transitioning to version 8 building data entry issues in neat/mhea and

45
OAK RIDGE NATIONAL LABORATORY U. S. DEPARTMENT OF ENERGY 1 Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and Oak Ridge National Laboratory Weatherization Assistant Training Workshop

Upload: ariane

Post on 19-Mar-2016

48 views

Category:

Documents


0 download

DESCRIPTION

Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and. Oak Ridge National Laboratory Weatherization Assistant Training Workshop. The Weatherization Assistant. Umbrella program for NEAT and MHEA Version 7.4.3 (released August 12, 2003) - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY

1

Transitioning to Version 8 Building Data Entry Issues in

NEAT/MHEA and

Oak Ridge National Laboratory

Weatherization Assistant Training Workshop

Page 2: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

2

The Weatherization Assistant Umbrella program for NEAT and MHEA

Version 7.4.3 (released August 12, 2003) Version 8.6.0.4 (released November 9, 2009)

Purpose Identify for experienced users technical and

implementation changes made to NEAT and MHEA in Version 8

As time permits, highlight common data entry mistakes in using NEAT and MHEA pertinent to Versions 7 and 8

BUILDINGS TECHNOLOGY CENTEROAK RIDGE NATIONAL LABORAORY

Page 3: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

3

Transition Elements

Page 4: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

4

Main Menu Screen - Version 7

Page 5: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

5

Main Menu Screen - Version 8

Client information is entered separately from NEAT and MHEA house and file information

Page 6: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

Agency Information - Version 7

6

Page 7: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

Agency Information - Version 8

7

Page 8: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

Agency Contacts - Version 8

8

Page 9: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

9

General Information Tab - NEAT/MHEA Version 7

Typically started NEAT or MHEA by entering client, house, and file information on the General Information tab

Page 10: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

10

Main Menu Screen - Version 8

Client information is entered separately from NEAT and MHEA house and file information

Separate client main menu item

Page 11: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

11

Version 8Client Main Menu Item

Client information is entered before starting NEAT or MHEA

Page 12: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

12

Version 8Client Contacts Tab

Client Name is entered under separate Contacts tab under the Client Main Menu Item. More than one Contact can exist for a given Client record.

Page 13: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

13

Version 8Audit Information Tab - NEAT/MHEA

House and file information is entered on the Audit Information tab after starting NEAT or MHEA

Must now also link to Fuel Cost and Supply Libraries

Page 14: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

14

Navigation - NEAT/MHEAVersion 7

Version 8

New tabs for Version 8’s advanced features Audit record block to find files / Report block Shell forms organized under one Shell tab

Page 15: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

NEAT CHANGES

15

Page 16: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

16

Wall Tab – NEAT - Version 7

Windows and doors pertinent to the wall code are shown on the wall form

Page 17: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

17

Wall Tab – NEAT – Version 8

Windows and doors pertinent to the wall code are accessed by buttons

Comment button - links to comment editor

Page 18: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

18

Windows Tab – NEAT – Version 7

“Retrofit Status” renamed “Retrofit Options”. “Replace with Low-E” and “Evaluate None” added

Field replaced with Additional Cost fields for all retrofit options

Page 19: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

19

Windows Tab – NEAT – Version 8

Added Retrofit Options and replaced “Storm Cost” by “Additional Cost” fields for each option

Added yet un-useddescription fields

Page 20: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

20

Doors Tab – NEAT - Version 8

Clarified wording - optional and pertinent to door rather than storm door

Page 21: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

21

Version 8Unfinished Attics Tab - NEAT

Added R Value field allows specific insulation level to be analyzed (and no others)

Page 22: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

22

Finished Attics - NEAT

Version 7 Version 8

Version 8 allows for multiple finished attics segments of the same type

Page 23: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

23

Foundations – NEAT - Version 8

Reformatted form separates component types

Page 24: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

24

Foundations Tab - NEAT

Use Added Insulation Type fields to indicate what insulation measures are to be evaluated. Have added User-Defined Insulation Types.

Page 25: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

25

Heating Systems – NEAT - Version 8

Buttons access diagnostic input forms

Multiple heating systems allowed rather than just two - don’t need to heat 100%

Standard and high efficiency replacement equipment can be specified simultaneously

Page 26: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

26

Heating Systems – NEAT – Version 8

Page 27: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

27

Heating System Tab - NEAT “Optional [Evaluate All]” -

Allows NEAT to determine most cost-effective option, if any

“Tuneup Performed” Tells NEAT to

determine the most cost-effective of the remaining options, if any

Efficiency entered for existing system is the value after the tuneup

“Tuneup Mandatory”, “Standard-” and “High-” “Efficiency Replacement Mandatory”, Forces NEAT to recommend measure without considering other options even if not cost effective

“Don’t Replace”-Tells NEAT to not consider the two replacement options

“Evaluate None” – Evaluates no heating system options

Page 28: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

28

Heating Systems – NEAT - Version 8

Better ability to describe ducts for duct insulation measure

Page 29: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

29

Heating Tab – NEAT - Version 8

Secondary system can be combined with primary when considering replacement

Page 30: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

CHANGES IN BOTH NEAT AND MHEA

30

Page 31: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

31

Diagnostic Input Forms - NEAT/MHEA

Operational Tests Vent Tests

Page 32: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

32

Diagnostic Input Forms - NEAT/MHEA

Furnace Components Boiler Components

Page 33: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

33

Diagnostic Input Forms - NEAT/MHEA

Inspections Vent Tests

Page 34: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

34

Version 8Health and Safety Tab - NEAT/MHEA

Red box highlights health and safety items identified Checked items can be automatically entered as an Itemized Cost

New tab

Page 35: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

35

Version 8Health and Safety Tab - NEAT/MHEA

Page 36: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

36

Version 8Health and Safety Tab - NEAT/MHEA

Page 37: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

37

Version 8Itemized Costs Tab - NEAT/MHEA

“Description” now “Measure Name”

Fuel can now be chosen to be the same as the Primary Heating or Water Heating Fuel

Page 38: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

38

Version 8Itemized Costs Tab - NEAT/MHEA

Predefined measures can be selected. For example:

Page 39: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

39

Version 8Itemized Costs Tab - NEAT/MHEA

Or select from list of 50 hard-wired Health and Safety Measures. For example:

Page 40: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

40

Version 8Refrigerator Tab - NEAT/MHEA

New fields added, calculations shown, and two data bases accessed

Page 41: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

MHEA CHANGES

41

Page 42: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

42

Windows Tab – MHEA - Version 8

Leakiness field added

Retrofit options with Additional cost fields for each option added

Added yet un-useddescription field

Page 43: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

43

Floor Tab – MHEA - Version 8

“Attached to Joist” selection replaced with “Between Joists” and “Attached Under Joists”

Batt/Blanket Direction field removed

Page 44: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

44

Version 8 Floor Tab - MHEA

“Attached Under Joists” “Between Joists”

Page 45: Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and

45

Version 8Floor Tab (Addition) - MHEA

In Version 7, floors of additions described as if they were a mobile home type floor

In Version 8, Floor Type field added to describe more traditional floor types