traditional feed gas & tail gas analyzers limitations · • traditional tail gas analysis:...

2
Traditional Feed Gas & Tail Gas Analyzers Limitations • Feed Forward Interferences: Slow & Highly Matrix Dependent • Multiple Acid Gas Streams: Expensive Monitoring Each Stream for Upsets • Traditional Tail Gas Analysis: Inefficiency From Long Process Lag Time Solution: Double Air Demand Tail Gas Analyzer Control • 2 Measurements: After First Condenser & End of Catalytic Stage (Tail Gas) • Robust Sample System: Handles Harsh Upstream Operating Conditions • 1 Control Strategy: Faster & More Accurate Air Demand Control NEW Double Air Demand (DAD) SRU Control Strategy [email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. April 2020 | Specifications Subject to Change Without Notice

Upload: others

Post on 05-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Traditional Feed Gas & Tail Gas Analyzers Limitations · • Traditional Tail Gas Analysis: Inefficiency From Long Process Lag Time Solution: Double Air Demand Tail Gas Analyzer Control

Traditional Feed Gas & Tail Gas Analyzers Limitations• Feed Forward Interferences: Slow & Highly Matrix Dependent• Multiple Acid Gas Streams: Expensive Monitoring Each Stream for Upsets• Traditional Tail Gas Analysis: Inefficiency From Long Process Lag Time

Solution: Double Air Demand Tail Gas Analyzer Control• 2 Measurements: After First Condenser & End of Catalytic Stage (Tail Gas)• Robust Sample System: Handles Harsh Upstream Operating Conditions• 1 Control Strategy: Faster & More Accurate Air Demand Control

NEW Double Air Demand (DAD)SRU Control Strategy

[email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. April 2020 | Specifications Subject to Change Without Notice

Page 2: Traditional Feed Gas & Tail Gas Analyzers Limitations · • Traditional Tail Gas Analysis: Inefficiency From Long Process Lag Time Solution: Double Air Demand Tail Gas Analyzer Control

NEW Double Air Demand (DAD)SRU Control Strategy

[email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. April 2020 | Specifications Subject to Change Without Notice

Brimstone™ 943-TGX

Brimstone = SRU CertaintyIn-Line Sulfur Condensing • Reduce Risk of Plugging

Close-Coupled • No Sample Line Plugging Issues

Custom Connections • For Variety of Existing Sample Port Sizes

Simple Operation • Only LP Steam & Air Utilities

COS & CS2 Trending • Monitor Catalyst Condition

Robust Sample System • For Challening Upstream Conditions

Note: Photo With Cabinet Doors Open

Double Air Demand (DAD) Advantage• Complete Solution: Control System Included With Analyzers • Faster Detection: Minimize SO2 Emissions Using Dual Full-Spectrum Analysis• Continuous Ratio Control: Double Your Analyzer Uptime