tradition reliability quality year 2017 since 1921 · etd_presentation_eng 2017 [režim...
TRANSCRIPT
![Page 1: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/1.jpg)
TraditionReliability
Quality Since 1921Year 2017
![Page 2: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/2.jpg)
Present
Year 2017
![Page 3: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/3.jpg)
Organization Chart
Power Transformers,Including servisTurnover in 201615,2 mil. EUR
InternationalBEZ Group
Turnover in 201641,1 mil. EUR
ETDTRANSFORMERS
BEZTRANSFORMERS
ELECTRICALMACHINES
Repairs and servis of Transformers and rotating machinaryTurnover in 20163,9 mil. EUR
Distribution Transformers,Including repairs Turnover in 201622,0 mil. EUR
100 % 100 % 100 %
3
![Page 4: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/4.jpg)
UtilizationPower TransformersGeneration and transmission of electricity for great customes Output 6,3 MVA – 1 200 MVANominal voltage up to 420 kV
Distribution TransformersFor industry, villages and townsOutput 50 kVA – 10 MVANominal voltage up to 35 kV
TRANSMISSION DISTRIBUTION CONSUMPTIONPOWER GENERATION
4
![Page 5: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/5.jpg)
Our Customers
5
Mexico
Chile
![Page 6: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/6.jpg)
Company results
Year 2016
![Page 7: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/7.jpg)
Revenue progress since 2002(mil. CZK)
7
![Page 8: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/8.jpg)
Commodities in 2016
8
41%
35%
10%
8%6%
transformadores a 100 MVA
transformadores de 100 MVA
reactores
reparaciones
otros
![Page 9: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/9.jpg)
Our CertificationQuality Management System
acc.to EN ISO 9001Environmental Management System according to
EN ISO 14001
Metallic Materials Welded Bonds Requirements
according to EN ISO 3834-2
Electrotechnical Test Room Accreditation acc. to
EN ISO/IEC 17025Testing Activities of Test Room E 11 Qualification Certificate
Czech Railways Supplier Qualification Certificate
Pre-Qualification for Connexio System Supplier of Power Companies in Germany. Eastern and Central Europe
9
![Page 10: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/10.jpg)
10
Certificates Scope Issued by Valid to
1Certificate for the Quality Management System under EN ISO 9001:2008
Development, production, incl. testing, assembly and service of transformers and other electrical equipment
TÜV NORD 11.1.2018
2Certificate for the Environmental Management System under EN ISO 14001:2004
Development, production, incl. testing, assembly and service of transformers and other electrical equipment
TÜV NORD 11.1.2018
3Certificate for the Occupational Health and Safety Management System under BS OHSAS 18001:2007
Development, production, incl. testing, assembly and service of transformers and other electrical equipment
TÜV NORD 11.1.2018
4Certificate for the Welding Process under EN ISO 3834-2:2005
Designing and manufacturing of power transformers and other parts of vehicles which are not subject to the approval according to standards for railway – rail vehicles
TÜV NORD /
5Certificate of accreditation for Electrotechnical Testing Laboratory (L1526) under ČSN EN ISO/IEC 17025:2005
Electrical and air handling tests and measurements on industrial plant to the extent as specified in the attached appendix to the certificate.
The Czech Institute for
accreditation 1.7.2018
6Certificate of Competence for Testing Activities of the Test room E 11
Measurements and diagnostics of electrical non-rotational machines, analyses of insulating oils, tests ofinsulators and insulator sets, tests of HV metal-enclosed switchgear, tets of switchgear as specified in the attached appendix to the certificate.
Association of High Voltage
Testing Plants
31.10.2017
7Certificate of a Supplier’s Technical Competence for the Czech railways
All repairs, manufacturing and technical change of locomotive transformers, chokes and traction switches of electric locomotives
Czech railways /
8Certificat of pre-qualified supplier in system Connexio for utilities in Germany, Eastern and Central Europe
3.05.04 Transformers - generator3.05.28 Transformers 10 to 100 MVA3.05.29 Transformers above 100 MVA
Achilles Information
GmbH/
Our Certification summary
![Page 11: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/11.jpg)
Trade FairsIn 2017 we ´ll be pleased to welcome you at the following fairs :
• International Electronic and Electrotechnical Fair, AMPER.Brno, Czech Republic
• International Electrotechnical Fair Hannover Messe,Germany
• Middle East Electricity (MEE) Dubaj
• EXPO ELÉCTRICA, México
• POWER KAZACHSTAN
• Power&Electricity World Africa, Johannesburg
11
![Page 12: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/12.jpg)
Manufacturing Programme
Year 2017
![Page 13: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/13.jpg)
Three-phase Regulating Oil TransformersThree-phase regulating oil transformers with output from 10 to 320 MVAAnd non-regulating up to 410 MVA, nominal voltage up to 420 kV
Nuclear Power Plant Dukovany
13
13
![Page 14: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/14.jpg)
Three-Phase Non -Regulating Oil TransformersThree-phase non-regulating oil transformers with output up to 410 MVA and voltage up to 420 kV
300 MVA – JE Mochovce (3. a 4. blok)
14
![Page 15: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/15.jpg)
One-Phase Oil Transformers
One-phase oil transformerswith total output of a three-phase set up to 1200 MVA and voltage up to 420 kV
254/3 MVA Dalešice
15
![Page 16: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/16.jpg)
Special Transformers according to Customers Specifications
Regulating and non-regulating transformers according to individual customers specification with different types of winding, cooling and sizes.
Autotransformers with output up to 400 MVA and voltage 420 kV
25 MVA Actherm Chomutov
16
![Page 17: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/17.jpg)
Locomotive transformers
Locotransformers according to specific customerʼs requirements
Locotransformer for 62 E – 8108kVA, 25 kV
17
![Page 18: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/18.jpg)
Chokes
Chokes for rail vehicles – traction chokes
Choke CLVH 550-3m
ReactorsStarting reactors 6,3-22 kV, inductance up to 10 %
18
![Page 19: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/19.jpg)
Repairs, Modernization and Service
Repairs• Oil transformers with output from 1 to 400 MVA• Furnace transformers• Autotransformers
Technical Support• Transformer testing prior to commissioning
• Transformer Diagnostics
• Transformers Technical checkup
All activities are performed on transformers produc ed by ourselves as well as by other manufacturers.
19
![Page 20: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/20.jpg)
History
Year 2017
![Page 21: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/21.jpg)
Historical Milestonesof ETD Transformátory
1921 – establishment of Electrotechnical Engineering plant Škoda
1923 – first transformers 1150 kVAfor Elektrozavod in Prague
1950 – production of three-phase transformers 125 MVA, 220 kV
21
![Page 22: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/22.jpg)
Historical Milestones of ETD Transformátory1979 – one-phase transformers
570 MVA for Mělník 2 Power Plant
1985-86 – production of 6 pcs transformers 250 MVAfor Dukovany Power Plant
2000 – three-phase transformer410 MVA, 410/22 kVfor Kolubara Power Plant in Jugoslavia
22
![Page 23: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/23.jpg)
Historical Milestones of ETD Transformátory
23
2004 – New owner and name change
2005 – 2 pcs transformers 150 MVA for Egypt,5 pcs transformers 20 MVA for Cuba
2009 – 2 pcs transformers 300 MVA for Nuclear Power Plant Jaslovske Bohunice, SR
2011 – Dodání transformátorů pro projekt JE Mochovce 300 MVA, 63 MVA, 32 MVA
![Page 24: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/24.jpg)
Historical Milestones ofETD Transformátory
2014 – Three-phase autotransformer350 MVA, 400/121/34 kVfor Power plant Voľa, Slovakia
2015 – Transformers 2x185MVA; 2x8,25MVA for Mahmoudeia, Egypt
24
![Page 25: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/25.jpg)
Photographs• references
Year 2017
![Page 26: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/26.jpg)
Transformers ModernizationOne-phase transformer produced in Ukraine,
400 MVA, 420/24 kV after modernization and power increasing
26
One-phase transformers 220/3 MVA, 242/15/15 kVVE Orlík – year 2000
Transformer 25 MVA, 220/23 kVActherm Chomutov – year 2003
![Page 27: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/27.jpg)
Transformer 12,5 MVA, 110/27 kV for traction substation, Czech railways – year 2004
27
Transformer 63 MVA, 110/10,5 kVVřesová – year 2006
Transformer 25 MVA, 110/13,8 kVCuba – year 2007
![Page 28: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/28.jpg)
Transformer 300 MVA, 420/15,75 kVDukovany – year 2008
28
Saturating reactor electronically regulated Russia – year 2010
Regulated reactor for Cuba
![Page 29: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/29.jpg)
Transformer for electronic converters EN 6137851 MVA Metalworks in Strazske, Slovakia - 2010
29
One-phase transformer, 250 MVA, 420/21 kV for Power Plant Ledvice
Three-phase transformer 300 MVA, 420/15,75 kV For Nuclear Power Plant Mochovce, Slovakia
![Page 30: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/30.jpg)
NewsThree-phase autotransformer 350 MVA, 400/121/34 kV
for Electrical Plant Voľa, Slovakia - 2014
30
![Page 31: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/31.jpg)
News
31
Three-phase transform er 128MVA, 220/13,2 kV, Atacama, Chile - 2015
![Page 32: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/32.jpg)
News
32
Three-phase transformers 210MVA , 55MVA, 2x16MVA, México 2015
![Page 33: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/33.jpg)
Company Headquarters
ETD TRANSFORMÁTORY a.s.Zborovská 54/22301 00 PlzeňCzech Republic
Tel: +420 373 031 701Fax: +420 373 031 908E-mail: [email protected]
33
![Page 34: Tradition Reliability Quality Year 2017 Since 1921 · ETD_Presentation_ENG 2017 [režim kompatibility] Author: jan.korous Created Date: 3/16/2017 3:09:14 PM](https://reader034.vdocuments.net/reader034/viewer/2022050111/5f48475f49b0a46261572f4f/html5/thumbnails/34.jpg)
Thank you for your attention!
34