GA Drawing and Data sheet of 630kVA Distribution Transformer
02.06.2011 02.06.2011 02.06.2011G.S P.J VB
29.03.2011 29.03.2011 29.03.2011G.S P.J VB
PREPARED CHECKED APPROVED
E&I SUPPLIER Lotus Wireless Technologies India Pvt. Ltd., Visakhapatnam.
CLIENT Jindal Steel & Power Ltd.,Angul,Orissa
SUPPLIER Elecon Engineering Co. Ltd., Gujarat.
PROJECT Stacker cum Reclaimer ‐ 4
EQUIPMENT Stacker cum Reclaimer ‐1, 4 and 5 (HM483, HM484 and HM485)
TYPE / LOCATION Bucket Wheel Stacker cum Reclaimer
REVISED AS PER MECON COMMENTS
0 FIRST ISSUE FOR APPROVAL
REV. NO. DESCRIPTION
REVISIONS / ISSUE DATES
orm
atio
n tra
nsm
itted
by
this
doc
umen
t is
prop
rieta
ry a
nd c
onfid
entia
l pro
perty
of
and
may
not
1
Doc. No : LWT/BU5/TRF/HM483,HM484 & HM485 Rev. 01
The
info
Lotus Wireless Technologies 1 of 11 HM483,HM484 & HM485
6 Rating &Diagrm Plate 3 3CRT‐RD‐18820/c
G.A. of Marshalling Box & Wiring Diagram 3 3CRT‐MB‐18820/c
4 G.A. of L.V.Cable Box 3 3CRT‐LV‐18820/b
3 G.A. of H.V.Cable Box 3 3CRT‐HC‐18820/c
1 Transformer Data Sheet
VoltAmp
3 Annexure‐1
2 G.A. of Cast Resin Transformer 3 3CRT‐GA‐18820/d
5
not b
e du
plicated
disclosed
or utilized with
out w
ritten
con
sent from
INDEX
S.No Description Make Qty Ref. Drawings
E&I SUPPLIER Lotus Wireless Technologies India Pvt. Ltd., Visakhapatnam.
CLIENT Jindal Steel & Power Ltd.,Angul,Orissa
SUPPLIER Elecon Engineering Co. Ltd., Gujarat.
PROJECT Stacker cum Reclaimer ‐ 1
EQUIPMENT Stacker cum Reclaimer ‐1, 4 and 5 (HM483, HM484 and HM485)
TYPE / LOCATION Bucket Wheel Stacker cum Reclaimer
7 Quality Assurance Plane 3 Annexure‐2
mation transm
itted
by this docum
ent is prop
rietary and confiden
tial prope
rty of and
may
The inform
Lotus Wireless Technologies 2 of 11 HM483,HM484 & HM485
Annexure 1
Lotus Wireless Technologies 3 of 11 HM483,HM484 & HM485
Lotus Wireless Technologies 4 of 11 HM483,HM484 & HM485
Lotus Wireless Technologies 5 of 11 HM483,HM484 & HM485
Lotus Wireless Technologies 6 of 11 HM483,HM484 & HM485
Lotus Wireless Technologies 7 of 11 HM483,HM484 & HM485
Lotus Wireless Technologies 8 of 11 HM483,HM484 & HM485
Lotus Wireless Technologies 9 of 11 HM483,HM484 & HM485
Page : 1 of 2
Machine Cupplier : Elecon Engineering Co. Ltd., Gujarat QAP No.: E&I Supplier : Lotus Wireless Technologies India Pvt. Ltd., Chennai REV. No.: " 1 "P.O. No. : PO Dtd. 26.02.11 QTY : 03 Nos.Consultant : Mecon Ltd., Ranchi Date : 29.03.11Costomer / Project : Jindal Steel & Power Ltd., Angul, Orissa
SR.NO. ACTIVITIES CHARACTERISTIC TYPE OF EXTENT OF REFERENCE ACCEPTANCE INSPECTION BY REMARKSCHECK CHECK CHECK STANDARD STANDARD VTL CLIENT
1 RAW MATERIALS1.1 Enclosure Visual / Finish / Visual / Sample Approved Drg. Approved Drg. R
Dimensional Measurement
1.2 Lamination / CRGO Visual / Dimensional / Mechanical 100% Design Data Design Data RTC Review
1.3 Copper Visual / Dimensional / Mechanical Sample Design Data Design Data RInsulation Covering /TC Review
2 Inprocess Inspection
2.1 Enclosure Visual Dimensional Measurement 100% Approved Drg. Approved Drg. P
2.2 Core/ Winding / Insulation /Finish / Continuity / Visual / Test 100% Design Data Design Data PCasting Spacing
2.3 Termination & M.box Visual/Dimensional Visual/Wiring 100% Approved Drg. Approved Drg. PWiring Measurement
2.4 Bushings & bought outs TC review TC review 100% Approved Drg. Approved Drg. R
R = Records to be maintainedP = PerformW = Witness
Checked & Approved
Product: 630 kVA, 6.6 / 0.433 kV CAST RESIN DRY TYPE TRANSFORMER
Our Ref : 18820
VOLTAMP TRANSFORMERS LIMITEDJarod-Savli Road, Village-Vadadla, Taluka-Savli
District-Vadodara 391520, Gujarat, India
18820QUALITY ASSURANCE PLAN
Annexure 2
Lotus Wireless Technologies 10 of 11 HM483,HM484 & HM485
Page : 2 of 2
Machine Cupplier : Elecon Engineering Co. Ltd., Gujarat QAP No.: E&I Supplier : Lotus Wireless Technologies India Pvt. Ltd., Chennai REV. No.: " 1 "P.O. No. : PO Dtd. 26.02.11 QTY : 03 Nos.Consultant : Mecon Ltd., Ranchi Date : 29.03.11Costomer / Project : Jindal Steel & Power Ltd., Angul, Orissa
SR.NO. ACTIVITIES CHARACTERISTIC TYPE OF EXTENT OF REFERENCE ACCEPTANCE INSPECTION BY REMARKSCHECK CHECK CHECK STANDARD STANDARD VTL CLIENT
3 Final Inspection & Testing3.1 Routine tests Measurement of Electrical 100% IS 11171-1985 IS 11171-1985 P W
Winding resistance Or Latest Or Latest
Ratio & Vector check Electrical 100% IS 11171-1985 IS 11171-1985 P WOr Latest Or Latest
Measurement of % Electrical 100% IS 11171-1985 IS 11171-1985 P WImpedence & Load Loss Or Latest Or Latest
Measurement of No Electrical 100% IS 11171-1985 IS 11171-1985 P WLoad Loss & Current Or Latest Or Latest
Insulation resistance Electrical 100% IS 11171-1985 IS 11171-1985 P WOr Latest Or Latest
Induced Over Voltage Electrical 100% IS 11171-1985 IS 11171-1985 P Wwithstand test Or Latest Or Latest
Separate Source Electrical 100% IS 11171-1985 IS 11171-1985 P Wvoltage withstand test Or Latest Or Latest
R = Records to be maintainedP = PerformW = Witness
Checked & Approved
Our Ref : 18820
Product: 630 kVA, 6.6 / 0.433 kV CAST RESIN DRY TYPE TRANSFORMER
QUALITY ASSURANCE PLAN
Jarod-Savli Road, Village-Vadadla, Taluka-SavliDistrict-Vadodara 391520, Gujarat, India
18820
VOLTAMP TRANSFORMERS LIMITED
Lotus Wireless Technologies 11 of 11 HM483,HM484 & HM485