & BASEMENT (SHOWN DASHED)
CR01
CR01
C01
C01
GL01
GL01
CR01
C01
SCR01
C01
GL01 C01
C01
11130 10920
R.L. 15.550
R.L. 16.500
1700
MIN 1.7m HIGH FENCE
P.O.S
P.O.S
EXISTING NATURAL GROUND
LEVEL AT TITLE BOUNDARY
PROPOSED GROUND LEVEL
BEYOND
7055
4060 4065 2370
800
R.L. 17.300LIFT OVERRUN
MATERIAL SCHEDULE
NATURAL CEMENT RENDER
SANDBLASTED CONCRETE
TEXTURED, STRIATED CONCRETE
RAMMED EARTH
CLEAR GLAZING
25% TRANSPARENT GLASS
BRONZE-COLOURED METAL
SCREEN SCHEDULE
SCR01BRONZE-COLOURED METAL SCREEN, 25%
OPEN TO 1.7m ABOVE FFL - REFER TO
TP-406 FOR SCREEN DETAIL
C01
C02
RE01
CR01
GL01
MT01
GL02
SCR02ROOF PLANT SCREEN BRONZE COLOURED PERFORATED MESH
Builders / Contractors shall verify all dimensions before any work
commences. Dimensions shown are nominal. Figured dimensions
shall take precedence over scaled dimensions. Any discrepancies
are to be made known to the Architects / Designers studio prior to
any works commencing on site. All shop drawings shall be
submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205
© Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4
31 Flinders Lane
Melbourne VIC
3000 Australia
PO Box 18069
Collins Street East
Melbourne VIC
8003 Australia
+61 3 9665 2300
carr.net.au
Based on Drawings Received:
As indicated
1
Alexandra Avenue - BUILDING
ELEVATIONS SHEET 02
18094
TP-201
16.11.18
TK
135-141 Alexandra Avenue, South Yarra
DB
SCALE 1 : 250SK - 113
NORTH ELEVATION2
SCALE 1 : 250SK - 113
SOUTH ELEVATION3SCALE 1 : 250SK - 113
WEST ELEVATION4
SCALE 1 : 250SK - 113
SOUTH ELEVATION1
010203
04
REFER TO DRAWING TP-203 FOR 50 ROCKLEY RD COMPARISON STUDY WITH APPROVED SCHEME
REFER TO DRAWING TP-203 FOR 50 ROCKLEY RD COMPARISON STUDY WITH APPROVED SCHEME
XX BUILDING HEIGHT ABOVE NGL
(NGL TAKEN AT BUILDING LINE CORNERS)
1 18/01/2018 DB RFI RESPONSE
-
BASEMENT 2 / TERRACE R.L.13.800
GROUND (M) R.L.21.800
LEVEL 1 (M) R.L.25.100
LEVEL 2 (M) R.L.28.400
ROOF (M) R.L.32.000
BASEMENT 1/LEVEL -1 (E/F/J) R.L.17.400
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
3600
3300
3300
4400
3600
5030 4450
EXISTING 3M HIGH BOUNDARY FENCE
(SHOWN DASHED)
48
RO
CK
LE
Y R
OA
D
51-5
9 K
EN
SIN
GT
ON
RO
AD
51-59 KENSINGTON RD
10m HEIGHT LIMIT AT BUILDING LINE
(SHOWN DASHED)
BASEMENT (SHOWN DASHED)
C01
C01GL01
CR01
CR01
SCR01
GL01
SCR01
C01GL01 GL01
R.L. 32.800
15490
CR01
R.L. 32.000
GL01
GL01
PROPOSED GROUND LEVEL BEYOND
EXISTING NATURAL GROUND LEVEL AT TITLE BOUNDARY
SCR02
9015
9015
800
LIFT OVERRUNROOF PLANT 1500h
PLANT SCREEN
SCR02
SCR01
ROOF (O)R.L.31.538
LEVEL 1 (O)R.L.27.938
GROUND (O)R.L.24.638
BASEMENT (O)R.L.21.338
3600
3300
3300
SO
UT
H T
ITLE
BO
UN
DA
RY
51-5
9 K
EN
SIN
GT
ON
RO
AD
TIT
LE
BO
UN
DA
RY
63
KE
NS
ING
TO
N R
OA
D
2810 2430
10m HEIGHT LIMIT AT BUILDING LINE
(SHOWN DASHED)
BASEMENT
(SHOWN DASHED)
CR01
CR01
C01
GL01
GL01
C01
R.L. 32.338
10195
MT01
METAL DRIVEWAY ENTRY DOOR
MT01
GL01
R.L. 31.538
8075
7800
800
LIFT OVERRUN
A
B
C
E
J
L
M
N
O
G
50
48 54
133
73
7167
65
63
51
-
59
D
F
H
K
BASEMENT 2 / TERRACE R.L.13.800
BASEMENT 1/LEVEL -1 (E/F/J) R.L.17.400
ROOF (O)R.L.31.538
LEVEL 1 (O)R.L.27.938
GROUND (O)R.L.24.638
BASEMENT (O)R.L.21.338
WE
ST
TIT
LE
BO
UN
DA
RY
MID
SO
UT
H T
ITLE
BO
UN
DA
RY
7380 7615
3600
3300
3300
3600
PROPOSED 2.2m HIGH BOUNDARY FENCE
(SHOWN DASHED)
K E
N S
I N
G T
O N
R
O A
D
TIT
LE
BO
UN
DA
RY
BASEMENT (SHOWN DASHED)
10m HEIGHT LIMIT AT BUILDING LINE
(SHOWN DASHED)
BASEMENT (SHOWN DASHED)
CR01
CR01
C01
C01
C01
C01
CR01
CR01
C01SCR01 SCR01 SCR01
C01GL01 GL01 GL01
C01
C01
CR01
CR01
C02 GL01GL01 C02
26000
R.L. 33.800
R.L. 32.338
C01
C01
C01
ROOF (N) R.L.33.000
LEVEL 2 (N) R.L.29.400
LEVEL 1 (N) R.L.26.100
GROUND (N) R.L.22.800
3600
3300
3300
5400
R.L. 33.000
R.L. 31.538
SCR01
SCR01
PROPOSED GROUND LEVEL BEYOND
EXISTING NATURAL GROUND LEVEL AT TITLE BOUNDARY
SCR02
8145
6550
8075
800
LIFT OVERRUN
800
LIFT OVERRUN
ROOF PLANT 1500h
PLANT SCREEN
SCR02
GL01
GL01SCR01
SCR01
BASEMENT 2 / TERRACE R.L.13.800
GROUND (M) R.L.21.800
LEVEL 1 (M) R.L.25.100
LEVEL 2 (M) R.L.28.400
ROOF (M) R.L.32.000
BASEMENT 1/LEVEL -1 (E/F/J) R.L.17.400
3600
3300
3300
4400
3600
SO
UT
H T
ITLE
BO
UN
DA
RY
MID
TIT
LE
BO
UN
DA
RY
3185
51-5
9 K
EN
SIN
GT
ON
RO
AD
EXISTING 3M HIGH
BOUNDARY FENCE
(SHOWN DASHED)
51-59 KENSINGTON RD
BASEMENT (SHOWN DASHED)
10m HEIGHT LIMIT AT BUILDING LINE
(SHOWN DASHED)
GL01 GL01
CR01
CR01
C01
C01
C01
C01
C02 GL01
SCR01
21070
C01
C01
C01
RE01
GL01
3000
R.L. 32.800
R.L. 32.000
CR01
GL01
BUILDING M LOBBY
GL01
GL01
GL01
GL01
PROPOSED GROUND LEVEL BEYOND
EXISTING NATURAL GROUND LEVEL AT
TITLE BOUNDARY
SCR02
9015
8465
8725
LIFT OVERRUN
800
ROOF PLANT 1500h
PLANT SCREEN
SCR02
GL01
ROOF (O)R.L.31.538
LEVEL 1 (O)R.L.27.938
GROUND (O)R.L.24.638
BASEMENT (O)R.L.21.338
EA
ST
TIT
LE
BO
UN
DA
RY
PR
OP
OS
ED
SU
BD
IVIS
ION
27207810
K E
N S
I N
G T
O N
R
O A
D
3300
3300
3600
PROPOSED 2.2m HIGH BOUNDARY FENCE
(SHOWN DASHED)
10m HEIGHT LIMIT AT BUILDING LINE
(SHOWN DASHED)
BASEMENT (SHOWN DASHED)
CR01
CR01
C01
C01
C01
C01
GL01
GL01
GL01
GL01
R.L. 32.338
28000
MT01
C01
C01
C01
SCR01
R.L. 31.538
PROPOSED GROUND LEVEL BEYOND
EXISTING NATURAL GROUND LEVEL
AT TITLE BOUNDARY
7800
7585 7595
6585
800
LIFT OVERRUN
MATERIAL SCHEDULE
NATURAL CEMENT RENDER
SANDBLASTED CONCRETE
TEXTURED, STRIATED CONCRETE
RAMMED EARTH
CLEAR GLAZING
25% TRANSPARENT GLASS
BRONZE-COLOURED METAL
SCREEN SCHEDULE
SCR01BRONZE-COLOURED METAL SCREEN, 25%
OPEN TO 1.7m ABOVE FFL - REFER TO
TP-406 FOR SCREEN DETAIL
C01
C02
RE01
CR01
GL01
MT01
GL02
SCR02ROOF PLANT SCREEN BRONZE COLOURED PERFORATED MESH
Builders / Contractors shall verify all dimensions before any work
commences. Dimensions shown are nominal. Figured dimensions
shall take precedence over scaled dimensions. Any discrepancies
are to be made known to the Architects / Designers studio prior to
any works commencing on site. All shop drawings shall be
submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205
© Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4
31 Flinders Lane
Melbourne VIC
3000 Australia
PO Box 18069
Collins Street East
Melbourne VIC
8003 Australia
+61 3 9665 2300
carr.net.au
Based on Drawings Received:
As indicated
1
Alexandra Avenue - BUILDING
ELEVATIONS SHEET 03
18094
TP-202
16.11.18
TK
135-141 Alexandra Avenue, South Yarra
DB
SCALE 1 : 250SK - 113
SOUTH ELEVATION1
SCALE 1 : 250SK - 113
EAST ELEVATION4SCALE 1 : 250SK - 113
SOUTH ELEVATION3
SCALE 1 : 250SK - 113
EAST ELEVATION2
SCALE 1 : 250SK - 113
NORTH ELEVATION5
01
02
03
04
05
XX BUILDING HEIGHT ABOVE NGL
(NGL TAKEN AT BUILDING LINE CORNERS)
1 18/01/2018 DB RFI RESPONSE
-
ROOF (K) R.L.28.300
LEVEL 2 (K) R.L.24.700
LEVEL 1 (K) R.L.21.400
GROUND (K) R.L.18.100
TIT
LE
BO
UN
DA
RY
R.L. 32.150
R.L. 28.300
R O
C K
L E
Y
R O
A D
PROPOSED 2.2m HIGH BOUNDARY FENCE (SHOWN
DASHED)
2330
TIT
LE
BO
UN
DA
RY
SIGHT LINE
26205
4045
R.L. 29.100
BUILDING OUTLINE OF
APPROVED SCHEME
R.L. 20.640
1500
3300
3300
3600
BUILDING J BEYOND
11770
C01GL01 GL01 GL01 GL01 GL01
CR01
C01
C01GL01 GL01 GL01 GL01 GL01
CR01
C01
C01GL01 GL01 GL01 GL01 GL01
CR01
MT01
MT01
C01
C01
C01
C01
C01
C01
PROPOSED GROUND LEVEL
EXISTING NATURAL GROUND LEVEL AT TITLE BOUNDARY
R.L. 18.600
3600
3300
2800
SCR02
9990
9170
9300
LIFT OVERRUN
800
ROOF PLANT 1500h
PLANT SCREEN
SCR02
ROOF (K) R.L.28.300
LEVEL 2 (K) R.L.24.700
LEVEL 1 (K) R.L.21.400
GROUND (K) R.L.18.100
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
3300
3300
3600
BUILDING OUTLINE OF
APPROVED SCHEME
R.L. 32.150
R.L. 33.600
R.L. 29.100
R.L. 28.300
17275
8660
BUILDING J BEYOND
SCR01
CR01
C01
CR01
C01
CR01
C01
CR01
C01
SCR02
9990
9120
LIFT OVERRUN
800
ROOF PLANT 1500h
PLANT SCREEN
SCR02
A
B
C
E
J
L
M
N
O
G
50
48 54
133
73
7167
65
63
51
-
59
D
F
H
K
MATERIAL SCHEDULE
NATURAL CEMENT RENDER
SANDBLASTED CONCRETE
TEXTURED, STRIATED CONCRETE
RAMMED EARTH
CLEAR GLAZING
25% TRANSPARENT GLASS
BRONZE-COLOURED METAL
SCREEN SCHEDULE
SCR01BRONZE-COLOURED METAL SCREEN, 25%
OPEN TO 1.7m ABOVE FFL - REFER TO
TP-406 FOR SCREEN DETAIL
C01
C02
RE01
CR01
GL01
MT01
GL02
SCR02ROOF PLANT SCREEN BRONZE COLOURED PERFORATED MESH
0
SCALE 1:50
0.5 1.0 2.5m
NORTH
Builders / Contractors shall verify all dimensions before any work
commences. Dimensions shown are nominal. Figured dimensions
shall take precedence over scaled dimensions. Any discrepancies
are to be made known to the Architects / Designers studio prior to
any works commencing on site. All shop drawings shall be
submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205
© Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4
31 Flinders Lane
Melbourne VIC
3000 Australia
PO Box 18069
Collins Street East
Melbourne VIC
8003 Australia
+61 3 9665 2300
carr.net.au
As indicated
1
Alexandra Avenue - BUILDING
ELEVATIONS SHEET 04 - ROCKLEY RD STUDY
18094
TP-203
16.11.18
ZB
135-141 Alexandra Avenue, South Yarra
AS
SCALE 1 : 200SK - 113
ROCKLEY RD STUDY - NORTH WEST ELEVATION2SCALE 1 : 200SK-101
ROCKLEY RD STUDY - SOUTH WEST ELEVATION1
12
XX BUILDING HEIGHT ABOVE NGL
(NGL TAKEN AT BUILDING LINE CORNERS)
1 18/01/2018 DB RFI RESPONSE
-
BUILDING C IN ELEVATION BUILDING F & E IN ELEVATION
BASEMENT 2 / TERRACE R.L.13.800
TIT
LE
BO
UN
DA
RY
BASEMENT 2
BASEMENT 1
APT M.GF 01
APT M.L1 01
APT M.L2 01
SETBACK
3570
SETBACK
3455
13275
APT M.GF 02
APT M.L1 02
APT M.L2 02
R.L. 30.900
GROUND (M) R.L.21.800
LEVEL 1 (M) R.L.25.100
LEVEL 2 (M) R.L.28.400
ROOF (M) R.L.32.000
BASEMENT 1/LEVEL -1 (E/F/J) R.L.17.400
3600
600
3000
600
2700
600
2700
MEADOW
C01
CR01
CR01
CR01
C01
C02
GL02 GL02
GL02 GL02
C01
C01
C02
R.L. 32.000
RE01
21070
FENCE
LEVEL 2 FCL (M) R.L.31.400
LEVEL 1 FCL (M) R.L.27.800
GROUND FCL (M) R.L.24.500
800
R.L. 31.700LIFT OVERRUN
3600
3300
3300
R.L. 21.681R.L. 22.105
SCR02
SCR02
ROOF PLANT 1500h
PLANT SCREEN
SCR02 ROOF PLANT 1500h
PLANT SCREEN
SCR02
BASEMENT 3R.L.2.650
TIT
LE
BO
UN
DA
RY
BASEMENT 3
ENTRANCE LOBBY
R.L. 10.350
10M HEIGHT LIMIT
(SHOWN DASHED)
R.L. 16.500
SETBACK
8535
SETBACK
6555
27780
VISITOR PARKING/LOADING 3500
1:16.0
RAMP
6700
R.L. 2.800R.L. 2.800
OBSERVED WATER LEVEL SHOWN IN
DASHED BLUE LINE
R.L. 2.350
ROOF (E/F/J)R.L.30.900
LEVEL 2 (E/F/J)R.L.27.300
LEVEL 1 (E/F/J)R.L.24.000
GROUND (E/F/J)R.L.20.700
BASEMENT 1/LEVEL -1 (E/F/J)R.L.17.400
A L
E X
A N
D R
A
A V
E N
U E
LEVEL 1 (B)R.L.9.600
GROUND (B)R.L.6.300
LEVEL 2 (B)R.L.12.900
ROOF (B)R.L.16.500
3600
3300
3300
ROOF (K)R.L.28.300
LEVEL 2 (K)R.L.24.700
LEVEL 1 (K)R.L.21.400
GROUND (K)R.L.18.100
PEDESTRIAN
ENTRY
28375
GL01 GL01GL01 GL01
GL01 GL01GL01 GL01
GL01
C01 C01C01
C01
C01
CR01
CR01
CR01
C01
RE01GL01C02
2500
RECESSED PLANTER MIN. 1m DEPTH
2500
3600
3300
3300
3650
3600
3300
3300
3300
800
R.L. 17.300LIFT OVERRUN
EXISTING NATURAL GROUND LEVEL
(SHOWN DASHED)
R.L. 27.300
R.L. 13.800
POOL TERRACE
R.L. 13.800
CR01
C01C01 GL01
GL01C01
C02
RE01
RE01GL01
RE01
CR01
CR01
RE01
C01
MT01
MT01
RE01
C02
R.L. 28.300
R.L. 19.000
GROUND (FOYER/C/D) R.L.6.550
BASEMENT 3 R.L.2.650
BASEMENT 3
FOYER
R.L. 2.350
4590
TIT
LE
BO
UN
DA
RY
R.L. 2.800R.L. 2.800
OBSERVED WATER LEVEL SHOWN IN
DAHSED BLUE LINE
LOBBY BEYOND
P.O.S
BEYOND
6740
R.L. 17.950
R.L. 30.900
VISITOR PARKING/LOADING
ROOF (E/F/J) R.L.30.900
LEVEL 2 (E/F/J) R.L.27.300
LEVEL 1 (E/F/J) R.L.24.000
GROUND (E/F/J) R.L.20.700
BASEMENT 1/LEVEL -1 (E/F/J) R.L.17.400
LEVEL 1 (C/D) R.L.10.350
LEVEL 2 (C/D) R.L.13.650
LEVEL 3 (C/D) R.L.16.950
ROOF (C/D) R.L.20.550
A L
E X
A N
D R
A
A V
E N
U E
10m HEIGHT LIMIT IN DISTANCE (GREY DASH)
10m HEIGHT LIMIT IN DISTANCE (GREY DASH)
BUILDING PORTION WITHIN 10m
HEIGHT LIMIT
BUILDING PORTION WITHIN 10m
HEIGHT LIMIT
CR01
CR01
CR01
C01GL01 GL01C01 GL01C01
C01GL01
C01
C01 C01 GL01 GL01C01
C01GL01 C02
C01
GL01
GL01
GL01
C01C01
C01C01
C01
C02C02
C01
CR01
CR01
MT01
2500
RECESSED PLANTER 1m DEEP
R.L. 20.550
R.L. 27.300
3900
3800
3300
3300
3600
3300
3300
3600
800
R.L. 21.350LIFT OVERRUN
R.L. 13.800
EXISTING NATURAL
GROUND LEVEL
BASEMENT 2 / TERRACER.L.13.800
10m HEIGHT LIMIT
POOL TERRACE
TIT
LE
BO
UN
DA
RY
BASEMENT 1
BASEMENT 2
MEADOW
APT J.GF
APT J.L1
APT J.L2
APT M.GF 02
APT M.L1 02
APT M.L2 02
APT M.GF 01
APT M.L1 01
APT M.L2 01
SETBACK
3730
P.O.S
P.O.S
P.O.S GROUND (M)R.L.21.800
LEVEL 1 (M)R.L.25.100
LEVEL 2 (M)R.L.28.400
ROOF (M)R.L.32.000
ROOF (E/F/J)R.L.30.900
LEVEL 2 (E/F/J)R.L.27.300
LEVEL 1 (E/F/J)R.L.24.000
GROUND (E/F/J)R.L.20.700
BASEMENT 1/LEVEL -1 (E/F/J)R.L.17.400
10m HEIGHT LIMIT IN DISTANCE (GREY DASH)
BUILDING PORTION WITHIN 10m
HEIGHT LIMIT
R.L. 32.800R.L. 33.000R.L. 32.850
R.L. 31.700
GL01
GL01
GL01 GL01C01 C01
C01 C01
C01 C01
GL01 GL01 GL01
GL01
GL01
CR01
CR01
CR01
C01 GL01
CR01
GL01 GL01 C01
GL01
MT01
RE01
CR01
R.L. 32.000
LEVEL 2 FCL (M)R.L.31.400
LEVEL 1 FCL (M)R.L.27.800
GROUND FCL (M)R.L.24.500
LEVEL 2 FCL (E/F/J)R.L.30.300
LEVEL 1 FCL (E/F/J)R.L.26.700
GROUND FCL (E/F/J)R.L.23.400
600
3000
600
2700
600
2700
3300
3600
600
3000
600
2700
600
2700
800
800
LIFT OVERRUN
LIFT OVERRUN
3600
3300
3300
3600
3300
3300
R.L. 17.808
R.L. 22.085
SCR02
SCR02
SCR02
ROOF PLANT 1500h
PLANT SCREEN
SCR02
ROOF PLANT 1500h
PLANT SCREEN
SCR02
ROOF PLANT 1500h
PLANT SCREEN
REFER TO TP-406 FOR
DETAILS
A
B
C
E
J
L
M
N
O
G
50
48 54
133
73
7167
65
63
51
-
59
D
F
H
K
MATERIAL SCHEDULE
NATURAL CEMENT RENDER
SANDBLASTED CONCRETE
TEXTURED, STRIATED CONCRETE
RAMMED EARTH
CLEAR GLAZING
25% TRANSPARENT GLASS
BRONZE-COLOURED METAL
SCREEN SCHEDULE
SCR01BRONZE-COLOURED METAL SCREEN, 25%
OPEN TO 1.7m ABOVE FFL - REFER TO
TP-406 FOR SCREEN DETAIL
C01
C02
RE01
CR01
GL01
MT01
GL02
SCR02ROOF PLANT SCREEN BRONZE COLOURED PERFORATED MESH
Builders / Contractors shall verify all dimensions before any work
commences. Dimensions shown are nominal. Figured dimensions
shall take precedence over scaled dimensions. Any discrepancies
are to be made known to the Architects / Designers studio prior to
any works commencing on site. All shop drawings shall be
submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205
© Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4
31 Flinders Lane
Melbourne VIC
3000 Australia
PO Box 18069
Collins Street East
Melbourne VIC
8003 Australia
+61 3 9665 2300
carr.net.au
Based on Drawings Received:
As indicated
1
Alexandra Avenue - BUILDING
SECTION - SHEET 01
18094
TP-300
16.11.18
LR, TK
135-141 Alexandra Avenue, South Yarra
DB
SCALE 1 : 250SK-120
SECTION 22
2
SCALE 1 : 250SK -XX
SECTION 11
1
1 18/01/2018 DB RFI RESPONSE
-
BASEMENT 3 R.L.2.650
3
TP-301
B17
RESC
ODE
TIT
LE
BO
UN
DA
RY
(IN
AN
GLE
)
A L
E X
A N
D R
A
A V
E N
U E
APT B.L1
APT B.L2
APT B.GF
BASEMENT 3
R.L. 16.500
10M HEIGHT LIMIT SHOWN IN
DASHED LINE
TIT
LE
BO
UN
DA
RY
SETBACK
8475
SETBACK
6500
R.L. 2.800
OBSERVED WATER LEVEL SHOWN IN
BLUE DASHED LINE
P.O.S
P.O.S
P.O.S
BUILDING A IN BACKGROUND
133 ALEXANDRA AVE SHOWN BEYOND
IN LIGHTER GREY
R.L. 19.610
LOWER HEAD HEIGHT
CLEARENCE SHOWN
BEYOND
LOBBY
SERVICES
SETBACK
6010
SETBACK
13040
SETBACK
6010
P.O.S
LEVEL 1 (B) R.L.9.600
GROUND (B) R.L.6.300
LEVEL 2 (B) R.L.12.900
ROOF (B) R.L.16.500
600
3000
600
2700
600
2700
3650
28375
CR01
C01
C01
CR01
CR01
SERVICES
DROP OFF
2500
RECESSED PLANTER 1000MM
DEPTH
FENCE
3600
2800
LEVEL 2 FCL (B) R.L.15.900
LEVEL 1 FCL (B) R.L.12.300
GROUND FCL (B) R.L.9.000
3600
3300
3300
EXISTING NGL SHOWN
IN DASHED LINE
BASEMENT 3 R.L.2.650
3
TP-301
A L
E X
A N
D R
A
A V
E N
U E
TIT
LE
BO
UN
DA
RY
(IN
AN
GLE
)
TIT
LE
BO
UN
DA
RY
(IN
AN
GLE
)
APT A.GF
APT A.L1
APT A.L2
BASEMENT 3
10M HEIGHT LIMIT SHOWN IN RED
DASHED LINE
SETBACK
4145
R.L. 5.350
R.L. 10.863
BASEMENT SETBACK
6945
R.L. 2.800
OBSERVED WATER LEVEL SHOWN IN BLUE
DASHED LINE
STORAGE / SERVICES
R.L. 2.800
P.O.S
P.O.S
P.O.S
2500
650
133 ALEXANDRA AVE SHOWN
BEYOND IN LIGHTER GREY
R.L. 19.610
R.L. 16.460
P.O.S
ROOF (A) R.L.15.550
LEVEL 2 (A) R.L.11.950
LEVEL 1 (A) R.L.8.650
GROUND (A) R.L.5.350
600
3000
600
2700
600
2700
2700
5805
28490
SERVICES
R.L. 15.550
R.L. 2.350
650mm HIGH PLANTER WITH
1m HIGH BALUSTRADE
650
GROUND FCL (A) R.L.8.050
LEVEL 1 FCL (A) R.L.11.350
LEVEL 2 FCL (A) R.L.14.950 3600
3300
3300
EXISTING NGL SHOWN IN
DASHED LINE
GROUND (FOYER/C/D) R.L.6.550
BASEMENT 3R.L.2.650BASEMENT 3 R.L.2.650
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
2.
TP-300
11
TP-303
4
TP-301
5
TP-301
RAMP
RAMP
ENTRANCE
LOBBYAPT B.GF
APT A.GF
APT A.L1
APT A.L2
APT B.L1
APT B.L2
APT C.L1
APT C.L2
APT D.L1
APT D.L2
APT C.L3
SETBACK
4975
10M HEIGHT LIMIT SHOWN IN
DASHED LINE
R.L. 5.350
SETBACK
5630
SETBACK
8000
SETBACK
3065
BASEMENT 3
SERVICES/STORAGE
5650 4000
CONCIERGE/
LOUNGE
C LOBBY
BUILDING 1
WASTE
R.L. 2.850
RAMP SHOWN IN ANGLE
7260
1:10 RAMP
6400
SERVICES
BEYOND
R.L. 15.550
R.L. 16.500
SETBACK
2400
R.L. 2.800 R.L. 2.800
OBSERVED WATER LEVEL SHOWN IN
BLUE DASHED LINE
OBSERVED WATER LEVEL SHOWN IN
BLUE DASHED LINE
MID LEVEL LOBBY
1
TP-300
STAIR / LIFT
CORE BEYOND
R.L. 19.610
LEVEL 1 (C/D) R.L.10.350
LEVEL 2 (C/D) R.L.13.650
LEVEL 3 (C/D) R.L.16.950
ROOF (C/D) R.L.20.550
LEVEL 1 (B)R.L.9.600
GROUND (B)R.L.6.300
LEVEL 2 (B)R.L.12.900
ROOF (B)R.L.16.500
ROOF (A)R.L.15.550
LEVEL 2 (A)R.L.11.950
LEVEL 1 (A)R.L.8.650
GROUND (A)R.L.5.350
11130 11140
OFFICE
133757800
R.L. 20.550
GL01
CR01
C01
SERVICES
BEYOND
LEVEL 3 FCL (C/D) R.L.19.950
LEVEL 2 FCL (C/D) R.L.16.350
LEVEL 1 FCL (C/D) R.L.13.050
GROUND FCL (FOYER/C/D) R.L.9.750
3900
3200
600
2700
600
2700
600
3000
600
LEVEL 2 FCL (B)R.L.15.900
LEVEL 1 FCL (B)R.L.12.300
GROUND FCL (B)R.L.9.000
GROUND FCL (A)R.L.8.050
LEVEL 1 FCL (A)R.L.11.350
LEVEL 2 FCL (A)R.L.14.950
600
3000
600
2700
600
2700
600
3000
600
2700
600
2700
2700
950
3650
800
R.L. 21.350
800
1750
LIFT OVERRUNR.L. 17.300
LIFT OVERRUN
3800
3300
3300
3600
3600
3300
3300
3600
3300
3300
EXISTING NATURAL GROUND LEVEL
SHOWN IN DASHED LINE
A
B
C
E
J
L
M
N
O
G
50
48 54
133
73
7167
65
63
51
-
59
D
F
H
K
MATERIAL SCHEDULE
NATURAL CEMENT RENDER
SANDBLASTED CONCRETE
TEXTURED, STRIATED CONCRETE
RAMMED EARTH
CLEAR GLAZING
25% TRANSPARENT GLASS
BRONZE-COLOURED METAL
SCREEN SCHEDULE
SCR01BRONZE-COLOURED METAL SCREEN, 25%
OPEN TO 1.7m ABOVE FFL - REFER TO
TP-406 FOR SCREEN DETAIL
C01
C02
RE01
CR01
GL01
MT01
GL02
SCR02ROOF PLANT SCREEN BRONZE COLOURED PERFORATED MESH
Builders / Contractors shall verify all dimensions before any work
commences. Dimensions shown are nominal. Figured dimensions
shall take precedence over scaled dimensions. Any discrepancies
are to be made known to the Architects / Designers studio prior to
any works commencing on site. All shop drawings shall be
submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205
© Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4
31 Flinders Lane
Melbourne VIC
3000 Australia
PO Box 18069
Collins Street East
Melbourne VIC
8003 Australia
+61 3 9665 2300
carr.net.au
Based on Drawings Received:
As indicated
1
Alexandra Avenue - BUILDING
SECTION - SHEET 02
18094
TP-301
16.11.18
LR, TK
135-141 Alexandra Avenue, South Yarra
DB
SCALE 1 : 250SK -XX
SECTION 44SCALE 1 : 250SK -XX
SECTION 55
4
5
SCALE 1 : 250SK-120
SECTION 33
3
1 18/01/2018 DB RFI RESPONSE
-
B17 R
ESCODE
BUILDING M IN SECTION
B1
7 R
ES
CO
DE
B17 R
ESCODE
B1
7 R
ES
CO
DE
BUILDING E & F IN SECTION
B17 R
ESCODE
B1
7 R
ES
CO
DE
BUILDING O IN SECTION
BASEMENT 2 / TERRACE R.L.13.800
BASEMENT 1(M) R.L.17.600
GROUND (M) R.L.21.800
LEVEL 1 (M) R.L.25.100
LEVEL 2 (M) R.L.28.400
ROOF (M) R.L.32.000
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
APT M.L2 01
APT M.L1 01
APT M.GF 01
BASEMENT 1
BASEMENT 2
10M HEIGHT LIMIT
46 ROCKLEY RD
51-59 KENSINGTON RD
40205410
LIFT
CORE
C01
C01
CR01
CR01
C02
15585
Sim
1
TP-500
R.L. 32.800
R.L. 32.000
LEVEL 2 FCL (M) R.L.31.400
LEVEL 1 FCL (M) R.L.27.800
GROUND FCL (M) R.L.24.500
LEVEL 1 FCL (O)R.L.30.938
GROUND FCL (O)R.L.27.338
600
3000
600
2700
600
2700
4200
3800
3600
3300
3300
8000
LIFT
OVERRUN
800
EXISTING NATURAL GROUND SHOWN IN DASH
SCR02
ROOF PLANT 1500h
PLANT SCREEN
SCR02
GROUND (FOYER/C/D) R.L.6.550
BASEMENT 3 R.L.2.650
BASEMENT 2 / TERRACE R.L.13.800
ROOF (E/F/J) R.L.30.900
LEVEL 2 (E/F/J) R.L.27.300
LEVEL 1 (E/F/J) R.L.24.000
GROUND (E/F/J) R.L.20.700
BASEMENT 1/LEVEL -1 (E/F/J) R.L.17.400
LEVEL 1 (C/D) R.L.10.350
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
APT F.L-1
APT F.GF
APT F.L1
APT E.L-1
APT E.GF
APT E.L1
CAR LIFT 2CAR LIFT 1LOBBY
LOADING / LOBBY
APT E.L2
10M HEIGHT LIMIT AT SECTION CUT
67
KENSINGTON RD
POS
71 KENSINGTON RD
IN THE
BACKGROUND
54
ROCKLEY RD
PARKING
GOODS
LIFT
16700 4835
POOL
TERRACE
10m HEIGHT LIMIT IN DISTANCE (GREY DASH)
BUILDING PORTION WITHIN 10m HEIGHT LIMIT600
3000
600
2700
600
2700
600
2700
3600
R.L. 30.900
LOBBY
LOBBY
CR01
CR01
MT01
C01
C02
RE01
C01
Sim
1
TP-405
LEVEL 2 FCL (E/F/J) R.L.30.300
LEVEL 1 FCL (E/F/J) R.L.26.700
GROUND FCL (E/F/J) R.L.23.400
BASEMENT 1/LEVEL -1 FCL (E/F/J) R.L.20.100
3600
3300
3300
3300
TERRACE COMMUNAL OPEN SPACE
EXISTING NATURAL
GROUND SHOWN IN DASH
A
B
C
E
J
L
M
N
O
G
50
48 54
133
73
7167
65
63
51
-
59
D
F
H
K
MATERIAL SCHEDULE
NATURAL CEMENT RENDER
SANDBLASTED CONCRETE
TEXTURED, STRIATED CONCRETE
RAMMED EARTH
CLEAR GLAZING
25% TRANSPARENT GLASS
BRONZE-COLOURED METAL
SCREEN SCHEDULE
SCR01BRONZE-COLOURED METAL SCREEN, 25%
OPEN TO 1.7m ABOVE FFL - REFER TO
TP-406 FOR SCREEN DETAIL
C01
C02
RE01
CR01
GL01
MT01
GL02
SCR02ROOF PLANT SCREEN BRONZE COLOURED PERFORATED MESH
ROOF (O) R.L.31.538
LEVEL 1 (O) R.L.27.938
GROUND (O) R.L.24.638
BASEMENT (O) R.L.21.338
LEVEL 1 FCL (O) R.L.30.938
GROUND FCL (O) R.L.27.338
APT O.L1
APT O.GF
BASEMENT
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
10M HEIGHT LIMIT
63KENSINGTON RD
51-59KENSINGTON RD
3300
3300
3600
2700
600
3000
600
10195
2200 2725
NORTH
Builders / Contractors shall verify all dimensions before any work
commences. Dimensions shown are nominal. Figured dimensions
shall take precedence over scaled dimensions. Any discrepancies
are to be made known to the Architects / Designers studio prior to
any works commencing on site. All shop drawings shall be
submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205
© Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4
31 Flinders Lane
Melbourne VIC
3000 Australia
PO Box 18069
Collins Street East
Melbourne VIC
8003 Australia
+61 3 9665 2300
carr.net.au
Based on Drawings Received:
As indicated
1
Alexandra Avenue - BUILDING
SECTION - SHEET 03
18094
TP-302
16.11.18
LR, TK
135-141 Alexandra Avenue, South Yarra
DB
SCALE 1 : 250
SECTION 88SCALE 1 : 250SK-120
SECTION 77
6
7
8
SCALE 1 : 250SK-120
SECTION 61
1 18/01/2018 DB RFI RESPONSE
-
BUILDING G & H IN SECTIONBUILDING N IN SECTION
B1
7 R
ES
CO
DE
BUILDING E & F IN SECTION BUILDING C IN SECTION
BUILDING J IN SECTION BUILDING G & H IN SECTION
B1
7 R
ES
CO
DE
B17 R
ESCODE
BASEMENT 2 / TERRACE R.L.13.800
TIT
LE
BO
UN
DA
RY
(IN
AN
GLE
)
SETBACK
4115 8495
APT G.GF
APT G.L1
APT G.L2
BASEMENT 1
BASEMENT 2
R.L. 32.850
R.L. 33.800
APT N.GF
APT N.L1
APT N.L2
10m HEIGHT LIMIT
RAMP CONNECT BETWEEN BASEMENT 1 &
BASEMENT 2 SHOWED IN ANGLESETBACK
3640
BASEMENT 1/LEVEL -1 (E/F/J) R.L.17.400
LIFT
CORE N
LIFT
CORE H/G
3600
51-59
KENSINGTON RD
P.O.S
P.O.S
P.O.S
LOBBY
BUILDING N
LOBBY
BUILDING N
BASEMENT 1
BASEMENT 2
R.L. 33.000
R.L. 29.250
ROOF (N) R.L.33.000
LEVEL 2 (N) R.L.29.400
LEVEL 1 (N) R.L.26.100
GROUND (N) R.L.22.800
1800
LEVEL 2 FCL (N) R.L.32.400
LEVEL 1 FCL (N) R.L.28.800
GROUND FCL (N) R.L.25.500
600
3000
600
2700
600
2700
2100
33005
400
800
3600
3300
3300
800
R.L. 33.650
SCR02
LIFT OVERRUNLIFT OVERRUN
ROOF PLANT 1500h
PLANT SCREEN
SCR02
APT F.L-1
APT F.GF
APT F.L1
APT E.L2
9000
R.L. 2.800
ROOF (E/F/J)R.L.30.900
LEVEL 2 (E/F/J)R.L.27.300
LEVEL 1 (E/F/J)R.L.24.000
GROUND (E/F/J)R.L.20.700
BASEMENT 1/LEVEL -1 (E/F/J)R.L.17.400
CAR LIFT
LIFT
CORE E/F
GROUND FLOOR (G/H) R.L.22.650
LEVEL 1 (G/H) R.L.25.950
LEVEL 2 (G/H) R.L.29.250
ROOF (G/H) R.L.32.850 R.L. 31.700
LOBBY
BUILDING E&F
GOODS MID LEVELS LIFTBEYOND
R.L. 30.900
CR01
C01
CR01
MT01
MT01
CR01
C01
C01
CR01
C01
SERVICES
SUBSTATION
LEVEL 2 FCL (E/F/J)R.L.30.300
LEVEL 1 FCL (E/F/J)R.L.26.700
GROUND FCL (E/F/J)R.L.23.400
BASEMENT 1/LEVEL -1 FCL (E/F/J)R.L.20.100
LEVEL 2 FCL (G/H) R.L.32.250
LEVEL 1 FCL (G/H) R.L.28.650
GROUND FLOOR FCL (G/H) R.L.25.350
600
3000
600
2700
600
2700
3600
3300
3300
600
3000
600
2700
600
2700
600
2700
3600
3300
3300
3300
LIFT OVERRUN
800
GROUND (FOYER/C/D)R.L.6.550
BASEMENT 3R.L.2.650
A L
E X
A N
D R
A
A V
E N
U E
SERVICES / STORE
APT C.GF
APT C.L1
APT C.L2
TIT
LE
BO
UN
DA
RY
RAMP
4535
10m HEIGHT LIMIT SHOWN IN RED
DASHED LINE
MAIL /
SERVICES
3500
3600
R.L. 2.800
OBSERVED WATER
LEVEL SHOWN IN BLUE
DASHED LINE
LEVEL 1 (C/D)R.L.10.350
LEVEL 2 (C/D)R.L.13.650
LEVEL 3 (C/D)R.L.16.950
ROOF (C/D)R.L.20.550
LIFT
CORE
C/D
600
3000
600
2700
600
2700
600
3200
3900
3600
3300
3300
3800
P.O.S
P.O.S
P.O.S
BASEMENT
ENTRY
R.L. 20.550
LOBBY
CR01
MT01
C01
C01
CR01
LOBBY
C/D
LOBBY
C/D
LOBBY
C/D
OFFICE
R.L. 21.350
3600
LEVEL 3 FCL (C/D)R.L.19.950
LEVEL 2 FCL (C/D)R.L.16.350
LEVEL 1 FCL (C/D)R.L.13.050
GROUND FCL (FOYER/C/D)R.L.9.750800
LIFT OVERRUN
EXISTING NATURAL GROUND
LEVEL SHOWN IN DASH
A
B
C
E
J
L
M
N
O
G
50
48 54
133
73
7167
65
63
51
-
59
D
F
H
K
BASEMENT 2 / TERRACE R.L.13.800
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY5580 7665
APT K.L2 02
APT K.L1 02
APT K.GF 02
POOL
10M HEIGHT LIMIT
ROOF (K) R.L.28.300
LEVEL 2 (K) R.L.24.700
LEVEL 1 (K) R.L.21.400
GROUND (K) R.L.18.100
600
3000
600
2700
600
2700
4300
1300
50
ROCKLEY RD
54
ROCKLEY RD
POOL R.L.12.500
R.L. 29.100
BASEMENT 2
LIFTLOBBY
LEVEL 2 (N) R.L.29.400
LEVEL 1 (N) R.L.26.100
GROUND (N) R.L.22.800
R.L. 28.300
PROPOSED 2.2m HIGH FENCE
P.O.S
P.O.S
P.O.S
LEVEL 2 FCL (K) R.L.27.700
LEVEL 1 FCL (K) R.L.24.100
GROUND FCL (K) R.L.20.800
5600
3300
3300
3600
LEVEL 1 FCL (N) R.L.28.800
GROUND FCL (N) R.L.25.500
800
LIFT OVERRUN
R.L. 21.400
EXISTING NATURAL GROUND
LEVEL SHOWN IN DASH
SCR02
ROOF PLANT 1500h
PLANT SCREEN
SCR02
BASEMENT 2 / TERRACE R.L.13.800
ROOF (E/F/J) R.L.30.900
LEVEL 2 (E/F/J) R.L.27.300
LEVEL 1 (E/F/J) R.L.24.000
GROUND (E/F/J) R.L.20.700
BASEMENT 1/LEVEL -1 (E/F/J) R.L.17.400
TIT
LE
BO
UN
DA
RY
TIT
LE
BO
UN
DA
RY
BASEMENT 2
APT J.L2
APT J.L1
APT J.L2
APT H.GF APT G.GF
APT H.L1
BASEMENT 1
RAMP
APT G.L1
APT G.L2
SERVICES/
STORAGE
SERVICES/
STORAGE
10M HEIGHT LIMIT
4935 3000
67
KENSINGTON RD
IN THE
BACKGROUND
BUILDING K
IN THE
BACKGROUND
600
3000
600
2700
600
2700
3300
3600
GROUND FLOOR (G/H)R.L.22.650
LEVEL 1 (G/H)R.L.25.950
LEVEL 2 (G/H)R.L.29.250
ROOF (G/H)R.L.32.850
600
3000
600
2700
600
2700
10m HEIGHT LIMIT IN
DISTANCE (GREY DASH)
BUILDING PORTION WITHIN
10m HEIGHT LIMIT
R.L. 32.850
R.L. 30.900
Sim
2
TP-403
Sim
2
TP-404
LEVEL 2 FCL (E/F/J) R.L.30.300
LEVEL 1 FCL (E/F/J) R.L.26.700
GROUND FCL (E/F/J) R.L.23.400
3600
3300
3300
6900
LEVEL 2 FCL (G/H)R.L.32.250
LEVEL 1 FCL (G/H)R.L.28.650
GROUND FLOOR FCL (G/H)R.L.25.350
3600
3300
3300
R.L. 21.854
EXISTING NATURAL GROUND
LEVEL SHOWN IN DASH
SCR02
SCR02
ROOF PLANT 1500h
PLANT SCREEN
SCR02
ROOF PLANT 1500h
PLANT SCREEN
REFER TO TP-406 FOR
DETAILS
MATERIAL SCHEDULE
NATURAL CEMENT RENDER
SANDBLASTED CONCRETE
TEXTURED, STRIATED CONCRETE
RAMMED EARTH
CLEAR GLAZING
25% TRANSPARENT GLASS
BRONZE-COLOURED METAL
SCREEN SCHEDULE
SCR01BRONZE-COLOURED METAL SCREEN, 25%
OPEN TO 1.7m ABOVE FFL - REFER TO
TP-406 FOR SCREEN DETAIL
C01
C02
RE01
CR01
GL01
MT01
GL02
SCR02ROOF PLANT SCREEN BRONZE COLOURED PERFORATED MESH
Builders / Contractors shall verify all dimensions before any work
commences. Dimensions shown are nominal. Figured dimensions
shall take precedence over scaled dimensions. Any discrepancies
are to be made known to the Architects / Designers studio prior to
any works commencing on site. All shop drawings shall be
submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205
© Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4
31 Flinders Lane
Melbourne VIC
3000 Australia
PO Box 18069
Collins Street East
Melbourne VIC
8003 Australia
+61 3 9665 2300
carr.net.au
Based on Drawings Received:
As indicated
1
Alexandra Avenue - BUILDING
SECTION - SHEET 04
18094
TP-303
16.11.18
LR, TK
135-141 Alexandra Avenue, South Yarra
DB
SCALE 1 : 250SK-120
SECTION 1111.
11
SCALE 1 : 250SK-120
SECTION 99SCALE 1 : 250SK-120
SECTION 1010
9
10
1 18/01/2018 DB RFI RESPONSE
-
CASCADING FORMS IN THE LANDSCAPE NARROW SLOT OPENINGS CONTRAST WITH LARGE EXPANSES OF GLAZING. LANDSCAPE WALLS FRAME COURTYARDS
INTEGRATED PLANTING WITHIN BUILT FORM
Builders / Contractors shall verify all dimensions before any work commences. Dimensions shown are nominal. Figured dimensions shall take precedence over scaled dimensions. Any discrepancies are to be made known to the Architects / Designers studio prior to any works commencing on site. All shop drawings shall be submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205 © Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4 31 Flinders Lane Melbourne VIC 3000 Australia
PO Box 18069 Collins Street East Melbourne VIC 8003 Australia
+61 3 9665 2300
Based on Drawings Received:
Alexandra Avenue - BUILDING
MATERIALS / PRECEDENTS
18094
TP-400
16.11.2018
LR, TK
135-141 Alexandra Avenue, South Yarra
DB
-
DEEP TERRACES, COLOURED CONCRETE, BRONZE HANDRAILS
NARROW SLOT OPENINGS BETWEEN BANDED CONCRETE
TEXTURED CONCRETE WALLS CONTRAST WITH SMOOTH CONCRETE SURFACES
Builders / Contractors shall verify all dimensions before any work commences. Dimensions shown are nominal. Figured dimensions shall take precedence over scaled dimensions. Any discrepancies are to be made known to the Architects / Designers studio prior to any works commencing on site. All shop drawings shall be submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205 © Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4 31 Flinders Lane Melbourne VIC 3000 Australia
PO Box 18069 Collins Street East Melbourne VIC 8003 Australia
+61 3 9665 2300
Based on Drawings Received:
Alexandra Avenue - BUILDING
MATERIALS / PRECEDENTS
18094
TP-401
16.11.2018
LR, TK
135-141 Alexandra Avenue, South Yarra
DB
-
C02TEXTURED, STRIATED CONCRETE
GROUND FLOOR OF SELECTED BUILDINGS
CR01EARTH TONE CEMENT RENDER
EXPRESSED BANDING AND SOLID PANELS TO TYPICAL PRECAST WALLING
C01SANDBLASTED CONCRETE
TYPICALLY TO GROUND FLOOR WALLING OF BUILDINGS
SCR01CORRUGATED BRONZE-COLOURED PERFORATED METAL SCREEN VARYING OPACITY
PRIVACY SCREENS AND LANDSCAPE FENCING
GL01CLEAR GLAZING
EXTERNAL WINDOWS
MT01BRONZE-COLOURED METAL
WINDOW FRAMES AND BALUSTRADES
RE01RAMMED EARTH
SELECTED LANDSCAPE WALLING
Builders / Contractors shall verify all dimensions before any work commences. Dimensions shown are nominal. Figured dimensions shall take precedence over scaled dimensions. Any discrepancies are to be made known to the Architects / Designers studio prior to any works commencing on site. All shop drawings shall be submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205 © Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4 31 Flinders Lane Melbourne VIC 3000 Australia
PO Box 18069 Collins Street East Melbourne VIC 8003 Australia
+61 3 9665 2300
Based on Drawings Received:
Alexandra Avenue - BUILDING
MATERIAL PALETTE
18094
TP-402
12.11.2018
LR, TK
135-141 Alexandra Avenue, South Yarra
DB
12/11/2018 ISSUED FOR TOWN PLANNING
-
3600
3300
3300
MATERIAL SCHEDULE
NATURAL CEMENT RENDER
SANDBLASTED CONCRETE
TEXTURED, STRIATED CONCRETE
RAMMED EARTH
BRONZE-COLOURED METAL SCREEN, 25% OPEN TO 1.7m ABOVE FFL
CLEAR GLAZING
BRONZE-COLOURED METAL
C01
C02
RE01
SCR01
GL01
MT01
CR01
A
B
C
E
J
L
M
N
O
G
50
48 54
133
73
7167
65
63
51-
59
D
F
H
K
Builders / Contractors shall verify all dimensions before any work commences. Dimensions shown are nominal. Figured dimensions shall take precedence over scaled dimensions. Any discrepancies are to be made known to the Architects / Designers studio prior to any works commencing on site. All shop drawings shall be submitted for review and manufacture shall not commence prior to the return of stamped shop drawings.
© Carr Architecture ABN 47 099 953 205 © Carr Interiors ABN 56 126 212 575
GENERAL NOTES
Project
Title
Scale @ A1
Project No
Dwg No
Drawn By
Date
Rev
Rev Date Chkd Reason for Issue
Chkd
Level 4 31 Flinders Lane Melbourne VIC 3000 Australia
PO Box 18069 Collins Street East Melbourne VIC 8003 Australia
+61 3 9665 2300
Based on Drawings Received:
As indicated
Alexandra Avenue - BUILDING
ELEVATION STUDY - FACADE
18094
TP-403
16.11.2018
LR, TK
135-141 Alexandra Avenue, South Yarra
DB
BUILDING JEAST ELEVATION
BUILDING HWEST ELEVATION