Since its founding over forty years ago, TPL Communications has lead the industry in developing and manufacturing RF Power Amplifiers that go beyond merely satisfying the requirements of its customers. This focus on providing the best solutions to any customer’s application is embraced at all levels of the company. As a result, TPL has earned an excellent reputation as the premier manufacturer of RF Power Amplifiers.

In 2003, The Employees of TPL Communications purchased the company from its previous owners. As a result we have a personal commitment to expand the company’s success and enhance our long tradition of excellence in products and service to our customers.

Located in Los Angeles, TPL can tailor any of its products to fit the customer’s needs: from mass produced items to a single, specialized unit. This versatility ensures that every customer receives the exact type of equipment required to meet their specifications.

TPL’s line contains a wide variety of products including:

Mobile AmplifiersBase Station AmplifiersRepeater AmplifiersTrunking AmplifiersMobile Amplifier Chargers

Vehicular Battery Chargers

The demand for special types of amplifiers, including those needed for Homeland Security, continues to grow each year. To meet this demand, TPL employs experienced engineers and technicians to ensure delivery of the finest quality products.

TPL History

Page 3: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

It is our mission to maintain an extremely efficient company, delivering high quality products, and generating growth and profitability, while providing impeccable service and best financial value to all customers.

In order to achieve this, we are as concerned with the welfare and satisfaction of our employees as with our customers.

Mission Statement

TPL Communications has over 2,000 customers worldwide, and is proud to have several of the largest and most respected communications companies in the world as clients. These include:

Motorola / Icom / Kenwood / BearCom / Daniels Electronics / Relm / Harris /

Boeing / Point Mugu / E.F. Johnson / NASA /

Lockheed Martin

Page 4: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

4

SPECIFICATIONS

FEATURES

The RXR Series amplifiers are our most popular cost effective, continuous duty power amplifiers. This pack-age will accept any TPL amplifier from VHF Low Band through 960 MHz, with output levels up to 125 watts. All configurations use 7” of vertical rack space and are designed with a flat front panel allowing for installation into a cabinet leaving sufficient room for airflow with the door closed. These amplifiers have a circuit breaker/on-off switch conveniently located on the front panel and can be supplied with or without a switching power supply. This series is the most versatile unit of its type on the market today.

Power Input Standard TPL amplifier input levels, optional 10mW or less.Power Output 50 to 125 watts.Frequencies VHF Low Band, VHF High Band, UHF, 806-960 MHzVoltage 13.8 VDC, 120 or 240 VAC (24 VDC or 48 VDC available).Current Model dependent.Harmonic Attenuation Exceeds FCC and IC specifications.RF Connectors Type N, 50 Ohms.Operating Temperature -30 to +50 degrees C.Duty Cycle Continuous (100%).Weight 7 lbs., 14 lbs., w/power supply.Dimensions 19” W x 7” H x 3” D (without fan), 19” W x 7” H x 5” D (with fan). 8” D w/power supply.

• Accommodates all bands from 29.7 MHz to 960 MHz.• 100% duty cycle operation.• Repeater or base station operation (with solid state bypass relay option).• 19” rack mountable configuration.• Available with or without self-contained switching power supply.• Front panel circuit breaker/on-off switch.• Flat front panel allows for cabinet door closure.• Optional provision for battery backup.• Cost effective design.

RXR SERIES

Page 5: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

RF POWER AMPLIFIERS

VHF Low Band 29.7-50 MHz All VHF Low Band Units with the exception of the PA1-1AC and PA1-1AC3 are available in three different sub-bands (L=29.7 - 36MHz) (M=36 -42MHz) (H=42-50MHz)PA1-1AC-RSF +/-1 MHz Bandwidth 1-4W 1-4W 8 AmpsPA1-1AC3-RSF +/-1 MHz Bandwidth 2-8W 2-8W 8 AmpsPA1-1AE-RXRF 2-4W 60-100W 16 AmpsPA1-1BE-RXRF 4-8W 60-100W 16 AmpsPA1-1CE-RXRF 8-16W 60-100W 16 AmpsPA1-1DE-RXRF 20-40W 60-100W 16 AmpsPA1-1FE-RXRF 40-60W 60-100W 16 Amps

VHF Mid Band 66-88 MHz (For export only - Not FCC or IC Certified)PA2-1AD-RXRF 1-4W 60-100W 14 AmpsPA2-1CD-RXRF 5-25W 40-100W 14 Amps

AERONAUTICAL BAND 118-137 MHzPA3-2AB-AIR-RXRF 1-5W CW 25 W CW/100 W PEPPA3-2AC-AIR-RXRF 1-5W CW 50 W CW/100 W PEP

VHF High Band 136-174 MHzPA3-1AC-RSF 1-5W 15-60W 10 AmpsPA3-1BC-RSF 2-10W 15-60W 10 AmpsPA3-1AE-RXRF 1-5W 40-125W 18 AmpsPA3-1BE-RXRF 2-10W 40-125W 18 AmpsPA3-1DE-RXRF 5-25W 40-125W 18 AmpsPA3-1FE-RXRF 10-50W 40-125W 18 AmpsPA3-2FF-RXHF3 8-15W 150-250W 18 AmpsPA3-2GF-RXHF3 30-60W 150-250W 18 Amps

UHF Band 380-512 MHz All UHF units are available in two different sub-bands (M=400-470 MHz) (H=470-512 MHz) PA6-1AC-RSF 1-5W 15-60W 10 AmpsPA6-1BC-RSF 2-10W 15-60W 10 AmpsPA6-1AE-RXRF 1-5W 40-110W 18 AmpsPA6-1BE-RXRF 2-10W 40-110W 18 AmpsPA6-1DE-RXRF 5-25W 40-110W 18 AmpsPA6-1FE-RXRF 10-50W 40-110W 18 Amps

UHF High Band 806-960 MHz PA8-1AA-RSF 1-3W 10-20W 5 AmpsPA8-1AB-RSF 1-3W 10-40W 10 AmpsPA8-1ED-RXRF 50mW-1W 40-80W 20 AmpsPA8-1AD-RXRF 1-5W 40-80W 16 AmpsPA8-1BD-RXRF 2-10W 40-80W 16 AmpsPA8-1DD-RXRF 4-20W 40-80W 16 AmpsPA8-2EF-RXRF 50mW-1W 60-125W 14 AmpsPA8-2AF-RXRF 1-4W 60-125W 12 AmpsPA8-2BF-RXRF 2-8W 60-125W 12 AmpsPA8-2DF-RXRF 4-15W 60-125W 12 Amps

*Input level must be specified at time of order.

**Operates off 28 VDC.

MODEL POWER IN POWER OUT CURRENT DRAIN

**

**

**

**

********

*

Page 6: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

SPECIFICATIONS

FEATURES

The Smart SRXRF-PS amplifiers contain all the features of our very popular RXR series of continuous duty power amplifiers. However, this new SMART unit has added features such as Controlled Output Level, Amplifier Protection, Local Failure Monitoring, and Outputs for Remote Monitoring. As with the RXR series, this amplifier will accept any TPL amplifier from VHF Low Band through 960 MHz, with output levels of up to 100 Watts. The unit uses 7” of vertical rack space and is designed for installation into a cabinet leaving sufficient room for airflow with the door closed. These amplifiers have a circuit breaker/on-off switch and five LED indicators, conveniently located on the front panel. Also, they are supplied with a self contained switching power supply. This is the most versatile unit of its type on the market today. Dimensions: 19” W x 7” H x 8” D. Wt. 15 lbs.

• Accommodates all bands from 29.7 MHz to 960 MHz• Feedback Controlled Output Level.• VSWR and Over Temperature Protection (Power Reduction)• Local Failure Monitoring.• LED indicators for: DC ON RF ON VSWR LOW POWER OVER TEMPERATURE• Forced air cooling• 100% duty Cycle• Repeater or Base Station operation (with solid state bypass relay option).• Front panel circuit breaker/on-off switch.• Flat front panel allows for cabinet door closure.• Cost effective design.

Power Input Standard TPL amplifier input levels, optional 10mW or less.Power Output Up to 100 Watts.Frequencies VHF Low Band, VHF High Band, UHF, 806-960 MHzVoltage 120 or 240 VAC Current 1-4 Amps AC @ 120 VACHarmonic Attenuation Exceeds FCC and IC specifications.RF Connectors Type N, 50 Ohms.Operating Temperature -30 to +50 degrees C.Duty Cycle Continuous (100%).Weight 15 lbs.Dimensions 19” W x 7” H x 8” D

SMART RXR6

Page 7: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

RF POWER AMPLIFIERS

VHF LOW BAND 29.7-50 MHzPA1-1AE-SRXRF-PS 4-6W 100WPA1-1BE-SRXRF-PS 6-10W 100WPA1-1CE-SRXRF-PS 12-20W 100WPA1-1DE-SRXRF-PS 25-40W 100WPA1-1FE- SRXRF-PS 40-60W 100W

VHF HIgH BAND 136-174 MHz PA3-1AE-SRXRF-PS 2-5W 100WPA3-1BE-SRXRF-PS 5-10W 100WPA3-1DE-SRXRF-PS 10-20W 100WPA3-1FE-SRXRF-PS 20-40W 100W

UHF 380-512 MHz All UHF units are available in two different sub-bands (M=400-470 MHz) (H=470-512 MHz)PA6-1AE-SRXRF-PS 4-8W 100W PA6-1BE-SRXRF-PS 10-20W 100W PA6-1DE-SRXRF-PS 20-40W 100W

UHF HIgH BAND 806-960 MHz PA8-1ED-SRXRF-PS 50mW-1W 80WPA8-1AD-SRXRF-PS 1-3W 80WPA8-1BD-SRXRF-PS 3-6W 80WPA8-1DD-SRXRF-PS 5-10W 80WPA8-2EF-SRXRF-PS 50mW-3W 125WPA8-2AF-SRXRF-PS 3-6W 125WPA8-2BF-SRXRF-PS 5-10W 125WPA8-2DF-SRXRF-PS 10-20W 125W

NOMINALMODEL POWER IN POWER OUT

*Input level must be specified at time of order.

*

*

Page 8: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

8

FEATURES

SPECIFICATIONS

The MAS (Multiple Amplifier Series) of RF Power Amplifiers is designed for system integrators. It is designed to house up to five vertical slide-in amplifiers in a 19” horizontal rack, while using only 7” of vertical rack space. This packaging system accepts any TPL amplifier from VHF Low Band through 960 MHz with output levels up to 125 Watts. Each amplifier module has a circuit breaker/on-off switch located on the front panel, along with two LED indicators for DC and RF Power, and two cooling fans. The rear panel has discrete connectors for RF and DC. Blind-mate D-SUB connectors for all connections are also available upon request. As an accessory, a power supply unit with the ability to house up to five power supplies is available in a 5 1/4” high by 19” wide rack mount enclosure (MAS-PS),with an additional 5 Amps DC auxiliary terminal available per power supply to power an exciter, etc.

• Capable of housing five slide-in units in a 19” rack mount configuration.• Accommodates all bands from 29.7 MHz to 960 MHz.• Forced air cooling with two thermostatically controlled fans for each amplifier module.• 100% duty cycle operation. • Trunking, Repeater, or base station operation (with solid state antenna switch relay option).• Front panel circuit breaker/on-off switch.• LED indicators for DC and RF Power.• Power Supply modules have Power On and Fault LED indicators and 5 Amps auxiliary terminals to power an exciter, etc.

MAS (Multiple Amplifier Series)

Power Input Standard TPL amplifier input levels, optional 10 mW or less.Power Output Up to 125 Watts.Frequencies VHF Low Band, VHF High Band, UHF, 806-960 MHz.Mode FM/CW (Linear available in some models).Voltage 13.8 VDC. 120 or 240 VAC with optional Power Supply.Current, DC Operation Model dependent.Current w/Optional Power Supply 15 Amps AC typical w/5 amplifiers at 100 Watts each, at 120 VAC.Harmonic & Spurious Attenuation Exceeds FCC and IC specifications.RF Connectors Type “N” or D-SUB Blind-mate (optional).In/Out Impedance 50 Ohms.Operating Temperature -30 to +50 degrees C.Duty Cycle Continuous (100%).Size, Amplifier Assembly 19” W x 7” H x 14” D (up to five modules).Size, Power Supply Assembly 19” W x 5 1/4” H x 15” D (up to five modules).Warranty Three years parts and labor.

Page 9: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

RF POWER AMPLIFIERS

VHF LOW BAND 29.7-50 MHz (L=29.7 - 36 MHz) (M=36-42 MHz) (H=42-50 MHz) PA1-1AE-MAS 2-4W 60-100WPA1-1BE-MAS 4-8W 60-100WPA1-1CE-MAS 8-16W 60-100WPA1-1DE-MAS 20-40W 60-100WPA1-1FE-MAS 40-60W 60-100W

VHF HIgH BAND 136-174 MHz PA3-1AE-MAS 1-5W 40-125WPA3-1BE-MAS 2-10W 40-125WPA3-1DE-MAS 5-25W 40-125WPA3-1FE-MAS 10-50W 40-125W

UHF BAND 380-512 MHz (M=400-470 MHz) (H=470-512 MHz)PA6-1AE-MAS 1-5W 40-110WPA6-1BE-MAS 2-10W 40-110WPA6-1DE-MAS 5-25W 40-110WPA6-1FE-MAS 10-50W 40-110W

UHF HIgH BAND 806-960 MHzPA8-1ED-MAS 50mW-1W 40-80W PA8-1DD-MAS 4-8W 40-80WPA8-1FD-MAS 15-30W 40-80W

One rack frame required per five amplifiers.*Input level must be specified at time of order.

NOMINALMODEL POWER IN POWER OUT

*

Page 10: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

10

FEATURES

SPECIFICATIONS

The SMART MAS amplifier series contains all the features of our very popular MAS series of continuous duty power amplifiers. However, this new SMART unit has added features such as Controlled Output Level, Amplifier Protection, Local Failure Monitoring, and Outputs for Remote Monitoring. As with the MAS series, this unit will accept any TPL amplifier from VHF Low Band through 960 MHz. It is designed to house up to five 100 Watt vertical slide-in amplifiers in a 19” horizontal rack, while using only 7” of vertical rack space. Each amplifier has a circuit breaker/on-off switch and LED indicators, conveniently located on the front panel for DC On, RF On, as well as for VSWR, Low Power, and Over Temperature Alarms. The rear panel has discrete connectors for RF and DC. Blind-mate D-SUB connectors are also available upon request. As an accessory, a power supply unit with the ability to house up to five power supplies is available in a 5 1/4” high by 19” wide, rack mount enclosure (MAS-PS), with an additional 5 Amps DC auxiliary terminal available per power supply to power an exciter, etc.

• Capable of housing five 100 Watt slide-in units in a 19” rack mount configuration.• Accommodates all bands from 29.7 MHz to 960 MHz.• Feedback Controlled Output Level.• VSWR and Over Temperature Protection (Power Reduction).• Local Failure Monitoring.• Outputs for Remote Monitoring.• LED indicators for:

DC ONRF ONVSWR LOW POWEROVER TEMPERATURE.

• Forced air cooling with two thermostatically controlled fans for each amplifier.• 100% duty cycle operation.• Trunking, Repeater, or Base Station operation (with antenna switch relay option).• Front panel circuit breaker/on-off switch.• Power Supply modules have Power On and Fault LED indicators and 5 Amps auxiliary terminals to power an exciter, etc.• Cost effective design.

Power Input Standard TPL amplifier input levels, optional 10 mW or less.Power Output Up to 100 Watts.Frequencies VHF Low Band, VHF High Band, UHF, 806-960 MHz.Mode FM/CW (Linear available in some models).Voltage 13.8 VDC. 120 or 240 VAC with optional Power Supply.Current, DC Operation 20 Amps DC per amplifier typical at 100 Watts.Current w/Optional Power Supply 15 Amps AC typical (w/5 amplifiers at 100 Watts each, at 120 VAC).Harmonic & Spurious Attenuation Exceeds FCC and IC specifications.RF Connectors Type “N”, or D-SUB Blind-mate (optional).In/Out Impedance 50 Ohms.Mismatch Capability 20:1 VSWR. Infinite on 800 MHz models if isolator option is selected.Operating Temperature -30 to +50 degrees C.Overtemp/VSWR Protection Gradual reduction of output power.Duty Cycle Continuous (100%).Size, Amplifier Assembly 19” W x 7” H x 14” D (up to five modules).Size, Power Supply Assembly 19” W x 5 1/4” H x 15” D (up to five power supply modules).Warranty Three years parts and labor.

SMART MAS

Page 11: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

RF POWER AMPLIFIERS

VHF LOW BAND 29.7-50 MHzPA1-1AE-SMAS 4-6W 100WPA1-1BE-SMAS 6-10W 100WPA1-1CE-SMAS 12-20W 100WPA1-1DE-SMAS 25-40W 100WPA1-1FE-SMAS 40-60W 100W

VHF HIgH BAND 136-174 MHz PA3-1AE-SMAS 2-5W 100WPA3-1BE-SMAS 5-10W 100WPA3-1DE-SMAS 10-20W 100WPA3-1FE-SMAS 20-40W 100W

UHF BAND 380-512 MHzPA6-1AE-SMAS 4-8W 100WPA6-1BE-SMAS 10-20W 100WPA6-1DE-SMAS 20-40W 100W

UHF HIgH BAND 806-960 MHzPA8-1ED-SMAS 50mW-3W 80W PA8-1AD-SMAS 3-6W 80WPA8-1BD-SMAS 5-10W 80WPA8-1DD-SMAS 10-20W 80W

One rack frame required per five amplifiers.*Input level must be specified at time of order.

*

NOMINALMODEL POWER IN POWER OUT

Page 12: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

12

FEATURES

SPECIFICATIONS

The LMS Ser ies of RF Power Ampl i f ier s i s des igned to provide medium power output leve l s up to 150 watts in the 29.7 MHz to 960 MHz range. It i s tota l ly se l f -conta ined with a regulated switching power supply, f ront panel meter for ampl i f ier monitor ing, three cool ing fans , and VSWR and temperature protect ion c i rcui t r y. It i s des igned for cont inuous duty operat ion in a 7” high rack-mount conf igurat ion.

• Fully enclosed compact package with power supply.• Double RF shielding for high RFI sites.• Digital meter monitoring for system evaluation and maintenance, including forward and reflected power.• High efficiency switching power supply. • Adjustable output power, feedback controlled.• Remote monitoring.• Adjustable alarm and protection thresholds.• VSWR protection/power reduction.• Over temperature protection/power reduction.• Alarms for low power, over temperature, VSWR, and fan failure.• Forced air cooling with three fans.• Convenient access for amplifier adjustments.• Excellent field serviceability.• Repeater or Base Station operation (with antenna switch relay option).

Power Input All TPL standard amplifier input levels from 50 mW to 40 watts. Lower input levels are optional.Power Output Up to 150 watts.Frequencies VHF Low Band, VHF High Band, UHF, 806-960 MHzMode FM/CW (Linear available in some models).Voltage 120 or 240 VAC. (Please specify)Current 1-4 Amps AC for various models.Harmonic & Spurious Attenuation Exceeds FCC requirements.RF Connectors BNC - Input, Type N - Output.In/Out Impedance 50 Ohms.Mismatch Capability 20:1 VSWR. Infinite on 800 MHz models if isolator option is selected.Remote Monitoring Overtemp, Low Power, Fan Failure, System Fault, Forward and Reflected Power, and other amplifier parameters.Local Monitoring Front panel digital display and LED indicators.Overtemp/VSWR Protection Gradual reduction of output power.Operating Temperature -30° to +50° C. AmbientDuty Cycle Continuous Weight 18 pounds.Dimensions 19” W x 7” H x 11” D.Warranty 3 years parts and labor.nty Three years parts and labor

LMS SERIES

Page 13: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

RF POWER AMPLIFIERS

VHF LOW BAND 29.7-50 MHzPA1-1AE-LMS 2-4W 100WPA1-1BE-LMS 4-8W 100WPA1-1CE-LMS 8-16W 100WPA1-1DE-LMS 20-40W 100W

VHF HIgH BAND 136-174 MHz PA3-2EE-LMS 500mW-2W 150WPA3-2AE-LMS 2-4W 150WPA3-2BE-LMS 4-8W 150WPA3-2DE-LMS 10-20W 150WPA3-2FE-LMS 20-40W 150W

UHF BAND 380-512 MHzPA6-2EE-LMS 250-500mW 125WPA6-2AE-LMS 1-2W 125WPA6-2AE3-LMS 2-4W 125WPA6-2AE6-LMS 4-8W 125WPA6-2BE-LMS 8-15W 125WPA6-2DE-LMS 15-20W 125W PA6-2FE-LMS 30-40W 125W

UHF HIgH BAND 806-960 MHzPA8-2EF-LMS 50mW-3W 125WPA8-2AF-LMS 2-4W 125WPA8-2BF-LMS 5-10W 125WPA8-2DF-LMS 10-20W 125W

NOMINALMODEL POWER IN POWER OUT

*Input level must be specified at time of order.

*

*

Page 14: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

14

FEATURES

SPECIFICATIONS

The HMS series is designed to provide high power output from VHF Low Band through 960MHz. It is manufac-tured for rugged use while combining the latest technology into a space efficient package. These units are totally self-contained with a regulated switching power supply, using only 10 1/2” of vertical rack space and 15” of depth. Internal circuitry monitors several parameters of the amplifier, including forward and reflected power.

Input and output connectors are located on the rear of the unit, making it convenient to connect coaxial cables. TPL has made the unit easy to service if necessary. The amplifier RF deck has all wiring contained in one harness, which can be easily disconnected, allowing only the RF deck to be removed for servicing. A new RF deck could be installed in a matter of minutes.

• Fully enclosed compact package with switching power supply.• Digital meter monitoring for system evaluation and maintenance, including forward and reflected power.• Adjustable output power, feedback controlled.• Alarms for low power, over temperature, VSWR, and fan failure.• VSWR protection/power reduction.• Over temperature protection/power reduction.• Adjustable alarm and protection thresholds.• Remote monitoring.• Forced air cooling with three fans.• Convenient access for amplifier adjustments.• Excellent field serviceability.• Repeater or base station operation (with coaxial antenna switch relay option).• Other bands and modes available on special order.

Power Input 75 mW to 70 Watts as specified.Power Outputs 300 Watts VHF Low Band (29.7-50MHz), 250 or 500 Watts VHF High Band (136-174MHz), 300 Watts UHF (406-512MHz), 250 Watts (806-960MHz).Mode FM/CW (Linear in some models).Voltage 120/240 VACCurrent 4 to 15 Amps AC, depending on model.Harmonic & Spurious Attenuation Exceeds FCC specifications.RF Connectors Type NIn/Out Impedance 50 OhmsMismatch Capability 20:1 VSWR. Infinite on 800 MHz models if isolator option is selected.Remote Monitoring Overtemp, Low Power, Fan Failure, System Fault, Forward and Reflected Power, and other amplifier parameters.Local Monitoring Front panel digital display and LED indicators.Overtemp/SWR Protection Gradual reduction of output power.Operating Temperature -30° to +50° degrees C. AmbientDuty Cycle Continuous Weight 45 pounds.Dimensions 19” W x 10 1/2” H x 15” D.Warranty 3 years parts and labor

HMS SERIES

Page 15: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

RF POWER AMPLIFIERS

VHF LOW BAND 35-50 MHzPA1-3AF-HMS 2-4W 300WPA1-3BF-HMS 4-8W 300WPA1-3CF-HMS 8-15W 300WPA1-3DF-HMS 15-25W 300WPA1-3FF-HMS 25-35W 300WPA1-3GF-HMS 35-70W 300W

VHF HIgH BAND 136-175 MHzPA3-2EF-HMS 500mW-1W 250WPA3-2AF-HMS 1-2W 250WPA3-2BF-HMS 2-4W 250WPA3-2CF-HMS 4-6W 250WPA3-2DF-HMS 8-12W 250WPA3-2FF-HMS 15-25W 250WPA3-2GF-HMS 30-50W 250W

PA3-2EG-HMS 1-2W 500WPA3-2AG-HMS 2-4W 500WPA3-2BG-HMS 4-8W 500WPA3-2CG-HMS 8-12W 500WPA3-2DG-HMS 15-25W 500WPA3-2FG-HMS 30-50W 500WPA3-2GG-HMS 60-100W 500W UHF BAND 400-512 MHz PA6-2EF-HMS 75-150mW 300WPA6-2BF-HMS 5-12W 300WPA6-2GF-HMS 20-45W 300W

UHF HIgH BAND 806-960 MHzPA8-2EG-HMS 10mW-1W 250WPA8-2BG-HMS 4-8mW 250WPA8-2CG-HMS 8-15mW 250W PA8-2DG-HMS 15-30W 250WPA8-2FG-HMS 30-60W 250W

*Input level must be specified at time of order.

*

*

*

NOMINALMODEL POWER IN POWER OUT

Page 16: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

16 MOBILE PACKAGE DIMENSIONS

TPL has been manufacturing mobile amplifiers since the company was founded in 1971. Over the years, this line has been greatly expanded and improved. TPL offers mobile amplifiers in the standard power outputs from as low as 10 Watts to as high as 125 Watts. Standard inputs range from as low as 1 Watt, to as high as 60 Watts. Special units can be ordered in practically any configuration.

• Standard voltage is 13.8 VDC. 28 Volts is available for most models.• Most mobile amplifiers may be tuned for broadband operation.• All items shown are standard – Please inquire for information on special designs, e.g.; low input drive, higher output, other frequencies.• UHF connectors are standard on all mobile amplifiers through 512 MHz. Type N connectors are standard on 806-960 MHz units. Other connectors are optional.• Solid State Carrier Operated Relays are standard in all mobile amplifiers.• All power specifications are nominal.• Specifications subject to change without notice.

FEATURES

Package a Package c Package D7.5” L x 2.2” H x 3.7” W 9.5” L x 3.0” H x 4.5” W 11.6” L x 3.0” H x 5.5” W

Page 17: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

RF POWER AMPLIFIERS

1. TPL Commercial Amplifiers are FCC Certified under Parts 22 and 90. In addition, some Amplifiers are also Industry Canada certified under RSS-131. Please include transmit frequency and input power to enable TPL to tune amplifier for optimum performance.

**Operates off 28 VDC.

MODEL POWER IN POWER OUT PACkAgE SIzE WEIgHT

VHF LOW BAND 29.7-50 MHz

PA1-1AC +/-1 MHz Bandwidth 1 - 4 W 10 - 40 W A 2 lbs.PA1-1AC3 +/-1 MHz Bandwidth 2 - 8 W 10 - 40 W A 2 lbs.PA1-1AE 2 - 4 W 60 - 100 W D 5 lbs.PA1-1BE 4 - 8 W 60 - 100 W D 5 lbs.PA1-1CE 8 - 16 W 60 - 100 W D 5 lbs.PA1-1DE 20 - 40 W 60 - 100 W D 5 lbs.PA1-1FE 40 - 60 W 60 - 100 W D 5 lbs.

VHF MID BAND 66-88 MHz PA2-1AD 1 - 4 W 60 - 100 W C 4 lbs.PA2-1CD 5 - 25 W 40 - 100 W C 4 lbs.

AERONAUTICAL BAND 118-137 MHz **PA3-2AB-AIR 1-5W CW 25W CW/100W PEP C 4 lbs. **PA3-2AC-AIR 1-5W CW 50W CW/200W PEP C 4 lbs.

VHF HIgH BAND 136-174 MHz PA3-1AC 1 - 5 W 15 - 60 W C 4 lbs.PA3-1BC 2 - 10 W 15 - 60 W C 4 lbs.PA3-1AE 1 - 5 W 40 - 125 W D 5 lbs.PA3-1BE 2 - 10 W 40 - 125 W D 5 lbs.PA3-1DE 5 - 25 W 40 - 125 W D 5 lbs.PA3-1FE 10 - 50 W 40 - 125 W D 5 lbs.

UHF 380-512 MHz PA6-1AC 1 - 5 W 15 - 60 W C 4 lbs.PA6-1BC 2 - 10 W 15 - 60 W C 4 lbs.PA6-1AE 1 - 5 W 40 - 110 W D 5 lbs.PA6-1BE 2 - 10 W 40 - 110 W D 5 lbs.PA6-1DE 5 - 25 W 40 - 110 W D 5 lbs.PA6-1FE 10 - 50 W 40 - 110 W D 5 lbs.

UHF HIgH BAND 806-960 MHz

PA8-1AA 1 - 3 W 10 - 20 W A 2 lbs.PA8-1AB 1 - 3 W 10 - 40 W C 4 lbs.PA8-1AD 1 - 5 W 40 - 80 W D 5 lbs.PA8-1BD 2 - 10 W 40 - 80 W D 5 lbs.PA8-1DD 4 - 20 W 40 - 80 W D 5 lbs.

All VHF High Band Amplifiers are broadband 136-174 MHz.

All of these mobile amplifiers have a minimum bandwidth of 15 MHz. Some units are available with 60 MHz bandwidth. Please inquire.

MOBILE AMPLIFIER

(For export only - not FCC or IC Certified)

All VHF Low Band Units with the exception of the PA1-1AC and PA1-1AC3 are available in three differ-ent sub-bands (L=29.7 - 36 MHz) (M=36 -42 MHz ) (H= 42-50 MHz)

All UHF units are available in two different sub-bands. (M=400-470 MHz) (H= 470-512 MHz)

Page 18: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

BASE STATION/REPEATER OPTIONS18

RSF Option Same as “RS” option but with a thermostatically controlled DC cooling fan to provide extra cooling up to 50 Watts. 19”W x 5 ¼”H x 4 ½” D. Wt. 8 lbs.

“RXRF” Option Same as “RXR” Option but with a thermostatically controlled DC cooling fan to provide extra cooling for units up to 150 watts. 19” W x 7” H x 5” D. WT 9 lbs. “RXRF-PS” Option “RXR” Option with continuous duty switching power supply and fan. 19” W x 7” H x 8” D. Wt. 13 lbs.

“RXHF3” Option This extra large rack mountable unit is designed for output application as follows: VHF up to 500 Watts, UHF up to 300 Watts, and 806-960 MHz up to 250 Watts. Thermostatically controlled cooling fans are standard. Optionally available with attached power supply. 19” W x 14” H x 7” D. Wt. 26 lbs.

Page 19: TPL History - RF Power Amplifiers, TPL Communications · Also, they are supplied with a self contained switching power supply. ... • Capable of housing five slide-in units in a

TPL’s Distributors

WarrantyTPL warrants that each product is free from defects in material and workmanship. If found to be defective within period specified below, the factory, at its discretion, will either repair or replace the unit at no cost, provided the unit is delivered by the owner to the factory intact, and if examination discloses, in the factory’s judgment, that it is defective under warranty. Units repaired under warranty will be returned prepaid. ALL TPL AMPLIFIERS SOLD AFTER JANUARY 1, 2013 CARRY A THREE-YEAR WARRANTY.

We reserve the right to alter specifications or design without notice. In Special critical applications, please consult with the manufacturer. This publication is used to provide an outline of specifications of the Products shown. It is not to form an order or contract or be regarded as a representation of the product unless agreed to in writing by the company.

TESSCO Technologies Inc. Global Logistics Center 11126 McCormick Road Hunt Valley, MD 21031 P 800-472-7373 F 410-527-0005 E-mail [email protected] www.tessco.com

HUTTON Communications, Inc. 2520 Marsh Lane Carrollton, TX 75006 P 877-648-8866 F 877-762-8274 E-mail [email protected] www.huttoncom.com

PRIMUS ELECTRONICS CORP. 4180 E. Sandridge Road Morris, IL 60450 P 800-435-1636 F 800-767-7605 E-mail [email protected] www.primuselectronics.com

VIkO Co., LTD 20 BI, 4 Panfilova Street Moscow, Russia 125080 www.viko.ru

RF Services, Inc. 442 Cadillac Parkway Dallas, GA 30157 P 865-483-0228 800-446-4969 RFPA/RB-Com 13 Place Pierre Curie F 33370 Artiques près Bordeaux France P: +33(0)5 56 86 85 84 F: +33(0)5 56 86 55 56

TALLEY COMMUNICATIONS 12976 Sandoval St. Santa Fe Springs, CA 90670 800.949.7079 P 562.906.8000 F 562.906.8080 E-mail [email protected] www.tallrycom.com

MOTOROLA, INC. 1301 E. Algonquin Rd. Schaumburg, IL 60196 800.422.4210 www.motorola.com

HYT AMERICA 3315 Commerce Parkway Miramar, FL 33025 800.845.1230 P 954.846.1011 F 954.846.1672 E-mail [email protected] www.hytera.com

Technical Equipment Dist., Inc. 4280 Dow Road, Ste. 102 Melbourne, FL 32934 P 321.259.2711 800.729.8334 E-mail [email protected] www.rfdistributor.com SYSCOM Av 20 de Noviembre No. 805 Chihuahua, Mexico P 011.52.614.415.2525 F 011.52.614.416.4298 www.syscom.com.mx

FABULOUS SYSTEMS SDN. BHD 19A, Jalan SS25/23 Tamal Plaza Malaysia

BENTRONIX LTD PO Box 2288 Neve-Monosson, 60190 Israel P 011.972.3.536039 F 011.972.8.5365781 E-mail [email protected] www.bentronix.co.il